Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Rheumatol Int ; 40(11): 1771-1779, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32488430

RESUMEN

Rheumatoid arthritis (RA) is a systemic autoimmune disease affecting up to 1% of the worldwide population. RA is associated with multiple extra-articular manifestations (EAMs). Middle ear, cochlea and the auditory nerve are suspected sites of RA activity and hearing loss is a possible novel EAM of RA. Objective was to investigate the association of RA with the different subtypes of hearing loss. This systematic review was performed according to the PRISMA guidelines. A random effects model meta-analysis was conducted and the I2 was used to assess heterogeneity. Twelve studies comprising 20,022 RA patients and 79,244 controls were included in this systematic review. All studies were observational and were rated to a moderate rate of bias. RA patients had nearly fourfold increased odds of sensorineural hearing loss (SNHL) compared with controls (OR 3.42; 95% CI 2.50-4.69; I2 = 13). RA patients also had a significantly increased risk of SNHL (RR 2.28; 95% CI 1.88-2.76; I2 = 0). RA patients did not have increased odds of conductive hearing loss (CHL) and mixed hearing loss (MHL) (OR 1.36; 95% CI 0.52-3.55; I2 = 22); (OR 2.73; 95% CI 0.78-9.58; I2 = 0%). RA is significantly associated with SNHL. RA is not associated with CHL and MHL. Early screening of RA patients with pure tone audiometry should be considered.


Asunto(s)
Artritis Reumatoide/epidemiología , Pérdida Auditiva Conductiva/epidemiología , Perdida Auditiva Conductiva-Sensorineural Mixta/epidemiología , Pérdida Auditiva Sensorineural/epidemiología , Audiometría de Tonos Puros , Pérdida Auditiva Conductiva/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Pérdida Auditiva Sensorineural/diagnóstico , Humanos , Tamizaje Masivo , Oportunidad Relativa
2.
Eur Arch Otorhinolaryngol ; 277(1): 55-60, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31570983

RESUMEN

PURPOSE: The primary objective of the retrospective study was to collect speech intelligibility data on children and adolescents implanted with the vibrating ossicular prosthesis (VORP) 503. METHODS: This was a retrospective, multicentre study on 55 children and adolescents from 6 German clinics aged between 5 and 17 years suffering from mixed or conductive hearing loss implanted with a VORP 503. Pre- and postoperative bone-conduction pure tone thresholds were measured at 0.5, 1, 2 and 4 kHz, and word recognition scores in the unaided and VORP 503-aided conditions using monosyllabic speech intelligibility tests measured at 65-dB sound pressure level (SPL) were determined. RESULTS: Mean pre- and postoperative bone-conduction thresholds remained unchanged, showing the preservation of inner ear hearing. Speech intelligibility assessed in quiet at 65-dB SPL improved on average from 24.5% (SD ± 25.4) unaided to 86.4% (SD ± 13.4) aided. The average improvement of 61.9% (SD ± 25.3) was clinically and statistically significant. A total of three complications were found in the medical records of 55 subjects. The responsible investigators judged these events as procedure related. CONCLUSION: The treatment of children suffering from conductive or mixed hearing loss with the VORP 503 implant demonstrates excellent aided benefit in terms of speech understanding and only minor complications.


Asunto(s)
Pérdida Auditiva Conductiva/cirugía , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Prótesis Osicular , Adolescente , Umbral Auditivo , Conducción Ósea/fisiología , Niño , Preescolar , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pruebas Auditivas , Humanos , Estudios Longitudinales , Masculino , Estudios Retrospectivos , Inteligibilidad del Habla , Resultado del Tratamiento , Vibración
3.
Eur Arch Otorhinolaryngol ; 277(3): 715-725, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31811384

RESUMEN

INTRODUCTION: The BAHA (bone-anchored hearing aid) Attract is a magnetic transcutaneous bone conduction device anchored into the temporal bone. The standard surgical technique for BAHA Attract is a multi-tools time-consuming process, which requires a large cutaneous incision. The objective of this study is to describe and test the feasibility of a minimally invasive pocket (MIP) technique for Magnet Bone Implant Hearing Aid (MBIHA) with a modified magnet of BAHA Attract without fixation and without any tissue reduction. We use a 3-cm vertical skin incision and a subperiosteal pocket. METHOD: A study of 10 patients with conductive or mixed hearing loss who benefited from a MBIHA using the MIP technique is presented. The pure tone average (PTA) (dB) for air-conduction thresholds and the speech recognition threshold (SRT) (dB) in speech audiometry in quiet are calculated. The Entific Medical Systems (EMS) questionnaire and the postoperative clinical outcomes are realized. RESULTS: We found a significant improvement of 33.8 dB on average for the PTA and 44.8 dB for the SRT with MBIHA at 3 months, compared with unaided situation. No implant was removed or displaced after 2 years of follow-up. The skin condition remains intact in all the cases. CONCLUSION: The minimally subperiosteal pocket surgical technique MIP without fixation and with tissue preservation for the MBIHA is safe, rapid and effective for patients with conductive or mixed hearing loss. It opens new perspectives of development and modify conventional concept in magnetic coupling of bone-conducted device.


Asunto(s)
Prótesis Anclada al Hueso , Audífonos , Pérdida Auditiva Conductiva/cirugía , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Implantación de Prótesis/métodos , Adolescente , Adulto , Percepción Auditiva , Niño , Estudios de Factibilidad , Femenino , Pérdida Auditiva Bilateral/diagnóstico , Pérdida Auditiva Bilateral/fisiopatología , Pérdida Auditiva Bilateral/cirugía , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pérdida Auditiva Unilateral/diagnóstico , Pérdida Auditiva Unilateral/fisiopatología , Pérdida Auditiva Unilateral/cirugía , Humanos , Imanes , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Implantación de Prótesis/instrumentación , Colgajos Quirúrgicos , Resultado del Tratamiento , Adulto Joven
4.
HNO ; 68(Suppl 2): 106-115, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32725263

RESUMEN

Here, we describe the surgical technique for implanting a new, active, transcutaneous bone conduction hearing aid. The implant technology is based on a system that has been in use reliably since 2012. The geometry of the new implant has been adapted based on experience with previously introduced implants. The surgery was feasible, standardized, and safe. Due to the optimized geometric design that improved the bone fit, it is not necessary to use specialized, detailed preoperative planning, except in challenging anatomical conditions; e.g., in young children, malformations, poor pneumatization, or after a canal wall down mastoidectomy.


Asunto(s)
Conducción Ósea , Audífonos , Perdida Auditiva Conductiva-Sensorineural Mixta , Niño , Preescolar , Pérdida Auditiva Conductiva , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Humanos , Prótesis e Implantes , Resultado del Tratamiento
5.
Audiol Neurootol ; 23(6): 316-325, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30650421

RESUMEN

OBJECTIVE: To evaluate the long-term safety and performance of four different vibroplasty couplers (round window, oval window, CliP and Bell coupler) in combination with an active middle ear implant. METHODS: This was a multicentre, prospective, long-term study including 5 German hospitals. Thirty adult subjects suffering from conductive or mixed hearing loss were initially enrolled for the study, 24 of these were included in the final analysis with up to 36 months of postsurgical follow-up data. Bone conduction and air conduction were measured pre- and postoperatively to evalu ate safety. Postoperative aided sound field thresholds and Freiburger monosyllable word recognition scores were compared to unaided pre-implantation results to confirm performance. Additional speech tests compared postoperative unaided with aided results. To determine patient satisfaction, an established quality-of-life questionnaire developed for conventional hearing aid usage was administered to all subjects. RESULTS: Mean postoperative bone conduction thresholds remained stable throughout the whole study period. Mean functional gain for all couplers investigated was 38.5 ± 11.4 dB HL (12 months) and 38.8 ± 12.5 dB HL (36 months). Mean word recognition scores at 65 dB SPL increased from 2.9% in the unaided by 64.2% to 67.1% in the aided situation. The mean postoperative speech reception in quiet (or 50% understanding of words in sentences) shows a speech intelligibility improvement at 36 months of 17.8 ± 12.4 dB SPL over the unaided condition. The signal-to-noise ratio (SNR) improved by 5.9 ± 7.2 dB SNR over the unaided condition. High subjective device satisfaction was reflected by the International Inventory for Hearing Aids scored very positively. CONCLUSION: A significant improvement was seen with all couplers, and audiological performance did not significantly differ between 12 and 36 months after surgery.


Asunto(s)
Pérdida Auditiva Conductiva/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Prótesis Osicular , Diseño de Prótesis , Adulto , Anciano , Audiometría de Tonos Puros , Umbral Auditivo , Femenino , Estudios de Seguimiento , Alemania , Pérdida Auditiva Conductiva/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Reemplazo Osicular/rehabilitación , Satisfacción del Paciente , Estudios Prospectivos
6.
Acta Derm Venereol ; 98(7): 655-659, 2018 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-29648672

RESUMEN

Psoriasis is a systemic inflammatory disorder associated with many other chronic and progressive diseases. There are few studies on the association of psoriasis with alterations in auditory function. A clinical and instrumental pilot study of auditory function was performed with 77 psoriatic patients and 77 age- and sex-matched healthy controls. The main results were: (i) hearing loss, mostly of sensorineural type, was significantly more frequent in patients than in controls; (ii) conductive and mixed hearing loss were more frequent in arthropathic than in non-arthropathic psoriatic patients; (iii) duration of psoriasis > 10 years or smoking were associated with higher frequency of hearing loss; (iv) psoriasis was more severe in patients with hearing loss than in those without hearing loss. Tympanogram abnormalities were found in patients more often than in controls. These data expand the list of extracutaneous conditions associated with psoriasis, and support the need for further basic and clinical research in this field.


Asunto(s)
Vías Auditivas/fisiopatología , Pérdida Auditiva Conductiva/etiología , Perdida Auditiva Conductiva-Sensorineural Mixta/etiología , Pérdida Auditiva Sensorineural/etiología , Audición , Psoriasis/complicaciones , Adulto , Anciano , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Pruebas Auditivas , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Proyectos Piloto , Psoriasis/diagnóstico , Factores de Riesgo , Adulto Joven
7.
Vestn Otorinolaringol ; 83(3): 65-68, 2018.
Artículo en Ruso | MEDLINE | ID: mdl-29953059

RESUMEN

This article was designed to report a clinical case of an acute acoustic injury inflicted by a discharge of the lightning ball during the early postoperative period in a female patient following surgical stapedoplasty. The acoustic impact resulted in a marked deterioration of hearing in the operated ear with simultaneous elevation of the threshold of bone sound conduction to above the preoperative value. It is concluded that the patients who had undergone the stapedoplastic surgical intervention should be advised to avoid strong acoustic impacts during the postoperative period.


Asunto(s)
Perdida Auditiva Conductiva-Sensorineural Mixta , Pérdida Auditiva Provocada por Ruido/complicaciones , Otosclerosis , Complicaciones Posoperatorias , Cirugía del Estribo , Adulto , Audiometría/métodos , Tratamiento Conservador/métodos , Femenino , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Humanos , Otosclerosis/diagnóstico , Otosclerosis/fisiopatología , Otosclerosis/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Periodo Posoperatorio , Cirugía del Estribo/efectos adversos , Cirugía del Estribo/métodos , Resultado del Tratamiento
8.
Eur Arch Otorhinolaryngol ; 274(8): 3011-3019, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28534117

RESUMEN

Examination of objective as well as subjective outcomes with a new transcutaneous bone-anchored hearing aid device. The study was designed as a prospective multicenter consecutive case-series study involving tertiary referral centers at two Danish University Hospitals. A total of 23 patients were implanted. Three were lost to follow-up. Patients had single-sided deafness, conductive or mixed hearing loss. INTERVENTION: Rehabilitative. Aided and unaided sound field hearing was evaluated objectively using (1) pure warble tone thresholds, (2) pure-tone average (PTA4), (3) speech discrimination score (SDS) in quiet, and (4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective benefit was evaluated by three validated questionnaires: (1) the IOI-HA, (2) the SSQ-12, and (3) a questionnaire evaluating both the frequency and the duration of hearing aid usage. The mean aided PTA4 was lowered by 14.7 dB. SDS was increased by 37.5% at 50 dB SPL, SRT50% in noise improved 1.4 dB. Aided thresholds improved insignificantly at frequencies above 2 kHz. 52.9% of the patients used their device every day, and 76.5% used the device at least 5 days a week. Mean IOI-HA score was 3.4, corresponding to a good benefit. In SSQ-12, "quality of hearing" scored especially high. Patients with a conductive and/or mixed hearing loss benefitted the most. This device demonstrates a significant subjective hearing benefit 8 month post surgery. In patients with conductive and/or mixed hearing losses, patient satisfaction and frequency of use were high. Objective gain measures showed less promising results especially in patients with single-sided deafness (SSD) compared to other bone conduction devices.


Asunto(s)
Audífonos , Pérdida Auditiva Conductiva , Perdida Auditiva Conductiva-Sensorineural Mixta , Satisfacción del Paciente/estadística & datos numéricos , Adulto , Anciano , Dinamarca , Femenino , Audífonos/psicología , Audífonos/estadística & datos numéricos , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/psicología , Pérdida Auditiva Conductiva/terapia , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/psicología , Perdida Auditiva Conductiva-Sensorineural Mixta/terapia , Pruebas Auditivas/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Encuestas y Cuestionarios
9.
Ear Hear ; 37(2): 177-88, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26627469

RESUMEN

OBJECTIVES: Five databases were mined to examine distributions of air-bone gaps obtained by automated and manual audiometry. Differences in distribution characteristics were examined for evidence of influences unrelated to the audibility of test signals. DESIGN: The databases provided air- and bone-conduction thresholds that permitted examination of air-bone gap distributions that were free of ceiling and floor effects. Cases with conductive hearing loss were eliminated based on air-bone gaps, tympanometry, and otoscopy, when available. The analysis is based on 2,378,921 threshold determinations from 721,831 subjects from five databases. RESULTS: Automated audiometry produced air-bone gaps that were normally distributed suggesting that air- and bone-conduction thresholds are normally distributed. Manual audiometry produced air-bone gaps that were not normally distributed and show evidence of biasing effects of assumptions of expected results. In one database, the form of the distributions showed evidence of inclusion of conductive hearing losses. CONCLUSIONS: Thresholds obtained by manual audiometry show tester bias effects from assumptions of the patient's hearing loss characteristics. Tester bias artificially reduces the variance of bone-conduction thresholds and the resulting air-bone gaps. Because the automated method is free of bias from assumptions of expected results, these distributions are hypothesized to reflect the true variability of air- and bone-conduction thresholds and the resulting air-bone gaps.


Asunto(s)
Audiometría de Tonos Puros/métodos , Conducción Ósea , Pérdida Auditiva Conductiva/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Pérdida Auditiva Sensorineural/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
10.
B-ENT ; 12(1): 41-51, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27097393

RESUMEN

OBJECTIVES: Variability in Baha® sound processor fittings arise from several sources including the nature of the implant-to-bone transmission and transcranial attenuation in patients with single-sided sensorineural deafness. One method of improving the predictability of Baha fittings is to measure the individual patient's actual bone conduction thresholds via the implant, thereby removing the influence of skin thickness and/or implant location site. METHODOLOGY: One hundred thirty eight adult wearers of the Baha System participated in the study. Direct bone conduction thresholds were obtained through the BC Direct feature of the Cochlear™ Baha Fitting Software combined with the CochlearBaha BP100 sound processor. Test-retest reliability measurement was performed in 58 participants. RESULTS: Improved transmission of sound through the implant rather than transcutaneously through the skin was confirmed. On average, the BC Direct thresholds were closer to the patient's unmasked thresholds than the masked values. In patients with single-sided sensorineural deafness, BC Direct results were elevated compared to the contralateral bone conduction thresholds due to transcranial attenuation. The test-retest reliability for the BC Direct measurements was within ±5 dB, which is in within the accepted variability for audiometric test measurements. CONCLUSIONS: Direct bone conduction measurement provides a validated method of comparing the transcutaneous thresholds as measured through audiometry with the percutaneous responses from the Baha sound processor. The Baha fitting based on direct measurements of bone conduction may require less fine-tuning and provide a greater understanding of the variability of the bone conduction sound pathway.


Asunto(s)
Pérdida Auditiva Conductiva/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Unilateral/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Audiometría , Umbral Auditivo , Conducción Ósea , Femenino , Audífonos , Pérdida Auditiva Conductiva/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Pérdida Auditiva Sensorineural/rehabilitación , Pérdida Auditiva Unilateral/rehabilitación , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
11.
Eur Arch Otorhinolaryngol ; 272(9): 2261-6, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25012703

RESUMEN

Cochlear implantation is associated with deterioration in hearing. Despite the fact that the damage is presumed to be of sensory origin, residual hearing is usually assessed by air-conduction thresholds alone. This study sought to determine if surgery may cause changes in air- and bone-conduction thresholds producing a mixed-type hearing loss. The sample included 18 patients (mean age 37 years) with an air-bone gap of 10 dB over three consecutive frequencies and measurable masked and reliable bone-conduction thresholds of operated and non-operated ears who underwent cochlear implant surgery. All underwent comprehensive audiologic and otologic assessment and imaging before and after surgery. The air-bone gap in the treated ears was 17-41 dB preoperatively and 13-59 dB postoperatively over 250-4,000 Hz. Air-conduction thresholds in the treated ears significantly deteriorated after surgery, by a mean of 10-21 dB. Bone-conduction levels deteriorated nonsignificantly by 0.8-7.5 dB. The findings indicate that the increase in air-conduction threshold after cochlear implantation accounts for most of the postoperative increase in the air-bone gap. Changes in the mechanics of the inner ear may play an important role. Further studies in larger samples including objective measures of inner ear mechanics may add information on the source of the air-bone gap.


Asunto(s)
Implantación Coclear/efectos adversos , Perdida Auditiva Conductiva-Sensorineural Mixta/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Conducción Ósea , Niño , Preescolar , Implantes Cocleares , Femenino , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
12.
Eur Arch Otorhinolaryngol ; 272(12): 3705-8, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25534285

RESUMEN

Turner syndrome (TS) is one of the most frequently encountered sex-linked chromosomal abnormalities, occurring in one per 2,000 female births. These patients present with short stature and failure to begin puberty. In this syndrome, there are multiple organ abnormalities, including auditory disorders. TS patients were referred to the ENT clinic by a pediatric endocrinologist. A questionnaire was filled out and the patients went through a complete otologic examination. They were then referred to the audiology clinic to undergo audiologic test battery plus high-frequency pure tone audiometry. From a total of 48 ears examined, 11 (22.9 %) had a normal audiometry. Mid-frequency sensorineural hearing loss (SNHL), high-frequency SNHL, combined and mixed hearing loss were diagnosed in 6 (12/5 %), 20 (41/7 %), 6 (12/5 %) and 1 (2/1 %) ear, respectively. Tympanogram results showed normal compliance (A, As, Ad) in the majority of cases. B and C patterns were found in a few cases. Speech discrimination score was normal in all patients whereas speech reception threshold was normal in 92 % of the ears. Audiometry abnormality especially SNHL is common in TS patients, with the high-frequency pattern being the most frequent.


Asunto(s)
Pérdida Auditiva de Alta Frecuencia/etiología , Perdida Auditiva Conductiva-Sensorineural Mixta/etiología , Pérdida Auditiva Sensorineural/etiología , Síndrome de Turner/complicaciones , Adolescente , Adulto , Audiometría de Tonos Puros , Niño , Preescolar , Femenino , Pérdida Auditiva de Alta Frecuencia/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Pérdida Auditiva Sensorineural/diagnóstico , Humanos , Irán , Adulto Joven
13.
Int J Audiol ; 55(7): 419-24, 2015 07.
Artículo en Inglés | MEDLINE | ID: mdl-27176657

RESUMEN

OBJECTIVE: The efficacy of wireless connectivity in bone-anchored hearing was studied by comparing the wireless and acoustic performance of the Ponto Plus sound processor from Oticon Medical relative to the acoustic performance of its predecessor, the Ponto Pro. STUDY SAMPLE: Nineteen subjects with more than two years' experience with a bone-anchored hearing device were included. Thirteen subjects were fitted unilaterally and six bilaterally. DESIGN: Subjects served as their own control. First, subjects were tested with the Ponto Pro processor. After a four-week acclimatization period performance the Ponto Plus processor was measured. In the laboratory wireless and acoustic input levels were made equal. In daily life equal settings of wireless and acoustic input were used when watching TV, however when using the telephone the acoustic input was reduced by 9 dB relative to the wireless input. RESULTS: Speech scores for microphone with Ponto Pro and for both input modes of the Ponto Plus processor were essentially equal when equal input levels of wireless and microphone inputs were used. Only the TV-condition showed a statistically significant (p <5%) lower speech reception threshold for wireless relative to microphone input. In real life, evaluation of speech quality, speech intelligibility in quiet and noise, and annoyance by ambient noise, when using landline phone, mobile telephone, and watching TV showed a clear preference (p <1%) for the Ponto Plus system with streamer over the microphone input. Due to the small number of respondents with landline phone (N = 7) the result for noise annoyance was only significant at the 5% level. CONCLUSION: Equal input levels for acoustic and wireless inputs results in equal speech scores, showing a (near) equivalence for acoustic and wireless sound transmission with Ponto Pro and Ponto Plus. The default 9-dB difference between microphone and wireless input when using the telephone results in a substantial wireless benefit when using the telephone. The preference of wirelessly transmitted audio when watching TV can be attributed to the relatively poor sound quality of backward facing loudspeakers in flat screen TVs. The ratio of wireless and acoustic input can be easily set to the user's preference with the streamer's volume control.


Asunto(s)
Acústica/instrumentación , Conducción Ósea , Audífonos , Pérdida Auditiva Bilateral/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Percepción del Habla , Tecnología Inalámbrica/instrumentación , Estimulación Acústica , Adulto , Anciano , Audiometría de Tonos Puros , Umbral Auditivo , Diseño de Equipo , Femenino , Pérdida Auditiva Bilateral/diagnóstico , Pérdida Auditiva Bilateral/fisiopatología , Pérdida Auditiva Bilateral/psicología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/psicología , Humanos , Masculino , Persona de Mediana Edad , Ruido/efectos adversos , Prioridad del Paciente , Enmascaramiento Perceptual , Personas con Deficiencia Auditiva/psicología , Inteligibilidad del Habla , Prueba del Umbral de Recepción del Habla
14.
Artículo en Inglés | MEDLINE | ID: mdl-25661010

RESUMEN

OBJECTIVE: To describe our experience with positioning the Bonebridge (BB) device, a semi-implantable transcutaneous bone conduction implant for patients with conductive and mixed hearing loss as well as for those suffering from single-sided deafness. METHODS: The following is a retrospective case review of 4 adults suffering from conductive or mixed hearing loss and single-sided deafness. The BB device was implanted unilaterally via 2 different approaches selected case by case: the presigmoid transmastoid and the retrosigmoid approach. An audiological evaluation in the free field was conducted to observe the functional benefit with this device. The Glasgow Health Status Inventory (GHSI) and the Glasgow Benefit Inventory (GBI) questionnaires were filled out to evaluate patients' quality of life in relationship to the intervention. RESULTS: No intra- or postoperative complications were observed. The performance in the speech test in all 4 cases reached 100% in the aided condition at 65 dB, while in the unaided condition at 65 dB, it was less than 10%. The GHSI and GBI questionnaires showed an improvement in quality of life after implantation. CONCLUSIONS: The BB device is a safe and effective solution for individuals with pathologies such as chronic otitis media, atresia auris and otosclerosis with inadequate benefit from conventional surgery or bone conduction hearing aids.


Asunto(s)
Audífonos , Pérdida Auditiva Conductiva/terapia , Perdida Auditiva Conductiva-Sensorineural Mixta/terapia , Adulto , Anciano , Audiometría , Conducción Ósea , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/etiología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/etiología , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Percepción del Habla , Resultado del Tratamiento
15.
Ear Hear ; 35(1): e1-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24080948

RESUMEN

OBJECTIVES: The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. DESIGN: Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. RESULTS: Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and specificity of the test battery vary depending on the size of this deviation, but increase with increasing ABG size, with decreasing test frequency, and when results from multiple test frequencies are taken into account. The individual automatic tests comprising the battery were found to be reliable and valid, with strong, significant correlations between the test and retest results (r = 0.81 to 0.99; p < 0.0001) and between automatic and manual audiometry procedures (r = 0.98 to 0.99; p < 0.0001). CONCLUSIONS: The presence of an ABG can be predicted with a reasonably high degree of accuracy using AC tests alone. Applications of such a test battery include any clinical context in which bone conduction audiometry or specialized diagnostic equipment is unavailable or impractical. Examples of these include self-fitting hearing aids, whose efficacy relies on the ability of the device to automatically administer an in situ hearing test; self-administered adult hearing screenings in both clinical and home environments; large-scale industrial hearing conservation programs; and test environments in which ambient noise levels exceed the maximum permissible levels for unoccluded ears.


Asunto(s)
Audiometría de Tonos Puros/métodos , Pérdida Auditiva Conductiva/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Umbral Auditivo , Estudios de Casos y Controles , Diagnóstico por Computador/métodos , Femenino , Pruebas Auditivas/métodos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Adulto Joven
16.
Eur Arch Otorhinolaryngol ; 271(5): 1339-43, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24504491

RESUMEN

Hearing is of utmost importance for normal speech and social development. Even children who have mild or unilateral permanent hearing loss may experience difficulties with understanding speech, as well as problems with educational and psycho-social development. The increasing advantages of middle-ear implant technologies are opening new perspectives for restoring hearing. Active middle-ear implants can be used in children and adolescents with hearing loss. In addition to the well-documented results for improving speech intelligibility and quality of hearing in sensorineural hearing loss active middle-ear implants are now successfully used in patients with conductive and mixed hearing loss. In this article we present a case of successful, single-stage vibroplasty, on the right side with the fixation of the FMT on the stapes and PORP CLiP vibroplasty on the left side in a 6-year-old girl with bilateral mixed hearing loss and multiple dyslalia associated with Franceschetti syndrome (mandibulofacial dysostosis). CT revealed bilateral middle-ear malformations as well as an atretic right and stenotic left external auditory canal. Due to craniofacial dysmorphia airway and (post)operative, management is significantly more difficult in patients with a Franceschetti syndrome which in this case favoured a single-stage bilateral procedure. No intra- or postoperative surgical complications were reported. The middle-ear implants were activated 4 weeks after surgery. In the audiological examination 6 months after surgery, the child showed 100% speech intelligibility with activated implants on each side.


Asunto(s)
Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Disostosis Mandibulofacial/rehabilitación , Prótesis Osicular , Audiometría del Habla , Umbral Auditivo/fisiología , Niño , Femenino , Estudios de Seguimiento , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Humanos , Trastornos del Desarrollo del Lenguaje/diagnóstico , Trastornos del Desarrollo del Lenguaje/rehabilitación , Disostosis Mandibulofacial/diagnóstico , Diseño de Prótesis , Prueba del Umbral de Recepción del Habla , Tomografía Computarizada por Rayos X , Vibración
17.
Eur Arch Otorhinolaryngol ; 271(9): 2421-5, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24096812

RESUMEN

The objective of the study was to investigate the relationship between extent of otosclerotic foci and audiological findings in otosclerotic patients with mixed hearing loss using high-resolution computed tomography (HRCT) and also to measure the density of bony labyrinth in otosclerotic patients and compared with control group. This was a retrospective study. Twenty-five patients with clinical otosclerosis and mixed hearing loss were included in the study. The average threshold of air-bone conductions (AC, BC) within the 0.5-4 kHz frequency range, and average air bone gap (ABG) were calculated. Eleven patients with normal HRCT who received cochlear implant were included in the study as the control group. The lesions in HRCT were staged according to their extension. Eight different points of the otic capsule in each patient were measured using HRCT. Fifty ears total, from 25 patients, had bilateral otosclerosis. The mean AC of all the ears was 63 dB, mean BC was 35.2 dB, and mean ABG was 27.8 dB. HRCT staging indicated 22 ears had Grade 1, 21 ears had Grade 2, and 7 ears had Grade 3 lesions. There was a statistically significant difference between the mean AC, BC of ears with Grade 1 and Grade 2 when compared with the mean AC, BC of ears with Grade 3. When comparing the densitometric measurements of fissula ante fenestram localizations, a statistically significant difference was observed. HRCT examination and densitometric measurements in otosclerotic patients with mixed hearing loss presented significant results. We were unable to show a significant relationship between early stage and hearing thresholds, but there was a significant relationship in advanced stage. Densitometric measurements may provide significant results for otosclerosis, particularly for the FAF region when comparing with control group.


Asunto(s)
Cóclea , Perdida Auditiva Conductiva-Sensorineural Mixta , Otosclerosis , Adulto , Anciano , Anciano de 80 o más Años , Conducción Ósea , Cóclea/diagnóstico por imagen , Cóclea/patología , Investigación sobre la Eficacia Comparativa , Densitometría/métodos , Femenino , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/etiología , Humanos , Masculino , Persona de Mediana Edad , Otosclerosis/complicaciones , Otosclerosis/diagnóstico , Gravedad del Paciente , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
18.
Eur Arch Otorhinolaryngol ; 271(5): 1007-14, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23632874

RESUMEN

The aim of this study was to analyze the impact of clinical factors on the outcomes of otosclerosis surgery and support patients' access to evidence-based information in pre-operative counseling to optimize their choices. A total of 109 ears in 93 patients undergoing stapes surgery in a tertiary referral center were included. Variables with a potential impact on hearing outcomes were recorded, with an emphasis on factors that were readily available pre-operatively. Hearing success was defined as a post-operative air-bone gap ≤10 dB. Logistic regression analysis was used to determine the factors independently contributing to the prediction of hearing success. The mean follow-up period was 18.0 months. Univariate and multivariate analyses indicated that none of the pre-operative factors (piston type, age, sex, affected side, tinnitus, vertigo, and pre-operative hearing thresholds) affected hearing success significantly (all p > 0.05). In conclusion, self-crimping Nitinol piston provides comparable hearing outcomes with conventional manual-crimping prostheses. However, Nitinol piston offers a technical simplification of a surgical procedure and an easier surgical choice for patients. In addition, age is not a detriment to hearing gain and instead might result in better use of hearing aids in older adults, thus facilitating social hearing recovery. Finally, hearing success does not depend on the extent of pre-operative hearing loss. Hence, patients with poor cochlear function should not be considered poor candidates for surgery. The predictive model has established recommendations for otologists for better case selection, and factors that are readily available pre-operatively may inform patients more explicitly about expected post-operative audiometric results.


Asunto(s)
Prótesis Osicular , Otosclerosis/cirugía , Planificación de Atención al Paciente , Selección de Paciente , Cirugía del Estribo/métodos , Adulto , Umbral Auditivo/fisiología , Conducción Ósea/fisiología , Medicina Basada en la Evidencia , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/cirugía , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Humanos , Masculino , Análisis Multivariante , Otosclerosis/diagnóstico , Otosclerosis/fisiopatología , Educación del Paciente como Asunto , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Pronóstico , Diseño de Prótesis , Estudios Retrospectivos
19.
Trends Hear ; 28: 23312165241264466, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39106413

RESUMEN

This study investigated sound localization abilities in patients with bilateral conductive and/or mixed hearing loss (BCHL) when listening with either one or two middle ear implants (MEIs). Sound localization was measured by asking patients to point as quickly and accurately as possible with a head-mounted LED in the perceived sound direction. Loudspeakers, positioned around the listener within a range of +73°/-73° in the horizontal plane, were not visible to the patients. Broadband (500 Hz-20 kHz) noise bursts (150 ms), roved over a 20-dB range in 10 dB steps was presented. MEIs stimulate the ipsilateral cochlea only and therefore the localization response was not affected by crosstalk. Sound localization was better with bilateral MEIs compared with the unilateral left and unilateral right conditions. Good sound localization performance was found in the bilaterally aided hearing condition in four patients. In two patients, localization abilities equaled normal hearing performance. Interestingly, in the unaided condition, when both devices were turned off, subjects could still localize the stimuli presented at the highest sound level. Comparison with data of patients implanted bilaterally with bone-conduction devices, demonstrated that localization abilities with MEIs were superior. The measurements demonstrate that patients with BCHL, using remnant binaural cues in the unaided condition, are able to process binaural cues when listening with bilateral MEIs. We conclude that implantation with two MEIs, each stimulating only the ipsilateral cochlea, without crosstalk to the contralateral cochlea, can result in good sound localization abilities, and that this topic needs further investigation.


Asunto(s)
Estimulación Acústica , Pérdida Auditiva Conductiva , Perdida Auditiva Conductiva-Sensorineural Mixta , Prótesis Osicular , Localización de Sonidos , Humanos , Localización de Sonidos/fisiología , Femenino , Masculino , Persona de Mediana Edad , Pérdida Auditiva Conductiva/fisiopatología , Pérdida Auditiva Conductiva/cirugía , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/rehabilitación , Adulto , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Anciano , Pérdida Auditiva Bilateral/fisiopatología , Pérdida Auditiva Bilateral/rehabilitación , Pérdida Auditiva Bilateral/diagnóstico , Pérdida Auditiva Bilateral/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Señales (Psicología) , Adulto Joven , Umbral Auditivo , Conducción Ósea/fisiología
20.
Int J Audiol ; 52(4): 209-18, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23527900

RESUMEN

OBJECTIVE: This study was undertaken to determine the efficacy of the round window (RW) application of the vibrant soundbridge (VSB) in patients with mixed or conductive hearing loss. DESIGN: Speech in quiet and in noise were compared to preoperative data attained with conventional hearing aids so that each subject served as his or her own control in a single test protocol. STUDY SAMPLE: Eighteen adults implanted monaurally with the VSB in the poorer hearing ear. Experience with the VSB ranged from nine to 25 months. RESULTS: Sixteen of the 18 subjects were successful VSB users, wearing their device all waking hours. There was no significant deterioration in the averaged bone conduction results preoperatively versus post-operatively (p>0.05). Speech recognition in quiet results were not significantly different to performance attained whilst wearing hearing aids (p>0.05). Speech recognition in noise performance was substantially improved with use of the VSB in most test conditions. CONCLUSIONS: For the majority of the subjects, the VSB was an effective method of hearing restoration for their mixed and conductive hearing loss.


Asunto(s)
Corrección de Deficiencia Auditiva/instrumentación , Audífonos , Pérdida Auditiva Conductiva/rehabilitación , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Implantación de Prótesis/instrumentación , Ventana Redonda/fisiopatología , Adulto , Anciano , Audiometría de Tonos Puros , Audiometría del Habla , Conducción Ósea , Diseño de Equipo , Femenino , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Pérdida Auditiva Conductiva/psicología , Perdida Auditiva Conductiva-Sensorineural Mixta/diagnóstico , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Perdida Auditiva Conductiva-Sensorineural Mixta/psicología , Humanos , Masculino , Persona de Mediana Edad , Ruido/efectos adversos , Enmascaramiento Perceptual , Personas con Deficiencia Auditiva/psicología , Diseño de Prótesis , Reconocimiento en Psicología , Inteligibilidad del Habla , Percepción del Habla , Terapéutica , Factores de Tiempo , Vibración , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda