Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 189: 425-431, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30682536

RESUMO

Spectral editing allows direct measurement of low-concentration metabolites, such as GABA, glutathione (GSH) and lactate (Lac), relevant for understanding brain (patho)physiology. The most widely used spectral editing technique is MEGA-PRESS, which has been diversely implemented across research sites and vendors, resulting in variations in the final resolved edited signal. In this paper, we describe an effort to develop a new universal MEGA-PRESS sequence with HERMES functionality for the major MR vendor platforms with standardized RF pulse shapes, durations, amplitudes and timings. New RF pulses were generated for the universal sequence. Phantom experiments were conducted on Philips, Siemens, GE and Canon 3 T MRI scanners using 32-channel head coils. In vivo experiments were performed on the same six subjects on Philips and Siemens scanners, and on two additional subjects, one on GE and one on Canon scanners. On each platform, edited MRS experiments were conducted with the vendor-native and universal MEGA-PRESS sequences for GABA (TE = 68 ms) and Lac editing (TE = 140 ms). Additionally, HERMES for GABA and GSH was performed using the universal sequence at TE = 80 ms. The universal sequence improves inter-vendor similarity of GABA-edited and Lac-edited MEGA-PRESS spectra. The universal HERMES sequence yields both GABA- and GSH-edited spectra with negligible levels of crosstalk on all four platforms, and with strong agreement among vendors for both edited spectra. In vivo GABA+/Cr, Lac/Cr and GSH/Cr ratios showed relatively low variation between scanners using the universal sequence. In conclusion, phantom and in vivo experiments demonstrate successful implementation of the universal sequence across all four major vendors, allowing editing of several metabolites across a range of TEs.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/normas , Adulto , Feminino , Glutationa/metabolismo , Humanos , Ácido Láctico/metabolismo , Espectroscopia de Ressonância Magnética/instrumentação , Masculino , Ácido gama-Aminobutírico/metabolismo
2.
Magn Reson Med ; 81(4): 2600-2613, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30506877

RESUMO

PURPOSE: CEST MRI allows for indirect detection of molecules with exchangeable protons, measured as a reduction in water signal because of continuous transfer of saturated protons. CEST requires saturation pulses on the order of a second, as well as repeated acquisitions at different offset frequencies. The resulting extended scan time makes CEST susceptible to subject motion, which introduces field inhomogeneity, shifting offset frequencies and causing distortions in CEST spectra that resemble true CEST effects. This is a particular problem for molecules that resonate close to water, such as hydroxyl group in glycogen. To address this, a technique for real-time measurement and correction of motion and field inhomogeneity is proposed. METHODS: A CEST sequence was modified to include double volumetric navigators (DvNavs) for real-time simultaneous motion and shim correction. Phantom tests were conducted to investigate the effects of motion and shim changes on CEST quantification and to validate the accuracy of DvNav motion and shim estimates. To evaluate DvNav shim and motion correction in vivo, acquisitions including 5 experimental conditions were performed in the calf muscle of 2 volunteers. RESULTS: Phantom data show that DvNav-CEST accurately estimates frequency and linear gradient changes because of motion and corrects resulting image distortions. In addition, DvNav-CEST improves CEST quantification in vivo in the presence of motion. CONCLUSION: The proposed technique allows for real-time simultaneous motion and shim correction with no additional scanning time, enabling accurate CEST quantification even in the presence of motion and field inhomogeneity.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Movimento (Física) , Músculo Esquelético/patologia , Adulto , Algoritmos , Artefatos , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Modelos Lineares , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Endocr Connect ; 10(5): 550-560, 2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-33884957

RESUMO

The role of ectopic fat, insulin secretion and clearance in the preservation ofß-cell function in black African women with obesity who typically present with hyperinsulinaemia is not clear. We aim to examine the associations between disposition index (DI, an estimate of ß-cell function), insulin secretion and clearance and ectopic fat deposition. This is a cross-sectional study of 43 black South African women (age 20-35 years) with obesity (BMI 30-40 kg/m2) and without type 2 diabetes that measured the following: DI, insulin sensitivity (SI), acute insulin response (AIRg), insulin secretion rate (ISR), hepatic insulin extraction and peripheral insulin clearance (frequently sampled i.v. glucose tolerance test); pancreatic and hepatic fat, visceral adipose tissue (VAT) and abdominal s.c. adipose tissue (aSAT) volume (MRI), intra-myocellular (IMCL) and extra-myocellular fat content (EMCL) (magnetic resonance spectroscopy). DI correlated positively with peripheral insulin clearance (ß 55.80, P = 0.002). Higher DI was associated with lower VAT, pancreatic fat and soleus fat, but VAT explained most of the variance in DI (32%). Additionally, higher first phase ISR (P = 0.033) and lower hepatic insulin extraction (P = 0.022) were associated with lower VAT, independent from SI, rather than with ectopic fat. In conclusion, peripheral insulin clearance emerged as an important correlate of DI. However, VAT was the main determinant of a lower DI above ectopic fat depots. Importantly, VAT, but not ectopic fat, is associated with both lower insulin secretion and higher hepatic insulin extraction. Prevention of VAT accumulation in young black African women should, therefore, be an important target for beta cell preservation.

4.
Quant Imaging Med Surg ; 9(10): 1674-1685, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31728311

RESUMO

BACKGROUND: Repeated glycoCEST MRI measurements on the same subject should produce similar results under the same environmental and experimental conditions. However, fluctuations in the static B0 field, which may occur between and within measurements due to heating of the shim iron or subject motion, may alter results and affect reproducibility. Here we investigate the repeatability and reproducibility of glycoCEST measurements and examine the effectiveness of a real-time shim- and motion navigated chemical exchange saturation transfer (CEST) sequence to improve reproducibility. METHODS: In nine subjects, double volumetric navigated (DvNav)-CEST acquisitions in the calf muscle were repeated five times in each of two sessions-the first without correction, and the second with real-time shim- and motion correction applied. In both sessions a dynamically changing field was introduced by running a 5-minute gradient intensive diffusion sequence. We evaluated the effect of the introduced B0 inhomogeneity on the reproducibility of glycoCEST, where the small chemical shift difference between the hydroxyl and bulk water protons at 3 T makes CEST quantification extremely sensitive to magnetic field inhomogeneities. RESULTS: With real-time shim- and motion correction, glycoCEST results were relatively consistent with mean coefficient of variation (CoV) 2.7%±1.4% across all subjects, whereas without correction the results were less consistent with CoV 84%±71%. CONCLUSIONS: Our results demonstrate that real-time shim- and motion correction can mitigate effects of B0 field fluctuations and improve reproducibility of glycoCEST data. This is important when conducting longitudinal studies or when using glycoCEST MRI to assess treatment or physiological responses over time.

5.
JMIR Res Protoc ; 7(4): e75, 2018 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-29669711

RESUMO

BACKGROUND: The pathogenesis of type 2 diabetes (T2D) in black African women is complex and differs from that in their white counterparts. However, earlier studies have been cross-sectional and provide little insight into the causal pathways. Exercise training is consistently used as a model to examine the mechanisms underlying insulin resistance and risk for T2D. OBJECTIVE: The objective of the study was to examine the mechanisms underlying the changes in insulin sensitivity and secretion in response to a 12-week exercise intervention in obese black South African (SA) women. METHODS: A total of 45 obese (body mass index, BMI: 30-40 kg/m2) black SA women were randomized into a control (n=22) or experimental (exercise; n=23) group. The exercise group completed 12 weeks of supervised combined aerobic and resistance training (40-60 min, 4 days/week), while the control group maintained their typical physical activity patterns, and both groups were requested not to change their dietary patterns. Before and following the 12-week intervention period, insulin sensitivity and secretion (frequently sampled intravenous glucose tolerance test) and its primary and secondary determinants were measured. Dietary intake, sleep quality and quantity, physical activity, and sedentary behaviors were measured every 4 weeks. RESULTS: The final sample included 20 exercise and 15 control participants. Baseline sociodemographics, cardiorespiratory fitness, anthropometry, cardiometabolic risk factors, physical activity, and diet did not differ between the groups (P>.05). CONCLUSIONS: The study describes a research protocol for an exercise intervention to understand the mechanisms underlying insulin sensitivity and secretion in obese black SA women and aims to identify causal pathways underlying the high prevalence of insulin resistance and risk for T2D in black SA women, targeting specific areas for therapeutic intervention. TRIAL REGISTRATION: Pan African Clinical Trial Registry PACTR201711002789113; http://www.pactr.org/ATMWeb/ appmanager/atm/atmregistry?_nfpb=true&_pageLabel=portals_app_atmregistry_portal_page_13 (Archived by WebCite at http://www.webcitation.org/6xLEFqKr0).

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa