Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 2.202
Filtrar
1.
Small ; : e2310406, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38312086

RESUMEN

The quest to develop graphene-like biomass-carbon for advanced biomolecule redox modulation and sensing remains a challenge. The primary obstacle is the limited ability of biomass to undergo extensive graphitization during pyrolysis resulting in the formation of amorphous carbon materials with a small carbon-double-bond-carbon domain size (Lsp2 ), density of state (LDOS), ion diffusivity (D), and electron transfer rate constant (Ks). Herein, using almond skin (AS) the morphology of biomass is demonstrated as the key to overcoming these limitations. AS consists of 1D syringyl/guaiacyl lignin nano-coils which under H2 /H2 annealing transform into pyrolytic 1D carbon nano-coils (r-gC). Spectroscopy and microscopy analyses reveal that the sheet layering structure, crystallinity, LDOS, and Lsp2 of r-gC mimic those of graphene oxide (GO). Moreover, its unique 1D morphology and profound microstructure facilitate faster charge transfer and ion diffusion than GO's planar structure, leading to better redox modulation and sensing of the neurotransmitter dopamine (DA) in physiological fluids. r-gC's DA detection limit of 3.62 nM is below the lower threshold found in humans and on par with the state-of-the-art. r-gC is also DA-selective over 14 biochemicals. This study reveals that biomasses with well-defined and compact lignin structures are best suited for developing highly electroactive graphene-like biomass carbon.

2.
Small ; 20(22): e2312238, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38319031

RESUMEN

The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2-CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM-1 cm-2), Tyr (0.126 µA µM-1 cm-2), and PA (0.0841 µA µM-1 cm-2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2-CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2-CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.


Asunto(s)
Acetaminofén , Dopamina , Técnicas Electroquímicas , Titanio , Tirosina , Dispositivos Electrónicos Vestibles , Titanio/química , Acetaminofén/análisis , Dopamina/análisis , Tirosina/química , Técnicas Electroquímicas/métodos , Humanos , Electrodos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación
3.
Chembiochem ; : e202400294, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742670

RESUMEN

This work describes the development and evaluation of a novel electrochemical aptasensor for testosterone detection. The sensor utilizes a specifically designed DNA immobilized on a screen-printed gold electrode (SPGE) modified with a conductive hydrogel and gold nanoparticles (HG/NP) composite. The aptasensor exhibited a dose-dependent response to testosterone (0.05 to 50 ng/mL) with a detection limit of 0.14 ng/mL and a good sensitivity of 0.23 µA ng-1 mL cm-2. The sensor displayed excellent selectivity towards testosterone compared to structurally similar steroid hormones. Importantly, the incorporation of HG/NP not only improved the sensor's conductivity but also acted as an antifouling layer, minimizing signal interference from non-specific biomolecule interactions in complex biological samples like human serum. The results obtained from the aptasensor showed good correlation with a standard ELISA method, demonstrating its effectiveness in real-world scenarios.

4.
Chemistry ; 30(22): e202304024, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38391394

RESUMEN

Formaldehyde is susceptible to illegal addition to foodstuffs to extend their shelf life due to its antimicrobial, preservative and bleaching properties. In this study, a self-supporting "nanosheet on nanosheet" arrays electrocatalyst with core-shell heterostructure was prepared in situ by coupling NiCo layer double hydroxide with 2D ZIF derived Co-nitrogen-doped porous carbon on carbon cloth (Co-N/C@NiCo-LDH NSAs/CC). Co-N/C nanosheet arrays act as a scaffold core with good electrical conductivity, providing more NiCo-LDH nucleation sites to avoid NiCo-LDH agglomeration, thus having fast mass/charge transfer performance. While the NiCo-LDH nanosheet arrays shell with high specific surface area provide more active sites for electrochemical reactions. As an electrocatalytic sensing electrode, Co-N/C@NiCo-LDH NSAs/CC has a wide linear range of 1 µM to 13 mM for formaldehyde detection, and the detection limit is 82 nM. Besides, the sensor has been applied to the detection of formaldehyde in food samples with satisfactory results.

5.
Anal Biochem ; 693: 115595, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38909770

RESUMEN

Monitoring pharmaceutical drugs in various mediums is crucial to mitigate adverse effects. This study presents a chemical sensor using an oval-like zinc oxide (ZnO) nanostructure for electrochemical detection of nalbuphine. The ZnO nanostructure, produced via an efficient sol-gel technique, was extensively characterized using field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), UV-visible spectrophotometry, and fourier transform infrared spectroscopy (FTIR). A slurry of the ZnO nanostructure in a binder was applied to a glassy carbon electrode (GCE). The sensor's responsiveness to nalbuphine was assessed using linear sweep voltammetry (LSV), achieving optimal performance by fine-tuning the pH. The sensor demonstrated a proportional response to nalbuphine concentrations up to 150.0 nM with a good regression coefficient (R2) and a detection limit of 6.20 nM (S/N ratio of 3). Selectivity was validated against various interfering substances, and efficacy was confirmed through real sample analysis, highlighting the sensor's successful application for nalbuphine detection.

6.
Anal Biochem ; 690: 115509, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38508332

RESUMEN

DNA methylation aberrations have a strong correlation with cancer in early detection, diagnosis, and prognosis, which make them possible candidate biomarkers. Electrochemical biosensors offer rapid protocols for detecting DNA methylation status with minimal pretreatment of samples. However, the inevitable presence of background current in the time domain, including electrochemical noise and variations, limits the detection performance of these biosensors, especially for low concentration analytes. Here, we propose an ultrasensitive frequency-domain electrochemical analysis strategy to effectively separate the weak signals from background current. To achieve this, we employed periodic magnetic field modulation of magnetic beads (MBs) on and off the electrode surface to generate a periodic electrochemical signal for subsequent frequency-domain analysis. By capturing labeled MBs with as low as 0.5 pg of DNA, we successfully demonstrated a highly sensitive electrochemical method for determination of genome-wide DNA methylation levels. We also validated the effectiveness of this methodology using DNA samples extracted from three types of hepatocellular carcinoma (HCC) cell lines. The results revealed varying genomic methylation levels among different HCC cell lines, indicating the potential application of this approach for early-stage cancer detection in terms of DNA methylation status.

7.
Anal Biochem ; : 115597, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969155

RESUMEN

Vibrio parahaemolyticus (V. parahaemolyticus) is a major foodborne pathogen, which can cause serious foodborne illnesses like diarrhoea. Rapid on-site detection of foodborne pathogens is an ideal way to respond to foodborne illnesses. Herein, we provide an electrochemical sensor for rapid on-site detection. This sensor utilized a pH-sensitive metal-oxide material for the concurrent isothermal amplification and label-free detection of nucleic acids. Based on a pH-sensitive hydrated iridium oxide oxyhydroxide film (HIROF), the electrode transforms the hydrogen ion compound generated during nucleic acid amplification into potential, so as to achieve a real-time detection. The results can be transmitted to a smartphone via Bluetooth. Moreover, HIROF was applied in nucleic acid device detection, with a super-Nernst sensitivity of 77.6 mV/pH in the pH range of 6.0-8.5, and the sensitivity showed the best results so far. Detection of V. parahaemolyticus by this novel method showed a detection limit of 1.0×103 CFU/mL, while the time consumption was only 30 min, outperforming real-time fluorescence loop-mediated isothermal amplification (LAMP). Therefore, the characteristics of compact, portable, and fast make the sensor more widely used in on-site detection.

8.
Anal Biochem ; 692: 115571, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38796119

RESUMEN

Markers of myocardial injury, such as myoglobin (Mb), are substances swiftly released into the peripheral bloodstream upon myocardial cell injury or altered cardiac activity. During the onset of acute myocardial infarction, patients experience a significant surge in serum Mb levels. Given this, precise detection of Mb is essential, necessitating the development of innovative assays to optimize detection capabilities. This study introduces the synthesis of a three-dimensional hierarchical nanocomposite, Cubic-ZIF67@Au-rGOF-NH2, utilizing aminated reduced graphene oxide and zeolite imidazolium ester framework-67 (ZIF67) as foundational structures. Notably, this novel material, applied in a label-free electrochemical immunosensor, presents a groundbreaking approach for detecting myocardial injury markers. Experimental outcomes revealed ZIF67 and AuNPs exhibit enhanced affinity and growth on the 3D-rGOF-NH2 matrix, thus amplifying electrical conductivity while preserving the inherent electrochemical attributes of ZIF67. As a result, the Cubic-ZIF67@Au-rGOF-NH2 label-free electrochemical immunosensor exhibited a broad detection range and high sensitivity for Mb. The derived standard curve was ΔIp = 16.67552lgC+275.245 (R = 0.993) with a detection threshold of 3.47 fg/ml. Moreover, recoveries of standards spiked into samples ranged between 96.3% and 108.7%. Importantly, the devised immunosensor retained notable selectivity against non-target proteins, proving its potential clinical utility based on exemplary sample analysis performance.


Asunto(s)
Técnicas Electroquímicas , Oro , Grafito , Estructuras Metalorgánicas , Mioglobina , Mioglobina/análisis , Técnicas Electroquímicas/métodos , Grafito/química , Estructuras Metalorgánicas/química , Oro/química , Humanos , Técnicas Biosensibles/métodos , Nanocompuestos/química , Zeolitas/química , Imidazoles/química , Límite de Detección , Nanopartículas del Metal/química
9.
Chemphyschem ; 25(2): e202300633, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37921492

RESUMEN

A method for the voltammetric determination of tin using a multiwall carbon nanotubes/spherical glassy carbon (CNTs/SGC) electrode is described. The new procedure is based on the adsorptive accumulation of the Sn(II)-cupferron complex on a CNTs/SGC electrode modified with a lead film, followed by electrochemical reduction of the adsorbed species. The optimal experimental conditions include the use of 0.10 mol L-1 acetate buffer (pH 5.7), 4.0×10-4 M cupferron and 1.0×10-4 M Pb(II). The peak current is proportional to the concentration of Sn(II) over the range of 1.0×10-9 -1.0×10-7 M and the detection limit is 3.1×10-10 M for a 95 s accumulation time. The proposed method was used to determine tin in real samples and certified reference materials.

10.
Nanotechnology ; 35(17)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38334120

RESUMEN

Here, we demonstrate hydrothermally grown bismuth sulfide (Bi2S3) micro flowers decorated nickel foam (NF) for electrochemical detection of melamine in bottled milk samples. The orthorhombic phase of hydrothermally grown Bi2S3is confirmed by the detailed characterization of x-ray diffraction and its high surface area micro flowers-like morphology is investigated via field emission scanning electron microscope. Furthermore, the surface chemical oxidation state and binding energy of Bi2S3/NF micro flowers is analyzed by x-ray photoelectron spectroscopy studies. The sensor exhibits a wide linear range of detection from 10 ng l-1to 1 mg l-1and a superior sensitivity of 3.4 mA cm-2to melamine using differential pulse voltammetry technique, with a lower limit of detection (7.1 ng l-1). The as-fabricated sensor is highly selective against interfering species of p-phenylenediamine (PPDA), cyanuric acid (CA), aniline, ascorbic acid, glucose (Glu), and calcium ion (Ca2+). Real-time analysis done in milk by the standard addition method shows an excellent recovery percentage of Ì´ 98%. The sensor's electrochemical mechanism studies reveal that the high surface area bismuth sulfide micro flowers surface interacts strongly with melamine molecules through hydrogen bonding and van der Waals forces, resulting in a significant change in the sensor's electrical properties while 3D skeletal Nickel foam as a substrate provides stability, enhances its catalytic activity by providing a more number /of active sites and facilitates rapid electron transfer. The work presented here confirms Bi2S3/NF as a high-performance electrode that can be used for the detection of other biomolecules used in clinical diagnosis and biomedical research.


Asunto(s)
Bismuto , Leche , Níquel , Sulfuros , Triazinas , Animales , Níquel/química , Leche/química , Glucosa/análisis , Técnicas Electroquímicas
11.
Nanotechnology ; 35(19)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38271717

RESUMEN

Precise identification of cholesterol levels is crucial for the early diagnosis of cardiovascular risk factors. This paper presents a novel approach for cholesterol detection that circumvents the reliance on enzymatic processes. Leveraging the unique properties of advanced materials and electrochemical principles, our non-enzymatic approach demonstrates enhanced sensitivity, specificity, and limit of detection in cholesterol analysis. A non-enzymatic electrochemical biosensor for Cholesterol, employing a nanohybrid comprising Cu2O nanoparticles decorated with MoS2, is presented. The cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometry techniques were employed to investigate the electrochemical behaviour of the glassy carbon electrode modified with the Cu2O/MoS2nanohybrid. The modified electrode exhibited an excellent sensitivity of 111.74µAµM-1cm-2through the CV method and showcased a low detection limit of 2.18µM and an expansive linear range spanning 0.1-180µM when employing the DPV method. The electrode also showed good selectivity to various interfering components in 0.1 M NaOH and a satisfied stability of about 15 days at room temperature. The study demonstrates the potential for broader applications in clinical diagnostics and monitoring cardiovascular health, paving the way for a paradigm shift in cholesterol detection methodologies and offering a more efficient and cost-effective alternative to traditional enzymatic assays.


Asunto(s)
Molibdeno , Nanopartículas , Molibdeno/química , Cobre/química , Técnicas Electroquímicas/métodos , Nanopartículas/química , Electrodos , Colesterol , Límite de Detección
12.
Environ Sci Technol ; 58(6): 2881-2890, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38297912

RESUMEN

The use of microbial electrochemical sensors, with electroactive biofilms (EABs) as sensing elements, is a promising strategy to timely measure the biochemical oxygen demand (BOD) of wastewater. However, accumulation of Coulombic yield over a complete degradation cycle is time-consuming. Therefore, understanding the correlation between current output and EAB metabolism is urgently needed. Here, we recognized a tail stage (TS) on a current-time curve according to current increase rate─a period with the least electron harvesting efficiency. EAB adopted a series of metabolic compensation strategies, including slow metabolism of residual BOD, suspended growth, reduced cell activity, and consumption of carbon storage polymers, to cope with substrate deficiency in TS. The supplementary electrons provided by the decomposition of glycogen and fatty acid polymers increased the Coulombic efficiencies of TS to >100%. The tail current produced by spontaneous metabolic compensation showed a trend of convergent exponential decay, independent of BOD concentration. Therefore, we proposed the TS prediction model (TSPM) to predict Coulombic yield, which shortened BOD measurement time by 96% (to ∼0.5 h) with deviation <4 mg/L when using real domestic wastewater. Our findings on current output in TS give insights into bacterial substrate storage and consumption, as well as regulation in substrate-deficient environment, and provide a basis for developing BOD sensors.


Asunto(s)
Técnicas Biosensibles , Aguas Residuales , Biopelículas , Bacterias/metabolismo , Oxígeno/análisis , Polímeros
13.
Methods ; 220: 69-78, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37951559

RESUMEN

Continuous exposure to toxic pollutants highlights the need for sensitive detection technologies that can be rapidly applied in the current world for quick screening of real samples. Bisphenol A (BPA) is one of the most common environmental contaminants, and it has the potential to harm both the environment and human health, notably causing reproductive disorders, cancer, heart disease, infertility, mental disorders, etc. Thus, significant attention has been paid to the detection of BPA and microplastics to promote food safety, environmental health, and human health on a sustainable earth. Among the current technologies, microfluidic based systems have garnered a lot of interest as future diagnostic tools for healthcare applications. Microfluidic devices can be deployed for quick screening and real-time monitoring, with inherent advantages like portability, miniaturisation, highly sensing tool and ease of integration with various detection systems. Optical and electrochemical sensors are two major analytical tools found in almost all microfluidic-based devices for ultrasensitive BPA and microplastics determination. In this review, we have evaluated and discussed microfluidic-based detection methods for BPA and microplastics.


Asunto(s)
Microfluídica , Microplásticos , Humanos , Plásticos , Compuestos de Bencidrilo , Técnicas Electroquímicas
14.
Anal Bioanal Chem ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38802680

RESUMEN

Mechanotransduction is the essential process that cells convert mechanical force into biochemical responses, and electrochemical sensor stands out from existing techniques by providing quantitative and real-time information about the biochemical signals during cellular mechanotransduction. However, the intracellular biochemical response evoked by mechanical force has been poorly monitored. In this paper, we report a method to apply local stretch on single cell and simultaneously monitor the ensuing intracellular biochemical signals. Specifically, a ferromagnetic micropipette was fabricated to locally stretch a single cell labeled with Fe3O4 nanoparticles under the external magnetic field, and the SiC@Pt nanowire electrode (SiC@Pt NWE) was inserted into the cell to monitor the intracellular hydrogen peroxide (H2O2) production induced by the local stretch. As a proof of concept, this work quantitatively investigated the elevated amount of H2O2 levels in single endothelial cell under different stretching amplitudes. This work puts forward a new research modality to manipulate and monitor the mechanotransduction at the single-cell level.

15.
Anal Bioanal Chem ; 416(1): 265-276, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37957328

RESUMEN

As a central neurotransmitter, DA (dopamine) plays a vital part in human metabolism, and its accurate detection is of great significance in disease diagnosis. In this work, we used Cu/Co bimetallic metal-organic frameworks (MOFs) as templates and gold nanoparticles (AuNPs) to construct novel nanocomposite coral-like CuCo2O4@AuNPs with strong peroxidase activity and electrochemical response. The coral-like CuCo2O4@AuNPs showed excellent peroxidase activity, and the Km value was as low as 0.358 mM. In the presence of H2O2, the colorless substrate 3,3',5,5', -tetramethylbenzidine (TMB) can be catalytically oxidized into a blue product. Simultaneously, coral-like CuCo2O4@AuNPs, as an electroactive substance, possess strong electrocatalytic activity, which enhances the electron-transfer rate and promotes excellent current response. In the presence of DA, coral-like CuCo2O4@AuNPs can catalyze the oxidation of DA to dopaquinone, which further enhances the electrochemical signal. In addition, DA captures hydroxyl radicals and inhibits the oxidation of TMB, resulting in an obvious color change (blue turns colorless) and realizing colorimetric detection with the naked eye. On this basis, we successfully established a dual-mode colorimetric/electrochemical sensor using coral-like CuCo2O4@AuNP nanocomposites as a dual-signal probe. Combining colorimetric and electrochemical detection, the sensor achieved a wide linear range (0-1 mM) and a low detection limit (0.07 µM) for DA concentration. It was also successfully used for the detection of DA in human serum and urine with good results. In summary, this work provides an intuitive, economical, sensitive, and promising platform for DA detection.


Asunto(s)
Antozoos , Nanopartículas del Metal , Animales , Humanos , Dopamina , Oro/química , Colorimetría/métodos , Nanopartículas del Metal/química , Peróxido de Hidrógeno , Límite de Detección , Peroxidasas
16.
Anal Bioanal Chem ; 416(6): 1505-1515, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38267586

RESUMEN

This study focuses on the detection of ethyl methyl phosphonic acid (EMPA), a metabolite of the banned organophosphorus nerve agent VX. We developed an electrochemical sensor utilizing the molecularly imprinted polymer (MIP) based on 4-aminobenzoic acid (4-ABA) and tetraethyl orthosilicate for the selective detection of EMPA in human plasma and urine samples. The 4-ABA@EMPA/MIP/GCE sensor was constructed by a thermal polymerization process on a glassy carbon electrode and sensor characterization was performed by cyclic voltammetry and electrochemical impedance spectroscopy. The 4-ABA@EMPA/MIP/GCE sensor demonstrated impressive linear ranges 1.0 × 10-10 M-2.5 × 10-9 M for the standard solution, 1.0 × 10-10 M-2.5 × 10-9 M for the urine sample, and 1.0 × 10-10 M-1 × 10-9 M of EMPA for the plasma sample with outstanding detection limits of 2.75 × 10-11 M (standard solution), 2.11 × 10-11 M (urine), and 2.36 × 10-11 M (plasma). The sensor exhibited excellent recovery percentages ranging from 99.86 to 101.30% in urine samples and 100.62 to 101.08% in plasma samples. These findings underscore the effectiveness of the 4-ABA@EMPA/MIP/GCE as a straightforward, highly sensitive, and selective interface capable of detecting the target analyte EMPA in human plasma and urine samples.


Asunto(s)
Antracenos , Impresión Molecular , Agentes Nerviosos , Organofosfonatos , Compuestos Organotiofosforados , Humanos , Polímeros Impresos Molecularmente , Polímeros/química , Compuestos Organofosforados , Técnicas Electroquímicas/métodos , Impresión Molecular/métodos , Electrodos , Límite de Detección
17.
Anal Bioanal Chem ; 416(9): 2261-2275, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38117322

RESUMEN

Molecularly imprinted polymers (MIPs) rely on synthetic engineered materials able to selectively bind and intimately recognise a target molecule through its size and functionalities. The way in which MIPs interact with their targets, and the magnitude of this interaction, is closely linked to the chemical properties derived during the polymerisation stages, which tailor them to their specific target. Hence, MIPs are in-deep studied in terms of their sensitivity and cross-reactivity, further being used for monitoring purposes of analytes in complex analytical samples. As MIPs are involved in sensor development within different approaches, a systematic optimisation and rational data-driven sensing is fundamental to obtaining a best-performant MIP sensor. In addition, the closer integration of MIPs in sensor development requires that the inner properties of the materials in terms of sensitivity and selectivity are maintained in the presence of competitive molecules, which focus is currently opened. Identifying computational models capable of predicting and reporting the best-performant configuration of electrochemical sensors based on MIPs is of immense importance. The application of chemometrics using design of experiments (DoE) is nowadays increasingly adopted during optimisation problems, which largely reduce the number of experimental trials. These approaches, together with the emergent machine learning (ML) tool in sensor data processing, represent the future trend in design and management of point-of-care configurations based on MIP sensing. This review provides an overview on the recent application of chemometrics tools in optimisation problems during development and analytical assessment of electrochemical sensors based on MIP receptors. A comprehensive discussion is first presented to cover the recent advancements on response surface methodologies (RSM) in optimisation studies of MIPs design. Therefore, the recent advent of machine learning in sensor data processing will be focused on MIPs development and analytical detection in sensors.

18.
Environ Res ; 246: 118071, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38163546

RESUMEN

Herein, we present the exceptional performance of FeCx-coated carbon sheets (FC) derived from the pyrolysis of waste biomass as a bifunctional catalyst for electrochemical detection and catalytic reduction of 4-nitrophenol (4-NP). Despite having a lower surface area, larger particle size, and lesser N content, the FC material prepared at a calcination temperature of 900 °C (FC900) outperforms the other samples. Deeper investigations revealed that the FC900 efficiently facilitates the charge transfer process and enhances the diffusion rate of 4-NP, leading to increased surface coverage of 4-NP on the surface of FC900. Additionally, relatively weaker interactions between 4-NP and FC900 allow the facile adsorption and desorption of reaction intermediates. Due to the synergetic interplay of these factors, FC900 exhibited a linear response to changes in 4-NP concentration from 1 µM to 100 µM with a low limit of detection (LOD) of 84 nM (S/N = 3) and high sensitivity of 12.15 µA µM-1 cm-2. Importantly, it selectively detects 4-NP in the presence of five times more concentrated 2-aminophenol, 4-aminophenol, catechol, resorcinol, and hydroquinone and ten times more concentrated metal salts such as Na2SO4. NaNO3, KCl, CuCl2, and CaCl2. Moreover, FC900 can accurately detect micromolar levels of 4-NP in river water with high recovery values (99.8-103.5 %). In addition, FC900 exhibited outstanding catalytic activity in reducing 4-NP to 4-aminophenol (4-AP), achieving complete conversion within 8 min with a high-rate constant of 0.42 min-1. FC900 also shows high recyclability in six consecutive catalytic reactions due to Fe magnetic property.


Asunto(s)
Aminofenoles , Carbono , Carbón Orgánico , Nitrofenoles
19.
Environ Res ; 245: 117369, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37827372

RESUMEN

Using poly (vanillin-co-chitosan)/functionalized MWCNTs/GCE (PV-CS/f-MWCNTs/GCE) as a polymeric nanocomposite modified electrode, the present investigation has been conducted on the electrochemical detection of α-lipoic acid (α-LA) to prevent the activation of microglia inflammation of the nervous system. The manufacture of modified polymeric nanocomposite electrodes was carried out using the established electropolymerization process. Field emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD) analyses of structure revealed that the electropolymerization of poly (vanillin-co-chitosan) on the surface of the f-MWCNTs modified electrode was successful. Vanillin-co-chitosan electropolymerization on f-MWCNTs as electroactive sheets can enhance the signal for α-LA electrochemical sensors, according to research on the electrochemical characteristics utilizing cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methodologies. The PV-CS/f-MWCNTs/GCE demonstrated that it had a sensitivity of 0.04664 µA/µM, a detection limit of 0.012 µM, and an excellent response, linear range, and wide linear range to α-LA from 0 to 3000 µM. The results of the application of PV-CS/f-MWCNTs/GCE for determining the concentration of α-LA in a prepared real sample of human serum by DPV and human lipoic acid ELISA Kit analyses via standard addition method illustrated the substantial conformity between the findings of both assays. The results of the DPV analyses resulted in acceptable recovery values (97.60%-99.10%) and appropriate values of the Relative Standard Deviation (RSD) (3.58%-5.07%), which demonstrated the great applicability and accuracy of the results of PV-CS/f-MWCNTs/GCE for determining α-LA concentration in biological fluids and pharmaceutical specimens.


Asunto(s)
Benzaldehídos , Quitosano , Nanocompuestos , Ácido Tióctico , Humanos , Quitosano/química , Enfermedades Neuroinflamatorias , Nanocompuestos/química , Electrodos
20.
Environ Res ; 241: 117655, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37980995

RESUMEN

The synergetic effect between dual oxides in binary metal oxides (BMO) makes them promising electrode materials for the detection of toxic chemicals, and biological compounds. In addition, the interaction between the cations and anions of diverse metals in BMO tends to create more oxygen vacancies which are beneficial for energy storage devices. However, specifically targeted synthesis of BMO is still arduous. In this work, we prepared a nickel oxide/tin oxide composite (NiO/SnO2) through a simple solvothermal technique. The crystallinity, specific surface area, and morphology were fully characterized. The synthesized BMO is used as a bifunctional electrocatalyst for the electrochemical detection of dopamine (DPA) and for the hydrogen evolution reaction (HER). As expected, the active metals in the NiO/SnO2 composite afforded a higher redox current at a reduced redox potential with a nanomolar level detection limit (4 nm) and excellent selectivity. Moreover, a better recovery rate is achieved in the real-time detection of DPA in human urine and DPA injection solution. Compared to other metal oxides, NiO/SnO2 composite afforded lower overpotential (157 mV @10 mA cm-2), Tafel slope (155 mV dec-1), and long-term durability, with a minimum retention rate. These studies conclude that NiO/SnO2 composite can act as a suitable electrode modifier for electrochemical sensing and the HER.


Asunto(s)
Dopamina , Óxidos , Humanos , Catálisis , Electrodos , Hidrógeno
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda