Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38773853

RESUMO

Transfemoral transcatheter aortic valve replacement is the preferred primary access route whenever possible. Despite advancements in expertise and delivery system profiles, complications associated with the primary femoral access still significantly affect procedural morbidity and outcomes. The current standard for accurate main access planning involves proper preprocedural evaluation guided by computed tomography. Several baseline clinical and anatomical features serve as predictors for the risk of vascular injury occurring during or after transcatheter aortic valve replacement. In this paper, we aimed at reviewing the most up-to-date knowledge of the topic for a safe transfemoral access approach according to a paradigm we have called "PIGTAIL."

2.
Circ Res ; 131(3): 239-257, 2022 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-35770662

RESUMO

BACKGROUND: Conversion of cardiac stromal cells into myofibroblasts is typically associated with hypoxia conditions, metabolic insults, and/or inflammation, all of which are predisposing factors to cardiac fibrosis and heart failure. We hypothesized that this conversion could be also mediated by response of these cells to mechanical cues through activation of the Hippo transcriptional pathway. The objective of the present study was to assess the role of cellular/nuclear straining forces acting in myofibroblast differentiation of cardiac stromal cells under the control of YAP (yes-associated protein) transcription factor and to validate this finding using a pharmacological agent that interferes with the interactions of the YAP/TAZ (transcriptional coactivator with PDZ-binding motif) complex with their cognate transcription factors TEADs (TEA domain transcription factors), under high-strain and profibrotic stimulation. METHODS: We employed high content imaging, 2-dimensional/3-dimensional culture, atomic force microscopy mapping, and molecular methods to prove the role of cell/nuclear straining in YAP-dependent fibrotic programming in a mouse model of ischemia-dependent cardiac fibrosis and in human-derived primitive cardiac stromal cells. We also tested treatment of cells with Verteporfin, a drug known to prevent the association of the YAP/TAZ complex with their cognate transcription factors TEADs. RESULTS: Our experiments suggested that pharmacologically targeting the YAP-dependent pathway overrides the profibrotic activation of cardiac stromal cells by mechanical cues in vitro, and that this occurs even in the presence of profibrotic signaling mediated by TGF-ß1 (transforming growth factor beta-1). In vivo administration of Verteporfin in mice with permanent cardiac ischemia reduced significantly fibrosis and morphometric remodeling but did not improve cardiac performance. CONCLUSIONS: Our study indicates that preventing molecular translation of mechanical cues in cardiac stromal cells reduces the impact of cardiac maladaptive remodeling with a positive effect on fibrosis.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal , Fosfoproteínas , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Animais , Fibrose , Humanos , Camundongos , Fosfoproteínas/metabolismo , Transativadores/genética , Transativadores/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Ativação Transcricional , Verteporfina , Proteínas de Sinalização YAP
3.
J Card Surg ; 37(7): 1887-1893, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35249231

RESUMO

AIMS: In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. METHODS AND RESULTS: We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). CONCLUSIONS: In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda
4.
J Card Surg ; 36(6): 2095-2098, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33709408

RESUMO

Fully percutaneous transfemoral transcatheter aortic valve replacement (TF-TAVR) is currently the standard of the catheter-based treatment of severe aortic stenosis patients. Even though experience, lower delivery catheters profile and improved vascular closure devices performances have resulted in an overall reduction of both vascular and bleeding complications after TAVR, femoral pseudoaneurysm due to incomplete local hemostasis may occur, prolonging the in-hospital length of stay, causing discomfort to the patient and potentially evolving in serious consequences affecting the outcome. We report two successful percutaneous ultrasound-guided closure of both the main and secondary femoral access pseudoaneurysm.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
6.
J Card Surg ; 35(8): 2089-2092, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32652613

RESUMO

Multiple valve replacements are known to carry additional risk of morbidity and mortality in redo context. Currently, a transcatheter-based valve-in-valve approach could be useful in reducing potential serious consequences. On the other hand, this approach poses several technical challenges regarding the device and the procedural aspects. We present the case of a 78-year-old man who presented with symptoms of heart failure due to mitral and aortic bioprosthesis degenerations who was deemed to be at extremely high risk for a conventional redo surgery. A two-step transcatheter-based approach was planned and a transfemoral aortic valve-in-valve procedure was followed by a transapical mitral valve-in-valve implantation with a favorable early and long-term outcome.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Estenose da Valva Mitral/cirurgia , Equipe de Assistência ao Paciente , Reoperação , Volume Sistólico , Resultado do Tratamento
7.
J Card Surg ; 35(1): 158-162, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31730741

RESUMO

OBJECTIVES: Morbidity associated with coronary artery bypass grafts and embolization during aortic cannulation is strongly related to patient characteristics/comorbidities, arterial cannulation site used and the shape of arterial cannulae tips. The desired features of an arterial cannula should be to mitigate the morbid effects of these cannulas and to focus on achieving higher blood flows with lower cannula pressures (CPs). MATERIALS AND METHODS: To evaluate the in vivo performance of two aortic dispersion flow cannulas: the Optiflow (Sorin Group, Italy) and EZ Glide (Edwards Lifesciences). They were evaluated for CPs, pump-flow rates (FRs), and plasma-free hemoglobin (Hb) over a 12-month period. Data were collected in a prospective, randomized (1:1), nonblinded, monocentric study with a cohort of 30 patients (optiflow group N = 15; EZ Glide group N = 15). RESULTS: The optiflow cannula was found to have decreasing CPs as the pump FRs were increased (112.3 ± 10.9 vs 131.1 ± 11.4 mm Hg; P < .001). Results indicated no significant differences between groups for increases in plasma free Hb (P = .41) and total microembolic signals counts during the period of cardiac surgery (P = .63). CONCLUSIONS: Both optiflow and EZ Glide dispersion flow arterial cannulas performed well, but the optiflow cannula demonstrated an ability to increase pump FRs with lower arterial line and CPs than the EZ Glide cannula. This implies an ability to improve peripheral perfusion while reducing cannula shear stress and the risk of endothelial damage, thereby having the potential to reduce the risk of atherosclerotic plaque dislodgement.


Assuntos
Artérias , Cateterismo/métodos , Idoso , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Ponte de Artéria Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Card Surg ; 32(3): 193-195, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28198045

RESUMO

We describe a technique using an Edwards Intuity Elite rapid deployment bioprosthesis to construct a composite graft for an aortic root replacement.


Assuntos
Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Bioprótese , Implante de Prótese Vascular/métodos , Prótese Vascular , Idoso , Humanos , Masculino , Resultado do Tratamento
10.
J Heart Valve Dis ; 24(6): 669-678, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27997769

RESUMO

BACKGROUND: The study aim was to compare the outcome of transapical transcatheter aortic valve replacement (TaTAVR) and traditional aortic valve replacement (AVR) in redo from two real-world registries. METHODS: The 30-day and follow up outcome of 462 patients enrolled in two multicenter redo registries, treated with redo-AVR (RAVR; n = 292 patients) or TaTAVR (n = 170 patients), were analyzed according to VARC-2 criteria, stratified also by propensity-matching analysis. RESULTS: TaTAVR-patients were older and sicker than RAVR patients, and reported a higher all-cause 30-day mortality (p <0.01), a higher risk for all-cause mortality (p = 0.006) and cardiovascular mortality (p = 0.05) at follow up, but similar 30-day cardiovascular mortality (p = 0.12). Prolonged intubation (p <0.01) and Acute Kidney Injury Network (AKIN) 2/3 p = 0.02) prevailed in RAVR. TaTAVR patients reported a higher level of major/life-threatening/disabling bleeding (p <0.01) and 'early safety-events' (ES) (p = 0.04). Thirty-day acute myocardial infarction (AMI), stroke, and follow up freedom from acute heart failure (AHF), from stroke and from reinterventions were similar (p = NS). The NYHA class was better after RAVR (p <0.01). The intermediate-to-high risk (Logistic EuroSCORE RAVR 17.1 ± 8.5; TaTAVR 16.0 ± 17.0) propensity-matched population demonstrated comparable 30-day and follow up all-cause and cardiovascular mortality, ES, AMI, stroke, prolonged intubation, follow up freedom from AHF, from stroke and from reinterventions and NYHA class. TaTAVR still reported lower levels of AKIN 2/3 (2.2% versus 15.6%, p = 0.03) and shorter hospitalization (9.5 ± 3.4 days versus 12.0 ± 7.0 days, p = 0.03). CONCLUSIONS: Outcome differences between RAVR and TaTAVR in redo-scenarios reflect methodological differences and different baseline risk profiles. Propensity-matched patients showed a better renal outcome after TaTAVR. *Drs. Onorati and D'Onofrio contributed equally to this article and should both be considered as first authors.

12.
J Clin Med ; 13(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38592382

RESUMO

Background: Currently, transcatheter aortic valve implantation (TAVI) is the standard procedure recommended for patients over 75 years of age with symptomatic aortic valve stenosis. Percutaneous transfemoral (TF) access is the main route used to perform the procedure. Among periprocedural complications, access-related ones are the most frequent, potentially leading to prolonged in-hospital stays and transfusions. Methods: We performed a retrospective analysis of prospectively collected data on consecutive patients undergoing TF-TAVI with the latest generation balloon-expandable transcatheter valve between 2013 and 2022. Results: A total of 600 patients were analyzed, differentiating the population between ultrasound-guided and blind common femoral artery puncture. Valve Academic Research Consortium 3 (VARC-3)criteria were used to report at 30 days and follow-up. In our propensity-matched comparison of the two groups, we found a strong reduction in access-related complications in the echo-guided group, particularly in terms of reduction of major and minor bleedings. We also found a significant trend in reduction of local complications, such as pseudoaneurysms, hematomas, arterio-venous fistulas, dissection of the femoral or iliac arteries, and stenosis. Conclusions: Although there is a lack of consensus on the role of ultrasound-guided puncture, we found better outcomes for patients having an echo-guided puncture of the main access, particularly with regard to access-related complications, early mobilization, and early discharge home.

17.
G Ital Cardiol (Rome) ; 24(2): 122-124, 2023 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-36735310

RESUMO

We report the case of a 28-year-old Caucasian patient symptomatic for low-threshold angina. Coronary angiography ruled out significant coronary stenosis. He was diagnosed with familial hypercholesterolemia and severe aortic stenosis in a setting of bicuspid valve disease. Preoperative evaluation showed diffuse atheromatous disease and severe calcification of the ascending aorta. The patient was treated by endarterectomy of the ascending aorta, non-coronary sinus enlargement patch and aortic valve replacement. This case report emphasizes the role of aortic valve disease in patients with familial hypercholesterolemia and highlights the complexity of surgical management of this condition.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Calcinose , Hipercolesterolemia , Hiperlipoproteinemia Tipo II , Masculino , Humanos , Adulto , Doença da Válvula Aórtica Bicúspide/complicações , Hipercolesterolemia/complicações , Aorta Torácica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Hiperlipoproteinemia Tipo II/complicações
18.
Am J Cardiol ; 209: 173-180, 2023 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-37858597

RESUMO

Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most challenging subset of patients to manage and generally have a poor prognosis. Few and controversial data exist on the outcomes of these patients compared with normal flow-high gradient (NF-HG) AS after transcatheter aortic valve replacement (TAVR). We sought to characterize different transvalvular flow-gradient patterns and to examine their prognostic value after TAVR. We enrolled 1,208 patients with severe AS and categorized as follow: 976 patients NF-HG (mean aortic pressure gradient [MPG] ≥40 mm Hg), 107 paradoxical LF-LG (pLF-LG, MPG <40 mm Hg, LVEF ≥50%, stroke volume index <35 ml/m2), and 125 classical LF-LG (cLF-LG) (MPG <40 mm Hg, LVEF <50%, stroke volume index <35 ml/m2). When compared with NF-HG and pLF-LG, cLF-LG had a worse symptomatic status (New York Heart Association III to IV 86% vs 62% and 67%, p <0.001), a higher prevalence of eccentric hypertrophy and a higher level of LV global afterload reflected by a higher valvuloarterial impedance. Valvular function after TAVR was excellent over time in all patients. While 30-day mortality (p = 0.911) did not differ significantly among groups, cLF-LG had a lower 5-year survival rate (LF-LG 50% vs pLF-LG 62% and NF-HG 68%, p <0.05). cLF-LG was associated with a hazard ratio for mortality of 2.41 (95% confidence interval 1.65 to 3.52, p <0.001). In conclusion, TAVR is an effective procedure regardless of transvalvular flow-gradient patterns. However, special care should be given to characterized hemodynamic of AS, as patients with pLF-LG had similar survival rates than patients with NF-HG, whereas cLF-LG is associated with a twofold increased risk of mortality at 5-year follow-up.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
19.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37968032

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Assuntos
Fibrilação Atrial , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Constrição Patológica/etiologia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica , Sistema de Registros , Desenho de Prótese
20.
J Card Surg ; 27(6): 676-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23061405

RESUMO

The widely used peripheral vein site of cannulation (i.e., the femoral vein) cannot always be employed in the setting of re-redo procedures. We propose a safe and simple surgical technique for a femoral vein cannulation using the greater saphenous vein as the inflow tract for the venous drainage in the setting of redo cardiac surgery.


Assuntos
Cateterismo/métodos , Veia Femoral , Implante de Prótese de Valva Cardíaca , Veia Safena , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese/efeitos adversos , Reoperação , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Inferior
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa