Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 1.439
Filtrar
Más filtros

Tipo del documento
Publication year range
1.
Annu Rev Phys Chem ; 75(1): 509-534, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38941525

RESUMEN

The ability of nanophotonic cavities to confine and store light to nanoscale dimensions has important implications for enhancing molecular, excitonic, phononic, and plasmonic optical responses. Spectroscopic signatures of processes that are ordinarily exceedingly weak such as pure absorption and Raman scattering have been brought to the single-particle limit of detection, while new emergent polaritonic states of optical matter have been realized through coupling material and photonic cavity degrees of freedom across a wide range of experimentally accessible interaction strengths. In this review, we discuss both optical and electron beam spectroscopies of cavity-coupled material systems in weak, strong, and ultrastrong coupling regimes, providing a theoretical basis for understanding the physics inherent to each while highlighting recent experimental advances and exciting future directions.

2.
Nano Lett ; 24(18): 5610-5617, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38669343

RESUMEN

Halide perovskites (HPs) metasurfaces have recently attracted significant interest due to their potential to not only further enhance device performance but also reveal the unprecedented functionalities and novel photophysical properties of HPs. However, nanopatterning on HPs is critically challenging as they are readily destructed by the organic solvents in the standard lithographic processes. Here, we present a novel, subtle, and fully nondestructive HPs metasurface fabrication strategy based on cryogenic electron-beam writing. This technique allows for high-precision patterning and in situ imaging of HPs with excellent compatibility. As a proof-of-concept, broadband absorption enhanced metasurfaces were realized by patterning nanopillar arrays on CH3NH3PbI3 film, which results in photodetectors with approximately 14-times improvement on responsivity and excellent stability. Our findings highlight the great feasibility of cryogenic electron-beam writing for producing perovskite metasurface and unlocking the unprecedented photoelectronic properties of HPs.

3.
Nano Lett ; 24(29): 8866-8871, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-38976330

RESUMEN

Access to intrinsic properties of a 2D material is challenging due to the absence of a bulk that would dominate over surface contamination, and this lack of bulk also precludes effective conventional cleaning methods that are almost always sacrificial. Suspended graphene and carbon contaminants represent the most salient challenge. This work has achieved ultraclean graphene, attested by electron energy loss (EEL) spectra unprecedentedly exhibiting fine-structure features expected from bonding and band structure. In the cleaning process in a transmission electron microscope, radicals generated by radiolysis of intentionally adsorbed water remove organic contaminants, which would otherwise be feedstock of the notorious electron irradiation induced carbon deposition. This method can be readily adapted to other experimental settings and other materials to enable previously inhibited undertakings that rely on the intrinsic properties or ultimate thinness of 2D materials. Importantly, the method is surprisingly simple and robust, easily implementable with common lab equipment.

4.
Small ; 20(6): e2305655, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37771195

RESUMEN

Na2 Ti3 O7 is considered one of the most promising anode materials for sodium ion batteries due to its superior safety, environmental friendliness, and low manufacturing cost. However, its structural stability and reaction mechanism still have not been fully explored. As the electron beam irradiation introduces a similar impact on the Na2 Ti3 O7 anode as the extraction of Na+ ions during the battery discharge process, the microstructure evolution of the materials is investigated by advanced electron microscopy techniques at the atomic scale. Anisotropic amorphization is successfully observed. Through the integrated differential phase contrast-scanning transmission electron microscopy technique and density functional theory calculation, a phase transition pathway involving a new phase, Na2 Ti24 O49 , is proposed with the reduction of Na atoms. Additionally, it is found that the amorphization is dominated by the surface energy and electron dose rate. These findings will deepen the understanding of structural stability and deintercalation mechanism of the Na2 Ti3 O7 anode, providing new insight into exploring the failure mechanism of electrode materials.

5.
Small ; 20(21): e2309931, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38102094

RESUMEN

Skin, characterized by its distinctive gradient structure and interwoven fibers, possesses remarkable mechanical properties and highly sensitive attributes, enabling it to detect an extensive range of stimuli. Inspired by these inherent qualities, a pioneering approach involving the crosslinking of macromolecules through in situ electron beam irradiation (EBI) is proposed to fabricate gradient ionogels. Such a design offers remarkable mechanical properties, including excellent tensile properties (>1000%), exceptional toughness (100 MJ m-3), fatigue resistance, a broad temperature range (-65-200°C), and a distinctive gradient modulus change. Moreover, the ionogel sensor exhibits an ultra-fast response time (60 ms) comparable to skin, an incredibly low detection limit (1 kPa), and an exceptionally wide detection range (1 kPa-1 MPa). The exceptional gradient ionogel material holds tremendous promise for applications in the field of smart sensors, presenting a distinct strategy for fabricating flexible gradient materials.

6.
Small ; 20(30): e2309285, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38402441

RESUMEN

An amorphous carbon deposition layer (CDL) with nanoscale thickness induced by scanning electron microscope (SEM) electron beam is studied as a carbon-based protective layer on copper (Cu). CDL is prepared by inducing the deposition of pollutants or hydrocarbons in the cavity of SEM through electron beam irradiation (EBI). Wrinkles and cracks will not form and the interfacial spacing of CDL/Cu is smaller than Graphene/Cu (Gr/Cu). The thickness and coverage of the interfacial oxide layer of CDL/Cu are all smaller than that of the Gr/Cu after the same oxidation conditions. Characterization of Raman mapping also demonstrates that CDL shows better oxidation inhibition effects than graphene. The structure of CDL is determined to be C = C and C = O, CH3- and C-O can be loaded vertically on CDL. Density functional theory (DFT) is employed for demonstrating the smaller interfacial gap of CDL/Cu, less wrinkles and cracks and larger adsorbing energy of water/oxygen compared with Gr/Cu. Molecular dynamic (MD) simulation also indicates that the diffusion of water or oxygen into CDL/Cu is more difficult and the oxidation of Cu covered by CDL is well suppressed. This work provides a new approach for the study of carbon-based antioxidant materials on Cu.

7.
Small ; : e2403169, 2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38973079

RESUMEN

Nanopatterning on biomaterials has attracted significant attention as it can lead to the development of biomedical devices capable of performing diagnostic and therapeutic functions while being biocompatible. Among various nanopatterning techniques, electron-beam lithography (EBL) enables precise and versatile nanopatterning in desired shapes. Various biomaterials are successfully nanopatterned as bioresists by using EBL. However, the use of high-energy electron beams (e-beams) for high-resolutive patterning has incorporated functional materials and has caused adverse effects on biomaterials. Moreover, the scattering of electrons not absorbed by the bioresist leads to proximity effects, thus deteriorating pattern quality. Herein, EBL-based nanopatterning is reported by inducing molecular degradation of amorphous silk fibroin, followed by selectively inducing secondary structures. High-resolution EBL nanopatterning is achievable, even at low-energy e-beam (5 keV) and low doses, as it minimizes the proximity effect and enables precise 2.5D nanopatterning via grayscale lithography. Additionally, integrating nanophotonic structures into fluorescent material-containing silk allows for fluorescence amplification. Furthermore, this post-exposure cross-linking way indicates that the silk bioresist can maintain nanopatterned information stored in silk molecules in the amorphous state, utilizing for the secure storage of nanopatterned information as a security patch. Based on the fabrication technique, versatile biomaterial-based nanodevices for biomedical applications can be envisioned.

8.
Small ; : e2401426, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38686686

RESUMEN

The current high-capacity lithium-ion batteries (LIBs), reliant on flammable liquid electrolytes (LEs) and nickel-rich cathodes, are plagued by safety hazards, especially the risk of hazardous gas release stemming from internal side reactions. To address these safety concerns, an electron beam (E-beam)-induced gel polymer electrolyte (E-Gel) is introduced, employing dipentaerythritol hexaacrylate (DPH) as a bi-functional cross-linkable additive (CIA). The dual roles of DPH are exploited through a strategically designed E-beam irradiation process. Applying E-beam irradiation on the pre-cycled cells allows DPH to function as an additive during the initial cycle, establishing a protective layer on the surface of the anode and cathode and as a cross-linker during the E-beam irradiation step, forming a polymer framework. The prepared E-Gel with CIA has superior interfacial compatibility, facilitating lithium-ion diffusion at the electrode/E-Gel interface. The electrochemical assessment of 1.2 Ah pouch cells demonstrates that E-Gel substantially reduces gas release by 2.5 times compared to commercial LEs during the initial formation stage and ensures superior reversible capacity retention even after prolonged cycling at 55 °C. The research underscores the synergy of bifunctional CIA with E-beam technology, paving the way for large-scale production of safe, high-capacity, and commercially viable LIBs.

9.
Catheter Cardiovasc Interv ; 103(1): 169-185, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37994240

RESUMEN

BACKGROUND: Vascular complications after percutaneous transfemoral transcatheter aortic valve implantation (TAVI) are associated with adverse clinical outcomes and remain a significant challenge. AIMS: The purpose of this review is to synthesize the existing evidence regarding the iliofemoral artery features predictive of vascular complications after TAVI on pre-procedural contrast-enhanced multidetector computed tomography (MDCT). METHODS: A systematic search was performed in Embase and Medline (Pubmed) databases. Studies of patients undergoing transfemoral TAVI with MDCT were included. Studies with only valve-in-valve TAVI, planned surgical intervention and those using fluoroscopic assessment were excluded. Data on study cohort, procedural characteristics and significant predictors of vascular complications were extracted. RESULTS: We identified 23 original studies involving 8697 patients who underwent TAVI between 2006 and 2020. Of all patients, 8514 (97.9%) underwent percutaneous transfemoral-TAVI, of which 8068 (94.8%) had contrast-enhanced MDCT. The incidence of major vascular complications was 6.7 ± 4.1% and minor vascular complications 26.1 ± 7.8%. Significant independent predictors of major and minor complications related to vessel dimensions were common femoral artery depth (>54 mm), sheath-to-iliofemoral artery diameter ratio (>0.91-1.19), sheath-to-femoral artery diameter ratio (>1.03-1.45) and sheath-to-femoral artery area ratio (>1.35). Substantial iliofemoral vessel tortuosity predicted 2-5-fold higher vascular risk. Significant iliofemoral calcification predicted 2-5-fold higher risk. The iliac morphology score was the only hybrid scoring system with predictive value. CONCLUSIONS: Independent iliofemoral predictors of access-site complications in TAVI were related to vessel size, depth, calcification and tortuosity. These should be considered when planning transfemoral TAVI and in the design of future risk prediction models.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades Vasculares , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Enfermedades Vasculares/complicaciones
10.
Nanotechnology ; 35(36)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38848694

RESUMEN

Thermal rectifiers are essential in optimizing heat dissipation in solid-state devices to enhance energy efficiency, reliability, and overall performance. In this study, we experimentally investigate the thermal rectification phenomenon in suspended asymmetric graphene ribbons (GRs). The asymmetry within the graphene is introduced by incorporating periodic parallel nanoribbons on one side of the GR while maintaining the other side in a pristine form. Our findings reveal a substantial thermal rectification effect in these asymmetric graphene devices, reaching up to 45% at room temperature and increasing further at lower environmental temperatures. This effect is attributed to a significant thermal conductivity contrast between pristine graphene and nanoribbon graphene within the asymmetric structure. We observe that the incorporation of nanoribbons leads to a notable reduction in thermal conductivity, primarily due to phonon scattering and bottleneck effects near the nanoribbon edges. These findings suggest that graphene structures exhibiting asymmetry, facilitated by parallel nanoribbons, hold promise for effective heat management at the nanoscale level and the development of practical phononic devices.

11.
Nanotechnology ; 35(39)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38959870

RESUMEN

Electron beam lithography (EBL) stands out as a powerful direct-write tool offering nanometer-scale patterning capability and is especially useful in low-volume R&D prototyping when coupled with pattern transfer approaches like etching or lift-off. Among pattern transfer approaches, lift-off is preferred particularly in research settings, as it is cost-effective and safe and does not require tailored wet/dry etch chemistries, fume hoods, and/or complex dry etch tools; all-in-all offering convenient, 'undercut-free' pattern transfer rendering it useful, especially for metallic layers and unique alloys with unknown etchant compatibility or low etch selectivity. Despite the widespread use of the lift-off technique and optical/EBL for micron to even sub-micron scales, existing reports in the literature on nanofabrication of metallic structures with critical dimension in the 10-20 nm regime with lift-off-based EBL patterning are either scattered, incomplete, or vary significantly in terms of experimental conditions, which calls for systematic process optimization. To address this issue, beyond what can be found in a typical photoresist datasheet, this paper reports a comprehensive study to calibrate EBL patterning of sub-50 nm metallic nanostructures including gold nanowires and nanogaps based on a lift-off process using bilayer polymethyl-methacrylate as the resist stack. The governing parameters in EBL, including exposure dose, soft-bake temperature, development time, developer solution, substrate type, and proximity effect are experimentally studied through more than 200 EBL runs, and optimal process conditions are determined by field emission scanning electron microscope imaging of the fabricated nanostructures reaching as small as 11 nm feature size.

12.
Nanotechnology ; 35(40)2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-38981449

RESUMEN

Vertically grown nanowires (NWs) are a research interest in optoelectronics and photovoltaic applications due to their high surface to volume ratio and good light trapping capabilities. This study presents the effects of process and design parameters on self-catalyzed GaAsSbN NWs grown by plasma-assisted molecular beam epitaxy on patterned silicon substrates using electron beam lithography. Vertical alignment of the patterned NWs examined via scanning electron microscopy show the sensitivity of patterned NW growth to the parameters of NW diameter, pitch, dose time, etching techniques and growth plan. Diameters range from 90 nm to 250 nm. Pitch lengths of 200 nm, 400 nm, 600 nm, 800 nm, 1000 nm, and 1200 nm were examined. Dry etching of the oxide layer of the silicon substrate and PMMA coating is performed using reactive ion etching (RIE) for 20 s and 120 s respectively. Comparisons of different HF etch durations performed pre and post PMMA removal are presented. Additionally, the report of an observed surfactant effect in dilute nitride GaAsSbN NWs in comparison to non-nitride GaAsSb is presented. Optimizations to patterning, RIE, and HF etching are presented to obtain higher vertical yield of patterned GaAsSbN NWs, achieving ∼80% of the expected NWµm2. Room temperature and 4 K photoluminescence results show the effect of nitride incorporation for further bandgap tuning, and patterned pitch on the optical characteristics of the NWs which gives insights to the compositional homogeneity for NWs grown at each pitch length.

13.
J Appl Clin Med Phys ; 25(7): e14369, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38685586

RESUMEN

BACKGROUND: Particle accelerators, manufactured for delivering patient radiation treatment, require numerous and frequent quality assurance measures. One of those is the periodic check for electron energy stability. The American Association of Physicists in Medicine has established requirements for this procedure. The current recommendation is to perform a ratio of two ionization points, one at Dmax and another at a point approximately to the 50% depth, compared to a baseline as a relative check. PURPOSE: This ratio method is a sensitive measurement and sometimes produces results that are difficult to interpret or relate to acceptable tolerances. We sought to find a simple method that gives more stable results, which can be interpreted and related to energy changes. METHOD: We propose a method that takes two measurements on the descending portion of the shifted percent depth ionization (PDI) curves to calculate the slope, tangent to the I50 point, the point at which the ionization falls to 50% of its maximum value. We then used the slope measurement, compared to an established baseline, to relate energy. RESULTS: After collecting data over a 3-year period, we saw that standard deviations for the slope method have much less variability than the traditional ratio method. We were also able to correlate the slope results to ionization scans performed in water and found they were in better agreement than the traditional ratio method. CONCLUSION: The slope method does not require precise positioning since the slope remains relatively constant over the descending portion of the curve. Our data show that this results in an easier interpretative test of electron energy stability and delivers reliable feedback for quality assurance.


Asunto(s)
Electrones , Aceleradores de Partículas , Garantía de la Calidad de Atención de Salud , Garantía de la Calidad de Atención de Salud/normas , Aceleradores de Partículas/instrumentación , Aceleradores de Partículas/normas , Humanos , Control de Calidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Radiometría/normas
14.
J Appl Clin Med Phys ; 25(5): e14366, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38669190

RESUMEN

PURPOSE: Skin collimation is a useful tool in electron beam therapy (EBT) to decrease the penumbra at the field edge and minimize dose to nearby superficial organs at risk (OARs), but manually fabricating these collimation devices in the clinic to conform to the patient's anatomy can be a difficult and time intensive process. This work compares two types of patient-specific skin collimation (in-house 3D printed and vendor-provided machined brass) using clinically relevant metrics. METHODS: Attenuation measurements were performed to determine the thickness of each material needed to adequately shield both 6 and 9 MeV electron beams. Relative and absolute dose planes at various depths were measured using radiochromic film to compare the surface dose, flatness, and penumbra of the different skin collimation materials. RESULTS: Clinically acceptable thicknesses of each material were determined for both 6 and 9 MeV electron beams. Field width, flatness, and penumbra results between the two systems were very similar and significantly improved compared to measurements performed with no surface collimation. CONCLUSION: Both skin collimation methods investigated in this work generate sharp penumbras at the field edge and can minimize dose to superficial OARs compared to treatment fields with no surface collimation. The benefits of skin collimation are greatest for lower energy electron beams, and the benefits decrease as the measurement depth increases. Using bolus with skin collimation is recommended to avoid surface dose enhancement seen with collimators placed on the skin surface. Ultimately, the appropriate choice of material will depend on the desire to create these devices in-house or outsource the fabrication to a vendor.


Asunto(s)
Electrones , Órganos en Riesgo , Impresión Tridimensional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Piel , Humanos , Electrones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Piel/efectos de la radiación , Fantasmas de Imagen , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación
15.
J Appl Clin Med Phys ; 25(6): e14265, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38335230

RESUMEN

BACKGROUND: Electron out-of-field scatter is generally not given importance mainly in electron fields. However, this is important when applicator down and boost treatments are given usually at an angle from the central axis. The electron scatter dose is found to be far away from the central axis which could be easily ignored. PURPOSE: This study aims to investigate the out-of-field radiation doses from electron applicators and their effects on clinical treatment. By identifying the parameters that contribute to out-of-field doses and to explore potential strategies for reducing these doses in order to improve patient outcomes from modern machines. METHODS: Measurements were performed in water phantom using electron diode for modern Elekta and Varian machines. Dose profiles were acquired at surface and dmax with 0° and 90° collimation angle. Various gantry angles were also studied for some data with IC Profiler. The profiles were normalized with respect to the central axis dose. RESULTS: The scatter dose peaks were found at a distance between 11 and 28 cm from the central axis on all machines. However, the peak shifts to 15 cm at 90° collimator when beam is tilted. The position and intensity of the dose varies with depth, collimator, and gantry angles for both Elekta and Varian machines. Due to clearance issues more gantry angles were studied for Elekta applicator compared to Varian. In general, Varian TrueBeam has a lower scatter that Elekta Infinity. The 90° collimator angle has a higher scatter compared to zero degree for both machines. CONCLUSIONS: There are clinically significant peripheral doses around 3% of the central axis dose from the electron applicator. Elekta has a slightly higher scatter (3%) than Varian (2%) that peaks at 25 cm which is clinically important but often overlooked.


Asunto(s)
Electrones , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Dispersión de Radiación , Aceleradores de Partículas/instrumentación , Electrones/uso terapéutico , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias/radioterapia , Radioterapia de Intensidad Modulada/métodos , Radiometría/métodos
16.
Sensors (Basel) ; 24(12)2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38931492

RESUMEN

A staggered vane-shaped slot-line slow-wave structure (SV-SL SWS) for application in W-band traveling wave tubes (TWTs) is proposed in this article. In contrast to the conventional slot-line SWSs with dielectric substrates, the proposed SWS consists only of a thin metal sheet inscribed with periodic grooves and two half-metal enclosures, which means it can be easily manufactured and assembled and has the potential for mass production. This SWS not only solves the problem of the dielectric loading effect but also improves the heat dissipation capability of such structures. Meanwhile, the SWS design presented here covers a -15 dB S11 frequency range from 87.5 to 95 GHz. The 3-D simulation for a TWT based on the suggested SWS is also investigated. Under dual-electron injection conditions with a total voltage of 17.2 kV and a total current of 0.3 A, the maximum output power at 90 GHz is 200 W, with a 3 dB bandwidth up to 4 GHz. With a good potential for fabrication using microfabrication techniques, this structure can be a good candidate for millimeter-wave TWT applications.

17.
Sensors (Basel) ; 24(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38793828

RESUMEN

After the Fukushima nuclear power plant accident in 2011, many types of survey meters were used, including Geiger-Müller (GM) survey meters, which have long been used to measure ß-rays. Recently, however, a novel radiation survey meter that uses a plastic-scintillation sensor has been developed. Although manufacturers' catalog data are available for these survey meters, there have been no user reports on performance. In addition, the performance of commercial plastic-scintillation survey meters has not been evaluated. In this study, we experimentally compared the performance of a plastic-scintillation survey meter with that of a GM survey meter. The results show that the two instruments performed very similarly in most respects. The GM survey meter exhibited count losses when the radiation count rate was high, whereas the plastic-scintillation survey meter remained accurate under such circumstances, with almost no count loss at high radiation rates. For measurements at background rates (i.e., low counting rates), the counting rates of the plastic-scintillation and GM survey meters were similar. Therefore, an advantage of plastic-scintillation survey meters is that they are less affected by count loss than GM survey meters. We conclude that the plastic-scintillation survey meter is a useful ß-ray measuring/monitoring instrument.

18.
Nano Lett ; 23(6): 2339-2346, 2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36877825

RESUMEN

Direct-write processes enable the alteration or deposition of materials in a continuous, directable, sequential fashion. In this work, we demonstrate an electron beam direct-write process in an aberration-corrected scanning transmission electron microscope. This process has several fundamental differences from conventional electron-beam-induced deposition techniques, where the electron beam dissociates precursor gases into chemically reactive products that bond to a substrate. Here, we use elemental tin (Sn) as a precursor and employ a different mechanism to facilitate deposition. The atomic-sized electron beam is used to generate chemically reactive point defects at desired locations in a graphene substrate. Temperature control of the sample is used to enable the precursor atoms to migrate across the surface and bond to the defect sites, thereby enabling atom-by-atom direct writing.

19.
Nano Lett ; 23(10): 4242-4249, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37172322

RESUMEN

A rigorous account of quantum nonlocal effects is paramount for understanding the optical response of metal nanostructures and for designing plasmonic devices at the nanoscale. Here, we present a scheme for retrieving the quantum surface response of metals, encapsulated in the Feibelman d-parameters, from electron energy-loss spectroscopy (EELS) and cathodoluminescence (CL) measurements. We theoretically demonstrate that quantum nonlocal effects have a dramatic impact on EELS and CL spectra, in the guise of spectral shifts and nonlocal damping, when either the system size or the inverse wave vector in extended structures approaches the nanometer scale. Our concept capitalizes on the unparalleled ability of free electrons to supply deeply subwavelength near-fields and, thus, probe the optical response of metals at length scales in which quantum-mechanical effects are apparent. These results pave the way for a widespread use of the d-parameter formalism, thereby facilitating a rigorous yet practical inclusion of nonclassical effects in nanoplasmonics.

20.
Nano Lett ; 23(24): 11818-11826, 2023 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-38078871

RESUMEN

An atomic-scale understanding of the role of nonperiodic features is essential to the rational design of highly Li-ion-conductive solid electrolytes. Unfortunately, most solid electrolytes are easily damaged by the intense electron beam needed for atomic-resolution electron microscopy observation, so the reported in-depth atomic-scale studies are limited to Li0.33La0.56TiO3- and Li7La3Zr2O12-based materials. Here, we observe on an atomic scale a third type of solid electrolyte, Li1.3Al0.3Ti1.7(PO4)3 (LATP), through minimization of damage induced by specimen preparation. With this capability, LATP is found to contain large amounts of twin boundaries with an unusual asymmetric atomic configuration. On the basis of the experimentally determined structure, the theoretical calculations suggest that such asymmetric twin boundaries may considerably promote Li-ion transport. This discovery identifies a new entry point for optimizing ionic conductivity, and the method presented here will also greatly benefit the mechanistic study of solid electrolytes.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda