Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38287171

RESUMO

The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the traditional transvenous implantable cardioverter defibrillator (TV-ICD), aiming to provide easier implantation, simplified detection algorithm of malignant ventricular arrhythmias and prevention from placing components in the cardiovascular system. The S-ICD is implanted subcutaneously or intramuscularly with the generator placed in the left midaxillary line and the lead tunneled subcutaneously in the left para-sternal region. Preimplant electrocardiogram screening is recommended to prevent implantation in patients at high risk of T wave over-sensing. Currently, the S-ICD is unsuitable for patients requiring pacing or cardiac resynchronization. Since the beginning, the S-ICD underwent extensive preclinical investigation until the first prospective multicentre trial demonstrating high efficacy and safety led to market release. While earlier studies focused on younger patients with higher ejection fraction, more recent studies showed favorable outcomes even in patients with comorbidities similar to those typically observed in patients receiving TV-ICD. The development of second and third generation devices has contributed to reduce inappropriate shocks and overcome previous limitations. The aim of this paper is to review the evidence in the literature over the past decade supporting S-ICD as a valid alternative to TV-ICD in terms of safety and efficacy, highlighting the improvements in technology, as well as outcomes.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Morte Súbita Cardíaca/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Multicêntricos como Assunto
2.
J Cardiovasc Electrophysiol ; 34(3): 598-606, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640425

RESUMO

INTRODUCTION: Despite numerous ECG algorithms being developed to localize the site of manifest accessory pathways (AP), they often require stepwise multiple-lead analysis with variable accuracy, limitations, and reproducibility. The study aimed to develop a single-lead ECG algorithm incorporating the P-Delta interval (PDI) as an adjunct criterion to discriminate between right and left manifest AP. METHODS: Consecutive WPW patients undergoing electrophysiological study (EPS) were retrospectively recruited and split into a derivation and validation group (1:1 ratio). Sinus rhythm ECG analysis in lead V1 was performed by three independent investigators blinded to the EPS results. Conventional ECG parameters and PDI were assessed through the global cohort. RESULTS: A total of 140 WPW patients were included (70 for each group). A score-based, single-lead ECG algorithm was developed through derivation analysis incorporating the PDI, R/S ratio, and QRS onset polarity in lead V1. The validation group analysis confirmed the proposed algorithm's high accuracy (95%), which was superior to the previous ones in predicting the AP side (p < 0.05). A score of ≤+1 was 96.5% accurate in predicting right AP while a score of ≥+2 was 92.5% accurate in predicting left AP. The new algorithm maintained optimal performance in specific subgroups of the global cohort showing an accuracy rate of 90%, 92%, and 96% in minimal pre-excitation, posteroseptal AP, and pediatric patients, respectively. CONCLUSIONS: A novel single-lead ECG algorithm incorporating the PDI interval with previous conventional criteria showed high accuracy in differentiating right from left manifest AP comprising pediatric and minimal pre-excitation subgroups in the current study.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Criança , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Algoritmos , Síndrome de Wolff-Parkinson-White/cirurgia
3.
J Cardiovasc Electrophysiol ; 34(11): 2316-2329, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37655997

RESUMO

The right bundle branch (RBB), due to its endocardial course, is susceptible to traumatic block caused by "bumping" during right-heart catheterization. In the era of cardiac electrophysiology, catheter-induced RBB block (CI-RBBB) has become a common phenomenon observed during electrophysiological studies and catheter ablation procedures. While typically transient, it may persist for the entire procedure time. Compared to pre-existing RBBB, the transient nature of CI-RBBB allows for comparative analysis relative to the baseline rhythm. Furthermore, unlike functional RBBB, it occurs at similar heart rates, making the comparison of conduction intervals more reliable. While CI-RBBB can provide valuable diagnostic information in various conditions, it is often overlooked by cardiac electrophysiologists. Though it is usually a benign and self-limiting conduction defect, it may occasionally lead to diagnostic difficulties, pitfalls, or undesired consequences. Avoidance of CI-RBBB is advised in the presence of baseline complete left bundle branch block and when approaching arrhythmic substrates linked to the right His-Purkinje-System, such as fasciculo-ventricular pathways, bundle branch reentry, and right-Purkinje focal ventricular arrhythmias. This article aims to provide a comprehensive practical review of the electrophysiological phenomena related to CI-RBBB and its impact on the intrinsic conduction system and various arrhythmic substrates.


Assuntos
Bloqueio de Ramo , Sistema de Condução Cardíaco , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração , Cateterismo Cardíaco/efeitos adversos , Catéteres , Eletrocardiografia
4.
Pacing Clin Electrophysiol ; 46(10): 1230-1234, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36788778

RESUMO

Catheter ablation (CA) of left atrial tachycardia adjacent to implanted septal closure devices represents a multifaceted challenge. We describe the case of a 57-year-old patient with remote percutaneous closure of atrial septal defect who underwent successful CA of left atrial tachycardia adjacent to the septal device using a transaortic approach and RF energy. Besides the technical difficulties and associated risks, interference between the device and applied RF parameters may limit ablation efficiency. Further research is required to evaluate the safety, efficacy, and optimal energy type/parameters when ablating arrhythmias adjacent to these devices.


Assuntos
Ablação por Cateter , Comunicação Interatrial , Taquicardia Supraventricular , Humanos , Pessoa de Meia-Idade , Taquicardia/cirurgia , Taquicardia Supraventricular/cirurgia , Arritmias Cardíacas/cirurgia , Comunicação Interatrial/cirurgia , Resultado do Tratamento
5.
Europace ; 24(10): 1608-1616, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35639806

RESUMO

AIMS: Air entrapment (AE) has been reported as a potential cause of early inappropriate shocks (ISs) following subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, but a cause-effect relationship is not always evident. This systematic review aims to analyse this phenomenon concerning implantation techniques, electrogram (EGM) features, radiologic findings, and patient management. METHODS AND RESULTS: A systematic search was conducted using PubMed, Embase, and Google Scholar databases following the PRISMA guidelines to obtain all available literature data since 2010 on S-ICD malfunctions possibly due to AE. The final analysis included 54 patients with AE as a potential cause of S-ICD malfunction. Overall, the aggregate incidence of this condition was 1.2%. Of ICD malfunctions possibly due to AE, 93% were ISs, and 95% were recorded within the first week following implantation. Radiologic diagnosis of AE was confirmed in 28% of the entire study cohort and in 68% of patients in whom this diagnostic examination was reported. At the time of device malfunction, EGMs showed artefacts, baseline drift, and QRS voltage reduction in 95, 76, and 67% of episodes, respectively. Management included ICD reprogramming or testing, no action (observation), and invasive implant revision in 57, 33, and 10% of patients, respectively. No recurrences occurred during follow-up, irrespective of management performed. CONCLUSIONS: Device malfunction possibly due to AE may occur in ∼1% of S-ICD recipients. Diagnosis is strongly suggested by early occurrence, characteristic EGM features, and radiologic findings. Non-invasive management, principally device reprogramming, appears to be effective in most patients.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Humanos , Incidência , Resultado do Tratamento
7.
Ann Noninvasive Electrocardiol ; 24(2): e12595, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30265434

RESUMO

Junctional and AV nodal reentrant tachycardia share common electrocardiographic features, but they differ in their management and outcomes after catheter ablation. This case concerns a 60-year-old female who presented with recurrent episodes of a relatively slow, regular supraventricular arrhythmia. Electrocardiographic features of the arrhythmia were discordant regarding its underlying mechanism. However, careful analysis of 12-lead electrocardiograms, with focus on the effect of spontaneous premature beats, pointed out the arrhythmia etiology. Electrophysiological study and pacing maneuvers defined the arrhythmic substrate that was successfully treated by catheter ablation.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Supraventricular/diagnóstico por imagem , Diagnóstico Diferencial , Eletrofisiologia/métodos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
8.
Eur Radiol ; 28(6): 2406-2416, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29318430

RESUMO

OBJECTIVES: To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). METHODS: We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). RESULTS: 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. CONCLUSIONS: A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. KEY POINTS: • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.


Assuntos
Arritmias Cardíacas/terapia , Artefatos , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/normas , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
Artigo em Inglês | MEDLINE | ID: mdl-28008694

RESUMO

Regular narrow QRS tachycardia, particularly if well-tolerated, is usually considered a "benign" arrhythmia of a supraventricular origin. This case concerns an 82-year-old male with ischemic heart disease who presented with recurrent episodes of a narrow QRS tachycardia that was initially diagnosed and treated as atrial tachyarrhythmia. However, careful physical examination and ECG analysis established the correct diagnosis, and the patient was managed appropriately. Remarkably, the observation of irregular cannon A waves, and Lewis lead recording, confirmed atrioventricular dissociation during tachycardia and indicated its underlying mechanism.


Assuntos
Eletrocardiografia/métodos , Bloqueio Cardíaco/complicações , Bloqueio Cardíaco/diagnóstico , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Idoso de 80 Anos ou mais , Cicatriz/complicações , Cicatriz/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino
11.
Artigo em Inglês | MEDLINE | ID: mdl-27440741

RESUMO

Complete left bundle branch block (LBBB) is established according to standard electrocardiographic criteria. However, functional LBBB may be rate-dependent or can perpetuate during tachycardia due to repetitive concealed retrograde penetration of impulses through the contralateral bundle "linking phenomenon." In this brief article, we present two patients with basal complete LBBB in whom ablating the right bundle unmasked the actual antegrade conduction capabilities of the left bundle. These cases highlight intriguing overlap between electrophysiological concepts of complete block, linking, extremely slow, and concealed conduction.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/cirurgia , Ablação por Cateter/métodos , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Resultado do Tratamento
12.
J Electrocardiol ; 50(1): 148-150, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27443783

RESUMO

Ventricular fibrillation is typically the initial arrhythmia in commotio cordis following precordium impacts that occur within an electrically vulnerable period of the cardiac cycle. Conversely, complete heart block is very rare in this context, and its mechanism and temporal course are poorly understood. The presented case concerns a 12-year-old boy, athletic skier, who developed a transient complete heart block following commotio cordis. The electrocardiographic features, the proposed block level and mechanisms of complete heart block following commotio cordis are discussed.


Assuntos
Traumatismos em Atletas/diagnóstico , Commotio Cordis/diagnóstico , Eletrocardiografia/métodos , Bloqueio Cardíaco/diagnóstico , Esqui/lesões , Criança , Diagnóstico Diferencial , Humanos , Masculino
16.
Ann Noninvasive Electrocardiol ; 21(4): 420-4, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26969821

RESUMO

Intravenous adenosine is a short-acting blocker of the atrioventricular node that has been used to unmask subtle or latent preexcitation, and also to enable catheter ablation in selected patients with absent or intermittent preexcitation. Depending on the accessory pathway characteristics, intravenous adenosine may produce specific electrocardiographic changes highly suggestive of the preexcitation variant. Herein, we view different ECG responses to this pharmacological test in various preexcitation patterns that were confirmed by electrophysiological studies. Careful analysis of electrocardiographic changes during adenosine test, with emphasis on P-delta interval, preexcitation degree, and atrioventricular block, can be helpful to diagnose the preexcitation variant/pattern.


Assuntos
Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Eletrocardiografia/métodos , Síndromes de Pré-Excitação/tratamento farmacológico , Síndromes de Pré-Excitação/fisiopatologia , Síndrome de Wolff-Parkinson-White/tratamento farmacológico , Síndrome de Wolff-Parkinson-White/fisiopatologia , Adolescente , Adulto , Ablação por Cateter , Teste de Esforço , Feminino , Humanos , Masculino , Síndrome de Wolff-Parkinson-White/cirurgia
19.
Indian Pacing Electrophysiol J ; 15(4): 220-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937125

RESUMO

A 15-year-old female with WPW syndrome and normal heart underwent an electrophysiology study for paroxysmal palpitations and syncope. Intravenous adenosine produced an unexpected response of QRS changes and advanced AV block. During isoproteronol infusion, short-lasting and poorly tolerated wide QRS tachycardia was inducible, but pacing maneuvers were not feasible during tachycardia to determine its definitive mechanism. However, various electrophysiologic phenomena including adenosine response, junctional beats pattern, and multisite atrial pacing were helpful to overcome the diagnosis challenges. Finally, careful evaluation of tachycardia features and the comprehensive electrophysiology study were crucial to establish presence of unusual preexcitation variants, and thus to guide successful catheter ablation of the arrhythmic substrate.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa