Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
J Nucl Cardiol ; 23(2): 301-10, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26403143

RESUMO

Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Artefatos , Humanos , Processamento de Imagem Assistida por Computador
3.
J Nucl Cardiol ; 21(3): 478-85, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24477404

RESUMO

PURPOSE: We have assessed whether additional upright imaging increases the confidence of interpretation of stress only supine myocardial perfusion imaging (MPI) in obese patients. METHODS AND RESULTS: Tc-MIBI stress MPI of 101 consecutive patients (M = 49, 62 ± 12 years) with BMI ≥30 scanned on the D-SPECT cardiac camera were assessed. Images were interpreted as diagnostic or equivocal and the need for a rest study was recorded. Stress supine MPI was interpreted first, then gated and finally upright data were added. Defects on supine but not on upright were defined as artefacts and defects seen on both as abnormal. The total perfusion deficit (TPD) was also quantified. There were 27 normal, 22 abnormal, and 52 equivocal supine scans. The median EF was 52%, unaffecting the need for rest imaging. Upright imaging reclassified 32/52 (62%) equivocal studies as normal and 6/52 (11%) as abnormal (P < 0.001). Rest scan was deemed needed in 74/101 patients on supine vs 42/101 on supine/upright (P < 0.001). Supine TPD was normal in 53 and supine/upright TPD was normal in 70 patients (P < 0.001). CONCLUSION: Supine stress MPI is inadequate in obese patients. The addition of upright imaging significantly increases the ability to interpret scans as diagnostic and may reduce considerably the need for rest imaging.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imagem de Perfusão do Miocárdio/instrumentação , Obesidade/diagnóstico por imagem , Posicionamento do Paciente/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/complicações , Dobutamina , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Decúbito Dorsal , Vasodilatadores
4.
Nucl Med Commun ; 44(2): 113-114, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36630215
5.
Nucl Med Commun ; 38(5): 407-414, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28379896

RESUMO

INTRODUCTION: The aim of this study was to evaluate the spectrum of skeletal findings on dual-phase fluorine-18-fluoroethylcholine (F-FECH) PET/CT performed during the work-up of patients referred for suspected prostate cancer relapse. MATERIALS AND METHODS: Three hundred F-FECH PET/CT scans were evaluated prospectively. The low-dose CT features of all cases were categorized as isodense, sclerotic, lytic or mixed lytic/sclerotic and maximum standardized uptake value (SUVmax) values were calculated. Findings on F-FECH PET/CT were correlated with Technetium-99m-methylene diphosphonate planar bone scans and serum prostate-specific antigen. RESULTS: Patient age range was 50-90 years (median 71 years) and prostate-specific antigen values were in the range 0.04-372 ng/ml (Roche Modular method). Seventy-two lesions were detected on F-FECH PET/CT in 45 patients, including 31 (43%) in the pelvis, 17 (23%) in the spine (cervical 3, thoracic 8 and lumbar spine 6) and 10 (13%) in the ribs. Evaluation of low-dose CT in combination with PET helped to characterize benign findings in 21 (29%) lesions. The SUVmax for all except one benign lesion ranged from 0.49 to 2.15. In 51 (71%) lesions because of metastatic disease, SUVmax was 0.6-11.6 for those classified as sclerotic on low-dose CT, 0.7-8.58 for lytic lesions, 1.1-7.65 for isodense lesions and 1.27-3.53 for mixed lytic/sclerotic lesions. Of the 56 F-FECH-avid lesions, 21 lesions showed avidity on bone scan [3 (23%) of the 13 isodense lesions, 14 (40%) of the 35 sclerotic lesions, 2 (50%) of the lytic lesions and 2 (50%) of the mixed sclerotic/lytic lesions]. CONCLUSION: F-FECH PET/CT identified bone lesions in 15% of patients with suspected prostate cancer relapse. SUVmax in isolation cannot be used to characterize these lesions as benign or malignant. Minimal overlap of benign and malignant lesions was observed above SUVmax of 2.5. Low-dose CT of PET/CT is a useful tool to aid characterization.


Assuntos
Neoplasias Ósseas/secundário , Colina/análogos & derivados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/metabolismo , Recidiva
7.
Nucl Med Commun ; 35(2): 182-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24152807

RESUMO

OBJECTIVES: The aim of the study was to evaluate the value of single-photon emission computerized tomography/computed tomography (SPECT/CT) in the clinical assessment of painful knee prostheses. MATERIALS AND METHODS: Between 2009 and 2011 we identified 105 patients who had undergone Tc-hydroxydiphosphonate SPECT/CT for painful knee prosthesis. Complete follow-up data were available for 69 patients (50 women and 19 men; mean age, 71 years) with painful knee prostheses (59 total, nine unicompartmental, one patellofemoral) and clinical suspicion of infection or loosening. The imaging test report in conjunction with the clinical data from the patient's notes was used to gauge how useful the test had been in terms of patient management. RESULTS: SPECT/CT confirmed the suspected clinical diagnosis of loosening in nine patients (13%) and of infection in two (2.9%) and identified other causes in 43 patients (62.3%). In 85.5% of patients, SPECT/CT was clinically useful (both positive and negative results), whereas in 14.5% it had no clinical impact on patient management. Revision surgery was performed in 24/69 (34.8%) patients and confirmed the SPECT/CT diagnosis in 21 patients (seven loosening, one infection, two subchondral fractures, two postoperative inflammation and nine patellofemoral osteoarthritis). CONCLUSION: SPECT/CT is a useful tool for the evaluation of painful knee prosthesis in 85.5% of cases and helps in confirming mechanical loosening and in excluding other causes such as infection and patellofemoral osteoarthritis.


Assuntos
Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho/efeitos adversos , Dor/diagnóstico , Dor/etiologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Dor/diagnóstico por imagem , Manejo da Dor
8.
Nucl Med Commun ; 35(8): 839-48, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24769888

RESUMO

BACKGROUND: Bone marrow stem cell (BMSC) therapy for cardiovascular disease has shown considerable preclinical and clinical promise, but there remains a need for mechanistic studies to help bridge the transition from bench to bedside. We have designed a substudy to our REGENERATE-IHD trial (ClinicalTrial.gov Identifier: NCT00747708) to assess the feasibility of a novel imaging technique to detect angiogenesis following BMSC therapy. METHODS AND RESULTS: Nine patients who had been randomized to receive intracoronary injection of G-CSF-mobilized BMSCs or control (serum) were included in this substudy. Patients underwent SPECT imaging using a novel radiolabelled peptide (Tc-NC100692), which has a high affinity for the αvß3 integrin, an angiogenesis-related integrin. This was repeated 4 days after intracoronary injection of BMSCs/control to assess for neoangiogenesis. The imaging study was well tolerated with no adverse effects. Myocardial tracer uptake was detectable at baseline in all nine patients, with no myocardial uptake seen in two control patients used for comparison. Baseline uptake appeared to correlate with baseline ejection fraction but changes with therapy did not reach statistical significance. CONCLUSION: SPECT imaging with a Tc-NC100692 is feasible in patients with heart failure, with baseline activity suggesting persistent angiogenesis in patients with remote myocardial infarction.


Assuntos
Células da Medula Óssea/citologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Isquemia Miocárdica/complicações , Neovascularização Fisiológica , Transplante de Células-Tronco , Doença Crônica , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Pessoa de Meia-Idade , Compostos de Organotecnécio , Peptídeos Cíclicos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
9.
J Nucl Med ; 54(6): 873-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23578996

RESUMO

UNLABELLED: Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients with known or suspected coronary artery disease (CAD); however, it can underestimate the extent of obstructive CAD. Quantification of myocardial perfusion reserve with PET can assist in the diagnosis of multivessel CAD. We evaluated the feasibility of dynamic tomographic SPECT imaging and quantification of a retention index to describe global and regional myocardial perfusion reserve using a dedicated solid-state cardiac camera. METHODS: Ninety-five consecutive patients (64 men and 31 women; median age, 67 y) underwent dynamic SPECT imaging with (99m)Tc-sestamibi at rest and at peak vasodilator stress, followed by standard gated MPI. The dynamic images were reconstructed into 60-70 frames, 3-6 s/frame, using ordered-subsets expectation maximization with 4 iterations and 32 subsets. Factor analysis was used to estimate blood-pool time-activity curves, used as input functions in a 2-compartment kinetic model. K1 values ((99m)Tc-sestamibi uptake) were calculated for the stress and rest images, and K2 values ((99m)Tc-sestamibi washout) were set to zero. Myocardial perfusion reserve (MPR) index was calculated as the ratio of the stress and rest K1 values. Standard MPI was evaluated semiquantitatively, and total perfusion deficit (TPD) of at least 5% was defined as abnormal. RESULTS: Global MPR index was higher in patients with normal MPI (n = 51) than in patients with abnormal MPI (1.61 [interquartile range (IQR), 1.33-2.03] vs. 1.27 [IQR, 1.12-1.61], P = 0.0002). By multivariable regression analysis, global MPR index was associated with global stress TPD, age, and smoking. Regional MPR index was associated with the same variables and with regional stress TPD. Sixteen patients undergoing invasive coronary angiography had 20 vessels with stenosis of at least 50%. The MPR index was 1.11 (IQR, 1.01-1.21) versus 1.30 (IQR, 1.12-1.67) in territories supplied by obstructed and nonobstructed arteries, respectively (P = 0.02). MPR index showed a stepwise reduction with increasing extent of obstructive CAD (P = 0.02). CONCLUSION: Dynamic tomographic imaging and quantification of a retention index describing global and regional perfusion reserve are feasible using a solid-state camera. Preliminary results show that the MPR index is lower in patients with perfusion defects and in regions supplied by obstructed coronary arteries. Further studies are needed to establish the clinical role of this technique as an aid to semiquantitative analysis of MPI.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Cádmio , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Sensibilidade e Especificidade , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Zinco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa