Magn Reson Med ; 91(2): 649-659, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37815020

RESUMEN

PURPOSE: To develop an efficient and flexible water/fat separated real-time MRI (RT-MRI) method using spiral out-in-out-in (OIOI) sampling and balanced SSFP (bSSFP) at 0.55T. METHODS: A bSSFP sequence with golden-angle spiral OIOI readout was developed, capturing three echoes to allow water/fat separation. A low-latency reconstruction that combines all echoes was available for online visualization. An offline reconstruction provided water and fat RT-MRI in two steps: (1) image reconstruction with spatiotemporally constrained reconstruction (STCR) and (2) water/fat separation with hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (HIDEAL). In healthy volunteers, spiral OIOI was acquired in the wrist during a radial-to-ulnar deviation maneuver, in the heart without breath-hold and cardiac gating, and in the lower abdomen during free-breathing for visualizing small bowel motility. RESULTS: We demonstrate successful water/fat separated RT-MRI for all tested applications. In the wrist, resulting images provided clear depiction of ligament gaps and their interactions during the radial-to-ulnar deviation maneuver. In the heart, water/fat RT-MRI depicted epicardial fat, provided improved delineation of epicardial coronary arteries, and provided high blood-myocardial contrast for ventricular function assessment. In the abdomen, water-only RT-MRI captured small bowel mobility clearly with improved water-fat contrast. CONCLUSIONS: We have demonstrated a novel and flexible bSSFP spiral OIOI sequence at 0.55T that can provide water/fat separated RT-MRI with a variety of application-specific temporal resolution and spatial resolution requirements.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Agua , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Corazón , Respiración
2.
Magn Reson Med ; 92(1): 15-27, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38501903

RESUMEN

Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.


Asunto(s)
Imagen por Resonancia Magnética , Movimiento (Física) , Humanos , Imagen por Resonancia Magnética/métodos , Termometría/métodos , Termografía/métodos , Algoritmos , Hipertermia Inducida , Artefactos
3.
Behav Res Methods ; 56(3): 2623-2635, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37507650

RESUMEN

Real-time magnetic resonance imaging (rtMRI) is a technique that provides high-contrast videographic data of human anatomy in motion. Applied to the vocal tract, it is a powerful method for capturing the dynamics of speech and other vocal behaviours by imaging structures internal to the mouth and throat. These images provide a means of studying the physiological basis for speech, singing, expressions of emotion, and swallowing that are otherwise not accessible for external observation. However, taking quantitative measurements from these images is notoriously difficult. We introduce a signal processing pipeline that produces outlines of the vocal tract from the lips to the larynx as a quantification of the dynamic morphology of the vocal tract. Our approach performs simple tissue classification, but constrained to a researcher-specified region of interest. This combination facilitates feature extraction while retaining the domain-specific expertise of a human analyst. We demonstrate that this pipeline generalises well across datasets covering behaviours such as speech, vocal size exaggeration, laughter, and whistling, as well as producing reliable outcomes across analysts, particularly among users with domain-specific expertise. With this article, we make this pipeline available for immediate use by the research community, and further suggest that it may contribute to the continued development of fully automated methods based on deep learning algorithms.


Asunto(s)
Laringe , Canto , Humanos , Imagen por Resonancia Magnética/métodos , Laringe/diagnóstico por imagen , Laringe/anatomía & histología , Laringe/fisiología , Habla/fisiología , Boca/anatomía & histología , Boca/fisiología
4.
Magn Reson Med ; 90(3): 839-851, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37154407

RESUMEN

PURPOSE: Conventional sequences are static in nature, fixing measurement parameters in advance in anticipation of a wide range of expected tissue parameter values. We set out to design and benchmark a new, personalized approach-termed adaptive MR-in which incoming subject data is used to update and fine-tune the pulse sequence parameters in real time. METHODS: We implemented an adaptive, real-time multi-echo (MTE) experiment for estimating T2 s. Our approach combined a Bayesian framework with model-based reconstruction. It maintained and continuously updated a prior distribution of the desired tissue parameters, including T2 , which was used to guide the selection of sequence parameters in real time. RESULTS: Computer simulations predicted accelerations between 1.7- and 3.3-fold for adaptive multi-echo sequences relative to static ones. These predictions were corroborated in phantom experiments. In healthy volunteers, our adaptive framework accelerated the measurement of T2 for n-acetyl-aspartate by a factor of 2.5. CONCLUSION: Adaptive pulse sequences that alter their excitations in real time could provide substantial reductions in acquisition times. Given the generality of our proposed framework, our results motivate further research into other adaptive model-based approaches to MRI and MRS.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Teorema de Bayes , Imagen por Resonancia Magnética/métodos , Simulación por Computador , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen
5.
Childs Nerv Syst ; 39(12): 3457-3466, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37261536

RESUMEN

PURPOSE: Pineal region cysts (PCs) may affect the tectum and aqueduct and cause deep central vein congestion. Beside headaches, PC often causes a broad range of symptoms, leading to prolonged diagnosis and therapy. The aims of this study are to reveal parameters that might explain the ambiguity of the symptoms and to identify factors in association with the respiration-driven neurofluid system. METHODS: This retrospective study included 28 paediatric patients (mean age 11.6 years) who received surgical treatment and 18 patients (mean age 11.3 years) who were followed conservatively. Symptoms, time to diagnosis, cyst size, ventricular indices, head circumference and postoperative outcome, were analysed. Four patients were investigated for CSF dynamics with real-time MRI. The mean follow-up time was 1.6 years. RESULTS: The most common early onset symptoms were headaches (92%), blurred vision (42.8%), sleep disturbances (39.3%) and vertigo (32.1%). Tectum contact was observed in 82% of patients, and MRI examinations revealed that imaging flow void signals were absent in 32.1% of patients. The maximal cyst diameters were 13.7 × 15.6 mm (mean). Together with a postoperative flow void signal, 4 patients recovered their respiration-driven CSF aqueductal upward flow, which was not detectable preoperatively. After surgery the main symptoms improved. CONCLUSION: Despite proximity to the aqueduct with frequently absent flow void signals, hydrocephalus was never detected. Data from real-time MRI depicted a reduced preoperative filling of the ventricular CSF compartments, indicating a diminished fluid preload, which recovered postoperatively.


Asunto(s)
Neoplasias Encefálicas , Quistes del Sistema Nervioso Central , Quistes , Hidrocefalia , Glándula Pineal , Humanos , Niño , Estudios Retrospectivos , Neoplasias Encefálicas/complicaciones , Quistes del Sistema Nervioso Central/cirugía , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/etiología , Hidrocefalia/cirugía , Quistes/complicaciones , Imagen por Resonancia Magnética/métodos , Cefalea/etiología , Glándula Pineal/diagnóstico por imagen , Glándula Pineal/cirugía
6.
Magn Reson Med ; 87(6): 2741-2756, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35081262

RESUMEN

PURPOSE: To develop a real-time radial tagging MRI for accurate measurement of rotational motion and twist of the left ventricle (LV). METHODS: A FLASH-based radial tagging sequence with an undersampled radial reading scheme was developed for both single and double-slice imaging in real-time. The Polar Fourier Transform was used for reconstruction to push the undersampling artifacts out of a reduced FOV. The developed technique was used to image five normal subjects during rest, plus one during both exercise and rest conditions. LV rotational motions were estimated for five consecutive cardiac cycles in all cases. The process was validated using a numerical phantom. The real-time measurement of global rotational motion was compared with those measured from a non-real-time exam using linear regression analysis and the Bland-Altman plot. RESULTS: The real-time acquisition was performed successfully with a temporal resolution of 46.2 ms. Image quality was sufficient for the reproducible calculation of rotation at rest and exercise. The feasibility of double-slice acquisition on human was further studied and a real-time twist of the left ventricle was demonstrated. The difference between LV global rotations from real-time and non-real-time approaches was 0.27 degrees. A significant reverse recoiling, induced by exercise, was reproducibly measured by the technique. CONCLUSION: A real-time radial tagging MRI technique was developed based on the undersampled radial acquisition and Polar Fourier Transform reconstruction, for accurate measuring of the heart rotational motion and twist. The technique was able to extract a meaningful change of diastolic recoiling under stress test conditions during physical activities (cycling).


Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Magnética , Diástole , Corazón , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
7.
Magn Reson Med ; 87(4): 1863-1875, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34850452

RESUMEN

PURPOSE: To develop an auto-calibrated image reconstruction for highly accelerated multi-directional phase-contrast (PC) MRI that compensates for (1) reconstruction instabilities occurring for phase differences near ± π and (2) phase errors by concomitant magnetic fields that differ for individual radial spokes. THEORY AND METHODS: A model-based image reconstruction for real-time PC MRI based on nonlinear inversion is extended to multi-directional flow by exploiting multiple flow-encodings for the estimation of velocity vectors. An initial smoothing constraint during iterative optimization is introduced to resolve the ambiguity of the solution space by penalizing phase wraps. Maxwell terms are considered as part of the signal model on a line-by-line basis to address phase errors by concomitant magnetic fields. The reconstruction methods are evaluated using simulated data and cross-sectional imaging of a rotating-disc, as well as in vivo for the aortic arch and cervical spinal canal at 3T. RESULTS: Real-time three-directional velocity mapping in the aortic arch is achieved at 1.8 × 1.8 × 6 mm3 spatial and 60 ms temporal resolution. Artificial phase wraps are avoided in all cases using the smoothness constraint. Inter-spoke differences of concomitant magnetic fields are effectively compensated for by the model-based image reconstruction with integrated radial Maxwell correction. CONCLUSION: Velocity vector reconstructions based on nonlinear inversion allow for high degrees of radial data undersampling paving the way for multi-directional PC MRI in real time. Whether a spoke-wise treatment of Maxwell terms is required or a computationally cheaper frame-wise approach depends on the individual application.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Algoritmos , Aorta Torácica , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos
8.
J Magn Reson Imaging ; 55(1): 81-99, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33295674

RESUMEN

Real-time magnetic resonance imaging (RT-MRI) allows for imaging dynamic processes as they occur, without relying on any repetition or synchronization. This is made possible by modern MRI technology such as fast-switching gradients and parallel imaging. It is compatible with many (but not all) MRI sequences, including spoiled gradient echo, balanced steady-state free precession, and single-shot rapid acquisition with relaxation enhancement. RT-MRI has earned an important role in both diagnostic imaging and image guidance of invasive procedures. Its unique diagnostic value is prominent in areas of the body that undergo substantial and often irregular motion, such as the heart, gastrointestinal system, upper airway vocal tract, and joints. Its value in interventional procedure guidance is prominent for procedures that require multiple forms of soft-tissue contrast, as well as flow information. In this review, we discuss the history of RT-MRI, fundamental tradeoffs, enabling technology, established applications, and current trends. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Imagen por Resonancia Magnética
9.
Neurourol Urodyn ; 41(5): 1074-1081, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35419817

RESUMEN

PURPOSE: Few studies have examined the effects of body position on urination efficiency morphologically. We aimed to dissect out the anatomical changes of pelvic organs during urination in the upright and supine positions by a real-time magnetic resonance imaging (rtMRI) system. METHODS: Thirteen healthy male volunteers aged 26-60 years were included in the study. The sagittal real-time two-dimensional images were taken to evaluate urinary efficiency, along with change in six morphological indices at the time of storage and the beginning of voiding, in both upright ant supine positions. RESULTS: Urination was more efficient in upright position than in supine position, as expressed by higher average rate of bladder emptying (9.9 ± 4.2 vs. 6.8 ± 2.9 ml/s, p < 0.05) and also by fewer participants showing significant residual urine (1/13 vs. 7/13, p < 0.05). At the onset of voiding in standing position, the levator ani (LA) muscle moves downward and backward followed by descent of the bladder neck and rotation of the prostate around the symphysis. Such changes were expressed by two morphological indices. One was posterior vesicourethral angle at the start of voiding, 152 ± 7 versus 140 ± 1 in upright and supine position (p < 0.05). The other index was the change in angle between the LA line and pubo-coccygeal line in upright and supine position, 9.4 ± 9.9 versus 1.6 ± 7.9 before voiding (p < 0.05) and 30.2 ± 14.0 versus 17.3 ± 12.9 after the start of voiding (p < 0.05). CONCLUSION: The dynamic relaxation of LA seemed to be a key movement that enables more efficient urination in standing position than in supine position.


Asunto(s)
Posición de Pie , Micción , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Postura/fisiología , Posición Supina/fisiología , Micción/fisiología
10.
Magn Reson Med ; 86(2): 916-925, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33728700

RESUMEN

PURPOSE: To mitigate a common artifact in spiral real-time MRI, caused by aliasing of signal outside the desired FOV. This artifact frequently occurs in midsagittal speech real-time MRI. METHODS: Simulations were performed to determine the likely origin of the artifact. Two methods to mitigate the artifact are proposed. The first approach, denoted as "large FOV" (LF), keeps an FOV that is large enough to include the artifact signal source during reconstruction. The second approach, denoted as "estimation-subtraction" (ES), estimates the artifact signal source before subtracting a synthetic signal representing that source in multicoil k-space raw data. Twenty-five midsagittal speech-production real-time MRI data sets were used to evaluate both of the proposed methods. Reconstructions without and with corrections were evaluated by two expert readers using a 5-level Likert scale assessing artifact severity. Reconstruction time was also compared. RESULTS: The origin of the artifact was found to be a combination of gradient nonlinearity and imperfect anti-aliasing in spiral sampling. The LF and ES methods were both able to substantially reduce the artifact, with an averaged qualitative score improvement of 1.25 and 1.35 Likert levels for LF correction and ES correction, respectively. Average reconstruction time without correction, with LF correction, and with ES correction were 160.69 ± 1.56, 526.43 ± 5.17, and 171.47 ± 1.71 ms/frame. CONCLUSION: Both proposed methods were able to reduce the spiral aliasing artifacts, with the ES-reduction method being more effective and more time efficient.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Habla
11.
Magn Reson Med ; 85(6): 3182-3195, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33452722

RESUMEN

PURPOSE: To provide 3D real-time MRI of speech production with improved spatio-temporal sharpness using randomized, variable-density, stack-of-spiral sampling combined with a 3D spatio-temporally constrained reconstruction. METHODS: We evaluated five candidate (k, t) sampling strategies using a previously proposed gradient-echo stack-of-spiral sequence and a 3D constrained reconstruction with spatial and temporal penalties. Regularization parameters were chosen by expert readers based on qualitative assessment. We experimentally determined the effect of spiral angle increment and kz temporal order. The strategy yielding highest image quality was chosen as the proposed method. We evaluated the proposed and original 3D real-time MRI methods in 2 healthy subjects performing speech production tasks that invoke rapid movements of articulators seen in multiple planes, using interleaved 2D real-time MRI as the reference. We quantitatively evaluated tongue boundary sharpness in three locations at two speech rates. RESULTS: The proposed data-sampling scheme uses a golden-angle spiral increment in the kx -ky plane and variable-density, randomized encoding along kz . It provided a statistically significant improvement in tongue boundary sharpness score (P < .001) in the blade, body, and root of the tongue during normal and 1.5-times speeded speech. Qualitative improvements were substantial during natural speech tasks of alternating high, low tongue postures during vowels. The proposed method was also able to capture complex tongue shapes during fast alveolar consonant segments. Furthermore, the proposed scheme allows flexible retrospective selection of temporal resolution. CONCLUSION: We have demonstrated improved 3D real-time MRI of speech production using randomized, variable-density, stack-of-spiral sampling with a 3D spatio-temporally constrained reconstruction.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Habla , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Estudios Retrospectivos , Lengua/diagnóstico por imagen
12.
Magn Reson Med ; 83(5): 1652-1658, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31670850

RESUMEN

PURPOSE: To develop a rapid and motion-robust technique for volumetric MRI, which is based on cross-sectional real-time MRI acquisitions with automatic advancement of the slice position. METHODS: Real-time MRI with a frame-by-frame moving cross-section is performed with use of highly undersampled radial gradient-echo sequences offering spin density, T1 , or T2 /T1 contrast. Joint reconstructions of serial images and coil sensitivity maps from spatially overlapping sections are accomplished by nonlinear inversion with regularization to the preceding section-formally identical to dynamic real-time MRI. Shifting each frame by 20% to 25% of the section thickness ensures 75% to 80% overlap of successive sections. Acquisition times of 40 to 67 ms allow for rates of 15 to 25 sections per second, while volumes are defined by the number of cross-sections times the section shift. RESULTS: Preliminary realizations at 3T comprise studies of the human brain, carotid arteries, liver, and prostate. Typically, coverage of a 90- to 180-mm volume at 0.8- to 1.2-mm in-plane resolution, 4- to 6-mm section thickness, and 0.8- to 1.5-mm section shift is accomplished within total measuring times of 4 to 6 seconds and a section speed of 15 to 37.5 mm per second. However, spatiotemporal resolution, contrast including options such as fat saturation and total measuring time are highly variable and may be adjusted to clinical needs. Promising volumetric applications range from fetal MRI to dynamic contrast-enhanced MRI. CONCLUSION: The proposed method allows for rapid and motion-robust volume coverage in a variety of imaging scenarios.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Estudios Transversales , Humanos , Masculino , Movimiento (Física)
13.
Magn Reson Med ; 84(2): 838-846, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31872918

RESUMEN

OBJECTIVES: To evaluate a novel method for real-time tagged MRI with increased tag persistence using phase sensitive tagging (REALTAG), demonstrated for speech imaging. METHODS: Tagging is applied as a brief interruption to a continuous real-time spiral acquisition. REALTAG is implemented using a total tagging flip angle of 180° and a novel frame-by-frame phase sensitive reconstruction to remove smooth background phase while preserving the sign of the tag lines. Tag contrast-to-noise ratio of REALTAG and conventional tagging (total flip angle of 90°) is simulated and evaluated in vivo. The ability to extend tag persistence is tested during the production of vowel-to-vowel transitions by American English speakers. RESULTS: REALTAG resulted in a doubling of contrast-to-noise ratio at each time point and increased tag persistence by more than 1.9-fold. The tag persistence was 1150 ms with contrast-to-noise ratio >6 at 1.5T, providing 2 mm in-plane resolution, 179 frames/s, with 72.6 ms temporal window width, and phase sensitive reconstruction. The new imaging window is able to capture internal tongue deformation over word-to-word transitions in natural speech production. CONCLUSION: Tag persistence is substantially increased in intermittently tagged real-time MRI by using the improved REALTAG method. This makes it possible to capture longer motion patterns in the tongue, such as cross-word vowel-to-vowel transitions, and provides a powerful new window to study tongue biomechanics.


Asunto(s)
Lenguaje , Imagen por Resonancia Magnética , Fenómenos Biomecánicos , Habla , Lengua/diagnóstico por imagen
14.
Magn Reson Med ; 84(6): 3438-3452, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32710516

RESUMEN

PURPOSE: To develop and evaluate a fast and effective method for deblurring spiral real-time MRI (RT-MRI) using convolutional neural networks. METHODS: We demonstrate a 3-layer residual convolutional neural networks to correct image domain off-resonance artifacts in speech production spiral RT-MRI without the knowledge of field maps. The architecture is motivated by the traditional deblurring approaches. Spatially varying off-resonance blur is synthetically generated by using discrete object approximation and field maps with data augmentation from a large database of 2D human speech production RT-MRI. The effect of off-resonance range, shift-invariance of blur, and readout durations on deblurring performance are investigated. The proposed method is validated using synthetic and real data with longer readouts, quantitatively using image quality metrics and qualitatively via visual inspection, and with a comparison to conventional deblurring methods. RESULTS: Deblurring performance was found superior to a current autocalibrated method for in vivo data and only slightly worse than an ideal reconstruction with perfect knowledge of the field map for synthetic test data. Convolutional neural networks deblurring made it possible to visualize articulator boundaries with readouts up to 8 ms at 1.5 T, which is 3-fold longer than the current standard practice. The computation time was 12.3 ± 2.2 ms per frame, enabling low-latency processing for RT-MRI applications. CONCLUSION: Convolutional neural networks deblurring is a practical, efficient, and field map-free approach for the deblurring of spiral RT-MRI. In the context of speech production imaging, this can enable 1.7-fold improvement in scan efficiency and the use of spiral readouts at higher field strengths such as 3 T.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Artefactos , Humanos , Imagen por Resonancia Magnética , Redes Neurales de la Computación
15.
Magn Reson Med ; 83(6): 2343-2355, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31722119

RESUMEN

PURPOSE: MRI-guided cardiovascular intervention using standard metal guidewires can produce focal tissue heating caused by induced radiofrequency guidewire currents. It has been shown that safe operation is made possible by using parallel transmit radiofrequency coils driven in the null current mode, which does not induce radiofrequency currents and hence allows safe tissue visualization. We propose that the maximum current modes, usually considered unsafe, be used at very low power levels to visualize conductive wires, and we investigate pulse sequences best suited for this application. METHODS: Spoiled gradient echo, balanced steady-state free precession, and turbo spin echo sequences were evaluated for their ability to visualize a conductive guidewire embedded in a gel phantom when run in maximum current modes at very low power level. Temperature at the guidewire tip was monitored for safety assessment. RESULTS: Excellent guidewire visualization could be achieved using maximum current modes excitation, with the turbo spin echo sequence giving the best image quality. Although turbo spin echo is usually considered to be a high-power sequence, our method reduced all pulses to 1% amplitude (0.01% power), and heating was not detected. In addition, visualization of background tissue can be achieved using null current mode, also with no recorded heating at the guidewire tip even when running at 100% (reported) specific absorption rate. CONCLUSION: Parallel transmit is a promising approach for both guidewire and tissue visualization using maximum and null current modes, respectively, for interventional cardiac MRI. Such systems can switch excitation mode instantaneously, allowing for flexible integration into interactive sequences.


Asunto(s)
Imagen por Resonancia Magnética Intervencional , Imagen por Resonancia Magnética , Diseño de Equipo , Fantasmas de Imagen , Ondas de Radio
16.
NMR Biomed ; 33(4): e4232, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31913551

RESUMEN

Recent MRI studies of blood flow in the inferior vena cava (IVC) resulted in findings which are inconsistent with earlier observations by invasive procedures - most likely because ECG-gated MRI techniques are unable to resolve dynamic adjustments due to respiration. The purpose of this work was to apply real-time phase-contrast MRI at 50 ms resolution to re-evaluate IVC flow in response to normal and deep breathing as well as breath holding and Valsalva maneuver (11 young healthy subjects). Real-time flow MRI relied on highly undersampled radial gradient-echo sequences and a model-based nonlinear inverse reconstruction. A frequency analysis of the predominant pulsatility classified IVC flow in individual subjects as "cardiac", "respiratory" or "mixed" type. Peak flow velocities during free breathing ranged from 30 to 58 cm s-1 , while flow rates varied from 15 to 37 ml s-1 . The subject-specific IVC flow pattern persists during deep breathing although the enhanced respiratory influence may shift subjects form "cardiac" to "mixed" or from "mixed" to "respiratory" type. Peak velocities increased relative to normal breathing but led to similar flow rates of 16 to 34 ml s-1 . Inspiration during deep breathing elicited brief periods of flow reversal in all subjects with mean peak velocities of -21 cm s-1 . The observation of only mildly flattened parabolic velocity distributions within the IVC indicated mostly laminar flow. Breath holding reduced blood flow velocities and rates by more than 40% on average, while Valsalva maneuvers completely abolished venous return. In conclusion, IVC blood flow is dominated by the acquired respiratory behavior of individual subjects and its pressure-induced alterations relative to cardiac pulsation. The responses to breath holding and Valsalva maneuver are in full agreement with previous invasive observations of reduced or even ceased flow, respectively.


Asunto(s)
Imagen por Resonancia Magnética , Flujo Sanguíneo Regional/fisiología , Respiración , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/fisiología , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Contencion de la Respiración , Femenino , Humanos , Masculino
17.
Neuroimage ; 200: 159-173, 2019 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-31226496

RESUMEN

The sensitivity to subject motion is one of the major challenges in functional MRI (fMRI) studies in which a precise alignment of images from different time points is required to allow reliable quantification of brain activation throughout the scan. Especially the long measurement times and laborious fMRI tasks add to the amount of subject motion found in typical fMRI measurements, even when head restraints are used. In case of moving subjects, prospective motion correction can maintain the relationship between spatial image information and subject anatomy by constantly adapting the image slice positioning to follow the subject in real time. Image-based prospective motion correction is well-established in fMRI studies and typically computes the motion estimates based on a volume-to-volume image registration, resulting in low temporal resolution. This study combines fMRI using simultaneous multislice imaging with multislice-to-volume-based image registration to allow sub-TR motion detection with subsequent real-time adaption of the imaging system. Simultaneous multislice imaging is widely used in fMRI studies and, together with multislice-to-volume-based image registration algorithms, enables computing suitable motion states after only a single readout by registering the simultaneously excited slices to a reference volume acquired at the start of the measurement. The technique is evaluated in three human BOLD fMRI studies (n = 1, 5, and 1) to explore different aspects of the method. It is compared to conventional, volume-to-volume-based prospective motion correction as well as retrospective motion correction methods. Results show a strong reduction in retrospectively computed residual motion parameters of up to 50% when comparing the two prospective motion correction techniques. An analysis of temporal signal-to-noise ratio as well as brain activation results shows high consistency between the results before and after additional retrospective motion correction when using the proposed technique, indicating successful prospective motion correction. The comparison of absolute tSNR values does not show an improvement compared to using retrospective motion correction alone. However, the improved temporal resolution may provide improved tSNR in the presence of more exaggerated intra-volume motion.


Asunto(s)
Artefactos , Encéfalo/diagnóstico por imagen , Neuroimagen Funcional/normas , Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Adulto , Femenino , Movimientos de la Cabeza/fisiología , Humanos , Masculino , Persona de Mediana Edad , Respiración , Adulto Joven
18.
Magn Reson Med ; 81(1): 234-246, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30058147

RESUMEN

PURPOSE: To improve the depiction and tracking of vocal tract articulators in spiral real-time MRI (RT-MRI) of speech production by estimating and correcting for dynamic changes in off-resonance. METHODS: The proposed method computes a dynamic field map from the phase of single-TE dynamic images after a coil phase compensation where complex coil sensitivity maps are estimated from the single-TE dynamic scan itself. This method is tested using simulations and in vivo data. The depiction of air-tissue boundaries is evaluated quantitatively using a sharpness metric and visual inspection. RESULTS: Simulations demonstrate that the proposed method provides robust off-resonance correction for spiral readout durations up to 5 ms at 1.5T. In -vivo experiments during human speech production demonstrate that image sharpness is improved in a majority of data sets at air-tissue boundaries including the upper lip, hard palate, soft palate, and tongue boundaries, whereas the lower lip shows little improvement in the edge sharpness after correction. CONCLUSION: Dynamic off-resonance correction is feasible from single-TE spiral RT-MRI data, and provides a practical performance improvement in articulator sharpness when applied to speech production imaging.


Asunto(s)
Imagen por Resonancia Magnética , Boca/diagnóstico por imagen , Paladar Blando/fisiología , Faringe/fisiología , Procesamiento de Señales Asistido por Computador , Habla/fisiología , Algoritmos , Simulación por Computador , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Reproducibilidad de los Resultados , Lengua/fisiología
19.
Magn Reson Med ; 82(2): 600-613, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30919494

RESUMEN

PURPOSE: To demonstrate a tagging method compatible with RT-MRI for the study of speech production. METHODS: Tagging is applied as a brief interruption to a continuous real-time spiral acquisition. Tagging can be initiated manually by the operator, cued to the speech stimulus, or be automatically applied with a fixed frequency. We use a standard 2D 1-3-3-1 binomial SPAtial Modulation of Magnetization (SPAMM) sequence with 1 cm spacing in both in-plane directions. Tag persistence in tongue muscle is simulated and validated in vivo. The ability to capture internal tongue deformations is tested during speech production of American English diphthongs in native speakers. RESULTS: We achieved an imaging window of 650-800 ms at 1.5T, with imaging signal to noise ratio ≥ 17 and tag contrast to noise ratio ≥ 5 in human tongue, providing 36 frames/s temporal resolution and 2 mm in-plane spatial resolution with real-time interactive acquisition and view-sharing reconstruction. The proposed method was able to capture tongue motion patterns and their relative timing with adequate spatiotemporal resolution during the production of American English diphthongs and consonants. CONCLUSION: Intermittent tagging during real-time MRI of speech production is able to reveal the internal deformations of the tongue. This capability will allow new investigations of valuable spatiotemporal information on the biomechanics of the lingual subsystems during speech without reliance on binning speech utterance repetition.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Medición de la Producción del Habla/métodos , Habla/fisiología , Lengua , Adulto , Femenino , Humanos , Masculino , Movimiento/fisiología , Lengua/diagnóstico por imagen , Lengua/fisiología
20.
Magn Reson Med ; 82(3): 1000-1011, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31033051

RESUMEN

PURPOSE: To achieve dynamic water/fat separation and B0 field inhomogeneity mapping via model-based reconstructions of undersampled triple-echo multi-spoke radial FLASH acquisitions. METHODS: This work introduces an undersampled triple-echo multi-spoke radial FLASH sequence, which uses (i) complementary radial spokes per echo train for faster spatial encoding, (ii) asymmetric echoes for flexible and nonuniform echo spacing, and (iii) a golden angle increment across frames for optimal k-space coverage. Joint estimation of water, fat, B0 inhomogeneity, and coil sensitivity maps from undersampled triple-echo data poses a nonlinear and non-convex inverse problem which is solved by a model-based reconstruction with suitable regularization. The developed methods are validated using phantom experiments with different degrees of undersampling. Real-time MRI studies of the knee, liver, and heart are conducted without prospective gating or retrospective data sorting at temporal resolutions of 70, 158, and 40 ms, respectively. RESULTS: Up to 18-fold undersampling is achieved in this work. Even in the presence of rapid physiological motion, large B0 field inhomogeneities, and phase wrapping, the model-based reconstruction yields reliably separated water/fat maps in conjunction with spatially smooth inhomogeneity maps. CONCLUSIONS: The combination of a triple-echo acquisition and joint reconstruction technique provides a practical solution to time-resolved and motion robust water/fat separation at high spatial and temporal resolution.


Asunto(s)
Tejido Adiposo/química , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Agua/química , Tejido Adiposo/diagnóstico por imagen , Corazón/diagnóstico por imagen , Humanos , Rodilla/diagnóstico por imagen , Hígado/diagnóstico por imagen , Fantasmas de Imagen