Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Clin Chem Lab Med ; 58(4): 605-617, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-31874092

RESUMEN

Background Accurate pediatric reference intervals (RIs) for laboratory tests determined in a healthy pediatric population are essential for correct laboratory test interpretation and clinical decision-making. In pediatrics, RIs require partitioning by age and/or sex; however, the need for partitioning based on ethnicity is unclear. Here, we assessed the influence of ethnicity on biomarker concentrations in the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort of healthy children and adolescents and compared the results with the National Health and Nutrition Examination Survey (NHANES). Methods A total of 52 biomarkers were measured in a multiethnic population of 846-1179 healthy children (aged 5 to <19 years) upon informed consent. Biomarker concentrations were retrospectively compared between four major ethnic groups (i.e. Black, Caucasian, East Asian, and South Asian, determined by parental ethnicity). Retrospective results were verified prospectively using an additional 500 healthy pediatric samples with equal sample size across ethnicities. Ethnic-specific differences were assessed based on statistical significance and biological and analytical variations. Appropriate age-, sex-, and ethnic-specific RIs were calculated. Results Ethnic-specific differences were not observed for 34 biomarkers examined in the retrospective analysis, while 18 demonstrated statistically significant ethnic differences. Among these, seven analytes demonstrated ethnic-specific differences in the prospective analysis: vitamin D, amylase, ferritin, follicle-stimulating hormone (FSH), immunoglobulin A (IgA), immunoglobulin G (IgG), and immunoglobulin M (IgM). Analysis of select NHANES data confirmed CALIPER findings. Conclusions This is the first comprehensive Canadian pediatric study examining ethnic-specific differences in common biomarkers. While the majority of biomarkers did not require ethnic partitioning, ethnic-specific RIs were established for seven biomarkers showing marked differences. Further studies in other populations are needed to confirm our findings.


Asunto(s)
Biomarcadores/análisis , Etnicidad , Adolescente , Amilasas/análisis , Amilasas/normas , Canadá , Niño , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Hormona Folículo Estimulante/análisis , Hormona Folículo Estimulante/normas , Humanos , Masculino , Valores de Referencia , Estudios Retrospectivos , Vitamina D/análisis , Vitamina D/normas
2.
Clin Chem Lab Med ; 58(5): 817-827, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-31348755

RESUMEN

Background The current millennium has seen an explosion in vitamin D testing with the overarching aim of requests to clinically stratify patients as replete or deficient in vitamin D. At a population level, dried blood spot (DBS) sampling offers a less invasive and more practical application for assessment of vitamin D status. We have therefore aimed to develop a sensitive and robust DBS vitamin D method that is traceable to serum for use in population-based studies. Methods Blood spots, calibrators and controls were prepared by punching a 3.2 mm DBS from filter paper and placed into a 96-well micro-plate. The DBS disk was eluted with a combination of water-methanol and internal standard (ISTD) solution followed by supported-liquid extraction and derivatisation. The extract was analysed by liquid-chromatography tandem-mass spectrometry in positive electrospray-ionisation mode with 732.5 > 673.4 and 738.4 > 679.4 m/z ion-transitions for derivatised vitamin D and the ISTD, respectively. Vitamin D results were made traceable to the National Institute of Standards and Technology reference material through the inclusion of Chromsystems vitamin D calibrators. Results 25-Hydroxy-vitamin D3 and its related ISTD were detected at a retention time of 7 min. The seven-point calibration-curve consistently demonstrated a coefficient of determination of 0.99 with an experimentally determined reportable range of 0.5-376 nmol/L. Method validation studies using DBS samples demonstrated 12.9% between-assay imprecision at 45 nmol/L, 84% average recovery and high correlation with plasma vitamin D (correlation coefficient = 0.86). Conclusions We have successfully developed an analytical method for vitamin D quantitation from DBSs which will be applied to our population-based vitamin D research study. This approach improves traceability of DBS results and potentially could be used broadly for other DBS measurands that require comparison to serum/plasma for their interpretation.


Asunto(s)
Pruebas con Sangre Seca , Vitamina D/sangre , Adolescente , Adulto , Anciano , Calcifediol/sangre , Calcifediol/química , Calibración , Niño , Preescolar , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/normas , Pruebas con Sangre Seca/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Triazoles/química , Vitamina D/normas , Adulto Joven
3.
Anal Bioanal Chem ; 412(2): 365-375, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31832707

RESUMEN

A novel method to quantitate vitamin D and its main metabolites (vitamin D3, vitamin D2, and their 25-hydroxy metabolites) in breast milk by supercritical fluid chromatography has been developed and fully validated. A small volume of sample (1 mL) is subjected to ethanolic protein precipitation and liquid-liquid extraction. Final extracts are derivatized with 4-phenyl-1,2,4-triazoline-3,5-dione and vitamin D derivatives analyzed by supercritical fluid chromatography hyphenated to tandem mass spectrometry with atmospheric pressure chemical ionization. Multiple reaction monitoring is used for quantitation. Separation conditions were optimized using a gradient of methanol-water-ammonium formate into carbon dioxide. Make-up solvent was methanol containing ammonium formate. The quantitation limit reached levels as low as 50 pmol/L, with intra- and inter-day relative standard deviations lower than 15% and 20% for all analytes. Accuracy was evaluated by spiking experiments and was well within acceptability ratios (± 15%). The method was then applied to a subset of commercially available human milk samples. The newly developed method provides opportunities to determine the nutritional status of mother-infant dyads from a non-invasive measure, or for interventional or observational studies building knowledge on the composition of human milk. Graphical abstract.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Leche Humana/metabolismo , Espectrometría de Masas en Tándem/métodos , Vitamina D/metabolismo , Calibración , Femenino , Humanos , Recién Nacido , Límite de Detección , Estándares de Referencia , Vitamina D/normas
4.
Clin Endocrinol (Oxf) ; 90(1): 222-231, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30067874

RESUMEN

OBJECTIVES: It is well established that UK Asians typically have lower vitamin D levels than Caucasians. It is also known that vitamin D binding protein (DBP) is lower in some races than Caucasians. To investigate how ethnicity, skin colour and genetic variation affect the response to vitamin D (15000 IU) administered to young Asian and Caucasian men. DESIGN: Prospective, single-centre clinical trial. PARTICIPANTS: Sixty young men (18-25 year) of Asian (n = 30) and Caucasian (n = 30) origin. MEASUREMENTS: We measured serum calcium, phosphate, magnesium, alkaline phosphatase, albumin, parathyroid hormone; total 25 hydroxyvitamin D (25OHD); calculated and directly measured free 25OHD; DBP at baseline and 4 weeks; DBP genotype, skin colour (Fitzpatrick scale), dietary vitamin D and calcium intake at baseline; and urine calcium:creatinine ratio at baseline, 1 and 4 weeks. RESULTS: At baseline, Asians had lower serum total 25OHD (26.4 [13.7] vs 34.1 [12.3] nmol/L P = 0.0272) and DBP (6.7 [3.4] vs 9.6 [4.4] nmol/L; P = 0.0065) but similar free 25OHD (16.7 [10.4] vs 17.8 [7.5] pmol/L P = 0.6530). After dosing, total 25OHD rose similarly in each group (≈56 nmol/L), but measured free 25OHD rose more in Asians (18.1 [9.4] vs 12.2 [13.3] pmol/L P = 0.0464). Lower DBP at baseline, possibly reflecting genotype differences, was associated with a greater change in measured free 25OHD in Caucasians, but not in Asians. CONCLUSIONS: Asian compared with Caucasian males had a larger increment in measured free 25OHD following 150 000 units vitamin D3, possibly reflecting differences in DBP affinity for 25OHD. Ethnicity should be considered when devising guidelines for the treatment of vitamin D deficiency.


Asunto(s)
Pueblo Asiatico , Deficiencia de Vitamina D/etnología , Vitamina D/sangre , Población Blanca , Adolescente , Adulto , Suplementos Dietéticos , Humanos , Masculino , Reino Unido , Vitamina D/normas , Vitamina D/uso terapéutico , Deficiencia de Vitamina D/sangre , Adulto Joven
5.
J Pediatr Gastroenterol Nutr ; 68(1): 110-115, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30095576

RESUMEN

CONTEXT: In 2012, The North American Cystic Fibrosis Foundation (NACFF) published new guidelines for the treatment of vitamin D deficiency in individuals with cystic fibrosis (CF). OBJECTIVE: The objectives of our study were to assess the efficacy of these guidelines, and to test the effect of increasing vitamin D dosage on pulmonary function and exacerbations. DESIGN: Pulmonary function tests and serum concentrations of 25-hydroxyvitamin D [25(OH)D] were measured 1 year before increasing vitamin D dosage according to the guidelines and at least 1 year later. In addition, days of hospitalization and pulmonary exacerbations were counted and an average per year (average number of days of hospitalization and average number of pulmonary exacerbations [PEA], respectively) was calculated. SETTING AND PARTICIPANTS: A total of 90 patients from The Cystic Fibrosis Clinic at Hadassah Mount-Scopus Hospital, Jerusalem, Israel. RESULTS: The mean serum concentration of vitamin D increased significantly from 20.97 ng/mL (52.34 nmol/L) at baseline to 25.41 ng/mL (63.42 nmol/L) at the end of follow-up (P < 0.001). The number of PEA decreased significantly from 2.79 ±â€Š3.96 to 2.15 ±â€Š2.91 (P = 0.007). The change in vitamin D levels was correlated with a decrease in PEA (correlation coefficient = -0.318, P = 0.002). CONCLUSIONS: The NACFF guidelines for management of vitamin D deficiency improve vitamin D levels in patients with CF but did not reach the normal values in most patients. The increase in vitamin D serum levels was, however, associated with a decrease in number of pulmonary exacerbations.


Asunto(s)
Fibrosis Quística/sangre , Suplementos Dietéticos , Progresión de la Enfermedad , Deficiencia de Vitamina D/terapia , Vitamina D/análogos & derivados , Adolescente , Niño , Preescolar , Fibrosis Quística/complicaciones , Fibrosis Quística/fisiopatología , Suplementos Dietéticos/normas , Femenino , Estudios de Seguimiento , Humanos , Lactante , Tiempo de Internación/estadística & datos numéricos , Pulmón/fisiopatología , Masculino , Guías de Práctica Clínica como Asunto , Pruebas de Función Respiratoria , Resultado del Tratamiento , Vitamina D/administración & dosificación , Vitamina D/sangre , Vitamina D/normas , Deficiencia de Vitamina D/etiología , Deficiencia de Vitamina D/fisiopatología , Vitaminas/administración & dosificación , Vitaminas/normas
6.
Br J Clin Pharmacol ; 84(10): 2194-2207, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29851137

RESUMEN

The First International Conference on Controversies in Vitamin D was held in Pisa, Italy, 14-16 June 2017. The meeting's purpose was to address controversies in vitamin D research, review the data available, to help resolve them, and suggest a research agenda to clarify areas of uncertainty. The serum 25-hydroxyvitamin D [25(OH)D] concentration [i.e. the sum of 25(OH)D3 and 25(OH)D2 ] remains the critical measurement for defining vitamin D status. Assay variation for 25(OH)D has contributed to the current chaos surrounding efforts to define hypovitaminosis D. An essential requirement to develop a consensus on vitamin D status is that measurement of 25(OH)D and, in the future, other potential vitamin D biomarkers [e.g. 1α,25(OH)2 D3 , 3-epi-25(OH)D, 24,25(OH)2 D3, vitamin D-binding protein, free/bioavailable 25(OH)D and parathyroid hormone] be standardized/harmonized, to allow pooling of research data. Vitamin D Standardization Program tools are described and recommended for standardizing 25(OH)D measurement in research. In the future, similar methodology, based on National Institute for Standards and Technology standard reference materials, must be developed for other candidate markers of vitamin D status. Failure to standardize/harmonize vitamin D metabolite measurements is destined to promulgate continued chaos. At this time, 25(OH)D values below 12 ng ml-1 (30 nmol l-1 ) should be considered to be associated with an increased risk of rickets/osteomalacia, whereas 25(OH)D concentrations between 20 ng ml-1 and 50 ng ml-1 (50-125 nmol l-1 ) appear to be safe and sufficient in the general population for skeletal health. In an effort to bridge knowledge gaps in defining hypovitaminosis D, an international study on rickets as a multifactorial disease is proposed.


Asunto(s)
Conferencias de Consenso como Asunto , Guías de Práctica Clínica como Asunto , Deficiencia de Vitamina D/diagnóstico , Vitamina D/sangre , Factor-23 de Crecimiento de Fibroblastos , Humanos , Estándares de Referencia , Vitamina D/normas , Deficiencia de Vitamina D/sangre
7.
Allergy Asthma Proc ; 38(3): 21-28, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28441981

RESUMEN

BACKGROUND: Vitamin D insufficiency has been associated with immune dysfunction and linked to the epidemic of atopic diseases in the Western hemisphere, yet there are studies with conflicting results, and the risk has not been quantified uniformly across studies. OBJECTIVE: To perform a systematic review and meta-analysis to evaluate and quantify if vitamin D deficiency is associated with the presence and persistence of food allergy. METHODS: A systematic review was undertaken to assess for the association between food allergy and vitamin D status in children. RESULTS: A total of 368 citations relevant to this systematic review were identified. In the whole review, 5105 children were included. We did not find a significant association between 25 hydroxy vitamin D (25(OH)D) status and risk of food allergy in children (odds ratio [OR] 1.35 [95% confidence interval {CI}, 0.79-2.29]; p = 0.27, I2 = 58.3%). We conducted subgroup analyses based on different cutoffs of the 25(OH)D status (20 versus 30 ng/mL). Only one study used 30 ng/mL and found that children with <30 ng/mL were more likely to report food allergy than children with a 25(OH)D status of ≥30 ng/mL (OR 2.04 [95% CI, 1.02-4.04]; p = 0.04). Four studies compared children with a 25(OH)D status of <20 ng/mL to children with a 25(OH)D status of ≥20 ng/mL and found no significant differences (OR 1.18 [95% CI, 0.62-2.27]; p = 0.62, I2 = 62.7%). CONCLUSION: Based on the studies analyzed, this systematic review did not identify a significant association between vitamin D status and food allergy. Interpretation of the included studies was limited by a lack of a standard definition for vitamin D deficiency and insufficient knowledge regarding the optimal vitamin D status needed to impact immune function. Longitudinal studies are warranted to assess if vitamin D might contribute to the development of food allergy.


Asunto(s)
Hipersensibilidad a los Alimentos/etiología , Deficiencia de Vitamina D/complicaciones , Vitamina D/normas , Niño , Humanos , Oportunidad Relativa , Vitamina D/inmunología
8.
Clin Chem Lab Med ; 54(2): 293-303, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26088062

RESUMEN

BACKGROUND: The aims of this study were to establish robust reference intervals and to investigate the factors influencing bone turnover markers (BTMs) in healthy premenopausal Spanish women. METHODS: A total of 184 women (35-45 years) from 13 centers in Catalonia were analyzed. Blood and second void urine samples were collected between 8 a.m. and 10 a.m. after an overnight fast. Serum procollagen type I amino-terminal propeptide (PINP) and serum cross-linked C-terminal telopeptide of type I collagen (CTX-I) were measured by two automated assays (Roche and IDS), bone alkaline phosphatase (bone ALP) by ELISA, osteocalcin (OC) by IRMA and urinary NTX-I by ELISA. PTH and 25-hydroxyvitamin D (25OHD) levels were measured. All participants completed a questionnaire on lifestyle factors. RESULTS: Reference intervals were: PINP: 22.7-63.1 and 21.8-65.5 µg/L, bone ALP: 6.0-13.6 µg/L, OC: 8.0-23.0 µg/L, CTX-I: 137-484 and 109-544 ng/L and NTX-I: 19.6-68.9 nM/mM. Oral contraceptive pills (OCPs) influenced PINP (p=0.007), and low body mass index (BMI) was associated with higher BTMs except for bone ALP. Women under 40 had higher median values of most BTMs. CTX-I was influenced by calcium intake (p=0.010) and PTH (p=0.007). 25OHD levels did not influence BTMs. Concordance between the two automated assays for PINP and particularly CTX-I was poor. CONCLUSIONS: Robust reference intervals for BTMs in a Southern European country are provided. The effects of OCPs and BMI on their levels are significant, whilst serum 25OHD levels did not influence BTMs. Age, calcium intake, BMI and PTH influenced CTX-I. The two automated assays for measuring PINP and CTX-I are not interchangeable.


Asunto(s)
Biomarcadores/sangre , Remodelación Ósea , Ensayo de Inmunoadsorción Enzimática , Adulto , Fosfatasa Alcalina/análisis , Fosfatasa Alcalina/normas , Biomarcadores/orina , Índice de Masa Corporal , Colágeno Tipo I/sangre , Colágeno Tipo I/normas , Ensayo de Inmunoadsorción Enzimática/normas , Femenino , Humanos , Persona de Mediana Edad , Osteocalcina/análisis , Osteocalcina/normas , Hormona Paratiroidea/análisis , Hormona Paratiroidea/normas , Fragmentos de Péptidos/sangre , Fragmentos de Péptidos/normas , Fragmentos de Péptidos/orina , Péptidos/sangre , Péptidos/normas , Premenopausia , Procolágeno/sangre , Procolágeno/normas , Procolágeno/orina , Valores de Referencia , Vitamina D/análogos & derivados , Vitamina D/análisis , Vitamina D/normas
9.
Scand J Clin Lab Invest ; 75(7): 549-61, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26305421

RESUMEN

Knowledge about the distributions of serum 25-hydroxyvitamin D (25(OH)D) concentrations in representative population samples is critical for the quantification of vitamin D deficiency as well as for setting dietary reference values and food-based strategies for its prevention. Such data for the European Union are of variable quality making it difficult to estimate the prevalence of vitamin D deficiency across member states. As a consequence of the widespread, method-related differences in measurements of serum 25(OH)D concentrations, the Vitamin D Standardization Program (VDSP) developed protocols for standardizing existing serum 25(OH)D data from national surveys around the world. The objective of the present work was to apply the VDSP protocols to existing serum 25(OH)D data from a Danish, a Norwegian, and a Finnish population-based health survey and from a Danish randomized controlled trial. A specifically-selected subset (n 100-150) of bio-banked serum samples from each of the studies were reanalyzed for 25(OH)D by LC-MS/MS and a calibration equation developed between old and new 25(OH)D data, and this equation was applied to the entire data-sets from each study. Compared to estimates based on the original serum 25(OH)D data, the percentage vitamin D deficiency (< 30 nmol/L) decreased by 21.5% in the Danish health survey but by only 1.4% in the Norwegian health survey; but was relatively unchanged (0% and 0.2%) in the Finish survey or Danish RCT, respectively, following VDSP standardization. In conclusion, standardization of serum 25(OH)D concentrations is absolutely necessary in order to compare serum 25(OH)D concentrations across different study populations, which is needed to quantify and prevent vitamin D deficiency.


Asunto(s)
Vitamina D/análogos & derivados , Adolescente , Adulto , Anciano , Niño , Preescolar , Cromatografía Liquida , Protocolos Clínicos , Dinamarca/epidemiología , Finlandia/epidemiología , Humanos , Modelos Logísticos , Persona de Mediana Edad , Valores de Referencia , Países Escandinavos y Nórdicos/epidemiología , Espectrometría de Masas en Tándem , Vitamina D/sangre , Vitamina D/normas , Deficiencia de Vitamina D/epidemiología
10.
Anal Chem ; 84(2): 956-62, 2012 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-22141317

RESUMEN

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health's Office of Dietary Supplements (NIH-ODS), has developed a Standard Reference Material (SRM) for the determination of 25-hydroxyvitamin D [25(OH)D] in serum. SRM 972 Vitamin D in Human Serum consists of four serum pools with different levels of vitamin D metabolites and has certified and reference values for 25(OH)D(2), 25(OH)D(3), and 3-epi-25(OH)D(3). Value assignment of this SRM was accomplished using a combination of three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). Chromatographic resolution of the 3-epimer of 25(OH)D(3) proved to be essential for accurate determination of the metabolites.


Asunto(s)
Vitamina D/análogos & derivados , Cromatografía Liquida , Humanos , Espectrometría de Masas , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vitamina D/análisis , Vitamina D/sangre , Vitamina D/normas
11.
Breast Cancer Res Treat ; 133(3): 1159-67, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22434523

RESUMEN

Aromatase inhibitor (AI)-related bone loss is associated with increased fracture rates. Vitamin D might play a role in minimising this effect. We hypothesised that 25-hydroxy-vitamin D concentrations [25(OH)D] after 3 months supplementation might relate to bone loss after 1 year on AI therapy. We conducted a prospective cohort study from January 2006 to December 2011 of a consecutive sample of women initiating AI for early breast cancer who were ineligible for bisphosphonate therapy and stayed on treatment for 1 year (N = 232). Serum 25(OH)D was measured at baseline and 3 months, and lumbar spine (LS) bone mineral density at baseline and 1 year. Subjects were supplemented with daily calcium (1 g) and vitamin D(3) (800 IU) and additional oral 16,000 IU every 2 weeks if baseline 25(OH)D was <30 ng/ml. Linear regression models were fitted to adjust for potential confounders. After 1 year on AI therapy, 232 participants experienced a significant 1.68 % [95 % CI 1.15-2.20 %] bone loss at LS (0.017 g/cm(2) [0.012-0.024], P < 0.0001). Higher 25(OH)D at 3 months protected against LS bone loss (-0.5 % per 10 ng/ml [95 % CI -0.7 to -0.3 %], adjusted P = 0.0001), and those who reached levels ≥40 ng/ml had reduced bone loss by 1.70 % [95 % CI 0.4-3.0 %; adjusted P = 0.005] compared to those with low 25(OH)D levels (<30 ng/ml). We conclude that improved vitamin D status using supplementation is associated with attenuation of AI-associated bone loss. For this population, the current Institute of Medicine target recommendation of 20 ng/ml might be too low to ensure good bone health.


Asunto(s)
Inhibidores de la Aromatasa/efectos adversos , Resorción Ósea/inducido químicamente , Resorción Ósea/prevención & control , Vitamina D/administración & dosificación , Vitamina D/sangre , Anciano , Densidad Ósea/efectos de los fármacos , Estudios de Cohortes , Suplementos Dietéticos , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Vitamina D/análogos & derivados , Vitamina D/normas
12.
Prev Med ; 55(3): 228-32, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22743294

RESUMEN

OBJECTIVE: To compare the public health implications of using unstandardized immunoassay measurements of serum 25-hydroxyvitamin D [25(OH)D] concentrations versus using measurements standardized by liquid chromatography tandem-mass spectrometry (LC-MS/MS) when assessing the prevalence of 25(OH)D insufficiency and deficiency in various subgroups of individuals. METHOD: We standardized immunoassay-based measurements of 25(OH)D with LC-MS/MS in a population-based sample of 5386 women aged 50-74 recruited in 2000-2002 in Germany. We used multivariate regression to assess 25(OH)D determinants and the association of vitamin D deficiency with health status. RESULTS: Prevalences of 25(OH)D levels <50 nmol/L (insufficiency) and <30 nmol/L (deficiency) decreased considerably by standardization. The decrease in vitamin D deficiency (from 64.4% to 17.9%) was particularly strong in March-May among women aged ≥ 65. Independent of season of blood draw and standardization, women ≥ 70 years, obese, or currently smoking had an increased risk of having 25(OH)D levels <30 nmol/L. CONCLUSION: The proportion of older women with vitamin D deficiency in Germany is much lower than previously reported, but prevalence of vitamin D insufficiency is high. Standardization of 25(OH)D values by immunoassay methods to LC-MS/MS equivalent values or direct measurement by LC-MS/MS is indispensable in drawing valid conclusions about the health implications of vitamin D deficiency or insufficiency.


Asunto(s)
Salud Pública , Deficiencia de Vitamina D/sangre , Vitamina D/análogos & derivados , Anciano , Envejecimiento/sangre , Cromatografía Liquida , Femenino , Alemania/epidemiología , Humanos , Persona de Mediana Edad , Prevalencia , Análisis de Regresión , Estudios Retrospectivos , Espectrometría de Masas en Tándem , Vitamina D/sangre , Vitamina D/normas , Deficiencia de Vitamina D/epidemiología
13.
J Pediatr Endocrinol Metab ; 34(12): 1515-1523, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34416104

RESUMEN

OBJECTIVES: Preterm infants are at increased risk for vitamin D deficiency (VDD). We aimed to assess the adequacy of standardized vitamin D supplementation protocol in very low birth weight (VLBW) infants. Additionally, vitamin D status of mother/infant couples and the associations between vitamin D status at birth and morbidities of the infants were investigated. METHODS: In this single-center, prospective cohort study blood samples were collected from 55 mothers just before delivery and from their infants at birth and on the 30th day of life (DOL) for 25 hydroxy vitamin D (25OHD) measurements. Vitamin D was initiated in dose of 160 IU/kg by parenteral nutrition on the first DOL and oral vitamin D supplementation (400 IU/day) was administered when enteral feedings reached 50% of total intake or on the 15th DOL. RESULTS: The median 25OHD levels of the infants were 16.12 (9.14-20.50) in cord blood and 36.32 (31.10-44.44) in venous blood on the 30th DOL (p<0.01). In 98% of the VLBW infants 25OHD reached sufficient levels on the 30th DOL. None of the mothers had sufficient vitamin D levels (25OHD >30 ng/mL). Maternal 25OHD levels were correlated with the 25OHD levels of the infants in cord blood (r=0.665, p<0.001). There was a significant difference in mean cord 25OHD levels between winter (13.65 ± 5.69 ng/mL) and summer seasons (19.58 ± 11.67 ng/mL) (p=0.021). No association was found between neonatal morbidity and vitamin D status. CONCLUSIONS: The results clearly show that by utilizing the current supplementation protocol, the majority of VLBW infants with deficient/insufficient serum 25OHD levels reached sufficient levels on the 30th DOL. Furthermore, vitamin D levels in mother/infant couples were found to be highly correlated.


Asunto(s)
Suplementos Dietéticos/normas , Recien Nacido Prematuro/crecimiento & desarrollo , Recién Nacido de muy Bajo Peso/crecimiento & desarrollo , Deficiencia de Vitamina D/dietoterapia , Vitamina D/análogos & derivados , Adulto , Femenino , Estudios de Seguimiento , Humanos , Recién Nacido , Masculino , Pronóstico , Estudios Prospectivos , Vitamina D/administración & dosificación , Vitamina D/normas , Adulto Joven
15.
PLoS One ; 15(9): e0239799, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32976513

RESUMEN

BACKGROUND: To investigate the association between serum 25-hydroxyvitamin D levels and its effect on adverse clinical outcomes, and parameters of immune function and mortality due to a SARS-CoV-2 infection. STUDY DESIGN: The hospital data of 235 patients infected with COVID-19 were analyzed. RESULTS: Based on CDC criteria, among our study patients, 74% had severe COVID-19 infection and 32.8% were vitamin D sufficient. After adjusting for confounding factors, there was a significant association between vitamin D sufficiency and reduction in clinical severity, inpatient mortality serum levels of C-reactive protein (CRP) and an increase in lymphocyte percentage. Only 9.7% of patients older than 40 years who were vitamin D sufficient succumbed to the infection compared to 20% who had a circulating level of 25(OH)D< 30 ng/ml. The significant reduction in serum CRP, an inflammatory marker, along with increased lymphocytes percentage suggest that vitamin D sufficiency also may help modulate the immune response possibly by reducing risk for cytokine storm in response to this viral infection. CONCLUSION: Therefore, it is recommended that improving vitamin D status in the general population and in particular hospitalized patients has a potential benefit in reducing the severity of morbidities and mortality associated with acquiring COVID-19.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Vitamina D/análogos & derivados , Adulto , Rutas de Resultados Adversos , Anciano , Anciano de 80 o más Años , Betacoronavirus , Proteína C-Reactiva/metabolismo , COVID-19 , Infecciones por Coronavirus/mortalidad , Infecciones por Coronavirus/prevención & control , Estudios Transversales , Femenino , Humanos , Inmunidad/efectos de los fármacos , Irán , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Pandemias/prevención & control , Neumonía Viral/mortalidad , Neumonía Viral/prevención & control , Pronóstico , SARS-CoV-2 , Resultado del Tratamiento , Vitamina D/sangre , Vitamina D/farmacología , Vitamina D/normas
16.
Am J Clin Pathol ; 151(2): 209-216, 2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30307462

RESUMEN

Objectives: We evaluated performance and measurement uncertainty of the newly released ARCHITECT 25-OH vitamin D 5P02 assay (Abbott Diagnostics, Abbott Park, IL). Methods: In total, 300 samples were used to compare the results from ELECSYS Vitamin D Total (Roche Diagnostics, Mannheim, Germany) and ADVIA Centaur Vitamin D Total (Siemens, Tarrytown, NY). To quantify the measurement uncertainty, 25 samples and four levels of standard reference material (SRM) were measured using isotope dilution-liquid chromatography-tandem mass spectrometry according to international guidelines. Results: The results of the ARCHITECT assay were equivalent to other immunoassays, but correlation coefficients were lower than the recommended criterion. SRM level 2 was considered adequate for uncertainty estimation, and the expanded measurement uncertainty of the ARCHITECT assay was 4.2%, which was superior to the other two assays. Conclusions: The restandardized ARCHITECT assay has acceptable performance in a clinical setting. However, there is still a need for further standardization of total vitamin D measurement among the automated immunoassays.


Asunto(s)
Inmunoensayo/métodos , Vitamina D/análogos & derivados , Cromatografía Liquida , Femenino , Humanos , Masculino , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem , Incertidumbre , Vitamina D/sangre , Vitamina D/normas
17.
Clin Chim Acta ; 497: 82-87, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31330127

RESUMEN

The current review provides an overview on the development of 25(OH)D measurement standardization tools over the last three decades and clarifies whether there is a role as a serum biomarker for vitamin D in neurological diseases. In the past, a lack of internationally recognized 25(OH)D reference measurement procedures and reference standard materials led to unstandardized serum total 25(OH)D results among research and clinical care laboratories. The vitamin D Standardization Program (VDSP) has been introduced in 2010 to address this problem, however, vitamin D External Quality Assessment Scheme (DEQAS) reports still show substantial sample- to- sample variability. Further, immunoassays, which are mainly used in clinical care laboratories, display analytical issues, including matrix-effects interferences, which cannot be overcome by the standardization process. Hence, liquid chromatography-tandem mass spectrometry (LC/MS-MS) methods should be used to measure 25(OH)D. Low vitamin D serum levels have been found in patients affected by Alzheimer's disease and Parkinson's disease, suggesting a role for vitamin D as a serum biomarker in these diseases. However, few studies reported 25(OH)D standardized results, thus, no clear evidence on the potential role of 25(OH)D serum levels in these diseases exists.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Parkinson/sangre , Vitamina D/análogos & derivados , Enfermedad de Alzheimer/diagnóstico , Biomarcadores/sangre , Cromatografía Liquida , Humanos , Enfermedad de Parkinson/diagnóstico , Espectrometría de Masas en Tándem , Vitamina D/sangre , Vitamina D/normas
20.
J Steroid Biochem Mol Biol ; 177: 255-260, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28935550

RESUMEN

The Longitudinal Aging Study Amsterdam (LASA) is an ongoing prospective cohort study in a representative sample of Dutch older persons. In previous LASA studies, lower serum 25-hydroxyvitamin D (25(OH)D) values, as assessed by a competitive protein binding assay or radioimmunoassay, have been associated with decreased physical functioning, falls and fractures. Recently, serum 25(OHD) values in LASA were standardized using the Vitamin D Standardization Program (VDSP) protocol as part of the European ODIN project. In the current manuscript, the influence of standardizing serum 25(OH)D values will be discussed using the associations with physical functioning, falls and fractures as examples.


Asunto(s)
Accidentes por Caídas , Envejecimiento/sangre , Fracturas Óseas/sangre , Rendimiento Físico Funcional , Vitamina D/análogos & derivados , Anciano , Anciano de 80 o más Años , Envejecimiento/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Estándares de Referencia , Vitamina D/sangre , Vitamina D/normas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda