Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur Radiol ; 27(3): 1004-1011, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27300194

RESUMEN

OBJECTIVES: To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. MATERIALS AND METHODS: Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. RESULTS: The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. CONCLUSION: Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. KEY POINTS: • Sparse CE-MRA enables fast vascular imaging with full brain coverage. • Volumes with sub-millimetre resolution can be acquired within 10 seconds. • Reader's ratings are good to intermediate and dependent on contrast bolus timing. • The method provides an excellent overview and allows screening for vascular pathologies.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Enfermedades Arteriales Intracraneales/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Enfermedades Arteriales Intracraneales/patología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Adulto Joven
2.
Magn Reson Med ; 74(6): 1652-60, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25522299

RESUMEN

PURPOSE: To integrate, optimize, and evaluate a three-dimensional (3D) contrast-enhanced sparse MRA technique with iterative reconstruction on a standard clinical MR system. METHODS: Data were acquired using a highly undersampled Cartesian spiral phyllotaxis sampling pattern and reconstructed directly on the MR system with an iterative SENSE technique. Undersampling, regularization, and number of iterations of the reconstruction were optimized and validated based on phantom experiments and patient data. Sparse MRA of the whole head (field of view: 265 × 232 × 179 mm(3) ) was investigated in 10 patient examinations. RESULTS: High-quality images with 30-fold undersampling, resulting in 0.7 mm isotropic resolution within 10 s acquisition, were obtained. After optimization of the regularization factor and of the number of iterations of the reconstruction, it was possible to reconstruct images with excellent quality within six minutes per 3D volume. Initial results of sparse contrast-enhanced MRA (CEMRA) in 10 patients demonstrated high-quality whole-head first-pass MRA for both the arterial and venous contrast phases. CONCLUSION: While sparse MRI techniques have not yet reached clinical routine, this study demonstrates the technical feasibility of high-quality sparse CEMRA of the whole head in a clinical setting. Sparse CEMRA has the potential to become a viable alternative where conventional CEMRA is too slow or does not provide sufficient spatial resolution.


Asunto(s)
Arterias Cerebrales/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Algoritmos , Humanos , Angiografía por Resonancia Magnética/instrumentación , Meglumina , Compuestos Organometálicos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad , Integración de Sistemas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda