Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 10.352
Filtrar
Más filtros

Publication year range
1.
Ophthalmology ; 131(1): 37-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37702635

RESUMEN

PURPOSE: To review the current published literature for high-quality studies on the use of selective laser trabeculoplasty (SLT) for the treatment of glaucoma. This is an update of the Ophthalmic Technology Assessment titled, "Laser Trabeculoplasty for Open-Angle Glaucoma," published in November 2011. METHODS: Literature searches in the PubMed database in March 2020, September 2021, August 2022, and March 2023 yielded 110 articles. The abstracts of these articles were examined to include those written since November 2011 and to exclude reviews and non-English articles. The panel reviewed 47 articles in full text, and 30 were found to fit the inclusion criteria. The panel methodologist assigned a level I rating to 19 studies and a level II rating to 11 studies. RESULTS: Data in the level I studies support the long-term effectiveness of SLT as primary treatment or as a supplemental therapy to glaucoma medications for patients with open-angle glaucoma. Several level I studies also found that SLT and argon laser trabeculoplasty (ALT) are equivalent in terms of safety and long-term efficacy. Level I evidence indicates that perioperative corticosteroid and nonsteroidal anti-inflammatory drug eye drops do not hinder the intraocular pressure (IOP)-lowering effect of SLT treatment. The impact of these eye drops on lowering IOP differed in various studies. No level I or II studies exist that determine the ideal power settings for SLT. CONCLUSIONS: Based on level I evidence, SLT is an effective long-term option for the treatment of open-angle glaucoma and is equivalent to ALT. It can be used as either a primary intervention, a replacement for medication, or an additional therapy with glaucoma medications. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Oftalmología , Trabeculectomía , Humanos , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/cirugía , Rayos Láser , Soluciones Oftálmicas , Malla Trabecular/cirugía , Estados Unidos
2.
Ophthalmology ; 131(2): 227-239, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069945

RESUMEN

PURPOSE: To evaluate the recently published literature on the efficacy and safety of the use of aqueous shunts with extraocular reservoir for the management of adult open-angle glaucomas (OAGs). METHODS: A search of peer-reviewed literature was last conducted in April 2023 of the PubMed database and included only articles published since the last aqueous shunt Ophthalmic Technology Assessment, which assessed articles published before 2008. The abstracts of these 419 articles were examined, and 58 studies were selected for full-text analysis. After inclusion and exclusion criteria were applied, 28 articles were selected and assigned ratings by the panel methodologist according to the level of evidence. Twenty-five articles were rated level I and 3 articles were rated level II. There were no level III articles. RESULTS: Implantation of aqueous shunts with extraocular reservoir can lower intraocular pressure (IOP) by between one-third and one-half of baseline IOP, depending on whether it is undertaken as the primary or secondary glaucoma surgery. Success rates for aqueous shunts were found to be better than for trabeculectomies in eyes with prior incisional surgery. Conversely, in eyes without prior incisional surgery, implantation of aqueous shunts was found to have an overall lower success rate as the primary glaucoma procedure compared with trabeculectomy. Although both valved and nonvalved aqueous shunts with extraocular reservoir were effective, the nonvalved device generally achieved slightly lower long-term IOPs with fewer glaucoma medications and less need for additional glaucoma surgery. Both devices slow the rates of visual field progression with efficacy comparable with that of trabeculectomy. Early aqueous humor suppression after aqueous shunt implantation is recommended for the management of the postoperative hypertensive phase and long-term IOP control. No strong evidence supports the routine use of mitomycin C with aqueous shunt implantation for OAG. CONCLUSIONS: Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP. Strong level I evidence supports the use of aqueous shunts with extraocular reservoir by clinicians for the management of adult OAG. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma , Oftalmología , Trabeculectomía , Adulto , Humanos , Estados Unidos , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Trabeculectomía/métodos , Resultado del Tratamiento
3.
Ophthalmology ; 131(7): 803-814, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38199527

RESUMEN

PURPOSE: Review hypotony failure criteria used in glaucoma surgical outcome studies and evaluate their impact on success rates. DESIGN: Systematic literature review and application of hypotony failure criteria to 2 retrospective cohorts. PARTICIPANTS: A total of 934 eyes and 1765 eyes undergoing trabeculectomy and deep sclerectomy (DS) with a median follow-up of 41.4 and 45.4 months, respectively. METHODS: Literature-based hypotony failure criteria were applied to patient cohorts. Intraocular pressure (IOP)-related success was defined as follows: (A) IOP ≤ 21 mmHg with ≥ 20% IOP reduction; (B) IOP ≤ 18 mmHg with ≥ 20% reduction; (C) IOP ≤ 15 mmHg with ≥ 25% reduction; and (D) IOP ≤ 12 mmHg with ≥ 30% reduction. Failure was defined as IOP exceeding these criteria in 2 consecutive visits > 3 months after surgery, loss of light perception, additional IOP-lowering surgery, or hypotony. Cox regression estimated failure risk for different hypotony criteria, using no hypotony as a reference. Analyses were conducted for each criterion and hypotony type (i.e., numerical [IOP threshold], clinical [clinical manifestations], and mixed [combination of numerical or clinical criteria]). MAIN OUTCOME MEASURES: Hazard ratio (HR) for failure risk. RESULTS: Of 2503 studies found, 278 were eligible, with 99 studies (35.6%) lacking hypotony failure criteria. Numerical hypotony was predominant (157 studies [56.5%]). Few studies used clinical hypotony (3 isolated [1.1%]; 19 combined with low IOP [6.8%]). Forty-nine different criteria were found, with IOP < 6 mmHg, IOP < 6 mmHg on ≥ 2 consecutive visits after 3 months, and IOP < 5 mmHg being the most common (41 [14.7%], 38 [13.7%], and 13 [4.7%] studies, respectively). In both cohorts, numerical hypotony posed the highest risk of failure (HR, 1.51-1.21 for criteria A to D; P < 0.001), followed by mixed hypotony (HR, 1.41-1.20 for criteria A to D; P < 0.001), and clinical hypotony (HR, 1.12-1.04; P < 0.001). Failure risk varied greatly with various hypotony definitions, with the HR ranging from 1.02 to 10.79 for trabeculectomy and 1.00 to 8.36 for DS. CONCLUSIONS: Hypotony failure criteria are highly heterogenous in the glaucoma literature, with few studies focusing on clinical manifestations. Numerical hypotony yields higher failure rates than clinical hypotony and can underestimate glaucoma surgery success rates. Standardizing failure criteria with an emphasis on clinically relevant hypotony manifestations is needed. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Asunto(s)
Glaucoma , Presión Intraocular , Hipotensión Ocular , Tonometría Ocular , Trabeculectomía , Insuficiencia del Tratamiento , Humanos , Presión Intraocular/fisiología , Hipotensión Ocular/fisiopatología , Estudios Retrospectivos , Glaucoma/cirugía , Glaucoma/fisiopatología , Esclerostomía/métodos , Femenino , Estudios de Seguimiento , Masculino , Agudeza Visual/fisiología
4.
Ophthalmology ; 131(3): 266-276, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37769852

RESUMEN

PURPOSE: To compare the effectiveness and safety of the MicroShunt (Santen Inc) versus trabeculectomy in patients with primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, multicenter trial conducted in the United States and Europe. PARTICIPANTS: Adult patients (aged 40-85 years) with mild to severe POAG inadequately controlled on maximum tolerated medical therapy and intraocular pressure (IOP) ≥ 15 mmHg and ≤ 40 mmHg. METHODS: Patients were randomized 3:1 to stand-alone MicroShunt implantation (n = 395) or trabeculectomy (n = 132), both augmented with mitomycin C (MMC) 0.2 mg/ml for 2 minutes. MAIN OUTCOME MEASURES: The primary effectiveness end point was surgical success, defined as ≥ 20% reduction in mean diurnal IOP from baseline with no increase in glaucoma medications. Secondary end points included changes in mean IOP and medication use from baseline and the need for postoperative interventions. RESULTS: At 2 years, the rate of surgical success was lower in the MicroShunt group than in the trabeculectomy group (50.6% vs. 64.4%, P = 0.005). Mean diurnal IOP was reduced from 21.1 ± 4.9 mmHg at baseline to 13.9 ± 3.9 mmHg at 24 months in the MicroShunt group and from 21.1 ± 5.0 mmHg at baseline to 10.7 ± 3.7 mmHg at 24 months in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Mean medication use decreased from 3.1 to 0.9 in the MicroShunt group and from 2.9 to 0.4 in the trabeculectomy group (P < 0.001 compared with baseline in both groups). Adverse events at 2 years were generally similar in the 2 groups, except that hypotony was more common in eyes undergoing trabeculectomy (51.1% vs. 30.9%, P < 0.001). Repositioning or explantation of the implant occurred in 6.8% of MicroShunt patients. The majority of these patients had device removal at the time of subsequent glaucoma surgery. Vision-threatening complications were uncommon in both groups. CONCLUSION: At 2 years, both the MicroShunt and trabeculectomy provided significant reductions in IOP and medication use, with trabeculectomy continuing to have greater surgical success. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Trabeculectomía , Adulto , Humanos , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular , Mitomicina , Estudios Prospectivos , Trabeculectomía/métodos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
5.
Ophthalmology ; 131(7): 780-789, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38246424

RESUMEN

PURPOSE: To evaluate risk factors for intraocular pressure (IOP) spike after cataract surgery using the IRIS® Registry (Intelligent Research in Sight). DESIGN: Retrospective clinical cohort study. PARTICIPANTS: Adults with IRIS Registry data who underwent stand-alone phacoemulsification from January 1, 2013, through September 30, 2019. METHODS: Intraocular pressure spike was defined as postoperative IOP of > 30 mmHg and > 10 mmHg from the baseline within the first postoperative week. Odds ratios (ORs) for demographic and clinical characteristics were calculated with univariable and multivariable logistic regression analyses. MAIN OUTCOME MEASURES: Incidence and OR of IOP spike. RESULTS: We analyzed data from 1 191 034 eyes (patient mean age, 71.3 years; 61.2% female sex; and 24.8% with glaucoma). An IOP spike occurred in 3.7% of all eyes, 5.2% of eyes with glaucoma, and 3.2% of eyes without glaucoma (P < 0.0001). Multivariable analyses of all eyes indicated a greater risk of IOP spike with higher baseline IOP (OR, 1.57 per 3 mmHg), male sex (OR, 1.79), glaucoma (OR, 1.20), Black race (OR, 1.39 vs. Asian and 1.21 vs. Hispanic), older age (OR, 1.07 per 10 years), and complex surgery coding (OR, 1.22; all P < 0.0001). Diabetes (OR, 0.90) and aphakia after surgery (OR, 0.60) seemed to be protective against IOP spike (both P < 0.0001). Compared with glaucoma suspects, ocular hypertension (OR, 1.55), pigmentary glaucoma (OR, 1.56), and pseudoexfoliative glaucoma (OR, 1.52) showed a greater risk of IOP spike and normal-tension glaucoma (OR, 0.55), suspected primary angle closure (PAC; OR, 0.67), and PAC glaucoma (OR, 0.81) showed less risk (all P < 0.0001). Using more baseline glaucoma medications was associated with IOP spike (OR, 1.18 per medication), whereas topical ß-blocker use (OR, 0.68) was protective (both P < 0.0001). CONCLUSIONS: Higher baseline IOP, male sex, glaucoma, Black race, older age, and complex cataract coding were associated with early postoperative IOP spike, whereas diabetes and postoperative aphakia were protective against a spike after stand-alone phacoemulsification. Glaucomatous eyes demonstrated different risk profiles dependent on glaucoma subtype. The findings may help surgeons to stratify and mitigate the risk of IOP spike after cataract surgery. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Presión Intraocular , Facoemulsificación , Sistema de Registros , Humanos , Masculino , Presión Intraocular/fisiología , Femenino , Anciano , Estudios Retrospectivos , Factores de Riesgo , Persona de Mediana Edad , Anciano de 80 o más Años , Tonometría Ocular , Incidencia , Complicaciones Posoperatorias , Implantación de Lentes Intraoculares , Hipertensión Ocular/fisiopatología , Hipertensión Ocular/etiología , Glaucoma/fisiopatología , Glaucoma/cirugía
6.
Ophthalmology ; 131(10): 1157-1163, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38582154

RESUMEN

PURPOSE: To describe visual field outcomes in the Primary Tube Versus Trabeculectomy (PTVT) Study. DESIGN: Cohort analysis. PARTICIPANTS: A total of 155 eyes (155 subjects) randomly assigned to treatment with tube shunt surgery (n = 84) or trabeculectomy with mitomycin C (n = 71). METHODS: The PTVT Study was a multicenter randomized clinical trial comparing the safety and efficacy of trabeculectomy and tube shunt surgery in eyes without previous intraocular surgery. Subjects underwent standard automated perimetry (SAP) at baseline and annually for 5 years. Standard automated perimetry tests were deemed reliable if the false-positive rate was ≤ 15%. Tests were excluded if visual acuity was ≤ 20/400 or loss of ≥ 2 Snellen lines from baseline because of a nonglaucomatous etiology. Linear mixed-effects models were used to compare rates of change in SAP mean deviation (MD) between the 2 groups. Intraocular pressure (IOP) control was assessed by percentage of visits with IOP < 18 mmHg and mean IOP. MAIN OUTCOME MEASURES: Rate of change in SAP MD during follow-up. RESULTS: A total of 730 SAP tests were evaluated (average of 4.7 tests per eye). The average SAP MD at baseline was -12.8 ± 8.3 decibels (dB) in the tube group and -12.0 ± 8.4 dB in the trabeculectomy group (P = 0.57). The mean rate of change in SAP MD was -0.32 ± 0.39 dB/year in the trabeculectomy group and -0.47 ± 0.43 dB/year in the tube group (P = 0.23). Eyes with mean IOP 14 to 17.5 mmHg had significantly faster rates of SAP MD loss compared with eyes with mean IOP < 14 mmHg (-0.59 ± 0.13 vs. -0.27 ± 0.08 dB/year; P = 0.012), and eyes with only 50% to 75% of visits with IOP < 18 mmHg had faster rates than those with 100% of visits with IOP < 18 mmHg (-0.90 ± 0.16 vs. -0.29 ± 0.08 dB/year; P < 0.001). Multivariable analysis identified older age and worse IOP control as risk factors for faster progression in both treatment groups. CONCLUSIONS: No statistically significant difference in mean rates of visual field change was observed between trabeculectomy and tube shunt surgery in the PTVT Study. Worse IOP control was significantly associated with faster rates of SAP MD loss during follow-up. Older patients were also at risk for faster progression. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Implantes de Drenaje de Glaucoma , Presión Intraocular , Mitomicina , Trabeculectomía , Agudeza Visual , Pruebas del Campo Visual , Campos Visuales , Humanos , Trabeculectomía/métodos , Campos Visuales/fisiología , Presión Intraocular/fisiología , Femenino , Masculino , Agudeza Visual/fisiología , Anciano , Persona de Mediana Edad , Mitomicina/administración & dosificación , Alquilantes/administración & dosificación , Resultado del Tratamiento , Tonometría Ocular , Trastornos de la Visión/fisiopatología , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Estudios de Seguimiento , Glaucoma/fisiopatología , Glaucoma/cirugía , Terapia Combinada
7.
Ophthalmology ; 131(2): 179-187, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37709170

RESUMEN

PURPOSE: To determine early endophthalmitis incidence and risk factors after glaucoma surgeries in the Medicare population. DESIGN: Retrospective, longitudinal study. PARTICIPANTS: Medicare Fee-for-Service (FFS) and Medicare Advantage beneficiaries in the United States aged 65 years or older undergoing glaucoma surgery. METHODS: Medicare claims were used to identify all patients who underwent glaucoma, cataract, or combined cataract/glaucoma surgery from 2016 to 2019. Endophthalmitis cases within 42 days of the index surgery were identified using the diagnostic codes. Multivariable logistic regression models were used to evaluate factors associated with postoperative endophthalmitis. MAIN OUTCOME MEASURES: The 42-day postoperative endophthalmitis incidence and risk factors associated with endophthalmitis after glaucoma surgery. RESULTS: There were 466 928 glaucoma surgeries, of which 310 823 (66.6%) were combined with cataract surgery. Cataract surgeries alone (n = 8 460 360) served as a reference group. Microinvasive glaucoma surgeries constituted most glaucoma procedures performed (67.8%), followed by trabeculectomy (14.0%), tube shunt (10.9%), and other procedures (7.3%). There were 572 cases of endophthalmitis identified after all glaucoma surgeries. Endophthalmitis incidence after glaucoma, combined cataract/glaucoma, and cataract surgeries alone was 1.5 (95% confidence interval [CI], 1.3-1.7), 1.1 (95% CI, 1.0-1.2), and 0.8 (95% CI, 0.8-0.8) per 1000 procedures, respectively. The median day of diagnosis of endophthalmitis was later for glaucoma surgeries (16.5 days) compared with combined cataract/glaucoma or cataract surgeries alone (8 and 6 days, respectively). Compared with microinvasive glaucoma surgery (MIGS), tube shunts were the only surgery type to be a significant risk factor for endophthalmitis for both stand-alone (adjusted odds ratio [aOR], 1.8, P = 0.002) and combined surgery (aOR 1.8, P = 0.047). The other risk factor for both stand-alone (aOR 1.1, P = 0.001) and combined (aOR 1.06, P = 0.049) surgeries was the Charlson Comorbidity Index (CCI). Age (aOR 1.03, P = 0.004) and male gender (1.46, P = 0.001) were significant risk factors for combined cataract and glaucoma surgeries. CONCLUSIONS: Compared with cataract surgery, early endophthalmitis incidence was higher for both glaucoma and combined cataract/glaucoma surgeries, with the highest incidence among tube shunts. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Extracción de Catarata , Catarata , Endoftalmitis , Glaucoma , Humanos , Anciano , Masculino , Estados Unidos/epidemiología , Medicare , Estudios Retrospectivos , Incidencia , Estudios Longitudinales , Endoftalmitis/epidemiología , Endoftalmitis/etiología , Endoftalmitis/diagnóstico , Extracción de Catarata/efectos adversos , Factores de Riesgo , Catarata/complicaciones , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Glaucoma/epidemiología , Glaucoma/cirugía , Glaucoma/complicaciones
8.
Curr Opin Ophthalmol ; 35(2): 147-154, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38018796

RESUMEN

PURPOSE OF REVIEW: To review the literature evaluating the effect of cataract surgery on intraocular pressure (IOP) in patients with glaucoma. RECENT FINDINGS: Recent high-quality secondary analyses of large and primary trials continue to show IOP lowering following cataract surgery. Likewise, cataract surgery remains a key treatment for angle closure glaucoma. Some micro-invasive glaucoma surgeries (MIGS) have strong evidence to be performed at the time of cataract surgery. Data clarifying when these surgeries should be combined with cataract surgery is emerging. The mechanism underlying IOP lowering after cataract surgery remains unclear. SUMMARY: Patients who are glaucoma suspects with visually significant cataracts would benefit from cataract surgery alone. Those with mild-moderate damage on 1-2 classes of medications would most likely benefit from additional MIGS. Patients with advanced disease would benefit from cataract surgery and a choice of additional surgery, which depends on disease status and patient factors. Clear lens extraction is becoming a more accepted practice as a primary procedure for patients with angle closure and high IOP or glaucoma. The role of additional MIGS in angle closure needs further study.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma , Cristalino , Facoemulsificación , Humanos , Presión Intraocular , Extracción de Catarata/métodos , Glaucoma/cirugía , Cristalino/cirugía , Catarata/complicaciones , Facoemulsificación/métodos
9.
Curr Opin Ophthalmol ; 35(2): 111-115, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38108372

RESUMEN

PURPOSE OF REVIEW: Rapid innovation in glaucoma surgery is expanding surgical options in the angle, subconjunctival space, and supraciliary space. RECENT FINDINGS: Advancements in glaucoma surgery make it possible for surgeons to provide treatments with less risk. In particular, new devices and lasers are available for minimally invasive glaucoma surgeries. There are also new implants and techniques for bleb-forming glaucoma surgery. SUMMARY: As glaucoma surgeons have access to an increasing number of procedures, devices, and treatments, it is important for evidence to drive decision-making.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Humanos , Glaucoma/cirugía , Procedimientos Quirúrgicos Oftalmológicos/métodos , Conjuntiva/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Presión Intraocular
10.
Curr Opin Ophthalmol ; 35(5): 409-414, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39082111

RESUMEN

PURPOSE OF REVIEW: The advent of minimally invasive glaucoma surgery (MIGS) procedures has ushered in a new era of interventional glaucoma. MIGS has expanded the treatment options for surgeons necessitating a rethinking of the optimal management strategy for patients with glaucoma. RECENT FINDINGS: There are several new MIGS devices and procedures available to glaucoma surgeons. With several options available, patient selection is crucial to maximize the utility of MIGS in the context of traditional glaucoma surgery. SUMMARY: A management algorithm is presented based on our practice pattern to help guide decision-making for glaucoma surgeons. Although we encourage surgeons to continue to broaden their toolkit, we emphasize the continued importance of teaching the next-generation traditional glaucoma surgery in the MIGS era. Future prospective studies are warranted to elucidate the optimal treatment strategy for patients with glaucoma.


Asunto(s)
Glaucoma , Presión Intraocular , Procedimientos Quirúrgicos Mínimamente Invasivos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Glaucoma/cirugía , Presión Intraocular/fisiología , Trabeculectomía/métodos , Cirugía Filtrante/métodos , Implantes de Drenaje de Glaucoma
11.
Biomed Eng Online ; 23(1): 73, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39061069

RESUMEN

BACKGROUND: Minimally invasive glaucoma surgery (MIGS) has experienced a surge in popularity in recent years. Glaucoma micro-stents serve as the foundation for these minimally invasive procedures. Nevertheless, the utilization of these stents still presents certain short-term and long-term complications. This study aims to elucidate the creation of a novel drainage stent implant featuring a diverging channel, produced through microfluidic template processing technology. Additionally, an analysis of the mechanical properties, biocompatibility, and feasibility of implantation is conducted. RESULTS: The stress concentration value of the proposed stent is significantly lower, approximately two to three times smaller, compared to the currently available commercial XEN gel stent. This indicates a stronger resistance to bending in theory. Theoretical calculations further reveal that the initial drainage efficiency of the gradient diverging drainage stent is approximately 5.76 times higher than that of XEN stents. Notably, in vivo experiments conducted at the third month demonstrate a favorable biocompatibility profile without any observed cytotoxicity. Additionally, the drainage stent exhibits excellent material stability in an in vitro simulation environment. CONCLUSIONS: In summary, the diverging drainage stent presents a novel approach to the cost-effective and efficient preparation process of minimally invasive glaucoma surgery (MIGS) devices, offering additional filtering treatment options for glaucoma.


Asunto(s)
Glaucoma , Stents , Glaucoma/cirugía , Animales , Microfluídica/instrumentación , Ensayo de Materiales , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Fenómenos Mecánicos , Diseño de Equipo , Conejos
12.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 927-935, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37843563

RESUMEN

PURPOSE: Intraocular pressure (IOP) spikes (IOP > 30 mmHg or > 10 mmHg above baseline IOP) are a common and worrisome complication of gonioscopy-assisted transluminal trabeculotomy (GATT). The purpose of this study is to identify risk factors for IOP spikes and to describe their characteristics, management, and clinical course in a large cohort of patients. METHODS: A retrospective, single-center study which included 217 consecutive eyes of patients that underwent GATT between December 2019 and April 2022 with follow-up of at least 90 days. RESULTS: IOP spikes occurred in 52 of 217 (24%) eyes. Spikes occurred in 15.5% of patients in whom pre-operative IOP-lowering medications were continued after surgery (90 eyes), and in 29.9% in whom IOP-lowering medications were stopped after surgery (127 eyes). Spikes were diagnosed at a mean of 7.7 ± 6.5 days after surgery. All IOP spikes occurred within the first month of surgery. The mean duration of a spike was 4.9 ± 5.4 days. Management of IOP spikes included adding a mean of 3.13 ± 1.7 groups of glaucoma medications. Thirty-seven (72.5%) eyes were treated with oral carbonic anhydrase inhibitor, 11 (21.6%) were treated with IV mannitol, and anterior chamber paracentesis was performed in 16 (31.4%). Six (11.8%) eyes underwent additional glaucoma surgery to control IOP. Patients that continued their pre-operative IOP-lowering medications after surgery were 2.3 times less likely to develop a spike as compared to patients who discontinued their medications (P = 0.016). Spikes were found to be a risk factor for failure of GATT. CONCLUSIONS: IOP spikes are a common occurrence after GATT. They most commonly appear during the first two post-operative weeks and usually resolve with topical and systemic IOP-lowering treatment. The continuation of IOP-lowering medications after GATT is recommended to lower the risk of IOP spikes.


Asunto(s)
Glaucoma , Trabeculectomía , Humanos , Presión Intraocular , Gonioscopía , Estudios Retrospectivos , Glaucoma/cirugía , Cámara Anterior
13.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 937-948, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37855957

RESUMEN

PURPOSE: To evaluate the efficacy of XEN®-45 gel stent ab interno implantation for medically uncontrolled uveitic glaucoma. METHODS: Retrospective analysis of 25 eyes receiving XEN® gel stent for medically uncontrolled uveitic glaucoma from February 2019 to February 2023 with recording of intraocular pressure (IOP) values, ocular hypotensive medication, requirement for revision or secondary surgery and complications. Prerequisites for XEN® implantation were a clear cornea, an open iridocorneal angle and an unscarred, mobile conjunctiva at the implantation site. Minimum follow-up required for inclusion was 3 months. The primary outcome measure was IOP compared to baseline. Complete and qualified success were defined as final IOP of ≤ 18 mmHg without or with topical antiglaucomatous treatment, respectively. Failure was defined as IOP > 18 mmHg on two consecutive visits, IOP reduction < 20%, persisting complications from hypotony and open conjunctival bleb revision. Further glaucoma surgical intervention was defined as complete failure. RESULTS: Mean preoperative IOP was 35.3 ± 10.9 mmHg on 2.9 ± 0.9 topical antiglaucomatous agents. 19 of 25 patients (76%) received additional oral acetazolamide. 19 eyes were pseudophakic, 5 eyes phakic and 1 aphakic. Early postoperatively, mean IOP reduced to 7.7 ± 3.0 mmHg (75.8% reduction). At final follow-up (mean 17.7 months) mean IOP was 12.0 ± 3.8 mmHg (62.5% reduction) on 0.2 ± 0.6 medications. Six eyes (24%) required bleb revision at mean 28 weeks and therefore were categorized as failure. One eye failed despite bleb revision and restart of topical ocular hypotensive medication. Three other eyes (12%) had IOP spikes with uveitis flare-ups. Transient hypotony complications occurred in 32%. At final follow-up, 18 eyes (72%) achieved complete success and one eye (4%) qualified success. CONCLUSION: The XEN® gel stent effectively reduced IOP in uncontrolled uveitic glaucoma, with 72% complete success. Bleb revision was required in 24%. IOP spikes occurred in 12% despite functioning blebs. Further follow-up is needed to determine long-term outcomes.


Asunto(s)
Glaucoma , Humanos , Estudios Retrospectivos , Glaucoma/etiología , Glaucoma/cirugía , Presión Intraocular , Tonometría Ocular , Conjuntiva , Antihipertensivos/uso terapéutico
14.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2945-2959, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38573349

RESUMEN

PURPOSE: The aim of this study was to define the capability of ChatGPT-4 and Google Gemini in analyzing detailed glaucoma case descriptions and suggesting an accurate surgical plan. METHODS: Retrospective analysis of 60 medical records of surgical glaucoma was divided into "ordinary" (n = 40) and "challenging" (n = 20) scenarios. Case descriptions were entered into ChatGPT and Bard's interfaces with the question "What kind of surgery would you perform?" and repeated three times to analyze the answers' consistency. After collecting the answers, we assessed the level of agreement with the unified opinion of three glaucoma surgeons. Moreover, we graded the quality of the responses with scores from 1 (poor quality) to 5 (excellent quality), according to the Global Quality Score (GQS) and compared the results. RESULTS: ChatGPT surgical choice was consistent with those of glaucoma specialists in 35/60 cases (58%), compared to 19/60 (32%) of Gemini (p = 0.0001). Gemini was not able to complete the task in 16 cases (27%). Trabeculectomy was the most frequent choice for both chatbots (53% and 50% for ChatGPT and Gemini, respectively). In "challenging" cases, ChatGPT agreed with specialists in 9/20 choices (45%), outperforming Google Gemini performances (4/20, 20%). Overall, GQS scores were 3.5 ± 1.2 and 2.1 ± 1.5 for ChatGPT and Gemini (p = 0.002). This difference was even more marked if focusing only on "challenging" cases (1.5 ± 1.4 vs. 3.0 ± 1.5, p = 0.001). CONCLUSION: ChatGPT-4 showed a good analysis performance for glaucoma surgical cases, either ordinary or challenging. On the other side, Google Gemini showed strong limitations in this setting, presenting high rates of unprecise or missed answers.


Asunto(s)
Glaucoma , Humanos , Estudios Retrospectivos , Glaucoma/cirugía , Glaucoma/fisiopatología , Femenino , Masculino , Trabeculectomía/métodos , Presión Intraocular/fisiología , Anciano , Persona de Mediana Edad
15.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 149-160, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37530849

RESUMEN

PURPOSE: To distinguish functioning from failed filtration blebs (FBs) implementing a deep learning (DL) model on slit-lamp images. METHODS: Retrospective, cross-sectional, multicenter study for development and validation of an artificial intelligence classification algorithm. The dataset consisted of 119 post-trabeculectomy FB images of whom we were aware of the surgical outcome. The ground truth labels were annotated and images splitted into three outcome classes: complete (C) or qualified success (Q), and failure (F). Images were prepared implementing various data cleaning and data transformations techniques. A set of DL models were trained using different ResNet architectures as the backbone. Transfer and ensemble learning were then applied to obtain a final combined model. Accuracy, sensitivity, specificity, area under the ROC curve, and area under the precision-recall curve were calculated to evaluate the final model. Kappa coefficient and P value on the accuracy measure were used to prove the statistical significance level. RESULTS: The DL approach reached good results in unraveling FB functionality. Overall, the model accuracy reached a score of 74%, with a sensitivity of 74% and a specificity of 87%. The area under the ROC curve was 0.8, whereas the area under the precision-recall curve was 0.74. The P value was equal to 0.00307, and the Kappa coefficient was 0.58. CONCLUSIONS: All considered metrics supported that the final DL model was able to discriminate functioning from failed FBs, with good accuracy. This approach could support clinicians in the patients' management after glaucoma surgery in absence of adjunctive clinical data.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Trabeculectomía , Humanos , Presión Intraocular , Estudios Retrospectivos , Inteligencia Artificial , Estudios Transversales , Trabeculectomía/métodos , Glaucoma/diagnóstico , Glaucoma/cirugía
16.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 191-201, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37624385

RESUMEN

PURPOSE: To investigate the postoperative intraocular pressure (IOP) control and identify the factors associated with failure of initial Ex-PRESS surgery in patients with open-angle glaucoma for 3 years. METHODS: A total of 79 patients with medically uncontrolled open-angle glaucoma (55 normal-tension glaucoma and 24 primary open-angle glaucoma) were enrolled. All patients underwent Ex-PRESS implantation (including combined cataract surgery). The outcome measure was the survival rate using life table analysis, the failure was defined as IOP of > 18 mmHg (criterion A), > 15 mmHg (criterion B) or > 12 mmHg (criterion C) and/or IOP reduction of < 20% from baseline (each criterion) without any glaucoma medications. The Cox proportional hazards model was used to identify risk factors for IOP management defined as the above criterion.  RESULTS: The mean preoperative IOP was 19.3 ± 5.8 mmHg. At 36 months, the mean IOP was 11.8 ± 3.6 mmHg with a mean IOP change of 7.5 mmHg (reduction rate 39.0%). The cumulative probability of success was 58% (95%CI: 42-64%) (criterion A), 48% (95%CI: 37-59%) (criterion B) and 30% (95%CI: 20-40%) (criterion C). In multivariate analyses, factors that predicted poor IOP control included the intervention of bleb needling after 6 months after the surgery (HR: 2.43; 95%CI: 1.35-4.37; P = 0.032). Transient hypotony was observed in 4 patients. CONCLUSION: The implementation of bleb needling after Ex-PRESS surgery in the late postoperative period was suggested to be the main risk factor for achieving lower IOP.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma , Glaucoma de Baja Tensión , Trabeculectomía , Humanos , Presión Intraocular , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/complicaciones , Estudios de Seguimiento , Glaucoma/cirugía , Glaucoma de Baja Tensión/diagnóstico , Glaucoma de Baja Tensión/cirugía , Glaucoma de Baja Tensión/complicaciones , Drenaje , Resultado del Tratamiento
17.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 545-556, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37776338

RESUMEN

PURPOSE: This study aimed to report on glaucoma patients' beliefs and illness perceptions and to investigate their opinion on ocular drug delivery devices (ODD). METHODS: We performed a cross-sectional study in a large tertiary-referral outpatient glaucoma clinic, with 102 patients. Validated anonymized questionnaires were used. We investigated the awareness and acceptance regarding ODD (contact lenses (CLs), punctal plugs (PPs), subconjunctival implants, anterior chamber (AC) injections, and drug-emitting stents) and looked at factors that could influence a patient's decision for having an ODD. RESULTS: Sixty-three patients (61.8%) confirmed they would rather have ODD than keep their eye-drops (38.2%). The most important factors influencing their decision were effectiveness and long-lasting effect. A large proportion of patients reported a preference for CLs (48.0%), PPs (52.9%), or drug-emitting stents (44.1%). When comparing patients who preferred ODD (group-1) versus eye-drops (group-2), significantly more patients in group-1 were worried (p < 0.001) or felt disrupted (p < 0.001) by their use of eye-drops. A significantly greater share of patients in group-1 showed acceptance towards CLs (60.3% vs. 38.5%; p = 0.032), AC injections (38.1% vs. 12.8%, p = 0.006), or drug-emitting stents (54% vs. 28.2%, p = 0.023), whilst there were no significant differences regarding the acceptance of PPs (p = 0.363) or subconjunctival implants (p = 0.058). CONCLUSION: ODD for the treatment of glaucoma were broadly deemed acceptable by patients in this study. Effectiveness and long-lasting effect were the most important factors for a decision towards having an ODD. The majority of patients who preferred an ODD felt severely affected by their disease and were negatively influenced by their glaucoma medication intake.


Asunto(s)
Glaucoma , Presión Intraocular , Humanos , Estudios Transversales , Aceptación de la Atención de Salud , Glaucoma/tratamiento farmacológico , Glaucoma/cirugía , Sistemas de Liberación de Medicamentos , Encuestas y Cuestionarios , Soluciones Oftálmicas , Hospitales , Antihipertensivos/uso terapéutico
18.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2209-2217, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38372751

RESUMEN

PURPOSE: To evaluate the outcomes of postoperative aqueous misdirection and factors predicting failure of interventions. METHODS: This retrospective study included 49 eyes from 47 patients with aqueous misdirection following glaucoma or cataract surgery. Resolution of aqueous misdirection (AM) was deepening of the central anterior chamber (AC) and intraocular pressure (IOP) ≤ 21 mmHg. The Cox proportional hazards regression model was used to evaluate risk factors for failure of various treatments. RESULTS: 10/49 eyes (20%) resolved with conservative management, and 39/49 eyes (80%) needed multiple intervention, of which 95% (37/39) eyes achieved resolution of aqueous misdirection. Pseudophakia predicted the need for multiple interventions with a hazard ratio of 2.391 (1.158-4.935), p = 0.02). Among the risk factors assessed for resolution of AM, longer axial length (HR: 0.61 (0.414-0.891), p < 0.01) and eyes with prior glaucoma surgery predicted resolution (HR: 0.142 (0.027-0.741), p < 0.01) and delayed presentation predicted failure (HR: 1.002 (1.0002-1.0031), p < 0.02). CONCLUSION: Pseudophakic eyes were more refractory and predicted the need for multiple interventions. Eyes with prior glaucoma surgery and those with longer axial length had achieved resolution faster, and delayed presentation was a risk factor for failure to resolve.


Asunto(s)
Humor Acuoso , Presión Intraocular , Insuficiencia del Tratamiento , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Presión Intraocular/fisiología , Factores de Riesgo , Anciano , Agudeza Visual/fisiología , Persona de Mediana Edad , Humor Acuoso/metabolismo , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Glaucoma/cirugía , Glaucoma/terapia , Glaucoma/etiología , Complicaciones Posoperatorias , Estudios de Seguimiento , Extracción de Catarata , Anciano de 80 o más Años , Síndrome , Cámara Anterior/patología
19.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2845-2850, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38578333

RESUMEN

PURPOSE: This study aimed to evaluate changes in intraocular pressure following intravitreal dexamethasone implant injection, specifically in patients undergoing glaucoma filtration surgery. METHODS: The degree of increase in intraocular pressure was compared retrospectively among three groups. Group 1 comprised patients who underwent prior glaucoma filtration surgery (54 eyes). Group 2 included patients with or suspected glaucoma without such surgical history (20 eyes). Group 3 included patients without glaucoma (33 eyes). Pressure measurements were taken before the injection and at 1, 2, 3, and 6 months post-injection. A subgroup analysis was performed for pressure > 35 mmHg, > 30 mmHg, > 25 mmHg, and a difference > 10 mmHg between the peak and baseline pressure. RESULTS: Group 1 consistently displayed lower pressures compared with Group 2, with significant difference at both 1- and 6-month post-injections (15.09 mmHg vs. 18.10 mmHg, P = 0.042 and 13.91 mg vs. 17.25 mmHg, P = 0.040). The proportion of patients in Group 1 and Group 3 with pressures > 25 mmHg, > 30 mmHg, and a difference > 10 mmHg did not significantly differ (15.6% vs. 9.5%, P = 0.231; 3.1% vs. 2.3%, P = 0.867; and 17.1% vs. 7.1%, P = 0.231). Notably, Group 2 exhibited a significantly higher proportion within each category (> 25 mmHg, 24.0%; > 30 mmHg, 20.0%; > 10 mmHg difference, 28.0%). CONCLUSION: Intravitreal dexamethasone implant did not increase the risk of elevated intraocular pressure in patients with a history of glaucoma filtration surgery compared with patients with suspected glaucoma; the risk was similar to those without glaucoma.


Asunto(s)
Dexametasona , Implantes de Medicamentos , Cirugía Filtrante , Glaucoma , Glucocorticoides , Presión Intraocular , Inyecciones Intravítreas , Humanos , Dexametasona/administración & dosificación , Presión Intraocular/fisiología , Presión Intraocular/efectos de los fármacos , Estudios Retrospectivos , Glucocorticoides/administración & dosificación , Femenino , Masculino , Anciano , Cirugía Filtrante/métodos , Glaucoma/cirugía , Glaucoma/fisiopatología , Estudios de Seguimiento , Persona de Mediana Edad , Tonometría Ocular , Agudeza Visual
20.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1245-1252, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37938376

RESUMEN

PURPOSE: To evaluate the anterior segment structures using ultrasound biomicroscopy (UBM) in primary congenital glaucoma (PCG) and explore their correlation with disease severity and surgical outcomes. METHODS: Clinical information of PCG patients who underwent UBM prior to their first glaucoma surgeries from September 2014 to March 2021 were reviewed. The study included 214 UBM images of 154 PCG eyes and 60 fellow unaffected eyes. Anterior segment characteristics were analyzed. UBM parameters, including the iris thickness (IT) at variant distances from the pupil edge and iris root, anterior chamber depth (ACD), and pupil diameter (PD), were compared between two groups and their relationship with clinical factors and surgical outcomes were analyzed in PCG eyes. RESULTS: PCG eyes had unclear scleral spur, thin iris, wide anterior chamber angle, deep anterior chamber, rarefied ciliary body, elongated ciliary processes, and abnormal anterior iris insertion. ITs were thinner, ACD was deeper, and PD was larger in PCG eyes than fellow unaffected eyes (all P < 0.001). In PCG eyes, thinner ITs correlated with bilateral involvement and earlier age at presentation, and larger PD correlated with earlier age at presentation (P = 0.030) and higher intraocular pressure (P < 0.001). Thinner IT2 (P = 0.046) and larger PD (P = 0.049) were identified as risk factors for surgical failure. CONCLUSION: UBM is a powerful technique to exam anterior segment structures in PCG. The anatomical features are associated with disease severity and surgical outcomes, providing essential clinical insights.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma , Humanos , Microscopía Acústica/métodos , Cuerpo Ciliar/diagnóstico por imagen , Iris/diagnóstico por imagen , Glaucoma/diagnóstico , Glaucoma/cirugía , Glaucoma/congénito , Gravedad del Paciente , Resultado del Tratamiento , Glaucoma de Ángulo Cerrado/cirugía , Segmento Anterior del Ojo/diagnóstico por imagen , Presión Intraocular
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda