Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Europace ; 24(11): 1788-1799, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35851611

RESUMEN

AIMS: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans. METHODS AND RESULTS: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes. Episodes of self-terminated PVT/VF lasted 8.6 s [95% confidence interval (CI): 8.1-9.1] and shock-terminated lasted 13.9 s (13.6-14.3) (P < 0.001). Recordings from patients with primarily electrical pathologies displayed higher DF and RI values than those from patients with primarily structural pathologies (P < 0.05) independently of ventricular function or antiarrhythmic drug therapy. Regardless of the underlying pathology, the average DF and RI intensities were lower in self-terminated than shock-terminated episodes [DF: 3.67 (4.04-4.58) vs. 4.32 (3.46-3.93) Hz, P < 0.001; RI: 0.53 (0.48-0.56) vs. 0.63 (0.60-0.65), P < 0.001]. In a multivariate analysis controlled by the type of pathology and clinical variables, regularity remained an independent predictor of self-termination [hazard ratio: 0.954 (0.928-0.980)]. Receiver operating characteristic (ROC) curve analysis of DF and RI intensities demonstrated increased predictability for self-termination in time with 95% CI above the 0.5 cut-off limit at about t = 8.6 s and t = 6.95 s, respectively. CONCLUSION: Consistent with the notion that fast organized sources maintain PVT/VF in humans, reduction of frequency and regularity correlates with early self-termination. Our findings might help generate ICD methods aiming to reduce inappropriate shock deliveries.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia
2.
Heart Vessels ; 32(3): 333-340, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27469320

RESUMEN

Previous studies showed that continuous anticoagulation or single antiplatelet therapy during implantations of cardiac implantable electronic devices (CIED) was relatively safe. However, the safety of continuous multi antithrombotic therapy (AT) in patients undergoing CIED interventions has not been clearly defined. We sought to evaluate the safety of this therapy during CIED implantations. A total of 300 consecutive patients (mean 69 years old, 171 males) with CIED implantations were enrolled in this study. The patients were divided into 6 groups [No-AT, oral anticoagulant therapy (OAT), single antiplatelet therapy (SAPT), OAT and SAPT, dual antiplatelet therapy (DAPT), triple AT (TAT)], and the perioperative complications were evaluated. Clinically significant pocket hematomas (PH) were defined as PH needing surgical intervention, prolonged hospitalizations, interruption of AT, or blood product transfusions. There were 129, 89, 49, 20, 10, and 3 patients in No-AT, OAT, SAPT, OAT + SAPT, DAPT, and TAT groups, respectively. The occurrence of clinically significant PH and thromboembolism did not differ among 6 groups (p = 0.145 and p = 0.795, respectively). However, high HAS-BLED score and valvular heart disease (VHD) were associated with clinically significant PH (p = 0.014 and p = 0.015, respectively). Continuous multi AT may be tolerated, but patients with high HAS-BLED score or VHD would require a careful attention during CIED implantations.


Asunto(s)
Anticoagulantes/uso terapéutico , Desfibriladores Implantables/efectos adversos , Hematoma/epidemiología , Marcapaso Artificial/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Tromboembolia/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Femenino , Hematoma/etiología , Hemorragia/inducido químicamente , Humanos , Japón , Modelos Logísticos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Tromboembolia/etiología
3.
Heart ; 108(1): 22-28, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33674353

RESUMEN

OBJECTIVE: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with a risk of sudden cardiac death. Optimal risk stratification is still under debate. The main purpose of this long-term, single-centre observation was to analyse predictors of appropriate and inappropriate implantable cardioverter-defibrillator (ICD) interventions in the population of patients with ARVC with a high risk of life-threatening arrhythmias. METHODS: The study comprised 65 adult patients (median age 40 years, 48 men) with a definite diagnosis of ARVC who received ICD over a time span of 20 years in primary (40%) or secondary (60%) prevention of sudden cardiac death. The study endpoints were first appropriate and inappropriate ICD interventions (shock or antitachycardia pacing) after device implantation. RESULTS: During a median follow-up of 7.75 years after ICD implantation, nine patients died and six individuals underwent heart transplantation. Appropriate ICD interventions occurred in 43 patients (66.2%) and inappropriate ICD interventions in 18 patients (27.7%). Multivariable analysis using cause-specific hazard model identified three predictors of appropriate ICD interventions: right ventricle dysfunction (cause-specific HR 2.85, 95% CI 1.56 to 5.21, p<0.001), age <40 years at ICD implantation (cause-specific HR 2.37, 95% CI 1.13 to 4.94, p=0.022) and a history of sustained ventricular tachycardia (cause-specific HR 2.55, 95% CI 1.16 to 5.63, p=0.020). Predictors of inappropriate ICD therapy were not found. Complications related to ICD implantation occurred in 12 patients. CONCLUSIONS: Right ventricle dysfunction, age <40 years and a history of sustained ventricular tachycardia were predictors of appropriate ICD interventions in patients with ARVC. The results may be used to improve risk stratification before ICD implantation.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Taquicardia Ventricular , Adulto , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/terapia
4.
Heart ; 106(9): 671-676, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31924714

RESUMEN

OBJECTIVE: There are large geographical differences in implantable cardioverter defibrillator (ICD) implantation rates for reasons not completely understood. In an increasingly multiethnic population, we sought out to investigate whether ethnicity influenced ICD implantation rates. METHODS: This was a retrospective, cohort study of new ICD implantation or upgrade to ICD from January 2006 to February 2019 in recipients of Caucasian or South Asian ethnicity at a single tertiary centre in the UK. Data were obtained from a routinely collected local registry. Crude rates of ICD implantation were calculated for the population of Leicestershire county and were age-standardised to the UK population using the UK National Census of 2011. RESULTS: The Leicestershire population was 980 328 at the time of the Census, of which 761 403 (77.7%) were Caucasian and 155 500 (15.9%) were South Asian. Overall, 2650 ICD implantations were performed in Caucasian (91.9%) and South Asian (8.1%) patients. South Asians were less likely than Caucasians to receive an ICD (risk ratio (RR) 0.43, 95% CI 0.37 to 0.49, p<0.001) even when standardised for age (RR 0.75, 95% CI 0.74 to 0.75, p<0.001). This remained the case for primary prevention indication (age-standardised RR 0.91, 95% CI 0.90 to 0.91, p<0.001), while differences in secondary prevention ICD implants were even greater (age-standardised RR 0.49, 95% CI 0.48 to 0.50, p<0.001). CONCLUSION: Despite a universal and free healthcare system, ICD implantation rates were significantly lower in the South Asian than the Caucasian population residing in the UK. Whether this is due to cultural acceptance or an unbalanced consideration is unclear.


Asunto(s)
Pueblo Asiatico , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Grupos Minoritarios , Prevención Primaria/métodos , Sistema de Registros , Muerte Súbita Cardíaca/etnología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Reino Unido/epidemiología
5.
Heart ; 106(11): 793-801, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31949025

RESUMEN

Hypertrophic cardiomyopathy (HCM) is a common inherited cardiac condition, which typically manifests as left ventricular hypertrophy. A small subset of patients with HCM have an increased risk of sudden cardiac death (SCD) from ventricular arrhythmias. Risk of SCD can be effectively reduced following implantation of implantable cardiac defibrillators (ICD), although this treatment carries a risk of complications such as inappropriate shocks. With this in mind, we turn to advances in cardiac imaging to guide risk stratification for SCD and to select the appropriate individual who may benefit from ICD implantation. In this review, we have taken the opportunity to briefly summarise the role of imaging in the diagnosis of HCM before focusing on how specific imaging features influence risk of SCD in patients with HCM.


Asunto(s)
Cardiomiopatía Hipertrófica/complicaciones , Muerte Súbita Cardíaca/etiología , Medición de Riesgo/métodos , Cardiomiopatía Hipertrófica/mortalidad , Muerte Súbita Cardíaca/epidemiología , Salud Global , Humanos , Factores de Riesgo , Tasa de Supervivencia/tendencias
6.
Heart ; 106(7): 520-526, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31826936

RESUMEN

OBJECTIVE: In implantable cardiac defibrillators (ICDs), long-detection times safely reduce unnecessary and inappropriate therapies. We aimed to evaluate ICD treatment of ventricular arrhythmias in women, compared with men, also taking into account ICD detection. METHODS: The Advance III trial randomised patients implanted with an ICD for primary or secondary prevention in two arms-long and nominal ventricular arrhythmias detection times before therapy delivering (number of intervals needed to detect (NID) 30/40 and 18/24, respectively). The main endpoint of this post hoc analysis was the incidence of ICD therapies evaluated through Kaplan-Meier method and univariate Cox regression models. RESULTS: Overall, 1902 patients (304 women, 65±11 years) were randomised. Women showed a lower risk of ICD therapy (HR 0.63, 95% CI 0.43 to 0.93, p=0.022); this difference was observed only in the long-detection arm (HR 0.37, p=0.013) and not in the short detection arm (HR 0.82, p=0.414). No significant sex differences were observed concerning inappropriate therapies and mortality rate. Long-detection settings significantly reduced overall ICD therapies and appropriate ICD therapies, both in women (overall HR 0.31, p=0.007; appropriate HR 0.33, p=0.033) and in men (overall HR 0.69, p=0.006; appropriate HR 0.73, p=0.048). CONCLUSIONS: In patients with ICDs, the strategy of setting a long-detection time to treat ventricular arrhythmias (NID 30/40) reduces overall delivered therapies, both in women and men, when compared with nominal setting (NID 18/24). The reduction was significantly higher in women. Overall, women were less likely to experience ICD therapies than men; this result was only observed in the long-detection arm. CLINICAL TRIAL REGISTRATION: NCT00617175.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Anciano , Arritmias Cardíacas/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales , Método Simple Ciego , Factores de Tiempo
7.
Heart ; 106(14): 1052-1058, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32269130

RESUMEN

The systemic right ventricle (SRV), defined as the morphological right ventricle supporting the systemic circulation, is relatively common in congenital heart disease (CHD). Our review aimed at examining the current evidence, knowledge gaps and technical considerations regarding implantable cardiac electronic device therapy in patients with SRV. The risk of sinus node dysfunction (SND) after atrial switch repair and/or complete heart block in congenitally corrected transposition of great arteries requiring permanent pacing increases with age. Similar to acquired heart disease, indication for pacing includes symptomatic bradycardia, SND and high degree atrioventricular nodal block. Right ventricular dysfunction and heart failure also represent important complications in SRV patients. Cardiac resynchronisation therapy (CRT) has been proposed to improve systolic function in SRV patients, although indications for CRT are not well defined and its potential benefit remains uncertain. Amongst adult CHD, patients with SRV are at the highest risk for sudden cardiac death (SCD). Nevertheless, risk stratification for SCD is scarce in this cohort and implantable cardioverter-defibrillator indication is currently limited to secondary prevention. Vascular access and the incidence of device-related complications, such as infections, inappropriate shocks and device system failure, represent additional challenges to implantable cardiac electronic device therapy in patients with SRV. A multidisciplinary approach with tertiary expertise and future collaborative research are all paramount to further the care for this challenging nonetheless ever increasing cohort of patients.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica , Sistema de Conducción Cardíaco/fisiopatología , Cardiopatías Congénitas/cirugía , Frecuencia Cardíaca , Función Ventricular Derecha , Potenciales de Acción , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Procedimientos Quirúrgicos Cardíacos/mortalidad , Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/mortalidad , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/fisiopatología , Humanos , Marcapaso Artificial , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
8.
Heart ; 105(8): 623-631, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30366935

RESUMEN

OBJECTIVE: In 2014, the European Society of Cardiology (ESC) recommended the use of a novel risk prediction model (HCM Risk-SCD) to guide use of implantable cardioverter defibrillators (ICD) for the primary prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). We sought to determine the performance of HCM Risk-SCD by conducting a systematic review and meta-analysis of articles reporting on the prevalence of SCD within 5 years of evaluation in low, intermediate and high-risk patients as defined by the 2014 guidelines (predicted risk <4%, 4%-<6% and ≥6%, respectively). METHODS: The protocol was registered with PROSPERO (registration number: CRD42017064203). MEDLINE and manual searches for papers published from October 2014 to December 2017 were performed. Longitudinal, observational cohorts of unselected adult patients, without history of cardiac arrest were considered. The original HCM Risk-SCD development study was included a priori. Data were pooled using a random effects model. RESULTS: Six (0.9%) out of 653 independent publications identified by the initial search were included. The calculated 5-year risk of SCD was reported in 7291 individuals (70% low, 15% intermediate; 15% high risk) with 184 (2.5%) SCD endpoints within 5 years of baseline evaluation. Most SCD endpoints (68%) occurred in patients with an estimated 5-year risk of ≥4% who formed 30% of the total study cohort. Using the random effects method, the pooled prevalence of SCD endpoints was 1.01% (95% CI 0.52 to 1.61) in low-risk patients, 2.43% (95% CI 1.23 to 3.92) in intermediate and 8.4% (95% CI 6.68 to 10.25) in high-risk patients. CONCLUSIONS: This meta-analysis demonstrates that HCM Risk-SCD provides accurate risk estimations that can be used to guide ICD therapy in accordance with the 2014 ESC guidelines. REGISTRATION NUMBER: PROSPERO CRD42017064203;Pre-results.


Asunto(s)
Cardiomiopatía Hipertrófica , Muerte Súbita Cardíaca , Medición de Riesgo/métodos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/mortalidad , Exactitud de los Datos , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Europa (Continente) , Humanos , Guías de Práctica Clínica como Asunto , Prevención Primaria
9.
Heart ; 105(10): 775-782, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30381319

RESUMEN

BACKGROUND: Sexual dysfunction is common in patients with either ischaemic heart disease (IHD) or implantable cardioverter defibrillator (ICD) and has a negative impact on quality of life. Non-pharmacological treatment options are lacking. The purpose of this trial was to assess the effect of sexual rehabilitation versus usual care for males with erectile dysfunction and either IHD and/or ICD. METHODS: Participants with erectile dysfunction and IHD and/or ICD were randomised to 12 weeks of sexual rehabilitation consisting of physical exercise training, pelvic floor exercise and psychoeducation, or usual care. PRIMARY OUTCOME: sexual function by the International Index of Erectile Function (IIEF). Secondary outcome: sexual function by the Psychosocial Adjustment to Illness Scale. Exploratory outcomes: exercise capacity, pelvic floor strength/endurance, self-reported health and mental health. RESULTS: 154 participants were included, mean age 61.6 years (SD 6.1). Sexual rehabilitation compared with usual care improved sexual function with a mean difference IIEF score of 6.7 (95% CI 3.1 to 10.4, p<0.0003) at 4 months between groups (unadjusted IIEF mean scores 36.4 vs 31.3) and a mean difference of 6.7, 95% CI 3.2 to 10.1 (p<0.0002) at 6 months between groups (unadjusted mean scores IIEF 37.1 vs 32.2). No effects were seen on the secondary outcome. Sexual rehabilitation improved exercise capacity on cycle ergometer measured by Watt max with a mean difference of 10.3, 95% CI 3.6 to 16.9 (p<0.003) and pelvic floor strength (p<0.01). No differences were seen on self-reported health and mental health. CONCLUSION: Sexual rehabilitation compared with usual care improves sexual function and exercise capacity. TRIAL REGISTRATION: NCT01796353; Results.


Asunto(s)
Rehabilitación Cardiaca/métodos , Disfunción Eréctil/rehabilitación , Terapia por Ejercicio/métodos , Tolerancia al Ejercicio/fisiología , Salud Mental , Isquemia Miocárdica/rehabilitación , Conducta Sexual/fisiología , Disfunción Eréctil/etiología , Disfunción Eréctil/fisiopatología , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/fisiopatología , Calidad de Vida , Estudios Retrospectivos , Autoinforme
10.
Heart ; 105(2): 144-151, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30242141

RESUMEN

OBJECTIVES: Mitral valve prolapse (MVP) is commonly observed as a benign finding. However, the literature suggests that it may be associated with sudden cardiac death (SCD). We performed a meta-analysis and systematic review to determine the: (1) prevalence of MVP in the general population; (2) prevalence of MVP in all SCD and unexplained SCD; (3) incidence of SCD in MVP and (4) risk factors for SCD. METHODS: The English medical literature was searched for: (1) MVP community prevalence; (2) MVP prevalence in SCD cohorts; (3) incidence SCD in MVP and (4) SCD risk factors in MVP. Thirty-four studies were identified for inclusion. This study was registered with PROSPERO (CRD42018089502). RESULTS: The prevalence of MVP was 1.2% (95% CI 0.5 to 2.0) in community populations. Among SCD victims, the cause of death remained undetermined in 22.1% (95% CI 13.4 to 30.7); of these, MVP was observed in 11.7% (95% CI 5.8 to 19.1). The incidence of SCD in the MVP population was 0.14% (95% CI 0.1 to 0.3) per year. Potential risk factors for SCD include bileaflet prolapse, ventricular fibrosis complex ventricular ectopy and ST-T wave abnormalities. CONCLUSION: The high prevalence of MVP in cohorts of unexplained SCD despite low population prevalence provides indirect evidence of an association of MVP with SCD. The absolute number of people exposed to the risk of SCD is significant, although the incidence of life-threatening arrhythmic events in the general MVP population remains low. High-risk features include bileaflet prolapse, ventricular fibrosis, ST-T wave abnormalities and frequent complex ventricular ectopy. TRIAL REGISTRATION: PROSPERO (CRD42018089502).


Asunto(s)
Muerte Súbita Cardíaca/etiología , Ventrículos Cardíacos/diagnóstico por imagen , Prolapso de la Válvula Mitral/complicaciones , Muerte Súbita Cardíaca/epidemiología , Ecocardiografía , Salud Global , Ventrículos Cardíacos/fisiopatología , Humanos , Incidencia , Prolapso de la Válvula Mitral/diagnóstico , Prolapso de la Válvula Mitral/fisiopatología , Factores de Riesgo , Tasa de Supervivencia/tendencias
11.
Heart ; 105(4): 270-275, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30377260

RESUMEN

Sudden cardiac death (SCD) secondary to arrhythmia remains a risk in those with dilated cardiomyopathy (DCM), an implantable cardiac defibrillator (ICD) is an effective strategy to prevent SCD. Current guidelines recommend selection for ICD based on ejection fraction (EF) less than 35%, however, most SCD occurs in those with EF>35%. Although meta-analysis has demonstrated a survival benefit for primary prevention ICD in DCM, no randomised trial has shown a significant reduction in overall mortality including the most recent 'Danish Study to Assess the Efficacy of ICDs in Patients With Non-Ischemic Systolic Heat Failure on Mortality' study. Clearly, a more sophisticated selection strategy is required. Cardiac MRI (CMR) is an ideal non-invasive imaging technique which allows calculation of EF as well as tissue characterisation with gadolinium contrast, parametric mapping and feature tracking. Late gadolinium enhancement detects mid-wall fibrosis in approximately 30% of those with DCM, three meta-analyses have demonstrated an association between fibrosis in DCM and SCD, and those without fibrosis are at low risk of SCD. T1 mapping and extracellular volume (ECV) calculation are methods of demonstrating diffuse fibrosis in the myocardium. Raised ECV and native T1 have been associated with worse outcomes but the relationship to SCD has not been well studied. Undoubtedly, more research is required but CMR has several tools which offer incremental value above EF to improve risk stratification and consequent outcomes and resource utilisation in those with DCM.


Asunto(s)
Cardiomiopatía Dilatada , Muerte Súbita Cardíaca , Desfibriladores Implantables , Imagen por Resonancia Cinemagnética/métodos , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/terapia , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Humanos , Selección de Paciente , Medición de Riesgo/métodos
12.
Heart ; 104(2): 144-150, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28986406

RESUMEN

OBJECTIVE: The recent Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) trial suggested that implantable cardioverter defibrillators (ICDs) do not reduce overall mortality in patients with non-ischaemic cardiomyopathy (NICM), despite reducing sudden cardiac death. We performed an updated meta-analysis to examine the impact of ICD therapy on mortality in NICM patients. METHODS: A systematic search for studies that examined the effect of ICDs on outcomes in NICM was performed. Our analysis compared patients randomised to an ICD with those randomised to no ICD, and examined the endpoint of overall mortality. RESULTS: Six primary prevention trials and two secondary prevention trials were identified that met the pre-specified search criteria. Using a fixed-effects model, analysis of primary prevention trials revealed a reduction in overall mortality with ICD therapy (RR 0.76, 95% CI 0.65 to 0.91). CONCLUSIONS: Although our updated meta-analysis demonstrates a survival benefit of ICD therapy, the effect is substantively weakened by the inclusion of the DANISH trial-which is both the largest and most recent of the analysed trials-indicating that the residual pooled benefit of ICDs may reflect the risk of sudden death in older trials which included patients treated sub-optimally by contemporary standards. As such, these data must be interpreted cautiously. The results of the DANISH trial emphasise that there is no 'one size fits all' indication for primary prevention ICDs in NICM patients, and clinicians must consider age and comorbidity on an individual basis when determining whether a defibrillator is appropriate.


Asunto(s)
Cardiomiopatías , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Cardiomiopatías/etiología , Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Humanos , Prevención Primaria/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto
13.
Heart ; 104(18): 1529-1535, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29540431

RESUMEN

OBJECTIVE: In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection. METHODS: Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision. RESULTS: Acute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001). CONCLUSIONS: Compared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Prevención Primaria/métodos , Taquicardia Ventricular/prevención & control , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatía Dilatada/complicaciones , Femenino , Humanos , Masculino , Puntaje de Propensión , Factores de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
14.
Heart ; 104(6): 468-479, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29175975

RESUMEN

Lamins A and C are intermediate filament nuclear envelope proteins encoded by the LMNA gene. Mutations in LMNA cause autosomal dominant severe heart disease, accounting for 10% of dilated cardiomyopathy (DCM). Characterised by progressive conduction system disease, arrhythmia and systolic impairment, lamin A/C heart disease is more malignant than other common DCMs due to high event rates even when the left ventricular impairment is mild. It has several phenotypic mimics, but overall it is likely to be an under-recognised cause of DCM. In certain clinical scenarios, particularly familial DCM with early conduction disease, the pretest probability of finding an LMNA mutation may be quite high.Recognising lamin A/C heart disease is important because implantable cardioverter defibrillators need to be implanted early. Promising oral drug therapies are within reach thanks to research into the mitogen-activated protein kinase (MAPK) and affiliated pathways. Personalised heart failure therapy may soon become feasible for LMNA, alongside personalised risk stratification, as variant-related differences in phenotype severity and clinical course are being steadily elucidated.Genotyping and family screening are clinically important both to confirm and to exclude LMNA mutations, but it is the three-pronged integration of such genetic information with functional data from in vivo cardiomyocyte mechanics, and pathological data from microscopy of the nuclear envelope, that is properly reshaping our LMNA knowledge base, one variant at a time. This review explains the biology of lamin A/C heart disease (genetics, structure and function of lamins), clinical presentation (diagnostic pointers, electrocardiographic and imaging features), aspects of screening and management, including current uncertainties, and future directions.


Asunto(s)
Cardiomiopatía Dilatada , Lamina Tipo A/genética , Técnicas de Imagen Cardíaca , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/terapia , Manejo de la Enfermedad , Humanos , Mutación
15.
Heart ; 103(17): 1315-1322, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28687562

RESUMEN

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are considered an alternative to conventional transvenous ICDs (TV-ICDs) in patients not requiring pacing. METHODS: We searched MEDLINE and EMBASE for studies evaluating efficacy and safety outcomes in S-ICD patients. Outcomes were pooled across studies. RESULTS: Sixteen studies were included with 5380 participants (mean age range 33-56 years). Short-term follow-up data were available for 1670 subjects. The most common complication was pocket infection, affecting 2.7%. Other complications included delayed wound healing (0.6%) and wound discomfort (0.8%). 3.8% of S-ICDs were explanted, most commonly for pocket infection. Mortality rates in hospital (0.4%) and during follow-up (3.4% from 12 studies reporting) were low. Incidence of ventricular arrhythmia varied from 0% to 12%. Overall shock efficacy exceeded 96%. Inappropriate shocks affected 4.3% and was most commonly caused by T-wave oversensing. CONCLUSIONS: Although long-term randomised data are lacking, observational data suggest similar shock efficacy and short-term complication rates between the S-ICD and TV-ICD.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Diseño de Equipo , Humanos
16.
Forensic Sci Int ; 275: 14-22, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28288337

RESUMEN

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a primary cardiomyopathy characterised by fibrofatty replacement and ventricular arrhythmias. The occurrence of malignant arrhythmias may be associated with fatty infiltration and intercalated disk remodelling, but the specific pathological remodelling pattern is not yet clear. METHODS: Twelve explanted hearts from patients diagnosed with ARVC/D according to the 2010 Task Force Criteria and pathology examination were divided into two groups with (SVT, n=6) or without (non-SVT, n=6) recurrent sustained ventricular tachycardia (SVT) before heart transplantation. Six ARVC autopsy hearts and six normal donor hearts were also collected. We evaluated the fibrofatty infiltration by Masson staining and the expression of intercalated disc proteins through immunohistochemistry staining combined with western blot using the ventricular tissue of ARVC as well as normal hearts. RESULTS: There was significant fatty replacement in the right ventricles of both the SVT and the non-SVT groups compared to normal hearts, but no significant differences were found in fibre, fatty and residual myocardium components between these two groups. Immunohistochemistry and western blot further showed disturbed distribution and significantly reduced expression of Connexin 43 (Cx43) in the SVT group (SVT vs. Normal P=0.010, SVT vs. non-SVT P=0.012). No significantly diminished expression was found in the non-SVT group. The cardiac histology of ARVC/D patients with sudden death verified by forensic pathology confirmed a similar phenomenon. CONCLUSION: Our pathology study on explanted and autopsied hearts indicates that the expression of Cx43 was significantly reduced and disturbed in distribution in ARVC/D myocardium with sustained ventricular tachycardia, but not in patients without malignant ventricular arrhythmias. This implies a correlation between Cx43 remodelling and malignant arrhythmias in ARVC/D patients.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/metabolismo , Conexina 43/metabolismo , Miocardio/metabolismo , Taquicardia Ventricular/metabolismo , Adulto , Displasia Ventricular Derecha Arritmogénica/patología , Western Blotting , Estudios de Casos y Controles , Muerte Súbita Cardíaca , Susceptibilidad a Enfermedades , Femenino , Ventrículos Cardíacos/patología , Humanos , Inmunohistoquímica , Masculino , Miocardio/patología
17.
Bioengineering (Basel) ; 4(1)2017 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-28952498

RESUMEN

Thisstudy aims to compute 50 Hz electric field interferences on pacemakers for diverse lead configurations and implantation positions. Induced phenomena in a surface-based virtual human model (standing male grounded with arms closed, 2 mm resolution) are computed for vertical exposure using CST EM® 3D software, with and without an implanted pacemaker. Induced interference voltages occurring on the pacemaker during exposure are computed and the results are discussed. The bipolar mode covers 99% of the implanted pacing leads in the USA and Europe, according to statistics. The tip-to-ring distance of a lead may influence up to 46% of the induced voltage. In bipolar sensing mode, right ventricle implantation has a 41% higher induced voltage than right atrium implantation. The induced voltage is in average 10 times greater in unipolar mode than in bipolar mode, when implanted in the right atrium or right ventricle. The electric field threshold of interference for a bipolar sensing mode in the worst case setting is 7.24 kV·m-1, and 10 times higher for nominal settings. These calculations will be completed by an in vitro study.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda