Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 10.849
Filtrar
Más filtros

Publication year range
1.
Annu Rev Med ; 75: 263-276, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37827195

RESUMEN

Interventional pulmonary medicine has developed as a subspecialty focused on the management of patients with complex thoracic disease. Leveraging minimally invasive techniques, interventional pulmonologists diagnose and treat pathologies that previously required more invasive options such as surgery. By mitigating procedural risk, interventional pulmonologists have extended the reach of care to a wider pool of vulnerable patients who require therapy. Endoscopic innovations, including endobronchial ultrasound and robotic and electromagnetic bronchoscopy, have enhanced the ability to perform diagnostic procedures on an ambulatory basis. Therapeutic procedures for patients with symptomatic airway disease, pleural disease, and severe emphysema have provided the ability to palliate symptoms. The combination of medical and procedural expertise has made interventional pulmonologists an integral part of comprehensive care teams for patients with oncologic, airway, and pleural needs. This review surveys key areas in which interventional pulmonologists have impacted the care of thoracic disease through bronchoscopic intervention.


Asunto(s)
Neumología , Enfermedades Torácicas , Humanos , Neumología/métodos , Broncoscopía/métodos
2.
Circulation ; 149(12): e986-e995, 2024 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-38375663

RESUMEN

Representation of women in interventional vascular fields (interventional cardiology, interventional radiology, and vascular surgery) lags behind that in other specialties. With women representing half of all medical school graduates, encouraging parity of women in these fields needs to start in medical school. Barriers to pursuing careers in vascular intervention include insufficient exposure during core clerkships, early mentorship, visibility of women in the field, length of training, lifestyle considerations, work culture and environment, and concerns about radiation exposure. This scientific statement highlights potential solutions for both the real and perceived barriers that women may face in pursuing careers in vascular intervention, including streamlining of training (as both interventional radiology and vascular surgery have done with a resultant increase in percentage of women trainees), standardization of institutional promotion of women in leadership, and professional and industry partnerships for the retention and advancement of women.


Asunto(s)
American Heart Association , Procedimientos Quirúrgicos Vasculares , Estados Unidos , Humanos , Femenino
3.
Biostatistics ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38576206

RESUMEN

Mediation analysis is appealing for its ability to improve understanding of the mechanistic drivers of causal effects, but real-world data complexities challenge its successful implementation, including (i) the existence of post-exposure variables that also affect mediators and outcomes (thus, confounding the mediator-outcome relationship), that may also be (ii) multivariate, and (iii) the existence of multivariate mediators. All three challenges are present in the mediation analysis we consider here, where our goal is to estimate the indirect effects of receiving a Section 8 housing voucher as a young child on the risk of developing a psychiatric mood disorder in adolescence that operate through mediators related to neighborhood poverty, the school environment, and instability of the neighborhood and school environments, considered together and separately. Interventional direct and indirect effects (IDE/IIE) accommodate post-exposure variables that confound the mediator-outcome relationship, but currently, no readily implementable nonparametric estimator for IDE/IIE exists that allows for both multivariate mediators and multivariate post-exposure intermediate confounders. The absence of such an IDE/IIE estimator that can easily accommodate both multivariate mediators and post-exposure confounders represents a significant limitation for real-world analyses, because when considering each mediator subgroup separately, the remaining mediator subgroups (or a subset of them) become post-exposure intermediate confounders. We address this gap by extending a recently developed nonparametric estimator for the IDE/IIE to allow for easy incorporation of multivariate mediators and multivariate post-exposure confounders simultaneously. We apply the proposed estimation approach to our analysis, including walking through a strategy to account for other, possibly co-occurring intermediate variables when considering each mediator subgroup separately.

4.
Eur Heart J ; 45(31): 2839-2847, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38966936

RESUMEN

BACKGROUND AND AIMS: Drug-coated balloons (DCBs) have demonstrated favourable outcomes following endovascular therapy for femoropopliteal artery (FPA) disease. However, uncertainty remains whether the use of intravascular ultrasound (IVUS) can improve the outcomes of DCBs. METHODS: This prospective, multicentre, randomized trial, conducted at seven centres in South Korea, compared the outcomes of IVUS-guided vs. angiography-guided angioplasty for treating FPA disease with DCBs. Patients were assigned to receive IVUS-guided (n = 119) or angiography-guided (n = 118) angioplasty using DCBs. The primary endpoint was 12-month primary patency. RESULTS: Between May 2016 and August 2022, 237 patients were enrolled and 204 (86.0%) completed the trial (median follow-up; 363 days). The IVUS guidance group showed significantly higher primary patency [83.8% vs. 70.1%; cumulative difference 19.6% (95% confidence interval 6.8 to 32.3); P = .01] and increased freedom from clinically driven target lesion revascularization [92.4% vs. 83.0%; difference 11.6% (95% confidence interval 3.1 to 20.1); P = .02], sustained clinical improvement (89.1% vs. 76.3%, P = .01), and haemodynamic improvement (82.4% vs. 66.9%, P = .01) at 12 months compared with the angiography guidance group. The IVUS group utilized larger balloon diameters and pressures for pre-dilation, more frequent post-dilation, and higher pressures for post-dilation, resulting in a greater post-procedural minimum lumen diameter (3.90 ± 0.59 vs. 3.71 ± 0.73 mm, P = .03). CONCLUSIONS: Intravascular ultrasound guidance significantly improved the outcomes of DCBs for FPA disease in terms of primary patency, freedom from clinically driven target lesion revascularization, and sustained clinical and haemodynamic improvement at 12 months. These benefits may be attributed to IVUS-guided optimization of the lesion before and after DCB treatment.


Asunto(s)
Angioplastia de Balón , Arteria Femoral , Enfermedad Arterial Periférica , Arteria Poplítea , Ultrasonografía Intervencional , Grado de Desobstrucción Vascular , Humanos , Ultrasonografía Intervencional/métodos , Masculino , Angioplastia de Balón/métodos , Arteria Femoral/diagnóstico por imagen , Femenino , Arteria Poplítea/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/diagnóstico por imagen , Estudios Prospectivos , Anciano , Persona de Mediana Edad , Materiales Biocompatibles Revestidos , Resultado del Tratamiento , Angiografía
5.
Gut ; 73(5): 787-796, 2024 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-38267201

RESUMEN

OBJECTIVE: To describe the long-term consequences of necrotising pancreatitis, including complications, the need for interventions and the quality of life. DESIGN: Long-term follow-up of a prospective multicentre cohort of 373 necrotising pancreatitis patients (2005-2008) was performed. Patients were prospectively evaluated and received questionnaires. Readmissions (ie, for recurrent or chronic pancreatitis), interventions, pancreatic insufficiency and quality of life were compared between initial treatment groups: conservative, endoscopic/percutaneous drainage alone and necrosectomy. Associations of patient and disease characteristics during index admission with outcomes during follow-up were assessed. RESULTS: During a median follow-up of 13.5 years (range 12-15.5 years), 97/373 patients (26%) were readmitted for recurrent pancreatitis. Endoscopic or percutaneous drainage was performed in 47/373 patients (13%), of whom 21/47 patients (45%) were initially treated conservatively. Pancreatic necrosectomy or pancreatic surgery was performed in 31/373 patients (8%), without differences between treatment groups. Endocrine insufficiency (126/373 patients; 34%) and exocrine insufficiency (90/373 patients; 38%), developed less often following conservative treatment (p<0.001 and p=0.016, respectively). Quality of life scores did not differ between groups. Pancreatic gland necrosis >50% during initial admission was associated with percutaneous/endoscopic drainage (OR 4.3 (95% CI 1.5 to 12.2)), pancreatic surgery (OR 3.2 (95% CI 1.1 to 9.5) and development of endocrine insufficiency (OR13.1 (95% CI 5.3 to 32.0) and exocrine insufficiency (OR6.1 (95% CI 2.4 to 15.5) during follow-up. CONCLUSION: Acute necrotising pancreatitis carries a substantial disease burden during long-term follow-up in terms of recurrent disease, the necessity for interventions and development of pancreatic insufficiency, even when treated conservatively during the index admission. Extensive (>50%) pancreatic parenchymal necrosis seems to be an important predictor of interventions and complications during follow-up.


Asunto(s)
Insuficiencia Pancreática Exocrina , Pancreatitis Aguda Necrotizante , Pancreatitis Crónica , Humanos , Pancreatitis Aguda Necrotizante/complicaciones , Pancreatitis Aguda Necrotizante/cirugía , Estudios de Seguimiento , Calidad de Vida , Estudios Prospectivos , Insuficiencia Pancreática Exocrina/etiología , Pancreatitis Crónica/complicaciones , Drenaje/efectos adversos , Necrosis , Resultado del Tratamiento
6.
Circulation ; 148(16): 1195-1206, 2023 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-37634092

RESUMEN

BACKGROUND: Intravascular imaging-guided percutaneous coronary intervention (PCI) with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) showed superior clinical outcomes compared with angiography-guided PCI. However, the comparative effectiveness of OCT-guided and IVUS-guided PCI regarding clinical outcomes is unknown. METHODS: In this prospective, multicenter, open-label, pragmatic trial, we randomly assigned 2008 patients with significant coronary artery lesions undergoing PCI in a 1:1 ratio to undergo either an OCT-guided or IVUS-guided PCI. The primary end point was a composite of death from cardiac causes, target vessel-related myocardial infarction, or ischemia-driven target-vessel revascularization at 1 year, which was powered for noninferiority of the OCT group compared with the IVUS group. Safety outcomes were also assessed. RESULTS: At 1 year, primary end point events occurred in 25 of 1005 patients (Kaplan-Meier estimate, 2.5%) in the OCT group and in 31 of 1003 patients (Kaplan-Meier estimate, 3.1%) in the IVUS group (absolute difference, -0.6 percentage points; upper boundary of one-sided 97.5% CI, 0.97 percentage points; P<0.001 for noninferiority). The incidence of contrast-induced nephropathy was similar (14 patients [1.4%] in the OCT group versus 15 patients [1.5%] in the IVUS group; P=0.85). The incidence of major procedural complications was lower in the OCT group than in the IVUS group (22 [2.2%] versus 37 [3.7%]; P=0.047), although imaging procedure-related complications were not observed. CONCLUSIONS: In patients with significant coronary artery lesions, OCT-guided PCI was noninferior to IVUS-guided PCI with respect to the incidence of a composite of death from cardiac causes, target vessel-related myocardial infarction, or ischemia-driven target-vessel revascularization at 1 year. The selected study population and lower-than-expected event rates should be considered in interpreting the trial. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique number: NCT03394079.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria/métodos , Tomografía de Coherencia Óptica/métodos , Estudios Prospectivos , Stents Liberadores de Fármacos/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Ultrasonografía Intervencional/métodos , Resultado del Tratamiento , Infarto del Miocardio/etiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
7.
Am J Epidemiol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123099

RESUMEN

Placental abruption, the premature placental separation, confers increased perinatal mortality risk with preterm delivery as an important pathway through which the risk appears mediated. While pregnancies complicated by abruption are often delivered through an obstetrical intervention, many deliver spontaneously. We examined the contributions of clinician-initiated (PTDIND) and spontaneous (PTDSPT) preterm delivery at <37 weeks as competing causal mediators of the abruption-perinatal mortality association. Using the Consortium for Safe Labor (2002-2008) data (n = 203,990; 1.6% with abruption), we applied a potential outcomes-based mediation analysis to decompose the total effect into direct and mediator-specific indirect effects through PTDIND and PTDSPT. Each mediated effect describes the reduction in the counterfactual mortality risk if that preterm delivery subtype was shifted from its distribution under abruption to without abruption. The total effect risk ratio (RR) of abruption on perinatal mortality was 5.4 (95% confidence interval [CI] 4.6, 6.3). The indirect effect RRs for PTDIND and PTDSPT were 1.5 (95% CI: 1.4, 1.6) and 1.5 (95% CI: 1.5, 1.6), respectively; these corresponded to mediated proportions of 25% each. These findings underscore that spontaneous and clinician-initiated preterm deliveries each play essential roles in shaping perinatal mortality risks associated with placental abruption.

8.
Cancer ; 130(15): 2703-2712, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38642369

RESUMEN

PURPOSE: To evaluate outcomes following percutaneous image-guided ablation of soft tissue sarcoma metastases to the liver. MATERIALS AND METHODS: A single-institution retrospective analysis of patients with a diagnosis of metastatic soft tissue sarcoma who underwent percutaneous image-guided ablation of hepatic metastases between January 2011 and December 2021 was performed. Patients with less than 60 days of follow-up after ablation were excluded. The primary outcome was local tumor progression-free survival (LPFS). Secondary outcomes included overall survival, liver-specific progression-free survival. and chemotherapy-free survival. RESULTS: Fifty-five patients who underwent percutaneous ablation for 84 metastatic liver lesions were included. The most common histopathological subtypes were leiomyosarcoma (23/55), followed by gastrointestinal stromal tumor (22/55). The median treated liver lesions was 2 (range, 1-8), whereas the median size of metastases were 1.8 cm (0.3-8.7 cm). Complete response at 2 months was achieved in 90.5% of the treated lesions. LPFS was 83% at 1 year and 80% at 2 years. Liver-specific progression-free survival was 66% at 1 year and 40% at 2 years. The overall survival at 1 and 2 years was 98% and 94%. The chemotherapy-free holiday from the start of ablation was 71.2% at 12 months. The complication rate was 3.6% (2/55); one of the complications was Common Terminology Criteria for Adverse Events grade 3 or higher. LPFS subgroup analysis for leiomyosarcoma versus gastrointestinal stromal tumor suggests histology-agnostic outcomes (2 years, 89% vs 82%, p = .35). CONCLUSION: Percutaneous image-guided liver ablation of soft tissue sarcoma metastases is safe and efficacious.


Asunto(s)
Neoplasias Hepáticas , Sarcoma , Humanos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Femenino , Masculino , Persona de Mediana Edad , Sarcoma/cirugía , Sarcoma/patología , Sarcoma/secundario , Sarcoma/mortalidad , Anciano , Estudios Retrospectivos , Adulto , Anciano de 80 o más Años , Leiomiosarcoma/cirugía , Leiomiosarcoma/patología , Leiomiosarcoma/secundario , Leiomiosarcoma/mortalidad , Resultado del Tratamiento , Supervivencia sin Progresión , Tumores del Estroma Gastrointestinal/cirugía , Tumores del Estroma Gastrointestinal/patología , Tumores del Estroma Gastrointestinal/mortalidad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos
9.
Biostatistics ; 24(3): 686-707, 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-35102366

RESUMEN

Causal mediation analysis has historically been limited in two important ways: (i) a focus has traditionally been placed on binary exposures and static interventions and (ii) direct and indirect effect decompositions have been pursued that are only identifiable in the absence of intermediate confounders affected by exposure. We present a theoretical study of an (in)direct effect decomposition of the population intervention effect, defined by stochastic interventions jointly applied to the exposure and mediators. In contrast to existing proposals, our causal effects can be evaluated regardless of whether an exposure is categorical or continuous and remain well-defined even in the presence of intermediate confounders affected by exposure. Our (in)direct effects are identifiable without a restrictive assumption on cross-world counterfactual independencies, allowing for substantive conclusions drawn from them to be validated in randomized controlled trials. Beyond the novel effects introduced, we provide a careful study of nonparametric efficiency theory relevant for the construction of flexible, multiply robust estimators of our (in)direct effects, while avoiding undue restrictions induced by assuming parametric models of nuisance parameter functionals. To complement our nonparametric estimation strategy, we introduce inferential techniques for constructing confidence intervals and hypothesis tests, and discuss open-source software, the $\texttt{medshift}$$\texttt{R}$ package, implementing the proposed methodology. Application of our (in)direct effects and their nonparametric estimators is illustrated using data from a comparative effectiveness trial examining the direct and indirect effects of pharmacological therapeutics on relapse to opioid use disorder.


Asunto(s)
Análisis de Mediación , Modelos Estadísticos , Humanos , Modelos Teóricos , Causalidad
10.
Small ; : e2404251, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39175372

RESUMEN

Peripheral vascular interventions (PVIs) offer several benefits to patients with lower extremity arterial diseases, including reduced pain, simpler anesthesia, and shorter recovery time, compared to open surgery. However, to monitor the endovascular tools inside the body, PVIs are conducted under X-ray fluoroscopy, which poses serious long-term health risks to physicians and patients. Shortwave infrared (SWIR) imaging of quantum dots (QDs) has shown great potential in bioimaging due to the non-ionizing penetration of SWIR light through tissues. In this paper, a QD-based magnetic guidewire and its system is introduced that allows X-ray-free detection under SWIR imaging and precise steering via magnetic manipulation. The QD magnetic guidewire contains a flexible silicone tube encapsulating a QD polydimethylsiloxane (PDMS) composite, where HgCdSe/HgS/CdS/CdZnS/ZnS/SiO2 core/multi-shell QDs are dispersed in the PDMS matrix for SWIR imaging upon near-infrared excitation, as well as a permanent magnet for magnetic steering. The SWIR penetration of the QD magnetic guidewire is investigated within an artificial tissue model (1% Intralipid) and explore the potential for non-fluoroscopic PVIs within a vascular phantom model. The QD magnetic guidewire is biocompatible in its entirety, with excellent resistance to photobleaching and chemical alteration, which is a promising sign for its future clinical implementation.

11.
Magn Reson Med ; 91(1): 266-279, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37799087

RESUMEN

PURPOSE: Interactive cardiac MRI is used for fast scan planning and MR-guided interventions. However, the requirement for real-time acquisition and near-real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework-HyperSLICE- was compared with conventional Cartesian real-time and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post hoc Nemenyi test (p < 0.05). RESULTS: In simulations the normalized RMS error, peak SNR, structural similarity, and Laplacian energy were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (structural similarity: 0.71 vs. 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back, showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared with radial and uniform spiral trajectories.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Estudios Prospectivos , Imagen por Resonancia Magnética , Contencion de la Respiración
12.
Magn Reson Med ; 92(1): 346-360, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38394163

RESUMEN

PURPOSE: To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION: Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.


Asunto(s)
Diseño de Equipo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Animales , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Artefactos , Imagen por Resonancia Magnética Intervencional/instrumentación
13.
Artículo en Inglés | MEDLINE | ID: mdl-38552324

RESUMEN

OBJECTIVE: We hypothesized that glucocorticoids would induce remission in very early Systemic Sclerosis patients by inhibition of inflammation driving the disease. We examined the efficacy and safety of methylprednisolone in very early Systemic Sclerosis. METHODS: In this trial adults with puffy fingers for less than three years, specific auto-antibodies and meeting the Very Early Diagnosis of Systemic Sclerosis criteria were randomly assigned (2:1) to methylprednisolone 1000 mg intravenously or placebo for 3 consecutive days 3 times with monthly intervals. The primary end point was nailfold capillary density at week 12. Capillary density at 52 weeks, number of megacapillaries, and patient-reported outcomes were secondary outcomes. In addition, we assessed disease progression and lung function decline over 52 weeks. We used linear regression analyses adjusted for baseline values and stratification variables to estimate differences between groups. RESULTS: Between February 2017 and February 2021, 87 patients were screened, of whom 30 (70% female, median (IQR) age 52·9 (40·8-60·8) years, median (IQR) disease duration 11.4 (4.6-18.6) months) were randomly assigned to methylprednisolone (n = 21) or placebo (n = 9). We found no difference in nailfold capillary density at 12 weeks: -0.5 (95% CI 1.1, 0.2) nor in any of the secondary outcomes. Eleven (37%) patients showed disease progression during 1 year follow up, 7 (23%) patients had a relevant pulmonary function decline. No serious adverse events were reported. CONCLUSIONS: No clinically relevant effect of short-term methylprednisolone in patients with very early Systemic Sclerosis was observed. A substantial proportion of patients showed disease progression.

14.
J Cardiovasc Electrophysiol ; 35(2): 258-266, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38065834

RESUMEN

BACKGROUND: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA). AIM: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue. METHODS: Ten patients (63.1 ± 5.7 years old, 80% male) receiving a RFCA for paroxysmal AF underwent a CMR before (<1 week) and after (<1 h) the PVAI. Two-dimensional dark-blood T2-weighted short tau inversion recovery (DB-STIR), Three-dimensional inversion-recovery prepared long inversion time (3D-TWILITE) and three-dimensional late gadolinium enhancement (3D-LGE) images were performed to visualize PVAI-L. RESULTS: The PVAI-L was visible in 10 patients (100%) using 3D-TWILITE and 3D-LGE. Conversely, On DB-STIR, the ablation core of the PAVI-L could not be identified because of a diffuse high signal of the atrial wall post-PVAI. Microvascular obstruction was identified in 7 (70%) patients using 3D-LGE. CONCLUSION: CMR can visualize PVAI-L immediately after the RFCA of AF even without the use of contrast agents. Future studies are needed to understand if the use of CMR for PVAI-L detection after RFCA can improve the results of ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Resultado del Tratamiento , Gadolinio , Espectroscopía de Resonancia Magnética , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
15.
Rev Endocr Metab Disord ; 25(1): 161-173, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37946091

RESUMEN

Ultrasound (US) of the thyroid has been used as a diagnostic tool since the late 1960s. US is the most important imaging tool for diagnosing thyroid disease. In the majority of cases a correct diagnosis can already be made in synopsis of the sonographic together with clinical findings and basal thyroid hormone parameters. However, the characterization of thyroid nodules by US remains challenging. The introduction of Thyroid Imaging Reporting and Data Systems (TIRADSs) has improved diagnostic accuracy of thyroid cancer significantly. Newer techniques such as elastography, superb microvascular imaging (SMI), contrast enhanced ultrasound (CEUS) and multiparametric ultrasound (MPUS) expand diagnostic options and tools further. In addition, the use of artificial intelligence (AI) is a promising tool to improve and simplify diagnostics of thyroid nodules and there is evidence that AI can exceed the performance of humans. Combining different US techniques with the introduction of new software, the use of AI, FNB as well as molecular markers might pave the way for a completely new area of diagnostic accuracy in thyroid disease. Finally, interventional ultrasound using US-guided thermal ablation (TA) procedures are increasingly proposed as therapy options for benign as well as malignant thyroid diseases.


Asunto(s)
Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Inteligencia Artificial , Diagnóstico Diferencial
16.
BMC Cancer ; 24(1): 387, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38539150

RESUMEN

BACKGROUND: The safety and efficacy of transarterial chemoembolization plus molecular targeted therapy (MTT) combined with immune checkpoint inhibitors (ICIs) in primary liver cancer have been demonstrated. However, the evidence for TACE plus MTT combined with ICIs in the treatment of recurrent hepatocellular carcinoma (RHCC) is limited. Given the excellent performance of this combination regimen in primary liver cancer, it is necessary to evaluate the efficacy of TACE plus MTT combined with ICIs in RHCC. METHODS: A total of 88 patients with RHCC treated with TACE plus MTT combined with camrelizumab (TACE-TC group, n = 46) or TACE plus MTT (TACE-T group, n = 42) were retrospectively collected and analyzed. In this study, we evaluated the effectiveness and safety of combination therapy for patients with RHCC by analyzing tumor response, progression-free survival (PFS), overall survival (OS), laboratory biochemical indices, and adverse events (AEs). RESULTS: TACE-TC was superior to TACE-T in PFS (14.0 vs. 8.9 months, p = 0.034) and OS (31.1 vs. 20.2 months, p = 0.009). Moreover, TACE-TC achieved more preferable benefits with respect to disease control rate (89.1% vs. 71.4%, p = 0.036) and objective response rate (47.8% vs. 26.2%, p = 0.036) compared with TACE-T in patients with RHCC. Compared with the TACE-T group, the AFP level in the TACE-TC group decreased more significantly after 3 months of treatment. Multivariate analysis showed that treatment option was a significant predictor of OS and PFS, while the portal vein tumor thrombus and interval of recurrence from initial treatment were another prognostic factor of PFS. There was no significant difference between the TACE-TC and TACE-T groups for Grade 3-4 adverse events. CONCLUSIONS: A combination therapy of TACE, MTT, and camrelizumab significantly improved tumor response and prolonged survival duration, showing a better survival prognosis for RHCC patients.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/tratamiento farmacológico , Terapia Molecular Dirigida , Estudios Retrospectivos , Quimioembolización Terapéutica/efectos adversos
17.
Ann Hematol ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39174754

RESUMEN

Since the late 1980s, patient registries have played a pivotal role in the elucidation of rare diseases. For myelodysplastic syndromes (MDS), they revealed the disease actually to be diverse rather than rare. Registry data enabled the definition of various MDS subtypes and prognostic scores tailoring therapy. These classifications have been revised and refined several times, and the differential diagnosis of MDS has become increasingly complex. At the same time, the diagnosis has been made more commonly and no longer by specialized centers of expertise only. Consequently, several registries have collected data with different focuses and from different patient subpopulations. The current review presents three MDS registries and their rationale, scope, design, and achievements. All three complement each other and will remain a mainstay to advance the knowledge on MDS as well as to validate the outcomes of clinical trials. However, delineation of subtypes after the most recent WHO and IPC revisions, as well as the determination of the newest risk score M of the International Prognostic Scoring System (IPSS-M), no longer just shift cut-offs but are based on multivariate compilations of highly specific genetic information. This paradigm shift involves challenging registries with respect to the assignment of all patients for whom this information has not yet been available.

18.
Catheter Cardiovasc Interv ; 103(2): 295-307, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091341

RESUMEN

Management of intracoronary calcium (ICC) continues to be a challenge for interventional cardiologists. There have been significant advances in calcium treatment devices. However, there still exists a knowledge gap regarding which devices to choose for the treatment of ICC. The purpose of this manuscript is to review the principles of intravascular lithotripsy (IVL) and clinical data. The technique of IVL will then be compared to alternative calcium treatment devices. Clinical data will be reviewed concerning the treatment of coronary, peripheral artery and valvular calcifications. Controversies to be discussed include how to incorporate IVL into your practice, what is the best approach for treating calcium subtypes, how to approach under-expanded stents, what is the ideal technique for performing IVL, how safe is IVL, whether imaging adds value when performing IVL, and how IVL fits into a treatment program for peripheral arteries and calcified valves.


Asunto(s)
Cardiólogos , Litotricia , Calcificación Vascular , Humanos , Calcio , Resultado del Tratamiento , Vasos Coronarios , Litotricia/efectos adversos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia
19.
Catheter Cardiovasc Interv ; 104(2): 401-407, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38819910

RESUMEN

BACKGROUND: Most patients undergoing the mitral transcatheter edge-to-edge repair (TEER) technique are elderly comorbid patients. Low body mass index (BMI) < 23 kg/m2 has been identified in other elderly populations as a risk factor, but has not been studied sufficiently in mitral TEER. AIMS: We aimed to study the impact of low BMI (23 kg/m2) on the outcome after mitral TEER. METHODS: Patients undergoing first-time TEER for mitral regurgitation at a single tertiary center were included, with the exclusion of patients with preprocedural hemodynamic instability or missing BMI. The primary endpoint was all-cause mortality. Secondary endpoints were long-term major bleeding or admission with heart failure. RESULTS: A total of 120 patients (mean age 76 ± 10 years, 76% men) were included in the study. Thirty-nine (31%) had low BMI. Patients with low BMI had a similar symptomatic benefit as patients with BMI ≥ 23 kg/m2 at 1 year regarding decrease in diuretics dose and decrease in New York Heart Association (NYHA) class (p > 0.05). In a multivariable Cox regression analysis, BMI as a continuous variable (hazard ratio [HR]: 0.93 [95% confidence interval, CI: 0.87-0.99], p = 0.03) and low BMI (HR: 1.99 [95% CI: 1.12-3.52], p = 0.02) were associated with the primary outcome. Low BMI was not significantly associated with major bleeding (subdistribution hazard ratio [SHR]: 2.39 [95% CI: 0.96-5.97], p = 0.06) or admission with heart failure (SHR: 1.06 [95% CI: 0.61-1.88], p = 0.83) during follow-up with univariable competing risk regression analysis. CONCLUSION: Low BMI is a risk factor for mortality after mitral valve TEER, confirming the presence of an "obesity paradox" in this population and should receive attention in patient selection.


Asunto(s)
Índice de Masa Corporal , Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Femenino , Masculino , Factores de Riesgo , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Factores de Tiempo , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Delgadez/mortalidad , Delgadez/diagnóstico , Delgadez/fisiopatología , Delgadez/complicaciones , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemorragia/mortalidad , Obesidad/mortalidad , Obesidad/diagnóstico , Obesidad/complicaciones , Obesidad/fisiopatología
20.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38713867

RESUMEN

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Asunto(s)
Presión Sanguínea , Aprobación de Recursos , Hipertensión , Arteria Renal , Simpatectomía , United States Food and Drug Administration , Humanos , Estados Unidos , Simpatectomía/efectos adversos , Simpatectomía/instrumentación , Hipertensión/fisiopatología , Hipertensión/cirugía , Arteria Renal/inervación , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento , Riñón/irrigación sanguínea , Comités Consultivos , Diseño de Equipo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda