Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 7.183
Filtrar
Más filtros

Publication year range
1.
Hepatology ; 80(4): 887-900, 2024 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-38447034

RESUMEN

BACKGROUND AND AIMS: Compensated advanced chronic liver disease (cACLD) identifies patients at risk for clinically significant portal hypertension (CSPH), and thus, for liver-related complications. The limited availability of liver stiffness measurements (LSM) impedes the identification of patients at risk for cACLD/CSPH outside of specialized clinics. We aimed to develop a blood-based algorithm to identify cACLD by fibrosis-4 (FIB-4) and CSPH by von Willebrand factor/platelet count ratio (VITRO). APPROACH AND RESULTS: Patients with (suspected) compensated chronic liver disease undergoing FIB-4+LSM were included in the LSM/FIB-4 cohorts from Vienna and Salzburg. The HVPG/VITRO cohorts included patients undergoing HVPG-measurement + VITRO from Vienna and Bern.LSM/FIB-4-derivation-cohort: We included 6143 patients, of whom 211 (3.4%) developed hepatic decompensation. In all, 1724 (28.1%) had LSM ≥ 10 kPa, which corresponded to FIB-4 ≥ 1.75. Importantly, both LSM (AUROC:0.897 [95% CI:0.865-0.929]) and FIB-4 (AUROC:0.914 [95% CI:0.885-0.944]) were similarly accurate in predicting hepatic decompensation within 3 years. FIB-4 ≥ 1.75 identified patients at risk for first hepatic decompensation (5 y-cumulative incidence:7.6%), while in those <1.75, the risk was negligible (0.3%).HVPG/VITRO-derivation cohort: 247 patients of whom 202 had cACLD/FIB-4 ≥ 1.75 were included. VITRO exhibited an excellent diagnostic performance for CSPH (AUROC:0.889 [95% CI:0.844-0.934]), similar to LSM (AUROC:0.856 [95% CI:0.801-0.910], p = 0.351) and the ANTICIPATE model (AUROC:0.910 [95% CI:0.869-0.952], p = 0.498). VITRO < 1.0/ ≥ 2.5 ruled-out (sensitivity:100.0%)/ruled-in (specificity:92.4%) CSPH. The diagnostic performance was comparable to the Baveno-VII criteria.LSM/FIB-4-derivation cohort findings were externally validated in n = 1560 patients, while HVPG/VITRO-derivation-cohort findings were internally (n = 133) and externally (n = 55) validated. CONCLUSIONS: Simple, broadly available laboratory tests (FIB-4/VITRO) facilitate cACLD detection and CSPH risk stratification in patients with (suspected) liver disease. This blood-based approach is applicable outside of specialized clinics and may promote early intervention.


Asunto(s)
Hipertensión Portal , Humanos , Hipertensión Portal/diagnóstico , Hipertensión Portal/sangre , Hipertensión Portal/etiología , Femenino , Persona de Mediana Edad , Masculino , Medición de Riesgo/métodos , Anciano , Diagnóstico por Imagen de Elasticidad/métodos , Recuento de Plaquetas , Algoritmos , Enfermedad Crónica , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/sangre , Cirrosis Hepática/complicaciones , Factor de von Willebrand/análisis , Factor de von Willebrand/metabolismo , Adulto , Hepatopatías/diagnóstico , Hepatopatías/sangre , Pruebas Hematológicas/métodos , Estudios de Cohortes
2.
Hepatology ; 79(5): 1098-1106, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862551

RESUMEN

BACKGROUND AND AIMS: Recently, the American Gastroenterological Association and the American Association for the Study of Liver Diseases developed clinical pathways to evaluate populations at high risk for NAFLD. We assessed the diagnostic performance of the new guidance in a well-phenotyped cohort of patients with Type 2 diabetes mellitus (T2DM). APPROACH AND RESULTS: This prospective study enrolled patients age ≥50 years with T2DM. Participants underwent a standardized clinical research visit with MRI and ultrasound-based assessment of liver fat and stiffness and Enhanced Liver Fibrosis (ELF) testing. Of 417 participants (36% men) with T2DM with FIB-4 and MRE data, the prevalence of NAFLD was 64% and 12% had advanced fibrosis (MRE≥3.63 kPa). Applying the American Gastroenterological Association pathway of FIB-4 and vibration-controlled transient elastography, the false negative rate was 3.3% and 18% would qualify for specialty referral. Applying the FIB-4 + ELF American Association for the Study of Liver Diseases pathway, the false negative rate was 4.5%, but 50% would qualify for specialty referral. Applying higher ELF cut points improved the pathway, yielding a similar false negative rate of 4.9% but decreased specialty referral to 27%. CONCLUSION: Validation of the American Gastroenterological Association clinical pathway in a prospectively recruited cohort with T2DM revealed a low false negative rate and avoided specialty referral in a large percentage of patients. The American Association for the Study of Liver Diseases pathway with FIB-4 + ELF resulted in a high rate of specialty referral, which improved with the utilization of higher ELF cut points and may serve as an alternative for primary care and endocrinology clinics without access to vibration-controlled transient elastography.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Masculino , Humanos , Persona de Mediana Edad , Femenino , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Enfermedad del Hígado Graso no Alcohólico/terapia , Estudios Prospectivos , Vías Clínicas , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/terapia , Diabetes Mellitus Tipo 2/epidemiología , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/complicaciones , Diagnóstico por Imagen de Elasticidad/métodos
3.
Semin Liver Dis ; 44(1): 23-34, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38262447

RESUMEN

More than one-third of the adult world population has steatotic liver disease (SLD), with a few percent of individuals developing cirrhosis after decades of silent liver fibrosis accumulation. Lack of systematic early detection causes most patients to be diagnosed late, after decompensation, when treatment has limited effect and survival is poor. Unfortunately, no isolated screening test in primary care can sufficiently predict advanced fibrosis from SLD. Recent efforts, therefore, combine several parameters into screening algorithms, to increase diagnostic accuracy. Besides patient selection, for example, by specific characteristics, algorithms include nonpatented or patented blood tests and liver stiffness measurements using elastography-based techniques. Algorithms can be composed as a set of sequential tests, as recommended by most guidelines on primary care pathways. Future use of algorithms that are easy to interpret, cheap, and semiautomatic will improve the management of patients with SLD, to the benefit of global health care systems.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hígado Graso , Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Cirrosis Hepática/diagnóstico por imagen , Hígado Graso/patología , Algoritmos , Atención Primaria de Salud , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/patología , Hígado/patología
4.
Neuroimage ; 295: 120662, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38823503

RESUMEN

Understanding the physiological processes in aging and how neurodegenerative disorders affect cognitive function is a high priority for advancing human health. One specific area of recently enabled research is the in vivo biomechanical state of the brain. This study utilized reverberant optical coherence elastography, a high-resolution elasticity imaging method, to investigate stiffness changes during the sleep/wake cycle, aging, and Alzheimer's disease in murine models. Four-dimensional scans of 44 wildtype mice, 13 mice with deletion of aquaporin-4 water channel, and 12 mice with Alzheimer-related pathology (APP/PS1) demonstrated that (1) cortical tissue became softer (on the order of a 10% decrease in shear wave speed) when young wildtype mice transitioned from wake to anesthetized, yet this effect was lost in aging and with mice overexpressing amyloid-ß or lacking the water channel AQP4. (2) Cortical stiffness increased with age in all mice lines, but wildtype mice exhibited the most prominent changes as a function of aging. The study provides novel insight into the brain's biomechanics, the constraints of fluid flow, and how the state of brain activity affects basic properties of cortical tissues.


Asunto(s)
Envejecimiento , Enfermedad de Alzheimer , Encéfalo , Diagnóstico por Imagen de Elasticidad , Sueño , Animales , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/fisiopatología , Envejecimiento/fisiología , Diagnóstico por Imagen de Elasticidad/métodos , Ratones , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Sueño/fisiología , Vigilia/fisiología , Ratones Transgénicos , Acuaporina 4/metabolismo , Acuaporina 4/genética , Masculino , Ratones Endogámicos C57BL
5.
J Hepatol ; 81(5): 772-780, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38879175

RESUMEN

BACKGROUND & AIMS: Non-invasive tests (NITs) for liver fibrosis have been recognized for their clinical utility in metabolic dysfunction-associated steatotic liver disease (MASLD). However, their diagnostic efficacy in detecting liver fibrosis is notably reduced in patients with alcohol-related liver disease. Therefore, ascertaining the reliability of NITs in patients with MASLD with moderate alcohol intake (MetALD) is essential. METHODS: In this cross-sectional study, we reviewed data from 7,918 health check-up participants who underwent both magnetic resonance elastography (MRE) and ultrasound for the diagnosis of hepatic steatosis. The participants were categorized into MASLD and MetALD groups, and the performance of fibrosis-4 index (FIB-4) and NAFLD fibrosis score (NFS) were assessed. Advanced hepatic fibrosis (F3) was defined as MRE ≥3.6 kPa. RESULTS: The prevalence of MetALD was 5.8% in this health check-up cohort, and 1.5% of these patients exhibited advanced hepatic fibrosis. Both MetALD and MASLD displayed similar metabolic profiles and hepatic fibrosis burdens. The diagnostic performance of FIB-4 and NFS for MRE ≥3.6 kPa showed no noticeable differences in the area under the receiver-operating characteristic values between the two groups (0.85 vs. 0.80 in FIB-4). Moreover, the sensitivity (71.4%), specificity (77.3%), and both positive (4.6%) and negative (99.4%) predictive values of NITs for MetALD closely mirrored those observed for MASLD. CONCLUSION: FIB-4 performed well for the initial screening of advanced hepatic fibrosis in MetALD, demonstrating reasonable sensitivity and negative predictive values. IMPACT AND IMPLICATIONS: In this cross-sectional study, data from 7,918 participants who underwent MRE were analyzed to assess the performance of fibrosis-4 (FIB-4) and non-alcoholic fatty liver disease fibrosis scores in metabolic dysfunction-associated steatotic liver disease (MASLD) and MASLD with moderate alcohol intake (MetALD). We found that FIB-4 had high diagnostic accuracy in the newly identified MetALD group, similar to that in the MASLD population. These results highlight the potential of FIB-4 as a reliable screening tool for MetALD, even when specific subgroups are considered. Therefore, FIB-4 is a valuable screening tool for identifying advanced fibrosis in the MetALD population.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Humanos , Masculino , Femenino , Persona de Mediana Edad , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Transversales , Cirrosis Hepática/diagnóstico , Adulto , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Ultrasonografía/métodos , Estudios de Cohortes , Anciano , Reproducibilidad de los Resultados , Hígado Graso/diagnóstico , Consumo de Bebidas Alcohólicas/efectos adversos , Curva ROC
6.
J Hepatol ; 81(4): 600-608, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38762169

RESUMEN

BACKGROUND & AIMS: The clinical significance of change in liver stiffness measurement (LSM) by vibration-controlled transient elastography (VCTE) in patients with non-alcoholic fatty liver disease (NAFLD) is not well-understood. We prospectively defined rates of progression to and regression from LSM-defined compensated advanced chronic liver disease (cACLD) and their associations with liver-related events (LREs). METHODS: Participants in the NASH Clinical Research Network-led NAFLD Database 2 and 3 studies were included. Progression to cACLD was defined as reaching LSM ≥10 kPa in participants with LSM <10 kPa on initial VCTE; regression from cACLD was defined as reaching LSM <10 kPa in participants with baseline LSM ≥10 kPa. LREs were defined as liver-related death, liver transplant, hepatocellular carcinoma, MELD >15, development of varices, or hepatic decompensation. Univariate and multivariable interval-censored Cox regression analyses were used to compare the cumulative LRE probability by LSM progression and regression status. RESULTS: In 1,403 participants, 89 LREs developed over a mean follow-up of 4.4 years, with an annual incidence rate for LREs of 1.5 (95% CI 1.2-1.8). In participants at risk, progression to LSM ≥10 or ≥15 kPa occurred in 29% and 17%, respectively, whereas regression to LSM <10 or <15 kPa occurred in 44% and 49%, respectively. Progressors to cACLD (≥10 kPa) experienced a higher cumulative LRE rate vs. non-progressors (16% vs. 4%, adjusted hazard ratio 4.0; 95% (1.8-8.9); p <0.01). Regressors from cACLD (to LSM <10 kPa) experienced a lower LRE rate than non-regressors (7% vs. 32%, adjusted hazard ratio 0.25; 95% CI 0.10-0.61; p <0.01). CONCLUSIONS: Change in LSM over time is independently and bi-directionally associated with risk of LRE and is a non-invasive surrogate for clinical outcomes in patients with NAFLD. IMPACT AND IMPLICATIONS: The prognostic value of change in LSM in patients with NAFLD is not well understood. In this large prospective study of patients with NAFLD and serial vibration-controlled transient elastography exams, baseline and dynamic changes in LSM were associated with the risk of developing liver-related events. LSM is a useful non-invasive surrogate of clinical outcomes in patients with NAFLD.


Asunto(s)
Progresión de la Enfermedad , Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/fisiopatología , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Hígado/diagnóstico por imagen , Hígado/fisiopatología , Hígado/patología , Adulto , Factores de Riesgo , Anciano
7.
J Hepatol ; 81(1): 23-32, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38428644

RESUMEN

BACKGROUND & AIMS: Liver stiffness measurement (LSM) is recommended for disease prognostication and monitoring. We evaluated if LSM, using transient elastography, and LSM changes predict decompensation and mortality in patients with alcohol-related liver disease (ALD). METHODS: We performed an observational cohort study of compensated patients at risk of ALD from Denmark and Austria. We evaluated the risk of decompensation and all-cause mortality, stratified for compensated advanced chronic liver disease (cACLD: baseline LSM ≥10 kPa) and LSM changes after a median of 2 years. In patients with cACLD, we defined LSM changes as (A) LSM increase ≥20% ("cACLD increasers") and (B) follow-up LSM <10 kPa or <20 kPa with LSM decrease ≥20% ("cACLD decreasers"). In patients without cACLD, we defined follow-up LSM ≥10 kPa as an LSM increase ("No cACLD increasers"). The remaining patients were considered LSM stable. RESULTS: We followed 536 patients for 3,008 patient-years-median age 57 years (IQR 49-63), baseline LSM 8.1 kPa (IQR 4.9-21.7)-371 patients (69%) had follow-up LSM after a median of 25 months (IQR 17-38), 41 subsequently decompensated and 55 died. Of 125 with cACLD at baseline, 14% were "cACLD increasers" and 43% "cACLD decreasers", while 13% of patients without cACLD were "No cACLD increasers" (n = 33/246). Baseline LSM, follow-up LSM and LSM changes accurately predicted decompensation (C-index: baseline LSM 0.85; follow-up LSM 0.89; LSM changes 0.85) and mortality (C-index: baseline LSM 0.74; follow-up LSM 0.74; LSM changes 0.70). When compared to "cACLD decreasers", "cACLD increasers" had significantly lower decompensation-free survival and higher risks of decompensation (subdistribution hazard ratio 4.39, p = 0.004) and mortality (hazard ratio 3.22, p = 0.01). CONCLUSION: LSM by transient elastography predicts decompensation and all-cause mortality in patients with compensated ALD both at diagnosis and when used for monitoring. IMPACT AND IMPLICATIONS: Patients at risk of alcohol-related liver disease (ALD) are at significant risk of progressive disease and adverse outcomes. Monitoring is essential for optimal disease surveillance and patient guidance, but non-invasive monitoring tools are lacking. In this study we demonstrate that liver stiffness measurement (LSM), using transient elastography, and LSM changes after a median of 2 years, can predict decompensation and all-cause mortality in patients at risk of ALD with and without compensated advanced chronic liver disease. These findings are in line with results from non-alcoholic fatty liver disease, hepatitis C and primary sclerosing cholangitis, and support the clinical utility of LSM, using transient elastography, for disease prognostication and monitoring in chronic liver diseases including ALD, as recommended by the Baveno VII.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatopatías Alcohólicas , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Persona de Mediana Edad , Masculino , Femenino , Hepatopatías Alcohólicas/mortalidad , Hepatopatías Alcohólicas/complicaciones , Dinamarca/epidemiología , Austria/epidemiología , Pronóstico , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/fisiopatología , Estudios de Cohortes , Valor Predictivo de las Pruebas
8.
J Hepatol ; 81(4): 590-599, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38789011

RESUMEN

BACKGROUND & AIMS: Agile scores, including liver stiffness measurements (LSM) and routine clinical/laboratory biomarkers, have been developed for advanced fibrosis (F≥3) and cirrhosis (F4), respectively, in patients with metabolic dysfunction-associated steatotic liver disease (MASLD). We independently validated the diagnostic accuracy of these scores in MASLD, alcohol-related liver disease (ALD) and chronic hepatitis B or C (CHB/C) and assessed them in clinical algorithms with FIB-4 and LSM. METHODS: We included 4,243 patients (MASLD: 912, ALD: 386, CHB: 597, CHC: 2,348) with LSM, liver biopsy and laboratory tests within 6 months. FIB-4, Agile 3+ and Agile 4 scores were calculated. RESULTS: For F≥3, the diagnostic accuracy of Agile 3+ and LSM were similar in MASLD (AUC: 0.86 vs. 0.86, p = 0.831) and ALD (0.92 vs. 0.94, p = 0.123). For cirrhosis, Agile 4 was similar to LSM in MASLD (0.89 vs. 0.90, p = 0.412) and ALD (0.94 vs. 0.95, p = 0.513). Agile 3+/4 performed worse than LSM in CHB/C. Using predefined dual thresholds of 90% sensitivity/specificity, correct classification rates in MASLD were 66% vs. 61% using Agile 3+ vs. LS dual cut-offs and 71% vs. 67% in ALD, respectively. When using Agile 3+ or LSM as a second step after FIB-4 >1.3, correct classification rates were higher with Agile 3+ than LSM, both for MASLD (75% vs. 71%) and ALD (76% vs. 72%), with fewer indeterminate results. Positive agreement of LSM and Agile 3+/4 significantly increased the specificity of a diagnosis of advanced fibrosis/cirrhosis. CONCLUSION: Agile 3+ and Agile 4 have equal diagnostic accuracy with LSM in both MASLD and ALD but result in fewer indeterminate results. Sequential use of FIB-4 and Agile 3+/4 or concurrent Agile 3+/4 and LSM can be used to further optimize F≥3 diagnosis. IMPACT AND IMPLICATIONS: As of today, it is accepted that there will be no single non-invasive test or an isolated cut-off for identifying patients with advanced chronic liver disease. Here, we confirmed that Agile 3+ and Agile 4 scores are useful alternatives to simple liver stiffness measurement in diagnosing advanced fibrosis/cirrhosis in steatotic liver disease, but they do not perform as well in chronic viral hepatitis. Agile scores can help optimize the diagnosis of advanced fibrosis/cirrhosis in a dual cut-off strategy by reducing the number of indeterminate results either alone or in a sequential strategy after FIB-4. The combination of Agile scores and liver stiffness measurement can further increase our confidence in a positive diagnosis of advanced fibrosis/cirrhosis. These novel combination strategies can be useful tools to predict the likelihood of advanced stages of liver disease with the highest possible accuracy in a secondary/tertiary healthcare setting.


Asunto(s)
Algoritmos , Cirrosis Hepática , Humanos , Femenino , Masculino , Persona de Mediana Edad , Cirrosis Hepática/diagnóstico , Adulto , Hígado Graso/diagnóstico , Hígado Graso/patología , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/diagnóstico , Biomarcadores/análisis , Diagnóstico por Imagen de Elasticidad/métodos , Hepatopatías Alcohólicas/diagnóstico , Hepatopatías Alcohólicas/complicaciones , Hepatopatías Alcohólicas/patología , Hígado/patología , Hígado/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Hepatitis C Crónica/complicaciones , Hepatitis C Crónica/diagnóstico , Biopsia/métodos
9.
J Hepatol ; 81(2): 195-206, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38548067

RESUMEN

BACKGROUND & AIMS: Non-invasive scores have been proposed to identify patients with fibrotic, metabolic dysfunction-associated steatohepatitis (MASH), who are at the highest risk of progression to complications of cirrhosis and may benefit from pharmacologic treatments. However, data in patients with type 2 diabetes (T2DM) are lacking. The aim of this multicenter prospective study was to perform a head-to-head comparison of FAST (FibroScan-aspartate aminotransferase [AST]), MAST (MRI-AST), MEFIB (magnetic resonance elastography [MRE] plus FIB-4), and FNI (fibrotic NASH index) for detecting fibrotic MASH in patients with T2DM. METHODS: A total of 330 outpatients with T2DM and biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD) from the QUID-NASH study (NCT03634098), who underwent FibroScan, MRI-proton density fat fraction and MRE at the time of liver biopsy were studied. The main outcome was fibrotic MASH, defined as NAS ≥4 (with at least one point for each parameter) and fibrosis stage ≥2 (centrally reviewed). RESULTS: All data for score comparisons were available for 245 patients (median age 59 years, 65% male, median BMI 31 kg/m2; fibrotic MASH in 39%). FAST and MAST had similar accuracy (AUROCs 0.81 vs. 0.79, p = 0.41) but outperformed FNI (0.74; p = 0.01) and MEFIB (0.68; p <0.0001). When using original cut-offs, MAST outperformed FAST, MEFIB and FNI when comparing the percentage of correctly classified patients, in whom liver biopsy would be avoided (69% vs. 48%, 46%, 39%, respectively; p <0.001). When using cut-offs specific to our population, FAST outperformed FNI and MAST (56% vs. 40%, and 38%, respectively; p <0.001). CONCLUSION: Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. IMPACT AND IMPLICATIONS: Among patients with type 2 diabetes (T2DM), identifying those with metabolic dysfunction-associated steatohepatitis and significant fibrosis, who are the most at risk of developing clinical liver-related outcomes and who may benefit from pharmacologic treatments, is an unmet need. In this prospective multicenter study, we compared four non-invasive scores, three based on imaging (MRI or ultrasound technologies) and one on laboratory blood tests, for this purpose, using original and study-specific cut-offs. Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. TRIAL REGISTRATION NUMBER: NCT03634098.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Imagen por Resonancia Magnética , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Masculino , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/etiología , Imagen por Resonancia Magnética/métodos , Anciano , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Biopsia/métodos , Hígado/patología , Hígado/diagnóstico por imagen , Aspartato Aminotransferasas/sangre
10.
J Hepatol ; 81(2): 248-257, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38479612

RESUMEN

BACKGROUND & AIMS: Non-invasive tests (NITs) for clinically significant portal hypertension (CSPH) require validation in patients with hepatitis D virus (HDV)-related compensated advanced chronic liver disease (cACLD). Therefore, we aimed to validate existing NIT algorithms for CSPH in this context. METHODS: Patients with HDV-cACLD (LSM ≥10 kPa or histological METAVIR F3/F4 fibrosis) who underwent paired HVPG and NIT assessment at Medical University of Vienna or Hannover Medical School between 2013 and 2023 were retrospectively included. Liver stiffness measurement (LSM), von Willebrand factor to platelet count ratio (VITRO), and spleen stiffness measurement (SSM) were assessed. Individual CSPH risk was calculated according to previously published models (ANTICIPATE, 3P/5P). The diagnostic performance of Baveno VII criteria and refined algorithms (Baveno VII-VITRO, Baveno VII-SSM) was evaluated. The prognostic utility of NITs was investigated in the main cohort and an independent, multicenter, validation cohort. RESULTS: Fifty-one patients (HVPG ≥10 mmHg/CSPH prevalence: 62.7%, varices: 42.2%) were included. Patients with CSPH had significantly higher LSM (25.8 [17.2-31.0] vs. 14.0 [10.5-19.8] kPa; p <0.001), VITRO (n = 31, 3.5 [2.7-4.5] vs. 1.3 [0.6-2.0] %/[G/L]; p <0.001), and SSM (n = 20, 53.8 [41.7-75.5] vs. 24.0 [17.0-33.9] kPa; p <0.001). Composite CSPH risk models yielded excellent AUROCs (ANTICIPATE: 0.885, 3P: 0.903, 5P: 0.912). Baveno VII criteria ruled out CSPH with 100% sensitivity and ruled in CSPH with 84.2% specificity. The Baveno VII 'grey zone' (41.1%) was significantly reduced by Baveno VII-VITRO or Baveno VII-SSM algorithms, which maintained diagnostic accuracy. Hepatic decompensation within 2 years only occurred in patients who had CSPH or met Baveno VII rule-in criteria. The prognostic value of NITs was confirmed in the validation cohort comprising 92 patients. CONCLUSIONS: Standalone and composite NIT/diagnostic algorithms are useful for CSPH diagnosis in patients with HDV-cACLD. Thus, NITs may be applied to identify and prioritize patients with CSPH for novel antiviral treatments against chronic hepatitis D. IMPACT AND IMPLICATIONS: Non-invasive tests (NITs) for clinically significant portal hypertension (CSPH) have been developed to identify patients with compensated advanced chronic liver disease (cACLD) at risk of decompensation, but conflicting data has been published regarding the accuracy of liver stiffness measurement (LSM) for the staging of fibrosis in patients infected with hepatitis D virus (HDV). In our study, including 51 patients with HDV-cACLD, LSM- and lab-based NITs yielded high AUROCs for CSPH. Moreover, only patients with CSPH or high non-invasively assessed CSPH risk were at risk of decompensation within 2 years, with the prognostic value of NITs confirmed in a validation cohort. Thus, NITs should be applied and updated in yearly intervals in clinical routine to identify patients with HDV-cACLD at short-term risk of clinical events; NITs may also guide prioritization for novel antiviral treatment options.


Asunto(s)
Algoritmos , Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Humanos , Hipertensión Portal/diagnóstico , Hipertensión Portal/etiología , Hipertensión Portal/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Adulto , Hígado/diagnóstico por imagen , Hígado/patología , Hepatitis D/diagnóstico , Hepatitis D/complicaciones , Virus de la Hepatitis Delta/aislamiento & purificación , Recuento de Plaquetas , Pronóstico , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/complicaciones , Cirrosis Hepática/virología , Factor de von Willebrand/análisis , Factor de von Willebrand/metabolismo
11.
J Hepatol ; 81(1): 76-83, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38521170

RESUMEN

BACKGROUND & AIMS: Baveno VII has defined a clinically significant (i.e., prognostically meaningful) decrease in liver stiffness measurement (LSM) in cACLD as a decrease of ≥20% associated with a final LSM <20 kPa or any decrease to <10 kPa. However, these rules have not yet been validated against direct clinical endpoints. METHODS: We retrospectively analysed patients with cACLD (LSM ≥10 kPa) with paired liver stiffness measurement (LSM) before (BL) and after (FU) HCV cure by interferon-free therapies from 15 European centres. The cumulative incidence of hepatic decompensation was compared according to these criteria, considering hepatocellular carcinoma and non-liver-related death as competing risks. RESULTS: A total of 2,335 patients followed for a median of 6 years were analysed. Median BL-LSM was 16.6 kPa with 37.1% having ≥20 kPa. After HCV cure, FU-LSM decreased to a median of 10.9 kPa (<10 kPa: 1,002 [42.9%], ≥20 kPa: 465 [19.9%]) translating into a median LSM change of -5.3 (-8.8 to -2.4) kPa corresponding to -33.9 (-48.0 to -15.9) %. Patients achieving a clinically significant decrease (65.4%) had a significantly lower risk of hepatic decompensation (subdistribution hazard ratio: 0.12, 95% CI 0.04-0.35, p <0.001). However, these risk differences were primarily driven by a negligible risk in patients with FU-LSM <10 kPa (5-year cumulative incidence: 0.3%) compared to a high risk in patients with FU-LSM ≥20 kPa (16.6%). Patients with FU-LSM 10-19.9 kPa (37.4%) also had a low risk of hepatic decompensation (5-year cumulative incidence: 1.7%), and importantly, the risk of hepatic decompensation did not differ between those with/without an LSM decrease of ≥20% (p = 0.550). CONCLUSIONS: FU-LSM is key for risk stratification after HCV cure and should guide clinical decision making. LSM dynamics do not hold significant prognostic information in patients with FU-LSM 10-19.9 kPa, and thus, their consideration is not of sufficient incremental value in the specific context of HCV cure. IMPACT AND IMPLICATIONS: Liver stiffness measurement (LSM) is increasingly applied as a prognostic biomarker and commonly decreases in patients with compensated advanced chronic liver disease achieving HCV cure. Although Baveno VII proposed criteria for a clinically significant decrease, little is known about the prognostic utility of LSM dynamics (changes through antiviral therapy). Interestingly, in those with a post-treatment LSM of 10-19.9 kPa, LSM dynamics did not provide incremental information, arguing against the consideration of LSM dynamics as prognostic criteria. Thus, post-treatment LSM should guide the management of patients with compensated advanced chronic liver disease achieving HCV cure.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatitis C Crónica , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Hepatitis C Crónica/tratamiento farmacológico , Hepatitis C Crónica/complicaciones , Antivirales/uso terapéutico , Cirrosis Hepática/epidemiología , Pronóstico , Anciano , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/epidemiología , Neoplasias Hepáticas/etiología , Adulto , Carcinoma Hepatocelular/epidemiología , Carcinoma Hepatocelular/etiología
12.
Clin Gastroenterol Hepatol ; 22(10): 2053-2061, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38777174

RESUMEN

BACKGROUND & AIMS: Although upper gastrointestinal endoscopy (EGD) remains the gold standard for detecting varices in cirrhosis, the Baveno VI criteria proposed a combination of transient elastography and platelet count that could rule out high-risk varices, therefore sparing the need for an endoscopy, with significant potential cost savings. We performed a cost-effectiveness analysis of the Baveno VI criteria compared with EGD in the diagnosis of high-risk varices in cirrhosis. METHODS: We built an analytical decision model to estimate the cost and benefits of using the Baveno VI criteria compared with EGD in patients with Child-Pugh A cirrhosis. The analysis was performed from the UK National Health Service perspective, over 1, 5, and 20 years. A Markov model was populated with data from published evidence. Outcomes were measured in terms of quality-adjusted life years (QALYs) and avoided deaths. The analyses were repeated for Canada and Spain, using relevant cost inputs. RESULTS: The Baveno VI criteria were cost effective compared with endoscopy in all analyses. For 1000 patients, they produced 0.16 additional QALYs at an incremental cost of £326 ($443.41) over 5 years, resulting in an incremental cost of £2081 ($2830) per additional QALY gained. The incremental net monetary benefit of Baveno VI compared with EGD was £2808 ($3819) over 5 years per patient. Baveno VI criteria also were cost effective in Canada and Spain. Deterministic and probabilistic sensitivity analysis supported these findings. CONCLUSIONS: The findings demonstrate that the Baveno VI criteria are cost effective, suggesting that they should be considered for widespread implementation on the basis of safety, appropriateness, and economic grounds.


Asunto(s)
Análisis Costo-Beneficio , Várices Esofágicas y Gástricas , Cirrosis Hepática , Humanos , Cirrosis Hepática/complicaciones , Reino Unido , Várices Esofágicas y Gástricas/economía , Várices Esofágicas y Gástricas/diagnóstico , España , Canadá , Diagnóstico por Imagen de Elasticidad/economía , Diagnóstico por Imagen de Elasticidad/métodos , Masculino , Recuento de Plaquetas , Femenino , Persona de Mediana Edad , Años de Vida Ajustados por Calidad de Vida , Anciano , Adulto
13.
Clin Gastroenterol Hepatol ; 22(7): 1453-1461.e2, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38428706

RESUMEN

BACKGROUND & AIMS: In the American Gastroenterological Association/American Association for the Study of Liver Diseases (AGA/AASLD) Clinical Care Pathway, Fibrosis-4 index (FIB-4) is used to stratify patients at risk for metabolic dysfunction-associated steatotic liver disease (MASLD) as low-, indeterminate-, or high-risk for developing advanced liver fibrosis. We assessed the performance of FIB-4 in a general population. METHODS: Using the 2017 to 2020 National Health and Nutrition Examination Surveys dataset, we selected subjects ≥18 years who had FibroScan data. We followed AGA/AASLD guidelines to identify subjects with characteristics that place them at risk for MASLD-associated liver fibrosis. Other causes of liver disease were excluded. Our final cohort had 3741 subjects. We then categorized these subjects based on recommended FIB-4 cutoffs. FibroScan liver stiffness measurement (LSM) served as the outcome measurement. RESULTS: Among the 2776 subjects (74.2%) classified as low risk by FIB-4, 277 subjects (10%) were not classified at low risk by LSM, and 75 subjects (2.7%) were classified as high risk by LSM. Among the 86 subjects classified as high risk by FIB-4, 68 subjects (79.1%) were not at high risk by LSM, and 54 subjects (62.8%) were at low risk by LSM. Subjects misclassified by FIB-4 as low risk were older; had a higher body mass index, waist circumference, glycohemoglobin A1c level, alanine transaminase, aspartate transaminase, diastolic blood pressure, controlled attenuation parameter score, white blood cell count, alkaline phosphatase, and fasting glucose level; but had lower high-density lipoprotein, and albumin level (all P < .05). Misclassified subjects were also more likely to have prediabetes/diabetes. CONCLUSION: Using FIB-4 in the AGA/AASLD guidelines to risk-stratify subjects at risk for MASLD-associated fibrosis results in many subjects being misclassified into the low- and high-risk categories. Therefore, it may be worthwhile considering caution in interpretation and/or alternative strategies.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Cirrosis Hepática/diagnóstico por imagen , Guías de Práctica Clínica como Asunto , Medición de Riesgo/métodos , Anciano , Encuestas Nutricionales , Estudios de Cohortes , Índice de Severidad de la Enfermedad , Estados Unidos , Hígado Graso/diagnóstico por imagen , Hígado/diagnóstico por imagen , Hígado/patología
14.
Breast Cancer Res Treat ; 207(3): 569-578, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38851662

RESUMEN

BACKGROUND: An increasing number of women are choosing mastectomy and subpectoral implant (SI) breast reconstruction over breast-conserving therapy (BCT). It is unclear to what extent these procedures differ in their effect on the pectoralis major (PM). The purpose of this study was to assess the impact of choosing BCT or SI breast reconstruction on PM function. METHODS: Ultrasound shear wave elastography images were acquired from the PM fiber regions and surface electromyography obtained activity from six shoulder muscles, while 14 BCT participants, 14 SI participants, and 14 age-matched controls remained at rest or generated submaximal shoulder torques. RESULTS: BCT and SI participants were significantly weaker in shoulder adduction, while BCT participants were also weaker in internal and external rotation (all p ≤ 0.003). PM function was altered following either BCT or SI. In all treatment groups, the clavicular fiber region contributed primarily to flexion, and the sternocostal primarily contributed to adduction. However, healthy participants utilized the clavicular region more during adduction and the sternocostal region more during flexion when compared to BCT or SI participants (all p ≤ 0.049). The still intact clavicular region increased its contributions to flexion torques in SI participants compared to controls (p = 0.016). Finally, BCT and SI participants compensated for changes in PM function using synergistic shoulder musculature. CONCLUSION: Both BCT and SI breast reconstruction result in significant long-term upper extremity strength deficits. Our results suggest changes to the underlying function of the PM and the adoption of unique but inadequate neuromuscular compensation strategies drive these deficits.


Asunto(s)
Neoplasias de la Mama , Músculos Pectorales , Humanos , Femenino , Músculos Pectorales/cirugía , Persona de Mediana Edad , Neoplasias de la Mama/cirugía , Adulto , Mastectomía Segmentaria/métodos , Electromiografía , Mastectomía/métodos , Mastectomía/efectos adversos , Diagnóstico por Imagen de Elasticidad/métodos , Mamoplastia/métodos , Implantes de Mama , Fuerza Muscular , Estudios de Casos y Controles , Hombro/cirugía , Rango del Movimiento Articular
15.
Radiology ; 311(1): e231461, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38652028

RESUMEN

Background Noninvasive tests can be used to screen patients with chronic liver disease for advanced liver fibrosis; however, the use of single tests may not be adequate. Purpose To construct sequential clinical algorithms that include a US deep learning (DL) model and compare their ability to predict advanced liver fibrosis with that of other noninvasive tests. Materials and Methods This retrospective study included adult patients with a history of chronic liver disease or unexplained abnormal liver function test results who underwent B-mode US of the liver between January 2014 and September 2022 at three health care facilities. A US-based DL network (FIB-Net) was trained on US images to predict whether the shear-wave elastography (SWE) value was 8.7 kPa or higher, indicative of advanced fibrosis. In the internal and external test sets, a two-step algorithm (Two-step#1) using the Fibrosis-4 Index (FIB-4) followed by FIB-Net and a three-step algorithm (Three-step#1) using FIB-4 followed by FIB-Net and SWE were used to simulate screening scenarios where liver stiffness measurements were not or were available, respectively. Measures of diagnostic accuracy were calculated using liver biopsy as the reference standard and compared between FIB-4, SWE, FIB-Net, and European Association for the Study of the Liver guidelines (ie, FIB-4 followed by SWE), along with sequential algorithms. Results The training, validation, and test data sets included 3067 (median age, 42 years [IQR, 33-53 years]; 2083 male), 1599 (median age, 41 years [IQR, 33-51 years]; 1124 male), and 1228 (median age, 44 years [IQR, 33-55 years]; 741 male) patients, respectively. FIB-Net obtained a noninferior specificity with a margin of 5% (P < .001) compared with SWE (80% vs 82%). The Two-step#1 algorithm showed higher specificity and positive predictive value (PPV) than FIB-4 (specificity, 79% vs 57%; PPV, 44% vs 32%) while reducing unnecessary referrals by 42%. The Three-step#1 algorithm had higher specificity and PPV compared with European Association for the Study of the Liver guidelines (specificity, 94% vs 88%; PPV, 73% vs 64%) while reducing unnecessary referrals by 35%. Conclusion A sequential algorithm combining FIB-4 and a US DL model showed higher diagnostic accuracy and improved referral management for all-cause advanced liver fibrosis compared with FIB-4 or the DL model alone. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ghosh in this issue.


Asunto(s)
Algoritmos , Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Humanos , Masculino , Cirrosis Hepática/diagnóstico por imagen , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Adulto , Aprendizaje Profundo , Hígado/diagnóstico por imagen , Hígado/patología , Anciano , Ultrasonografía/métodos
16.
Radiology ; 311(2): e233136, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38742971

RESUMEN

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Diagnóstico por Imagen de Elasticidad/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Reproducibilidad de los Resultados , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/diagnóstico por imagen
17.
Radiology ; 312(3): e233094, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39254458

RESUMEN

Background US shear-wave elastography (SWE) and vibration-controlled transient elastography (VCTE) enable assessment of liver stiffness, an indicator of fibrosis severity. However, limited reproducibility data restrict their use in clinical trials. Purpose To estimate SWE and VCTE measurement variability in nonalcoholic fatty liver disease (NAFLD) within and across systems to support clinical trial diagnostic enrichment and clinical interpretation of longitudinal liver stiffness. Materials and Methods This prospective, observational, cross-sectional study (March 2021 to November 2021) enrolled adults with NAFLD, stratified according to the Fibrosis-4 (FIB-4) index (≤1.3, >1.3 and <2.67, ≥2.67), at two sites to assess SWE with five US systems and VCTE with one system. Each participant underwent 12 elastography examinations over two separate days within 1 week, with each day's examinations conducted by a different operator. VCTE and SWE measurements were reported in units of meters per second. The primary end point was the different-day, different-operator reproducibility coefficient (RDCDDDO) pooled across systems for SWE and individually for VCTE. Secondary end points included system-specific RDCDDDO, same-day, same-operator repeatability coefficient (RCSDSO), and between-system same-day, same-operator reproducibility coefficient. The planned sample provided 80% power to detect a pooled RDCDDDO of less than 35%, the prespecified performance threshold. Results A total of 40 participants (mean age, 60 years ± 10 [SD]; 24 women) with low (n = 17), intermediate (n = 15), and high (n = 8) FIB-4 scores were enrolled. RDCDDDO was 30.7% (95% upper bound, 34.4%) for SWE and 35.6% (95% upper bound, 43.9%) for VCTE. SWE system-specific RDCDDDO varied from 24.2% to 34.3%. The RCSDSO was 21.0% for SWE (range, 13.9%-35.0%) and 19.6% for VCTE. The SWE between-system same-day, same-operator reproducibility coefficient was 52.7%. Conclusion SWE met the prespecified threshold, RDCDDDO less than 35%, with VCTE having a higher RDCDDDO. SWE variability was higher between different systems. These estimates advance liver US-based noninvasive test qualification by (a) defining expected variability, (b) establishing that serial examination variability is lower when performed with the same system, and (c) informing clinical trial design. ClinicalTrials.gov Identifier NCT04828551 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Femenino , Masculino , Reproducibilidad de los Resultados , Persona de Mediana Edad , Estudios Prospectivos , Estudios Transversales , Adulto , Hígado/diagnóstico por imagen , Anciano , Cirrosis Hepática/diagnóstico por imagen
18.
Radiology ; 313(1): e240705, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39404634

RESUMEN

Background There is variable evidence and no randomized trials on the benefit of US elastography-guided fine-needle aspiration cytology (FNAC) over conventional US-guided FNAC alone for thyroid nodules. Purpose To compare the efficacy of US elastography-guided FNAC versus US-guided FNAC in reducing nondiagnostic rates for thyroid nodules. Materials and Methods A pragmatic, multicenter randomized controlled trial was performed at 18 secondary and tertiary hospitals across England between February 2015 and September 2018. Eligible adults with single or multiple thyroid nodules who had not previously undergone FNAC were randomized (1:1 ratio) to US elastography FNAC (intervention) or conventional US FNAC (control). The primary outcome was the proportion of patients who have a nondiagnostic cytologic Thy1 (British Thyroid Association system) result following the first FNAC. Results A total of 982 participants (mean age, 51.3 years ± 15 [SD] [IQR, 39-63]; male-to-female ratio, 1:4) were randomized. Of the 493 participants who underwent US elastography, 467 (94.7%) were examined with strain US elastography. There was no difference between the two arms in the nondiagnostic (Thy1) rate following the first FNAC (19% vs 16%; risk difference [RD], 0.03 [95% CI: -0.01, 0.07]; P = .11) or in the median time to reach the final definitive diagnosis (3.3 months [IQR, 1.5-6.4] for US elastography FNAC vs 3.4 months [IQR, 1.5-6.2] for US FNAC). All sensitivity analyses supported the primary analysis. Fewer participants in the US elastography FNAC arm underwent diagnostic hemithyroidectomy than in the US FNAC arm (183 of 493 [37%] vs 196 of 489 [40%]), but this was not statistically significant (adjusted RD, 0.02 [95% CI: -0.06, 0.01]; P = 0.15). There was no evidence of a difference in malignancy rates between the two arms: 70 of 493 (14%) in US elastography FNAC arm versus 79 of 489 (16%) in US FNAC arm (P = .39). There was also no difference in the rate of benign histologic findings between the groups (RD, -0.01 [95% CI: -0.04, 0.03]; P = .7). Conclusion Strain US elastography does not appear to have additional benefit over conventional US FNAC in the diagnosis of malignancy in thyroid nodules. Clinical trial registration no. ISRCTN18261857 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Isikbay and Harwin in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Nódulo Tiroideo , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Masculino , Femenino , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Nódulo Tiroideo/cirugía , Persona de Mediana Edad , Adulto , Biopsia con Aguja Fina , Biopsia Guiada por Imagen/métodos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Ultrasonografía Intervencional/métodos
19.
Radiology ; 311(3): e232242, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38832881

RESUMEN

Background Pathologic lymphovascular space invasion (LVSI) is associated with poor outcome in endometrial cancer. Its relationship with tumor stiffness, which can be measured with use of MR elastography, has not been extensively explored. Purpose To assess whether MR elastography-based mechanical characteristics can aid in the noninvasive prediction of LVSI in patients with endometrial cancer. Materials and Methods This prospective study included consecutive adult patients with a suspected uterine tumor who underwent MRI and MR elastography between October 2022 and July 2023. A region of interest delineated on T2-weighted magnitude images was duplicated on MR elastography images and used to calculate c (stiffness in meters per second) and φ (viscosity in radians) values. Pathologic assessment of hysterectomy specimens for LVSI served as the reference standard. Data were compared between LVSI-positive and -negative groups with use of the Mann-Whitney U test. Multivariable logistic regression was used to determine variables associated with LVSI positivity and develop diagnostic models for predicting LVSI. Model performance was assessed with use of area under the receiver operating characteristic curve (AUC) and compared using the DeLong test. Results A total of 101 participants were included, 72 who were LVSI-negative (median age, 53 years [IQR, 48-62 years]) and 29 who were LVSI-positive (median age, 54 years [IQR, 49-60 years]). The tumor stiffness in the LVSI-positive group was higher than in the LVSI-negative group (median, 4.1 m/sec [IQR, 3.2-4.6 m/sec] vs 2.2 m/sec [IQR, 2.0-2.8 m/sec]; P < .001). Tumor volume, cancer antigen 125 level, and tumor stiffness were associated with LVSI positivity (adjusted odds ratio range, 1.01-9.06; P range, <.001-.04). The combined model (AUC, 0.93) showed better performance for predicting LVSI compared with clinical-radiologic model (AUC, 0.77; P = .003) and similar performance to the MR elastography-based model (AUC, 0.89; P = .06). Conclusion The addition of tumor stiffness as measured at MR elastography into a clinical-radiologic model improved prediction of LVSI in patients with endometrial cancer. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ehman in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias Endometriales , Imagen por Resonancia Magnética , Invasividad Neoplásica , Humanos , Femenino , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias Endometriales/diagnóstico por imagen , Neoplasias Endometriales/patología , Persona de Mediana Edad , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Metástasis Linfática/diagnóstico por imagen , Valor Predictivo de las Pruebas
20.
Biol Reprod ; 110(6): 1100-1114, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609185

RESUMEN

The ovary is one of the first organs to show overt signs of aging in the human body, and ovarian aging is associated with a loss of gamete quality and quantity. The age-dependent decline in ovarian function contributes to infertility and an altered endocrine milieu, which has ramifications for overall health. The aging ovarian microenvironment becomes fibro-inflammatory and stiff with age, and this has implications for ovarian physiology and pathology, including follicle growth, gamete quality, ovulation dynamics, and ovarian cancer. Thus, developing a non-invasive tool to measure and monitor the stiffness of the human ovary would represent a major advance for female reproductive health and longevity. Shear wave elastography is a quantitative ultrasound imaging method for evaluation of soft tissue stiffness. Shear wave elastography has been used clinically in assessment of liver fibrosis and characterization of tendinopathies and various neoplasms in thyroid, breast, prostate, and lymph nodes as a non-invasive diagnostic and prognostic tool. In this study, we review the underlying principles of shear wave elastography and its current clinical uses outside the reproductive tract as well as its successful application of shear wave elastography to reproductive tissues, including the uterus and cervix. We also describe an emerging use of this technology in evaluation of human ovarian stiffness via transvaginal ultrasound. Establishing ovarian stiffness as a clinical biomarker of ovarian aging may have implications for predicting the ovarian reserve and outcomes of Assisted Reproductive Technologies as well as for the assessment of the efficacy of emerging therapeutics to extend reproductive longevity. This parameter may also have broad relevance in other conditions where ovarian stiffness and fibrosis may be implicated, such as polycystic ovarian syndrome, late off target effects of chemotherapy and radiation, premature ovarian insufficiency, conditions of differences of sexual development, and ovarian cancer. Summary sentence:  Shear Wave Elastography is a non-invasive technique to study human tissue stiffness, and here we review its clinical applications and implications for reproductive health and disease.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ovario , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Ovario/diagnóstico por imagen , Ovario/fisiología , Envejecimiento/fisiología , Reproducción/fisiología , Salud Reproductiva
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda