Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Circ Cardiovasc Interv ; 17(10): e014042, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39351676

RESUMO

BACKGROUND: No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting. METHODS: In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha. RESULTS: Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; P=0.02 for noninferiority at a 0.025 significance level and P=0.55 for 2-sided superiority at a 0.05 significance level). CONCLUSIONS: Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Hemorragia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Desenho de Prótese , Sirolimo , Humanos , Masculino , Feminino , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Pessoa de Meia-Idade , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Terapia Antiplaquetária Dupla/efeitos adversos , Fatores de Risco , Medição de Risco , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Fatores de Tempo
2.
J Am Coll Cardiol ; 80(13): 1220-1237, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36137672

RESUMO

BACKGROUND: The optimal duration of antiplatelet therapy (APT) after coronary stenting in patients at high bleeding risk (HBR) presenting with an acute coronary syndrome remains unclear. OBJECTIVES: The objective of this study was to investigate the safety and efficacy of an abbreviated APT regimen after coronary stenting in an HBR population presenting with acute or recent myocardial infarction. METHODS: In the MASTER DAPT trial, 4,579 patients at HBR were randomized after 1 month of dual APT (DAPT) to abbreviated (DAPT stopped and 11 months single APT or 5 months in patients with oral anticoagulants) or nonabbreviated APT (DAPT for minimum 3 months) strategies. Randomization was stratified by acute or recent myocardial infarction at index procedure. Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes events (NACE); major adverse cardiac and cerebral events (MACCE); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: NACE and MACCE did not differ with abbreviated vs nonabbreviated APT regimens in patients with an acute or recent myocardial infarction (n = 1,780; HR: 0.83; 95% CI: 0.61-1.12 and HR: 0.86; 95% CI: 0.62-1.19, respectively) or without an acute or recent myocardial infarction (n = 2,799; HR: 1.03; 95% CI: 0.77-1.38 and HR: 1.13; 95% CI: 0.80-1.59; Pinteraction = 0.31 and 0.25, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding was significantly reduced in patients with or without an acute or recent myocardial infarction (HR: 0.65; 95% CI: 0.46-0.91 and HR: 0.71; 95% CI: 0.54-0.92; Pinteraction = 0.72) with abbreviated APT. CONCLUSIONS: A 1-month DAPT strategy in patients with HBR presenting with an acute or recent myocardial infarction results in similar NACE and MACCE rates and reduces bleedings compared with a nonabbreviated DAPT strategy. (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020).


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Anticoagulantes/uso terapêutico , Dimaprit/análogos & derivados , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Infarto do Miocárdio/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros , Stents , Resultado do Tratamento
3.
Anaesthesiol Intensive Ther ; 53(1): 37-54, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33788503

RESUMO

Aortic stenosis (AS) causes left ventricular outflow obstruction. Severe AS has major haemodynamic implications in critically ill patients, in whom increased cardiac output and oxygen delivery are often required. Transthoracic echocardiography (TTE) plays a key role in the AS severity grading. In this review, we will give an overview of how to use the simplified Bernoulli equation to convert the echo Doppler measured velocities (cm s-1) to AS peak and mean gra-dient (mm Hg) and how to calculate the aortic valve area (AVA), using the continuity equation, based on the principle of preservation of flow. TTE allows quantification of compensatory left ventricular (LV) hypertrophy, assessment of LV systolic function, and determination of LV diastolic function and LV loading. Subsequently, the obtained results from the TTE study need to be integrated to establish the AS severity grading. The pitfalls of echocardiographic AS severity assessment are explained, and how to deal with inconsistency between AVA and mean gradient. The contribution of transoesophageal echocardiography, low-dose dobutamine stress echo (in case of low-flow low-gradient AS), echocardiography strain imaging, cardiac magnetic resonance imaging, cardiac multidetector computed tomography and the relatively new concept of Flow Pressure Gradient Classification to the work-up for aortic stenosis is discussed. Finally, the treatment of AS is overviewed. Elective aortic valve replacement is indicated in patients with severe symptomatic AS. In the ICU, afterload reduction by vasodilator therapy and treatment of pulmonary and venous congestion by diuretics could be considered.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estado Terminal , Ecocardiografia Doppler , Humanos , Índice de Gravidade de Doença , Função Ventricular Esquerda
4.
Anaesthesiol Intensive Ther ; 53(1): 55-68, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33788504

RESUMO

Inadequate diastolic closure of the aortic valve causes aortic regurgitation (AR). Diastolic regurgitation towards the left ventricle (LV) causes LV volume overload, resulting in eccentric LV remodelling. Transthoracic echocardiography (TTE) is the first line examination in the work-up of AR. TTE allows quantification of left ventricular end-diastolic diameter and volume and left ventricular ejection fraction, which are key elements in the clinical decision making regarding the timing of valve surgery. The qualitative echocardiographic features contributing to the AR severity grading are discussed: fluttering of the anterior mitral valve leaflet, density and shape of the continuous wave Doppler signal of the AR jet, colour flow imaging of the AR jet width, and holodiastolic flow reversal in the descending thoracic aorta and abdominal aorta. Volumetric assessment of the AR is performed by measuring the velocity time integral of the left ventricular outflow tract (LVOT) and transmitral valve (MV) plane, and diameters of LVOT and MV. We explain how the regurgitant fraction and effective regurgitant orifice area (EROA) can be calculated. Alternatively, the proximal isovelocity surface area can be used to determine the EROA. We overview the utility of pressure half time and vena contracta width to assess AR severity. Further, we discuss the role of transoesophageal echocardiography, echocardiography speckle tracking strain imaging, cardiac magnetic resonance imaging and computed tomography of the thoracic aorta in the work-up of AR. Finally, we overview the criteria for valve surgery in AR.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estado Terminal , Ecocardiografia Doppler em Cores , Humanos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa