Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 446
Filtrar
Más filtros

Publication year range
1.
Optom Vis Sci ; 101(6): 417-423, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38990240

RESUMEN

SIGNIFICANCE: Individuals with reduced visual acuity (VA) may drive with bioptic telescopes in some jurisdictions. The effect of bioptic telescope use on on-road recognition distances is important for driving safety, as increased recognition distances increase the time available to react to road signs or driving events. PURPOSE: This study aimed to investigate the impact of bioptic telescope use on visual recognition of road signs, traffic lights, and hazards in an on-road driving environment in individuals with reduced VA. METHODS: Ten individuals (mean ± standard deviation age, 39.1 ± 19.1 years) with reduced VA (trained to use bioptic telescopes) participated in a repeated-measures on-road experiment for two viewing conditions, with and without a bioptic telescope (randomized order). Participants underwent a clinical low vision assessment, including high-contrast VA with and without the bioptic telescope aligned, visual fields, and contrast sensitivity testing. For the driving component, participants seated in the front passenger seat of a moving car reported all road signs, traffic lights, and hazards (unpredictable road events that represent a risk to driving safety including other vehicles, cyclists, pedestrians) seen along a route that included suburban roads and highways. Video cameras captured participants' viewing behavior, verbal commentary, and the distance at which three pre-selected road signs were reported. RESULTS: In the eye with the bioptic telescope, high-contrast VA improved from 0.75 ± 0.17 (without) to 0.25 ± 0.1 logMAR with the bioptic telescope. Bioptic telescope use did not affect the percentage of road signs, traffic lights, or hazards correctly recognized but did result in 2.6 times longer recognition distances (49 ± 23 vs. 19 ± 11 m, t9 = 5.02, p<0.001). CONCLUSIONS: Road signs were recognized at significantly longer distances when using a bioptic telescope, confirming their positive impact on timely visual recognition of objects within the driving scene. Future work should explore whether this effect generalizes to individuals using bioptic telescopes when driving a vehicle.


Asunto(s)
Conducción de Automóvil , Telescopios , Baja Visión , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Adulto , Masculino , Femenino , Baja Visión/fisiopatología , Baja Visión/rehabilitación , Persona de Mediana Edad , Adulto Joven , Diseño de Equipo , Percepción Visual/fisiología , Sensibilidad de Contraste/fisiología , Campos Visuales/fisiología
2.
Lasers Med Sci ; 39(1): 33, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38231430

RESUMEN

As the demand for CO[Formula: see text] laser surgeries continues to grow, the quality of their main instrument, the laser micromanipulator, becomes increasingly important. However, in many surgery systems, a large ratio of the laser power is wasted due to the reflection from the mirror of a telescopic system, like a Cassegrain telescope, back to the laser side, which not only decreases the system's efficiency but can also damage the system itself. In this article, we introduce a new design of the micromanipulator telescope for CO[Formula: see text] laser surgery, which employs a Bessel beam to improve the system efficiency. As in the propagation of a Bessel beam, the power of the light beam can be transferred from the center to a ring shape, the whole power reflected from the first mirror can reach the second mirror and no power goes back to the second mirror hole. The micromanipulator telescope design and optimization are carried out using Zemax Optics Studio, and the integration of the Bessel beam into the system is implemented using MATLAB. Our simulation results show that by applying the appropriate Bessel beam, the system efficiency can reach more than 96%, and the normalized peak irradiance can increase by 40 to 73% for various working distances. In addition to increasing the system efficiency and normalized peak irradiance, resulting in a sharper surgical blade, the use of the Bessel beam enhances the depth of focus, making the system less sensitive to depth misalignment.


Asunto(s)
Telescopios , Simulación por Computador , Reproducción
3.
Phys Rev Lett ; 130(21): 211001, 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37295105

RESUMEN

We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical "drift model" of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.


Asunto(s)
Radiación Cósmica , Vuelo Espacial , Telescopios , Protones , Electrones
4.
Nature ; 612(7940): 381, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36517710
7.
Sensors (Basel) ; 23(13)2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37447916

RESUMEN

Linear active disturbance rejection control (LADRC) has been widely used to improve the tracking accuracy and anti-disturbance performance of telescope servo control under disturbances. However, the linear extended state observer (LESO) is sensitive to noise, and its bandwidth is limited by the resonant frequency of the telescope. To enhance the LARDC's ability to attenuate disturbances, a novel cascade anti-disturbance structure (NCADS) with LADRC on the outer speed loop and a nonlinear disturbance observer (NDOB) on the inner current loop is proposed. The NDOB compensates for the dominant disturbance through feedforwarding the q-axis current reference, and the LESO compensates for the residual disturbance on the outer speed loop. First, the NCADS is introduced in a three-closed-loop control framework of PMSM. Then, the design method of the controller for each loop and the NDOB are presented, the parameter-tuning method based on bandwidth is demonstrated, and the convergence of the NDOB is proved. Furthermore, to improve the searching and tracking efficiency of wide-field survey telescopes, the nonlinear tracking differentiator (NTD) was modified to plan the transition process of the position loop, which only needs to set the maximum speed and acceleration of the telescope. Finally, simulations and experiments were performed on a 2.5-m-wide field survey telescope. The experimental results verify that the proposed NCADS method has a better anti-disturbance performance and higher tracking precision than the conventional method, and the improved NTD method does not need to tune parameters and achieved a fast and smooth transition process of the position loop.


Asunto(s)
Telescopios , Proyectos de Investigación , Aceleración
8.
Artículo en Inglés, Ruso | MEDLINE | ID: mdl-37830466

RESUMEN

3D exoscopy based on Video Telescope Operating Monitor (VITOM) technology provides good visualization quality and portability. There are few data on comparison of extracorporeal telescoping with microsurgical techniques in spinal surgery. OBJECTIVE: To compare the effectiveness of VITOM 3D exoscopy and microsurgical techniques in spinal surgery. MATERIAL AND METHODS: A prospective study included 80 patients (54 men and 26 women). Two groups were distinguished: group 1 (ES, n=40) - VITOM 3D exoscopy, group 2 (SM, n=40) - Pentero 900 surgical microscope. We analyzed surgery time, postoperative rehabilitation, hospital-stay and complications. ES and microsurgical technique were compared using the questionnaire by Takahashi S. and rapid upper limb assessment (RULA). RESULTS: Conventional microsurgical technique was characterized by less surgery time (p<0.05) and morbidity (p=0.02). Postoperative rehabilitation and hospital-stay were similar (p=0.26 and p=0.39, respectively). Image quality in ES was comparable to microsurgical technique in shallow accesses and manipulations perpendicular to skin incision. Availability of neurosurgical instruments at different depths of the wound channel was comparable in both groups. The limitation of ES was length of skin incision, depth of the wound and its visualization at certain angle. These features required expansion of surgical approach or conversion of intervention. In general, surgeons rated intraoperative posture comfort as comparable in both groups that was consistent with the RULA scale. CONCLUSION: VITOM 3D exoscopy is an alternative to traditional microscopy and more ergonomically beneficial in spinal surgery in case of manipulations perpendicular to skin incision and shallow wide accesses. There are several important limitations of this device including difficult manipulations in narrow deep wounds and visualization under certain angle.


Asunto(s)
Telescopios , Masculino , Humanos , Femenino , Estudios Prospectivos , Procedimientos Neuroquirúrgicos/métodos , Microcirugia/métodos
9.
Nature ; 529(7584): 59-62, 2016 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-26675732

RESUMEN

Thousands of transiting exoplanets have been discovered, but spectral analysis of their atmospheres has so far been dominated by a small number of exoplanets and data spanning relatively narrow wavelength ranges (such as 1.1-1.7 micrometres). Recent studies show that some hot-Jupiter exoplanets have much weaker water absorption features in their near-infrared spectra than predicted. The low amplitude of water signatures could be explained by very low water abundances, which may be a sign that water was depleted in the protoplanetary disk at the planet's formation location, but it is unclear whether this level of depletion can actually occur. Alternatively, these weak signals could be the result of obscuration by clouds or hazes, as found in some optical spectra. Here we report results from a comparative study of ten hot Jupiters covering the wavelength range 0.3-5 micrometres, which allows us to resolve both the optical scattering and infrared molecular absorption spectroscopically. Our results reveal a diverse group of hot Jupiters that exhibit a continuum from clear to cloudy atmospheres. We find that the difference between the planetary radius measured at optical and infrared wavelengths is an effective metric for distinguishing different atmosphere types. The difference correlates with the spectral strength of water, so that strong water absorption lines are seen in clear-atmosphere planets and the weakest features are associated with clouds and hazes. This result strongly suggests that primordial water depletion during formation is unlikely and that clouds and hazes are the cause of weaker spectral signatures.


Asunto(s)
Atmósfera/química , Medio Ambiente Extraterrestre/química , Planetas , Agua/análisis , Júpiter , Presión , Espectrofotometría Infrarroja , Telescopios , Temperatura
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda