Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Phys Chem Chem Phys ; 20(14): 9436-9448, 2018 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-29565435

RESUMO

Direct force measurements involving amidine latex (AL) and sulfate latex (SL) particles in aqueous solutions containing multivalent ferrocyanide anions are presented. These measurements feature three different pairs of particles, namely SL-SL, AL-SL, and AL-AL. The force profiles are quantitatively interpreted in terms of the theory by Derjaguin, Landau, Verwey, and Overbeek (DLVO) that is combined with a short-ranged exponential attraction. In monovalent salt solutions, the AL particles are positively charged, while the SL particles are negatively charged. In solutions containing ferrocyanide, the charge of the AL particles is reversed as the concentration is increased. The longer-ranged component of all force profiles is fully compatible with DLVO theory, provided effects of charge regulation are included. At shorter distances, an additional exponential attraction must be introduced, whereby the respective decay length is about 2 nm for the AL-AL pair, and below 1 nm for the SL-SL pair. This non-DLVO force is intermediate for the asymmetric AL-SL pair. These additional forces are probably related to charge fluctuations, patch-charged interactions, or hydrophobic forces.

2.
Anal Chem ; 87(11): 5524-30, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25924027

RESUMO

In this study we examine the experimental use of the staggered herringbone mixer (SHM) for the signal enhancement of a microfluidic surface plasmon resonance imaging (SPRi) affinity-based biosensor. We define the signal enhancement (Emix) as the ratio of the time-dependent slope of the sensor response of a SHM-based microfluidic channel and that of an unmixed channel; Emix is directly proportional to changes in the sensor sensitivity and inversely proportional to changes in the sensor limit of detection (LOD). Measurements were carried out for three SHM designs under a wide range of volumetric flow rates for two analytes: high diffusivity ssDNA and low diffusivity Escherichia coli bacteria. The experimental data collected in this study was found to exhibit a good match to that predicted by the numerical methods discussed in part I of this study. We found that Emix is dependent on the SHM groove geometry, the Péclet number Pe, and the overall microchannel length L; these dependencies are discussed in detail. For realistic experimental conditions, the enhancement that the SHM can provide is in the range of 1 < Emix < 5 (0% < improvement < 400%).


Assuntos
Técnicas Biossensoriais/instrumentação , DNA de Cadeia Simples/análise , Escherichia coli/isolamento & purificação , Técnicas Analíticas Microfluídicas/instrumentação , Modelos Biológicos , Ressonância de Plasmônio de Superfície
3.
Opt Express ; 21(8): 10121-32, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23609717

RESUMO

A new concept of compact biochip for surface plasmon-enhanced fluorescence assays is reported. It takes advantage of the amplification of fluorescence signal through the coupling of fluorophore labels with confined and strongly enhanced field intensity of surface plasmons. In order to efficiently excite and collect the emitted fluorescence light via surface plasmons on a metallic sensor surface, (reverse) Kretschmann configuration is combined with diffractive optical elements embedded on the chip surface. These include a concentric relief grating for the imaging of highly directional surface plasmon-coupled emission to a detector. Additional linear grating is used for the generating of surface plasmons at the excitation wavelength on the sensor surface in order to increase the fluorescence excitation rate. The reported approach offers the increased intensity of fluorescence signal, reduced background, and compatibility with nanoimprint lithography for cost-effective preparation of sensor chip. The presented approach was implemented for biosensing in a model immunoassay experiment in which the limit of detection of 11 pM was achieved.


Assuntos
Imunoensaio/instrumentação , Análise Serial de Proteínas/instrumentação , Espectrometria de Fluorescência/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
4.
Opt Express ; 20(13): 14042-53, 2012 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-22714469

RESUMO

Surface plasmon-coupled emission (SPCE) from emitters in a close proximity to a plasmonic Bragg grating is investigated. In this study, the directional fluorescence emission mediated by Bragg-scattered surface plasmons and surface plasmons diffraction cross-coupled through a thin metallic film is observed by using the reverse Kretschmann configuration. We show that controlling of dispersion relation of these surface plasmon modes by tuning the refractive index at upper and lower interfaces of a dense sub-wavelength metallic grating enables selective reducing or increasing the intensity of the light emitted to certain directions. These observations may provide important leads for design of advanced plasmonic structures in applications areas of plasmon-enhanced fluorescence spectroscopy and nanoscale optical sources.


Assuntos
Modelos Teóricos , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
5.
J Nanosci Nanotechnol ; 11(3): 2528-32, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21449418

RESUMO

A spin-coating method was applied for the first time to prepare a colloid monolayer on the optical crossed gratings used as a template. Four polystyrene colloids of various nominal sizes and different surface charges were spin-coated on templates with periods matched to the particles size. Three types of coverage were described depending on the spin-coating parameters and particles type. The optimal coverage was obtained for all four particles sizes. A way of finding the right spin-coating parameters was proposed. The analysis of a coverage capability of polystyrene particles showed that neutral particles have the highest ability to order on the templates used. Large monolayered areas of ordered particles were used as a lithographic mask for generating a pattern of gold nanoparticles with a square symmetry. A few hundred square micrometers large, continuous and fully defect-free areas of gold nanoparticles were produced on the nearly entire surface of the templated substrates.


Assuntos
Ouro/química , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Nanotecnologia/instrumentação , Poliestirenos/química , Ressonância de Plasmônio de Superfície/instrumentação , Cristalização/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Tamanho da Partícula , Rotação
6.
Clin Chim Acta ; 334(1-2): 107-10, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12867280

RESUMO

INTRODUCTION: To compare cerebrospinal fluid (CSF) and serum orosomucoid (alpha-1-acid glycoprotein-AAG) concentrations in various subgroups of patients with multiple sclerosis (MS). MATERIALS AND METHODS: CSF and serum AAG concentrations, AAG quotient (i.e., CSF AAG/serum AAGx10(3)) and index were determined in a group of 59 patients with clinically definite or probable MS. Patients were subdivided according to the disease form, disease severity according to an expanded disability status scale (EDSS), its treatment, disease duration and sex. RESULTS: CSF AAG was increased in 52.5% of the patients and AAG quotient even in 64.4%. An increase in the CSF AAG concentration, as well as in AAG quotient and index, appear only after several years of disease duration, while no significant correlation with age has been found. This suggests that CSF AAG changes in MS represent a secondary, unspecific phenomenon and that this protein is not relevant for the aethiopathogenesis of the disease. Nevertheless, the finding of subnormal CSF AAG levels in some MS patients in remission (never observed in those in the attack) implies the possibility that CSF AAG may be used as a "state marker" in MS. Serum AAG levels were significantly lower in secondary progressive form and in severely disabled patients. This observation suggest that serum AAG values determination might have some prognostic significance. Further studies are, however, needed. Serum AAG should be investigated in parallel with other CSF and serum protein fractions in order to establish a pannel of examinations enabling multiple statistical analyses. This approach may lead to the finding of a "complex state marker" enabling thus to evaluate more precisely disease course in individual patients and to accept appropriate therapeutic measures.


Assuntos
Esclerose Múltipla/sangue , Esclerose Múltipla/líquido cefalorraquidiano , Orosomucoide/líquido cefalorraquidiano , Biomarcadores , Humanos , Padrões de Referência , Caracteres Sexuais
7.
Dis Markers ; 2014: 495402, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24895473

RESUMO

Beta2-Microglobulin ( ß 2-m) is a low molecular weight protein occurring in all body fluids. Its concentration increases in various pathologies. Increased values in cerebrospinal fluid (CSF) are ascribed to an activation of immune system. Using immunoturbidimetry, we examined concentrations of beta2-microglobulin in cerebrospinal fluid in a large group of 6274 patients with defined neurological diseases. Cell counts, total protein, albumin, glucose, lactic acid, immunoglobulins concentrations, and isofocusing (IEF) were also evaluated. We found substantial changes of CSF ß 2-m concentrations in purulent meningitis, leptomeningeal metastasis, viral meningitis/encephalitis, and neuroborreliosis, while in multiple sclerosis these changes were not significant. Intrathecal synthesis and immune activation were present in these clinical entities. A new normative study enables better understanding of beta2-microglobulin behavior in CSF.


Assuntos
Infecções por Borrelia/líquido cefalorraquidiano , Neoplasias Meníngeas/líquido cefalorraquidiano , Meningites Bacterianas/líquido cefalorraquidiano , Meningite Viral/líquido cefalorraquidiano , Esclerose Múltipla/líquido cefalorraquidiano , Microglobulina beta-2/líquido cefalorraquidiano , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/líquido cefalorraquidiano , Infecções por Borrelia/diagnóstico , Estudos de Casos e Controles , Criança , Pré-Escolar , Humanos , Neoplasias Meníngeas/diagnóstico , Neoplasias Meníngeas/secundário , Meningites Bacterianas/diagnóstico , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Adulto Jovem
8.
Biosens Bioelectron ; 54: 506-14, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24321884

RESUMO

The combination of microarray technologies with microfluidic sample delivery and real-time detection methods has the capability to simultaneously monitor 10-1000 s of biomolecular interactions in a single experiment. Despite the benefits that microfluidic systems provide, they typically operate in the laminar flow regime under mass transfer limitations, where large analyte depletion layers act as a resistance to analyte capture. By locally stirring the fluid and delivering fresh analyte to the capture spot, the use of passive mixing structures in a microarray environment can reduce the negative effects of these depletion layers and enhance the sensor performance. Despite their large potential, little attention has been given to the integration of these mixing structures in microarray sensing environments. In this study, we use passive mixing structures to enhance the mass transfer of analyte to a capture spot within a microfluidic flow cell. Using numerical methods, different structure shapes and heights were evaluated as means to increase local fluid velocities, and in turn, rates of mass transfer to a capture spot. These results were verified experimentally via the real-time detection of 20-mer ssDNA for an array of microspots. Both numerical and experimental results showed that a passive mixing structure situated directly over the capture spot can significantly enhance the binding rate of analyte to the sensing surface. Moreover, we show that these structures can be used to enhance mass transfer in experiments regarding an array of capture spots. The results of this study can be applied to any experimental system using microfluidic sample delivery methods for microarray detection techniques.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise em Microsséries/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , DNA de Cadeia Simples/análise , Difusão , Desenho de Equipamento
9.
Biosens Bioelectron ; 51: 150-7, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23954672

RESUMO

The non-specific binding of non-target species to functionalized surfaces of biosensors continues to be challenge for biosensing in real-world media. Three different low-fouling and functionalizable surface platforms were employed to study the effect of functionalization on fouling resistance from several types of undiluted media including blood plasma and food media. The surface platforms investigated in this work included two polymer brushes: hydroxy-functional poly(2-hydroxyethyl methacrylate) (pHEMA) and carboxy-functional poly(carboxybetaine acrylamide) (pCBAA), and a standard OEG-based carboxy-functional alkanethiolate self-assembled monolayer (AT-SAM). The wet and dry polymer brushes were analyzed by AFM, ellipsometry, FT-IRRAS, and surface plasmon resonance (SPR). The surfaces were functionalized by the covalent attachment of antibodies, streptavidin, and oligonucleotides and the binding and biorecognition characteristics of the coatings were compared. We found that functionalization did not substantially affect the ultra-low fouling properties of pCBAA (plasma fouling of ~20 ng/cm(2)), a finding in contrast with pHEMA that completely lost its resistance to fouling after the activation of hydroxyl groups. Blocking a functionalized AT-SAM covalently with BSA decreased fouling down to the level comparable to unblocked pCBAA. However, the biorecognition capability of blocked functionalized AT-SAM was poor in comparison with functionalized pCBAA. Limits of detection of Escherichia coli O157:H7 in undiluted milk were determined to be 6×10(4), 8×10(5), and 6×10(5) cells/ml for pCBAA, pHEMA, and AT-SAM-blocked, respectively. Effect of analyte size on biorecognition activity of functionalized coatings was investigated and it was shown that the best performance in terms of overall fouling resistance and biorecognition capability is provided by pCBAA.


Assuntos
Acrilamidas/química , Escherichia coli/isolamento & purificação , Leite/microbiologia , Poli-Hidroxietil Metacrilato/química , Polímeros/química , Ressonância de Plasmônio de Superfície/métodos , Adsorção , Animais , Limite de Detecção , Compostos de Sulfidrila/química , Propriedades de Superfície
10.
Lab Chip ; 13(7): 1413-21, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23407647

RESUMO

Affinity-based biosensing systems have become an important analytical tool for the detection and study of numerous biomolecules. The merging of these sensing technologies with microfluidic flow cells allows for faster detection times, increased sensitivities, and lower required sample volumes. In order to obtain a higher degree of performance from the sensor, it is important to know the effects of the flow cell geometry on the sensor sensitivity. In these sensors, the sensor sensitivity is related to the overall diffusive flux of analyte to the sensing surface; therefore increases in the analyte flux will be manifested as an increase in sensitivity, resulting in a lower limit of detection (LOD). Here we present a study pertaining to the effects of the flow cell height H on the analyte flux J, where for a common biosensor design we predict that the analyte flux will scale as J ≈ H(-2/3). We verify this scaling behavior via both numerical simulations as well as an experimental surface plasmon resonance (SPR) biosensor. We show the reduction of the flow cell height can have drastic effects on the sensor performance, where the LOD of our experimental system concerning the detection of ssDNA decreases by a factor of 4 when H is reduced from 47 µm to 7 µm. We utilize these results to discuss the applicability of this scaling behavior with respect to a generalized affinity-based biosensor.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Sequência de Bases , DNA de Cadeia Simples/análise , DNA de Cadeia Simples/genética , Limite de Detecção
11.
Biomed Res Int ; 2013: 745943, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23865063

RESUMO

Urgent examination of cerebrospinal fluid (CSF) provides immediate important information about the character of central nervous system (CNS) impairment. Although this examination includes energy parameters such as glucose and lactate concentrations, it does not commonly use Coefficient of Energy Balance (CEB). In this study, we focused on CEB because it enables more exact assessment of actual energy state in the CSF compartment than glucose and lactate alone. CEB informs about the actual functioning condition of present cells, and it does not require any other analysis or costs. Using Kruskal-Wallis ANOVA, we examined a large CSF sample (n = 8183) and we compared CEB values among groups with different cytological syndromes. We found a statistically significant difference of CEB between the group with granulocyte pleocytosis and the control group. These results indicate a high degree of anaerobic metabolism caused by the oxidative burst of neutrophils. Similarly, we found a statistically significant difference of CEB between the control group and groups with tumorous oligocytosis plus pleocytosis and monocyte pleocytosis. This difference can be attributed to the oxidative burst of macrophages. Our findings suggest that CEB combined with CSF cytology has a great importance for diagnosis, differential diagnosis, and early therapy of CNS diseases.


Assuntos
Doenças do Sistema Nervoso Central/diagnóstico , Doenças do Sistema Nervoso Central/metabolismo , Diagnóstico Precoce , Metabolismo Energético , Doenças do Sistema Nervoso Central/líquido cefalorraquidiano , Neoplasias do Sistema Nervoso Central/líquido cefalorraquidiano , Neoplasias do Sistema Nervoso Central/metabolismo , Diagnóstico Diferencial , Humanos , Fagócitos/metabolismo , Fagócitos/patologia , Valores de Referência , Explosão Respiratória
12.
Opt Lett ; 32(20): 2903-5, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17938647

RESUMO

We report a new approach to characterization of thin (bio)molecular films based on spectroscopy of Bragg-scattered surface plasmons (BSSPs) generated by diffraction-coupling of counterpropagating surface plasmons on a metal-coated diffraction grating. The BSSPs exhibit fields with different penetration depths into the medium adjacent to the metal and therefore exhibit unequal sensitivities to the presence of (bio)molecular films on the surface of the metal. Therefore, spectroscopy of BSSPs enables in situ observation of the formation of biomolecular films and determination of both their refractive index and thickness. We demonstrate this capacity of spectroscopy of BSSPs in a model experiment in which growth of protein layers on a gold surface is studied.


Assuntos
Biopolímeros/química , Membranas Artificiais , Refratometria/métodos , Análise Espectral/métodos , Ressonância de Plasmônio de Superfície/métodos , Luz , Espalhamento de Radiação
13.
Clin Chem Lab Med ; 41(3): 331-7, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12705343

RESUMO

A group of neurologists and clinical neurochemists representing twelve countries worked towards a consensus on laboratory techniques to improve the quality of analysis and interpretation of cerebrospinal fluid (CSF) proteins. Consensus was approached via a virtual Lotus Notes-based TeamRoom. This new approach respecting multicultural differences, common views, and minority opinions, is available in http://www.teamspace.net/ CSF, presenting the implicit, complementary version of this explicit, printed consensus. Three key recommendations were made: CSF and (appropriately diluted) serum samples should be analyzed together in one analytical run, i.e., with reference to the same calibration curve. Results are evaluated as CSF/serum quotients, taking into account the non-linear, hyperbolic relation between immunoglobulin (Ig)- and albumin-quotients rather than using the linear IgG index or IgG synthesis rate. Controls should include materials with values within the reference ranges (IgM: 0.5-1.5 mg/l; IgA: 1-3 mg/l; IgG: 10-30 mg/l and albumin: 100-300 mg/l). The physiological, methodological and clinical significance of CSF/serum quotients is reviewed. We confirmed the previous consensus on oligoclonal IgG, in particular the usefulness of the five typical interpretation patterns. The group compared current external and internal quality assurance schemes and encouraged all members to maintain national or local traditions. Values for acceptable imprecision in the CSF quality assurance are proposed.


Assuntos
Albuminas/líquido cefalorraquidiano , Proteínas do Líquido Cefalorraquidiano/análise , Imunoglobulina A/líquido cefalorraquidiano , Imunoglobulina G/líquido cefalorraquidiano , Imunoglobulina M/líquido cefalorraquidiano , Garantia da Qualidade dos Cuidados de Saúde , Química Clínica/normas , Química Clínica/estatística & dados numéricos , Técnicas de Laboratório Clínico , Redes de Comunicação de Computadores/organização & administração , Humanos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Focalização Isoelétrica , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa