Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
BMC Med Imaging ; 23(1): 51, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-37038130

RESUMO

BACKGROUND: Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices' image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. METHODS: Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) were analyzed for eight anatomical landmarks and evaluated by three evaluators. RESULTS: With the exception of protocol with 90 kVp 100 mAs, all other protocols used are competent to image the finest structures. With a moderate effective dose (86.5 µSv), protocol with 90 kV 450 mAs was chosen the best protocol used in this study. A significant correlation between CNR and clinical image quality of the protocols was observed in linear regression model. Using the optimized imaging parameters, we were able to distinguish even the most delicate middle ear structures in 2D images and produce accurate 3D reconstructions. CONCLUSIONS: In this ex vivo experiment, the new Planmed XFI® full body CBCT device produced excellent 2D resolution and easily created 3D reconstructions in middle ear imaging with moderate effective doses. This device would be suitable for middle ear diagnostics and for e.g., preoperative planning. Furthermore, the results of this study can be used to optimize the effective dose by selecting appropriate exposure parameters depending on the diagnostic task.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X/métodos , Orelha Média/diagnóstico por imagem
2.
Ear Hear ; 43(1): 220-233, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34260435

RESUMO

OBJECTIVES: Early hearing aid (HA) fitting and cochlear implants (CIs) aim to reduce the effects of hearing loss (HL) on spoken language development. The goals of this study were (1) to examine spoken language skills of children with bilateral HAs and children with bilateral CIs; (2) to compare their language skills to the age-norms of peers with normal hearing (NH); and (3) to investigate factors associated with spoken language outcomes. DESIGN: Spoken language results of 56 Finnish children with HL were obtained from a nationwide prospective multicenter study. Children with HL comprised two groups: children with mild-to-severe HL who used bilateral HAs (BiHA group, n = 28) and children with profound HL who used bilateral CIs (BiCI group, n = 28). Children's spoken language comprehension, expressive and receptive vocabulary, and phonological skills were compared with normative values of children with NH at the age of three years. Odds ratio (OR) was calculated to compare proportions of children below age-norms in BiHA and BiCI groups. Factors associated with spoken language outcomes were modeled with analysis of covariance. RESULTS: At the age of 3 years, 50%-96% of children with HL performed 1 SD or more below the mean of the normative sample of age-peers with NH in spoken language skills, depending on the language domain. Receptive vocabulary and phonological skills were the most vulnerable language domains. In receptive vocabulary, 82% of the children in the BiHA group and 50% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 4.4 times more likely to have poorer receptive vocabulary than the BiCI group. In phonological skills, 96% of children in the BiHA group and 60% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 18.0 times more likely to have poorer phonological skills than the BiCI group. The analysis of covariance models showed that unaided pure-tone average, PTA0.5-4 kHz, had a significant effect on spoken language comprehension in the BiHA group. For the BiCI group, age at HL diagnosis and age at CI activation had a significant effect on expressive vocabulary. High maternal level of education had a significant effect on language comprehension and expressive vocabulary and female gender on phonological skills. CONCLUSIONS: At the age of 3 years, especially receptive vocabulary and phonological skills caused difficulties for children with HL showing also considerable individual variation. Children with bilateral HAs seemed to be more likely to have poorer receptive vocabulary and phonological skills than children with bilateral CIs. A variety of factors was associated with outcomes in both groups. Close monitoring of spoken language skills of children with HL is important for ensuring similar opportunities for all children with HL and timely intervention, when needed.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Auxiliares de Audição , Perda Auditiva , Criança , Pré-Escolar , Implante Coclear/métodos , Surdez/cirurgia , Feminino , Humanos , Desenvolvimento da Linguagem , Masculino , Estudos Prospectivos , Vocabulário
3.
Acta Paediatr ; 111(8): 1585-1593, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35500132

RESUMO

AIM: Bacterial meningitis (BM) is a common cause of hearing loss in childhood. Our aim was to investigate bacterial aetiology, hearing impairment and outcome in childhood BM with vs. without otitis media (OM) in Angola. METHODS: Hearing was tested by auditory brainstem response in 391 (76%) children with confirmed BM. The bacteria identified from the ear discharge were compared to those from cerebrospinal fluid (CSF). The hearing findings were compared among children with vs. without OM on days 1 and 7 of hospitalization, and at follow-ups of 1, 3 and 6 month(s). RESULTS: No correlation was found in bacteriology between the ear discharge and CSF. On day 7 in hospital, hearing impairment (>40 dB) was common, regardless of whether concomitant OM or not (in 27% vs. 30%, respectively). Any hearing deficit on day 7 was associated with a higher risk of complicated or fatal clinical course (OR 2.76, CI95% 1.43-5.29, p = 0.002). CONCLUSION: No significant difference prevailed in hearing thresholds between children with or without OM in hospital on day 7 or at later follow-ups. Any hearing impairment during hospital stay associated with a higher risk for complicated clinical course or death.


Assuntos
Perda Auditiva , Meningites Bacterianas , Otite Média , Criança , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/etiologia , Testes Auditivos/efeitos adversos , Humanos , Meningites Bacterianas/complicações , Otite Média/complicações
4.
Int J Audiol ; 60(3): 210-219, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32964762

RESUMO

OBJECTIVE: Speech-in-noise tests are widely used in hearing diagnostics but typically without reverberation, although reverberation is an inextricable part of everyday listening conditions. To support the development of more real-life-like test paradigms, the objective of this study was to explore how spatially reproduced reverberation affects speech recognition thresholds in normal-hearing and hearing-impaired listeners. DESIGN: Thresholds were measured with a Finnish speech-in-noise test without reverberation and with two test conditions with reverberation times of ∼0.9 and 1.8 s. Reverberant conditions were produced with a multichannel auralisation technique not used before in this context. STUDY SAMPLE: Thirty-four normal-hearing and 14 hearing-impaired listeners participated in this study. Five people were tested with and without hearing aids. RESULTS: No significant differences between test conditions were found for the normal-hearing listeners. Results for the hearing-impaired listeners indicated better performance for the 0.9 s reverberation time compared to the reference and the 1.8 s conditions. Benefit from hearing aid use varied between individuals; for one person, an advantage was observed only with reverberation. CONCLUSIONS: Auralisations may offer information on speech recognition performance that is not obtained with a test without reverberation. However, more complex stimuli and/or higher signal-to-noise ratios should be used in the future.


Assuntos
Auxiliares de Audição , Percepção da Fala , Audição , Humanos , Ruído/efeitos adversos , Fala
5.
Int J Audiol ; 59(10): 753-762, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32338546

RESUMO

Objectives: To assess are there learning-related improvements in the speech reception thresholds (SRTs) for the Finnish matrix sentence test (FMST) and the Finnish digit triplet test (FDTT) in repeated use over 12 months.Design: Test sessions were scheduled at 0, 1, 3, 6 and 12 months, and each session included five FMST measurements and four FDTT measurements. The within-session and inter-session improvements in SRTs were analysed with a linear mixed model.Study sample: Fifteen young normal-hearing participants.Results: Statistically significant mean improvements of 2.0 dB SNR and 1.2 dB SNR were detected for the FMST and the FDTT, respectively, over the 12-month follow-up period. For the FMST, majority of the improvement occurred during the first two test sessions. For the FDTT, statistically significant differences were detected only in comparison to the first test session and to the first test measurement of every session over the 12-month follow-up.Conclusions: Repeated use of the FMST led to significant learning-related improvements, but the improvements appeared to plateau by the third test session. For the FDTT, the overall improvements were smaller, but a significant within-session difference between the first and consecutive FDTT measurements persisted throughout the test sessions.


Assuntos
Ruído , Percepção da Fala , Finlândia , Humanos , Reprodutibilidade dos Testes , Teste do Limiar de Recepção da Fala
6.
Curr Allergy Asthma Rep ; 16(10): 72, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27613655

RESUMO

Acute otitis media is a common infection in children. Most acute otitis media episodes can be treated at an outpatient setting with antimicrobials, or only expectant observation. Hospital treatment with parenteral medication, and myringotomy or tympanostomy, may be needed to treat those with severe, prolonged symptoms, or with complications. The most common intratemporal complication of acute otitis media is acute mastoiditis. If a child with acute mastoiditis does not respond to this treatment, or if complications develop, further examinations and other surgical procedures, including mastoidectomy, are considered. Since the treatment of complicated acute otitis media and complicated acute mastoiditis differs, it is important to differentiate these two conditions. This article focuses on the differential diagnostics of acute otitis media and acute mastoiditis in children.


Assuntos
Antibacterianos/uso terapêutico , Mastoidite/diagnóstico , Ventilação da Orelha Média/métodos , Otite Média/diagnóstico , Doença Aguda , Criança , Criança Hospitalizada , Pré-Escolar , Humanos , Otite Média/complicações
7.
J Acoust Soc Am ; 139(5): 2280, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250123

RESUMO

Tinnitus is associated with changes in neural activity. How such alterations impact the localization ability of subjects with tinnitus remains largely unexplored. In this study, subjects with self-reported unilateral tinnitus were compared to subjects with matching hearing loss at high frequencies and to normal-hearing subjects in horizontal and vertical plane localization tasks. Subjects were asked to localize a pink noise source either alone or over background noise. Results showed some degree of difference between subjects with tinnitus and subjects with normal hearing in horizontal plane localization, which was exacerbated by background noise. However, this difference could be explained by different hearing sensitivities between groups. In vertical plane localization there was no difference between groups in the binaural listening condition, but in monaural listening the tinnitus group localized significantly worse with the tinnitus ear. This effect remained when accounting for differences in hearing sensitivity. It is concluded that tinnitus may degrade auditory localization ability, but this effect is for the most part due to the associated levels of hearing loss. More detailed studies are needed to fully disentangle the effects of hearing loss and tinnitus.


Assuntos
Perda Auditiva/psicologia , Localização de Som , Zumbido/psicologia , Estimulação Acústica , Adulto , Audiometria , Limiar Auditivo , Estudos de Casos e Controles , Feminino , Audição , Perda Auditiva/diagnóstico , Perda Auditiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Mascaramento Perceptivo , Detecção de Sinal Psicológico , Zumbido/diagnóstico , Zumbido/fisiopatologia , Adulto Jovem
8.
Ear Hear ; 36(3): e76-85, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25437140

RESUMO

OBJECTIVES: The ability of a treatment method to interfere with tinnitus-related neural activity patterns, such as cortical gamma rhythms, has been suggested to indicate its potential in relieving tinnitus. Therapeutic modulation of gamma-band oscillations with vagus nerve stimulation has been recently reported in epileptic patients. The aim of this study was to investigate the effects of transcutaneous vagus nerve stimulation (tVNS) on neural oscillatory patterns. DESIGN: We calculated the power spectral density and synchrony of magnetoencephalography recordings during auditory stimulation in seven tinnitus patients and eight normal-hearing control subjects. Comparisons between subject groups were performed to reveal electrophysiological markers of tinnitus. tVNS-specific effects within each group were studied by comparing recording blocks with and without tVNS. We also investigated the correlation of each measure with individual ratings of tinnitus distress, as measured by the tinnitus handicap inventory questionnaire. RESULTS: Tinnitus patients differed from controls in the baseline condition (no tVNS applied), measured by both cortical oscillatory power and synchronization, particularly at beta and gamma frequencies. Importantly, we found tVNS-induced changes in synchrony, correlating strongly with tinnitus handicap inventory scores, at whole-head beta-band (r = -0.857, p = 0.007), whole-head gamma-band (r = -0.952, p = 0.0003), and frontal gamma-band (r = -0.952, p = 0.0003). CONCLUSIONS: We conclude that tVNS was successful in modulating tinnitus-related beta- and gamma-band activity and thus could have potential as a treatment method for tinnitus.


Assuntos
Ritmo beta/fisiologia , Sincronização Cortical/fisiologia , Ritmo Gama/fisiologia , Zumbido/terapia , Estimulação do Nervo Vago/métodos , Estimulação Acústica , Adulto , Feminino , Humanos , Magnetoencefalografia , Masculino , Pessoa de Meia-Idade , Estresse Psicológico/psicologia , Inquéritos e Questionários , Zumbido/fisiopatologia , Zumbido/psicologia , Estimulação Elétrica Nervosa Transcutânea , Adulto Jovem
9.
Int J Audiol ; 54 Suppl 2: 80-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26364512

RESUMO

OBJECTIVES: The first Finnish sentence-based speech test in noise--the Finnish matrix sentence test--was recently developed. The aim of this study was to determine the characteristics of the new test with respect to test-retest reliability, speech recognition curve, and international comparability in Finnish cochlear implant (CI) recipients. DESIGN: The speech reception thresholds (SRT) were measured by means of an adaptive test procedure and compared with the results of the traditional Finnish word test. Additional measurements for concurrent slope and SRT estimation were conducted to determine the speech recognition curve and to check the test-retest reliability. STUDY SAMPLE: The measurements were performed on 78 Finnish CI recipients. In a subset of 25 patients, additional measurements for test-retest reliability and slope determination were performed. RESULTS: The mean SRT was -3.5 ± 1.7 dB SNR, with only a weak correlation with the Finnish word test. Test-retest reliability was within ± 1 dB and the mean slope of the speech recognition curve was 14.6 ± 3.6 %/dB. The rehabilitation results were similar to the results published for the German matrix test. CONCLUSIONS: The Finnish matrix test was found to be suitable and efficient in CI recipients with similar characteristics as the German matrix test.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Multilinguismo , Pessoas com Deficiência Auditiva/reabilitação , Percepção da Fala , Teste do Limiar de Recepção da Fala/métodos , Estimulação Acústica , Adulto , Idoso , Limiar Auditivo , Compreensão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/psicologia , Valor Preditivo dos Testes , Psicoacústica , Reconhecimento Psicológico , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inteligibilidade da Fala
10.
Duodecim ; 130(8): 810-8, 2014.
Artigo em Finlandês | MEDLINE | ID: mdl-24822331

RESUMO

Tympanic membrane perforation may be caused by, e.g., trauma or acute or chronic middle ear infection. Perforation causes conductive hearing loss. Since it predisposes to infections, it is important to keep the ear dry. In most cases traumatic perforations heal spontaneously. Perforations caused by acute middle ear infections are treated with antibiotics. Chronic perforation due to chronic middle ear infection or cholesteatoma will usually not heal without surgery. Most perforation cases can be taken care of in primary care. ENT consultation is needed when alarming signs, such as continuous pain, vertigo or facial paralysis exist, or if the perforation persists.


Assuntos
Perfuração da Membrana Timpânica/complicações , Perfuração da Membrana Timpânica/terapia , Antibacterianos/uso terapêutico , Perda Auditiva Condutiva/etiologia , Humanos , Atenção Primária à Saúde , Encaminhamento e Consulta , Perfuração da Membrana Timpânica/etiologia
11.
Int J Bioprint ; 9(4): 727, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37323487

RESUMO

Despite advances in prosthesis materials, operating microscopes and surgical techniques during the last 50 years, long-lasting hearing improvement remains a challenge in ossicular chain reconstruction. Failures in the reconstruction are mainly due to inadequate length or shape of the prosthesis, or defects in the surgical procedure. 3D-printed middle ear prosthesis might offer a solution to individualize treatment and obtain better results. The aim of the study was to study the possibilities and limitations of 3D-printed middle ear prostheses. Design of the 3D-printed prosthesis was inspired by a commercial titanium partial ossicular replacement prosthesis. 3D models of different lengths (1.5-3.0 mm) were created with Solidworks 2019-2021 software. The prostheses were 3D-printed with vat photopolymerization using liquid photopolymer Clear V4. Accuracy and reproducibility of 3D printing were evaluated with micro-CT imaging. The acoustical performance of the prostheses was determined in cadaver temporal bones with laser Doppler vibrometry. In this paper, we present an outline of individualized middle ear prosthesis manufacturing. 3D printing accuracy was excellent when comparing dimensions of the 3D-printed prostheses and their 3D models. Reproducibility of 3D printing was good if the diameter of the prosthesis shaft was 0.6 mm. 3D-printed partial ossicular replacement prostheses were easy to manipulate during surgery even though they were a bit stiffer and less flexible than conventional titanium prostheses. Their acoustical performance was similar to that of a commercial titanium partial ossicular replacement prosthesis. It is possible to 3D print functional individualized middle ear prostheses made of liquid photopolymer with good accuracy and reproducibility. These prostheses are currently suitable for otosurgical training. Further research is needed to explore their usability in a clinical setting. In the future, 3D printing of individualized middle ear prostheses may provide better audiological outcomes for patients.

12.
Life Sci Alliance ; 5(2)2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34815294

RESUMO

Failure in the structural maintenance of the hair cell stereocilia bundle and ribbon synapse causes hearing loss. Here, we have studied how ER stress elicits hair cell pathology, using mouse models with inactivation of Manf (mesencephalic astrocyte-derived neurotrophic factor), encoding an ER-homeostasis-promoting protein. From hearing onset, Manf deficiency caused disarray of the outer hair cell stereocilia bundle and reduced cochlear sound amplification capability throughout the tonotopic axis. In high-frequency outer hair cells, the pathology ended in molecular changes in the stereocilia taper region and in strong stereocilia fusion. In high-frequency inner hair cells, Manf deficiency degraded ribbon synapses. The altered phenotype strongly depended on the mouse genetic background. Altogether, the failure in the ER homeostasis maintenance induced early-onset stereociliopathy and synaptopathy and accelerated the effect of genetic causes driving age-related hearing loss. Correspondingly, MANF mutation in a human patient induced severe sensorineural hearing loss from a young age onward. Thus, we present MANF as a novel protein and ER stress as a mechanism that regulate auditory hair cell maintenance in both mice and humans.


Assuntos
Cóclea/metabolismo , Células Ciliadas Auditivas Internas/metabolismo , Células Ciliadas Auditivas Externas/metabolismo , Fatores de Crescimento Neural/genética , Estereocílios/metabolismo , Sinapses/metabolismo , Suscetibilidade a Doenças , Homeostase , Fatores de Crescimento Neural/metabolismo
13.
Prog Brain Res ; 262: 93-113, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33931196

RESUMO

Characterizations of the tinnitus sound percept are always based on a subjective description by the person affected. Since the experimenter cannot have access to the tinnitus percept, it is not possible to verify whether individuals use the adjectives describing the sound in the expected way, i.e., whether a label given to the tinnitus percept corresponds to the label that the experimenter or another individual would give to the same sound percept. However, if it is assumed that tinnitus patients can reliably describe their own tinnitus, then they should also be able to reliably describe tinnitus-like sounds, presented acoustically. In this study, 26 tinnitus patients used a tablet computer to rate 18 pre-defined adjectives on their level of descriptiveness for their own tinnitus percept as well as 17 tinnitus-like sounds presented via headphones. The main interest of the current study was to calculate intraclass correlation (ICC) and Krippendorff's alpha coefficients for the rating profiles of the acoustically-presented sounds, in order to quantify how well the individuals agreed on the ratings of known sounds, i.e., whether the adjectives would receive similar ratings from all participants for a specific tinnitus-like sound. The results show that the level of agreement was low for all adjectives and sounds, meaning that the different individuals did not use the adjectives in a consistent manner. The conclusion is that subjective tinnitus descriptions should be interpreted with great caution, and that the inherent variability involved in the characterization of sounds by naïve listeners can contribute to the observed heterogeneity in tinnitus symptoms and treatment outcomes.


Assuntos
Zumbido , Humanos , Semântica , Som , Zumbido/complicações , Resultado do Tratamento
14.
J Otol ; 16(3): 138-143, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34220982

RESUMO

The objective was to evaluate the pure-tone audiogram-based screening protocols in VS diagnostics. We retrospectively analyzed presenting symptoms, pure tone audiometry and MRI finding from 246 VS patients and 442 controls were collected to test screening protocols (AAO-HNS, AMCLASS-A/B, Charing Cross, Cueva, DOH, Nashville, Oxford, Rule3000, Schlauch, Seattle, Sunderland) for sensitivity and specificity. Results were pooled with data from five other studies, and analysis of sensitivity, specificity and positive likelihood ratio (LR+) for each protocol was performed. Our results show that protocols with significantly higher sensitivity (AMCLASS-A/B, Nashville) show also significantly lowest specificity, and tend to have low association (positive likelihood ratio, LR+) to the VS. The highest LR+ was found for protocols AAO-HNS, Rule3000 and Seattle. In conclusions, knowing their properties, screening protocols are simple decision-making tools in VS diagnostic. To use the advantage of the highest sensitivity, protocols AMCLASS-A + B or Nashville can be of choice. For more reasonable approach, applying the protocols with high LR+ (AAO-HNS, Rule3000, Seattle) may reduce the overall number of MRI scans at expense of only few primarily undiagnosed VS.

15.
J Clin Med ; 10(11)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071662

RESUMO

Bilateral cochlear implantation is increasing worldwide. In adults, bilateral cochlear implants (BICI) are often performed sequentially with a time delay between the first (CI1) and the second (CI2) implant. The benefits of BICI have been reported for well over a decade. This study aimed at investigating these benefits for a consecutive sample of adult patients. Improvements in speech-in-noise recognition after CI2 were followed up longitudinally for 12 months with the internationally comparable Finnish matrix sentence test. The test scores were statistically significantly better for BICI than for either CI alone in all assessments during the 12-month period. At the end of the follow-up period, the bilateral benefit for co-located speech and noise was 1.4 dB over CI1 and 1.7 dB over CI2, and when the noise was moved from the front to 90 degrees on the side, spatial release from masking amounted to an improvement of 2.5 dB in signal-to-noise ratio. To assess subjective improvements in hearing and in quality of life, two questionnaires were used. Both questionnaires revealed statistically significant improvements due to CI2 and BICI. The association between speech recognition in noise and background factors (duration of hearing loss/deafness, time between implants) or subjective improvements was markedly smaller than what has been previously reported on sequential BICI in adults. Despite the relatively heterogeneous sample, BICI improved hearing and quality of life.

16.
J Otol ; 16(3): 150-157, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34220984

RESUMO

PURPOSE: An important outcome measure of patient care is the impact on the patient's health-related quality of life (HRQoL). Current ear-specific HRQoL instruments are designed for one diagnosis and emphasize different subdivisions such as symptoms, hearing problems, psychosocial impact, and the need for care. The optimal length of the recall period has not been studied. For these reasons, a new survey is needed that would cover most chronic ear diseases. METHODS: A preliminary 24-item survey (EOS-24) was created. Untreated adult patients (included n = 186) with one of seven different chronic otologic conditions from all university hospitals in Finland were recruited to respond to EOS-24 and the 15D general HRQoL instrument. The recruiting otologists evaluated the severity of the disease and the disability caused by it. A control group was recruited. Based on the patients' responses in different diagnosis groups, the items were reduced according to pre-defined criteria. The resulting survey was validated using a thorough statistical analysis. RESULTS: The relevance and necessity of the original 24 items were thoroughly investigated, leading to the exclusion of 8 items and the modification of 1. The remaining 16 items were well-balanced between subdivisions and were useful in all seven diagnosis groups, thus constituting the final instrument, EOS-16. The most suitable recall period was three months. CONCLUSIONS: EOS-16 has been created according to the HRQoL survey guidelines with a versatile nationwide patient population. The survey has been validated and can be used for a wide range of chronic ear diseases as a HRQoL instrument.

17.
Cochlear Implants Int ; 21(3): 153-159, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32160829

RESUMO

Objectives: To investigate the effect of fixed and adaptive microphone directionality on speech reception threshold (SRT) in noise when compared to omnidirectional mode in unilateral cochlear-implant (CI) use for three different CI systems.Methods: Twenty-four CI recipients with bilateral severe-to-profound hearing loss participated in the study. Eight recipients of each CI system were enrolled, and their SRT in noise was measured when the speech and noise signals were co-located in the front to serve as a baseline. The acute effect of different microphone directionalities on SRT in noise was measured with the noise emanating at 90° in the horizontal plane from the side of the CI sound processor (S0NCI).Results: When compared to the baseline condition, the individual data revealed fairly similar patterns within each CI system. In the S0NCI condition, the average improvement in SRT in noise for fixed and adaptive directionalities over the omnidirectional mode was statistically significant and ranged from 1.2 to 6.0 dB SNR and from 3.7 to 12.7 dB SNR depending on the CI system, respectively.Discussion: Directional microphones significantly improve SRT in noise for all three CI systems. However, relatively large differences were observed in the directional microphone efficacy between CI systems.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Surdez/psicologia , Desenho de Prótese/psicologia , Percepção da Fala/fisiologia , Adulto , Surdez/cirurgia , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Ruído , Período Pós-Operatório , Teste do Limiar de Recepção da Fala
18.
Audiol Res ; 9(1): 222, 2019 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31275536

RESUMO

Tinnitus is an auditory phantom sensation which can be a devastating condition for the affected person causing annoyance and discomfort. It may be associated with psychiatric conditions. Patients with highly annoying tinnitus and different comorbidities may have a higher risk of expressing suicidal behaviour and ideation. We aimed to review available reports on the prevalence of suicide and suicidal behaviour with tinnitus patients in order to collate current concepts and to identify possible alarming signs and risk factors. A comprehensive search for appropriate studies listed in PubMed, Ovid and Cochrane databases was conducted using appropriate keyword combinations. We identified 22 publications including original articles, case reports and reviews of which 10 fit our stringent search criteria. Most importantly, from the present studies it appears not feasible to univocally conclude on the co-incidence of tinnitus and suicide. This is due to methodological differences in these approaches, complex interrelations between tinnitus and other psychiatric comorbidities and confounding factors such as the inclusion of patients suffering from post-traumatic stress disorder. More concerted actions involving different medical disciplines are needed to reflect the ethiological heterogeneity of tinnitus and suicide or suicidal behaviour to test for a relationship.

19.
Pediatr Infect Dis J ; 38(8): 791-797, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31220047

RESUMO

BACKGROUND: Otitis media (OM) is a common childhood infection that may result in bacterial meningitis (BM). However, OM-associated BM remains poorly characterized. We aimed to study the occurrence, clinical presentation and outcome of this type of childhood BM in Luanda, Angola. METHODS: Five hundred twelve children from our previous clinical BM trial, with the ear meticulously examined, were analyzed whether they had or not OM, and according to their age, ≤12 month old and >12 month old. Prospectively collected clinical data, laboratory test results and outcome for these groups were assessed. RESULTS: Sixty-two children (12%) had OM-associated BM, of whom 39 had otorrhea. Ear discharge was more common in older children (median age 45 months old vs. 12 months old; P < 0.001). Children with OM often showed an additional infectious focus (n = 20, 32% vs. n = 82, 18%; P = 0.016), were dehydrated (n = 16, 26% vs. n = 66, 15%; P = 0.04), and showed higher odds of complicated clinical course or death (odds ratios 2.27, 95% CI: 1.004-5.15, P = 0.049) compared with children without OM. The >12-month-old children with OM often arrived in poor clinical condition with coma and/or ptosis. Otorrhea was associated with HIV positivity. Infants with otorrhea frequently lived under poor socioeconomic conditions. CONCLUSIONS: Children with OM-associated BM were prone to many problems, such as being especially ill at presentation, undergoing a difficult clinical course and showing a higher risk of complicated or fatal outcome. HIV infection and malnutrition were common in children with otorrhea, which was also associated with low socioeconomic status.


Assuntos
Meningites Bacterianas/epidemiologia , Meningites Bacterianas/etiologia , Otite Média/complicações , Otite Média/epidemiologia , Adolescente , Angola/epidemiologia , Criança , Pré-Escolar , Feminino , Hospitalização , Humanos , Lactente , Masculino , Meningites Bacterianas/diagnóstico , Razão de Chances , Otite Média/diagnóstico , Avaliação de Resultados da Assistência ao Paciente , Pobreza , Vigilância em Saúde Pública , Fatores Socioeconômicos
20.
BMC Ear Nose Throat Disord ; 8: 4, 2008 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-18664264

RESUMO

BACKGROUND: To evaluate the long-term surgical outcome(s) in patients who have undergone canal-wall-down operation with mastoid and epitympanic obliteration using autologous cortical bone chips, bone pate and meatally-based musculoperiosteal flap technique. METHOD: Retrospective evaluation of seventy patients operated during 1986-1991 due to a cholesteatoma. An otomicroscopy was performed to evaluate the postoperative outer ear canal configuration with a modified Likert scale (1 - 4). The outer ear canal physical volume was assessed by tympanometry. The hearing outcome and a patient-filled questionnaire were also analyzed. RESULTS: The posterior wall results were 1.8 (+/- 0.9 SD) and the attic region 1.8 (+/- 0.9 SD) (ns., p > 0.05). These values show either no cavity formation or minor formation of a cavity, with a good functional result. The mean volume of the operated ear canal was 1.7 (+/- 0.5 SD) ml. The volume of the contralateral ear canal was 1.2 (+/- 0.3 SD) ml (*** p < 0.0001). A comparison of the current mean ABG to the preoperative mean ABG and to the ABG at one-year postoperatively, 5-years postoperatively or 10-years postoperatively showed no statistical significance (p > 0.05). CONCLUSION: ABG does not significantly change in the long-term. The configuration of the cavity tends to change, however, the obliteration material is stable in the long-term and clinically significant cavitation rarely occurs.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa