Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Injury ; 47(8): 1676-84, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27269418

RESUMEN

BACKGROUND: We sought to compare the incidence of complications after fixation of displaced femoral neck fractures in young adults treated with fixed-angle devices versus multiple cancellous screws and a trochanteric lag screw (Pauwel screw). METHODS: We conducted a retrospective cohort study at a level I trauma centre. Sixty-two skeletally mature patients (age range, 16-60 years) with displaced femoral neck fractures were included in the study. Forty-seven were treated with a fixed-angle device (sliding hip plate with screw or helical blade) and 15 with multiple cancellous screws placed in a Pauwel configuration. The main outcome measure was postoperative complication of osteonecrosis or nonunion treated with a surgical procedure. RESULTS: Significantly fewer failures occurred in the fixed-angle group (21%) than in the screws group (60%) (p=0.008). Osteonecrosis was rare in the fixed-angle group, occurring in 2% of cases versus 33% of cases in the screws group (p=0.002). Consistent with previous studies, good to excellent reductions were associated with a failure rate of 25% and fair to poor reductions were associated with a failure rate of 55% (p=0.07). The best-case scenario of a good to excellent reduction stabilised with a fixed-angle device yielded a success rate of 85%. CONCLUSION: In young patients with displaced high-energy femoral neck fractures, fixed-angle devices resulted in fewer treatment failures than did Pauwel screws.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Complicaciones Posoperatorias/cirugía , Adolescente , Adulto , Placas Óseas , Femenino , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/fisiopatología , Fracturas no Consolidadas/diagnóstico por imagen , Fracturas no Consolidadas/prevención & control , Fracturas no Consolidadas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteonecrosis/diagnóstico por imagen , Osteonecrosis/prevención & control , Osteonecrosis/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Radiografía , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
2.
Clin Biomech (Bristol, Avon) ; 28(8): 886-91, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24050951

RESUMEN

BACKGROUND: We assessed the biomechanical performances of a trochanteric lag screw construct and a traditional inverted triangle construct in the treatment of simulated Pauwels type 3 femoral neck fractures. METHODS: An inverted triangle construct (three 7.3-mm cannulated screws placed in inverted triangle orientation) and a trochanteric lag screw construct (two 7.3-mm cannulated screws placed across the superior portion of the femoral neck and one 4.5-mm lag screw placed perpendicular to the fracture in superolateral to inferomedial orientation) were tested in nine matched pairs of non-osteoporotic human cadaveric femora. We used a previously described vertically oriented femoral neck fracture model and testing protocol that incrementally loaded the constructs along the mechanical axis of the femur to 1400 N. Specimens that survived incremental loading underwent cyclic loading. Apparent construct stiffness, force at 3mm of displacement, and survival of incremental loading were recorded. FINDINGS: The trochanteric lag screw group had a 70% increase in stiffness (261 N/mm [29 standard deviation] versus 153 N/mm [16 standard deviation]; P=0.026) and a 43% increase in force required for displacement (620 N versus 435 N; P=0.018) compared with the inverted triangle group. One trochanteric lag screw and no inverted triangle specimen survived incremental loading. INTERPRETATION: A trochanteric lag screw construct applied to vertically oriented femoral neck fractures provides marked improvement in mechanical performance compared with the inverted triangle construct.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral/fisiopatología , Fracturas del Cuello Femoral/cirugía , Cuello Femoral/fisiopatología , Cuello Femoral/cirugía , Fenómenos Biomecánicos , Cadáver , Elasticidad , Análisis de Falla de Equipo , Fémur/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Técnicas In Vitro , Fijadores Internos , Resultado del Tratamiento , Soporte de Peso
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda