Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 320
Filtrar
1.
Odontology ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38634968

RESUMEN

The purpose of this study was to investigate the vertical marginal discrepancy (VMD) and residual excess cement (REC) of cementable and screwmentable monolithic zirconia crowns cemented with different types of cement. Abutments were attached to 40 implant analogues. Crowns were created using computer-aided design/computer-aided manufacturing technology from monolithic zirconia blocks, either with or without a screw access hole (SAC). Crowns created both ways were split into two groups and cemented with resin and zinc polycarboxylate cement under a 5-kg weight. VMD and REC values were evaluated using an X20 zoom stereomicroscope. Data were analysed using two-way ANOVA and the Bonferroni test. According to the two-way ANOVA results, REC measurements differed significantly in the crown design and cement groups. However, whilst VMD values were significantly different in both crown design groups, there was no significant difference in the cement groups. According to the Bonferroni test results, the highest REC (157.241 ± 44.29 µm) and VMD (68.052 ± 16.19 µm) values were found in the crowns without SAC and cemented with zinc polycarboxylate. Screwmentable crowns are more effective than cementable crowns in reducing REC and VMD. Whilst polycarboxylate cement reduces VMD in screwmentable crowns, resin cement is more suitable for cementable crowns.

2.
J Esthet Restor Dent ; 36(6): 920-929, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38404208

RESUMEN

OBJECTIVES: To evaluate surface microhardness and gingival marginal adaptation of three different bulk-fill flowable resin composites (FB-RBCs) in Class V cavities with enamel or dentin margins before and after thermocycling (TMC). MATERIALS AND METHODS: Three available FB-RBCs were used; Palfique Bulk Flow (PaBF) (Tokuyama Dental), SDR Flow+ Bulk Fill Flowable (Dentsply Sirona), and I-Flow Bulk Fill (I-Dental). Thirty discs were prepared from each type of FB-RBCs. The discs were subjected to Vickers microhardness tester machine. Class V cavities were prepared on 180 molars. Gingival margins of half the specimens were prepared above CEJ and the other half below CEJ. Cavities were restored with FB-RBCs for gingival marginal adaptation test. Two-way ANOVA was used in microhardness, while three-way ANOVA was used for marginal adaptation. RESULTS: The used materials showed statistically significant differences in microhardness and marginal adaptation. CONCLUSIONS: Regarding microhardness, PaBF showed the highest value before TMC and SDR was the highest after TMC. Regarding marginal adaptation, SDR revealed the best marginal adaptation than PaBF and I-flow, either subjected to TMC or not. CLINICAL SIGNIFICANCE: The longevity of cervical restorations depend on both the location of the cavity margin and the material used. The microfractures in resin composite surface due to low surface microhardness as well as marginal gaps seen in laboratory studies could be considered as an indicative parameter for clinical problem associated with marginal differences.


Asunto(s)
Resinas Compuestas , Resinas Compuestas/química , Humanos , Dureza , Propiedades de Superficie , Adaptación Marginal Dental , Encía , Ensayo de Materiales , Restauración Dental Permanente/métodos
3.
BMC Oral Health ; 24(1): 410, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566034

RESUMEN

BACKGROUND: To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS: The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS: Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION: Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.


Asunto(s)
Tornillos Óseos , Implantes Dentales , Boca Edéntula , Humanos , Diseño Asistido por Computadora , Técnica de Impresión Dental , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado/métodos , Flujo de Trabajo
4.
BMC Oral Health ; 24(1): 73, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38212816

RESUMEN

BACKGROUND: The effect of 3D printing technology and build angle on the marginal fit of printed crowns is unclear. The objective of this research was to use digital light processing (DLP) and stereo-lithography (SLA)-based 3D printing to construct single restorations with varied build angles and to analyze the crowns' marginal fit. METHODS: A prepared resin first molar was scanned utilizing an optical scanner. Three build orientations were used to construct the specimens: 0, 45, and 90º. DLP and SLA technology were used to produce the casting patterns. A digital microscope was used to measure the marginal gaps. The effect of build orientation was statistically analyzed by using Two-way ANOVA followed by pair-wise Tukey test. RESULTS: Two-way ANOVA revealed a significant effect of printer technology and build angle on the marginal discrepancy of 3D printed crowns (p < 0.001). One-way ANOVA revealed that SLA printers (55.6 [± 13.59]) showed significantly better mean [± SD] marginal discrepancy in µm than DLP printers (72 [± 13.67]) (p < 0.001). Regarding build angle, one-way ANOVA revealed significant differences between the different angles. Tukeys post-hoc test revealed that 0° (48.5 [± 9.04]) had the significantly smallest marginal discrepancy followed by 45° (62.5 [± 8.05]) then 90° (80.5 [± 8.99]) (p < 0.001). CONCLUSION: The build orientation affects the marginal discrepancy of single crowns manufactured utilizing DLP and SLA.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Humanos , Diseño de Prótesis Dental , Impresión Tridimensional
5.
BMC Oral Health ; 24(1): 228, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38350901

RESUMEN

BACKGROUND: The purpose of this study is to evaluate the marginal adaptation of bulk-fill resin composites with different viscosities (paste-like and flowable) in Class II restorations using micro-CT imaging. METHODS: Forty extracted human molars were used. Mesial and distal Class II box cavities (approximately 3 mm x 3 mm x 4 mm) were prepared for each tooth, with cavity floors located 1 mm below the enamel-cementum junction. Following adhesive application, teeth were restored using eight different groups: Group XB: X-tra Base Bulk-fill Flowable (VOCO), Group XF: X-tra Fill Bulk-fill (VOCO), Group FB: Filtek Bulk-fill Posterior (3 M ESPE), Group FF: Filtek Bulk-fill Flowable (3 M ESPE), Group BB: Beautifil-Bulk (SHOFU), Group BF: Beautifil-Bulk Flowable (SHOFU), and Group CO: "as a control group", Clearfil Majesty Posterior (KURARAY) and Group CF: "as a control group", Clearfil Majesty Flow + Clearfil Majesty Posterior (KURARAY). The restored teeth underwent an aging protocol involving 1000 cycles in a water bath fluctuating between 5 ± 1.0 °C and 55 ± 1.0 °C. Post-aging, teeth were immersed in 50% silver nitrate solution for 24 h and then in a film developer solution for 8 h. Microleakage analysis was performed using micro-CT, evaluated with 3D Slicer software. A two-way ANOVA was employed for statistical analysis. RESULTS: Two-way ANOVA results indicated significant effects of both viscosity (p < 0.0001) and composite type (p < 0.0001) on marginal adaptation. Viscosity analysis (comparing flowable and paste-like) revealed no significant differences in the FB-FF, XB-XF and BB-BF groups but significant differences in the and CO-CF group, with flowable type exhibiting less microleakage than paste-like type. CONCLUSIONS: The study suggests that while the viscosity of bulk-fill composites did not significantly affect marginal adaptation, the brand of bulk-fill composite did influence it.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Humanos , Viscosidad , Restauración Dental Permanente/métodos , Microtomografía por Rayos X , Ensayo de Materiales , Diente Molar/diagnóstico por imagen
6.
J Pak Med Assoc ; 74(2): 282-286, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38419227

RESUMEN

OBJECTIVE: To evaluate the influence of polyether ether ketone coping crown on the adaptation of implant abutment. Methods: The vitro study was conducted at the department of Prosthodontics, Hainan Stomatological Hospital, China, from October 2021 to March 2022, and comprised patients undergoing implant surgery on first molar. Patients were divided into two groups, with group A patients receiving polyether ether ketone coping crowns, and group B receiving zirconia crowns. Replica technique was used to replicate the gap between the crowns and the abutments. The thickness of the silicone film was measured under the stereomicroscope, and the gap between the groups was compared. Data was analysed using SPSS 22. RESULTS: In group A, mean marginal gap was 82.43±25.00µm, and mean overall gap was 85.45±33.75µm. In group B, the corresponding values were 65.09±11.69µm and 78.04±26.67µm. There was a significant difference in the adaptation between the groups at the marginal and overall measurement points (p<0.05). Conclusion: Marginal and internal adaptations of polyether ether ketone coping crown for abutment could be considered clinically acceptable.


Asunto(s)
Benzofenonas , Cetonas , Polietilenglicoles , Polímeros , Humanos , Adaptación Psicológica , Éteres
7.
J Prosthodont ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38513224

RESUMEN

PURPOSE: To assess vertical and horizontal fit, screw removal torque, and stress analysis (considered biomechanical aspects) of full-arch implant frameworks manufactured in Ti-6Al-4V through milling, and additive manufacturing Direct Metal Laser Sintering (DMLS) and Electron Beam Melting (EBM), and the effect of the thermo-mechanical treatment Hot Isostatic Pressing (HIP) as a post-treatment after manufacturing. MATERIAL AND METHODS: Maxillary full-arch implant frameworks were made by milling, DMLS, and EBM. The biomechanical assessments were screw removal torque, strain-gauge analyses, and vertical and horizontal marginal fits. The vertical fit was assessed by the single-screw test and with all screws tightened. All frameworks were submitted to a standardized HIP cycle (920°C, 1000 bar pressure, 2 h), and the tests were repeated (α = 0.05). RESULTS: At the initial time, milled frameworks presented higher screw removal torque values, and DMLS and EBM frameworks presented lower levels of strain. Using the single-screw test, milled and DMLS frameworks presented higher vertical fit values, and with all screws tightened and horizontally, higher fit values were found for milled frameworks, followed by DMLS and EBM. After HIP, milling and EBM frameworks presented higher screw removal torque values; the lowest strain values were found for EBM. Using the single-screw test, milled and DMLS frameworks presented higher vertical fit values, and with all screws tightened and horizontally no differences were found. CONCLUSIONS: DMLS and EBM full-arch frameworks presented adequate values of screw removal torque, strain, and marginal fit, although the worst values of marginal fit were found for EBM frameworks. The HIP cycle enhanced the screw removal torque of milled and EBM frameworks and reduced the strain values of milled frameworks. The HIP represents a reliable post-treatment for Ti-6Al-4V dental prostheses produced by milling and EBM technologies.

8.
Medicina (Kaunas) ; 60(6)2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38929622

RESUMEN

Background and objective: The aim of this randomized split-mouth study-controlled clinical trial was to compare the 2-year clinical performance of resin composite restorations placed at non-caries cervical lesions (NCCL) with one-step self-etch, total-etch, and selective enamel etch and self-etch adhesive techniques. Materials and methods: Thirty-two patients received three resin composite restorations each at NCCLs (Tetric EvoCeram/Ivoclar/Vivadent), bonded with a total-etch adhesive agent (ExciTE F/Ivoclar/Vivadent) and a self-etch (AdheSE One F/Ivoclar/Vivadent) without and with selective enamel etching. All restorations were evaluated by two examiners at baseline, 6-, 12-, 18-, and 24-months with FDI clinical criteria (post-operation regarding retention, caries occurrence, marginal adaptation, and marginal staining). A logistic regression analysis, a Cohen's kappa statistic, a multifactorial analysis, and X2 were performed with generalized estimating equations. Results: After 2 years, the retention rate was 86.8% for total etch, 92.26% for self-etch, and 93.63% for selective enamel etching and self-etch. No caries was detected on the restorations. Concerning marginal adaptation, the clinically perfect restorations were 26.9% for the total-etch technique, 16% for self-etch, and 25.9% for selective enamel etch and self-etch. The logistic regression model revealed that only time reduced the probability of perfect marginal adaptation. Conclusions: All three adhesive strategies provided restorations with no significant differences in the retention rate or marginal adaptation, whereas the total etch yielded better performance for marginal staining. All restorations were assessed as clinically acceptable after 2 years.


Asunto(s)
Restauración Dental Permanente , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Restauración Dental Permanente/métodos , Restauración Dental Permanente/estadística & datos numéricos , Resinas Compuestas/uso terapéutico , Cuello del Diente , Recubrimiento Dental Adhesivo/métodos , Caries Dental/terapia
9.
J Esthet Restor Dent ; 35(4): 646-656, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36478368

RESUMEN

OBJECTIVE: The aim of this scoping review was to analyze the available evidence on the preheating process and its effects on physicochemical properties of composite resins. MATERIALS AND METHODS: A systematic search was performed in August 2021 using PubMed/Medline, Embase, Scopus, and ISI Web of Science databases and gray literature without language or date restriction. Inclusion criteria were in vitro studies that assessed the physicochemical properties and marginal adaptation of preheated composite. Exclusion criteria were studies with experimental composite, literature reviews, clinical studies. Data from selected studies were qualitatively analyzed. RESULTS: In total, 104 studies were found from which 39 were included. The most used composite resin was Filtek Z350 XT (3 M/ESPE), preheated at 68°C in a Calset device (AdDent Inc., Danbury, CT, USA) for 5 or 15 min. Most studies showed decreased viscosity, increased conversion degree and microhardness of composite resins, and better marginal adaptation of direct and indirect restorations. Also, flexural strength was not affected, and data about bond strength were inconclusive due to heterogeneity among studies. CONCLUSION: The parameters used for preheating composite resins are heterogeneous. Preheating decreased viscosity, increased the conversion degree and microhardness of composite resins, and improved the marginal adaptation of direct and indirect restorations. CLINICAL SIGNIFICANCE: The analysis of evidence showed a high heterogeneity among preheating protocols. Preheating may benefit the handling and physicochemical properties of composite resins.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Resinas Compuestas/química , Ensayo de Materiales , Viscosidad
10.
BMC Oral Health ; 23(1): 546, 2023 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-37559037

RESUMEN

BACKGROUND: Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK) crowns in relation to the essential requirements of successful restorations, such as fracture resistance or margin adaptation. The purpose of this study was to evaluate the effect of the coping materials zirconia or PEEK with different fabrication techniques on the vertical marginal gap and fracture resistance of posterior crowns with composite veneering. METHODS: Ceramic copings (n = 18) restoring mandibular first molar were fabricated from zirconia (Zircon.x, Presidentdental, Germany), milled PEEK (PEEK CAD) (breCAM.BioHPP, Bredent, Germany) and pressed PEEK (PEEK Press) (BioHPP Granules, Bredent, Germany) six specimens each (n = 6). The copings were veneered with high impact polymer composite (HIPC) material (breCAM.HIPC, Bredent, Germany). The vertical marginal gap was captured under a magnification of 40X. Five equidistant marks on each surface of the die distinguished the points of measurement for a total of 20 readings per sample. The analysis was completed using an image analysis system (ImageJ 1.53t, National Institute of Health, USA). The specimens were loaded to failure at a crosshead speed of 1 mm/min and the load at failure was recorded to measure the fracture resistance. RESULTS: The marginal gap was analyzed using one-way ANOVA followed by Tukey's post hoc test. Fracture resistance was analyzed using Welch one-way ANOVA followed by the Games-Howell post hoc test. Marginal gap values showed a significant difference between the tested groups, with zirconia having significantly lower gap values (48.67 ± 11.98 µm) than both the PEEK CAD (108.00 ± 20.08 µm) and Press groups (108.00 ± 25.10 µm) (p < 0.001). However, the results of fracture resistance showed no significant difference (p = 0.06) with 1687.47 ± 253.29 N, 2156.82 ± 407.64 N, 2436.72 ± 725.93 N for zirconia, PEEK CAD, and Press, respectively. The significance level was p < 0.05. CONCLUSIONS: Zirconia framework crowns have a smaller vertical marginal gap than milled and pressed PEEK crowns. Crowns fabricated from zirconia, PEEK CAD, or PEEK Press frameworks and veneered with composite resin have comparable fracture resistance lower than the maximum biting force in the posterior region. CLINICAL RELEVANCE: Posterior crowns with zirconia frameworks are preferred over milled and pressed PEEK frameworks regarding margin adaptation, although all can safely survive the maximum occlusal forces without fracture.


Asunto(s)
Coronas , Porcelana Dental , Humanos , Polietilenglicoles , Cetonas , Adaptación Psicológica , Diseño Asistido por Computadora , Ensayo de Materiales , Diseño de Prótesis Dental
11.
BMC Oral Health ; 23(1): 706, 2023 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-37777724

RESUMEN

BACKGROUND: This study aimed to assess the effect of blood contamination on marginal adaptation of cold ceramic (CC) and mineral trioxide aggregate (MTA) Angelus using scanning electron microscopy (SEM). METHODS: This in vitro experimental study was conducted on 24 extracted single-rooted human teeth. After cleaning and shaping, the root canals were filled with lateral compaction technique. The apical 3 mm of the roots was cut, and cavities with 3 mm depth were created at the apex. The teeth were randomly assigned to two group (n = 12) for the application of CC and MTA Angelus as retrograde filling materials. CC and MTA Angelus were prepared by mixing the powder with blood, and applied in the cavities. After 24 h, their marginal adaptation to the canal walls was assessed by SEM. Data were statistically analyzed by t-test (alpha = 0.05). RESULTS: The mean marginal gap was 8.98 µm in the CC, and 16.26 µm in the MTA Angelus group; this difference was statistically significant (P < 0.001). CONCLUSIONS: The present in vitro study revealed that following complete blood contamination of powder, CC showed significantly superior marginal adaptation than MTA Angelus as shown by SEM assessment.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Humanos , Materiales de Obturación del Conducto Radicular/farmacología , Microscopía Electrónica de Rastreo , Compuestos de Calcio , Electrones , Polvos , Silicatos/farmacología , Óxidos/farmacología , Combinación de Medicamentos , Compuestos de Aluminio/farmacología
12.
BMC Oral Health ; 23(1): 938, 2023 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-38017480

RESUMEN

BACKGROUND: Treated dentin matrix hydrogel (TDMH) has been introduced as a novel injectable direct pulp capping material. In this regard, this study aimed to evaluate its marginal adaptation, physicochemical and rheological properties for the development of clinically feasible TDMH. METHODS: TDMH was applied to the pulp floor of prepared Class I cavities (n = 5), marginal adaptation was assessed by SEM at 1000 X magnification to detect gap between dentin and filling material. Five syringes were filled with TDMH and placed between the compression plates of a universal testing machine to evaluate injectability and gelation time was also evaluated by test vial inverting method. The microstructures of lyophilized TDMH were observed by SEM. Moreover, TDMH discs (n = 5) were prepared and the water uptake (%) was determined based on the equilibrium swelling theory state of hydrogels. Its solubility was measured after one week by the ISO standard method. Rheological behaviours of TDMH (n = 5) were analysed with a rotational rheometer by computing their complex shear modulus G* and their associated storage modulus (G') and loss modulus (G''). Statistical analysis was performed using F test (ANOVA) with repeated measures and Post Hoc Test (p = 0.05). RESULTS: TDMH presented an overall 92.20 ± 2.95% of continuous margins. It exhibited gelation during the first minute, and injectability mean was 66 ± 0.36%. TDMH showed a highly porous structure, and the pores were interconnected with an average diameter about 5.09 ± 3.17 µm. Swelling equilibrium gradually reached at 6 days up to 377%. The prepared hydrogels and maintained their shape after absorbing over three times their original weight of water. TDMH fulfilled the requirements of ISO 6876, demonstrating a weight loss of 1.98 ± 0.09% and linear viscoelastic behaviour with G` 479.2 ± 12.7 and G`` 230.8 ± 13.8. CONCLUSIONS: TDMH provided good marginal adaptation, appropriate physicochemical and viscoelastic properties support its use as a novel direct pulp capping material in future clinical applications.


Asunto(s)
Recubrimiento de la Pulpa Dental , Hidrogeles , Humanos , Hidrogeles/química , Dentina , Agua , Regeneración , Pulpa Dental
13.
BMC Oral Health ; 23(1): 613, 2023 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-37649061

RESUMEN

BACKGROUND: Straight preparable abutments and titanium bases (ti-base) can be used to support single-unit screw-retained lithium disilicate implant-supported restorations. The choice between using both abutments depends on many factors. The purpose of this in vitro study was to compare the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to straight preparable abutments and ti-bases. METHODS: Twenty laboratory implant analogs (Straumann Bone Level; Straumann AG) were randomly divided into 2 groups (n = 10 each) according to the type of the abutment used. Preparable abutment group and ti-base group. Lithium disilicate crowns were used to restore the specimens. All specimens were subjected to thermocycling (from 5 to 55 °C for 2000 cycles) followed by cyclic loading (120 000 cycles). The vertical marginal gap between the abutment finish line and the most apical part of the crown was measured in (µm) by using a stereomicroscope after cementation and after thermocycling and cyclic loading. A spectrophotometer was used to evaluate the masking ability of the specimens after cementation. The load required to fracture the crowns was measured in Newtons (N) by using a universal testing machine after thermocycling and cyclic loading. The Shapiro-Wilk test of normality was used. The appropriate statistical test was used. RESULTS: Regarding the masking ability, the color difference (∆E) showed no statistically significant difference between the ti-base group (2.6 ± 0.2) and the preparable abutment group (2.6 ± 0.3) (P = .888). The average of the microgap values (µm) was greater in ti-basegroup after cementation (13.9 ± 9.2) than preparable group (7.63 ± 1.78) with no statistically significant difference between the 2 groups (P = .49). After cyclic loading and thermocycling, the average microgap values (µm) was significantly greater in the ti base group (21.3 ± 7.4) than in preparable group (13.3 ± 1.5) (P = .02). The load required to fracture the specimens was greater in the preparable group (1671.5 ± 143.8) than in the ti-base group (1550.2 ± 157.5) with no statistically significant difference between the 2 groups (P = .089). CONCLUSION: The abutments used in the present study did not compromise the masking ability of the screw-retained lithium disilicate implant supported crowns. Moreover, the crowns cemented to preparable abutments had better marginal adaptation and higher fracture resistance when compared to those cemented to ti-bases. CLINICAL IMPLICATIONS: Straight preparable abutments are considered as an alternative to the ti-bases when restoring single screw-retained lithium disilicate implant-supported crowns with comparable fracture resistance, marginal adaptation, and masking ability.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Tornillos Óseos , Coronas
14.
BMC Oral Health ; 23(1): 933, 2023 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-38012568

RESUMEN

BACKGROUND: The successful integration of resin-based dental adhesives significantly impacts restorative dentistry, providing efficient and aesthetically pleasing caries treatments. Among various adhesives, one-step self-etching adhesives (1-SEAs) have gained popularity due to their simplicity and short application time. However, concerns have been raised regarding their bonding performance and marginal adaptation characteristics, which differ from two-step self-etching adhesives (2-SEAs) and three-step etch-and-rinse adhesives. Additionally, light-cured bonding materials may encounter challenges in deep cavities and inaccessible areas, necessitating extended light irradiation time. Autocured bonding materials are a potential solution, but limited comparative studies have been conducted on their performance. METHODS: In this in vitro study, we evaluated a new autocured universal bonding material (Bondmer Lightless 2) and compared the results with recent light-cured bonding materials. Microshear bond strength (µSBS) tests were performed on 25 human molars using five different combinations of adhesives and composite resins: Bondmer Lightless 2 with Estelite Bulk Fill Flow (BE group), Bondmer Lightless 2 with a prototype composite resin (BO group), Prime&Bond Universal with SDR flow + (PS group), Scotchbond Universal with Filtek Bulk Fill (SF group), and G-Premio Bond with Gracefil BulkFlo (GG group). The bond strengths and failure modes were assessed using a universal testing machine and scanning electron microscope (SEM), respectively. Marginal adaptation was evaluated using swept-source optical coherence tomography (SS-OCT) and confocal laser scanning microscopy (CLSM) on 40 sound bovine maxillary incisors. RESULTS: The µSBS test showed no significant differences in bond strength among the tested groups. Most failure modes were observed at the bond interface between the adhesive and the dentin. The autocured bonding material demonstrated significantly higher marginal adaptation (SI%) than PS, SF, and GG. The CLSM images corresponded with gaps observed in the SS-OCT images, indicating improved marginal sealing in the autocured group. CONCLUSIONS: The new autocured universal bonding material exhibited comparable bond strength to a conventional light-cured material while demonstrating a superior marginal adaptation level. This finding suggested that the autocured material could be a valuable alternative, especially when extended light irradiation would pose a challenge. Further clinical studies would be warranted to evaluate the performance of the autocured bonding material in actual restorative dental practice.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Animales , Bovinos , Humanos , Recubrimiento Dental Adhesivo/métodos , Resinas Compuestas/química , Materiales Dentales/química , Cementos de Resina/química , Dentina , Ensayo de Materiales , Resistencia a la Tracción
15.
Int J Comput Dent ; 0(0): 0, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37823542

RESUMEN

AIM: To evaluate and compare the marginal adaptation and fracture resistance of resin matrix ceramic crowns fabricated using 3-dimensional (3D) printing and computer aided design/computer aided manufacturing (CAD/CAM) milling technology. MATERIALS AND METHODS: Thirty extracted human maxillary first premolars were prepared to receive crown restorations and grouped into 3 groups according to 3 different crown materials (n = 10): VE: teeth restored with milled Vita Enamic, CS: teeth restored with milled Cerasmart 270 and VSC: teeth restored with 3D-printed VarseoSmile Crown Plus. Marginal analysis was performed with the aid of a digital microscope at (230x) magnification, both before and after cementation with self-adhesive resin cement and analyzed with Image J analysis software. The fracture loads for each sample were then recorded using a universal testing machine in a single load-to-failure test up until the crowns failed. RESULTS: The lowest marginal gap values were recorded for VSC before (8.03 µm) and after (15.07 µm) cementation with significant difference compared to the other crown materials (p <0.05), while the differences between the milled groups were non-significant both before, (CS (11.35 µm) and VE (11.86 µm)), and after cementation, (CS (20.01 µm) and VE (21.08 µm)). In terms of fracture resistance, VE recorded significantly lower fracture load values (727.8 N) (p <0.05) than the crowns fabricated from CS (1213.8 N) and VSC (1181.5 N), which showed no statistically significant differences between each other. CONCLUSION: 3D printed definitive crowns outperformed CAD/CAM milled crowns in terms of marginal adaptation, along with comparable fracture resistance values.

16.
J Pak Med Assoc ; 73(3): 567-571, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36932761

RESUMEN

OBJECTIVE: To determine the difference in the marginal accuracy at buccal, lingual, mesial and distal margins of temporary crowns fabricated with bisacryl-based temporary crown material. METHODS: The in-vitro, experimental, laboratory-based study was conducted at the Aga Khan University, Karachi, from September to December 2019, and comprised two bisacryl-based temporary crown material, Integrity and Protemp 4, which were used to fabricate a sample of 24 temporary crowns. A pre-operative polyvinyl siloxane impression served as a template for temporary crown fabrication. A right mandibular molar tooth on a typodont was prepared to receive a crown. The provisional crown material was syringed onto the template and was allowed to cure. All four surfaces of the crown were observed under a stereomicroscope equipped with digital single-lens reflex camera at 25.6x magnification. An image of each surface was captured and a photographic record was maintained. An image processing software was used for the measurement of marginal discrepancy. Marginal accuracy among the four surfaces was assessed. Data was analysed using SPSS 23. RESULTS: Mean marginal discrepancy for provisional crowns fabricated with Protemp 4 and Integrity was 410±222µm and 319±176µm, respectively. The marginal discrepancy between the two groups was statistically significant (p=0.027), with buccal margin exhibiting the most discrepancy (p<0.01). CONCLUSIONS: Integrity showed less microleakage than Protemp 4. Among all the walls, the buccal wall showed the most microleakage. Marginal accuracy was found to be dependent upon the type of provisional crown material and the side of the prepared axial wall.


Asunto(s)
Coronas , Proyectos de Investigación , Humanos
17.
J Contemp Dent Pract ; 24(11): 853-858, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38238272

RESUMEN

AIMS: This study aimed to assess the marginal and internal adaptation of provisional crowns fabricated from polymethyl methacrylate (PMMA) blocks by the computer-aided design/computer-aided manufacturing (CAD/CAM) system, autopolymerizing PMMA, and acrylic base composite resin. MATERIALS AND METHODS: In this in vitro experimental study, a brass die was obtained, and provisional crowns were fabricated in three groups using Teliocad PMMA blocks by the CAD/CAM system, Tempron GC auto-polymerizing PMMA, and Bisico acrylic base composite resin (n = 7 in each group). The provisional crowns were coded and randomly placed on the die. Their marginal adaptation was evaluated under a stereomicroscope at 40× magnification, while their internal adaptation was assessed by the replica technique. Data were analyzed by one-way analysis of variance (ANOVA) (α = 0.05). RESULTS: The mean marginal gap was the highest in autopolymerizing PMMA and the lowest in the CAD/CAM PMMA group (p < 0.05). The mean marginal gap in the autopolymerizing PMMA group was significantly higher than that in the resin material (p = 0.014) and CAD/CAM PMMA (p = 0.000) groups. The difference between the resin material and CAD/CAM PMMA groups was not significant (p = 0.13). The mean internal gap was the highest in autopolymerizing PMMA group and the lowest in CAD/CAM PMMA group (p < 0.05). The mean internal gap in autopolymerizing PMMA group was significantly higher than that in composite resin (p = 0.002) and CAD/CAM PMMA (p = 0.00) groups. The difference between the resin material and CAD/CAM PMMA groups was not significant (p = 0.322). CONCLUSION: Computer-aided design/Computer-aided manufacturing PMMA provisional crowns showed the highest marginal and internal adaptation followed by acrylic base resin material crowns. CLINICAL SIGNIFICANCE: Computer-aided design/computer-aided manufacturing PMMA crowns demonstrate superior marginal and internal adaptation compared with autopolymerizing PMMA and acrylic base composite resin crowns, suggesting CAD/CAM technology's potential for enhancing clinical outcomes. How to cite this article: Jalalian E, Younesi F, Golalipour S, et al. Assessment of Marginal and Internal Adaptation in Provisional Crowns Utilizing Three Distinct Materials. J Contemp Dent Pract 2023;24(11):853-858.


Asunto(s)
Bisfenol A Glicidil Metacrilato , Diseño de Prótesis Dental , Polimetil Metacrilato , Coronas , Resinas Compuestas , Resinas Acrílicas , Diseño Asistido por Computadora , Adaptación Marginal Dental , Ensayo de Materiales
18.
J Contemp Dent Pract ; 24(9): 638-644, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38152935

RESUMEN

AIMS: This study compared the effects of orthograde and retrograde methods on marginal adaptation, surface hardness, and push-out bond strength (POBS) of three calcium silicate-based used in endodontic surgery. MATERIALS AND METHODS: Ninety single-rooted human mandibular premolars were randomly assigned into six groups (n = 15/group): groups I and II, ProRoot mineral trioxide aggregate (MTA) with orthograde and retrograde methods; groups III and IV, Biodentine (BD) with orthograde and retrograde methods; groups V and VI, iRoot BP Plus (BP-RPM) with orthograde and retrograde methods. After obturation, the apical 3 mm of each root was sectioned into two 1-mm-thick root slices and evaluated for marginal adaptation using a scanning electron microscope, surface hardness using Vickers hardness tester and POBS using a universal testing machine. RESULTS: Orthograde placement had a higher maximum gap width than retrograde placement (p < 0.05), but there was no significant difference among the tested materials (p > 0.05). Biodentine exhibited lower surface hardness than ProRoot MTA and iRoot BP Plus (p < 0.05), but there was no significant difference between ProRoot MTA and iRoot BP Plus (p > 0.05). Orthograde placement had higher POBS compared with retrograde placement (p < 0.05). Biodentine had higher POBS than iRoot BP Plus (p < 0.05), but no significant difference from ProRoot MTA (p > 0.05). The failure mode was mainly mixed for all the tested materials regardless of material type or placement technique. CONCLUSION: The retrograde method had better marginal adaptation; however, the orthograde method provided better dislodgement resistance. Biodentine had lower surface hardness than MTA and iRoot BP Plus with both techniques, whereas iRoot BP Plus demonstrated lower dislodging resistance than BD. CLINICAL SIGNIFICANCE: The current findings suggest that orthograde technique, a simpler periapical surgery, with ProRoot MTA provides potentially better surface hardness and POBS than BD and iRoot BP Plus in single-canal teeth.


Asunto(s)
Compuestos de Calcio , Materiales de Obturación del Conducto Radicular , Humanos , Dureza , Compuestos de Calcio/química , Silicatos/química , Óxidos/química , Combinación de Medicamentos , Compuestos de Aluminio/química , Materiales de Obturación del Conducto Radicular/química
19.
Niger J Clin Pract ; 26(6): 701-708, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37470642

RESUMEN

Background: Polyether ether ketone (PEEK) has emerged as a new thermoplastic material with potential applications as a restorative material. Aim: This study aimed to evaluate the marginal adaptation of PEEK copings compared to zirconia copings using field emission scanning electron microscopy. Materials and Methods: A freshly extracted maxillary central incisor was prepared for a full-coverage restoration following standard principles of tooth preparation. The tooth was sent to a laboratory for fabrication of samples using computer-aided design and manufacturing (CAD/CAM). Twenty samples of polyether ether ketone (PEEK) copings (group A) and 20 of zirconia copings were fabricated (group B). The copings were scanned under a field emission scanning electron microscope and measurements were taken at four distinct points. The marginal adaptation over the buccal, lingual, mesial, and distal margins for both groups was evaluated. One-way analysis of variance (ANOVA) and independent t test were applied. Results: Our findings indicate that PEEK showed better marginal adaptation than zirconia at all measurement points. The mean marginal gap value of the PEEK group was 33.99 ± 8.81 µm and of the zirconia group was 56.21 ± 15.07 µm. On comparing marginal adaptation among the mesial, distal, buccal, and lingual aspects, PEEK showed better adaptation on all four margins, with the best adaptation on the buccal margin that had the lowest mean gap value of 29.27 ± 6.07 µm. The zirconia group adapted best at the distal margin, with a lowest mean gap value of 53.58 ± 15.25 µm (P ≤ 0.05). Conclusion: PEEK copings had better marginal adaptation and fit compared to zirconia copings. It may have applications as a restorative material in fixed prostheses.


Asunto(s)
Diseño Asistido por Computadora , Polietilenglicoles , Humanos , Cetonas , Circonio , Adaptación Psicológica , Éteres
20.
J Evid Based Dent Pract ; 23(4): 101914, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38035892

RESUMEN

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Tabesh M, Nejatidanesh F, Savabi G, Davoudi A, Savabi O. Marginal accuracy of lithium disilicate full coverage crowns made by direct and indirect digital or conventional workflows: a systematic review and meta-analysis. J Prosthodont. 2022;31(9):744-753. doi:10.1111/jopr.13515. SOURCE OF FUNDING: Dental Research Center, Isfahan University of Medical Sciences Research Grant #298095. TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda