Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38650062

RESUMO

AIMS: The extracardiac conduit-Fontan (ECC) has become the preferred technique for univentricular heart palliation, but there are currently no data on the incidence of long-term arrhythmias. This study investigated the incidence of arrhythmias and relation to single ventricle morphology in the long-term follow-up (FU) in ECC. METHODS AND RESULTS: All patients with ECC performed in our Centre between 1987 and 2017 were included (minimum FU 5 years). Of 353 consecutive patients, 303 [57.8% males, aging 8-50 (median 20) years at last FU] were considered and divided into two groups depending on left (194 in Group 1) or right (109 in Group 2) ventricular morphology. Eighty-five (28%) experienced ≥1 arrhythmic complications, with early and late arrhythmias in 17 (5.6%) and 73 (24.1%) patients, respectively. Notably, late bradyarrhythmias occurred after 6 years in 21 (11%) patients in Group 1, and in 15 (13.8%) in Group 2 [P = 0.48]. Late tachyarrhythmias occurred in 55 (18.2%) patients after 12 years: 33 (17%) in Group 1 and 22 (20.2%) patients in Group 2 [P  = 0.5]. Ventricular tachycardias (VT) were documented after 12.5 years in 14 (7.2%) patients of Group 1 and 15 (13.8%) of Group 2 [P = 0.06] with a higher incidence in Group 2 during the FU [P = 0.005]. CONCLUSION: Extracardiac conduit is related to a significant arrhythmic risk in the long-term FU, higher than previously reported. Bradyarrhythmias occur earlier but are less frequent than tachyarrhythmias. Interestingly, patients with systemic right ventricle have a significantly higher incidence of VT, especially in a very long FU.


Assuntos
Arritmias Cardíacas , Técnica de Fontan , Ventrículos do Coração , Humanos , Masculino , Feminino , Técnica de Fontan/efeitos adversos , Incidência , Criança , Adolescente , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Pessoa de Meia-Idade , Adulto Jovem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/epidemiologia , Estudos Retrospectivos , Fatores de Tempo , Coração Univentricular/cirurgia , Coração Univentricular/epidemiologia , Coração Univentricular/fisiopatologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Fatores de Risco
2.
Eur J Pediatr ; 183(4): 1509-1524, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38236403

RESUMO

Extracorporeal membrane oxygenation (ECMO) is an invasive life support technique that requires a blood pump, an artificial membrane lung, and vascular cannulae to drain de-oxygenated blood, remove carbon dioxide, oxygenate, and return it to the patient. ECMO is generally used to provide advanced and prolonged cardiopulmonary support in patients with refractory acute cardiac and/or respiratory failure. After its first use in 1975 to manage a severe form of meconium aspiration syndrome with resultant pulmonary hypertension, the following years were dominated by the use of ECMO to manage neonatal respiratory failure and limited to a few centers across the world. In the 1990s, evidence for neonatal respiratory ECMO support increased; however, the number of cases began to decline with the use of newer pharmacologic therapies (e.g., inhaled nitric oxide, exogenous surfactant, and high-frequency oscillatory ventilation). On the contrary, pediatric ECMO sustained steady growth. Combined advances in ECMO technology and bedside medical management have improved general outcomes, although ECMO-related complications remain challenging. Point-of-care ultrasound (POCUS) is an essential tool to monitor all phases of neonatal and pediatric ECMO: evaluation of ECMO candidacy, ultrasound-guided ECMO cannulation, daily evaluation of heart and lung function and brain perfusion, detection and management of major complications, and weaning from ECMO support.  Conclusion: Based on these considerations and on the lack of specific guidelines for the use of POCUS in the neonatal and pediatric ECMO setting, the aim of this paper is to provide a systematic overview for the application of POCUS during ECMO support in these populations. What is Known: • Extracorporeal membrane oxygenation (ECMO) provides advanced cardiopulmonary support for patients with refractory acute cardiac and/or respiratory failure and requires appropriate monitoring. • Point-of-care ultrasound (POCUS) is an accessible and adaptable tool to assess neonatal and pediatric cardiac and/or respiratory failure at bedside. What is New: • In this review, we discussed the use of POCUS to monitor and manage at bedside neonatal and pediatric patients supported with ECMO. • We explored the potential use of POCUS during all phases of ECMO support: pre-ECMO assessment, ECMO candidacy evaluation, daily evaluation of heart, lung and brain function, detection and troubleshooting of major complications, and weaning from ECMO support.


Assuntos
Oxigenação por Membrana Extracorpórea , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Recém-Nascido , Lactente , Criança , Ultrassonografia/métodos , Insuficiência Respiratória/terapia , Insuficiência Respiratória/diagnóstico por imagem
3.
Perfusion ; 39(1_suppl): 95S-106S, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651583

RESUMO

Background: Cardiogenic shock in children still carries a high mortality risk despite advances in medical therapy. The use of temporary mechanical circulatory supports is an accepted strategy to bridge patients with acute heart failure to recovery, decision, transplantation or destination therapy. These devices are however limited in children and extracorporeal membrane oxygenation (ECMO) remains the most commonly used device. Veno-arterial ECMO may provide adequate oxygen delivery, but it does not significantly unload the left ventricle, and this may prevent recovery. To improve the likelihood of left ventricular recovery and minimize the invasiveness of mechanical support, the Impella axial pump has been increasingly used in children with acute heart failure in the last decade. Purpose: There are still limited data describing the Impella indications, management and outcomes in children, therefore, we aimed to provide a comprehensive narrative review useful for the pediatric nurses to be adequately trained and acquire specific competencies in Impella management.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico , Criança , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Enfermagem Pediátrica/métodos , Choque Cardiogênico/terapia
4.
Artif Organs ; 47(8): 1319-1325, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36855905

RESUMO

BACKGROUND: Data on the use and outcome of children on ventricular assist device (VAD) support provided with an implantable cardioverter-defibrillator (ICD) remains poor. METHODS: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from January 1, 2009 to April 1, 2020. Patients with missing data on status of ICD, missing baseline and/or follow up information were excluded. The primary independent variable of interest was the concomitant presence or absence of an ICD at the time of VAD placement. Kaplan-Meier survival analysis was performed to evaluate survival differences between children on VAD with and without an ICD. RESULTS: Out of 303 patients provided with a VAD, 7% (7♀, 15♂) had an ICD implanted and formed the study group. Median age was 14 years, median weight was 43.5 kg, and median BSA was 1.39. Median Intermacs stage was 2 (range: 1-7). Seventeen patients (77%) were transplanted, 4 (18%) died while on support, and 1 (5%) was weaned from device after myocardial recovery. Median time on support was 68 days compared to 361 days in the control group (p: 0.01). Three patients underwent device exchange due to thrombus formation in the pump. There was no difference in survival between groups (p = 0.342). CONCLUSION: The presence of ICD in pediatric patients supported with a VAD is low (7%). Children on VAD support provided with an ICD do not have a survival benefit compared to children without an ICD.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Criança , Adolescente , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Sistema de Registros , Resultado do Tratamento
6.
Pediatr Transplant ; 25(2): e13890, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33105518

RESUMO

DCM is the leading cause of death in Duchenne patients. LVADs are considered as therapeutic options as DT in advanced HF. The aim of our study was to evaluate LV remodeling of Duchenne after LVADs and chronic therapy. Demographic and echocardiographic data of 8 Duchenne patients implanted with LVADs were reviewed and analyzed. All measures were collected before LVAD implantation, after 1 month and 1 year. All patients were affected by end-stage DCM, and mean age at implantation was 16.9 ± 2.9 years. Patients were treated with maximal medical therapy. One-year post-implantation HR decreased from a mean of 110 ± 19 bpm to 82 ± 2 bpm (P = .002), and a significant decrease in LV volumes and diameters LVEDD P = .03, LVESD P = .02, EDV P = .01, and ESV P = .02) was noticed together with a significant increase in EF (P = .0036). However, RWT did not change over time, showing an eccentric remodeling pattern pre- and post-LVADs. Our data showed that cardiac atrophy is persistent in Duchenne cardiomyopathy despite the improvement of LV function secondary to a significant ventricular unloading due to LVADs coupled with chronic therapy.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Distrofia Muscular de Duchenne/cirurgia , Miocárdio/patologia , Remodelação Ventricular , Adolescente , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/fisiopatologia , Criança , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Atrofia Muscular , Distrofia Muscular de Duchenne/diagnóstico por imagem , Distrofia Muscular de Duchenne/patologia , Distrofia Muscular de Duchenne/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda
7.
Eur J Pediatr ; 180(6): 1675-1692, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33547504

RESUMO

Neonatal extracorporeal membrane oxygenation (ECMO) is a life-saving procedure for critically ill neonates suffering from a potentially reversible disease, causing severe cardiac and/or respiratory failure and refractory to maximal conventional management. Since the 1970s, technology, management, and clinical applications of neonatal ECMO have changed. Pulmonary diseases still represent the principal neonatal diagnosis, with an overall 74% survival rate, and up to one-third of cases are due to congenital diaphragmatic hernia. The overall survival rate in cardiac ECMO is lower, with congenital heart defect representing the main indication. This review provides an overview of the available evidence in the field of neonatal ECMO. We will address the changing epidemiology, basic principles, technologic advances in circuitry, and monitoring, and deliver a current multidisciplinary management framework, focusing on ECMO applications, complications, and long-term morbidities. Lastly, areas for further research will be highlighted.Conclusions: ECMO is a life support with a potential impact on long-term patients' outcomes. In the next years, advances in knowledge, technology, and expertise may push neonatal ECMO boundaries towards more premature and increasingly complex infants, with the final aim to reduce the burden of ECMO-related complications and improve overall patients' outcomes. What is Known: • ECMO is a life-saving option in newborns with refractory respiratory and/or cardiac failure. • The multidisciplinary ECMO management is challenging and may expose neonates to complications with an impact on long-term outcomes. What is New: • Advances in technology and biomaterials will improve neonatal ECMO management and, eventually, the long-term outcome of these complex patients. • Experimental models of artificial placenta and womb technology are under investigation and may provide clinical translation and future research opportunities.


Assuntos
Oxigenação por Membrana Extracorpórea , Hérnias Diafragmáticas Congênitas , Insuficiência Respiratória , Europa (Continente)/epidemiologia , Hérnias Diafragmáticas Congênitas/terapia , Humanos , Recém-Nascido , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Taxa de Sobrevida
8.
J Card Surg ; 36(3): 798-799, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33503686

RESUMO

En bloc heart-lung transplantation still represents definitive therapy for end-stage cardiopulmonary failure. However, patients may critically decompensate while awaiting suitable donor organs and necessitate veno-arterial extracorporeal membrane oxygenation. In this article, we describe the combined use of central cannulation with the Berlin Heart EXCOR ventricular assist device cannulae and the CentriMag centrifugal pump as an extended bridge to heart-lung transplantation in three pediatric patients.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Transplante de Coração-Pulmão , Cânula , Criança , Insuficiência Cardíaca/terapia , Humanos
9.
Pediatr Cardiol ; 42(5): 1082-1087, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33837838

RESUMO

Warfarin is prescribed in patients with ventricular assist devices (VADs). Dosage depends on several factors including the underlying genotype. These include polymorphisms of genes encoding cytochrome P450 enzymes, the main ones being CYP2C9, VKORC1, and CYP4F2. The objectives of this study were to evaluate the prevalence of CY2CP9 1*2*3*, VKORC1, and CYP4F2 in children with VADs and the time to reach the target international normalized ratio. We performed a retrospective/prospective study in children with VADs. We recorded polymorphisms, disease, type of VAD, ethnicity, age, gender, height, weight, INR values, bleeding, and thromboembolic episodes. Informed consent was obtained. We enrolled 34 children (19 male, 15 female), with a median age of 2 years (range 0.3-17 years) and median weight of 6.9Kg. The Berlin Heart was the most commonly implanted VAD (22/34; 64%), and the most common diagnosis was dilated cardiomyopathy. Statistical analysis confirmed a significant partial correlation with VKORC1 CC (p = 0.019). The CYP2C9*2 CT genotype showed a late rise in target INR values (p = 0.06), while the CYP2C9*2 CC showed a tendency toward an early INR rise (p = 0.024). We provide new information on the contribution of the warfarin polymorphisms in children with VAD implantation. Pharmacogenomic dosing for children using warfarin has the potential to improve clinical care in VAD patients. Patients with the CYP2C9*2 CT genotype may need more time or higher doses to reach target INR, while clinicians may need to be aware of the potential for a rapid rise in INR in patients with the CYP2C9*2 CC genotype.


Assuntos
Anticoagulantes/administração & dosagem , Coração Auxiliar , Varfarina/administração & dosagem , Adolescente , Anticoagulantes/metabolismo , Criança , Pré-Escolar , Sistema Enzimático do Citocromo P-450/genética , Relação Dose-Resposta a Droga , Feminino , Humanos , Lactente , Coeficiente Internacional Normatizado , Masculino , Farmacogenética , Polimorfismo Genético , Estudos Prospectivos , Estudos Retrospectivos , Vitamina K Epóxido Redutases/genética , Varfarina/metabolismo
10.
Pediatr Transplant ; 24(3): e13655, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31985140

RESUMO

The high discard rate of pediatric donor hearts presents a major challenge for children awaiting heart transplantation. Recent literature identifies several factors that contribute to the disparities in pediatric donor heart usage, including regulatory oversight, the absence of guidelines on pediatric donor heart acceptance, and variation among transplant programs. However, a likely additional contributor to this issue are the behavioral factors influencing transplant team decisions in donor offer scenarios, a topic that has not yet been studied in detail. Behavioral economics and decision psychology provide an excellent foundation for investigating decision-making in the pediatric transplant setting, offering key insights into the behavior of transplant professionals. We conducted a systematic review of published literature in pediatric heart transplant related to behavioral economics and the psychology of decision-making. In this review, we draw on paradigms from these two domains in order to examine how existing aspects of the transplant environment, including regulatory oversight, programmatic variation, and allocation systems, may precipitate potential biases surrounding donor offer decisions. Recognizing how human decision behavior influences donor acceptance is a first step toward improving utilization of potentially viable pediatric donor hearts.


Assuntos
Tomada de Decisão Clínica/métodos , Tomada de Decisões , Seleção do Doador/métodos , Economia Comportamental , Transplante de Coração , Adolescente , Viés , Criança , Pré-Escolar , Seleção do Doador/economia , Humanos , Lactente , Recém-Nascido , Risco
11.
Artif Organs ; 43(1): E1-E8, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30398290

RESUMO

Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). For each weight, the sensitivity of the pump to different circulatory parameters (peripheral resistance, left ventricular elastance, right ventricular elastance, heart rate, and heart filling characteristics) has been tested repeating for each experiment a pump ramp (10 000-18 000 rpm). The increase in the pump speed causes a decrease (increase) in the left (right) atrial pressure, an increase (decrease) in the arterial systemic (pulmonary) pressure, an increase in the right ventricular pressure, a decrease (increase) in the left (right) ventricular volume, a decrease in the left ventricular cardiac output, an increase in the LVAD output and an increase in the right ventricular cardiac output (total cardiac output). Suction was observed for lower weight patients and for higher pump speed in the case of vasodilation, left ventricular recovery, bradycardia, right ventricular failure, and left ventricular hypertrophy. Backflow was observed in the case of left ventricular recovery at lower pump speed. In the hybrid simulator, the Infant Jarvik 2015 could be suitable for the implantation in patients lower than 8 kg because of the stability of the device respect to the cardio/circulatory changes (low frequency of suction and backflow) and because of the capability of the device to maintain adequate patient hemodynamics.


Assuntos
Peso Corporal , Coração Auxiliar/normas , Hemodinâmica , Modelos Biológicos , Implantação de Prótese/normas , Estudos de Viabilidade , Humanos , Lactente , Recém-Nascido , Reprodutibilidade dos Testes
12.
Cardiol Young ; 29(8): 1066-1071, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31331409

RESUMO

INTRODUCTION: Some authors advocate the use of a dedicated formula to predict the Fontan pressure starting from pre-Fontan catheterisation data. This paper aims at testing the predictive value of the mentioned formula through a retrospective clinical study. METHODS AND RESULTS: Pre-Fontan catheterisation data and Fontan pressure measured at the completion were retrospectively collected. Pre-Fontan data were used to calculate the predicted pressure in the Fontan system. The predicted values were compared to the Fontan pressure measured at the Fontan completion and with the needs for fenestration. One hundred twenty-four Fontan patients were retrospectively enrolled (At Fontan: median age 30.73 [24.70-37.20] months, median weight 12.00 [10.98-14.15] kg). Fontan conduit was fenestrated in 78 patients. A poor correlation (r2 = 0.05128) between the measured and predicted data for non-fenestrated patients was observed. In the case of Fontan-predicted pressure <17.59 mmHg, the formula identified a good short-term clinical outcome with a sensitivity of 92%. CONCLUSION: The proposed formula showed a poor capability in estimating the actual pressure into the Fontan system and in identifying patients needing fenestration. As the pressure into the Fontan system is determined by multiple factors, the tested formula could be an additional data in a multi-parametric approach.


Assuntos
Técnica de Fontan/métodos , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Pré-Escolar , Feminino , Humanos , Modelos Lineares , Masculino , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Veias Cavas/cirurgia
13.
BMC Med Genet ; 19(1): 170, 2018 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-30219046

RESUMO

BACKGROUND: Loeys-Dietz syndrome (LDS) is a rare multisystemic disorder characterized by vascular and skeletal abnormalities, with considerable intra- and interfamilial variability. CASE PRESENTATION: We report the case of an 8-year-old male with clinical features of two distinct genetic disorders, namely LDS, manifesting in the first months by progressive aortic root dilatation, arterial tortuosity, bifid uvula, and inguinal hernias and oculocutaneous albinism (OCA) manifesting by white hair and skin that does not tan, nystagmus, reduced iris pigment with iris translucency, and reduced retinal pigment). We identified previously reported, homozygous mutations of TYR, c.1A > G (p.Met1Val) and heterozygous, missense mutation of TGFBR1, c.1460G > A (p.Arg487Gln). Family history revealed that his mother underwent multiple surgical repairs for recurrent hemorrhage originating from the buccal artery. Molecular studies confirmed a maternally inherited low grade TGFBR1 mutation somatic mosaicism (18% in peripheral blood leukocytes, 18% in buccal cells and 10% in hair root cells). Maternal cardiac investigations revealed peculiar cardiovascular features: mild tortuosity at the aortic arch, dilatation of the proximal abdominal aorta, multiple deep left ventricular myocardial crypts, and dysplastic mitral valve. TGFBR2 germline mosaicism has been described in three fathers of children carrying TGFBR2 mutations but, to the best of our knowledge, no case of maternally inherited TGFBR1 mutation mosaicism has been reported so far. CONCLUSIONS: This case report suggests that individuals with somatic mosaicism might be at risk for mild and unusual forms of LDS but germline mosaicism can lead to full blown picture of the disease in offspring.


Assuntos
Albinismo Oculocutâneo/genética , Dilatação Patológica/genética , Síndrome de Loeys-Dietz/genética , Herança Materna , Mosaicismo , Receptor do Fator de Crescimento Transformador beta Tipo I/genética , Adulto , Albinismo Oculocutâneo/diagnóstico por imagem , Albinismo Oculocutâneo/patologia , Aorta/diagnóstico por imagem , Aorta/metabolismo , Aorta/patologia , Criança , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/patologia , Feminino , Expressão Gênica , Mutação em Linhagem Germinativa , Humanos , Síndrome de Loeys-Dietz/diagnóstico por imagem , Síndrome de Loeys-Dietz/patologia , Angiografia por Ressonância Magnética , Masculino , Mutação de Sentido Incorreto , Miocárdio/metabolismo , Miocárdio/patologia , Receptor do Fator de Crescimento Transformador beta Tipo I/metabolismo
14.
Artif Organs ; 42(4): 386-393, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29230826

RESUMO

The aim of this study was to describe the echocardiographic trend of left ventricular (LV) and right ventricular (RV) function after implantation of a pulsatile flow left ventricular assist device (LVAD) in children. From 2013 to 2016, we prospectively evaluated 13 consecutive pediatric Berlin Heart EXCOR LVAD patients. Clinical and echocardiographic data were collected at baseline, within 24 h after implantation and monthly until LVAD explant. Median age and weight at the implantation was 8 (4-23) months and 5 (4.6-8.3) kg at the time of implantation, respectively. All were affected by dilated cardiomyopathy. Average LVAD support time was 226.2 ± 121.2 days. Nine (70%) were transplanted, 4 (30%) died. LV end-systolic and end-diastolic volumes were reduced until the follow up of two months (P = 0.019 and P = 0.001). A progressive increase in RV dimensions was observed. After 4 months of follow up, RV fractional area change worsening was statistically related with the deterioration of LV unloading (P = 0.0036). Four patients needed prolonged inotropic support for RV failure. Pulsatile LVAD in pediatrics is followed by an early and mid-term LV unloading, as expressed by a decrease in LV volumes and diameters at echocardiogram. The effects of unloading do not remain stable at long term follow up. RV function improved in the acute phase, but a progressive dilatation of RV was noted over time. In some patients, RV failure might lead to the need of an increase of inotropic support at long term follow up.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/mortalidade , Cardiomiopatia Dilatada/fisiopatologia , Cardiotônicos/uso terapêutico , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Lactente , Masculino , Estudos Prospectivos , Fluxo Pulsátil , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
15.
Artif Organs ; 42(4): 451-456, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29667250

RESUMO

The use of Berlin Heart EXCOR VAD (BH) is a validated therapy to bridge pediatric patients to heart transplant. Serial echocardiographic (ECHO) assessment of VAD patients is necessary to support patients' management. This work aims at developing an innovative strategy to evaluate the BH device functioning by ECHO and its interaction with the native heart in a pediatric population. ECHO evaluation of BH membrane movement, and inflow and outflow valves was performed in 2D, 2D-color Doppler, M-mode, and M-mode color Doppler to assess the functioning of the device by direct positioning of the ECHO probe on the BH cannulas and membranes. Forty Berlin Heart EXCOR VAD were analyzed in 18 patients. Seven BH were placed as RVAD and 33 as LVAD. Results evidenced that 14 (21) inflow (outflow) valves presented a mild regurgitation, while 5 inflow (3 outflow) valves presented a moderate regurgitation. In three cases, we observed severe valve regurgitation with back flow in the left ventricle/right atrium. In both cases, the BH chambers were substituted, but we observed that in one case the regurgitation was due to cannulas compression, while in the other case it was due to valve malfunctioning. The M-mode and the ECHO of the membranes and valves permitted to appreciate the beat phenomenon to assess if the native heart and the BH are working in opposite or in the same phase. The membrane ECHO permits evaluation of minimal changes in membrane movement to assure the completely empty-completely fully work modality. Systematic ECHO assessment of BH chamber might support the BH programming and the detection of anomalous VAD-heart interaction.


Assuntos
Ecocardiografia/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Criança , Átrios do Coração/diagnóstico por imagem , Transplante de Coração , Humanos , Estudos Prospectivos , Resultado do Tratamento
16.
Perfusion ; 33(1_suppl): 24-30, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29788844

RESUMO

INTRODUCTION: Neonatal and pediatric ECMO is a high-risk procedure that should be performed only in expert centers. Children who are eligible for ECMO and are managed in hospitals without ECMO capabilities should be referred to the closest ECMO center before the severity of illness precludes safe conventional transport. When the clinical situation precludes safe conventional transport, ECMO should be provided on site with the patient transported on ECMO. METHODS: We retrospectively reviewed our institutional database of all ECMO transports for neonatal and pediatric respiratory failure from February 2013 to February 2018. RESULTS: Over the last 5 years, we provided 24 transports covering all requests from the center and south of Italy except for the islands. Of these transports, 20 were performed on ECMO and 4 without ECMO. No patient died during transportation. Five complications were reported only during the ECMO transports, and all of these were managed without compromising the patient's safety. The preferred modes of transport were by ambulance (70%) and ambulance transported into the fixed wing aircraft (30%) for longer national distances. The survival to hospital discharge of the patients transported with ECMO was 75% among the neonatal transports and 83.3% among the pediatric transports. The survival to hospital discharge of the four patients transported without ECMO was 100% for both neonates and children. CONCLUSIONS: Neonatal and pediatric ECMO transports can be safely performed with a dedicated team that maintains stringent adherence to well-designed management protocols.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Transporte de Pacientes/métodos , Aeronaves , Ambulâncias , Feminino , Humanos , Lactente , Recém-Nascido , Itália , Masculino , Fatores de Tempo
17.
Artif Organs ; 41(1): 32-39, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28025826

RESUMO

The aim of this work is to develop and test a lumped parameter model of the cardiovascular system to simulate the concurrent use of pulsatile (PVAD) and continuous flow (CVAD) ventricular assist device (VAD) on Fontan patients. Echocardiographic and hemodynamic data of five Fontan patients were retrospectively collected and used to simulate the patients' baseline hemodynamics. Then, for each patient, the following assistance modality was simulated for the cavopulmonary and the single ventricle (SV): (a) CVAD for cavopulmonary assistance (RCF) and PVAD assisting the SV (LCF) (RPF + LCF), (b) CVAD assisting SV and PVAD for cavopulmonary assistance (LPF + RCF). The numerical model can well reproduce patients' baseline. The cardiac output increases more importantly in the LCF + RPF configuration (35 vs. 8%). Ventricular volume decreases more evidently in the configuration LCF + RPF (28 vs. 6%), atrial pressure decreases in the LCF + RPF modality (10%), while it slightly increases in the RCF + LPF modality. The pulmonary arterial pressure slightly decreases (increases) in the configuration RCF + LPF (LCF + RPF). Ventricular external work increases in both configurations because of the total increment of the cardiac output. However, artero-ventricular coupling improves in both configurations: RCF + LPF-14%, LCF + RPF-41%. The pulsatility index decreases (increases) by 8% (13.8%) in the configuration LCF + RPF (RCF + LPF). A model could permit us to simulate extreme physiological conditions of the implantation of both CF and PF VAD on the Fontan patient and could permit to choose the proper VAD on the base of patients' condition. The configuration LCF + RPF seems to maximize the hemodynamic benefits.


Assuntos
Simulação por Computador , Técnica de Fontan , Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Técnica de Fontan/instrumentação , Técnica de Fontan/métodos , Ventrículos do Coração/cirurgia , Humanos , Masculino , Fluxo Pulsátil , Estudos Retrospectivos
18.
Artif Organs ; 41(3): 242-252, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28281287

RESUMO

The aim of this work is to develop and test a lumped parameter model of the cardiovascular system to simulate the simultaneous use of pulsatile (P) and continuous flow (C) ventricular assist devices (VADs) on the same patient. Echocardiographic and hemodynamic data of five pediatric patients undergoing VAD implantation were retrospectively collected and used to simulate the patients' baseline condition with the numerical model. Once the baseline hemodynamic was reproduced for each patient, the following assistance modalities were simulated: (a) CVAD assisting the right ventricle and PVAD assisting the left ventricle (RCF + LPF), (b) CVAD assisting the left ventricle and PVAD assisting the right ventricle (LCF + RPF). The numerical model can well reproduce patients' baseline. The cardiac output increases in both assisted configurations (RCF + LPF: +17%, LCF + RPF: +21%, P = ns), left (right) ventricular volumes decrease more evidently in the configuration LCF + RPF (RCF + LPF), left (right) atrial pressure decreases in the LCF + RPF (RCF + LPF) modality. The pulmonary arterial pressure slightly decreases in the configuration LCF + RPF and it increases with RCF + LPF. Left and right ventricular external work increases in both configurations probably because of the total cardiac output increment. However, left and right artero-ventricular coupling improves especially in the LCF + RPF (-36% for the left ventricle and -21% for the right ventricle, P = ns). The pulsatility index decreases by 8.5% in the configuration LCF + RPF and increases by 6.4% with RCF + LPF (P = 0.0001). A numerical model could be useful to tailor on patients the choice of the VAD that could be implanted to improve the hemodynamic benefits. Moreover, a model could permit to simulate extreme physiological conditions and innovative configurations, as the implantation of both CVAD and PVAD on the same patient.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Modelos Cardiovasculares , Desenho de Prótese , Fluxo Pulsátil , Função Ventricular Esquerda , Função Ventricular Direita , Pré-Escolar , Simulação por Computador , Ecocardiografia , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Lactente , Masculino , Análise Numérica Assistida por Computador , Estudos Retrospectivos
19.
Artif Organs ; 41(12): 1099-1108, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28621816

RESUMO

The aim of this work is to study pediatric pneumatic ventricle (PVAD) performance, versus VAD rate (VADR) and native heart rate (HR) ratio Rr (VADR/HR). The study uses a hybrid model of the cardiovascular system (HCS). HCS consists of a computational part (a lumped parameter model including left and right ventricles, systemic and pulmonary arterial and venous circulation) interfaced to a physical part. This permits the connection of a VAD (15 mL PVAD). Echocardiographic and hemodynamic data of a pediatric patient (average weight 14.3 kg, HR 100 bpm, systemic pressure 75/44 mm Hg, CO 1.5 L/min) assisted apically with asynchronous PVAD were used to set up a basal condition in the model. After model tuning, the assistance was started, setting VAD parameters (ejection and filling pressures, systole duration) to completely fill and empty the PVAD. The study was conducted with constant HR and variable VADR (50-120, step 10, bpm). Experiments were repeated for two additional patients' HRs, 90 and 110 bpm and for two values of systemic arterial resistance (Ras ) and Emax . Experimental data were collected and stored on disk. Analyzed data include average left and right ventricular volumes (LVV, RVV), left ventricular flow (LVF), VAD flow (VADF), and total cardiac output (COt). Data were analyzed versus Rr. LVV and RVV are sensitive to Rr and a left ventricular unloading corresponds in general to a right ventricular loading. In the case of asynchronous assistance, frequency beats are always present and the beat rate is equal to the difference between HR and VADR. In the case of pulsatile asynchronous LVAD assistance, VADR should be chosen to minimize frequency beat effects and right ventricular loading and to maximize left ventricular unloading.


Assuntos
Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Débito Cardíaco , Criança , Desenho de Equipamento , Humanos , Fluxo Pulsátil , Resistência Vascular , Função Ventricular
20.
Artif Organs ; 40(5): 444-53, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26494529

RESUMO

Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy.


Assuntos
Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Hemodinâmica , Adulto , Simulação por Computador , Diástole , Feminino , Técnica de Fontan , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Desenho de Prótese , Implantação de Prótese , Sístole , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa