Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36610064

RESUMO

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Punções , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Resultado do Tratamento
2.
Europace ; 22(5): 732-738, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32142124

RESUMO

AIMS: Transseptal puncture (TP) for left atrial (LA) catheter ablation procedures is routinely performed under fluoroscopic guidance. To decrease radiation exposure and increase safety alternative techniques are desirable. The aim of this study was to assess whether right atrial (RA) electroanatomic 3D mapping can reliably identify the fossa ovalis (FO) in preparation of TP. METHODS AND RESULTS: Between May 2019 and August 2019, electroanatomic RA mapping was performed before TP in 61 patients with paroxysmal or persistent atrial fibrillation. Three electroanatomic methods for FO identification, mapping catheter-induced FO protrusion, electroanatomic-guided analysis, and voltage mapping, were evaluated and compared with transoesophageal echocardiography (TOE). Mapping catheter-induced FO protrusion was feasible in 60 patients (98%) with a mean displacement of 6.8 ± 2.5 mm, confirmed by TOE, and proofed to be the most valuable and easiest marker for FO identification. Electroanatomic-guided analysis localized the FO midpoint consistently in the lower half (43 ± 7%) and posterior (18.2 ± 4.4 mm) to a line between coronary sinus and vena cava superior. Analysis of RA voltage maps during sinus rhythm (n = 40, low-voltage cut-off value 1.0 and 1.5 mV) allowed secure FO recognition in 33% and 18%, only. A step-by-step approach, combining FO protrusion (first step) with anatomy criteria in case of protrusion failure (second step) would have allowed for the correct localization of a TP site within the FO in all patients. CONCLUSION: Right atrial electroanatomic 3D mapping prior to TP proofed to be a simple tool for FO identification and may potentially be of use in the safe and radiation-free performance of TP prior to LA ablation procedures.


Assuntos
Fibrilação Atrial , Septo Interatrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Projetos Piloto , Punções , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 21(2): 120-5, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19793145

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Complete PV occlusion during balloon ablation has been shown to predict successful electrical isolation. The aim of this study was to correlate mechanical PV occlusion with changes in a pressure curve recorded at the distal tip of the cryoballoon catheter. METHODS AND RESULTS: We analyzed 51 PVs in 12 patients (61 +/- 6 years old) with paroxysmal AF. At first, PV occlusion via the cryoballoon was documented by changes in the pressure curve. Once the PV is occluded, the pressure curve registered in the vein converts from a left atrial pressure curve to a pulmonary artery pressure curve: the PV wedge curve. Occlusion was then confirmed by transesophageal echocardiography (TEE). Following 2 cryoablation applications, electrical PV isolation was assessed with a circumferential mapping catheter. Under the exclusive guidance of changes in the pressure curve at the tip of the cryoballoon, mechanical occlusion confirmed by TEE was achieved in 47 of 51 PVs (92%). Three PVs required further TEE guidance to achieve occlusion. All 50 occluded veins were electrically isolated after cryoablation. One right inferior vein, which could not be occluded with the balloon, displayed conduction post cryoablation and was isolated by focal ablation. CONCLUSIONS: Occlusion and electrical isolation of PVs during cryoballoon ablation can be predicted by the appearance of a PV wedge curve at the tip of the catheter. This new straightforward parameter may facilitate the procedure.


Assuntos
Fibrilação Atrial/cirurgia , Determinação da Pressão Arterial/métodos , Cateterismo/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Determinação da Pressão Arterial/instrumentação , Cateterismo/instrumentação , Criocirurgia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 20(11): 1197-202, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19563358

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Transesophageal echocardiography (TEE) allows real-time visualization of cryoballoon positioning and successful vein occlusion via color Doppler. We hypothesized that PV mechanical occlusion monitored with TEE could predict effective electrical isolation. METHODS: We studied 124 PVs in 30 patients. Under continuous TEE assessment, a cryoballoon was placed in the antrum of each PV aiming for complete PV occlusion as documented by color Doppler. At the end of the procedure, PV electrical isolation was evaluated using a circumferential mapping catheter. RESULTS: Of the 124 PVs studied, 123 (99.2%) could be visualized by TEE: the antrum was completely visualized in 80 of them (64.5%), partially in 36 (29.0%), and only disappearance of proximal flow could be observed in the remaining 7 PVs (5.7%). Vein occlusion could be achieved in 111 of the 123 (90.2%) visualized PVs. Postinterventional mapping demonstrated electrical isolation in 109 of 111 occluded PVs (positive predictive value 98.2%) and only in 1 of 12 nonoccluded PVs (negative predictive value 91.7%, P < 0.001). After a mean follow-up of 7.4 +/- 3.7 months, 73.3% of patients remained in sinus rhythm without antiarrhythmic drugs. CONCLUSION: Color Doppler documented PV occlusion during cryoballoon ablation can predict effective electrical isolation.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo/métodos , Criocirurgia/métodos , Ecocardiografia Transesofagiana/métodos , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Cateterismo/tendências , Criocirurgia/tendências , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Resultado do Tratamento
6.
Bioorg Med Chem ; 15(2): 903-14, 2007 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-17110115

RESUMO

[(11)C]ABP688 (2) has recently been demonstrated to be a useful PET tracer for in vivo imaging of the metabotropic glutamate receptors type 5 (mGluR5) in rodents. We describe here the identification and preclinical profiling of ABP688 and its tritiated version [(3)H]ABP688, and show that its high affinity (K(d)=2nM), selectivity, and pharmacokinetic properties fulfill all requirements for development as a PET tracer for clinical imaging of the mGlu5 receptor.


Assuntos
Oximas/farmacologia , Oximas/farmacocinética , Piridinas/farmacologia , Piridinas/farmacocinética , Receptores de Ácido Caínico/efeitos dos fármacos , Animais , Autorradiografia , Ligação Competitiva/efeitos dos fármacos , Proteínas Sanguíneas/metabolismo , Linhagem Celular , Fenômenos Químicos , Físico-Química , Cricetinae , Agonistas de Aminoácidos Excitatórios/farmacologia , Humanos , Técnicas In Vitro , Indicadores e Reagentes , Injeções Intravenosas , Ligantes , Masculino , Espectrometria de Massas , Microssomos Hepáticos/efeitos dos fármacos , Microssomos Hepáticos/metabolismo , Fosfatidilinositóis/metabolismo , Tomografia por Emissão de Pósitrons , Ligação Proteica , Ácido Quisquálico/antagonistas & inibidores , Ácido Quisquálico/farmacologia , Compostos Radiofarmacêuticos/síntese química , Ratos , Ratos Sprague-Dawley , Ratos Wistar , Distribuição Tecidual
7.
Bioorg Med Chem Lett ; 12(7): 1099-102, 2002 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-11909726

RESUMO

NMDA antagonists derived from 5-phosphonomethyl-1,4-dihydroquinoxaline-2,3-dione (3a) are potent anticonvulsant agents, and display strong protective effects in the electroshock-induced convulsion assay in mice. Their preference for the human NMDAR 1A/2A over 1A/2B subunit composition was optimized, leading to (1RS,1'S)-PEAQX (9r), which shows a >100-fold selectivity.


Assuntos
Anticonvulsivantes/farmacologia , Quinoxalinas/química , Quinoxalinas/farmacologia , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Animais , Ligação Competitiva , Estimulação Elétrica , Humanos , Camundongos , Estrutura Molecular , Quinoxalinas/síntese química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa