Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 248
Filtrar
1.
NMR Biomed ; 37(10): e5178, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38784970

RESUMEN

Phosphorus (31P) magnetic resonance spectroscopic imaging (MRSI) can serve as a critical tool for more direct quantification of brain energy metabolism, tissue pH, and cell membrane turnover. However, the low concentration of 31P metabolites in biological tissue may result in low signal-to-noise ratio (SNR) in 31P MRS images. In this work, we present an innovative design and construction of a 31P radiofrequency coil for whole-brain MRSI at 7 T. Our coil builds on current literature in ultra-high field 31P coil design and offers complete coverage of the brain, including the cerebellum and brainstem. The coil consists of an actively detunable volume transmit (Tx) resonator and a custom 24-channel receive (Rx) array. The volume Tx resonator is a 16-rung high-pass birdcage coil. The Rx coil consists of a 24-element phased array composed of catered loop shapes and sizes built onto a custom, close-fitting, head-shaped housing. The Rx array was designed to provide complete coverage of the head, while minimizing mutual coupling. The Rx configuration had a mean S 11 reflection coefficient better than -20 decibels (dB) when the coil was loaded with a human head. The mean mutual coupling ( S 21 ) among Rx elements, when loaded with a human head, was -16 dB. In phantom imaging, the phased array produced a central SNR that was 4.4-fold higher than the corresponding central SNR when operating the 31P birdcage as a transceiver. The peripheral SNR was 12-fold higher when applying the optimized phased array. In vivo 3D 31P MRSI experiments produced high-quality spectra in the cerebrum gray and white matter, as well as in the cerebellum. Characteristic phosphorus metabolites related to adenosine triphosphate metabolism and cell membrane turnover were distinguishable across all brain regions. In summary, our results demonstrate the potential of our novel coil for accurate, whole-brain 31P metabolite quantification.


Asunto(s)
Encéfalo , Fantasmas de Imagen , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Fósforo , Espectroscopía de Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Relación Señal-Ruido , Isótopos de Fósforo
2.
Sensors (Basel) ; 24(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38894088

RESUMEN

In this paper, a wide-band, low-profile antenna is presented for a high-integration phased array system. The proposed antenna, implemented using a tightly coupled array, operates over roughly the X-K frequency band and is performant at 8 GHz-18.5 GHz. The antenna can scan to ±60 degrees in both the E- and H-planes. Compared to previous tightly coupled antennas with smaller element spacing, the antenna in this paper reaches 9.4 mm, which corresponds to 0.58 λ of high frequency, suitable for engineering application conditions in production. The antenna can be soldered to BGA T/R chips in this space. Additionally, to facilitate flexible assembly for large arrays, the antenna is manufactured modularly using four elements and its parasitic radiation is analyzed. Then, a method for repressing parasitic radiation is presented. Finally, the antenna is fabricated and measured in a microwave chamber, exhibiting an excellent pattern and scanning radiation. The measured performance agrees with the full-wave finite array simulations.

3.
Sensors (Basel) ; 24(2)2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38257408

RESUMEN

In this letter, a dual-polarized metal Vivaldi phased array antenna composed of independent structural elements is proposed, covering 6-18 GHz. By designing Vivaldi elements with a flexible and complementary structure, arrays of arbitrary shapes and scales can be constructed. The resonance caused by structural discontinuity is critically studied and eliminated to ensure good performance across the entire band. The antenna elements are fed by 50-Ohm SSMP connectors and manufactured from 2A12 aluminum alloy. An array prototype consisting of 8 × 8 dual-polarized metal has been fabricated and tested with active transmit/receive (T/R) modules to demonstrate the design concept. The array exhibits excellent beam-scanning characteristics in both the E-plane and H-plane, within the scanning range without grating lobes, which shows good agreement with the simulated results. The measured gain results are within the range of 15.2 to 24.8 dBi, and the aperture efficiencies are greater than 91% in the entire operating band. The wideband antenna technology involved in this study can effectively help increase the capacity of communication systems and meets the intentions of the Special Issue.

4.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38544245

RESUMEN

This paper presents a 5G new radio (NR) FR2 beamforming system with an integrated transceiver module. A real-time operating module providing enhanced flexibility and capability has been proposed. The integrated RF beamforming system with an integrated transceiver module can be operated in 8Tx-8Rx mode configuration simultaneously. A series-fed structure 8 × 7 microstrip antenna array for compact size and improved directivity is employed in the RF beamforming module. The RF beamforming module incorporates a custom 28 GHz, eight-channel fully differential beamforming IC (BFIC). An eight-channel BFIC in a phased-array beamforming system offers advantages in terms of increased antenna density and improved beam steering precision. The RF beamforming module is integrated with an RF transceiver module that enables the simultaneous up-conversion and down-conversion of the baseband signal. The RF transmitter module consists of a transmitter, a receiver, a signal generator, a power supply, and a control unit. The RF beamforming system can scan horizontally from -50° to +50° with a step of 10°. To achieve an optimized beam pattern, a calibration was conducted. The transmit and receive conversion gain of around 20 dB is achieved with the transceiver module. To verify the communication performance of the manufactured integrated RF beamforming system, a real-time wireless video transmission/reception test was performed at a frequency of 28 GHz, and the video file was transmitted smoothly in real time without interruption within a range of ±50°.

5.
Sensors (Basel) ; 24(18)2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39338873

RESUMEN

This paper presents a novel 3 × 3 phased array antenna optimized for 4 GHz operation, achieving a realized gain of 13.2 dBi and enabling 30-degree beam steering with a minimal capacitance variation of 1.5 pF. The design features a series aperture-coupled feeding mechanism that not only reduces the antenna's size but also simplifies the fabrication process, making the device both cost-effective and compact. Integrating cost-efficient quadrature-hybrid phase shifters and novel power splitters with cascaded quadrature hybrids ensures uniform power distribution and precise beam steering. The innovative use of these components addresses common challenges in phased array systems, such as space constraints, high costs, and complex power distribution.

6.
Sensors (Basel) ; 24(19)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39409412

RESUMEN

This paper presents a study on residual stress measurement in wire-arc additively manufactured (WAAM) titanium samples using the non-destructive method of phased array ultrasonics. The contour method (CM) was used for the verification of the phased array ultrasonic results. This allowed for a comparison of measurement methods to understand the effects on the distribution of residual stress (RS) within Ti-6Al-4V samples and the effectiveness of measurement of residual stress using phased array ultrasonics. From the results of the experiments, the phased array ultrasonic data were found to be in good agreement with the CM results and displayed similar residual stress distributions in the samples. The results of the individual elements of the phased array were also compared and an improvement in accuracy was found. From per-element results, anomalies were found and could be mitigated with the ability to average the results by using phased array ultrasonics. Therefore, based on these results, there is a strong case for the benefits of using phased array ultrasonics as a method of residual stress measurement for WAAM Ti-6Al-4V components over other existing residual stress measurement techniques.

7.
Sensors (Basel) ; 24(2)2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38257714

RESUMEN

The simultaneous transmit and receive (STAR) array system provides higher radiation gain and data rate compared to traditional radio system. Because of the various mutual couplings between each pair of transmit and receive elements, it is a great challenge to suppress the incident self-interference power at multiple receive elements, which is usually much higher than the desired signal of interest (SoI) power and causes the saturation of receive links and the distortion of the digital SoI. In this paper, we propose an optimized method for transmit beamforming based on radiation power constraints and transmit power control. Through adaptive transmit beamforming, high isolation between the transmit array and each receive link is achieved, minimizing the self-interference power at each receiving element. This method effectively reduces the self-interference power, avoiding distortion of the SoI digital signal caused by limited-bit analog-to-digital converters (ADCs). Simulation results demonstrate that this optimized transmit beamforming method can achieve more than 100 dB effective isotropic isolation (EII) on a 32-element two-dimensional phased array designed in HFSS, reducing the maximum incident self-interference power at the receive channels by approximately 35 dB, while effectively controlling the attenuation of the transmit gain. We also present the advantages in receive subarray isolation and lower ADCs digits under the transmit ABF method.

8.
Sensors (Basel) ; 24(16)2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39204901

RESUMEN

High-strength bolts are crucial load-bearing components of wind turbine towers. They are highly susceptible to fatigue cracks over long-term service and require timely detection. However, due to the structural complexity and hidden nature of the cracks in wind turbine tower bolts, the small size of the cracks, and their variable propagation directions, detection signals carrying crack information are often drowned out by dense thread signals. Existing non-destructive testing methods are unable to quickly and accurately characterize small cracks at the thread roots. Therefore, we propose an ultrasonic phased array element arrangement method based on the Fermat spiral array. This method can greatly increase the fill rate of the phased array with small element spacing while reducing the effects of grating and sidelobes, thereby achieving high-energy excitation and accurate imaging with the ultrasonic phased array. This has significant theoretical and engineering application value for ensuring the safe and reliable service of key wind turbine components and for promoting the technological development of the wind power industry.

9.
Sensors (Basel) ; 24(17)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39275546

RESUMEN

Flexible ultrasonic devices represent a feasible technology for providing timely signal detection and even a non-invasive disease treatment for the human brain. However, the deformation of the devices is always accompanied by a change in the acoustic field, making it hard for accurate focusing. Herein, we report a stable and flexible transducer. This device can generate a high-intensity acoustic signal with a controllable acoustic field even when the device is bent. The key is to use a low-impedance piezoelectric material and an island-bridge device structure, as well as to design a unique time-reversal algorithm to correct the deviation of signals after transcranial propagation. To provide an in-depth study of the acoustic field of flexible devices, we also analyze the effects of mechanical deformation and structural parameters on the corresponding acoustic response.

10.
Sensors (Basel) ; 24(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38793914

RESUMEN

A compact circularly polarized non-resonant slotted waveguide antenna array is proposed with the aim of achieving wide-angle scanning, circular polarization, and low side-lobe levels. The designed antenna demonstrates a scanning range of +11° to +13° in the frequency domain and a beam scanning range of -45° to +45° in the phase domain. This design exhibits significant advantages for low-cost two-dimensional electronic scanning circularly polarized arrays. It employs a compact element that reduces the aperture area by 50% compared to traditional circular polarization cavities. Additionally, the staggered array method is employed to achieve an element spacing of 0.57λ within the azimuth plane. Isolation gaps were introduced into the array to enhance the circular polarization performance of non-resonant arrays. The Taylor synthesis method was employed to reduce the side-lobe levels. A prototype was designed, fabricated, and measured. The results indicate superior radiation efficiency, favorable VSWR levels, and an axis ratio maintenance below 3 dB across the scanning range. The proposed antenna and methodology effectively broaden the beam scanning angle of circularly polarized slotted waveguide array antennas.

11.
Sensors (Basel) ; 24(14)2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39066120

RESUMEN

The next generation phased array radio telescopes, such as the Square Kilometre Array (SKA) low frequency aperture array, suffer from RF interference (RFI) because of the large field of view of antenna element. The classical station beamformer used in SKA-low is resource efficient but cannot deal with the unknown sidelobe RFI. A real-time adaptive beamforming strategy is proposed for SKA-low station, which trades the capability of adaptive RFI nulling at an acceptably cost, it doesn't require hardware redesign but only modifies the firmware accordingly. The proposed strategy uses a Parallel Least Mean Square (PLMS) algorithm, which has a computational complexity of 4N+2 and can be performed in parallel. Beam pattern and output SINR simulation results show deeply nulling performance to sidelobe RFI, as well as good mainlobe response similar to the classical beamformer. The convergence performance depends on the signal-and-interference environments and step size, wherein too large a step size leads to a non-optimal output SINR and too small a step size leads to slow convergence speed. FPGA implementation demonstrations are implemented and tested on a NI FPGA module, and test results demonstrate good real-time performance and low slice resource consumption.

12.
Sensors (Basel) ; 24(17)2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39275717

RESUMEN

To detect damage in mechanical structures, acoustic emission (AE) inspection is considered as a powerful tool. Generally, the classical acoustic emission detection method uses a sparse sensor array to identify damage and its location. It often depends on a pre-defined wave velocity and it is difficult to yield a high localization accuracy for complicated structures using this method. In this paper, the passive guided wave phased array method, a dense sensor array method, is studied, aiming to obtain better AE localization accuracy in aluminum thin plates. Specifically, the proposed method uses a cross-shaped phased array enhanced with four additional far-end sensors for AE source localization. The proposed two-step method first calculates the real-time velocity and the polar angle of the AE source using the phased array algorithm, and then solves the location of the AE source with the additional far-end sensor. Both numerical and physical experiments on an aluminum flat panel are carried out to validate the proposed method. It is found that using the cross-shaped guided wave phased array method with enhanced far-end sensors can localize the coordinates of the AE source accurately without knowing the wave velocity in advance. The proposed method is also extended to a stiffened thin-walled structure with high localization accuracy, which validates its AE source localization ability for complicated structures. Finally, the influences of cross-shaped phased array element number and the time window length on the proposed method are discussed in detail.

13.
Sensors (Basel) ; 24(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38474957

RESUMEN

This paper presents a novel approach for preload measurement of bolted connections, specifically tailored for offshore wind applications. The proposed method combines robotics, Phased Array Ultrasonic Testing (PAUT), nonlinear acoustoelasticity, and Finite Element Analysis (FEA). Acceptable defects, below a pre-defined size, are shown to have an impact on preload measurement, and therefore conducting simultaneous defect detection and preload measurement is discussed in this paper. The study demonstrates that even slight changes in the orientation of the ultrasonic transducer, the non-automated approach, can introduce a significant error of up to 140 MPa in bolt stress measurement and therefore a robotic approach is employed to achieve consistent and accurate measurements. Additionally, the study emphasises the significance of considering average preload for comparison with ultrasonic data, which is achieved through FEA simulations. The advantages of the proposed robotic PAUT method over single-element approaches are discussed, including the incorporation of nonlinearity, simultaneous defect detection and stress measurement, hardware and software adaptability, and notably, a substantial improvement in measurement accuracy. Based on the findings, the paper strongly recommends the adoption of the robotic PAUT approach for preload measurement, whilst acknowledging the required investment in hardware, software, and skilled personnel.

14.
Nano Lett ; 23(9): 3866-3871, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37093959

RESUMEN

Far-field optical beam steering is a fast-growing technology for communications, spatial ranging, and detections. Nonmechanical optical phased arrays based on straight waveguides have been studied recently, where the beam emission angle to the propagation axis can be scanned by conveniently tuning the wavelength. However, the dispersion of the waveguide limits the wavelength sensitivity of beam steering and the deliberately created emitters inevitably introduce in-line backscattering on-chip. To overcome these limitations, here, we report a robust and back-reflection-free topological photonic integrated circuit, where different functionalities, such as beam splitting, routing, and far-field steering, are defined by strategic arrangements of lattices with different topological modulations simply controlled by a single lattice deformation parameter. Benefiting from the robust topological scheme, an extra band flattening is applied to achieve far-field steering with high wavelength sensitivity.

15.
Magn Reson Med ; 90(6): 2592-2607, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37582214

RESUMEN

PURPOSE: A 128-channel receive-only array for brain imaging at 7 T was simulated, designed, constructed, and tested within a high-performance head gradient designed for high-resolution functional imaging. METHODS: The coil used a tight-fitting helmet geometry populated with 128 loop elements and preamplifiers to fit into a 39 cm diameter space inside a built-in gradient. The signal-to-noise ratio (SNR) and parallel imaging performance (1/g) were measured in vivo and simulated using electromagnetic modeling. The histogram of 1/g factors was analyzed to assess the range of performance. The array's performance was compared to the industry-standard 32-channel receive array and a 64-channel research array. RESULTS: It was possible to construct the 128-channel array with body noise-dominated loops producing an average noise correlation of 5.4%. Measurements showed increased sensitivity compared with the 32-channel and 64-channel array through a combination of higher intrinsic SNR and g-factor improvements. For unaccelerated imaging, the 128-channel array showed SNR gains of 17.6% and 9.3% compared to the 32-channel and 64-channel array, respectively, at the center of the brain and 42% and 18% higher SNR in the peripheral brain regions including the cortex. For R = 5 accelerated imaging, these gains were 44.2% and 24.3% at the brain center and 86.7% and 48.7% in the cortex. The 1/g-factor histograms show both an improved mean and a tighter distribution by increasing the channel count, with both effects becoming more pronounced at higher accelerations. CONCLUSION: The experimental results confirm that increasing the channel count to 128 channels is beneficial for 7T brain imaging, both for increasing SNR in peripheral brain regions and for accelerated imaging.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Relación Señal-Ruido , Fantasmas de Imagen , Neuroimagen/métodos , Diseño de Equipo
16.
Sensors (Basel) ; 23(15)2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37571609

RESUMEN

This paper presents a wideband 4-bit true time delay IC using a 0.25 µm GaN HEMT (High-Electron-Mobility Transistor) process for the beam-squint-free phased array antennas. The true time delay IC is implemented with a switched path circuit topology using DPDT (Double Pole Double Throw) with no shunt transistor in the inter-stages to improve the bandwidth and SPDT (Single Pole Single Throw) switches at the input and the output ports. The delay lines are implemented with CLC π-networks with the lumped element to ensure a compact chip size. A negative voltage generator and an SPI controller are implemented in the PCB (Printed Circuit Board) due to the lack of digital control logic in GaN technology. A maximum time delay of ~182 ps with a time delay resolution of 10.5 ps is achieved at DC-6 GHz. The RMS (Root Mean Square) time delay and amplitude error are <5 ps and <0.6 dB, respectively. The measured insertion loss is <6.8 dB and the input and output return losses are >10 dB at DC-6 GHz. The current consumption is nearly zero with a 3.3 V supply. The chip size including pads is 2.45 × 1.75 mm2. To the authors' knowledge, this is the first demonstration of a true time delay IC using GaN HEMT technology.

17.
Sensors (Basel) ; 23(6)2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36991922

RESUMEN

Adaptive array processing technology for a phased array radar is usually based on the assumption of a stationary environment; however, in real-world scenarios, nonstationary interference and noise deteriorate the performance of the traditional gradient descent algorithm, in which the learning rate of the tap weights is fixed, leading to errors in the beam pattern and a reduced output signal-to-noise ratio (SNR). In this paper, we use the incremental delta-bar-delta (IDBD) algorithm, which has been widely used for system identification problems in nonstationary environments, to control the time-varying learning rates of the tap weights. The designed iteration formula for the learning rate ensures that the tap weights adaptively track the Wiener solution. The results of numerical simulations show that in a nonstationary environment, the traditional gradient descent algorithm with a fixed learning rate has a distorted beam pattern and reduced output SNR; however, the IDBD-based beamforming algorithm, in which a secondary control mechanism is used to adaptively update the learning rates, showed a similar beam pattern and output SNR to a traditional beamformer in a Gaussian white noise background; that is, the main beam and null satisfied the pointing constraints, and the optimal output SNR was obtained. Although the proposed algorithm contains a matrix inversion operation, which has considerable computational complexity, this operation could be replaced by the Levinson-Durbin iteration due to the Toeplitz characteristic of the matrix; therefore, the computational complexity could be decreased to O(n), so additional computing resources are not required. Moreover, according to some intuitive interpretations, the reliability and stability of the algorithm are guaranteed.

18.
Sensors (Basel) ; 23(2)2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36679531

RESUMEN

A very compact waveguide orthomode transducer (OMT) is described in this paper. The design is characterized with a twofold rotationally symmetric cross-section in the probing area, adapted from a side-coupling OMT design, simultaneously enabling low port-to-port coupling and high cross-polarization discrimination (XPD) over a fractional bandwidth of about 15-20%. Compared to previously reported compact waveguide OMTs, the proposed design is simpler, thus facilitating its manufacture at millimeter-wave frequencies. The concept is demonstrated with a design in the K-band for a broadband communication satellite downlink over the frequency band of 17.3-20.2 GHz. For test purposes, transitions to standard waveguide WR42 are included, and the OMT is assembled with a conical horn antenna. The measured reflection and coupling coefficients are below -19.5 dB and -22.9 dB, respectively, over the nominal bandwidth, and they are in good agreement with the simulation's results. The on-axis XPD, measured in an anechoic chamber, is better than 30 dB over the nominal bandwidth, which is also in line with simulations. The proposed waveguide OMT may be designed to fit in a lattice below one wavelength at the highest operating frequency, which is desirable for dual-polarized closely spaced array antennas in low and medium Earth orbit communication satellite systems. The simple mechanical design of the proposed OMT makes it particularly appealing for additive manufacturing techniques, as demonstrated with a variant of the design having folded single-mode waveguides, which preserves the RF properties of the original design.


Asunto(s)
Comercio , Refracción Ocular , Comunicaciones por Satélite , Transductores
19.
Sensors (Basel) ; 23(6)2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36991801

RESUMEN

A compact and planar imaging system was developed using a flexible polymer substrate that can distinguish subcutaneous tissue abnormalities, such as breast tumors, based on electromagnetic-wave interactions in materials where permittivity variations affect wave reflection. The sensing element is a tuned loop resonator operating in the industrial, scientific, and medical (ISM) band at 2.423 GHz, providing a localized high-intensity electric field that penetrates into tissues with sufficient spatial and spectral resolutions. The resonant frequency shifts and magnitudes of the reflection coefficients indicate the boundaries of abnormal tissues under the skin due to their high contrasts to normal tissues. The sensor was tuned to the desired resonant frequency with a reflection coefficient of -68.8 dB for a radius of 5.7 mm, with a tuning pad. Quality factors of 173.1 and 34.4 were achieved in simulations and measurements in phantoms. An image-processing method was introduced to fuse raster-scanned 9 × 9 images of resonant frequencies and reflection coefficients for image-contrast enhancement. The results showed a clear indication of the tumor's location at a depth of 15 mm and the capability to identify two tumors both at the depth of 10 mm. The sensing element can be expanded to a four-element phased array for deeper field penetration. Field analysis showed the depths of -20 dB attenuation were improved from 19 to 42 mm, giving wider coverage in tissues at resonance. Results showed that a quality factor of 152.5 was achieved and a tumor could be identified at a depth of up to 50 mm. In this work, simulations and measurements were conducted to validate the concept, showing great potential for subcutaneous imaging in medical applications in a noninvasive, efficient, and lower-cost way.


Asunto(s)
Microondas , Neoplasias , Humanos , Tejido Subcutáneo/diagnóstico por imagen , Diseño de Equipo , Aumento de la Imagen
20.
Sensors (Basel) ; 23(4)2023 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-36850375

RESUMEN

The ultrasonic detectability of buried defects within composite materials is dependent on the anisotropy of the composite material by which the propagation property of acoustic wave in each direction is variably affected. In this study, the characteristics of acoustic waves propagating in different directions for composite materials are explored based on the full matrix capture (FMC) data using an ultrasonic phased array. The elastic constant of multidirectional carbon fiber reinforced plastic (CFRP) laminate is first derived based on the genetic algorithm. The characteristics of transmitted and reflected waves in higher angles are predicted by implementing the Christoffel equation, and the focal law used in post-processing of FMC data can be optimized accordingly. The imaging results of the total focusing method (TFM) using the improved focal law are compared with the results of the conventional TFM. The results suggest that the optimized TFM can effectively characterize the defect by reducing the background noise. Furthermore, since it is impractical to theoretically correct angle-dependent velocity for in situ inspection, a linear extrapolation method based on the experimentally measurable velocity at low angles is proposed to estimate the velocity profile at higher angles. The imaging results using the fast extrapolated velocity profile is then compared with the theoretical, and it has been demonstrated that while the difference between the images using the theoretical focal law and the linearly extrapolated one is barely visible, the later one is overwhelmingly advantageous to be realiszd for engineering practices.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda