Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 186
Filtrar
1.
Medicina (Kaunas) ; 56(2)2020 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-32079310

RESUMEN

BACKGROUND: Osteoporotic spinal fractures commonly occur in elderly patients with low bone mineral density. In these cases, percutaneous vertebroplasty or percutaneous kyphoplasty can provide significant pain relief and improve mobility. However, studies have reported both the recurrence of vertebral compression fractures at the index level after vertebroplasty and the development of new vertebral fractures at the adjacent level that occur without any additional trauma. Pedicle screw fixation combined with percutaneous vertebroplasty has been proposed as an effective procedure for addressing osteoporotic thoracolumbar fractures. However, in osteoporotic populations, pedicle screws can loosen, pullout, or migrate. Currently, the efficacy of cortical bone trajectory screw fixation for osteoporotic fractures remains unclear. Thus, we assessed the effects of using cortical bone trajectory instrumentation with vertebroplasty on patient outcomes. METHOD: We retrospectively reviewed data from 12 consecutively sampled osteoporotic thoracolumbar fracture patients who underwent cortical bone trajectory instrumentation with vertebroplasty. Patients were enrolled beginning in October 2015 and were followed for >24 months. RESULT: The average age was 74 years, and the average dual-energy x-ray absorptiometry T-score was -3.6. The average visual analog scale pain scores improved from 8 to 2.5 after surgery. The average blood loss was 36.25 mL. All patients regained ambulation and experienced reduced pain post-surgery. No recurrent fractures or instrument failures were recorded during follow-up. CONCLUSIONS: Our findings suggest that cortical bone trajectory instrumentation combined with percutaneous vertebroplasty may be a good option for treating osteoporotic thoracolumbar fractures, as it can prevent recurrent vertebral fractures or related kyphosis in sagittal alignment.


Asunto(s)
Hueso Cortical/cirugía , Fracturas por Compresión/cirugía , Osteoporosis/complicaciones , Vertebroplastia/instrumentación , Anciano , Anciano de 80 o más Años , Hueso Cortical/lesiones , Femenino , Fracturas por Compresión/etiología , Fracturas por Compresión/fisiopatología , Humanos , Vértebras Lumbares/lesiones , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Osteoporosis/cirugía , Estudios Retrospectivos , Taiwán , Vértebras Torácicas/lesiones , Vértebras Torácicas/fisiopatología , Resultado del Tratamiento , Vertebroplastia/métodos
2.
Osteoporos Int ; 30(10): 2151-2154, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31273389

RESUMEN

We report that a 33-year-old woman developed multiple compression fractures several years after a sleeve gastrectomy followed by pregnancy. Despite normal areal BMD values assessed by dual-energy X-ray absorptiometry and no family history of osteoporosis, the patient demonstrated low lumbar spine trabecular bone score, as well as low peripheral trabecular volumetric BMD and deterioration of trabecular microarchitecture assessed by high-resolution peripheral quantitative computed tomography. Women of reproductive age should be provided with lifestyle management targeting bone health following bariatric surgery.


Asunto(s)
Cirugía Bariátrica/efectos adversos , Fracturas por Compresión/etiología , Gastrectomía/efectos adversos , Fracturas Osteoporóticas/etiología , Fracturas de la Columna Vertebral/etiología , Adulto , Densidad Ósea/fisiología , Femenino , Cuello Femoral/fisiopatología , Fracturas por Compresión/fisiopatología , Articulación de la Cadera/fisiopatología , Humanos , Vértebras Lumbares/fisiopatología , Fracturas Osteoporóticas/fisiopatología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Embarazo , Fracturas de la Columna Vertebral/fisiopatología , Tibia/fisiopatología
3.
Osteoporos Int ; 30(12): 2459-2467, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31482304

RESUMEN

Sarcopenia was reported to be significantly associated with osteoporosis. In this study, we reported for the first time that sarcopenia was an independent risk predictor of osteoporotic vertebral compression refractures (OVCRFs). Other risk factors of OVCRFs are low bone mass density T-scores, female sex, and advanced age. INTRODUCTION: The purpose of this study was to investigate the association between osteoporotic vertebral compression refractures (OVCRFs) and sarcopenia, and to identify other risk factors of OVCRFs. METHODS: We evaluated 237 patients with osteoporotic vertebral compression fracture who underwent percutaneous kyphoplasty (PKP) in our hospital from August 2016 to December 2017. To diagnose sarcopenia, a cross-sectional computed tomography (CT) image at the inferior aspect of the third lumbar vertebra (L3) was selected for estimating muscle mass. Grip strength was used to assess muscle strength. Possible risk factors, such as age, sex, body mass index (BMI), bone mineral density (BMD), location of the treated vertebra, anterior-posterior ratio (AP ratio) of the fractured vertebra, cement leakage, and vacuum clefts, were assessed. The multivariable analysis was used to determine the risk factors of OVCRFs. RESULTS: During the follow-up period, OVCRFs occurred in 64 (27.0%) patients. Sarcopenia was present in 48 patients (20.3%), including 21 OVCRFs and 27 non-OVCRFs patients. Sarcopenia was significantly correlated with advanced age, lower BMI, lower BMD, and hypoalbuminemia. Compared with non-sarcopenic patients, sarcopenic patients had higher OVCRFs risk. In univariate analysis, sarcopenia (p = 0.003), female (p = 0.024), advanced age (≥ 75 years; p < 0.001), lower BMD (p < 0.001), lower BMI (p = 0.01), TL junction (vertebral levels at the thoracolumbar junction) (p = 0.01), cardiopulmonary comorbidity (p = 0.042), and hypoalbuminemia (p = 0.003) were associated with OVCRFs. Multivariable analysis revealed that sarcopenia (OR 2.271; 95% CI 1.069-4.824, p = 0.033), lower BMD (OR 1.968; 95% CI 1.350-2.868, p < 0.001), advanced age (≥ 75 years; OR 2.431; 95% CI 1.246-4.744, p = 0.009), and female sex (OR 4.666; 95% CI 1.400-15.552, p = 0.012) were independent risk predictors of OVCRFs. CONCLUSIONS: Sarcopenia is an independent risk predictor of osteoporotic vertebral compression refractures. Other factors affecting OVCRFs are low BMD T-scores, female sex, and advanced age.


Asunto(s)
Fracturas por Compresión/etiología , Fracturas Osteoporóticas/etiología , Sarcopenia/complicaciones , Fracturas de la Columna Vertebral/etiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Densidad Ósea/fisiología , Femenino , Estudios de Seguimiento , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Fracturas por Compresión/cirugía , Fuerza de la Mano , Humanos , Cifoplastia/métodos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/fisiopatología , Fracturas Osteoporóticas/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Sarcopenia/diagnóstico por imagen , Sarcopenia/fisiopatología , Factores Sexuales , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Fracturas de la Columna Vertebral/cirugía , Tomografía Computarizada por Rayos X
4.
Anticancer Drugs ; 30(6): 646-648, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30950837

RESUMEN

Vertebroplasty is a well-established treatment for both pathological and painful osteoporotic fractures. It is a frequently performed and generally low risk, but severe complications can occur. We report on a patient with metastatic breast cancer requiring vertebroplasty for pain relief who suffered an unusual complication: a pulmonary cement embolism. We describe our management of the case and the controversies related to the use of anticoagulation. In addition, we carried out a brief literature review of common practices in relation to this complication. This case highlights the difficulty of managing anticoagulation in the complex setting of cancer and the need for greater awareness among clinicians of this uncommon, but possibly catastrophic complication.


Asunto(s)
Anticoagulantes/uso terapéutico , Cementos para Huesos/efectos adversos , Neoplasias de la Mama/complicaciones , Fracturas por Compresión/cirugía , Embolia Pulmonar/tratamiento farmacológico , Vertebroplastia/efectos adversos , Adulto , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/patología , Femenino , Fracturas por Compresión/fisiopatología , Humanos , Pronóstico , Embolia Pulmonar/etiología
5.
Med Sci Monit ; 25: 1800-1805, 2019 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-30851031

RESUMEN

BACKGROUND Long-term hypocalcemia can result in osteoporotic vertebral compression fracture (OVCF). Transient paralysis and tetraplegia due to hypocalcemia is a rare but severe complication after kyphoplasty. The aims of this prospective clinical study were to investigate the clinical factors associated with serum calcium levels in patients undergoing percutaneous kyphoplasty (PKP). MATERIAL AND METHODS Sixty-eight patients with OVCF were clinically evaluated before and after PKP. Serum calcium was measured before surgery and 24 hours after surgery. Clinical information included the time between vertebral fracture and surgery, the number of involved vertebral bodies, the dose of bone cement required during surgery, and bone mineral density. Correlation coefficient and simple linear regression analysis were performed to identify the clinical factors associated with serum calcium levels. RESULTS Peri-operative serum calcium levels were significantly and positively associated with the dose of bone cement required during PKP and the number of affected vertebral bodies. There was a significant and negative correlation between the time from vertebral fracture to surgery and bone mineral density, which were shown by linear regression analysis to have a predictive value of 5.8% and 47.3%, respectively. CONCLUSIONS For patients undergoing PKP, the amount of bone cement required and the number of affected vertebral bodies were associated with low serum calcium levels. Surgeons should be aware of the importance of measuring and monitoring serum calcium levels in this patient group.


Asunto(s)
Calcio/análisis , Cifoplastia/métodos , Fracturas Osteoporóticas/metabolismo , Anciano , Anciano de 80 o más Años , Cementos para Huesos/metabolismo , Densidad Ósea , Calcio/sangre , China , Femenino , Fracturas por Compresión/fisiopatología , Humanos , Hipocalcemia/metabolismo , Hipocalcemia/cirugía , Vértebras Lumbares , Masculino , Persona de Mediana Edad , Periodo Perioperatorio , Estudios Prospectivos , Estudios Retrospectivos , Fracturas de la Columna Vertebral , Columna Vertebral , Resultado del Tratamiento
6.
Int Orthop ; 43(7): 1679-1683, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30022218

RESUMEN

PURPOSE: To promote the understanding of pelvic fracture mechanism and make more accurate evaluation of maximal deformity at the moment of fracture, kinematic response of pelvis to lateral impact and the difference between peak and final displacement were investigated. METHODS: A total of three human cadaver pelves were seated uprightly on a sled test table, explored to horizontal lateral impact by a 22.1-kg impactor at a speed of 5.2, 4.0, and 4.8 m/s. Kinematic data of pelvic osseous interesting points (POIP) were measured by the motion capture system. Trajectories of POIP, duration of impact, and deflection of pelvis were calculated as well as rotational movement of pelvis was evaluated. After impact, autopsy and CT scan were made to validate the motion capture data. RESULTS: The peak deflection of pelvis under lateral impact was 31.9, 30.1, and 18.5%, while final deflection was 19.6, 13.8, and 13.8%. The final deflection was only 61.5, 45.9, and 74.46% of the peak deflection. CONCLUSIONS: In clinical practice, pelvic fracture displacement tends to be underestimated. The peak compression can be 1.3-2.2 times of final compression appearing on images in hospital. Clinicians shall give adequate estimation of displacement and related injuries.


Asunto(s)
Fracturas Óseas/fisiopatología , Fracturas por Compresión/fisiopatología , Huesos Pélvicos/fisiopatología , Fenómenos Biomecánicos , Cadáver , Fracturas Óseas/diagnóstico por imagen , Fracturas por Compresión/diagnóstico por imagen , Humanos , Masculino , Modelos Anatómicos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/lesiones , Tomografía Computarizada por Rayos X
7.
Medicina (Kaunas) ; 55(8)2019 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-31370309

RESUMEN

Background and objectives: Tumor-related vertebral compression fractures often result in severe back pain as well as progressive neurologic impairment and additional morbidities. The fixation of these fractures is essential to obtain good pain relief and to improve the patients' quality of life. Thus far, several spine implants have been developed and studied. The aims of this review were to describe the implants and the techniques proposed to treat cancer-related vertebral compression fractures and to compile their safety and efficacy results. Materials and Methods: A systematic MEDLINE/PubMed literature search was performed, time period included articles published between January 2000 and March 2019. Original articles were selected based on their clinical relevance. Results: Four studies of interest and other cited references were analyzed. These studies reported significant pain and function improvement as well as kyphotic angle and vertebral height restoration and maintain for every implant and technique investigated. Conclusions: Although good clinical performance is reported on these devices, the small numbers of studies and patients investigated draw the need for further larger evaluation before drawing a definitive treatment decision tree to guide physicians managing patients presenting with neoplastic vertebral compression fracture.


Asunto(s)
Fracturas por Compresión/etiología , Neoplasias/complicaciones , Prótesis e Implantes/normas , Fracturas de la Columna Vertebral/cirugía , Fracturas por Compresión/fisiopatología , Humanos , Neoplasias/fisiopatología , Prótesis e Implantes/tendencias , Calidad de Vida/psicología , Fracturas de la Columna Vertebral/fisiopatología , Columna Vertebral/fisiopatología , Columna Vertebral/cirugía , Resultado del Tratamiento
8.
Osteoporos Int ; 28(1): 329-338, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27480628

RESUMEN

This study evaluated the use of low-dose chest computed tomography (LDCT) for detecting bone fragility. LDCT-measured vertebral bone attenuation by volumetric methods showed good correlation with bone mineral density (BMD) measured by dual-energy x-ray absorptiometry (DXA, and good diagnostic performance for identifying osteoporosis and compression fractures. The results of this study suggest the feasibility of obtaining comprehensive information on bone health in subjects undergoing LDCT. INTRODUCTION: Osteoporosis is a prevalent but underdiagnosed disease that increases fracture risk. This study evaluated the utility of vertebral attenuation derived from low-dose chest computed tomography (LDCT) compared to dual-energy x-ray absorptiometry (DXA) for detecting bone fragility. METHODS: A total of 232 subjects (78 men and 154 women) aged above 50 years who underwent both LDCT and DXA within 30 days were evaluated. LDCT-measured bone attenuation in Hounsfield units (HU) of four vertebrae (T4, T7, T10, and L1) was evaluated using volumetric methods for correlation with DXA-measured bone mineral density (BMD) and for the diagnosis of compression fractures, osteoporosis, and low BMD (osteoporosis or osteopenia) in men and women, with DXA measurements as the reference standard. RESULTS: The average attenuation of the four vertebrae showed strong correlation with DXA-measured BMD of the lumbar spine (r = 0.726, p < 0.05). In receiver-operating characteristic (ROC) analyses, the area under the curve (AUC) across LDCT-measured thresholds of the average attenuation to distinguish compression fractures was 0.827, and a threshold of 129.5 HU yielded 90.9 % sensitivity and 64.4 % specificity. Similarly, average attenuation showed high AUCs and good diagnostic performance for detecting osteoporosis and low BMD in both men and women. Among 44 subjects with compression fractures, the average bone attenuation showed strong negative correlation with both the worst fracture grade (r = -0.525, p < 0.05) and cumulative fracture grade score (r = -0.633, p < 0.05). CONCLUSION: LDCT-measured bone attenuation by volumetric methods showed good correlation with BMD measured by DXA and good diagnostic performance for identifying bone fragility.


Asunto(s)
Osteoporosis/diagnóstico por imagen , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Absorciometría de Fotón/métodos , Anciano , Densidad Ósea/fisiología , Estudios de Factibilidad , Femenino , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteoporosis/fisiopatología , Fracturas Osteoporóticas/fisiopatología , Dosis de Radiación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología
9.
Med Sci Monit ; 23: 5994-6000, 2017 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-29252980

RESUMEN

BACKGROUND Balloon kyphoplasty (KP) has been widely applied in the treatment of elderly patients with osteoporosis vertebral compression fracture (OVCF), but there has been little research on the pain relief effect. Therefore, we performed this study of patients who received KP. The study included a set of fluoroscopy tests and follow-up evaluation, which aimed to verify the effectiveness of kyphoplasty in controlling back pain associated with OVCFs. MATERIAL AND METHODS Forty-three OVCF patients underwent kyphoplasty: 21 were allocated to an intervention group and 22 were allocated to a control group, and the 2 groups received treatment with different KP instruments. The variation of vertebral height was measured on X-ray and change of signal of MRI was recorded. The pain was assessed by VAS score and diagram, and physical function was evaluated by ODI. The complications after surgery were recorded and collated during 2 years of follow-up. RESULTS The intervention group showed no significant difference on the VAS and ODI compared to the control group (p>0.05). There was no difference in the VAS with different degrees of radiological change (p>0.05). Signal change on MRI imaging was rare. CONCLUSIONS Kyphoplasty is a positive way to alleviate early-onset OVCF pain. The change of BME extent in the treated level is unrelated to the relief of back pain after KP.


Asunto(s)
Fracturas por Compresión/fisiopatología , Dimensión del Dolor/métodos , Dolor/fisiopatología , Anciano , Anciano de 80 o más Años , Dolor de Espalda/tratamiento farmacológico , Femenino , Fluoroscopía , Fracturas por Compresión/cirugía , Humanos , Cifoplastia/métodos , Masculino , Osteoporosis/complicaciones , Fracturas Osteoporóticas/cirugía , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Fracturas de la Columna Vertebral/cirugía , Columna Vertebral/cirugía , Resultado del Tratamiento
10.
BMC Musculoskelet Disord ; 18(1): 176, 2017 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-28454529

RESUMEN

BACKGROUND: Numerous reported studies have shown that vertebral compression fractures are associated with impaired function or disability; however, few examined their association with objective measures of physical performance or functioning. METHODS: We examined the association of vertebral compression fractures with physical performance measures in 556 Japanese women aged 40-89 years. Lateral spine radiographs were obtained and radiographic vertebral compression fractures were assessed by quantitative morphometry, defined as vertebral heights more than 3 SD below the normal mean. Measures of physical performance included walking speed, chair stand time and functional reach. Adjusted means of performance-based measures according to the number and severity of vertebral compression fractures were calculated using general linear modeling methods. RESULTS: After adjusting for age, body mass index, back pain, number of painful joints, number of comorbidities and regular physical activities, the walking speed of women with two or more compression fractures (1.17 m/s) was significantly slower than that of women without compression fracture (1.24 m/s) (p = 0.03). Compared with women without compression fracture, chair stand time was longer in women with two or more compression fractures (p = 0.01), and functional reach was shorter (p = 0.01). No significant differences were observed in walking speed, chair stand time, or functional reach between women with one compression fracture and those without compression fracture. CONCLUSIONS: Having multiple vertebral compression fractures affects physical performance in community-dwelling Japanese women. Poor physical functioning may lead to functional dependence, accelerated bone loss, and increased risk for falls, injuries, and fractures. Preventing vertebral compression fracture is considered important for preserving the independence of older adults.


Asunto(s)
Pueblo Asiatico , Ejercicio Físico/fisiología , Fracturas por Compresión/epidemiología , Vida Independiente , Fracturas de la Columna Vertebral/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Humanos , Vida Independiente/tendencias , Japón/epidemiología , Persona de Mediana Edad , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología
11.
Eur J Orthop Surg Traumatol ; 27(1): 87-92, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27577730

RESUMEN

PURPOSE: In the healing of osteoporotic vertebral fracture, global spinal mal-alignment might increase the load sharing at the fracture site and deteriorate the fracture healing. This study aimed to evaluate the effect of spinopelvic alignment on the union status of thoracolumbar osteoporosis-related vertebral compression fracture (OVCF). METHODS: Consecutive 48 patients with a single-level thoracolumbar fresh OVCF were treated non-operatively. Union was judged by three independent observers at 6 months, and patients were divided into union group and non-union group. Spinopelvic alignment was measured using upright whole spine radiograph before treatment as follows: pelvic incidence (PI), pelvic tilt (PT), lumbar lordosis (LL), thoracic kyphosis (TK), sagittal vertical axis (SVA), and DSVA, defined as the distance from a plumb line dropped from the center of the C7 body to the center of fractured vertebral body. RESULT: Global spinal alignment was different in union group and non-union group: SVA (4.7 ± 0.7 cm in union group vs. 8.9 ± 1.3 cm in non-union group, P = 0.007), DSVA (4.2 ± 0.6 cm in union group vs. 9.5 ± 1.0 cm in non-union group, P < 0.001), and PI-LL (18.9° ± 2.2° in union group vs. 30.3° ± 3.9° in non-union group, P = 0.014). Over 5 cm of DSVA [P = 0.022, adjusted odds 7.9 (95 % CI 1.3-77.0)] and/or over 30° of PI-LL [P = 0.026, adjusted odds 6.6 (95 % CI 1.5-44.2)] showed the significant risk factors for non-union using multivariate logistic regression analysis in the other background status. CONCLUSIONS: Global spinal mal-alignment, showing over 5 cm of DSVA and/or over 30° of PI-LL, affected the union status of OVCF.


Asunto(s)
Desviación Ósea/etiología , Curación de Fractura/fisiología , Fracturas por Compresión/terapia , Fracturas Osteoporóticas/terapia , Fracturas de la Columna Vertebral/terapia , Anciano , Anciano de 80 o más Años , Desviación Ósea/fisiopatología , Femenino , Fracturas por Compresión/fisiopatología , Humanos , Vértebras Lumbares/lesiones , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/fisiopatología , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/lesiones , Resultado del Tratamiento
12.
Eur Spine J ; 25(2): 607-13, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26411349

RESUMEN

PURPOSE: Different treatment methods including immediate mobilization with or without brace, bed rest or immobilization using thoracolumbosacral orthosis have been applied for stable compression fractures of the pediatric spine. The aim of this study was to evaluate the influence of bracing on the remodeling capacity of pediatric thoracolumbar type A 1.2 impaction fractures. Additionally, the prevalence of pain and functional disabilities were assessed. METHODS: All children treated conservatively between 2000 and 2011 with impaction fractures of the thoracolumbar spine (A 1.2) were included and re-invited for a clinical [including VAS 0-100, Oswestry disability index (ODI)] and radiological follow-up examination. Changes of the sagittal index (SI) at the time of the accident, the latest control visit and at the follow-up examination were analyzed. RESULTS: Seventy-two patients with a mean age of 12 years (1.8-18 years) and a total number of 133 fractured vertebrae were included. The mean SI at the time of injury was 0.76 (range 0.45-0.94, SD 0.08); 34 patients with 67 fractured vertebrae were included in the follow-up examination after a mean of 7.9 years (2.4-13.1 years). The mean SI of the 67 affected vertebrae at follow-up significantly increased to 0.92 (range 0.74-1, SD 0.06). The initial treatment regimen (brace vs no brace) did not influence the remodeling capacity. More than half of the patients (n = 18, 53 %) complained about occasional back-related pain which was not associated with the remodeling process. The mean ODI was 5.8 (range 0-26, SD 6.6) and the mean VAS of the re-evaluated patients was 87 (range 53-100, SD 14). CONCLUSIONS: A significant remodeling capacity of thoracolumbar vertebral impaction fractures sustained in childhood is demonstrated. Bracing does not seem to influence the long-term outcome of these injuries. More studies have to be performed to define the role of bracing in these fractures.


Asunto(s)
Remodelación Ósea/fisiología , Tirantes , Vértebras Lumbares/lesiones , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/lesiones , Adolescente , Dolor de Espalda/diagnóstico por imagen , Dolor de Espalda/etiología , Niño , Preescolar , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Fracturas por Compresión/cirugía , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/cirugía , Masculino , Dimensión del Dolor/métodos , Radiografía , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología , Vértebras Torácicas/cirugía
13.
Clin Orthop Relat Res ; 474(6): 1422-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26304045

RESUMEN

BACKGROUND: Debate remains over the role of surgical treatment in minimally displaced lateral compression (Young-Burgess, LC, OTA 61-B1/B2) pelvic ring injuries. Lateral compression type 1 (LC1) injuries are defined by an impaction fracture at the sacrum; type 2 (LC2) are defined by a fracture that extends through the posterior iliac wing at the level of the sacroiliac joint. Some believe that operative stabilization of these fractures limits pain and eases mobilization, but to our knowledge there are few controlled studies on the topic. QUESTIONS/PURPOSES: (1) Does operative stabilization of LC1 and LC2 pelvic fractures decrease patients' narcotic use and lower their visual analog scale pain scores? (2) Does stabilization allow patients to mobilize earlier with physical therapy? METHODS: This retrospective study of LC1 and LC2 fractures evaluated patients treated definitively at one institution from 2007 to 2013. All patients treated surgically, all nonoperative LC2, and all nonoperative LC1 fractures with complete sacral injury were included. In general, LC1 or LC2 fractures with greater than 10 mm of displacement and/or sagittal/axial plane deformity on static radiographs were treated surgically. One hundred fifty-eight patients in the LC1 group (107 [of 697 screened] nonoperative, 51 surgical) and 123 patients in the LC2 group (78 nonoperative, 45 surgical) met inclusion criteria. The surgical and nonoperative groups were matched for fracture type. To account for differences between patients treated surgically and nonoperatively, we used propensity modeling techniques incorporating treatment predictors. Propensity scores demonstrated good overlap and were used as part of multiple variable regression models to account for selection bias between the surgically treated and nonoperative groups. Patient-reported pain scores and narcotic administration were tallied in 24-hour increments during the first 24 hours of hospitalization, at 48 hours after intervention, and in the 24 hours before discharge. Time from intervention to mobilization out of bed was recorded; intervention was defined as the date of definitive surgical intervention or the day the surgeon determined the patient would be treated without surgery. RESULTS: There was no difference in the narcotics distributed to any of the groups with the exception that the patients with surgically treated LC2 fractures used, on average (mean [95% confidence interval]) 40.2 (-72.9 to -7.6) mg morphine less at the 48-hour mark (p = 0.016). In general, there were no differences between the groups' pain scores. The surgically treated patients with LC1 fractures mobilized 1.7 (-3.3 to -0.01) days earlier (p = 0.034) than their nonoperative counterparts. There was no difference in the LC2 cohort in terms of time to mobilization between those treated with and without surgery. CONCLUSIONS: There were few differences in pain scores and morphine use between the surgical and nonoperative groups, and the differences observed likely were not clinically important. We found no evidence that surgical stabilization of certain LC1 and LC2 pelvic fractures improves patients' pain, decreases their narcotic use, and improves time to mobilization. A randomized trial of patients with similar fractures and similar degrees initial displacement would help remove some of the confounders present in this study. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Fracturas por Compresión/cirugía , Ilion/cirugía , Morfina/uso terapéutico , Narcóticos/uso terapéutico , Dolor Postoperatorio/prevención & control , Articulación Sacroiliaca/cirugía , Sacro/cirugía , Fracturas de la Columna Vertebral/cirugía , Adulto , Fenómenos Biomecánicos , Femenino , Florida , Fijación Interna de Fracturas/efectos adversos , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Humanos , Ilion/diagnóstico por imagen , Ilion/lesiones , Ilion/fisiopatología , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Puntaje de Propensión , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/lesiones , Articulación Sacroiliaca/fisiopatología , Sacro/diagnóstico por imagen , Sacro/lesiones , Sacro/fisiopatología , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
14.
BMC Musculoskelet Disord ; 17: 134, 2016 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-27005301

RESUMEN

BACKGROUND: Although minimally invasive posterior spine implant systems have been introduced, clinical studies reported on reduced quality of spinal column realignment due to correction loss. The aim of this study was to compare biomechanically two minimally invasive spine stabilization systems versus the Universal Spine Stabilization system (USS). METHODS: Three groups with 5 specimens each and 2 foam bars per specimen were instrumented with USS (Group 1) or a minimally invasive posterior spine stabilization system with either polyaxial (Group 2) or monoaxial (Group 3) screws. Mechanical testing was performed under quasi-static ramp loading in axial compression and torsion, followed by destructive cyclic loading run under axial compression at constant amplitude and then with progressively increasing amplitude until construct failure. Bending construct stiffness, torsional stiffness and cycles to failure were investigated. RESULTS: Initial bending stiffness was highest in Group 3, followed by Group 2 and Group 1, without any significant differences between the groups. A significant increase in bending stiffness after 20'000 cycles was observed in Group 1 (p = 0.002) and Group 2 (p = 0.001), but not in Group 3, though the secondary bending stiffness showed no significant differences between the groups. Initial and secondary torsional stiffness was highest in Group 1, followed by Group 3 and Group 2, with significant differences between all groups (p ≤ 0.047). A significant increase in initial torsional stiffness after 20'000 cycles was observed in Group 2 (p = 0.017) and 3 (p = 0.013), but not in Group 1. The highest number of cycles to failure was detected in Group 1, followed by Group 3 and Group 2. This parameter was significantly different between Group 1 and Group 2 (p = 0.001), between Group 2 and Group 3 (p = 0.002), but not between Group 1 and Group 3. CONCLUSIONS: These findings quantify the correction loss for minimally invasive spine implant systems and imply that unstable spine fractures might benefit from stabilization with conventional implants like the USS.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas por Compresión/cirugía , Inestabilidad de la Articulación/cirugía , Fracturas de la Columna Vertebral/cirugía , Columna Vertebral/cirugía , Fenómenos Biomecánicos , Fracturas por Compresión/fisiopatología , Humanos , Inestabilidad de la Articulación/fisiopatología , Procedimientos Quirúrgicos Mínimamente Invasivos , Modelos Anatómicos , Diseño de Prótesis , Rango del Movimiento Articular , Fracturas de la Columna Vertebral/fisiopatología , Columna Vertebral/fisiopatología
17.
BMC Musculoskelet Disord ; 16: 145, 2015 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-26071690

RESUMEN

BACKGROUND: Percutaneous vertebroplasty (PVP) typically involves conventional lower-viscosity cement injection via bipedicular approach. Limited evidence is available comparing the clinical outcomes and complications in treating osteoporotic vertebral compression fractures (OVCFs) with PVP using high-viscosity cement through unipedicular or bipedicular approach. METHODS AND DESIGN: Fifty patients with OVCFs were randomly allocated into two groups adopting unipedicular or bipedicular PVP. The efficacy of unipedicular and bipedicular PVP was assessed by comparing operation time, X-ray exposure time, incidence of complications, vertebral height restoration, and improvement of the visual analogue scale (VAS), Oswestry disability index (ODI) and Short Form-36 (SF-36) General Health Survey scores. RESULTS: The mean operative and exposure time to X-rays in the unipedicular PVP group was less than that of the bipedicular group (p < 0.05). No statistically significant differences were observed in the VAS score, ODI score, SF-36 score, cement leakage rate or vertebral height restoration between the two groups (p > 0.05). CONCLUSION: Unipedicular and bipedicular PVP are safe and effective treatments for OVCF. Compared with bipedicular PVP, unipedicular PVP entails a shorter surgical time and lower X-ray irradiation.


Asunto(s)
Cementos para Huesos/uso terapéutico , Fracturas por Compresión/cirugía , Fracturas Osteoporóticas/cirugía , Fracturas de la Columna Vertebral/cirugía , Vertebroplastia/métodos , Anciano , Cementos para Huesos/efectos adversos , China , Evaluación de la Discapacidad , Femenino , Curación de Fractura , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/fisiopatología , Estado de Salud , Humanos , Inyecciones Espinales , Masculino , Tempo Operativo , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/fisiopatología , Dimensión del Dolor , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Dosis de Radiación , Radiografía , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento , Vertebroplastia/efectos adversos , Viscosidad
18.
J Spinal Disord Tech ; 28(10): E578-83, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24189482

RESUMEN

STUDY DESIGN: A retrospective cohort study. OBJECTIVE: New vertebral compression fracture (NVCF) is a highly potential risk after percutaneous vertebroplasty (PVP). The study aimed at analyzing the incidence and risk factors of NVCF and preventing its development. SUMMARY OF BACKGROUND DATA: PVP is widely used and highly effective technique for reducing pain caused by an osteoporotic vertebral compression fracture. However, there is a great deal of debate about whether PVP is associated with NVCF, and many risk factors of NVCF have been hypothesized. METHODS: From January to December 2008, a total of 198 patients (176 women, 22 men; mean age, 76.6±0.5 y) who underwent PVP at 270 levels for painful osteoporotic VCF were retrospectively analyzed during a 4-year follow-up. The following parameters were evaluated: NVCF incidence and average time, body mass index (BMI), smoking history, the existence of trauma, and bone mineral density (BMD) before and after PVP. Cement location, intradiscal leakage, distribution pattern, kyphotic angle, sagittal index, compression ratio, injected cement volume, and numbers of fractures and thoracolumbar junction fractures were analyzed. RESULTS: During follow-up, 34 patients (17.2%) sustained symptomatic NVCF for 4-year follow-up. All 34 patients with NVCF had lower BMD than that before initial PVP. For adjacent VCF, multivariable analysis showed that a higher risk of NVCF after vertebroplasty was associated with a larger number of VCF (P=0.025) and lower BMI (P=0.045), whereas for remote VCF, the risk of NVCF was higher in patients who had not experienced trauma and lower BMD (P=0.045). None of the radiographic evaluation values were related to the occurrence of NVCF. CONCLUSIONS: The most important elements related to reducing NVCF were treating osteoporosis and improving BMD and BMI. More aggressive BMD and BMI correction is more important than the vertebroplasty technique.


Asunto(s)
Fracturas por Compresión/etiología , Fracturas por Compresión/cirugía , Fracturas Osteoporóticas/cirugía , Dolor/etiología , Fracturas de la Columna Vertebral/etiología , Fracturas de la Columna Vertebral/cirugía , Vertebroplastia/efectos adversos , Anciano , Anciano de 80 o más Años , Densidad Ósea , Demografía , Femenino , Estudios de Seguimiento , Fracturas por Compresión/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Fracturas Osteoporóticas/fisiopatología , Factores de Riesgo , Fracturas de la Columna Vertebral/fisiopatología
19.
Osteoporos Int ; 25(2): 543-50, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23912556

RESUMEN

UNLABELLED: The Safe Functional Motion test (SFM) was developed to document movement strategies used to perform everyday activities that may increase the risk for osteoporotic fracture. After adjusting for variables known to predict vertebral compression fracture (VCF), baseline score on the SFM was a significant independent predictor of incident VCF at 1- and 3-year follow-ups. INTRODUCTION: Functional movements may contribute to risk for VCF. We hypothesize that scores on the SFM, a performance-based test of physical function, are associated with incident VCF. METHODS: An osteoporosis clinic database was queried for men and women ≥ 50 years with an initial SFM and corresponding data for prevalent VCF, history of injurious falls, femoral neck bone mineral density (fnBMD), osteoporosis medication use, and incident morphometric VCF at 1-year (n = 878) and 3-year follow-ups (n = 503). Multiple logistic regressions, adjusted for gender, age, injurious fall(s), fnBMD, prevalent VCF at baseline, and osteoporosis medication use, were used to determine whether SFM score was associated with incident VCF at follow-up visits. RESULTS: Baseline SFM score was a significant independent predictor of incident VCF at 1-year follow-up (adjusted odds ratio (95 % confidence intervals (CI)) = 0.818 (0.707, 0.948); p < 0.008) and 3-year follow-up (adjusted odds ratio (95 % CI) = 0.728 (0.628, 0.844); p < 0.0001). Baseline fnBMD and osteoporosis medication use were significant predictors at 1-year (p = 0.05 and < 0.0001, respectively) and 3-year (p < 0.01 and 0.001, respectively) follow-ups. At 3-year follow-up, gender and prevalent VCF were also significant predictors (p = 0.003 and 0.007, respectively). CONCLUSIONS: For every 10-point increase in SFM score, the odds of future VCF decreases by 18 % at 1 year and 27 % at 3 years after adjusting for known covariates. The SFM may aid in the identification of modifiable functional risk factors for VCF.


Asunto(s)
Actividades Cotidianas , Fracturas por Compresión/fisiopatología , Fracturas Osteoporóticas/fisiopatología , Fracturas de la Columna Vertebral/fisiopatología , Anciano , Densidad Ósea/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento/fisiología , Fuerza Muscular/fisiología , Equilibrio Postural/fisiología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo/métodos , Soporte de Peso/fisiología
20.
J Obstet Gynaecol Res ; 40(1): 288-92, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24102815

RESUMEN

The syndrome of pregnancy-associated osteoporosis (PAO) is a rare disorder which occurs either in late pregnancy or early post-partum period leading to fragility fracture(s), most commonly in the vertebral bodies. We presented two cases with PAO who had compression fractures at multiple levels involving five vertebrae in one case and 10 vertebrae in the other. Their spinal bone mineral density values were below -2.5 standard deviations. Anti-osteoporotic treatments with nasal calcitonin 400 IU/day, vitamin D 300.000 IU single dose, calcium 1000 mg/day, vitamin D 880 IU/day were initiated. In one case, kyphoplasty was performed by a spinal surgeon. In addition to a thoracolumbosacral orthosis, a rehabilitation program including muscle strengthening, range of motion, relaxation and weight-bearing exercises was started for both cases. These cases emphasize that all pregnant women with complaints of back/lumbar pain should be carefully evaluated.


Asunto(s)
Fracturas por Compresión/etiología , Osteoporosis/fisiopatología , Fracturas Osteoporóticas/etiología , Complicaciones del Embarazo/fisiopatología , Fracturas de la Columna Vertebral/etiología , Adulto , Dolor de Espalda/etiología , Densidad Ósea , Terapia Combinada , Femenino , Fracturas por Compresión/fisiopatología , Fracturas por Compresión/rehabilitación , Fracturas por Compresión/terapia , Humanos , Fracturas Osteoporóticas/fisiopatología , Fracturas Osteoporóticas/rehabilitación , Fracturas Osteoporóticas/terapia , Periodo Posparto , Embarazo , Tercer Trimestre del Embarazo , Índice de Severidad de la Enfermedad , Fracturas de la Columna Vertebral/fisiopatología , Fracturas de la Columna Vertebral/rehabilitación , Fracturas de la Columna Vertebral/terapia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda