Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Neurointerv Surg ; 11(11): 1141-1144, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30979847

RESUMEN

INTRODUCTION: The low-profile Neuroform Atlas stent received FDA Humanitarian Device Exemption status (HDE) in January 2018 for stent-assisted coil embolization of wide-necked saccular aneurysms. We review and report our results with the Atlas stent in our institution within the first year after its HDE approval. METHODS: Our retrospective chart review identified patients treated with the Atlas stent. We analyzed the patient demographics, aneurysm characteristics, stent parameters and configuration, complications, angiographic, and clinical outcomes at discharge. RESULTS: From January to December 2018, 76 Atlas stents were deployed in 58 patients (average 1.3 stents/patient). Median patient age was 63.5 (IQR 56-71) years. Fifty-six (96.6%) patients had elective embolization of unruptured aneurysms, while two (3.4%) patients underwent embolization of a ruptured aneurysm within 2 weeks of subarachnoid hemorrhage. Forty (69.0%) patients were treated with a single stent, 15 (25.9%) with a Y-stent, and three (5.2%) with X-stent configuration. All stent deployments were technically successful. Most stents (82.9%) were the smallest 3 mm diameter devices. Procedural complications included transient stent-associated thrombosis in three (5.2%) patients and aneurysm rupture in one (1.7%). None had distal embolization, associated cerebral infarction, or permanent neurological deficits. Immediate Raymond-Roy 1 occlusion was achieved in 41 (70.7%) patients. Median hospital length of stay for elective aneurysm embolization was 1 day. Excellent outcomes with median National Institute of Health Stroke Scale score 0 (IQR 0-0) and modified Rankin Score 0 (IQR 0-1) were seen for elective patients at discharge. CONCLUSION: The Neuroform Atlas stent provided a reliable technical and safety profile for the treatment of intracranial wide-neck aneurysms. Further experience is needed to determine long-term durability and safety of this device.


Asunto(s)
Aneurisma Roto/terapia , Prótesis Vascular , Ensayos de Uso Compasivo/instrumentación , Aneurisma Intracraneal/terapia , Stents Metálicos Autoexpandibles , Adulto , Anciano , Aneurisma Roto/diagnóstico por imagen , Angiografía Cerebral/métodos , Ensayos de Uso Compasivo/métodos , Embolización Terapéutica/métodos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
2.
J Neurointerv Surg ; 11(8): 801-806, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30670625

RESUMEN

BACKGROUND AND OBJECTIVE: Stent-assisted coil embolization is a well-established treatment of intracranial wide-necked aneurysms. The Neuroform Atlas Stent System is a new generation microstent designed to enhance coil support, conformability, deliverability, and improve deployment accuracy. We present the 1-year efficacy and angiographic results of the Humanitarian Device Exemption (HDE) cohort from the Atlas Investigational Device Exemption (IDE) clinical trial. METHOD: The Atlas IDE trial is a prospective, multicenter, single-arm, open-label study of unruptured wide-necked intracranial aneurysms treated with the Neuroform Atlas stent and approved coils. The primary efficacy endpoint was the rate of 12-month complete aneurysm angiographic occlusion (Raymond class I) without target aneurysm retreatment or significant parent artery stenosis (>50%) at the target location. The primary safety endpoint was the rate of major ipsilateral stroke or neurological death within 12 months. Imaging core laboratory and Clinical EventsCommittee adjudicated the primary endpoints. RESULTS: 30 patients were enrolled at eight US centers, with 27 patients completing the 12-month angiographic follow-up. The mean age was 59.4±11.8 years and 24/30 patients (80%) were women. The mean aneurysm size was 5.3±1.7 mm and the dome:neck ratio was 1.1±0.2. Procedural technical success of Neuroform Atlas Stent deployment was 100%. 27 patients completed 12-month angiographic follow-up and 30 patients completed their 6-month follow-up. When applying the last observation carried forward method, the primary efficacy endpoint was observed in 26/30 patients (86.7%, 95% CI 69.3% to 96.2%) compared with 25/27 patients (92.6%, 95% CI 75.7% to 99.1%) who completed the 12-month angiographic follow-up. The primary safety endpoint of stroke occurred in one patient (3.3%), who made a complete clinical recovery at discharge. There were no neurological deaths. CONCLUSION: The Neuroform Atlas stent in conjunction with coils demonstrated a high rate of complete aneurysm occlusion at 12-month angiographic follow-up, with an improved safety profile in the HDE cohort. CLINICAL TRIALGOV REGISTRATION NUMBER: NCT0234058;Results.


Asunto(s)
Ensayos de Uso Compasivo/instrumentación , Ensayos de Uso Compasivo/tendencias , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Stents Metálicos Autoexpandibles , Adulto , Anciano , Prótesis Vascular/tendencias , Angiografía Cerebral/métodos , Angiografía Cerebral/tendencias , Estudios de Cohortes , Ensayos de Uso Compasivo/métodos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Embolización Terapéutica/tendencias , Femenino , Humanos , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Alta del Paciente/tendencias , Estudios Prospectivos , Retratamiento/tendencias , Resultado del Tratamiento
3.
J Interv Card Electrophysiol ; 42(1): 11-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25595627

RESUMEN

BACKGROUND: Percutaneous left atrial appendage (LAA) ligation using an epicardial suture system (LARIAT®, SentreHEART, Palo Alto, CA) has been used in patients with nonvalvular atrial fibrillation (AF) and contraindication to oral anticoagulation. However, complex LAA anatomy may preclude its use. We report the safety and effectiveness of compassionate use of first-generation LARIAT® device for epicardial ligation of large, complex left atrial appendages. METHODS: Between January 2010 and March 2013, 93 patients with AF, high CHADS2 score, and contraindication(s) for oral anticoagulation therapy were evaluated for LAA ligation. Complex anatomy detected by 3D cardiac computed tomography CT angiography led to preclusion of 25 patients (27%). Of these, nine patients who opted for epicardial LAA ligation on compassionate grounds were studied. RESULTS: Mean age was 68.1 ± 8.2 years, four females, all with large LAA width (>40 mm, 45-58 mm) and additional anatomic complexities such as bilobed (two), long C-shaped-like (two), goose neck-like (one), multilobed cauliflower-like (two), cactus-like (one), and chicken wing-like (one) LAA. LAA ligation with LARIAT® was successfully performed with surgical standby in all patients. Seven patients (78%) were safely treated percutaneously and only two patients required minimally invasive thoracotomy (one due to inability to release the epicardial snare from long C-shaped LAA and other due to preexisting adhesions precluding pericardial entry). There were no major complications. Repeat trans-esophageal echocardiography at 3 months showed no remnant flow and none had stroke off Coumadin at 19.3 ± 8.2 months of follow-up. CONCLUSIONS: Despite a high preclusion rate, percutaneous LAA ligation may be safely and effectively performed on compassionate grounds using the first-generation LARIAT® device with surgical standby in patients with large and complex LAA.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ensayos de Uso Compasivo/instrumentación , Sistema de Conducción Cardíaco/cirugía , Pericardio/cirugía , Técnicas de Sutura/instrumentación , Anciano , Diseño de Equipo , Análisis de Falla de Equipo , Seguridad de Equipos , Femenino , Humanos , Ligadura/instrumentación , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda