Resultados 1 - 20 de 218
Filtrar
1.
J Appl Clin Med Phys ; : e14409, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38923699

RESUMEN

BACKGROUND: To investigate the effect of the Increment of gantry angle (Inc) parameter setting of the Monaco Treatment planning system (Monaco TPS) on the dosimetry and quality parameters of the volumetric modulated arc therapy (VMAT) program for rectal cancer. METHODS: A retrospective analysis was conducted on 50 patients with rectal cancer who underwent intensity modulated radiation therapy using the Monaco TPS system from 2020 to 2021. Under the same optimization function configuration and other parameter settings, the Inc parameters in the VMAT radiotherapy plan were set to 10°, 20°, 30°, and 40°. The dose-volume histogram (DVH) was used to evaluate the dose distribution of the target area and the radiation dose of the organs at risk (OAR). The differences in the dosimetry of the planning target volume (PTV) and OAR, as well as the gamma pass rate (GPR) were compared. RESULTS: In terms of target dose, D98, Dmin, HI, and conformity index (CI) of Inc10 group was significantly lower than those of Inc20, 30, and 40 groups (P < 0.05), and D2 of Inc10 group was significantly higher than that of Inc20 group (P = 0.009). We also found CI of Inc20 and 30 were significantly better than that of Inc40 (both P < 0.05). In terms of OAR dose, the study found that the Dmean, Dmin, V50%, V45%, and V40% for the bladder of the Inc10 group were lower than those of the other groups (all P < 0.05), the Dmean for femoral head of the Inc20 group was lower than that of the Inc30 group (P < 0.05), and Inc20 showed a better protective effect on the femoral head. The MUs tend to decrease as the Inc parameter setting is increased. The monitor unit (MU) in Inc10 group were significantly higher than those in Inc20, Inc30, and Inc40 groups, and the MU of Inc20 group was significantly higher than that of Inc40 group (both P < 0.05). We found that for the 3%/3 mm and 2%/2 mm standards, the GPRs of each plan were > 90%, which met clinical requirements. CONCLUSIONS: Different settings of Inc parameters have varying degrees of impact on target dose, OAR dose, and machine MU. It is important for doctors to choose different Inc parameters according to different clinical needs.

2.
J Appl Clin Med Phys ; 24(2): e13832, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36444164

RESUMEN

Kilovoltage radiotherapy dose calculations are generally performed with manual point dose calculations based on water dosimetry. Tissue heterogeneities, irregular surfaces, and introduction of lead cutouts for treatment are either not taken into account or crudely approximated in manual calculations. Full Monte Carlo (MC) simulations can account for these limitations but require a validated treatment unit model, accurately segmented patient tissues and a treatment planning interface (TPI) to facilitate the simulation setup and result analysis. EGSnrc was used in this work to create a model of Xstrahl kilovoltage unit extending the range of energies, applicators, and validation parameters previously published. The novel functionality of the Python-based framework developed in this work allowed beam modification using custom lead cutouts and shields, commonly present in kilovoltage treatments, as well as absolute dose normalization using the output of the unit. 3D user-friendly planning interface of the developed framework facilitated non-co-planar beam setups for CT phantom MC simulations in DOSXYZnrc. The MC models of 49 clinical beams showed good agreement with measured and reference data, to within 2% for percentage depth dose curves, 4% for beam profiles at various depths, 2% for backscatter factors, 0.5 mm of absorber material for half-value layers, and 3% for output factors. End-to-end testing of the framework using custom lead cutouts resulted in good agreement to within 3% of absolute dose distribution between simulations and EBT3 GafChromic film measurements. Gamma analysis demonstrated poor agreement at the field edges which was attributed to the limitations of simulating smooth cutout shapes. Dose simulated in a heterogeneous phantom agreed to within 7% with measured values converted using the ratio of mass energy absorption coefficients of appropriate tissues and air.


Asunto(s)
Radiometría , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiometría/métodos , Simulación por Computador , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Método de Montecarlo , Dosificación Radioterapéutica
3.
J Appl Clin Med Phys ; 24(8): e14003, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37170654

RESUMEN

BACKGROUND: The currently available treatment planning systems (TPSs) are neither designed nor intended for accurate dose calculations in nontarget regions. The aim of this work is to quantify the accuracy and reliability of nontarget doses calculated by a commercially available TPS. METHODS: Nontarget doses calculated by the collapsed cone (CC) (v5.2) algorithm implemented in the RayStation (v6) TPS were compared to measured values. Different scenarios were investigated, from simple static fields to intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans. Deviations and confidence limits (CLs) were calculated between results of calculations and measurements-applying both local (δ) and global (Δ) normalization-for various points of interest (POIs). Results were based on a single-institution experience for one clinical test case (prostate) and evaluated against internationally accepted criteria. RESULTS: Overall, the TPS underestimated the nontarget dose by an average of -17.7% ± 25.3% for IMRT. Quantitatively similar results were obtained for VMAT (-17.6% ± 21.2%). POIs receiving < 5% of the prescription dose were significantly underestimated by the TPS (p-value < 0.05 for both IMRT and VMAT). Dose calculation accuracy was also determined by the contribution of secondary radiation, with measured doses for out-of-field POIs being significantly different from calculated values (p-value < 0.01 for both IMRT and VMAT). Although the CLδ in nontarget regions failed the proposed tolerance criteria (40%) for both IMRT (68.8%) and VMAT (52.6%), the CLΔ was within the tolerance limit (4%) for both treatment techniques (1.9% for IMRT and 1.3% for VMAT). No action levels (7%) were exceeded. CONCLUSIONS: Based on the currently available benchmarks our TPS is considered acceptable for clinical use, although the dose in some POIs was poorly predicted by the CC algorithm. Some areas were pointed out where TPSs and linear accelerator control systems can be improved.


Asunto(s)
Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
4.
J Appl Clin Med Phys ; 24(2): e13831, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36593751

RESUMEN

PURPOSE: To assess treatment planning system (TPS) accuracy in estimating the stopping-power ratio (SPR) of immobilization devices commonly used in proton therapy and to evaluate the dosimetric effect of SPR estimation error for a set of clinical treatment plans. METHODS: Computed tomography scans of selected clinical immobilization devices were acquired. Then, the water-equivalent thickness (WET) and SPR values of these devices based on the scans were estimated in a commercial TPS. The reference SPR of each device was measured using a multilayer ion chamber (MLIC), and the differences between measured and TPS-estimated SPRs were calculated. These findings were utilized to calculate corrected dose distributions of 15 clinical proton plans for three treatment sites: extremity, abdomen, and head-and-neck. The original and corrected dose distributions were compared using a set of target and organs-at-risk (OARs) dose-volume histogram (DVH) parameters. RESULTS: On average, the TPS-estimated SPR was 19.5% lower (range, -35.1% to 0.2%) than the MLIC-measured SPR. Due to the relatively low density of most immobilization devices used, the WET error was typically <1 mm, but up to 2.2 mm in certain devices. Overriding the SPR of the immobilization devices to the measured values did not result in significant changes in the DVH metrics of targets and most OARs. However, some critical OARs showed noticeable changes of up to 6.7% in maximum dose. CONCLUSIONS: The TPS tends to underestimate the SPR of selected proton immobilization devices by an average of about 20%, but this does not induce major WET errors because of the low density of the devices. The dosimetric effect of this SPR error was negligible for most treatment sites, although the maximum dose of a few OARs exhibited noticeable variations.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Radiometría
5.
J Appl Clin Med Phys ; 24(5): e13902, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36637797

RESUMEN

The aim of this work is to describe the implementation and commissioning of a plaque brachytherapy program using Eye Physics eye plaques and Plaque Simulator treatment planning system based on the experience of one institution with an established COMS-based plaque program. Although commissioning recommendations are available in official task groups publications such as TG-129 and TG-221, we found that there was a lack of published experiences with the specific details of such a transition and the practical application of the commissioning guidelines. The specific issues addressed in this paper include discussing the lack of FDA approval of the Eye Physics plaques and Plaque Simulator treatment planning system, the commissioning of the plaques and treatment planning system including considerations of the heterogeneity corrected calculations, and the implementation of a second check using an FDA-approved treatment planning system. We have also discussed the use of rental plaques, the analysis of plans using dose histograms, and the development of a quality management program. By sharing our experiences with the commissioning of this program this document will assist other institutions with the same task and act as a supplement to the recommendations in the recently published TG-221.


Asunto(s)
Braquiterapia , Neoplasias del Ojo , Melanoma , Humanos , Dosificación Radioterapéutica , Radioisótopos de Yodo/uso terapéutico , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador
6.
J Xray Sci Technol ; 31(5): 1013-1033, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37393487

RESUMEN

BACKGROUND: Accurate and fast dose calculation is crucial in modern radiation therapy. Four dose calculation algorithms (AAA, AXB, CCC, and MC) are available in Varian Eclipse and RaySearch Laboratories RayStation Treatment Planning Systems (TPSs). OBJECTIVES: This study aims to evaluate and compare dosimetric accuracy of the four dose calculation algorithms applying to homogeneous and heterogeneous media, VMAT plans (based on AAPM TG-119 test cases), and the surface and buildup regions. METHODS: The four algorithms are assessed in homogeneous (IAEA-TECDOCE 1540) and heterogeneous (IAEA-TECDOC 1583) media. Dosimetric evaluation accuracy for VMAT plans is then analyzed, along with the evaluation of the accuracy of algorithms applying to the surface and buildup regions. RESULTS: Tests conducted in homogeneous media revealed that all algorithms exhibit dose deviations within 5% for various conditions, with pass rates exceeding 95% based on recommended tolerances. Additionally, the tests conducted in heterogeneous media demonstrate high pass rates for all algorithms, with a 100% pass rate observed for 6 MV and mostly 100% pass rate for 15 MV, except for CCC, which achieves a pass rate of 94%. The results of gamma index pass rate (GIPR) for dose calculation algorithms in IMRT fields show that GIPR (3% /3 mm) for all four algorithms in all evaluated tests based on TG119, are greater than 97%. The results of the algorithm testing for the accuracy of superficial dose reveal variations in dose differences, ranging from -11.9% to 7.03% for 15 MV and -9.5% to 3.3% for 6 MV, respectively. It is noteworthy that the AXB and MC algorithms demonstrate relatively lower discrepancies compared to the other algorithms. CONCLUSIONS: This study shows that generally, two dose calculation algorithms (AXB and MC) that calculate dose in medium have better accuracy than other two dose calculation algorithms (CCC and AAA) that calculate dose to water.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Programas Informáticos , Radiometría/métodos , Radioterapia de Intensidad Modulada/métodos , Método de Montecarlo
7.
Rep Pract Oncol Radiother ; 28(2): 241-254, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37456703

RESUMEN

Background: Beam matching is widely used to ensure that linear accelerators used in radiotherapy have equal dosimetry characteristics. Small-field output factors (OF) were measured using different detectors infour beam-matched linear accelerators and the measured OFs were compared with existing treatment planning system (TPS) Monte Carlo algorithm calculated OFs. Materials and methods: Three Elekta Versa HDTM and one Elekta InfinityTMlinear accelerators with photon energies of 6 MV flattening filter (FF), 10 MVFF, 6 MV flattening filter free (FFF) and 10 MVFFF were used in this study. All the Linac'swere beam-matched, Dosimetry beam data were ± 1% compare with Reference Linac. Ten different type of detectors (four ionizationchambers and six diode detectors) were used for small-field OF measurements. The OFs were measured for field sizes of 1 × 1 to 10 × 10 cm2, and normalized to 10 × 10 cm2 field size. The uncorrected and corrected OFs were calculated from these measurements. The corrected OF was compare with existing treatment planning system (TPS) Monte Carlo algorithm calculated OFs. Results: The small-field corrected and Uncorrected OF variations among the linear accelerators was within 1% for all energies and detectors. An increase in field size led to a reduction in the difference between OFs among the detectors, which was the case for all energies. The RSD values decreased with increasing field size. The TRS 483 provided Detector-specificoutput-correction factor (OCF) reduced uncertainty in small-field measurements. Conclusion: It is necessary to implement the OF-correction of small fields in a TPS. Special care must be taken to incorporate the corrected small-field OF in a TPS.

8.
J Appl Clin Med Phys ; 23(8): e13732, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35856911

RESUMEN

BACKGROUND: RaySearch (AB, Stockholm) has released a module for CyberKnife (CK) planning within its RayStation (RS) treatment planning system (TPS). PURPOSE: To create and validate beam models of fixed, Iris, and multileaf collimators (MLC) of the CK M6 for Monte Carlo (MC) and collapsed cone (CC) algorithms in the RS TPS. METHODS: Measurements needed for the creation of the beam models were performed in a water tank with a stereotactic PTW 60018 diode. Both CC and MC models were optimized in RS by minimizing the differences between the measured and computed profiles and percentage depth doses. The models were then validated by comparing dose from the plans created in RS with both single and multiple beams in different phantom conditions with the corresponding measured dose. Irregular field shapes and off-axis beams were also tested for the MLC. Validation measurements were performed using an A1SL ionization chamber, EBT3 Gafchromic films, and a PTW 1000 SRS detector. Finally, patient-specific QAs with gamma criteria of 3%/1 mm were performed for each model. RESULTS: The models were created in a straightforward manner with efficient tools available in RS. The differences between computed and measured doses were within ±1% for most of the configurations tested and reached a maximum of 3.2% for measurements at a depth of 19.5-cm. With respect to all collimators and algorithms, the maximum averaged dose difference was 0.8% when considering absolute dose measurements on the central axis. The patient-specific QAs led to a mean result of 98% of points fulfilling gamma criteria. CONCLUSIONS: We created both CC and MC models for fixed, Iris, and MLC collimators in RS. The dose differences for all collimators and algorithms were within ±1%, except for depths larger than 9 cm. This allowed us to validate both models for clinical use.


Asunto(s)
Algoritmos , Planificación de la Radioterapia Asistida por Computador , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Rep Pract Oncol Radiother ; 27(5): 863-874, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523800

RESUMEN

Background: It is important to evaluate the dose calculated by treatment planning systems (TPSs) and dose distribution in tumor and organs at risk (OARs). The aim of this study is to compare dose calculated by the PRIMO Monte Carlo code and Eclipse TPS in radiotherapy of brain cancer patients. Materials and methods: PRIMO simulation code was used to simulate a Varian Clinac 600C linac. The simulations were validated for the linac by comparison of the simulation and measured results. In the case of brain cancer patients, the dosimetric parameters obtained by the PRIMO code were compared with those calculated by Eclipse TPS. Gamma function analysis with 3%, 3 mm criteria was utilized to compare the dose distributions. The evaluations were based on the dosimetric parameters for the planning target volume (PTV) and OAR including D min, D mean, and D max, homogeneity index (HI), and conformity index (CI). Results: The gamma function analysis showed a 98% agreement between the results obtained by the PRIMO code and measurement for the percent depth dose (PDD) and dose profiles. The corresponding value in comparing the dosimetric parameters from PRIMO code and Eclipse TPS for the brain patients was 94%, on average. The results of the PRIMO simulation were in good agreement with the measured data and Eclipse TPS calculations. Conclusions: Based on the results of this study, the PRIMO code can be utilized to simulate a medical linac with good accuracy and to evaluate the accuracy of treatment plans for patients with brain cancer.

10.
Acta Oncol ; 60(11): 1386-1391, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34184605

RESUMEN

BACKGROUND: Hypoxia dose painting is a radiotherapy technique to increase the dose to hypoxic regions of the tumour. Still, the clinical effect relies on the reproducibility of the hypoxic region shown in the medical image. 18F-EF5 is a hypoxia tracer for positron emission tomography (PET), and this study investigated the repeatability of 18F-EF5-based dose painting by numbers (DPBN) in head and neck cancer (HNC). MATERIALS AND METHODS: Eight HNC patients undergoing two 18F-EF5-PET/CT sessions (A and B) before radiotherapy were included. A linear conversion of PET signal intensity to radiotherapy dose prescription was employed and DPBN treatment plans were created using the image basis acquired at each PET/CT session. Also, plan A was recalculated on the image basis for session B. Voxel-by-voxel Pearson's correlation and quality factor were calculated to assess the DPBN plan quality and repeatability. RESULTS: The mean (SD) correlation coefficient between DPBN prescription and plan was 0.92 (0.02) and 0.93 (0.02) for sessions A and B, respectively, with corresponding quality factors of 0.02 (0.002) and 0.02 (0.003), respectively. The mean correlation between dose prescriptions at day A and B was 0.72 (0.13), and 0.77 (0.12) for the corresponding plans. A mean correlation of 0.80 (0.08) was found between plan A, recalculated on image basis B, and plan B. CONCLUSION: Hypoxia DPBN planning based on 18F-EF5-PET/CT showed high repeatability. This illustrates that 18F-EF5-PET provides a robust target for dose painting.


Asunto(s)
Neoplasias de Cabeza y Cuello , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Hipoxia , Tomografía de Emisión de Positrones , Radiofármacos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados
11.
J Appl Clin Med Phys ; 22(3): 94-106, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33547766

RESUMEN

PURPOSE: First, this experimental study aims at comparing out-of-field doses delivered by three radiotherapy techniques (3DCRT, VMAT (two different accelerators), and tomotherapy) for a pediatric renal treatment. Secondly, the accuracy of treatment planning systems (TPS) for out-of-field calculation is evaluated. METHODS: EBT3 films were positioned in pediatric phantoms (5 and 10 yr old). They were irradiated according to four plans: 3DCRT (Clinac 2100CS, Varian), VMAT (Clinac 2100CS and Halcyon, Varian), and tomotherapy for a same target volume. 3D dose determination was performed with an in-house Matlab tool using linear interpolation of film measurements. 1D and 3D comparisons were made between techniques. Finally, measurements were compared to the Eclipse (Varian) and Tomotherapy (Accuray) TPS calculations. RESULTS: Advanced radiotherapy techniques (VMATs and tomotherapy) deliver higher out-of-field doses compared to 3DCRT due to increased beam-on time triggered by intensity modulation. Differences increase with distance to target and reach a factor of 3 between VMAT and 3DCRT. Besides, tomotherapy delivers lower doses than VMAT: although tomotherapy beam-on time is higher than in VMAT, the additional shielding of the Hi-Art system reduces out-of-field doses. The latest generation Halcyon system proves to deliver lower peripheral doses than conventional accelerators. Regarding TPS calculation, tomotherapy proves to be suitable for out-of-field dose determination up to 30 cm from field edge whereas Eclipse (AAA and AXB) largely underestimates those doses. CONCLUSION: This study shows that the high dose conformation allowed by advanced radiotherapy is done at the cost of higher peripheral doses. In the context of treatment-related risk estimation, the consequence of this increase might be significative. Modern systems require adapted head shielding and a particular attention has to be taken regarding on-board imaging dose. Finally, TPS advanced dose calculation algorithms do not certify dose accuracy beyond field edges, and thus, those doses are not suitable for risk assessment.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Algoritmos , Niño , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica
12.
J Appl Clin Med Phys ; 21(9): 266-271, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32790244

RESUMEN

PURPOSE: The purpose of this study was to present the proton beam characteristics of the first clinical single-room ProBeam Compact™ proton therapy system (SRPT) and comparison against multi-room ProBeam™ system (MRPT). MATERIALS AND METHODS: A newly designed SRPT with proton beam energies ranging from 70 to 220 MeV was commissioned in late 2019. Integrated depth doses (IDDs) were scanned using 81.6 mm diameter Bragg peak chambers and normalized by outputs at 15 mm WET and 1.1 RBE offset, following the methodology of TRS 398. The in-air beam spot profiles were acquired by a planar scintillation device, respectively, at ISO, upper and down streams, fitted with single Gaussian distribution for beam modeling in Eclipse v15.6. The field size effect was adjusted for the best overall accuracy of clinically relevant field QAs. The halo effects at near surface were quantified by a pinpoint ionization chamber. Its major dosimetric characteristics were compared against MRPT comparable beam dataset. RESULTS: Contrast to MRPT, an increased proton straggling in the Bragg peak region was found with widened beam distal falloffs and elevated proximal transmission dose values. Integrated depth doses showed 0.105-0.221 MeV (energy sigma) or 0.30-0.94 mm broader Bragg peak widths (Rb80 -Ra80 ) for 130 MeV or higher energy beams and up to 0.48-0.79 mm extended distal falloffs (Rb20 -Rb80 ). Minor differences were identified in beam spot sizes, spot divergences, proton particles/MU, and field size output effects. High passing scores are reported for independent end-to-end dosimetry checks by IROC and for initial 108 field-specific QAs at 3%/3 mm Gamma index with fields regardless with or without range shifters. CONCLUSIONS: The author highlighted the dosimetry differences in IDDs mainly caused by the shortened beam transport system of SRPT, for which new acceptance criteria were adapted. This report offers a unique reference for future commissioning, beam modeling, planning, and analysis of QA and clinical studies.


Asunto(s)
Terapia de Protones , Protones , Humanos , Distribución Normal , Radiometría , Dosificación Radioterapéutica
13.
J Appl Clin Med Phys ; 21(2): 82-88, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31961036

RESUMEN

PURPOSE: Treatment planning system (TPS) dose calculation is sensitive to multileaf collimator (MLC) modeling, especially when treating with intensity-modulated radiation therapy (IMRT) or VMAT. This study investigates the dosimetric impact of the MLC leaf-tip model in a commercial TPS (RayStation v.6.1). The detectability of modeling errors was assessed through both measurements with an anthropomorphic head-and-neck phantom and patient-specific IMRT QA using a 3D diode array. METHODS AND MATERIALS: An Agility MLC (Elekta Inc.) was commissioned in RayStation. Nine IMRT and VMAT plans were optimized to treat the head-and-neck phantom from the Imaging and Radiation Oncology Core Houston branch (IROC-H). Dose distributions for each plan were re-calculated on 27 beam models, varying leaf-tip width (2.0, 4.5, and 6.5 mm) and leaf-tip offset (-2.0 to +2.0 mm) values. Doses were compared to phantom TLD measurements. Patient-specific IMRT QA was performed, and receiver-operating characteristic (ROC) analysis was performed to determine the detectability of modeling errors. RESULTS: Dose calculations were very sensitive to leaf-tip offset values. Offsets of ±1.0 mm resulted in dose differences up to 10% and 15% in the PTV and spinal cord TLDs respectively. Offsets of ±2.0 mm caused dose deviations up to 50% in the spinal cord TLD. Patient-specific IMRT QA could not reliably detect these deviations, with an ROC area under the curve (AUC) value of 0.537 for a ±1.0 mm change in leaf-tip offset, corresponding to >7% dose deviation. Leaf-tip width had a modest dosimetric impact with <2% and 5.6% differences in the PTV and spinal cord TLDs respectively. CONCLUSIONS: Small changes in the MLC leaf-tip offset in this TPS model can cause large changes in the calculated dose for IMRT and VMAT plans that are difficult to identify through either dose curves or standard patient-specific IMRT QA. These results may, in part, explain the reported high failure rate of IROC-H phantom tests.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Antropometría , Área Bajo la Curva , Diseño de Equipo , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Control de Calidad , Curva ROC , Oncología por Radiación/normas , Radiometría , Dosificación Radioterapéutica , Reproducibilidad de los Resultados
14.
J Appl Clin Med Phys ; 21(7): 135-143, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32391645

RESUMEN

This study aimed to investigate the feasibility of independent calculation-based verification of volumetric-modulated arc therapy (VMAT)-stereotactic body radiotherapy (SBRT) for patients with lung cancer using a secondary treatment planning system (sTPS). In all, 50 patients with lung cancer who underwent VMAT-SBRT between April 2018 and May 2019 were included in this study. VMAT-SBRT plans were devised using the Collapsed-Cone Convolution in RayStation (primary TPS: pTPS). DICOM files were transferred to Eclipse software (sTPS), which utilized the Eclipse software, and the dose distribution was then recalculated using Acuros XB. For the verification of dose distribution in homogeneous phantoms, the differences among pTPS, sTPS, and measurements were evaluated using passing rates of a dose difference of 5% (DD5%) and gamma index of 3%/2 mm (γ3%/2 mm). The ArcCHECK cylindrical diode array was used for measurements. For independent verification of dose-volume parameters per the patient's geometry, dose-volume indices for the planning target volume (PTV) including D95% and the isocenter dose were evaluated. The mean differences (± standard deviations) between the pTPS and sTPS were then calculated. The gamma passing rates of DD5% and γ3%/2 mm criteria were 99.2 ± 2.4% and 98.6 ± 3.2% for pTPS vs. sTPS, 92.9 ± 4.0% and 94.1 ± 3.3% for pTPS vs. measurement, and 93.0 ± 4.4% and 94.3 ± 4.1% for sTPS vs. measurement, respectively. The differences between pTPS and sTPS for the PTVs of D95% and the isocenter dose were -3.1 ± 2.0% and -2.3 ± 1.8%, respectively. Our investigation of VMAT-SBRT plans for lung cancer revealed that independent calculation-based verification is a time-efficient method for patient-specific quality assurance.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
15.
Artículo en Japonés | MEDLINE | ID: mdl-32307368

RESUMEN

Multi-leaf collimator (MLC) parameters, which are registered with radiation treatment planning systems, are very important for intensity modulated radiation therapy (IMRT). In this study, we investigated MLC parameters of respective institutions for efficient commissioning of IMRT. Data of linac models, MLC types, nominal energy, irradiation technique, calculation algorithm, dosimetric leaf gap (DLG) values, and MLC transmission values were collected from each institution in which Varian linac and Eclipse were owned, and analyzed. The numbers of responses from institutions to questionnaire were 15, and the total number of linac was 22. In most institutions, volumetric modulated arc therapy (VMAT) technique was used, and the most used nominal energy was 10 MV. The higher nominal energy was, the higher values of MLC parameters (DLG and MLC transmission) were. In addition, values of MLC parameters of flattening filter free (FFF) beams were smaller than those of flattening filter (FF) beams, even when nominal energy was same. Values of DLG of VMAT tended to be greater than those of multi-field IMRT. These results are expected to be useful for institutions, in which IMRT is implemented.


Asunto(s)
Radioterapia de Intensidad Modulada , Aceleradores de Partículas , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
16.
J Appl Clin Med Phys ; 20(10): 33-42, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31471950

RESUMEN

The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (PDD) curves, beam profiles, output factors, leaf transmission factors and dosimetric leaf gaps (DLGs) were acquired in accordance with the AAPM task group reports No. 45 and No. 106 and the vendor-supplied documents. The measured data were imported into Eclipse TPS to build a VersaHD beam model. The model was validated by creating treatment plans spanning over the full-spectrum of treatment sites and techniques used in our clinic. The quality assurance measurements were performed using MatriXX, ionization chamber, and radiochromic film. The DLG values were iteratively adjusted to optimize the agreement between planned and measured doses. Mobius, an independent LINAC logfile-based quality assurance tool, was also commissioned both for routine intensity-modulated radiation therapy (IMRT) QA and as a secondary check for the Eclipse VersaHD model. The Eclipse-generated VersaHD model was in excellent agreement with the measured PDD curves and beam profiles. The measured leaf transmission factors were less than 0.5% for all energies. The model validation study yielded absolute point dose agreement between ionization chamber measurements and Eclipse within ±4% for all cases. The comparison between Mobius and Eclipse, and between Mobius and ionization chamber measurements lead to absolute point dose agreement within ±5%. The corresponding 3D dose distributions evaluated with 3%global/2mm gamma criteria resulted in larger than 90% passing rates for all plans. The Eclipse TPS can model VersaHD LINACs with clinically acceptable accuracy. The model validation study and comparisons with Mobius demonstrated that the modeling of VersaHD in Eclipse necessitates further improvement to provide dosimetric accuracy on par with Varian LINACs.


Asunto(s)
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Fotones , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
17.
J Appl Clin Med Phys ; 20(8): 114-121, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31343831

RESUMEN

We sought to validate new couch modeling optimization for tomotherapy planning and delivery. We constructed simplified virtual structures just above a default setting couch through a planning support system (MIM Maestro, version 8.2, MIM Software Inc, Cleveland, OH, USA). Based on ionization chamber measurements, we performed interactive optimization and determined the most appropriate physical density of these virtual structures in a treatment planning system (TPS). To validate this couch optimization, Gamma analysis and these statistical analyses between a three-dimensional diode array QA system (ArcCHECK, Sun Nuclear, Melbourne, FL, USA) results and calculations from ionization chamber measurements were performed at 3%/2 mm criteria with a threshold of 10% in clinical QA plans. Using a virtual model consisting of a center slab density of 4.2 g/cm3 and both side slabs density of 1.9 g/cm3 , we demonstrated close agreement between measured dose and the TPS calculated dose. Agreement was within 1% for all gantry angles at the isocenter and within 2% in off-axis plans. In validation of the couch modeling in a clinical QA plan, the average gamma passing rate improved approximately 0.6%-5.1%. It was statistically significant (P < 0.05) for all treatment sites. We successfully generated an accurate couch model for a TomoTherapy TPS by interactively optimizing the physical density of the couch using a planning support system. This modeling proved to be an efficient way of correcting the dosimetric effects of the treatment couch in tomotherapy planning and delivery.


Asunto(s)
Modelos Teóricos , Neoplasias/radioterapia , Posicionamiento del Paciente , Garantía de la Calidad de Atención de Salud/normas , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/instrumentación , Algoritmos , Fibra de Carbono/química , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
18.
J Appl Clin Med Phys ; 20(6): 23-30, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31017371

RESUMEN

Iodine-125 seed brachytherapy has great potential in the treatment of malignant tumors. However, the success of this treatment is highly dependent on the ability to accurately position the coplanar template. The aim of this study was to develop an auto-positioning system for the template with a design focus on efficiency and accuracy. In this study, an auto-positioning system was presented, which was composed of a treatment planning system (TPS) and a robot-assisted system. The TPS was developed as a control system for the robot-assisted system. Then, the robot-assisted system was driven by the output of the TPS to position the template. Contrast experiments for error validation were carried out in a computed tomography environment to compare with the traditional positioning method (TPM). Animal experiments on Sprague-Dawley rats were also carried out to evaluate the auto-positioning system. The error validation experiments and animal experiments with this auto-positioning system were successfully carried out with improved efficiency and accuracy. The error validation experiments achieved a positioning error of 1.04 ± 0.19 mm and a positioning time of 23.15 ± 2.52 min, demonstrating a great improvement compared with the TPM (2.55 ± 0.21 mm and 40.35 ± 2.99 min, respectively). The animal experiments demonstrated that the mean deviation of the seed position was 0.75 mm. The dose-volume histogram of the preoperative planning showed the same as the postoperative dosimetry validation. A novel auto-positioning system driven by preoperative planning was established, which exhibited higher efficiency and accuracy compared with the TPM.


Asunto(s)
Algoritmos , Braquiterapia/métodos , Radioisótopos de Yodo/administración & dosificación , Cuidados Preoperatorios , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Animales , Radioisótopos de Yodo/farmacocinética , Masculino , Método de Montecarlo , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Ratas , Ratas Sprague-Dawley , Programas Informáticos , Distribución Tisular
19.
J Appl Clin Med Phys ; 20(7): 28-38, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31254376

RESUMEN

PURPOSE: The magnetic field can cause a nonnegligible dosimetric effect in an MR-Linac system. This effect should be accurately accounted for by the beam models in treatment planning systems (TPS). The purpose of the study was to verify the beam model and the entire treatment planning and delivery process for a 1.5 T MR-Linac based on comprehensive dosimetric measurements and end-to-end tests. MATERIAL AND METHODS: Dosimetry measurements and end-to-end tests were performed on a preclinical MR-Linac (Elekta AB) using a multitude of detectors and were compared to the corresponding beam model calculations from the TPS for the MR-Linac. Measurement devices included ion chambers (IC), diamond detector, radiochromic film, and MR-compatible ion chamber array and diode array. The dose in inhomogeneous phantom was also verified. The end-to-end tests include the generation, delivery, and comparison of 3D and IMRT plan with measurement. RESULTS: For the depth dose measurements with Farmer IC, micro IC and diamond detector, the absolute difference between most measurement points and beam model calculation beyond the buildup region were <1%, at most 2% for a few measurement points. For the beam profile measurements, the absolute differences were no more than 1% outside the penumbra region and no more than 2.5% inside the penumbra region. Results of end-to-end tests demonstrated that three 3D static plans with single 5 × 10 cm2 fields (at gantry angle 0°, 90° and 270°) and two IMRT plans successfully passed gamma analysis with clinical criteria. The dose difference in the inhomogeneous phantom between the calculation and measurement was within 1.0%. CONCLUSIONS: Both relative and absolute dosimetry measurements agreed well with the TPS calculation, indicating that the beam model for MR-Linac properly accounts for the magnetic field effect. The end-to-end tests verified the entire treatment planning process.


Asunto(s)
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Radiometría/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
20.
Artículo en Japonés | MEDLINE | ID: mdl-31434844

RESUMEN

Commissioning of a linear accelerator (Linac) and treatment planning systems (RTPs) for clinical use is complex and time-consuming, typically 3-4 months in total. However, based on clinical needs and economics, hospitals desire early clinical starts for patients, and various studies have been conducted for shortening the preparation period. One of the methods to shorten the period is using golden beam data (GBD). The purpose of this study was to shorten the commissioning period without reducing accuracy and to simplify commissioning works while improving safety. We conducted commissioning of the RTPs before installing the Linac using GBD, and carried out verification immediately after the acceptance test. We used TrueBeam STx (Varian Medical Systems) and Eclipse (ver. 13.7, Varian Medical Systems) for RTPs and anisotropic analysis algorithm (AAA) and AcurosXB (AXB) for calculation algorithms. The difference between GBD and the measured beam data was 0.0 ± 0.2% [percentage depth dose (PDDs) ] and -0.1 ± 0.2% (Profiles) with X-ray, and -1.2 ± 1.3% (PDDs) with electrons. The difference between the calculated dose and the measured dose was 0.1 ± 0.3% (AAA) and 0.0 ± 0.3% (AXB) under homogeneous conditions, and 0.7 ± 1.4% (AAA) and 0.6 ± 1.1% (AXB) under heterogeneous conditions. We took 43 days from the end of the acceptance test to the start of clinical use. We found that the preparation period for clinical use can be shortened without reducing the accuracy, by thinning out the number of measurement items using GBD.


Asunto(s)
Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Algoritmos , Electrones , Humanos , Método de Montecarlo , Dosificación Radioterapéutica