RESUMEN
BACKGROUND AND AIMS: The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE-marking) between 2000 and 2021. METHODS: Pre-specified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in seven different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time span covered 20 years (2000-21). Details of study design, patient population, intervention(s), and primary outcome(s) were summarized and assessed with respect to timing of the corresponding CE-mark approval. RESULTS: At least one prospective clinical trial was identified for 70% (50/71) of the pre-specified devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97 886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66 186 individuals) and 19% (57/308) randomized clinical trials (31 700 individuals). Pre-registration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 vs. 100 individuals, P < .001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 31 individuals) than after (median of 135 individuals) CE-mark approval (P < .001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-21. CONCLUSIONS: The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-21, were deemed insufficient. The majority of studies was non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE-mark certification.
Asunto(s)
Sistema Cardiovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Corazón , Prótesis e Implantes , Unión EuropeaRESUMEN
Material advances in soft bioelectronics, particularly those based on stretchable nanocompositesâfunctional nanomaterials embedded in viscoelastic polymers with irreversible or reversible bondsâhave driven significant progress in translational medical device research. The unique mechanical properties inherent in the stretchable nanocomposites enable stiffness matching between tissue and device, as well as its spontaneous mechanical adaptation to in vivo environments, minimizing undesired mechanical stress and inflammation responses. Furthermore, these properties allow percolative networks of conducting fillers in the nanocomposites to be sustained even under repetitive tensile/compressive stresses, leading to stable tissue-device interfacing. Here, we present an in-depth review of materials strategies, fabrication/integration techniques, device designs, applications, and translational opportunities of nanocomposite-based soft bioelectronics, which feature intrinsic stretchability, self-healability, tissue adhesion, and/or syringe injectability. Among many, applications to brain, heart, and peripheral nerves are predominantly discussed, and translational studies in certain domains such as neuromuscular and cardiovascular engineering are particularly highlighted.
Asunto(s)
Nanocompuestos , Nanocompuestos/química , Humanos , Prótesis e Implantes , Materiales Biocompatibles/química , Animales , Polímeros/química , ElectrónicaRESUMEN
INTRODUCTION: Not all patients experience debilitating symptoms during Atrial Fibrillation (AF), some are asymptomatic. The reasons for this inter- and intrasubject variability is unknown. PURPOSE: The study objective was NOAH characterize episode-level and clinical characteristics associated with symptomatic versus asymptomatic episodes of AF in patients with an implantable cardiac monitor (ICM). METHODS: Patients with an AF episode detected on an ICM between 2007 and 2021 with overlapping clinical data from aggregated Electronic Health Records in the Optum® deidentified data set were included. Symptomatic episodes were labeled in real-time by the patient. Heart rate (HR) at onset, mean HR, AF Evidence Score (a measure of beat-to-beat irregularity), episode duration and Activity Index were evaluated for association with symptom status using multivariable regression modeling. RESULTS: 11 267 patients had AF episodes with clinical data available. The 1776 (15.8%) patients who reported symptomatic AF episodes were younger (67 ± 12 years vs. 71 ± 11 years old, p < .001) and had fewer cardiovascular co-morbidities than patients with asymptomatic AF exclusively. Symptomatic episodes were longer (5.5 [2.4, 14.4] h vs. 3.7 [1.7, 11] h, p < .001), had higher mean HR (103 ± 22 bpm vs. 88 ± 22 bpm, p < .001) and higher AF evidence scores (98 ± 27 vs. 82 ± 24, p < .001). These features were independently associated with symptomatic episodes on multivariable regression analysis and per-subject analysis in patients who had both symptomatic and asymptomatic episodes. DISCUSSION: Episode-level characteristics differed between symptomatic AF episodes versus asymptomatic episodes in patients with ICMs. Symptomatic patients also had less comorbidities. These parameters may be useful in understanding variable symptomatic manifestation and remote stratification of AF episodes.
RESUMEN
BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.
Asunto(s)
Anticoagulantes , Estimulación Cardíaca Artificial , Heparina , Marcapaso Artificial , Humanos , Heparina/administración & dosificación , Heparina/efectos adversos , Masculino , Anciano , Femenino , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Tiempo , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Esquema de Medicación , Implantación de Prótesis/instrumentación , Implantación de Prótesis/efectos adversos , Diseño de PrótesisRESUMEN
BACKGROUND: A novel implantable sensor has been designed to measure the inferior vena cava (IVC) area accurately so as to allow daily monitoring of the IVC area and collapse to predict congestion in heart failure (HF). METHODS: A prospective, multicenter, single-arm, Early Feasibility Study enrolled 15 patients with HF (irrespective of ejection fraction) and with an HF event in the previous 12 months, an elevated NT-proBNP level, and receiving ≥ 40 mg of furosemide equivalent. Primary endpoints included successful deployment without procedure-related (30 days) or sensor-related complications (3 months) and successful data transmission to a secure database (3 months). Accuracy of sensor-derived IVC area, patient adherence, NYHA classification, and KCCQ were assessed from baseline to 3 months. Patient-specific signal alterations were correlated with clinical presentation to guide interventions. RESULTS: Fifteen patients underwent implantation: 66 ± 12 years; 47% female; 27% with HFpEF, NT-ProBNP levels 2569 (median, IQR: 1674-5187, ng/L; 87% NYHA class III). All patients met the primary safety and effectiveness endpoints. Sensor-derived IVC areas showed excellent agreement with concurrent computed tomography (R2â¯=â¯0.99, mean absolute errorâ¯=â¯11.15 mm2). Median adherence to daily readings was 98% (IQR: 86%-100%) per patient-month. A significant improvement was seen in NYHA class and a nonsignificant improvement was observed in KCCQ. CONCLUSIONS: Implantation of a novel IVC sensor (FIRE1) was feasible, uncomplicated and safe. Sensor outputs aligned with clinical presentations and improvements in clinical outcomes. Future investigation to establish the IVC sensor remote management of HF is strongly warranted.
RESUMEN
OBJECTIVE: This systematic review of literature aimed to evaluate the safety and efficacy of dual-chamber ICDs for LBBAP in patients with left bundle branch block (LBBB). METHODS: Digital databases were searched systematically to identify studies reporting the left bundle branch area pacing (LBBAP) with implantable cardioverter defibrillator (ICD) placement in patients with LBBB. Detailed study and patient-level baseline characteristics including the type of study, sample size, follow-up, number of cases, age, gender, and baseline characteristics were abstracted. RESULTS: In a total of three studies, 34 patients were included in this review. There was a significant improvement reported in QRS duration in all studies. The mean QRS duration at baseline was 170 ± 17.4 ms, whereas the follow-up QRS duration at follow-up was 121 ± 17.3 ms. Two studies reported a significant improvement of 50% in LVEF from baseline. No lead-related complications or arrhythmic events were recorded in any study. The findings of the systematic review suggest that dual-chamber ICD for LBBAP is a promising intervention for patients with heart conditions. CONCLUSION: The procedure offers significant improvements in QRS duration and LVEF, and there were no lead-related complications or arrhythmic events recorded in any of the studies.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Bloqueo de Rama/terapia , Resultado del Tratamiento , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular , Terapia de Resincronización Cardíaca/métodosRESUMEN
Cardiac device therapy provides not only treatment options for bradyarrhythmia but also advanced treatment for heart failure and preventive measures against sudden cardiac death. In heart failure treatment it enables synergistic reverse remodelling and reduces pharmacological side effects. Cardiac resynchronization therapy (CRT) has revolutionized the treatment of reduced left ventricular ejection fraction (LVEF) and left bundle branch block by decreasing the mortality and morbidity with improvement of the quality of life and resilience. Conduction system pacing (CSP) as an alternative method of physiological stimulation can improve heart function and reduce the risk of pacemaker-induced cardiomyopathy. Leadless pacers and subcutaneous/extravascular defibrillators offer less invasive options with lower complication rates. The prevention of infections through preoperative and postoperative strategies enhances the safety of these therapies.
Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Muerte Súbita Cardíaca/prevención & control , Medicina Basada en la Evidencia , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/prevención & control , Marcapaso Artificial , Resultado del TratamientoRESUMEN
BACKGROUND: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. METHODS: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. RESULTS: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. CONCLUSIONS: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.
Asunto(s)
Terapia por Estimulación Eléctrica , Músculo Esquelético , Humanos , Electromiografía , Electrodos Implantados , Músculo Esquelético/fisiología , Extremidad Inferior , Tecnología InalámbricaRESUMEN
BACKGROUND: Total Knee Arthroplasty (TKA) is frequently performed for advanced osteoarthritis, with patient-reported outcome measures (PROMs) traditionally reporting on efficacy. These subjective evaluations, although useful, may inaccurately reflect post-TKA activity levels. With technological advancements, smart implantable devices (SIDs) offer objective, real-time gait metrics, potentially providing a more accurate postoperative recovery assessment. This study compares these objective metrics with PROMs to evaluate TKA success more effectively. METHODS: We conducted a retrospective cohort study with 88 participants undergoing TKA using a SID. Eligible patients were aged 18 years or older and had advanced osteoarthritis. We excluded those who had bilateral TKAs, joint infections, or neuromuscular disease. The SID system collected daily gait metrics, including step count, distance traveled, walking speed, stride length, cadence, and functional knee range of motion. The PROMs, including Knee Injury and Osteoarthritis Outcome Score-Joint Replacement, Veterans Rand 12 Physical Component Summary, and Veterans Rand 12 Mental Component Summary, were analyzed against SID gait metrics. Among the 88 patients, 80 provided continuous data over 12 weeks. RESULTS: All gait metrics, except stride length, significantly increased at the 12-week point (P < .05). The PROMs also significantly improved postoperatively (P < .05). Initial low positive correlations between 12-week PROMs and SID metrics decreased after adjusting for demographic variables, leaving only weak correlations between the Veterans Rand 12 Physical Component Summary and Knee Injury and Osteoarthritis Outcome Score-Joint Replacement with functional knee range of motion (r = 0.389, P = .002; r = 0.311, P = .014, respectively), and Veterans Rand 12 Mental Component Summary with step count (r = 0.406, P = .001) and distance traveled (r = 0.376, P = .003). CONCLUSIONS: This study indicates that both PROMs and SID gait metrics show significant improvements post-TKA, though they correlate weakly with each other, suggesting a possible discrepancy between perceived recovery and actual functional improvement. The SID gait metrics might provide a valuable addition to traditional PROMs by offering an objective representation of physical capabilities unaffected by patient compliance or subjective perceptions of recovery. Further research is needed to validate these findings in larger populations and to explore whether integrating SID metrics can enhance long-term functional outcomes.
RESUMEN
In recent years, portable and wearable personal electronic devices have rapidly developed with increasing mass production and rising energy consumption, creating an energy crisis. Using batteries and supercapacitors with limited lifespans and environmental hazards drives the need to find new, environmentally friendly, and renewable sources. One idea is to harness the energy of human motion and convert it into electrical energy using energy harvesting devices-piezoelectric nanogenerators (PENGs), triboelectric nanogenerators (TENGs) and hybrids. They are characterized by a wide variety of features, such as lightness, flexibility, low cost, richness of materials, and many more. These devices offer the opportunity to use new technologies such as IoT, AI or HMI and create smart self-powered sensors, actuators, and self-powered implantable/wearable devices. This review focuses on recent examples of PENGs, TENGs and hybrid devices for wearable and implantable self-powered systems. The basic mechanisms of operation, micro/nano-scale material selection and manufacturing processes of selected examples are discussed. Current challenges and the outlook for the future of the nanogenerators are also discussed.
RESUMEN
INTRODUCTION: The risk of complications associated with transvenous ICDs make the subcutaneous implantable cardiac defibrillator (S-ICD) a valuable alternative in patients with adult congenital heart disease (ACHD). However, higher S-ICD ineligibility and higher inappropriate shock rates-mostly caused by T wave oversensing (TWO)- are observed in this population. We report a novel application of deep learning methods to screen patients for S-ICD eligibility over a longer period than conventional screening. METHODS: Adult patients with ACHD and a control group of normal subjects were fitted with a 24-h Holters to record their S-ICD vectors. Their T:R ratio was analysed utilising phase space reconstruction matrices and a deep learning-based model to provide an in-depth description of the T: R variation plot for each vector. T: R variation was compared statistically using t-test. RESULTS: 13 patients (age 37.4 ± 7.89 years, 61.5 % male, 6 ACHD and 7 control subjects) were enrolled. A significant difference was observed in the mean and median T: R values between the two groups (p < 0.001). There was also a significant difference in the standard deviation of T: R between both groups (p = 0.04). CONCLUSIONS: T:R ratio, a main determinant for S-ICD eligibility, is significantly higher with more tendency to fluctuate in ACHD patients when compared to a population with normal hearts. We hypothesise that our novel model could be used to select S-ICD eligible patients by better characterisation of T:R ratio, reducing the risk of TWO and inappropriate shocks in the ACHD patient cohort.
RESUMEN
Human beings have a greater need to pursue life and manage personal or family health in the context of the rapid growth of artificial intelligence, big data, the Internet of Things, and 5G/6G technologies. The application of micro biosensing devices is crucial in connecting technology and personalized medicine. Here, the progress and current status from biocompatible inorganic materials to organic materials and composites are reviewed and the material-to-device processing is described. Next, the operating principles of pressure, chemical, optical, and temperature sensors are dissected and the application of these flexible biosensors in wearable/implantable devices is discussed. Different biosensing systems acting in vivo and in vitro, including signal communication and energy supply are then illustrated. The potential of in-sensor computing for applications in sensing systems is also discussed. Finally, some essential needs for commercial translation are highlighted and future opportunities for flexible biosensors are considered.
Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Humanos , Materiales Biocompatibles , Inteligencia Artificial , Prótesis e ImplantesRESUMEN
Micro elastofluidics is an emerging research field that encompasses characteristics of conventional microfluidics and fluid-structure interactions. Micro elastofluidics is expected to enable practical applications, for instance, where direct contact between biological samples and fluid handling systems is required. Besides design optimization, choosing a proper material is critical to the practical use of micro elastofluidics upon interaction with biological interface and after its functional lifetime. Biodegradable polymers are one of the most studied materials for this purpose. Micro elastofluidic devices made of biodegradable polymers possess exceptional mechanical elasticity, excellent bio compatibility, and structural degradability into non-toxic products. This article provides an insightful and systematic review of the utilization of biodegradable polymers in digital and continuous-flow micro elastofluidics.
RESUMEN
INTRODUCTION: Cardiac Implantable Electronic Devices (CIEDs) are widely used for the management of advanced heart failure and ventricular arrhythmias. CIED-Infection (CIED-I) has very high mortality, especially in the subsets of patients with limited health-care access and delayed presentation. The purpose of this study is to identify the risk-predictors mortality in subjects with CIED-I. METHODS: We performed a retrospective cohort study of a regional database in patients presenting with CIED infections to tertiary care medical centers across Western New York, USA from 2012 to 2020. The clinical outcomes included recurrent device infection (any admission for CIED-I after the first hospitalization for device infection), septic complications (pulmonary embolism, respiratory failure, septic shock, decompensated HF, acute kidney injury) and mortality outcomes (death during hospitalization, within 30 days from CIED-I, and within 1 year from CIED-I). We studied associations between categorical variables and hard outcomes using χ2 tests and used one-way analysis of variance to measure between-groups differences. RESULTS: We identified 296 patients with CIED-I, among which 218 (74%) were male, 237 (80%) were white and the mean age at the time of infection was 69.2 ± 13.7 years. One-third of the patients were referred from the regional facilities. Staphylococcus aureus was responsible for most infections, followed by Enterococcus fecalis. On multivariate analysis, the covariates associated with significantly increased mortality risk included referral from regional facility (OR: 2.0;1.0-4.0), hypertension (Odds ratio, OR: 3.2;1.3-8.8), right ventricular dysfunction (OR: 2.6;1.2-5.1), end-stage renal disease (OR: 2.6;1.1-6.2), immunosuppression (OR: 11.4;2.5-53.3), and septic shock as a complication of CIED-I (OR: 3.9;1.3-10.8). CONCLUSION: Hypertension, right ventricular dysfunction, immunosuppression, and end-stage renal disease are associated with higher mortality after CIED-I. Disproportionately higher mortality was also noted in subjects referred from the regional facilities. This underscores the importance of early clinical risk-assessment, and the need for a robust referral infrastructure to improve patient outcomes.
Asunto(s)
Desfibriladores Implantables , Cardiopatías , Fallo Renal Crónico , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Choque Séptico , Disfunción Ventricular Derecha , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Choque Séptico/complicaciones , Cardiopatías/etiología , Factores de Riesgo , Fallo Renal Crónico/complicaciones , Infecciones Relacionadas con Prótesis/etiologíaRESUMEN
INTRODUCTION: Incomplete anchoring of the Watchman left atrial appendage closure (LAAO) device can result in substantial device migration or device embolization (DME) requiring percutaneous or surgical retrieval. METHODS: We performed a retrospective analysis of Watchman procedures (January 2016 through March 2021) reported to the National Cardiovascular Data Registry LAAO Registry. We excluded patients with prior LAAO interventions, no device released, and missing device information. In-hospital events were assessed among all patients and postdischarge events were assessed among patients with 45-day follow-up. RESULTS: Of 120 278 Watchman procedures, the in-hospital DME rate was 0.07% (n = 84) and surgery was commonly performed (n = 39). In-hospital mortality rate was 14% among patients with DME and 20.5% among patients who underwent surgery. In-hospital DME was more common: at hospitals with a lower median annual procedure volume (24 vs. 41 procedures, p < .0001), with Watchman 2.5 versus Watchman FLX devices (0.08% vs. 0.04%, p = .0048), with larger LAA ostia (median 23 vs. 21 mm, p = .004), and with a smaller difference between device and LAA ostial size (median difference 4 vs. 5 mm, p = .04). Of 98 147 patients with 45-day follow-up, postdischarge DME occurred in 0.06% (n = 54) patients and cardiac surgery was performed in 7.4% (n = 4) of cases. The 45-day mortality rate was 3.7% (n = 2) among patients with postdischarge DME. Postdischarge DME was more common among men (79.7% of events but 58.9% of all procedures, p = .0019), taller patients (177.9 vs. 172 cm, p = .0005), and those with greater body mass (99.9 vs. 85.5 kg, p = .0055). The rhythm at implant was less frequently AF among patients with DME compared to those without (38.9% vs. 46.9%, p = .0098). CONCLUSION: While Watchman DME is rare, it is associated with high mortality and frequently requires surgical retrieval, and a substantial proportion of events occur after discharge. Due to the severity of DME events, risk mitigation strategies and on-site cardiac surgical back-up are of paramount importance.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Masculino , Humanos , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Cuidados Posteriores , Alta del Paciente , Sistema de Registros , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo CardíacoRESUMEN
INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Péptido Natriurético Encefálico , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/metabolismo , Ecocardiografía Transesofágica , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/química , Apnea Obstructiva del Sueño/diagnóstico , Volumen Sistólico , Función Ventricular IzquierdaRESUMEN
AIMS: Natural language processing chatbots (NLPC) can be used to gather information for medical content. However, these tools contain a potential risk of misinformation. This study aims to evaluate different aspects of responses given by different NLPCs on questions about atrial fibrillation (AF) and clinical implantable electronic devices (CIED). METHODS AND RESULTS: Questions were entered into three different NLPC interfaces. Responses were evaluated with regard to appropriateness, comprehensibility, appearance of confabulation, absence of relevant content, and recommendations given for clinically relevant decisions. Moreover, readability was assessed by calculating word count and Flesch Reading Ease score. 52, 60, and 84% of responses on AF and 16, 72, and 88% on CIEDs were evaluated to be appropriate for all responses given by Google Bard, (GB) Bing Chat (BC) and ChatGPT Plus (CGP), respectively. Assessment of comprehensibility showed that 96, 88, and 92% of responses on AF and 92 and 88%, and 100% on CIEDs were comprehensible for all responses created by GB, BC, and CGP, respectively. Readability varied between different NLPCs. Relevant aspects were missing in 52% (GB), 60% (BC), and 24% (CGP) for AF, and in 92% (GB), 88% (BC), and 52% (CGP) for CIEDs. CONCLUSION: Responses generated by an NLPC are mostly easy to understand with varying readability between the different NLPCs. The appropriateness of responses is limited and varies between different NLPCs. Important aspects are often missed to be mentioned. Thus, chatbots should be used with caution to gather medical information about cardiac arrhythmias and devices.
Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Inteligencia Artificial , Factores de Riesgo , ElectrónicaRESUMEN
BACKGROUND: There is a lack of evidence regarding contemporary implantable cardioverter-defibrillator (ICD) battery longevity. Our aim was to assess battery longevity in ICDs in a real-world setting. METHODS: Retrospective cross-sectional single center study of a prospectively collected database of consecutive patients who underwent ICD implantation from January 2010 to December 2015. Clinical data and battery longevity of all manufacturers were collected. RESULTS: A total of 351 patients (84.6% males, mean age of 61 ± 12 years) were included in the study (292 VVI; 6 VDD; 53 DDD). All manufacturers (Abbott, Biotronik, Boston, Medtronic and Microport) were equally represented in the study (p = 0.110). Median battery longevity was 10.8 years (11 years for VVI and 8.5 for DDD). After a follow-up time of 5 years, 98% of VVI and DDD were still in service (vs. industry-projected longevity of 98%). During this time, 89 patients (25.4%) underwent device replacement - 69 patients (77.5%) due to battery depletion, 6 patients due to infection, 3 patients due to dysfunction and 13 patients due to upgrade to CRT-D. Patients with Medtronic or Biotronik ICDs had a greater probability of being replaced earlier due to battery depletion (Biotronik HR 6.87, 95% CI 2.54-18.58, p < 0.001; Medtronic HR 6.08, 95% CI 2.45-15.06 p < 0.001). CONCLUSIONS: VVI and DDD ICD battery longevity matched industry-projected longevity after 5 years of follow-up. Medtronic and Biotronik ICDs appeared to have an earlier battery depletion. Further randomized studies are required to ensure optimal care.
Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Falla de Equipo , Estudios Retrospectivos , Estudios Prospectivos , Estudios Transversales , Diseño de Equipo , Estimación de Kaplan-Meier , Factores de Tiempo , Remoción de DispositivosRESUMEN
BACKGROUND: Automated threshold measurements (ATM) and output adaptation improved safety and follow-up of cardiac implantable devices (CIED) in the last years. These algorithms were validated for conventional cardiac pacing; however, they were not suitable for permanent His Pacing. Left bundle branch area pacing (LBBAP) is an emerging technique to obtain physiologic cardiac stimulation; we tried to assess if ATM could be applied to this setting. METHODS: Consecutive patients receiving ATM-capable CIED and LBBAP in our hospital were enrolled in this prospective, observational trial; they were evaluated 3 months after implant, comparing pacing thresholds manually assessed and obtained via ATM. Subsequent remote follow-up was carried on when available. RESULTS: Forty-five patients were enrolled. ATM for LBBAP lead provided consistent results in all the patients and was therefore activated; mean value of manually obtained LBBAP capture threshold was 0.66 ± 0.19 V versus ATM of 0.64 ± 0.19 V. TOST analysis showed equivalence of the two measures (p = .66). At subsequent follow-up (mean follow up 7.7 ± 3.2 months), ATM was effective in assessing pacing thresholds and no clinical adverse event was observed. CONCLUSIONS: ATM algorithms proved equivalent to manual testing in determining capture threshold and were reliably employed in patients receiving LBBAP CIED.
Asunto(s)
Sistema de Conducción Cardíaco , Tabique Interventricular , Humanos , Proyectos Piloto , Estudios Prospectivos , Trastorno del Sistema de Conducción Cardíaco , Algoritmos , Electrocardiografía , Estimulación Cardíaca Artificial , Fascículo Atrioventricular , Resultado del TratamientoRESUMEN
PURPOSE OF REVIEW: This review offers an overview of the evidence in diagnostic and therapeutic applications of remote monitoring implantable devices. RECENT FINDINGS: Remote monitoring of cardiac implantable devices has become more and more popular in recent years as healthcare is moving towards a more patient centralized system. For heart failure patients with an ICD or pacemaker, there is controversial evidence regarding improvements in the clinical outcome, e.g., reduction of hospitalization rates or overall mortality. New developments as hemodynamic remote monitoring via measurement of the pulmonary artery pressure are promising technical achievements showing encouraging results. In cardiac remote monitoring of syncope and arrhythmias, implantable loop recorder plays an important role in diagnostic algorithms. Although there is controversial evidence according to remote monitoring of implantable devices, its use is rapidly expanding, giving healthcare providers the opportunity to react promptly to worsening of their patients. Adequate evaluation of the data created by remote monitoring systems remains an unsolved challenge of contemporary healthcare services.