RESUMO
A gas chromatography-atmospheric pressure photoionization-high-resolution mass spectrometry (GC-APPI-HRMS) method was developed for the determination of eight phenylalkylamine stimulants in urine samples. Spiked urine samples were hydrolyzed, processed by solid-phase extraction, and derivatized before analysis. Two derivatization reactions were studied: the formation of trimethylsilyl (TMS) derivatives with N-methyl-N-trimethylsilyl trifluoroacetamide (MSTFA) and trimethylsilyl/trifluoroacetyl (TMS/TFA) derivatives with MSTFA and N-methyl-bis (trifluoroacetamide) (MBTFA) as derivatization reagents. Gas chromatography of both derivatives was performed with a 100% dimethylsiloxane column and a good separation of all isomeric compounds was achieved. To maximize the signal of the protonated molecule [M+H]+, the APPI most critical parameters were optimized. Three solvents were tested as dopant agents, with acetone yielding the lower in-source collision-induced dissociation (CID) fragmentation. The acquisition was performed in full scan and product ion scan (parallel reaction monitoring, PRM) using a quadrupole-Orbitrap mass analyzer (35,000 FWHM at m/z 200) in positive ion detection mode. At the optimal working conditions, the full scan method was evaluated for the fulfillment of identification requirements in doping analysis. Selectivity, limits of detection, matrix effect, and precision were estimated to validate the method for confirmation purposes and its applicability was tested by the analysis of spiked samples as well as by the analysis of samples obtained after the administration of some of the compounds to healthy volunteers. Results were compared with those obtained by GC-electron ionization-MS, demonstrating that the GC-APPI-HRMS method improved selectivity and sensibility, achieving lower limits of detection and satisfactory reproducibility.
Assuntos
Estimulantes do Sistema Nervoso Central/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Pressão Atmosférica , Dopagem Esportivo , Feminino , Humanos , Hidroxilação , Limite de Detecção , Masculino , Padrões de Referência , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/métodosRESUMO
Nowadays most LC-MS methods rely on tandem mass spectrometry not only for quantitation and confirmation of compounds by multiple reaction monitoring (MRM), but also for the identification of unknowns from their product ion spectra. However, gas-phase reactions between charged and neutral species inside the mass analyzer can occur, yielding product ions at m/z values higher than that of the precursor ion, or at m/z values difficult to explain by logical losses, which complicate mass spectral interpretation. In this work, the formation of adduct ions in the mass analyzer was studied using several mass spectrometers with different mass analyzers (ion trap, triple quadrupole, and quadrupole-Orbitrap). Heterocyclic amines (AαC, MeAαC, Trp-P-1, and Trp-P-2), photo-initiators (BP and THBP), and pharmaceuticals (phenacetin and levamisole) were selected as model compounds and infused in LCQ Classic, TSQ Quantum Ultra AM, and Q-Exactive Orbitrap (ThermoFisher Scientific) mass spectrometers using electrospray as ionization method. The generation of ion-molecule adducts depended on the compound and also on the instrument employed. Adducts with neutral organic solvents (methanol and acetonitrile) were only observed in the ion trap instrument (LCQ Classic), because of the ionization source on-axis configuration and the lack of gas-phase barriers, which allowed inertial entrance of the neutrals into the analyzer. Adduct formation (only with water) in the triple quadrupole instruments was less abundant than in the ion trap and quadrupole-Orbitrap mass spectrometers, because of the lower residence time of the reactive product ions in the mass analyzer. The moisture level of the CID and/or damper gas had a great effect in beam-like mass analyzers such as triple quadrupole, but not in trap-like mass analyzers, probably because of the long residence time that allowed adduct formation even with very low concentrations of water inside the mass spectrometer.
RESUMO
Recreational drugs (illicit drugs, human and veterinary medicines, legal highs, etc.) often contain lacing agents and adulterants which are not related to the main active ingredient. Serious side effects and even the death of the consumer have been related to the consumption of mixtures of psychoactive substances and/or adulterants, so it is important to know the actual composition of recreational drugs. In this work, a method based on flow injection analysis (FIA) coupled with high-resolution mass spectrometry (HRMS) is proposed for the fast identification of psychoactive substances in recreational drugs and legal highs. The FIA and HRMS working conditions were optimized in order to detect a wide range of psychoactive compounds. As most of the psychoactive substances are acid-base compounds, methanol-0.1 % aqueous formic acid (1:1 v/v) as a carrier solvent and electrospray in both positive ion mode and negative ion mode were used. Two data acquisition modes, full scan at high mass resolution (HRMS) and data-dependent tandem mass spectrometry (ddMS/HRMS) with a quadrupole-Orbitrap mass analyzer were used, resulting in sufficient selectivity for identification of the components of the samples. A custom-made database containing over 450 substances, including psychoactive compounds and common adulterants, was built to perform a high-throughput target and suspect screening. Moreover, online accurate mass databases and mass fragmenter software were used to identify unknowns. Some examples, selected among the analyzed samples of recreational drugs and legal highs using the FIA-HRMS(ddMS/HRMS) method developed, are discussed to illustrate the screening strategy used in this study. The results showed that many of the analyzed samples were adulterated, and in some cases the sample composition did not match that of the supposed marketed substance.
Assuntos
Drogas Ilícitas/análise , Espectrometria de Massas em Tandem/métodosRESUMO
Liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) was applied to the analysis and authentication of fruit-based products and fruit-based pharmaceutical preparations. A Kinetex C18 reversed-phase column under gradient elution with 0.1 % formic acid aqueous solution and methanol mobile phases was used for the simultaneous determination of 26 polyphenols, allowing an acceptable separation in less than 22 min. Instrumental quality parameters such as limits of detection (LOD, values between 12 and 14 µg/L for 19 of the 26 analyzed polyphenols), linearity (r (2) > 0.991), run-to-run and day-to-day precisions (relative standard deviation (RSD) values lower than 9.9 and 13.5 %, respectively), and accuracy (relative errors lower than 8 %) were established. A simple extraction method, consisting of a sample sonication with acetone/water/hydrochloric acid (70:29.9:0.1 v/v/v) and centrifugation, was proposed. Two calibration procedures, external calibration using standards prepared in water and standard addition, were evaluated for polyphenol quantification in several grape and cranberry fruits and processed fruit products. For a 95 % confidence level, no statistical differences were observed between the two calibration methods (p values between 0.06 and 0.95), denoting that external calibration was suitable enough for the quantitative analysis of polyphenols in fruit-based products. The proposed LC-ESI-MS/MS method was then applied to the analysis of polyphenols in 23 grape-based and cranberry-based natural products and pharmaceutical preparations. Polyphenolic concentration data was then analyzed by principal component analysis (PCA) to extract information of the most significant profile data contributing to authentication of natural extracts according to their fruit of origin.
Assuntos
Cromatografia Líquida/métodos , Análise de Alimentos/métodos , Polifenóis/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Bebidas/análise , Calibragem , Fracionamento Químico , Frutas , Extratos Vegetais/análise , Extratos Vegetais/química , Análise de Componente Principal , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Vaccinium macrocarpon/química , Vitis/químicaRESUMO
A novel LC-MS/MS method has been developed for the determination of 13 aminoglycoside antibiotics in meat products. Among the chromatographic columns tested, the mixed-mode Obelisc R provided the best performance. Electrospray has been used for the coupling of the LC and the effect of temperature on the ionization has been evaluated. The mass spectra of AGs have been studied in order to select the most adequate precursor and product ions for quantitation and confirmation in SRM mode, showing that the single charged [M+H](+) provided better precisions than the double charged [M+2H](2+). Accurate mass measurements have been performed in order to confirm the molecular composition of the product ions, allowing the establishment of a new mechanism for some product ions of STR and DHSTR. A sample treatment based on an extraction and a SPE clean-up has been applied to a wide variety of meat products such as frankfurters; sausages; and minced meat of pork, veal, and chicken. Method limits of quantitation in the low microgram per kilogram level (1-50 µg kg(-1)), precisions %RSD below 15 % and accuracies expressed as relative errors below 23 % have been obtained, making the proposed method suitable for routine analysis.
Assuntos
Aminoglicosídeos/análise , Cromatografia Líquida/métodos , Carne/análise , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , AnimaisRESUMO
Sulfate metabolites of endogenous anabolic androgenic steroids (EAAS) have been shown to prolong the detection times compared with the conventional urinary markers of the steroid profile for oral and intramuscular administrations of testosterone (T). In this work, the sensitivity of sulfate EAAS markers for the detection of T gel administration has been evaluated in six Caucasian and six Asian male volunteers. Fourteen sulfate metabolites were measured in basal and post-administration samples after multiple doses of T gel (100 mg/day, three consecutive days), and the detection times based on individual thresholds for each volunteer were evaluated. Sulfate concentrations did not show adequate sensitivity, but the results of sulfate ratios were much more promising. Androsterone sulfate/testosterone sulfate (A-S/T-S), epiandrosterone sulfate/epitestosterone sulfate (epiA-S/E-S), epiA-S/T-S, and etiocholanolone sulfate/epitestosterone sulfate (Etio-S/E-S) provided the most consistent detectability for all volunteers and populations, with detection times ranging from 60 to 96 h since the first dose. Additional ratios improved detectability to up to 7 days, but only in particular volunteers. In general, sensitivity was similar to or better than the conventional testosterone/epitestosterone ratio (T/E) of the steroid profile, which further reinforces the conclusion that sulfate EAAS metabolites can be a good complement for the current steroid profile.
RESUMO
Background: Erythropoietin receptor agonists (ERAs) are substances prohibited in sports and currently monitored in urine and blood. There is a great interest in new matrices like dried blood spots (DBSs). Method: A direct method for the detection of ERAs in DBSs using one single spot of 25 µl has been optimized and validated. Results: Limits of detection close or equal to those required by the World Anti-Doping Agency for serum/plasma samples were achieved, using a volume 20-times lower. All analytes were stable for at least 90 days at room temperature. Conclusion: Method performance was comparable to the requirements established for blood samples and, thus, monitoring of ERAs is reliable in DBSs in the context of doping control.
Assuntos
Líquidos Corporais , Dopagem Esportivo , Dopagem Esportivo/prevenção & controle , Dopagem Esportivo/métodos , Receptores da Eritropoetina , Teste em Amostras de Sangue Seco/métodos , PlasmaRESUMO
In this work, desorption electrospray ionization and paper spray ionization both with high-resolution mass spectrometry (DESI-HRMS and PSI-HRMS) were explored for the fast and direct analysis of stimulants and diuretics in urine samples. The analysis was performed at a resolution of 70 000 FWHM (m/z 200) using a quadrupole-Orbitrap mass spectrometer in full scan acquisition mode, detecting stimulants and diuretics in positive and negative ion modes, respectively. The most critical parameters affecting the desorption and ionization efficiencies of compounds were optimized, paying particular attention to the optimization of the spray solvent for PSI-HRMS analysis and to the selection of the DESI sample substrate. For stimulants, the PSI-HRMS method performed better than DESI-HRMS, allowing the direct analysis of raw urine samples with better signal-to-noise ratios than DESI. However, results obtained for diuretics were not as satisfactory as we expected. The PSI-HRMS method was applied to the screening of 52 stimulants for doping control purposes, providing satisfactory detectability for most of them at the Minimum Reporting Level (MRL) in less than 2 minutes for each single analysis. Despite the advantages offered by the PSI-HRMS method, in this study is also included a discussion on the limitations observed because of the presence of interference for some compounds.
Assuntos
Estimulantes do Sistema Nervoso Central , Dopagem Esportivo , Espectrometria de Massas por Ionização por Electrospray/métodos , Dopagem Esportivo/prevenção & controle , Diuréticos , Razão Sinal-RuídoRESUMO
In this work, the collision cross section (CCS) value of 103 steroids (including unconjugated metabolites and phase II metabolites conjugated with sulfate and glucuronide groups) was determined by liquid chromatography coupled to traveling wave ion mobility spectrometry (LC-TWIMS). A time of flight (QTOF) mass analyzer was used to perform the analytes determination at high-resolution mass spectrometry. An electrospray ionization source (ESI) was used to generate [M+H]+, [M + NH4]+ and/or [M - H]- ions. High reproducibility was observed for the CCS determination in both urine and standard solutions, obtaining RSD lower than 0.3% and 0.5% in all cases respectively. CCS determination in matrix was in accordance with the CCS measured in standards solution showing deviations below 2%. In general, CCS values were directly correlated with the ion mass and allowed differentiating between glucuronides, sulfates and free steroids although differences among steroids of the same group were less significant. However, more specific information was obtained for phase II metabolites observing differences in the CCS value of isomeric pairs concerning the conjugation position or the α/ß configuration, which could be useful in the structural elucidation of new steroid metabolites in the anti-doping field. Finally, the potential of IMS reducing interferences from the sample matrix was also tested for the analysis of a glucuronide metabolite of bolasterone (5ß-androstan-7α,17α-dimethyl-3α,17ß-diol-3-glucuronide) in urine samples.
Assuntos
Glucuronídeos , Esteroides , Glucuronídeos/química , Glucuronídeos/urina , Reprodutibilidade dos Testes , Espectrometria de Massas , Cromatografia Líquida/métodos , Sulfatos/químicaRESUMO
A method based on ultra-high performance liquid chromatography (UHPLC) is proposed for the determination of chloramphenicol (CAP), its related compounds, thiamphenicol (TAP) and florfenicol (FF), and the polar metabolite florfenicol-amine (FFA), in animal-derived foods (chicken and pork meat, fish, prawns and honey). For the retention of FFA and its simultaneous analysis with the parent compounds a phenyl-hexyl column is proposed. A fast separation is achieved in less than 2 minutes using a methanol : acetic acid-ammonium acetate buffer (5 mM, pH 5) and gradient elution. Under these conditions, the FFA is retained at more than twice the dead volume, as recommended by the legislation. For the coupling with mass spectrometry, heated-electrospray (H-ESI) is used as ionisation source improving vaporization efficiency. To prevent interferences using selected-reaction monitoring (SRM) both quantitation and confirmation transitions were carefully selected. Two different sample treatments based on solid-phase extraction with mixed-mode cartridges for fish and meat products and hydrophilic-lipophilic-balanced cartridges for honey are proposed, providing limits of quantitation (LOQs) below µg kg(-1) level.
Assuntos
Antibacterianos/análise , Cromatografia Líquida de Alta Pressão , Análise de Alimentos , Espectrometria de Massas em Tandem , Tianfenicol/análogos & derivados , Animais , Antibacterianos/isolamento & purificação , Antibacterianos/metabolismo , Galinhas , Cloranfenicol/análise , Cloranfenicol/isolamento & purificação , Cloranfenicol/metabolismo , Peixes , Mel/análise , Carne/análise , Extração em Fase Sólida , Suínos , Tianfenicol/análise , Tianfenicol/isolamento & purificaçãoRESUMO
Betamethasone (BET) is prohibited in sports competitions when administered by systemic routes, and it is allowed by other routes for therapeutic purposes. In out-of-competition periods, there is no restriction of use. The present work aimed to assess the urinary excretion of BET and its metabolites after allowed and prohibited administrations to verify the suitability of the current reporting level of 30 ng/ml used to distinguish allowed and prohibited administrations and to establish washout periods for oral and intramuscular (IM) administrations when out-of-competition treatments are needed. BET was administered to healthy volunteers by different routes: topical (10 mg/day for 5 days, n = 6 males), intranasal (320 µg/day for 3 days, n = 4 males and 4 females), oral (0.5 mg, n = 8 males) or IM (6 mg, n = 6 males, or 12 mg, n = 4 males and 4 females). Urine and plasma samples collected before and after administration were analysed using liquid chromatography-tandem mass spectrometry. Among all studied metabolites, the parent drug was selected as the best discriminatory marker. After topical administration, BET concentrations were lower than 6.6 ng/ml. However, after intranasal treatment, some samples at concentrations close to or higher than 30 ng/ml were detected, suggesting the need to revise the current reporting level. Urinary concentrations after oral and intranasal administrations were similar, and after IM administration, concentrations were much higher. Taking into account all information, a urinary reporting level of 60 ng/ml is proposed. Washout periods of at least 48 and 96 h are recommended after oral and IM administrations, respectively.
Assuntos
Betametasona/administração & dosagem , Betametasona/urina , Glucocorticoides/administração & dosagem , Glucocorticoides/urina , Administração Intranasal , Administração Oral , Administração Tópica , Betametasona/sangue , Cromatografia Líquida/métodos , Monitoramento de Medicamentos/métodos , Feminino , Glucocorticoides/sangue , Humanos , Injeções Intramusculares , Limite de Detecção , Masculino , Espectrometria de Massas em Tandem/métodosRESUMO
Prednisolone (PRED) and prednisone (PSONE) are prohibited in sports competitions when administered by systemic routes, and they are allowed by other routes for therapeutic purposes. There is no restriction of use in out-of-competition periods. The present study aimed to evaluate the urinary excretion of PRED, PSONE, and their most important metabolites after systemic and nonsystemic treatments in order to verify the suitability of the current reporting level of 30 ng/ml used to distinguish allowed and prohibited administrations and to establish washout periods for oral treatments performed in out-of-competition periods. PRED was studied after dermatological administration (5 mg/day for 5 days, n = 6 males) and oral administration (5 mg, n = 6 males; 10 mg, n = 2 males). PSONE was studied after oral administration (10 mg, n = 2 males; 30 mg, n = 1 male and 1 female). Concentrations in urine were measured using an LC-MS/MS method. Concentrations after dermatological treatment were low for all metabolites. After oral administration, concentrations were very high during the first 24 h after administration ranging from 1.6 to 2261 ng/ml and from 4.6 to 908 ng/ml for PRED and PSONE, respectively. Concentrations of most of the metabolites measured were lower than 30 ng/ml from 24 h after all oral administrations. New reporting levels are proposed for PRED and PSONE considering data of our study and other information published after nonsystemic administrations of the compounds. Washout periods of at least 24 h are recommended to ensure no false positives when oral treatments need to be performed in out-of-competition periods.
Assuntos
Cromatografia Líquida/métodos , Prednisolona/urina , Prednisona/urina , Espectrometria de Massas em Tandem/métodos , Administração Cutânea , Administração Oral , Estudos Cross-Over , Dopagem Esportivo/prevenção & controle , Feminino , Humanos , Masculino , Prednisolona/administração & dosagem , Prednisolona/metabolismo , Prednisona/administração & dosagem , Prednisona/metabolismo , Detecção do Abuso de Substâncias/métodos , Fatores de TempoRESUMO
Growth hormone-releasing hormone and its analogues sermorelin, tesamorelin and CJC-1295 are included in the prohibited list of the World Antidoping Agency. These target peptides are found at very low concentrations in urine (at the pg/mL level). For this reason, hyphenated enrichment and purification steps prior to mass spectrometric detection are required. Among different strategies, immunopurification based on magnetic beads is an excellent alternative, as it offers improved selectivity when the immunoreactivity and orientation of the antibody are optimum and non-specific adsorption is minimized. However, choosing the magnetic bead surface functionalities that provide the best recoveries is not so straightforward. In this work, we have evaluated the suitability of magnetic beads with different supports, binding capacities and affinity chemistries prior analysis of human urine samples by liquid chromatography coupled to high resolution mass spectrometry using a Quadrupole-Orbitrap instrument. After optimization of the immunopurification protocol with the magnetic beads that provided better recoveries, the method was fully validated and found to be adequate considering the parameters specificity, intra- and inter-day precision (lower than 15 and 25%, respectively), matrix effect, limit of detection (0.2 ng/mL) and limit of identification (0.5 ng/mL).
Assuntos
Dopagem Esportivo , Detecção do Abuso de Substâncias , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Hormônio Liberador de Hormônio do Crescimento , Humanos , Limite de Detecção , Fenômenos Magnéticos , Espectrometria de Massas , Reprodutibilidade dos TestesRESUMO
The detection of testosterone (T) misuse is performed using the steroid profile that includes concentrations of T and related metabolites excreted free and glucuronoconjugated, and the ratios between them. In this work, the usefulness of 14 endogenous steroid sulfates to improve the detection capabilities of oral T administration has been evaluated. Quantitation of the sulfate metabolites was performed using solid-phase extraction and analysis by liquid chromatography-tandem mass spectrometry. Urine samples were collected up to 144 hours after a single oral dose of T undecanoate (120 mg) to five Caucasian male volunteers. Detection times (DTs) of each marker were estimated using reference limits based on a population study and also monitoring the individual threshold for each volunteer. High inter-individual variability was observed for sulfate metabolites and, therefore, better DTs were obtained using individual thresholds. Using individual threshold limits, epiandrosterone sulfate (epiA-S) improved the DT with respect to testosterone/epitestosterone (T/E) ratio in all volunteers. Androsterone, etiocholanolone, and two androstanediol sulfates also improved DTs for some volunteers. Principal component analysis was used to characterize the sample cohort, obtaining 13 ratios useful for discrimination. These ratios as well as the ratio epiA-S/dehydroepiandrosterone sulfate were further examined. The most promising results were obtained using ratios between sulfates of epiA, androsterone, or androstanediol 1 and E, and also sulfates of epiA or androstanediol 1, and dehydroandrosterone. These selected ratios prolonged the DT of oral T administration up to 144 hours, which corresponded to a significantly higher retrospectivity compared to those obtained using concentrations or the conventional T/E ratio.
Assuntos
Detecção do Abuso de Substâncias/métodos , Sulfatos/metabolismo , Sulfatos/urina , Testosterona/administração & dosagem , Testosterona/metabolismo , Administração Oral , Cromatografia Líquida , Humanos , Masculino , Análise de Componente Principal , Extração em Fase Sólida , Sulfatos/química , Espectrometria de Massas em Tandem , Testosterona/análogos & derivados , Testosterona/urinaRESUMO
The introduction of alternative markers to the steroid profile can be an effective approach to improving the screening capabilities for the detection of testosterone (T) misuse. In this work, endogenous steroid sulfates were evaluated as potential markers to detect intramuscular (IM) T administration. Fourteen sulfate metabolites were quantified using mixed-mode solid-phase extraction and analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Urine samples after a single IM injection (100 mg) of T cypionate to six Caucasian and six Asian healthy male volunteers were analyzed. Principal component analysis (PCA) was used to characterize the sample cohort and to obtain the most useful markers for discrimination between pre- and post-administration samples. For Caucasian volunteers, a separation between pre- and post-administration samples was observed in PCA, whereas for Asian volunteers no separation was obtained. Seventeen ratios between sulfate metabolites were selected and further considered. Detection times (DTs) of each marker were evaluated using individual thresholds for each volunteer. The best results were obtained using ratios involving T and epitestosterone (E) sulfates in the denominator. The best marker was the ratio androsterone sulfate/testosterone sulfate (A-S/T-S) which prolonged the DT 1.2-2.1 times in respect to those obtained using T/E ratio in all Caucasian volunteers and 1.3-1.5 times in two Asian volunteers. Other ratios between A-S or etiocholanolone sulfate and E-S, and sulfates of etiocholanolone, dehydroandrosterone or epiandrosterone, and T-S were also found adequate. These ratios improve the DT after IM T administration and their incorporation to complement the current steroid profile is recommended.
Assuntos
Anabolizantes/urina , Androgênios/urina , Epitestosterona/urina , Sulfatos/urina , Testosterona/urina , Anabolizantes/administração & dosagem , Anabolizantes/metabolismo , Androgênios/administração & dosagem , Androgênios/metabolismo , Povo Asiático , Cromatografia Líquida , Dopagem Esportivo , Epitestosterona/administração & dosagem , Epitestosterona/metabolismo , Humanos , Injeções Intramusculares , Masculino , Detecção do Abuso de Substâncias , Sulfatos/metabolismo , Espectrometria de Massas em Tandem , Testosterona/administração & dosagem , Testosterona/metabolismo , População BrancaRESUMO
Triamcinolone acetonide (TA) is a glucocorticoid (GC) widely used in sports medicine. GCs are prohibited in sports competitions by oral, intramuscular (IM), intravenous and rectal administrations, and they are allowed by other routes considered of local action such as intranasal administration (INT). We examined the urinary profiles of TA and its metabolites after INT and high-dose IM administrations. We also measured concentrations of TA and cortisol (CORT) in plasma following IM administration. TA was administered to healthy volunteers using INT route (220⯵g/day for 3â¯days, nâ¯=â¯4 males and 4 females) or IM route (single dose of 40â¯mg, nâ¯=â¯4 males and 4 females and single dose 80â¯mg, nâ¯=â¯4 males). Urine and plasma samples were collected before and after administration at different time periods, and were analysed by liquid chromatography-tandem mass spectrometry. TA concentrations in urine were constant during 23â¯days after IM injection (range 1.4-129.0â¯ng/mL), and were very low after INT administration (range 0.0-3.5â¯ng/mL). For 6ß-hydroxy-triamcinolone, the main TA metabolite, higher concentrations were detected (0.0-93.7â¯ng/mL and 15.7-973.9â¯ng/mL after INT and IM administrations, respectively). On the other hand, TA was detected in all plasma samples collected during 23â¯days after IM administration (range 0.2-5.7â¯ng/mL). CORT levels were largely suppressed after IM injection, and were recovered in a dose-dependent manner. In view of the results obtained, we propose a reporting level of 5â¯ng/mL for TA to distinguish forbidden from allowed TA administrations in sports. We also suggest that other GCs with faster urinary elimination from the body should be considered for IM therapies in out-of-competition rather than TA, in order to reduce the possibility of reporting false adverse analytical findings.
Assuntos
Administração Intranasal , Uso Indevido de Medicamentos , Injeções Intramusculares , Esportes , Triancinolona Acetonida/administração & dosagem , Triancinolona Acetonida/urina , Adulto , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Triancinolona Acetonida/metabolismoRESUMO
A method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the direct quantitation of endogenous steroid sulfates has been developed to be able to evaluate these metabolites as biomarkers to detect the misuse of endogenous androgenic anabolic steroids in sports. For sample preparation, a mixed-mode solid-phase extraction was optimized to eliminate the glucuronide fraction in the washing step thus obtaining only the sulfate fraction. Chromatographic separation was optimized to achieve adequate resolution between isomers. The electrospray ionization and the product ion mass spectra of the sulfates were studied in order to obtain the most specific and selective transitions. The method was validated for quantitative purposes for 11 steroid sulfates obtaining satisfactory values for linearity, accuracy, and intra- and inter-day precision (relative standard deviation better than 16.2%). Limits of quantitation ranged between 0.5 and 2 ng/mL. Extraction recoveries for sulfate metabolites were between 90 and 94%. Matrix effect ranged from 90 to 110% showing the absence of significant ion suppression/enhancement. Samples were found to be stable after 2 freeze/thaw cycles. The applicability of the method was checked by the analysis of 75 urine samples from healthy volunteers (54 males, 37 Caucasian and 17 Asian, and 21 Caucasian females) to evaluate the concentration levels of endogenous sulfate metabolites in basal conditions.
Assuntos
Anabolizantes/urina , Espectrometria de Massas por Ionização por Electrospray/métodos , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Sulfatos/urina , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Dopagem Esportivo , Feminino , Humanos , Limite de Detecção , Masculino , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodosRESUMO
The traditional Watson-Crick base pairs in DNA may occasionally adopt a Hoogsteen conformation, with a different organization of hydrogen bonds. Previous crystal structures have shown that the Hoogsteen conformation is favored in alternating AT sequences of DNA. Here we present new data for a different sequence, d(ATTAAT)2, which is also found in the Hoogsteen conformation. Thus we demonstrate that other all-AT sequences of DNA with a different sequence may be found in the Hoogsteen conformation. We conclude that any all-AT sequence might acquire this conformation under appropriate conditions. We also compare the detailed features of DNA in either the Hoogsteen or Watson-Crick conformations.
Assuntos
Pareamento de Bases , DNA/química , Ligação de HidrogênioRESUMO
Fifty samples of finished drinking waters (FDWs) from Spain covering 12 million inhabitants were tested for 53 pharmaceuticals pertaining to 12 different Anatomical Therapeutic Chemical (ATC) classification system codes. The studied compounds are a combination of most commonly consumed pharmaceuticals with other barely reported in the literature. Five compounds, azithromycin, clarithromycin, erythromycin, sulfamethoxazole, and ibuprofen were tentatively identified by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in some samples (2 to 15 %), but only ibuprofen and azithromycin could be confirmed when analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) with a quadrupole-Orbitrap instrument. Concentration levels of ibuprofen in the positive samples ranged from 12 to 17 ng/L (n = 6) while for azithromycin values from 5 to 9.5 ng/L (n = 3) were found. Ibuprofen fragmentation behaviour in different mass spectrometry instrument configurations (triple quadrupole, quadrupole-ion trap, and quadrupole-Orbitrap) was evaluated.
Assuntos
Água Potável/química , Monitoramento Ambiental/estatística & dados numéricos , Preparações Farmacêuticas/análise , Poluentes Químicos da Água/análise , Azitromicina/análise , Cromatografia Líquida/métodos , Claritromicina/análise , Monitoramento Ambiental/métodos , Eritromicina/análise , Ibuprofeno/análise , Espanha , Sulfametoxazol/análise , Espectrometria de Massas em Tandem/métodosRESUMO
In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H](+) dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M-H](-), while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high-resolution mass spectrometry in a quadrupole-Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N-(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS(3) and MS(4) spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high-performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg.