Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Wound Repair Regen ; 24(6): 1073-1080, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27733016

RESUMEN

Lower limb ischemia in diabetic patients is a result of macro- and microcirculation dysfunction. Diabetic patients undergoing limb amputation carry high mortality and morbidity rates, and decision making concerning the level of amputation is critical. Aim of this study is to evaluate a novel microdialysis technique to monitor tissue microcirculation preoperatively and predict the success of limb amputation in such patients. Overall, 165 patients with type 2 diabetes mellitus undergoing lower limb amputation were enrolled. A microdialysis catheter was placed preoperatively at the level of the intended flap for the stump reconstruction, and the levels of glucose, glycerol, lactate and pyruvate were measured for 24 consecutive hours. Patients were then amputated and monitored for 30 days regarding the outcome of amputation. Failure of amputation was defined as delayed healing or stump ischemia. Patients were divided into two groups based on the success of amputation. There was no difference between the two groups regarding gender, ASA score, body mass index, comorbidities, diagnostic modality used, level of amputation, as well as glucose, glycerol, and pyruvate levels. However, local concentrations of lactate were significantly different between the two groups and lactate/pyruvate (L/P) ratio was independently associated with failed amputation (threshold defined at 25.35). Elevated preoperative tissue L/P ratio is independently associated with worse outcomes in diabetic patients undergoing limb amputation. Therefore, preoperative tissue L/P ratio could be used as a predicting tool for limb amputation's outcome, although more clinical data are needed to provide safer conclusions.


Asunto(s)
Amputación Quirúrgica , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Angiopatías Diabéticas/fisiopatología , Isquemia/cirugía , Microdiálisis , Anciano , Anciano de 80 o más Años , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Angiopatías Diabéticas/cirugía , Femenino , Estudios de Seguimiento , Humanos , Isquemia/fisiopatología , Extremidad Inferior , Masculino , Microcirculación/fisiología , Microdiálisis/tendencias , Valor Predictivo de las Pruebas , Procedimientos de Cirugía Plástica
2.
Crit Care ; 18(6): 641, 2014 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-25475018

RESUMEN

INTRODUCTION: Recent experimental and clinical studies have indicated the cardioprotective role of sildenafil during ischemia/reperfusion injury. The aim of this study was to determine, by obtaining metabolic evidence from microdialysis, if sildenafil could reduce the severity of postresuscitation myocardial dysfunction and lead to cardioprotection through beneficial effects on energy metabolism. METHODS: Twenty-four male piglets were randomly divided into three groups: sildenafil (n = 8), saline (SA; n = 8) and sham operation (n = 8). Sildenafil pretreatment consisted of 0.5 mg/kg sildenafil administered once intraperitoneally 30 minutes prior to ventricular fibrillation (VF). The myocardial interstitial fluid (ISF) concentrations of glucose, lactate, pyruvate, glutamate and glycerol were determined by microdialysis before VF. Afterward, the piglets were subjected to 8 minutes of untreated VF followed by 15 minutes of open-chest cardiopulmonary resuscitation. ISF was collected continuously, and the experiment was terminated 24 hours after resuscitation. RESULTS: After 8 minutes of untreated VF, the sildenafil group exhibited higher glucose and pyruvate concentrations of ISF and lower lactate and glutamate levels in comparison with the SA group, and these data reached statistical significance (P < 0.05). Advanced cardiac life support was delivered to both groups, with a 24-hour survival rate showing a promising trend in the sildenafil group (7 of 8 versus 3 of 8 survivors, P < 0.05). Compared with the SA group, the sildenafil group had a better outcome in terms of hemodynamic and oxygen metabolism parameters (P < 0.05). Myocardial tissue analysis revealed a dramatic increase in the contents of ATP, ADP and phosphocreatine in the sildenafil group versus the SA group at 24 hours after return of spontaneous circulation (ROSC; P = 0.03, P = 0.02 and P = 0.02, respectively). Furthermore, 24 hours after ROSC, the sildenafil group had marked elevations in activity of left ventricular Na(+)-K(+)-ATPase and Ca(2+)-ATPase compared with the SA group (P = 0.03, P = 0.04, respectively). CONCLUSIONS: Sildenafil could reduce the severity of postresuscitation myocardial dysfunction, and it produced better clearance of metabolic waste in the ISF. This work might provide insights into the development of a novel strategy to treat postresuscitation myocardial dysfunction.


Asunto(s)
Reanimación Cardiopulmonar/tendencias , Paro Cardíaco/metabolismo , Paro Cardíaco/prevención & control , Microdiálisis/tendencias , Inhibidores de Fosfodiesterasa 5/uso terapéutico , Piperazinas/uso terapéutico , Sulfonamidas/uso terapéutico , Animales , Animales Recién Nacidos , Paro Cardíaco/terapia , Masculino , Metabolismo/efectos de los fármacos , Metabolismo/fisiología , Inhibidores de Fosfodiesterasa 5/farmacología , Piperazinas/farmacología , Purinas/farmacología , Purinas/uso terapéutico , Citrato de Sildenafil , Sulfonamidas/farmacología , Porcinos
3.
World Neurosurg ; 187: e620-e628, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38679378

RESUMEN

OBJECTIVE: The local effects of an intracerebral hemorrhage (ICH) on surrounding brain tissue can be detected bedside using multimodal brain monitoring techniques. The aim of this study is to design a gradient boosting regression model using the R package boostmtree with the ability to predict lactate-pyruvate ratio measurements in ICH. METHODS: We performed a retrospective analysis of 6 spontaneous ICH and 6 traumatic ICH patients who underwent surgical removal of the clot with microdialysis catheters placed in the perihematomal zone. Predictors of glucose, lactate, pyruvate, age, sex, diagnosis, and operation status were used to design our model. RESULTS: In a holdout analysis, the model forecasted lactate-pyruvate ratio trends in a representative in-sample testing set. We anticipate that boostmtree could be applied to designs of similar regression models to analyze trends in other multimodal monitoring features across other types of acute brain injury. CONCLUSIONS: The model successfully predicted hourly lactate-pyruvate ratios in spontaneous ICH and traumatic ICH cases after the hemorrhage evacuation and displayed significantly better performance than linear models. Our results suggest that boostmtree may be a powerful tool in developing more advanced mathematical models to assess other multimodal monitoring parameters for cases in which the perihematomal environment is monitored.


Asunto(s)
Hemorragia Cerebral , Ácido Láctico , Ácido Pirúvico , Humanos , Hemorragia Cerebral/diagnóstico , Estudios Retrospectivos , Ácido Láctico/metabolismo , Masculino , Femenino , Ácido Pirúvico/metabolismo , Persona de Mediana Edad , Anciano , Algoritmos , Microdiálisis/métodos , Microdiálisis/tendencias , Adulto , Anciano de 80 o más Años
4.
Anal Bioanal Chem ; 397(3): 909-16, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20237915

RESUMEN

The need for fast and continuous measurements in the biomedical field is driving scientists to look for an alternative to blood sampling. This implies the adoption of invasive approaches, which, in some cases, may lead to reduced safety for the patient; consequently this strategy is pursued only if it is unavoidable. Microdialysis-based sensing provides a minimally invasive solution, with biological samples drawn by means of a microdialysis catheter and examined outside the human body. Therefore, it has become a promising approach to investigate the interstitial fluid in human brain and subcutaneous adipose tissue, providing important information on the tissue biochemistry and metabolism. Advantages and limitations of microdialysis are considered here and the applications in the clinical field are described, with the provision of some examples and with a view to the new perspectives in the field.


Asunto(s)
Microdiálisis/instrumentación , Microdiálisis/tendencias , Sistemas de Atención de Punto/tendencias , Tejido Adiposo/metabolismo , Animales , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/tendencias , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/tendencias , Dióxido de Carbono/metabolismo , Diseño de Equipo , Humanos , Oxígeno/metabolismo
5.
Skin Pharmacol Physiol ; 23(5): 225-43, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20484965

RESUMEN

Microdialysis (MD) in the skin is a unique technique for in vivo sampling of topically as well as systemically administered drugs at the site of action, e.g. sampling the unbound tissue concentrations in the dermis and subcutaneous tissue. MD as a research method has undergone significant development, improvement and validation during the last decade and has proved to be a versatile, safe and valuable tool for pharmacokinetic and pharmacodynamic studies. This review gives an overview of the current state and future perspectives of dermal MD sampling. Methodological issues such as choice of instrumentation, calibration and experimental procedures are discussed along with the analytical considerations necessary for successful sampling. Clinical MD studies in the skin are reviewed with emphasis on pharmacokinetic studies of topically applied drugs with or without impairment of skin barrier function by skin disease or barrier perturbation. A comparison between MD and other tissue sampling techniques reveals the advantages and limitations of the method. Subsequently, an in-depth discussion of the application of MD for the evaluation of bioavailability and bioequivalence of topical formulations is concluded by the current regulatory point of view. The future perspective includes further expansion and validation of the use of MD in the experimental and clinical setting as well as in the optimization of the method for regulatory purposes, i.e. the commercialization of bioequivalent, generic drug products.


Asunto(s)
Microdiálisis/métodos , Preparaciones Farmacéuticas/administración & dosificación , Absorción Cutánea , Administración Cutánea , Animales , Disponibilidad Biológica , Humanos , Microdiálisis/tendencias , Preparaciones Farmacéuticas/metabolismo , Piel/metabolismo , Equivalencia Terapéutica
6.
Artículo en Alemán | MEDLINE | ID: mdl-19367530

RESUMEN

Cerebral microdialysis (CMD) is a minimal-invasive monitoring technique for patients with subarachnoidal haemorrhage or severe traumatic brain injury, which allows the investigation of a wide spectrum of compounds in the brain tissue. The aim is a precocious identification of cerebral ischemia and secondary brain damage. The method was introduced in the early 1970s. By using commercial equipment it is nowadays possible to conduct on-line analysis at the bedside in the intensive care unit. The following article discusses the principles of CMD, the most commonly used biomarkers and the options during neurointensive care.


Asunto(s)
Lesiones Encefálicas/diagnóstico , Lesiones Encefálicas/metabolismo , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/metabolismo , Encéfalo/metabolismo , Cuidados Críticos/métodos , Microdiálisis/instrumentación , Microdiálisis/métodos , Humanos , Microdiálisis/tendencias
7.
Zhongguo Zhong Yao Za Zhi ; 34(3): 247-50, 2009 Feb.
Artículo en Zh | MEDLINE | ID: mdl-19445140

RESUMEN

Recent publications are quoted to summarize multiple use of microdialysis in medical fields, especially in pharmacology and pharmacokinetics. Microdialysis was coupled with HPLC-ECD, HPLC-MS and other detectors to study endogenous substances and medicines, including neurotransmitters, amino acid, other endogenous metabolites and drugs as well as Chinese medicines. Microdialysis is a relatively new sampling technique and its advantages as well as disadvantages are briefly assessed. At the end of this review, an outlook to apply this technique in traditional Chinese medicine study is given forward.


Asunto(s)
Microdiálisis/métodos , Microdiálisis/tendencias , Preparaciones Farmacéuticas/análisis , Aminoácidos/análisis , Cromatografía Líquida de Alta Presión/métodos , Humanos , Medicina Tradicional China/métodos , Neurotransmisores/análisis
8.
J Agric Food Chem ; 67(8): 2120-2126, 2019 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-30724065

RESUMEN

Endogenous substances, naturally occurring in living organisms, are critical components with physiological and biological functions. Discovery and quantitative measurement of endogenous substances in living biotas are important for food analysis, crop cultivation, and quality assessment. Low or non-invasive in vivo sampling techniques offer the advantages of minimal perturbation to the investigated system and potentially obtain more accurate feedback compared to in vitro sampling. In this perspective, we summarize the up-to-date progress in the development of microdialysis and solid-phase microextraction as valuable tools for in vivo sampling of endogenous substances in food and agriculture chemistry. We discuss their feasibility for on-site and real-time in vivo monitoring and highlight the prospects in searching for highly specific coatings, miniaturized sampling devices, and instruments that well meet the trend for high-efficient and high-throughput analyses.


Asunto(s)
Microdiálisis/métodos , Microextracción en Fase Sólida/métodos , Animales , Biomarcadores/análisis , Biomarcadores/sangre , Humanos , Microdiálisis/tendencias , Microextracción en Fase Sólida/tendencias
9.
ACS Chem Neurosci ; 10(4): 1875-1883, 2019 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-30001105

RESUMEN

Epilepsy is a common neurological disease characterized by recurrent unpredictable seizures. For the last 30 years, microdialysis sampling has been used to measure changes in excitatory and inhibitory neurotransmitter concentrations before, during, and after seizures. These advances have fostered breakthroughs in epilepsy research by identifying neurochemical changes associated with seizures and correlating them to electrophysiological data. Recent advances in methodology may be useful in further delineating the chemical underpinnings of seizures. A new model of ictogenesis has been developed that allows greater control over the timing of seizures that are similar to spontaneous seizures. This model will facilitate making chemical measurements before and during a seizure. Recent advancements in microdialysis sampling, including the use of segmented flow, "fast" liquid chromatography (LC), and capillary electrophoresis with laser-induced fluorescence (CE-LIF) have significantly improved temporal resolution to better than 1 min, which could be used to measure transient, spontaneous neurochemical changes associated with seizures. Microfabricated sampling probes that are markedly smaller than conventional probes and allow for a much greater spatial resolution have been developed. They may allow the targeting of specific brain regions important to epilepsy studies. Coupling microdialysis sampling to optogenetics and light-stimulated release of neurotransmitters may also prove useful for studying epileptic seizures.


Asunto(s)
Encéfalo/metabolismo , Epilepsia/metabolismo , Microdiálisis/métodos , Microdiálisis/tendencias , Neurotransmisores/metabolismo , Animales , Cromatografía Liquida/métodos , Cromatografía Liquida/tendencias , Electroforesis Capilar/métodos , Electroforesis Capilar/tendencias , Epilepsia/diagnóstico , Predicción , Ácido Glutámico/análisis , Ácido Glutámico/metabolismo , Histamina/análisis , Histamina/metabolismo , Humanos , Neurotransmisores/análisis , Espectrometría de Fluorescencia/métodos , Espectrometría de Fluorescencia/tendencias , Ácido gamma-Aminobutírico/análisis , Ácido gamma-Aminobutírico/metabolismo
10.
J Clin Pharmacol ; 48(3): 351-64, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18285620

RESUMEN

Traditionally, plasma or serum drug concentrations have been used for the assessment of bioavailability and bioequivalence. Since in the majority of cases the site of drug action is in the tissue rather than the blood, the use of corresponding free, unbound concentrations in the tissue is a much more meaningful approach. This can become especially important for topical drug administrations, where locally active drug concentrations can significantly exceed free concentrations in plasma. The ability to measure these free concentrations at the site of drug action over time makes microdialysis a very valuable tool for the assessment of bioavailability and bioequivalence. This has been recognized by industry and regulatory authorities, resulting in a recommendation of the microdialysis technique as a tool for bioequivalence determination of topical dermatologic products. The aim of this article is to provide an updated review of the microdialysis technique, its applications in skin and soft tissues, and the resulting impact on clinical drug development.


Asunto(s)
Fármacos Dermatológicos/farmacocinética , Microdiálisis/métodos , Sistema Musculoesquelético/metabolismo , Piel/metabolismo , Administración Tópica , Animales , Disponibilidad Biológica , Fármacos Dermatológicos/administración & dosificación , Humanos , Microdiálisis/normas , Microdiálisis/tendencias , Músculo Esquelético/metabolismo , Equivalencia Terapéutica
11.
Biosens Bioelectron ; 22(3): 449-57, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16797961

RESUMEN

Microdialysis sampling is a diffusion-based separation method that allows analytes to freely diffuse across a hollow fiber semi-permeable dialysis membrane. This sampling technique has been widely used for in vivo chemical collection. The inclusion of affinity-based trapping agents into the microdialysis perfusion fluid serves to improve the relative recovery via the binding reaction of low molecular weight hydrophobic analytes and larger analytes such as peptides and proteins. Here, we briefly review our past studies using different compounds (native cyclodextrins and antibodies) to improve microdialysis sampling recovery. A brief compilation of our studies using antibody-immobilized beads as a means to improve cytokine collection during microdialysis sampling is also described. We present new work focused on the use of antibody-immobilized bead microdialysis sampling enhancement for various endocrine hormones (amylin, GLP-1, glucagon, insulin, and leptin). The antibody-bead enhancement approach allowed for recovery enhancements that ranged between 3 and 20-fold for these peptides. Using the enhanced recovery approach, endocrine peptides at pM concentrations can be quantified. Finally, our initial work focused on developing non-antibody based enhancement agents using bovine serum albumin-heparin conjugates covalently bound to polystyrene microspheres is presented for the cytokine, tumor necrosis factor-alpha (TNF-alpha). Unlike antibodies, heparin provides the advantage of being reusable as an enhancement agent and served to improve the relative recovery of TNF-alpha by three-fold.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas Biosensibles/tendencias , Inmunoensayo/métodos , Inmunoensayo/tendencias , Microdiálisis/métodos , Microdiálisis/tendencias , Predicción
12.
J Neurotrauma ; 22(1): 3-41, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15665601

RESUMEN

Microdialysis (MD) was introduced as an intracerebral sampling method for clinical neurosurgery by Hillered et al. and Meyerson et al. in 1990. Since then MD has been embraced as a research tool to measure the neurochemistry of acute human brain injury and epilepsy. In general investigators have focused their attention to relative chemical changes during neurointensive care, operative procedures, and epileptic seizure activity. This initial excitement surrounding this technology has subsided over the years due to concerns about the amount of tissue sampled and the complicated issues related to quantification. The interpretation of mild to moderate MD fluctuations in general remains an issue relating to dynamic changes of the architecture and size of the interstitial space, blood-brain barrier (BBB) function, and analytical imprecision, calling for additional validation studies and new methods to control for in vivo recovery variations. Consequently, the use of this methodology to influence clinical decisions regarding the care of patients has been restricted to a few institutions. Clinical studies have provided ample evidence that intracerebral MD monitoring is useful for the detection of overt adverse neurochemical conditions involving hypoxia/ischemia and seizure activity in subarachnoid hemorrhage (SAH), traumatic brain injury (TBI), thromboembolic stroke, and epilepsy. There is some data strongly suggesting that MD changes precede the onset of secondary neurological deterioration following SAH, hemispheric stroke, and surges of increased ICP in fulminant hepatic failure. These promising investigations have relied on MD-markers for disturbed glucose metabolism (glucose, lactate, and pyruvate) and amino acids. Others have focused on trying to capture other important neurochemical events, such as excitotoxicity, cell membrane degradation, reactive oxygen species (ROS) and nitric oxide (NO) formation, cellular edema, and BBB dysfunction. However, these other applications need additional validation. Although these cerebral events and their corresponding changes in neurochemistry are important, other promising MD applications, as yet less explored, comprise local neurochemical provocations, drug penetration to the human brain, MD as a tool in clinical drug trials, and for studying the proteomics of acute human brain injury. Nevertheless, MD has provided new important insights into the neurochemistry of acute human brain injury. It remains one of very few methods for neurochemical measurements in the interstitial compartment of the human brain and will continue to be a valuable translational research tool for the future. Therefore, this technology has the potential of becoming an established part of multimodality neuro-ICU monitoring, contributing unique information about the acute brain injury process. However, in order to reach this stage, several issues related to quantification and bedside presentation of MD data, implantation strategies, and quality assurance need to be resolved. The future success of MD as a diagnostic tool in clinical neurosurgery depends heavily on the choice of biomarkers, their sensitivity, specificity, and predictive value for secondary neurochemical events, and the availability of practical bedside methods for chemical analysis of the individual markers. The purpose of this review was to summarize the results of clinical studies using cerebral MD in neurosurgical patients and to discuss the current status of MD as a potential method for use in clinical decision-making. The approach was to focus on adverse neurochemical conditions in the injured human brain and the MD biomarkers used to study those events. Methodological issues that appeared critical for the future success of MD as a routine intracerebral sampling method were addressed.


Asunto(s)
Biomarcadores/metabolismo , Encéfalo/metabolismo , Microdiálisis/tendencias , Encéfalo/cirugía , Lesiones Encefálicas/metabolismo , Lesiones Encefálicas/cirugía , Humanos , Procedimientos Neuroquirúrgicos/tendencias
13.
Biosens Bioelectron ; 20(10): 1897-902, 2005 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-15741056

RESUMEN

Glucose monitoring is an essential component of modern diabetes management. Three in vivo glucose sensors are now available for clinical use: a subcutaneously implanted amperometric enzyme electrode, a reverse iontophoresis system and a microdialysis-based device. Improvements in glucose-sensing technology continue to be sought, e.g. wired enzyme technology, viscometric affinity sensing and totally implanted glucose sensors. Non-invasive glucose sensing is the ultimate goal of glucose monitoring, but the most investigated approach, near-infrared (NIR) spectroscopy, is presently too imprecise for clinical application. Fluorescence-based glucose sensing offers several advantages and we are investigating strategies which include NIR-based fluorescence resonance energy transfer using concanavalin A/dextran; changes in the intrinsic fluorescence of hexokinase encapsulated in sol-gel; and non-invasive glucose monitoring of cells by measuring glucose-related changes in NADP(H).


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Técnicas Biosensibles/tendencias , Automonitorización de la Glucosa Sanguínea/tendencias , Diseño de Equipo , Humanos , Microdiálisis/instrumentación , Microdiálisis/métodos , Microdiálisis/tendencias , Miniaturización , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/métodos , Monitoreo Ambulatorio/tendencias , Análisis Espectral/instrumentación , Análisis Espectral/métodos , Análisis Espectral/tendencias
14.
Expert Rev Med Devices ; 2(3): 277-86, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-16288591

RESUMEN

Assessment of the intestinal circulation in a clinical setting still presents a significant diagnostic challenge. In patients suspected of having intestinal ischemia pre- or postoperatively, there is no clinically relevant marker which can determine whether the bowel is suffering from lack of oxygen or not. Microdialysis is a microinvasive technique that makes it possible to continuously detect tissue-specific metabolic changes. Recently, it has been demonstrated that intestinal ischemia can be detected and monitored continuously by the use of a microdialysis catheter placed in the proximity of the ischemic bowel. This review summarizes the clinical dilemma of intestinal ischemia and the latest experimental results using the microdialysis technique to detect critical perfusion in the small intestine. The possibility of using microdialysis in a clinical setting is outlined with the perspective of using it as a pre- or postoperative monitoring tool in relevant patients.


Asunto(s)
Intestinos/irrigación sanguínea , Isquemia/diagnóstico , Microdiálisis/instrumentación , Microdiálisis/métodos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Humanos , Microdiálisis/tendencias , Monitoreo Fisiológico/tendencias , Evaluación de la Tecnología Biomédica , Resultado del Tratamiento
15.
Infect Dis Clin North Am ; 17(3): 599-613, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-14711079

RESUMEN

The clinical outcome of anti-infective treatment is determined by both PK and PD properties of the antibiotic. Only the free tissue concentrations of antibiotics at the target site, which are usually lower than the total plasma concentrations, are responsible for therapeutic effect. The free antibiotic concentrations at the site of action are a more appropriate PK input value for PK-PD analysis. The unbound tissue concentrations can be measured directly by microdialysis. Using plasma concentrations overestimates the target site concentrations and its clinical efficacy. The optimal dosing regimens of antibiotics have an impact on patients' outcome and cost of therapy, and reduce the emergence of resistance.


Asunto(s)
Antiinfecciosos , Microdiálisis/métodos , Animales , Antiinfecciosos/metabolismo , Antiinfecciosos/farmacocinética , Antiinfecciosos/uso terapéutico , Área Bajo la Curva , Humanos , Pruebas de Sensibilidad Microbiana , Microdiálisis/tendencias , Unión Proteica , Distribución Tisular
16.
Acta Neurochir Suppl ; 75: 3-6, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10635367

RESUMEN

The application of microdialysis for neurochemical monitoring in neurosurgery and neurointensive care is rapidly expanding in a number of clinical centers around the world. In order for microdialysis to become a future routine method in these clinical settings a number of problems, outlined in this communication, must be solved by the clinical researchers and the commercial companies. Regardless of the future success as a routine method, it is already obvious that microdialysis will be an important clinical research tool for years to come, providing new important insights into the pathophysiology of acute human brain injury.


Asunto(s)
Lesiones Encefálicas/diagnóstico , Encéfalo/metabolismo , Microdiálisis , Enfermedad Aguda , Biomarcadores , Química Encefálica , Estudios de Factibilidad , Predicción , Humanos , Microdiálisis/métodos , Microdiálisis/estadística & datos numéricos , Microdiálisis/tendencias , Monitoreo Fisiológico
17.
Artículo en Inglés | MEDLINE | ID: mdl-10097285

RESUMEN

The main goal of modern neurointensive care (NIC) of patients with acute brain injury (traumatic brain injury, neurovascular disease) is to prevent additional loss of viable brain tissue due to secondary injury processes. It is generally held that secondary injury, mediated by, for example, cerebral hypoxia/ischemia and destructive molecular cascades on the cellular level, contributes significantly to the extent of brain damage after head injury and stroke. The basic concept is that improved knowledge of the secondary injury processes will lead to new therapeutic approaches in NIC. New methods by which secondary injury processes can be detected and monitored in NIC patients are therefore greatly needed. This paper describes intracerebral microdialysis as a novel approach to neurochemical monitoring of the human brain. The main objectives are (i) to monitor cortical energy metabolism in order to detect secondary ischemia and (ii) to monitor secondary injury processes, such as glutamate receptor overactivation and increased free radical production, in NIC patients.


Asunto(s)
Lesiones Encefálicas/metabolismo , Microdiálisis , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/etiología , Cuidados Críticos , Metabolismo Energético , Radicales Libres , Humanos , Microdiálisis/tendencias , Receptores de Glutamato/fisiología
18.
Diabetes Res Clin Pract ; 97(1): 112-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22402305

RESUMEN

Continuous subcutaneous glucose monitoring has been tested in type 1 diabetes (T1D). Since in critically ill patients vascular access is granted vascular microdialysis may be preferential. To test this hypothesis comparative accuracy data for microdialysis applied for peripheral venous and subcutaneous glucose monitoring was obtained in experiments in T1D patients. Twelve T1D patients were investigated for up to 30 h. Extracorporeal vascular (MDv) and subcutaneous microdialysis (MDs) was performed. Microdialysis samples were collected in 15-60 min intervals, analyzed for glucose and calibrated to reference. MDv and MDs glucose levels were compared against reference. Median absolute relative difference was 14.0 (5.0; 28.0)% (MDv) and 9.2 (4.4; 18.4)% (MDs). Clarke Error Grid analysis showed that 100% (MDv) and 98.8% (MDv) were within zones A and B. Extracorporeal vascular and standard subcutaneous microdialysis indicated similar performance in T1D. We suggest microdialysis as a versatile technology for metabolite monitoring in subcutaneous tissue and whole blood.


Asunto(s)
Glucemia/metabolismo , Enfermedad Crítica , Diabetes Mellitus Tipo 1/sangre , Microdiálisis , Monitoreo Fisiológico/métodos , Tejido Subcutáneo/metabolismo , Adulto , Calibración , Diabetes Mellitus Tipo 1/fisiopatología , Femenino , Humanos , Masculino , Microdiálisis/métodos , Microdiálisis/tendencias , Monitoreo Fisiológico/tendencias , Valores de Referencia , Reproducibilidad de los Resultados , Tejido Subcutáneo/fisiopatología , Factores de Tiempo
19.
Anal Chim Acta ; 651(1): 1-14, 2009 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-19733728

RESUMEN

Microdialysis (MD) is a sampling technique that can be employed to monitor biological events both in vivo and in vitro. When it is coupled to an analytical system, microdialysis can provide near real-time information on the time-dependent concentration changes of analytes in the extracellular space or other aqueous environments. Online systems for the analysis of microdialysis samples enable fast, selective and sensitive analysis while preserving the temporal information. Analytical methods employed for online analysis include liquid chromatography (LC), capillary (CE) and microchip electrophoresis and flow-through biosensor devices. This review article provides an overview of microdialysis sampling and online analysis systems with emphasis on in vivo analysis. Factors that affect the frequency of analysis and, hence, the temporal resolution of these systems are also discussed.


Asunto(s)
Microdiálisis/tendencias , Animales , Técnicas Biosensibles , Cromatografía Líquida de Alta Presión , Electroforesis Capilar , Procedimientos Analíticos en Microchip , Microdiálisis/instrumentación , Microdiálisis/métodos , Sistemas en Línea/instrumentación , Ratas
20.
Pharm Res ; 24(5): 1014-25, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17458685

RESUMEN

Many decisions in drug development and medical practice are based on measuring blood concentrations of endogenous and exogenous molecules. Yet most biochemical and pharmacological events take place in the tissues. Also, most drugs with few notable exceptions exert their effects not within the bloodstream, but in defined target tissues into which drugs have to distribute from the central compartment. Assessing tissue drug chemistry has, thus, for long been viewed as a more rational way to provide clinically meaningful data rather than gaining information from blood samples. More specifically, it is often the extracellular (interstitial) tissue space that is most closely related to the site of action (biophase) of the drug. Currently microdialysis (microD) is the only tool available that explicitly provides data on the extracellular space. Although microD as a preclinical and clinical tool has been available for two decades, there is still uncertainty about the use of microD in drug research and development, both from a methodological and a regulatory point of view. In an attempt to reduce this uncertainty and to provide an overview of the principles and applications of microD in preclinical and clinical settings, an AAPS-FDA workshop took place in November 2005 in Nashville, TN, USA. Stakeholders from academia, industry and regulatory agencies presented their views on microD as a tool in drug research and development.


Asunto(s)
Microdiálisis/métodos , Modelos Biológicos , Tecnología Farmacéutica/métodos , Animales , Ensayos Clínicos como Asunto/métodos , Evaluación Preclínica de Medicamentos/métodos , Humanos , Microdiálisis/instrumentación , Microdiálisis/tendencias , Tecnología Farmacéutica/instrumentación , Tecnología Farmacéutica/tendencias , Estados Unidos , United States Food and Drug Administration
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda