Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
2.
J Agric Food Chem ; 54(20): 7929-34, 2006 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-17002472

RESUMEN

Sodium iron ethylenediaminetetraacetate (NaFeEDTA) has superior iron bioavailability especially in foods containing iron absorption inhibitors. However, mechanisms involved in the absorption and subsequent partitioning of iron complexed with EDTA are poorly understood. Our objectives were to compare retention and tissue distribution of iron administered to rats either as FeSO4 or NaFeEDTA, either orally (OR) or subcutaneously (SC). Weanling rats were fed semipurified diets supplemented with either FeSO4 or NaFeEDTA for 7 days. They were then given a meal containing 59Fe-labeled FeSO4 or NaFeEDTA, or they were injected SC with these two forms of radiolabeled Fe. 59Fe retention was measured by whole body counting. Urine was collected and counted at 24 h intervals throughout the counting period. Tissue samples were analyzed for nonheme iron and 59Fe activity. Absorption of iron from FeSO4 or NaFeEDTA was similar (57.7 and 53.4%, respectively). Seventy-seven percent of the injected Na59FeEDTA was excreted in the urine within 24 h, whereas only 0.5, 0.8, and 1.4% of the injected 59FeSO4, oral 59FeSO4, and oral Na59FeEDTA, respectively, was excreted in the urine. The nonheme iron content was lower in the liver and spleen, by 56.8 and 28.4%, respectively, among rats consuming the NaFeEDTA diet as compared to rats fed FeSO4. We conclude that iron is dissociated from EDTA prior to or during intestinal absorption and that some fraction of the dissociated EDTA is absorbed separately from the iron.


Asunto(s)
Compuestos Férricos/farmacocinética , Absorción Intestinal , Hierro/farmacocinética , Animales , Disponibilidad Biológica , Ácido Edético/metabolismo , Ácido Edético/farmacocinética , Compuestos Férricos/metabolismo , Hierro/análisis , Hierro/metabolismo , Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/orina , Masculino , Ratas , Ratas Sprague-Dawley
3.
Appl Radiat Isot ; 64(10-11): 1412-6, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16580219

RESUMEN

The half-life of 55Fe was determined experimentally and compared with literature values. A solid 55Fe source was prepared by electrodeposition and repeatedly measured in an X-ray detector at a constant, low solid angle. In total, more than six hundred measurements were performed over a period of ten months, corresponding to one third of the half-life. The experimental method and the corresponding uncertainty budget are presented. The result of 1005.2+/-1.4 days is slightly higher than the current recommended values.


Asunto(s)
Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/química , Modelos Químicos , Radiometría/métodos , Algoritmos , Simulación por Computador , Guías como Asunto , Semivida , Radioisótopos de Hierro/normas , Dosis de Radiación , Radiometría/instrumentación , Estándares de Referencia , Valores de Referencia
4.
Appl Radiat Isot ; 64(10-11): 1446-53, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16563780

RESUMEN

In this paper, we apply the CIEMAT/NIST method to the three low-Z electron-capture nuclides 54Mn, 55Fe and 65Zn by using the KLM and KL1L2L3M atomic rearrangement models, respectively. The counting efficiencies are computed with the new code EMILIA, which comprises an improved model for the interaction of low-energy X-rays with the scintillation cocktail. The calculated counting efficiencies are compared with experimental results.


Asunto(s)
Algoritmos , Electrones , Modelos Químicos , Radioisótopos/análisis , Conteo por Cintilación/métodos , Programas Informáticos , Simulación por Computador , Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/química , Manganeso/análisis , Manganeso/química , Dosis de Radiación , Radioisótopos/química , Radioisótopos de Zinc/análisis , Radioisótopos de Zinc/química
5.
Environ Pollut ; 216: 636-645, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27357483

RESUMEN

The use of zero-valent iron nanoparticles (nZVI) has been advocated for the remediation of both soils and groundwater. A key parameter affecting nZVI remediation efficacy is the mobility of the particles as this influences the reaction zone where remediation can occur. However, by engineering nZVI particles with increased stability and mobility we may also inadvertently facilitate nZVI-mediated contaminant transport away from the zone of treatment. Previous nZVI mobility studies have often been limited to model systems as the presence of background Fe makes detection and tracking of nZVI in real systems difficult. We overcame this problem by synthesising Fe-59 radiolabelled nZVI. This enabled us to detect and quantify the leaching of nZVI-derived Fe-59 in intact soil cores, including a soil contaminated by Chromated-Copper-Arsenate. Mobility of a commercially available nZVI was also tested. The results showed limited mobility of both nanomaterials; <1% of the injected mass was eluted from the columns and most of the radiolabelled nZVI remained in the surface soil layers (the primary treatment zone in this contaminated soil). Nevertheless, the observed breakthrough of contaminants and nZVI occurred simultaneously, indicating that although the quantity transported was low in this case, nZVI does have the potential to co-transport contaminants. These results show that direct injection of nZVI into the surface layers of contaminated soils may be a viable remediation option for soils such as this one, in which the mobility of nZVI below the injection/remediation zone was very limited. This Fe-59 experimental approach can be further extended to test nZVI transport in a wider range of contaminated soil types and textures and using different application methods and rates. The resulting database could then be used to develop and validate modelling of nZVI-facilitated contaminant transport on an individual soil basis suitable for site specific risk assessment prior to nZVI remediation.


Asunto(s)
Arseniatos/química , Hierro/química , Nanopartículas del Metal/química , Contaminantes del Suelo/química , Restauración y Remediación Ambiental , Radioisótopos de Hierro/análisis , Polímeros , Suelo
6.
Appl Radiat Isot ; 109: 169-171, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26688358

RESUMEN

Within the Decay Data Evaluation Project (DDEP) and the IAEA Coordinated Research Project no. F41029, the evaluation of the nuclear decay data of (52)Fe, a radionuclide of interest in nuclear medicine, was performed. The main nuclear decay data evaluated are: the half-life, decay energy, energies and probabilities of the electron capture and ß(+) transitions, internal conversion coefficients and gamma-ray energies and emission intensities. This new evaluation, made using the DDEP methodology and tools, was included in the DDEP database NUCLEIDE.


Asunto(s)
Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/química , Radiometría/métodos , Radiometría/normas , Semivida , Radioisótopos de Hierro/normas , Valores de Referencia , Reproducibilidad de los Resultados , Rumanía , Sensibilidad y Especificidad
7.
J Environ Radioact ; 141: 164-73, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25617777

RESUMEN

The development of metrology of iron-55 in low-level radioactivity in environmental solid matrices was realised for conducting radioecological studies. A protocol was developed based on the adaptation of existing methods for the purification of iron-55 with selective chromatographic resin, which was then measured with liquid scintillation. The loss attached treatment chemical steps were quantified with elemental iron by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The tests were used to define the iron retention capacity of selective chromatographic resin, a key element in chemical treatment, and test sample size needed to reach the detection limit of 30 Bq kg(-1) dry. The solid samples were analysed with the developed protocol. The activities obtained from iron-55 were below the detection limit of 30 Bq kg(-1) dry.


Asunto(s)
Radioisótopos de Hierro/análisis , Monitoreo de Radiación/métodos , Conteo por Cintilación/métodos , Espectrofotometría Atómica/métodos , Límite de Detección
8.
Am J Clin Nutr ; 72(4): 982-9, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11010941

RESUMEN

BACKGROUND: Results of cross-sectional studies suggest that in healthy people, iron absorption adapts to meet physiologic needs and stabilize iron stores, but this has not been adequately tested in longitudinal studies. OBJECTIVE: We tested whether heme- and nonheme-iron absorption decrease in response to increased iron intake and whether iron stores reach a steady state. DESIGN: In a randomized, placebo-controlled trial, heme- and nonheme-iron absorption by healthy men and women (n = 57) were measured before and after 12 wk of supplementation with 50 mg Fe/d as ferrous sulfate. Serum and fecal ferritin were measured during supplementation and for 6 mo thereafter. RESULTS: Initially, both heme- and nonheme-iron absorption were inversely associated with serum ferritin concentration. Volunteers who took iron supplements, even those with serum ferritin <21 microg/L (n = 5), adapted to absorb less nonheme iron (3.2% at week 12 compared with 5.0% at week 0, P: < 0.001) but not less heme iron from a beef-based meal. Serum ferritin concentration was slightly but significantly higher after iron supplementation than after placebo (difference = 13 microg/L). This higher ferritin concentration persisted for >/=6 mo after supplementation, except in subjects with low iron stores, whose serum ferritin returned to baseline within 3 mo. Fecal ferritin excretion increased 2.5-fold (P: < 0.05) during supplementation. CONCLUSIONS: Healthy individuals, even those with low iron stores, had reduced nonheme-iron absorption from food in response to iron supplementation. Despite this partial adaptation, iron stores were greater after iron supplementation than after placebo and this difference was sustained, except in individuals with the lowest iron stores.


Asunto(s)
Adaptación Fisiológica/fisiología , Suplementos Dietéticos , Absorción Intestinal/fisiología , Hierro de la Dieta/farmacocinética , Hierro/fisiología , Adulto , Ensayo de Inmunoadsorción Enzimática , Heces/química , Femenino , Ferritinas/análisis , Hematócrito , Hemo/metabolismo , Hemoglobinas/análisis , Humanos , Hierro/análisis , Hierro/sangre , Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/sangre , Hierro de la Dieta/administración & dosificación , Masculino , Persona de Mediana Edad , Receptores de Transferrina/sangre , Conteo por Cintilación , Estadísticas no Paramétricas , Transferrina/análisis
9.
J Nucl Med ; 18(9): 937-9, 1977 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-893795

RESUMEN

Twenty-four hours after the administration of Ga-67 citrate and Fe-59 citrate, rabbits were killed and their livers removed and homogenized. Labile proteins in the filtered liver homogenates were denatured; ferritin was then crystallized from the supernatants by cadmium sulfate. Sephadex G-200 gel filtration of the ferritin fractions was done to determine the distribution of molecular weights in the substances associated with Ga-67 and Fe-59. It was found that Ga-67 was incorporated into the crystallizable ferritin fraction of rabbit hepatocytes with approximately one-sixth the uptake of simultaneously administered Fe-59. Gel-filtration chromatography confirmed that both the Ga-67 and the Fe-59 of the crystallizable ferritin fraction were associated with substances of the appropriate molecular weight for ferritin.


Asunto(s)
Ferritinas/análisis , Radioisótopos de Galio/análisis , Hígado/metabolismo , Animales , Radioisótopos de Hierro/análisis , Unión Proteica , Conejos
10.
Biol Trace Elem Res ; 43-45: 177-84, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-7710825

RESUMEN

The neutron activation analysis, gamma coincidence spectroscopy, nondispersive hydrogen flame atomic fluorescence spectroscopy, and Mössbauer spectrometry were used to study the low-selenium environment of the Exi Autonomous Prefecture, a well-known Keshan disease region. The Se contents in the soil samples there range from 0.075-0.18 mg/kg with the average of 0.13 mg/kg, whereas in the maize from 0.001-0.018 mg/kg with the average of 0.0099 mg/kg. The 57Fe Mössbauer spectrum of the soil indicates an anoxic environment. In addition to the FE3+ species the compounds containing low-valence iron e.g., goethite, and so forth, also exist. The rare earth element (REE) pattern obtained by NAA further confirms the reductive soil environment, which causes the selenium deficiency.


Asunto(s)
Selenio/análisis , Selenio/deficiencia , China , Humanos , Radioisótopos de Hierro/análisis , Análisis de Activación de Neutrones , Plantas/química , Suelo/análisis , Espectrofotometría Atómica , Espectroscopía de Mossbauer , Oligoelementos/análisis , Zea mays/química
11.
Health Phys ; 46(3): 511-27, 1984 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-6421771

RESUMEN

From June 1946 to August 1958, the U.S. Department of Defense and the U.S. Atomic Energy Commission (AEC) conducted nuclear weapons tests in the Northern Marshall Islands. On 1 March 1954, BRAVO, an above-ground test in the Castle series, produced high levels of radioactive material, some of which subsequently fell on Rongelap and Utirik Atolls due to an unexpected wind shift. On 3 March 1954, the inhabitants of these atolls were moved out of the affected area. They later returned to Utirik in June 1954 and to Rongelap in June 1957. Comprehensive environmental and personnel radiological monitoring programs were initiated in the mid 1950s by Brookhaven National Laboratory to ensure that body burdens of the exposed Marshallese subjects remained within AEC guidelines. Their body-burden histories and calculated activity ingestion rate patterns post-return are presented along with estimates of internal committed effective dose equivalents. External exposure data are also included. In addition, relationships between body burden or urine-activity concentration and declining continuous intake were developed. The implications of these studies are: (1) the dietary intake of 137Cs was a major component contributing to the committed effective dose equivalent for the years after the initial contamination of the atolls; (2) for persons whose diet included fish, 65Zn was a major component of committed effective dose equivalent during the first years post-return; (3) a decline in the daily activity ingestion rate greater than that resulting from radioactive decay of the source was estimated for 137Cs, 65Zn, 90Sr and 60Co; (4) the relative impact of each nuclide on the estimate of committed effective dose equivalent was dependent upon the time interval between initial contamination and rehabilitation; and (5) the internal committed effective dose equivalent exceeded the external dose equivalent by a factor of 1.1 at Utirik and 1.5 at Rongelap during the rehabitation period. Few reliable 239Pu measurements on human excreta were made. An analysis of the tentative data leads to the conclusion that a reliable estimate of committed effective dose equivalent requires further research.


Asunto(s)
Ceniza Radiactiva/análisis , Radioisótopos/análisis , Adulto , Carga Corporal (Radioterapia) , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Femenino , Humanos , Radioisótopos de Hierro/análisis , Masculino , Micronesia , Plutonio/análisis , Radioisótopos de Estroncio/análisis , Factores de Tiempo , Recuento Corporal Total , Radioisótopos de Zinc/análisis
12.
Appl Radiat Isot ; 60(2-4): 447-51, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14987683

RESUMEN

Ionization quench function Q(E) introduces an important correction in the CIEMAT/NIST tracing method. In this paper we present a detailed analysis of the equations used to compute the counting efficiency of 55Fe. The counting efficiency of this radionuclide is very sensitive to the shape and values of Q(E) for this method. We demonstrate that the Birks equation and stopping power are not adequate to obtain low discrepancies between the experimental and computed efficiencies. An empirical procedure to compute accurate Q(E) functions is also given.


Asunto(s)
Algoritmos , Radioisótopos de Hierro/análisis , Transferencia Lineal de Energía , Modelos Químicos , Modelos Estadísticos , Radiación Ionizante , Conteo por Cintilación/métodos , Radiometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Soluciones
13.
Appl Radiat Isot ; 48(6): 735-8, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9204525

RESUMEN

After the transfer of the thick copper target plate irradiated with 30 MeV protons from a medical cyclotron, the gamma dose rate in the target cave was monitored every minute for 25 hours using wall-mounted gamma area monitors. The dose rate decay curve was fitted with four exponential functions. By analysing the slope of the exponentials the traces of radioactive 28Al, 56Mn 24Na and 59Fe were identified. The results were used to minimise personnel radiation exposure during maintenance work on the cyclotron.


Asunto(s)
Ciclotrones/instrumentación , Aluminio/análisis , Cobre , Rayos gamma , Semivida , Humanos , Radioisótopos de Hierro/análisis , Manganeso/análisis , Exposición Profesional/prevención & control , Protones , Monitoreo de Radiación , Radioisótopos/análisis , Radioisótopos de Sodio/análisis
14.
Appl Radiat Isot ; 54(1): 113-22, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11144241

RESUMEN

The positron emitter 18F continues to be one of the most important imaging radionuclides in diagnostic nuclear medicine. Assays of radiopharmaceuticals containing this nuclide are often performed in the clinic using commercial reentrant ionization chambers, or "dose calibrators". Meaningful quantitative clinical studies require accurate knowledge of the injected activity which requires proper calibration of these instruments. Radioassays were performed at the National Institute of Standards and Technology (NIST) on a solution of 18F produced at the National Institutes of Health (NIH) using 4pibeta liquid scintillation (fS) counting with 3H-standard efficiency tracing. Cocktails containing water fractions of approximately 0.9 and 9% (both as saline) were used. The massic activity values were measured to be 2.52+/-0.06 and 2.50+/-0.03 MBq g(-1), respectively, for the 0.9 and 9% water cocktails as of the reference time. The uncertainties on the activity measurements are expanded (k = 2) uncertainties. The largest uncertainty component was found to be the repeatability on a single LS source, with the cocktails containing 0.9% water fraction exhibiting a larger variability by nearly a factor of two. Reproducibility between LS cocktails with the same water fraction was also found to be a large uncertainty component, but with a value less than half that due to measurement repeatability. Radionuclidic impurities consisted of 48V and 46Sc, at levels of 0.11+/-0.08% (expanded uncertainties) and approximately 2 x 10(-3)% (upper limit) relative to the activity of the 18F, as of the reference time. Dose calibrator dial settings for measuring solutions of 18F were experimentally determined for Capintec CRC-12 and CRC-35R dose calibrators in three measurement geometries: a 5-ml standard NIST ampoule (two ampoules measured), a 12-ml plastic syringe containing 9 ml of solution and a 10-ml Mallinckrodt molded dose vial filled with 5 ml of solution. The experimental dial settings (and the corresponding expanded uncertainties) for these geometries were found to be 477+/-7, 474+/-6, 482+/-6 and 463+/-7 for the two ampoules, the syringe and the dose vial, respectively, in the CRC-12. The dial settings determined for the CRC-35R were 472+/-7, 470+/-7, 464+/-6 and 456+/-6 for the two ampoules, the syringe, and the dose vial, respectively. The uncertainties in the dial settings are expanded uncertainties. Comparisons between the empirically determined dial settings and the manufacturer's recommended setting of "439" indicate that use of the manufacturer's setting overestimates the activity by between 3 and 6%, depending upon the geometry used.


Asunto(s)
Radioisótopos de Flúor/análisis , Radioisótopos de Hierro/análisis , Radiometría/instrumentación , Radiofármacos/química , Calibración , Rayos gamma , National Institutes of Health (U.S.) , Radiometría/métodos , Radiofármacos/análisis , Reproducibilidad de los Resultados , Estados Unidos
15.
Appl Radiat Isot ; 60(2-4): 453-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14987684

RESUMEN

In the case of high-quenched 3H and 63Ni sources a distinct incompatibility of theoretical and experimental detection efficiency in the triple liquid scintillation (LS) detector was observed (Appl. Radiat. Isot. 52 (2000) 643). The authors concluded, that the Poisson distribution does not properly describe the detection process, when less than one photoelectron is expected in one of the photomultipliers. Application of other distributions of photoelectrons, e.g. binomial, does not solve the observable problem of incompatibility. Measurements of a set of 55Fe sources have been performed with phototubes defocusing and grey filters for decreasing the counting efficiency of the TDCR detector. Differences between counting results of the 55Fe source and the light emitting diode (LED), simulating the scintillation source, excited by a pulse generator have been observed. Various distributions (Poisson, binomial and Polya) were used for the determination of the theoretical counting efficiency in both cases. The Poisson law gave a good result in the case of the LED but the Polya law had to be applied in the case of 55Fe. The results were independent of the scintillator volume. It seems that the validity of the Polya law in the case of LS-sources is related to the scintillator itself. Measurements of the 3H solution confirmed that conclusion.


Asunto(s)
Algoritmos , Radioisótopos de Hierro/análisis , Transferencia Lineal de Energía , Modelos Químicos , Modelos Estadísticos , Conteo por Cintilación/instrumentación , Conteo por Cintilación/métodos , Tritio/análisis , Análisis de Falla de Equipo , Radiometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Soluciones
16.
Appl Radiat Isot ; 60(2-4): 459-64, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14987685

RESUMEN

Liquid scintillation counting techniques combined with the CIEMAT/NIST method have been applied to measure the specific activity of natural potassium salts. Samples have been prepared with three different scintillators. The individual atomic composition as well as the density of the cocktails have been taken into account for the efficiency calculation. With the specific activity the half-life is calculated to be T1/2 = 1.248(3) x 10(9) a. The result is in reasonable agreement with other measurement results provided the same isotopic concentration of 40K is used.


Asunto(s)
Algoritmos , Radioisótopos de Hierro/análisis , Modelos Químicos , Modelos Estadísticos , Radioisótopos de Potasio/análisis , Radioisótopos de Potasio/normas , Radiación Ionizante , Conteo por Cintilación/métodos , Semivida , Transferencia Lineal de Energía , Radiometría/métodos , Reproducibilidad de los Resultados , Conteo por Cintilación/normas , Sensibilidad y Especificidad , Soluciones
17.
Appl Radiat Isot ; 51(6): 707-15, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10581681

RESUMEN

Quantification accuracy in positron emission tomography (PET) using non-pure positron emitters, such as 52Fe, may be influenced by gamma radiation emitted in the decay of these isotopes. High-energy positrons, emitted in the decay of the 52Fe-daughter 52mMn, also affect the quantification accuracy. A specific problem of the 52Fe/52mMn decay chain in vivo is that the kinetics of iron and manganese are different, and that PET cannot discriminate between the two nuclides. The effect of the decay properties of 52Fe/52mMn on the performance of PET was investigated using phantoms. Minor degradation in PET performance was found for 52Fe/52mMn compared to the pure low-energy positron emitter 18F. A method is presented to obtain a correction factor for the 52mMn radioactivity in blood. A model for correction of 52mMn-radioactivity in organs, based on existing data on manganese kinetics, is given. The presented corrections are discussed and illustrated in a patient study.


Asunto(s)
Radioisótopos de Hierro/análisis , Radiofármacos/farmacocinética , Tomografía Computarizada de Emisión/métodos , Adulto , Médula Ósea/diagnóstico por imagen , Médula Ósea/metabolismo , Femenino , Compuestos Férricos/administración & dosificación , Compuestos Férricos/sangre , Compuestos Férricos/farmacocinética , Sacarato de Óxido Férrico , Ácido Glucárico , Corazón/diagnóstico por imagen , Humanos , Hígado/diagnóstico por imagen , Hígado/metabolismo , Miocardio/metabolismo , Fantasmas de Imagen , Radiofármacos/administración & dosificación , Radiofármacos/sangre , Bazo/diagnóstico por imagen , Bazo/metabolismo , Distribución Tisular
18.
Appl Radiat Isot ; 81: 42-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23566806

RESUMEN

The obtained results showed that the Sr resin can be used for the chromatographic separation of Fe (III) and Sr (II) ions by using a mixture of HCl and HNO3. It was shown that the binding strength of Fe (III) decreases with increasing concentration of HNO3 while the binding strength of Sr (II) increases. It was found that the optimal bonding strength is achieved in 6 mol/L HCl:3 mol/L HNO3 and varying concentrations of acid in the mixture allow their selective separation. On basis of these results, a method for the separation of (55)Fe and (89,90)Sr from liquid samples which consists of binding of Fe and Sr on Sr resin and separation from a number of elements by 6 mol/L HCl:3 mol/L HNO3 and their mutual separation by eluting of Sr with 4 mol/L HCl is established. The method enables efficient simultaneous separation (with high recovery) of (89,90)Sr and (55)Fe and in combination with Cerenkov counting rapid determination of (89,90)Sr.


Asunto(s)
Fraccionamiento Químico/métodos , Radioisótopos de Hierro/análisis , Radiometría/métodos , Soluciones/química , Radioisótopos de Estroncio/análisis , Ultrafiltración/métodos , Absorción , Resinas Acrílicas/química , Ácido Clorhídrico/química , Hierro/aislamiento & purificación , Ácido Nítrico/química , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Estroncio/aislamiento & purificación
19.
Appl Radiat Isot ; 70(1): 269-73, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21890368

RESUMEN

We report on the study of the intensities of several gamma lines emitted after the inelastic scattering of neutrons in (56)Fe. Neutrons were produced via nuclear processes induced by cosmic muons in the 20tons massive iron cube placed at the Earth's surface and used as a passive shield for the HPGe detector. Relative intensities of detected gamma lines are compared with the results collected in the same iron shield by the use of the (252)Cf neutrons. Assessment against the published data from neutron scattering experiments at energies up to 14MeV is also provided. It allowed us to infer the qualitative information about the average energy of muon-created neutrons in the iron shield.


Asunto(s)
Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/química , Hierro , Modelos Químicos , Neutrones , Radiometría/métodos , Dispersión de Radiación , Simulación por Computador , Mesones , Dosis de Radiación
20.
Appl Radiat Isot ; 70(9): 1863-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22405638

RESUMEN

The implementation of (63)Ni and (55)Fe determination methods in an environmental laboratory implies their validation. In this process, the uncertainties related to these methods should be analysed. In this work, the expression of the uncertainty of the results obtained using separation methods followed by liquid scintillation counting is presented. This analysis includes the consideration of uncertainties coming from the different alternatives which these methods use as well as those which are specific to the individual laboratory and the competency of its operators in applying the standard ORISE (Oak Ridge Institute for Science and Education) methods.


Asunto(s)
Radioisótopos de Hierro/análisis , Radioisótopos de Hierro/química , Níquel/análisis , Níquel/química , Conteo por Cintilación/métodos , Conteo por Cintilación/normas , Internacionalidad , Dosis de Radiación , Estándares de Referencia , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda