Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
1.
BMC Public Health ; 24(1): 485, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360568

RESUMEN

BACKGROUND: In Ontario, Canada we developed and implemented an online screening algorithm for the distribution of HIV self-tests, known as GetaKit. During the COVID pandemic, we adapted the GetaKit algorithm to screen for COVID based on population and infection data and distributed COVID rt-LAMP self-tests (using the Lucira Check-It®) to eligible participants. METHODS: GetaKit/COVID was a prospective observational study that occurred over a 7-month period from September 2021 to April 2022. All potential participants completed an online registration and risk assessment, including demographic information, COVID symptoms and risk factors, and vaccination status. Bivariate comparisons were performed for three outcomes: results reporting status, vaccination status, and COVID diagnosis status. Data were analysed using Chi-Square for categorial covariates and Independent Samples T-Test and Mann-Whitney U test for continuous covariates. Bivariate logistic regression models were applied to examine associations between the covariates and outcomes. RESULTS: During the study period, we distributed 6469 COVID self-tests to 4160 eligible participants; 46% identified as Black, Indigenous or a Person of Colour (BIPOC). Nearly 70% of participants reported their COVID self-test results; 304 of which were positive. Overall, 91% also reported being vaccinated against COVID. Statistical analysis found living with five or fewer people, having tested for COVID previously, and being fully vaccinated were positive factors in results reporting. For COVID vaccination, people from large urban centers, who identified their ethnicity as white, and who reported previous COVID testing were more likely to be fully vaccinated. Finally, being identified as a contact of someone who had tested positive for COVID and the presence of COVID-related symptoms were found to be positive factors in diagnosis. CONCLUSIONS: While most participants who accessed this service were vaccinated against COVID and the majority of diagnoses were identified in participants who had symptoms of, or an exposure to, COVID, our program was able to appropriately link participants to recommended follow-up based on reported risks and results. These findings highlight the utility of online screening algorithms to provide health services, particularly for persons with historical barriers to healthcare access, such as BIPOC or lower-income groups.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/prevención & control , Ontario/epidemiología , Prueba de COVID-19 , Tamizaje Masivo/métodos , Vacunación
2.
Int J Mol Sci ; 25(11)2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38891951

RESUMEN

In the face of the SARS-CoV-2 pandemic, characterized by the virus's rapid mutation rates, developing timely and targeted therapeutic and diagnostic interventions presents a significant challenge. This study utilizes bioinformatic analyses to pinpoint conserved genomic regions within SARS-CoV-2, offering a strategic advantage in the fight against this and future pathogens. Our approach has enabled the creation of a diagnostic assay that is not only rapid, reliable, and cost-effective but also possesses a remarkable capacity to detect a wide array of current and prospective variants with unmatched precision. The significance of our findings lies in the demonstration that focusing on these conserved genomic sequences can significantly enhance our preparedness for and response to emerging infectious diseases. By providing a blueprint for the development of versatile diagnostic tools and therapeutics, this research paves the way for a more effective global pandemic response strategy.


Asunto(s)
COVID-19 , Biología Computacional , Secuencia Conservada , Genoma Viral , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , COVID-19/epidemiología , Humanos , Biología Computacional/métodos , Pandemias
3.
J Med Virol ; 95(8): e29022, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37565757

RESUMEN

While Mpox virus (MPXV) diagnostics were performed in specialized laboratories only, the global emergence of Mpox cases in 2022 revealed the need for a more readily available diagnostic. Automated random-access platforms with fast nucleic acid extraction and PCR have become established in many laboratories, providing faster and more accessible testing. In this study, we adapted a previously published generic MPXV-PCR as a lab-developed test (LDT) on a NeuMoDx Molecular System and isolated MPXV clones from patient materials. To reduce the handling of infectious material, we evaluated a viral lysis buffer (VLB) for sample pretreatment. We further compared the MPXV-LDT-PCR to conventional real-time PCR, determined its sensitivity and specificity using positive swabs, and assessed its performance using external quality assessment samples. Pretreatment of samples with 50% VLB reduced MPXV infectivity by approximately 200-fold while maintaining PCR sensitivity. The assay demonstrated a sensitivity and specificity of 100% with no cross-reactivity in the samples tested and performed with a limit of detection of 262 GE/mL. In summary, the assay had a turnaround time of fewer than 2 h and can easily be transferred to other automated PCR platforms, providing a basis for developing rapid assays for upcoming pandemics.


Asunto(s)
Monkeypox virus , Mpox , Técnicas de Amplificación de Ácido Nucleico , Humanos , Monkeypox virus/genética , Monkeypox virus/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Mpox/diagnóstico
4.
Transfusion ; 63 Suppl 3: S208-S212, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37067381

RESUMEN

BACKGROUND: The rapid provision of blood products is life-saving for patients with massive hemorrhage. Ideally, RhD-negative blood products would be supplied to a woman of childbearing potential whose Rh type is unknown due to the risk of D-alloimmunization and the potential for hemolytic disease of the fetus and newborn to occur if RhD-positive blood products are transfused. Therefore, there is a need for a test that rapidly determines her RhD type. This study compared the RhD type determined using a rapid ABO and RhD test to the RhD type determined by an immunohematology reference laboratory. METHODS: After receiving ethics review board approval, 200 random, unique, deidentified patient samples that had undergone routine pretransfusion testing in an immunohematology reference laboratory using column agglutination technology were collected and tested using a rapid ABO and RhD test (Eldoncard Home kit 2511). The RhD typing results from these two methods were compared to determine the accuracy of the rapid ABO and RhD test. RESULTS: The rapid ABO and RhD test produced results that were concordant with the transfusion service's results in 199/200 (99.5%) of cases, with a negative predictive value of 98.2% and 99.3% sensitivity. The single outlier was likely an RhD variant due to its serological characteristics. DISCUSSION: These data indicate that this rapid ABO and RhD test could be used for the rapid determination of a patient's RhD type, perhaps even in the emergency department, which could guide the selection of blood products provided during their resuscitation.


Asunto(s)
Bancos de Sangre , Enfermedades Hematológicas , Humanos , Femenino , Recién Nacido , Sistema del Grupo Sanguíneo Rh-Hr , Transfusión Sanguínea , Pruebas Hematológicas
5.
Rev Med Virol ; 32(5): e2350, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35348276

RESUMEN

Rapid antigen detection tests (RADTs) offer advantages over gold-standard reverse transcription polymerase chain reaction (RT-PCR) tests in that they are cheaper and provide faster results, thus enabling prompt isolation of positive SARS-CoV-2 cases and quarantine of close contacts. The aim of this study was to collate and synthesise empirical evidence on the effectiveness of rapid antigen testing for the screening (including serial testing) and surveillance of asymptomatic individuals to limit the transmission of SARS-CoV-2. A rapid review was undertaken in MEDLINE (EBSCO), EMBASE (OVID), Cochrane Library, Europe PMC and Google Scholar up until 19 July 2021, supplemented by a grey literature search. Of the identified 1222 records, 19 reports referring to 16 studies were included. Eight included studies examined the effectiveness of RADTs for population-level screening, four for pre-event screening and four for serial testing (schools, a prison, a university sports programme and in care homes). Overall, there is uncertainty regarding the effectiveness of rapid antigen testing for the screening of asymptomatic individuals to limit the transmission of SARS-CoV-2. This uncertainty is due to the inconsistent results, the relatively low number of studies identified, the predominantly observational and/or uncontrolled nature of the study designs used, and concerns regarding methodological quality. Given this uncertainty, more real-world research evidence in relevant settings, which is of good quality and timely, as well as economic evaluation, is required to inform public policy on the widespread use of RADTs in asymptomatic individuals.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Tamizaje Masivo , Estudios Observacionales como Asunto , Cuarentena
6.
Proc Natl Acad Sci U S A ; 117(47): 29518-29525, 2020 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-33148808

RESUMEN

The rapid spread of COVID-19 across the world has revealed major gaps in our ability to respond to new virulent pathogens. Rapid, accurate, and easily configurable molecular diagnostic tests are imperative to prevent global spread of new diseases. CRISPR-based diagnostic approaches are proving to be useful as field-deployable solutions. In one basic form of this assay, the CRISPR-Cas12 enzyme complexes with a synthetic guide RNA (gRNA). This complex becomes activated only when it specifically binds to target DNA and cleaves it. The activated complex thereafter nonspecifically cleaves single-stranded DNA reporter probes labeled with a fluorophore-quencher pair. We discovered that electric field gradients can be used to control and accelerate this CRISPR assay by cofocusing Cas12-gRNA, reporters, and target within a microfluidic chip. We achieve an appropriate electric field gradient using a selective ionic focusing technique known as isotachophoresis (ITP) implemented on a microfluidic chip. Unlike previous CRISPR diagnostic assays, we also use ITP for automated purification of target RNA from raw nasopharyngeal swab samples. We here combine this ITP purification with loop-mediated isothermal amplification and the ITP-enhanced CRISPR assay to achieve detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA (from raw sample to result) in about 35 min for both contrived and clinical nasopharyngeal swab samples. This electric field control enables an alternate modality for a suite of microfluidic CRISPR-based diagnostic assays.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , Sistemas CRISPR-Cas , Isotacoforesis/métodos , Microfluídica/métodos , Humanos , Mucosa Nasal/virología , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación
7.
J Dairy Sci ; 106(9): 6263-6274, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37500439

RESUMEN

The objective of this cross-sectional study was to standardize a reliable and repeatable swabbing technique using ATP luminometry (light emission proportional to the amount of ATP with result provided in relative light units [RLU]) to describe the cleanliness of various feeding equipment used for preweaning calves in dairy farms. A total of 7 Québec commercial dairy herds were selected conveniently. Following visual hygiene scoring, the cleanliness of every available piece of feeding equipment was assessed using direct surface swabbing for buckets and nipples with Hygiena UltraSnap swabs. A liquid rinsing technique was used for esophageal feeders, bottles, and automatic milk feeders (AMF) with UltraSnap, AquaSnap, and MicroSnap swabs. To validate direct swabbing technique of buckets, a stage within and between operators was realized, as well as a conventional bacterial culture. A total of 519 swab samples were obtained from 201 pieces of equipment. The median (interquartile range) contamination in RLU for a bottle, esophageal feeder, AMF, bucket and nipple was 2 (1;6), 2 (0;12), 52 (19;269), 886 (128;7,230) and 899 (142;6,928), respectively. The direct swabbing technique, which consists in swabbing directly the surface of an equipment, showed excellent correlation for intrarater reliability (intraclass correlation (ICC) = 0.93; 95% CI: 0.88-0.96). The interoperator (2 sessions with 3 different operators) reliability also showed high correlation (ICC = 0.88; 95% CI: 0.78-0.94 for the first session, and ICC = 0.89; 95% CI: 0.79-0.95 for the second session). Luminometer values were positively associated with the visual score of esophageal feeders, AMF and buckets. A positive correlation between bacterial culture and direct swabbing of buckets was also found for the UltraSnap (rs = 0.653; 95% CI: 0.283-0.873; P = 0.0003) and MicroSnap (rs = 0.569, 95% CI: 0.309-0.765; P = 0.002). This study describes a standardized and practical on-farm swabbing technique for assessing the hygienic status of feeding equipment by luminometry, which can be integrated in the investigation of preweaning dairy calves problems.


Asunto(s)
Industria Lechera , Leche , Animales , Bovinos , Estudios Transversales , Reproducibilidad de los Resultados , Industria Lechera/métodos , Leche/microbiología , Estándares de Referencia , Adenosina Trifosfato , Destete
8.
Molecules ; 28(12)2023 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-37375311

RESUMEN

BACKGROUND: Isoniazid is a leading tuberculosis treating medication. Global supply chains provide essential medicines such as isoniazid to resource-limited areas. Ensuring the safety and efficaciousness of these medicines is essential to public health programs. Handheld spectrometers are becoming increasingly approachable in cost and usability. As supply chains expand, quality compliance screening of essential medications is necessary in site-specific locations. Here, a brand-specific qualitative discrimination analysis of isoniazid is approached by collecting data from two handheld spectrometers in two countries with the intent to build a multi-location quality compliance screening method for a brand of isoniazid. METHODS: Two handheld spectrometers (900-1700 nm) were used to collect spectra from five manufacturing sources (N = 482) in Durham, North Carolina, USA, and Centurion, South Africa. A qualitative brand differentiation method was established from both locations by applying a Mahalanobis distance thresholding method as a measure of assessing similarity. RESULTS: Combining data from both locations resulted in a 100% classification accuracy, at both locations, for brand 'A' and resulted in the four other brands classifying as dissimilar. Bias was found between sensors in terms of resulting Mahalanobis distances, but the classification method proved to be robust enough to accommodate. Several spectral peaks found in isoniazid references appear within the 900-1700 nm range, as well as variation in the excipients per manufacturer. CONCLUSIONS: Results show promise for compliance screening isoniazid as well as other tablets in multiple geographic locations using handheld spectrometers.


Asunto(s)
Isoniazida , Espectroscopía Infrarroja Corta , Espectroscopía Infrarroja Corta/métodos , Calibración , Comprimidos , Sudáfrica
9.
Appl Environ Microbiol ; 88(5): e0174021, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34985977

RESUMEN

Throughout the coronavirus disease 2019 (COVID-19) pandemic, wastewater surveillance has been used to monitor trends in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) prevalence in the community. A major challenge in establishing wastewater surveillance programs, especially in remote areas, is the need for a well-equipped laboratory for sample analysis. Currently, no options exist for rapid, sensitive, mobile, and easy-to-use wastewater tests for SARS-CoV-2. The performance of the GeneXpert system, which offers cartridge-based, rapid molecular clinical testing for SARS-CoV-2 in a portable platform, was evaluated using wastewater as the input. The GeneXpert demonstrated a SARS-CoV-2 limit of detection in wastewater below 32 copies/mL with a sample processing time of less than an hour. Using wastewater samples collected from multiple sites across Canada during February and March 2021, a high overall agreement (97.8%) was observed between the GeneXpert assay and laboratory-developed tests regarding the presence or absence of SARS-CoV-2. Additionally, with the use of centrifugal filters, the detection threshold of the GeneXpert system was improved to <10 copies/mL in wastewater. Finally, to support on-site wastewater surveillance, GeneXpert testing was implemented in Yellowknife, a remote community in Northern Canada, where its use successfully alerted public health authorities to undetected transmission of COVID-19. The identification of SARS-CoV-2 in wastewater triggered clinical testing of recent travelers and identification of new COVID-19 cases/clusters. Taken together, these results suggest that GeneXpert is a viable option for surveillance of SARS-CoV-2 in wastewater in locations that do not have access to established testing laboratories. IMPORTANCE Wastewater-based surveillance is a powerful tool that provides an unbiased measure of COVID-19 prevalence in a community. This work describes a sensitive wastewater rapid test for SARS-CoV-2 based on a widely distributed technology, the GeneXpert. The advantages of an easy-to-use wastewater test for SARS-CoV-2 are clear: it supports surveillance in remote communities, improves access to testing, and provides faster results allowing for an immediate public health response. The application of wastewater rapid testing in a remote community facilitated the detection of a COVID-19 cluster and triggered public health action, clearly demonstrating the utility of this technology. Wastewater surveillance will become increasingly important in the postvaccination pandemic landscape as individuals with asymptomatic/mild infections continue transmitting SARS-CoV-2 but are unlikely to be tested.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiología , Humanos , Pandemias , Aguas Residuales , Monitoreo Epidemiológico Basado en Aguas Residuales
10.
J Med Virol ; 94(7): 3070-3080, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35218042

RESUMEN

Our study aim was to evaluate the performance of the automated Sysmex HISCL® severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen assay against reverse-transcription polymerase chain reaction (RT-PCR). We tested 277 remnant frozen nasopharyngeal swab samples, stored in universal transport medium (UTM), yielding a sensitivity of 94.9% against historical RT-PCR results with cycle threshold (Ct ) < 30, and a sensitivity of 76.7% for Ct < 35, and specificity of 100% (all Ct values) confirming compatibility of UTM-diluted samples with the assay system. Thereafter, we prospectively collected 141 nasopharyngeal swab samples in UTM from healthcare workers and 1369 paired swabs (400 UTM; 969 dry) from individuals at a public health testing center, with the first swab (UTM) reserved for RT-PCR, yielding a positivity rate of 4.6%. HISCL assay performance using UTM swabs was superior to dry swabs, with a sensitivity of 100% (95% confidence interval [CI] 71.5%-100%) at Ct < 30 versus 92.3% (95%CI 81.5%-97.9%), and a specificity of 99.3% (95% CI 98.1-99.89) against 83.3% (95%CI 80.7%-85.6%). We conclude that this antigen assay is suitable for high throughput facilities where the primary indication for testing is to rule out infection with low RT-PCR Ct values (proxy for high viral loads) to curb viral spread.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Nasofaringe , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/genética , Sensibilidad y Especificidad
11.
Br J Clin Pharmacol ; 88(9): 4163-4170, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35419830

RESUMEN

AIMS: Glucose-6-phosphate dehydrogenase (G6PD) deficiency, the most common enzymopathy in humans, can cause acute haemolysis resulting from exposure to certain medications, chemicals, infections and fava beans. Rasburicase, used to manage elevated uric acid levels in the oncologic emergency of tumour lysis syndrome, is one such drug. The US Food and Drug Administration (FDA) recommends testing of G6PD status prior to rasburicase administration for patients at higher risk for G6PD deficiency. METHODS: We performed a retrospective chart review of all oncology patients for whom a semi-quantitative biochemical test for detecting G6PD deficiency was performed prior to rasburicase administration over a 2.5-year period, in a large academic metropolitan hospital. RESULTS: We identified 16 out of 260 tested individuals as G6PD-deficient (6.1%), including six females. On average, test results were electronically available to health care providers within 4 hours of sample collection, with most results available within 2-3 hours. Four G6PD-deficient patients developed elevated uric acid levels. Two of the G6PD-deficient patients were treated with rasburicase, and subsequently developed haemolysis, which was appropriately managed. CONCLUSION: In summary, by providing information about G6PD status with a rapid turnaround time, we have taken a significant step towards personalized medicine in our institution. In spite of the test implementation, two out of four G6PD-deficient patients, who were no longer candidates for rasburicase use, still received the drug, highlighting the need for improved provider education.


Asunto(s)
Deficiencia de Glucosafosfato Deshidrogenasa , Urato Oxidasa , Femenino , Deficiencia de Glucosafosfato Deshidrogenasa/complicaciones , Deficiencia de Glucosafosfato Deshidrogenasa/diagnóstico , Hemólisis , Humanos , Estudios Retrospectivos , Centros de Atención Terciaria , Urato Oxidasa/administración & dosificación , Urato Oxidasa/efectos adversos , Ácido Úrico
12.
Arch Sex Behav ; 51(4): 2015-2025, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35449365

RESUMEN

Cisgender men who have sex with men (cMSM) and transgender women (TGW) are disproportionally burdened by HIV. Among these populations, HIV partner-testing is a highly acceptable harm reduction tool. Particularly, cMSM and TGW report a stronger preference for blood-based tests that include assays for multiple STIs. However, no existing research has explored how these populations negotiate blood-based testing with sexual partners. In the SMARTtest study, 48 sexually active cMSM and TGW took home dual, blood-based HIV/Syphilis kits for self- and partner-testing. After 3 months, they completed a follow-up assessment and in-depth interviews about their experiences initiating testing. Of the 42 responding participants, 27 (64%) reported that it had been "fairly" or "very easy" to raise the idea of testing with partners. Participants predominantly employed partner-conscious communication strategies, including framing the testing proposal as a mandatory, non-personal component of their participation in a research study, gradually incorporating testing mentions into discussions about sexual health, and using the kits to facilitate joint testing. Yet, 21 (44%) participants reported having sex with at least one partner they did not ask to test. Concern regarding partner reactions emerged as a significant barrier to discussing test use; similarly, many partners were averse to taking a blood-based test in the context of a casual sexual encounter. Nonetheless, these findings suggest that dual, blood-based HIV/STI rapid tests may represent acceptable harm reduction tools among similar populations of cMSM and TGW, particularly if future partner-testing research is broadened to consider key couples' dynamics that may impact test usage.


Asunto(s)
Infecciones por VIH , Minorías Sexuales y de Género , Enfermedades de Transmisión Sexual , Sífilis , Personas Transgénero , Femenino , Infecciones por VIH/diagnóstico , Homosexualidad Masculina , Humanos , Masculino , Negociación , Ciudad de Nueva York , Conducta Sexual , Parejas Sexuales , Sífilis/diagnóstico
13.
BMC Public Health ; 22(1): 588, 2022 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-35337297

RESUMEN

BACKGROUND: Antigen testing using lateral flow devices (LFDs) plays an important role in the management of the novel coronavirus pandemic of 2019 (COVID-19) by rapidly identifying individuals who are asymptomatically carrying high levels of the virus. By January 2021, LFD community testing sites were set up across English local authority areas to support the management and containment of regional COVID-19 cases, initially targeting essential workers unable to work from home during the national lockdown. This study aimed to examine the characteristics and motivations of individuals accessing community LFD testing across two local authority areas (LAAs) in the South West of England. METHODS: Data were collected as part of a service evaluation from December 22nd 2020 until March 15th 2021 for two LAAs. Demographic and postcode data were collected from an online test appointment booking platform and the National Health Service testing service online system, with data accessed from Public Health England. An online survey was sent to individuals who made a testing appointment at an LAA1 site using the online booking platform, consisting of 12 questions to collect data on individual's motivations for and experiences of testing. RESULTS: Data were available for individuals who completed 12,516 tests in LAA1 and 12,327 tests in LAA2. Most individuals who engaged with testing were female, working age, white, and worked as early years or education staff, health and social care staff, and supermarket or food production staff. 1249 individuals completed the survey with 60% of respondents reported getting tested for work-related reasons. Individuals first heard about LFD testing through various channels including work, media, and word of mouth, and decided to get tested based on the ease and convenience of testing, workplace communications, and to identify asymptomatic cases to help stop the spread. Most tests were completed by individuals living in less deprived areas based on national deciles of deprivation. CONCLUSIONS: While national and local COVID-19 testing strategies have evolved, community and personal LFD testing remains a crucial pillar of the testing strategy. Future studies should collect quantitative and qualitative data from residents to most effectively shape testing offers based on the needs and preferences of their population.


Asunto(s)
COVID-19 , Motivación , COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de COVID-19 , Control de Enfermedades Transmisibles , Femenino , Humanos , Medicina Estatal
14.
BMC Pediatr ; 22(1): 533, 2022 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-36076181

RESUMEN

BACKGROUND: In-home direct antigen rapid testing (DART) plays a major role in COVID-19 mitigation and policy. However, perceptions of DART within high-risk, intellectually impaired child populations are unknown. This lack of research could negatively influence DART uptake and utility among those who stand to benefit most from DART. The purpose of this study was to describe caregivers' perceptions of an in-home COVID-19 DART regimen in children with medical complexity, including the benefits and limitations of DART use. METHODS: This qualitative study was a subproject of the NIH Rapid Acceleration of Diagnostics Underserved Populations research program at the University of Wisconsin. We combined survey data and the thematic analysis of semi-structured interview data to understand caregivers' perceptions of in-home COVID-19 testing and motivators to perform testing. Caregivers of children with medical complexity were recruited from the Pediatric Complex Care Program at the University of Wisconsin (PCCP). Data were collected between May and August 2021. RESULTS: Among n = 20 caregivers, 16/20 (80%) of their children had neurologic conditions and 12/20 (60%) used home oxygen. Survey data revealed that the largest caregiver motivators to test their child were to get early treatment if positive (18/20 [90%] of respondents agreed) and to let the child's school know if the child was safe to attend (17/20 [85%] agreed). Demotivators to testing included that the child could still get COVID-19 later (7/20 [35%] agreed), and the need for officials to reach out to close contacts (6/20 [30%] agreed). From interview data, four overarching themes described perceptions of in-home COVID-19 testing: Caregivers perceived DART on a spectrum of 1) benign to traumatic and 2) simple to complex. Caregivers varied in the 3) extent to which DART contributed to their peace of mind and 4) implications of test results for their child. CONCLUSIONS: Although participants often described DART as easy to administer and contributing to peace of mind, they also faced critical challenges and limitations using DART. Future research should investigate how to minimize the complexity of DART within high-risk populations, while leveraging DART to facilitate safe school attendance for children with medical complexity and reduce caregiver burden.


Asunto(s)
COVID-19 , Cuidadores , COVID-19/diagnóstico , Prueba de COVID-19 , Niño , Familia , Humanos , Investigación Cualitativa
15.
J Dairy Sci ; 105(2): 1638-1648, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34802728

RESUMEN

The objective of this observational cross-sectional study was to describe the cleanliness of various equipment used for colostrum harvest and calf feeding procedures on dairy farms in Québec, Canada. The study was performed on 42 commercial dairy herds also enrolled in another study aiming to determine the transfer of passive immunity over a 14-mo period. Information on colostrum quality (using Brix value) and cleanliness (total aerobic and total coliform count) were recorded as well as various practices focused on colostrum-feeding equipment and preweaning period using a standard questionnaire. During the study period, colostrum and milk-feeding equipment cleanliness was assessed using direct surface swabbing with Hygiena Ultrasnap swabs. A total of 155 swab samples were obtained from 6 pieces of equipment. Adenosine triphosphate collected from the swabbed surface reacts with the luciferase solution present in the swab by bioluminescence, which is proportional to the quantity of ATP present and quantified as relative light units (RLU). The description of feed equipment cleanliness (defined as the maximal RLU found for a specific herd, dichotomized as <1,000 RLU vs. ≥1,000 RLU) was compared with the herds' descriptive characteristics, focusing on the first 2 components of a multiple correspondence analysis. The median (range) RLU for buckets used for colostrum harvest, bucket or bottle used for feeding, tube feeders, milking colostrum line, and internal surface of the nipples were 41 RLU (3-1,625 RLU), 78 RLU (<1-3,765 RLU), 29 RLU (<1-2,177 RLU), 83 RLU (<1-9,968 RLU), and 1,101 RLU (2-9,546 RLU), respectively. The first 2 components of multiple correspondence analysis explained 24.7% of data variances and were related to the farms' hygiene and health (13.0%) and feeding practices (11.7% of data variance). The maximal dichotomized luminometry value (<1,000 RLU or ≥1,000 RLU) was associated with hygiene and health dimension. This study gave promising results concerning the potential application of ATP luminometry for calf rearing practices assessment.


Asunto(s)
Calostro , Industria Lechera , Adenosina Trifosfato , Animales , Granjas , Femenino , Leche , Embarazo
16.
Sensors (Basel) ; 21(2)2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33418986

RESUMEN

Rapid diagnostic tests (RDTs) are often used for the detection of anti-human immunodeficiency virus (HIV) antibodies in remote locations in low- and middle-income countries (LMIC) with low or limited access to central laboratories. The typical format of an RDT is a lateral flow assay (LFA) with visual interpretation prone to subjectivity. This risk of misinterpretation can be overcome with luminescent upconverting nanoparticle reporters (UCNPs) measured with a miniaturized easy-to-use reader instrument. An LFA with UCNPs for anti-HIV-1/2 antibodies was developed and the assay performance was evaluated extensively with challenging patient sample panels. Sensitivity (n = 145) of the UCNP-LFA was 96.6% (95% CI: 92.1-98.8%) and specificity (n = 309) was 98.7% (95% CI: 96.7-99.7%). Another set of samples (n = 200) was used for a comparison between the UCNP-LFA and a conventional visual RDT. In this comparison, the sensitivities for HIV-1 were 96.4% (95% CI: 89.8-99.3%) and 97.6% (95% CI: 91.6-99.7%), for the UCNP-LFA and conventional RDT, respectively. The specificity was 100% (95% CI: 96.4-100%) for both assays. The developed UCNP-LFA demonstrates the applicability of UCNPs for the detection of anti-HIV antibodies. The signal measurement is done by a reader instrument, which may facilitate automated result interpretation, archiving and transfer of data from de-centralized locations.


Asunto(s)
VIH-1 , Nanopartículas , Anticuerpos , Humanos , Inmunoensayo , Pruebas Inmunológicas , Sensibilidad y Especificidad
17.
Am J Transplant ; 20(11): 3106-3112, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32476285

RESUMEN

Universal screening of potential organ donors and recipients for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is now recommended prior to transplantation in the United States during the coronavirus disease 19 (COVID-19) pandemic. Challenges have included limited testing capacity, short windows of organ viability, brief lead time for notification of potential organ recipients, and the need to test lower respiratory donor specimens to optimize sensitivity. In an early U.S. epicenter of the outbreak, we designed and implemented a system to expedite this testing and the results here from the first 3 weeks. The process included a Laboratory Medicine designee for communication with organ recovery and transplant clinical staff, specialized sample labeling and handoff, and priority processing. Thirty-two organs recovered from 14 of 17 screened donors were transplanted vs 70 recovered from 23 donors during the same period in 2019. No pretransplant or organ donors tested positive for SARS-CoV-2. Median turnaround time from specimen receipt was 6.8 hours (donors), 6.5 hours (recipients): 4.5 hours faster than daily inpatient median. No organ recoveries or transplantations were disrupted by a lack of SARS-CoV-2 testing. Waitlist inactivations for COVID-19 precautions were reduced in our region. Systems that include specialized ordering pathways and adequate testing capacity can support continued organ transplantation, even in a SARS-CoV-2 hyperendemic area.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Tamizaje Masivo/métodos , Trasplante de Órganos , Pandemias , SARS-CoV-2 , Receptores de Trasplantes , COVID-19/epidemiología , Estudios de Seguimiento , Humanos , Estudios Retrospectivos , Donantes de Tejidos/estadística & datos numéricos
18.
J Clin Microbiol ; 58(12)2020 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-32967898

RESUMEN

Seasonal influenza virus is associated with high morbidity and mortality especially in vulnerable patient populations. Here, we demonstrate the novel use of Sofia influenza A+B fluorescent immunoassay (FIA), a rapid antigen-based influenza point-of-care test (POCT), combined with Virena software for automatic deidentified tracking of influenza activity across the Los Angeles area and for predicting surges of influenza cases in the emergency department (ED). We divided outpatient clinics into 6 geographic zones and compared weekly influenza activity. In the outpatient setting, there were 1,666 and 274 influenza A and influenza B positives, respectively, across the 2018 to 2019 influenza season and 1,857 and 1,449 influenza A and influenza B positives, respectively, during the 2019 to 2020 influenza season, with zone-specific differences observed. Moreover, we found that a rapid increase in outpatient influenza was followed by an influx in influenza-positive cases in the ED, offering a 1- to 3-week warning sign for ED influx of triple or quadruple the number of influenza cases compared to the prior week. Sofia influenza A+B FIA allows for surveillance of real-time deidentified influenza activity. Tracking of such data may serve as a valuable region-specific influenza indicator and predictor to guide infection prevention measures in both the outpatient and hospital settings. High-impact interventions include designating areas for waiting rooms for influenza-like illnesses, altering staff scheduling in anticipation of surges, and securing sufficient personal protective equipment and antivirals during the height of influenza season.


Asunto(s)
Prestación Integrada de Atención de Salud , Gripe Humana , Servicio de Urgencia en Hospital , Humanos , Gripe Humana/diagnóstico , Los Angeles/epidemiología , Pacientes Ambulatorios
19.
Virol J ; 17(1): 160, 2020 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-33087160

RESUMEN

BACKGROUND: Fast, reliable and easy to handle methods are required to facilitate urgently needed point-of-care testing (POCT) in the current coronavirus pandemic. Life-threatening severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has rapidly spread all over the world, infecting more than 33,500,000 people and killing over 1 million of them as of October 2020. Infected individuals without any symptoms might still transfer the virus to others underlining the extraordinary transmissibility of this new coronavirus. In order to identify early infections effectively, treat patients on time and control disease spreading, rapid, accurate and onsite testing methods are urgently required. RESULTS: Here we report the development of a loop-mediated isothermal amplification (LAMP) based method to detect SARS-CoV-2 genes ORF8 and N directly from pharyngeal swab samples. The established reverse transcription LAMP (RT-LAMP) assay detects SARS-CoV-2 directly from pharyngeal swab samples without previous time-consuming and laborious RNA extraction. The assay is sensitive and highly specific for SARS-CoV-2 detection, showing no cross reactivity when tested on 20 other respiratory pathogens. The assay is 12 times faster and 10 times cheaper than routine reverse transcription real-time polymerase chain reaction, depending on the assay used. CONCLUSION: The fast and easy to handle RT-LAMP assay amplifying specifically the genomic regions ORF8 and N of SARS-CoV-2 is ideally suited for POCT at e.g. railway stations, airports or hospitals. Given the current pandemic situation, rapid, cost efficient and onsite methods like the here presented RT-LAMP assay are urgently needed to contain the viral spread.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/virología , Neumonía Viral/virología , Animales , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Chlorocebus aethiops , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Genes Virales , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico/métodos , Pandemias , Neumonía Viral/diagnóstico , Sistemas de Atención de Punto , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Transcripción Reversa , SARS-CoV-2 , Células Vero
20.
J Community Health ; 45(6): 1228-1235, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32651767

RESUMEN

HIV rapid testing algorithms (RTAs) using any two orthogonal rapid tests (RTs) allow for on-site confirmation of infection. RTs vary in performance characteristics therefore the selection of RTs in an algorithm may affect identification of infection, particularly if acute. National HIV Behavioral Surveillance (NHBS) assessed RTAs among men who have sex with men recruited using anonymous venue-based sampling. Different algorithms were evaluated among participants who self-reported never having received a positive HIV test result prior to the interview. NHBS project areas performed sequential or parallel RTs using whole blood. Participants with at least one reactive RT were offered anonymous linkage to care and provided a dried blood spot (DBS) for testing at CDC. Discordant results (RT-1 reactive/RT-2 non-reactive) were tested at CDC with lab protocols modified for DBS. DBS were also tested for HIV-1 RNA (VL) and antiretroviral (ARV) drug levels. Of 6500 RTAs, 238 were RT-1 reactive; of those, 97.1% (231/238) had concordant results (RT-1/RT-2 reactive) and 2.9% (7/238) had discordant results. Five DBS associated with discordant results were available for confirmation at CDC. Four had non-reactive confirmatory test results that implied RT-1 false reactivity; one had ambiguous confirmatory test results which was non-reactive in further testing. Regardless of order and type of RT used, RTAs demonstrated high concordant results in the population surveyed. Additional laboratory testing on DBS following discordant results confirmed no infection. Implementing RTAs in the context of anonymous venue-based HIV testing could be an option when laboratory follow-up is not practicable.


Asunto(s)
Infecciones por VIH/epidemiología , Prueba de VIH/métodos , Adulto , Algoritmos , Homosexualidad Masculina , Humanos , Masculino , Minorías Sexuales y de Género
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda