Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Blood Press Monit ; 27(1): 43-49, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34417374

RESUMO

OBJECTIVE: The aim of this study was to evaluate the left ventricular (LV) function by conventional two-dimensional speckle tracking echocardiography (2D STE) to detect subclinical LV systolic dysfunction in patients with dipper and nondipper hypertension. METHODS: One hundred consecutive patients with hypertension were included in our study. Clinical evaluation, baseline laboratory investigations, 24 ambulatory blood pressure monitoring 2D echocardiographic examination and 2D STE were performed for all patients. Patients were classified as dippers and nondippers according to their nighttime MAP (mean arterial blood pressure) reduction rate of ≥10 or <10%, respectively. RESULTS: Of 100 patients, 71% were nondippers while 29% were dippers. Nondippers had a significantly lower global longitudinal strain (LS) value (-22.45 ± 3.26 vs. -18.2 ± 3.3, P < 0.001), global circumferential strain (CS) value (-24.23 ± 3.56 vs. -19.16 ± 8.25, P < 0.001) and global radial strain (RS) value (35.04 ± 11.16 vs. 29.58 ± 8.44, P = 0.009). It was found that nondipper status was associated with worsening of LS by 2.737, (P = 0.001), CS by 3.446, (P = 0.002), RS by -3.256, (P = 0.158) and DM also was found associated with worsening of LS by 1.849, (P = 0.062), CS by 3.284 (P = 0.018), RS by -2.499 (P = 0.381). CONCLUSION: The nondipping hypertension pattern is associated with subclinical LV systolic dysfunction as shown by the impaired global myocardial strain in all three directions.


Assuntos
Hipertensão , Disfunção Ventricular Esquerda , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Ecocardiografia , Humanos , Hipertensão/complicações , Hipertensão/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem
2.
Can J Cardiol ; 35(4): 389-395, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30852048

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) has been associated with cardiac rhythm device (CRD) implantation with intracardiac lead insertion. However, data on the incidence of postdevice TR are limited and largely from retrospective studies. We hypothesized that permanent lead implantation would be associated with an increase in TR. METHODS: We prospectively included consecutive patients with a clinical indication for CRD. Patients underwent transthoracic echocardiography 1 month before and 1 year after CRD implantation. RESULTS: A total of 328 patients were prospectively enrolled (69 ± 15 years, 38% female). Echocardiograms before and 1 year after CRD were available in 290 patients (15 died, 23 lost to follow-up). Compared with baseline, there was a significant change in TR grade 1 year after CRD insertion (no/trivial TR: 66% vs 29%; mild TR: 29% vs 61%; moderate TR: 3% vs 8%; severe TR 2% vs 2%; P < 0.001 for an increase in TR by at least 1 grade). Compared with baseline, there was a higher prevalence of moderate or severe TR in the 247 patients with CRD without cardiac resynchronization therapy (4% vs 10%, P = 0.004), but no progression in the 43 patients who received cardiac resynchronization therapy (14% vs 11%, P = 1). Multivariable analysis in the patients with less than moderate TR at baseline (n = 274) showed that only a history of atrial fibrillation was independently associated with progression to moderate or severe TR after correction for baseline TR grade (P = 0.013). CONCLUSIONS: One year after endocardial lead insertion, there was a 5% increase in the prevalence of moderate or severe TR, which may be clinically relevant.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide/epidemiologia , Idoso , Canadá/epidemiologia , Progressão da Doença , Ecocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Análise Multivariada , Prevalência , Estudos Prospectivos , Índice de Gravidade de Doença , Volume Sistólico , Insuficiência da Valva Tricúspide/classificação
3.
J Am Soc Echocardiogr ; 29(2): 158-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26615522

RESUMO

BACKGROUND: Low-flow low-gradient aortic stenosis (AS) is a predictor of worse outcome compared with normal-flow AS. Although depressed left ventricular ejection fraction (LVEF) is associated with low flow, there is less evidence to support the role of other indices of cardiac structure and function. METHODS: Clinical and echocardiographic data from patients with native AS and valve areas ≤ 1.0 cm(2) were retrospectively analyzed to identify characteristics that are associated with low-flow low-gradient AS. RESULTS: In total, 941 patients were included. On multivariate analysis, factors independently associated with low flow (stroke volume index < 35 mL/m(2)) included worse right ventricular systolic function, atrial fibrillation, lower LVEF, and higher left ventricular mass, with moderate or severe mitral regurgitation independently associated with low flow in the 694 patients (74%) with preserved LVEFs. CONCLUSIONS: Right ventricular dysfunction and atrial fibrillation are independently associated with low-flow low-gradient AS, while moderate or severe MR is independently associated with low flow in patients with preserved LVEF. These associations with low flow in AS are clinically important to recognize, to avoid underestimation of AS severity.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Comorbidade , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
7.
Glob Cardiol Sci Pract ; 2015(3): 41, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26779517

RESUMO

Given the increasing numbers of cardiac device implantations worldwide, it is important to determine whether permanent endocardial leads across the tricuspid valve can promote tricuspid regurgitation (TR). Virtually all current data is retrospective, and indicates a signal of TR being increased after permanent lead implantation. However, the precise incidence of moderate or greater TR post-procedure, the exact mechanisms (mechanical, traumatic, functional), and the hemodynamic burden and clinical effects of this putative increase in TR, remain uncertain. We have therefore designed a multicenter, international, prospective study of 300 consecutive patients (recruitment completed, baseline data presented) who will undergo echocardiography and clinical assessment prior to, and at 1-year post device insertion. This prospective study will help determine whether cardiac device-associated TR is real, what are its potential mechanisms, and whether it has an important clinical impact on cardiac device patients.

9.
J Infect Public Health ; 5(3): 250-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22632599

RESUMO

OBJECTIVE: Community-acquired pneumonia (CAP) is a major cause of morbidity and mortality worldwide. Herein, we present the findings from an audit of CAP management at a tertiary hospital in Oman. The main objective was to evaluate the quality of care given to patients and compare it with the standards in the Gulf Cooperation Council (GCC) CAP guidelines. METHODS: A retrospective case study of all patients admitted with CAP from June 2006 to September 2008 examined the adherence to standards for the diagnosis, investigation, and management of CAP, including the documentation of illness severity. RESULTS: The case notes of 342 patients were reviewed. Of these, 170 patients were excluded from the study, and 172 patients met the diagnostic criteria for inclusion. A CURB-65 severity score was documented for only 4 (2.3%) patients, and a smoking history was documented for 56 (32.6%) patients. Although 17 different antibiotic regimens were used, 115 (67%) patients received co-amoxiclav and clarithromycin, which is the standard of care. Additionally, 139 (81%) patients received their first dose of antibiotics within four hours of hospital admission. There was no documentation of offering influenza or pneumococcal vaccine to high risk patients. CONCLUSION: The clinical coding of CAP diagnosis was poor. There was very poor adherence to the CAP severity assessment and the provision of preventive measures upon hospital discharge. The development and implementation of a local hospital-based integrated care pathway may lead to more successful implementation of the guidelines.


Assuntos
Infecções Comunitárias Adquiridas/terapia , Auditoria Médica , Pneumonia/terapia , Guias de Prática Clínica como Assunto/normas , Qualidade da Assistência à Saúde/normas , Idoso , Combinação Amoxicilina e Clavulanato de Potássio/administração & dosagem , Combinação Amoxicilina e Clavulanato de Potássio/uso terapêutico , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Claritromicina/administração & dosagem , Claritromicina/uso terapêutico , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/tratamento farmacológico , Infecções Comunitárias Adquiridas/fisiopatologia , Gerenciamento Clínico , Feminino , Fidelidade a Diretrizes , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Omã , Pneumonia/diagnóstico , Pneumonia/tratamento farmacológico , Pneumonia/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa