Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(3): 707-720, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37843600

RESUMO

PURPOSE: New total-body PET scanners with a long axial field of view (LAFOV) allow for higher temporal resolution due to higher sensitivity, which facilitates perfusion estimation by model-free deconvolution. Fundamental tracer kinetic theory predicts that perfusion can be estimated for all tracers despite their different fates given sufficiently high temporal resolution of 1 s or better, bypassing the need for compartment modelling. The aim of this study was to investigate whether brain perfusion could be estimated using model-free Tikhonov generalized deconvolution for five different PET tracers, [15O]H2O, [11C]PIB, [18F]FE-PE2I, [18F]FDG and [18F]FET. To our knowledge, this is the first example of a general model-free approach to estimate cerebral blood flow (CBF) from PET data. METHODS: Twenty-five patients underwent dynamic LAFOV PET scanning (Siemens, Quadra). PET images were reconstructed with an isotropic voxel resolution of 1.65 mm3. Time framing was 40 × 1 s during bolus passage followed by increasing framing up to 60 min. AIF was obtained from the descending aorta. Both voxel- and region-based calculations of perfusion in the thalamus were performed using the Tikhonov method. The residue impulse response function was used to estimate the extraction fraction of tracer leakage across the blood-brain barrier. RESULTS: CBF ranged from 37 to 69 mL blood min-1 100 mL of tissue-1 in the thalamus. Voxelwise calculation of CBF resulted in CBF maps in the physiologically normal range. The extraction fractions of [15O]H2O, [18F]FE-PE2I, [11C]PIB, [18F]FDG and [18F]FET in the thalamus were 0.95, 0.78, 0.62, 0.19 and 0.03, respectively. CONCLUSION: The high temporal resolution and sensitivity associated with LAFOV PET scanners allow for noninvasive perfusion estimation of multiple tracers. The method provides an estimation of the residue impulse response function, from which the fate of the tracer can be studied, including the extraction fraction, influx constant, volume of distribution and transit time distribution, providing detailed physiological insight into normal and pathologic tissue.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Encéfalo/diagnóstico por imagem , Perfusão
2.
Photochem Photobiol Sci ; 23(3): 517-526, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38337129

RESUMO

Squamous cell carcinoma represents the second most common type of keratinocyte carcinoma with ultraviolet radiation (UVR) making up the primary risk factor. Oral photoprotection aims to reduce incidence rates through oral intake of photoprotective compounds. Recently, drug repurposing has gained traction as an interesting source of chemoprevention. Because of their reported photoprotective properties, we investigated the potential of bucillamine, carvedilol, metformin, and phenformin as photoprotective compounds following oral intake in UVR-exposed hairless mice. Tumour development was observed in all groups in response to UVR, with only the positive control (Nicotinamide) demonstrating a reduction in tumour incidence (23.8%). No change in tumour development was observed in the four repurposed drug groups compared to the UV control group, whereas nicotinamide significantly reduced carcinogenesis (P = 0.00012). Metformin treatment significantly reduced UVR-induced erythema (P = 0.012), bucillamine and phenformin increased dorsal pigmentation (P = 0.0013, and P = 0.0005), but no other photoprotective effect was observed across the repurposed groups. This study demonstrates that oral supplementation with bucillamine, carvedilol, metformin, or phenformin does not affect UVR-induced carcinogenesis in hairless mice.


Assuntos
Carcinoma de Células Escamosas , Cisteína/análogos & derivados , Neoplasias Cutâneas , Camundongos , Animais , Raios Ultravioleta , Carvedilol/farmacologia , Camundongos Pelados , Fenformin/farmacologia , Carcinoma de Células Escamosas/prevenção & controle , Carcinoma de Células Escamosas/etiologia , Carcinogênese/efeitos da radiação , Niacinamida/farmacologia , Neoplasias Cutâneas/etiologia , Neoplasias Cutâneas/prevenção & controle , Neoplasias Cutâneas/patologia , Pele/efeitos da radiação
3.
Dermatology ; 240(3): 453-461, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38599196

RESUMO

INTRODUCTION: Ultraviolet radiation (UVR) is the primary risk factor for keratinocyte carcinomas. Oral supplementation with nicotinamide (NAM) is reported to reduce the formation of new keratinocyte carcinomas. NAM's photoprotection is mediated by enhanced DNA repair. We wanted to explore whether NAM in combination with antiproliferative (metformin [Met]) or antioxidant (phloroglucinol [PG]) compounds could potentially enhance its photoprotective effects. METHODS: Hairless mice (C3.Cg-Hrhr/TifBomTac) were treated orally with either a standard dose of NAM monotherapy (NAM-mono; 600 mg/kg) or NAM (400 mg/kg) combined with Met (200 mg/kg) (NAM-Met) or PG (75 mg/kg) (NAM-PG). Mice were irradiated with 3.5 standard erythema doses of UVR three times per week to induce tumour development. Photoprotective effects were based on (i) tumour onset of the first three tumours, (ii) skin photodamage, and (iii) DNA damage (cyclobutane pyrimidine dimers [CPDs] and pyrimidine-pyrimidone (6-4) photoproducts [6-4PPs]). RESULTS: All mice treated with NAM demonstrated a delay in tumour onset and reduced tumour burden compared to the UV control group (NAM, NAM-Met, NAM-PG vs. UV control: p ≤ 0.015). NAM-mono and NAM-PG increased time until all three tumours with no difference between them, indicating a similar degree of photoprotection. NAM-mono had no effect on DNA damage compared to the UV control group (p > 0.05), whereas NAM-PG reduced 6-4PP lesions (p < 0.01) but not CPDs (p > 0.05) compared to NAM-mono. NAM-Met delayed the onset of the third tumour compared to the UV control but demonstrated a quicker onset compared to NAM-mono, suggesting inferior photoprotection compared to nicotinamide monotherapy. CONCLUSION: NAM-PG was as effective in delaying UVR-induced tumour onset as NAM-mono. The reduction in 6-4PP lesions may indicate that the mechanism of NAM-PG is better suited for photoprotection than NAM-mono. NAM-mono was superior to NAM-Met, indicating a dose dependency of NAM's photoprotection. These results highlight the potential for combining photoprotective compounds to enhance photoprotection.


Assuntos
Metformina , Camundongos Pelados , Niacinamida , Neoplasias Cutâneas , Raios Ultravioleta , Animais , Niacinamida/uso terapêutico , Niacinamida/farmacologia , Neoplasias Cutâneas/prevenção & controle , Raios Ultravioleta/efeitos adversos , Camundongos , Metformina/farmacologia , Metformina/uso terapêutico , Neoplasias Induzidas por Radiação/prevenção & controle , Neoplasias Induzidas por Radiação/etiologia , Quimioterapia Combinada , Antioxidantes/farmacologia , Antioxidantes/uso terapêutico , Dano ao DNA/efeitos dos fármacos , Dano ao DNA/efeitos da radiação , Feminino , Complexo Vitamínico B/uso terapêutico , Complexo Vitamínico B/farmacologia
4.
Neuroimage ; 259: 119412, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35753592

RESUMO

PURPOSE: Positron Emission Tomography (PET) can support a diagnosis of neurodegenerative disorder by identifying disease-specific pathologies. Our aim was to investigate the feasibility of using activity reduction in clinical [18F]FE-PE2I and [11C]PiB PET/CT scans, simulating low injected activity or scanning time reduction, in combination with AI-assisted denoising. METHODS: A total of 162 patients with clinically uncertain Alzheimer's disease underwent amyloid [11C]PiB PET/CT and 509 patients referred for clinically uncertain Parkinson's disease underwent dopamine transporter (DAT) [18F]FE-PE2I PET/CT. Simulated low-activity data were obtained by random sampling of 5% of the events from the list-mode file and a 5% time window extraction in the middle of the scan. A three-dimensional convolutional neural network (CNN) was trained to denoise the resulting PET images for each disease cohort. RESULTS: Noise reduction of low-activity PET images was successful for both cohorts using 5% of the original activity with improvement in visual quality and all similarity metrics with respect to the ground-truth images. Clinically relevant metrics extracted from the low-activity images deviated < 2% compared to ground-truth values, which were not significantly changed when extracting the metrics from the denoised images. CONCLUSION: The presented models were based on the same network architecture and proved to be a robust tool for denoising brain PET images with two widely different tracer distributions (delocalized, ([11C]PiB, and highly localized, [18F]FE-PE2I). This broad and robust application makes the presented network a good choice for improving the quality of brain images to the level of the standard-activity images without degrading clinical metric extraction. This will allow for reduced dose or scan time in PET/CT to be implemented clinically.


Assuntos
Aprendizado Profundo , Nortropanos , Doença de Parkinson , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos
5.
Acta Oncol ; 61(2): 239-246, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34533416

RESUMO

INTRODUCTION: The prospective TEDDI protocol investigates the feasibility of radiotherapy delivery in deep inspiration breath-hold (DIBH) for pediatric patients. To secure optimal radiotherapy planning, a diagnostic baseline FDG PET/CT in free breathing (FB) and DIBH was acquired. The anatomical changes in the mediastinum and the effect on PET metrics between the two breathing conditions were assessed for pediatric patients with mediastinal lymphoma. MATERIAL AND METHODS: Ten patients aged 5-17 were included and had a PET/CT in FB and DIBH. Metabolic active lymphoma volumes were manually delineated with a visually based segmentation method and the PET metrics were extracted. The anatomical lymphoma, lung and heart volumes were delineated on CT. RESULTS: The lung volume increased while the heart was displaced caudally and separated from the lymphoma in DIBH compared to FB. Both the anatomical and the metabolically active lymphoma volumes appeared different regarding shape and configuration in the two breathing conditions. The image quality of the DIBH PET was equal to the FB PET regarding interpretation and delineation of lymphoma lesions. All PET metrics increased on the DIBH PET compared to the FB PET with the highest increase observed for the maximum standardized uptake value (33%, range 7-56%). CONCLUSION: Diminished respiratory motion together with anatomical changes within the lymphoma increased all PET metrics in DIBH compared to FB. The anatomical changes observed in DIBH compared to FB are expected to reduce radiation doses to the heart and lungs in pediatric patients with mediastinal lymphoma referred for radiotherapy delivery in DIBH and, thereby, reduce their risk of late effects. TRIAL REGISTRATION: The Danish Ethical Committee (H-16035870, approved November 24th 2016), the Danish Data Protection Agency (2012-58-0004, approved 1 January 2017). Registered retrospectively at clinicaltrials.gov (NCT03315546, 20 October 2017).


Assuntos
Linfoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adolescente , Suspensão da Respiração , Criança , Pré-Escolar , Fluordesoxiglucose F18 , Coração , Humanos , Linfoma/diagnóstico por imagem , Linfoma/radioterapia , Órgãos em Risco/diagnóstico por imagem , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
6.
Acta Oncol ; 60(8): 1045-1053, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34107847

RESUMO

BACKGROUND: Radiotherapy (RT) planning for cervical cancer patients entails the acquisition of both Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Further, molecular imaging by Positron Emission Tomography (PET) could contribute to target volume delineation as well as treatment response monitoring. The objective of this study was to investigate the feasibility of a PET/MRI-only RT planning workflow of patients with cervical cancer. This includes attenuation correction (AC) of MRI hardware and dedicated positioning equipment as well as evaluating MRI-derived synthetic CT (sCT) of the pelvic region for positioning verification and dose calculation to enable a PET/MRI-only setup. MATERIAL AND METHODS: 16 patients underwent PET/MRI using a dedicated RT setup after the routine CT (or PET/CT), including eight pilot patients and eight cervical cancer patients who were subsequently referred for RT. Data from 18 patients with gynecological cancer were added for training a deep convolutional neural network to generate sCT from Dixon MRI. The mean absolute difference between the dose distributions calculated on sCT and a reference CT was measured in the RT target volume and organs at risk. PET AC by sCT and a reference CT were compared in the tumor volume. RESULTS: All patients completed the examination. sCT was inferred for each patient in less than 5 s. The dosimetric analysis of the sCT-based dose planning showed a mean absolute error (MAE) of 0.17 ± 0.12 Gy inside the planning target volumes (PTV). PET images reconstructed with sCT and CT had no significant difference in quantification for all patients. CONCLUSIONS: These results suggest that multiparametric PET/MRI can be successfully integrated as a one-stop-shop in the RT workflow of patients with cervical cancer.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
7.
Neuroimage ; 222: 117221, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-32750498

RESUMO

INTRODUCTION: Robust and reliable attenuation correction (AC) is a prerequisite for accurate quantification of activity concentration. In combined PET/MRI, AC is challenged by the lack of bone signal in the MRI from which the AC maps has to be derived. Deep learning-based image-to-image translation networks present itself as an optimal solution for MRI-derived AC (MR-AC). High robustness and generalizability of these networks are expected to be achieved through large training cohorts. In this study, we implemented an MR-AC method based on deep learning, and investigated how training cohort size, transfer learning, and MR input affected robustness, and subsequently evaluated the method in a clinical setup, with the overall aim to explore if this method could be implemented in clinical routine for PET/MRI examinations. METHODS: A total cohort of 1037 adult subjects from the Siemens Biograph mMR with two different software versions (VB20P and VE11P) was used. The software upgrade included updates to all MRI sequences. The impact of training group size was investigated by training a convolutional neural network (CNN) on an increasing training group size from 10 to 403. The ability to adapt to changes in the input images between software versions were evaluated using transfer learning from a large cohort to a smaller cohort, by varying training group size from 5 to 91 subjects. The impact of MRI sequence was evaluated by training three networks based on the Dixon VIBE sequence (DeepDixon), T1-weighted MPRAGE (DeepT1), and ultra-short echo time (UTE) sequence (DeepUTE). Blinded clinical evaluation relative to the reference low-dose CT (CT-AC) was performed for DeepDixon in 104 independent 2-[18F]fluoro-2-deoxy-d-glucose ([18F]FDG) PET patient studies performed for suspected neurodegenerative disorder using statistical surface projections. RESULTS: Robustness increased with group size in the training data set: 100 subjects were required to reduce the number of outliers compared to a state-of-the-art segmentation-based method, and a cohort >400 subjects further increased robustness in terms of reduced variation and number of outliers. When using transfer learning to adapt to changes in the MRI input, as few as five subjects were sufficient to minimize outliers. Full robustness was achieved at 20 subjects. Comparable robust and accurate results were obtained using all three types of MRI input with a bias below 1% relative to CT-AC in any brain region. The clinical PET evaluation using DeepDixon showed no clinically relevant differences compared to CT-AC. CONCLUSION: Deep learning based AC requires a large training cohort to achieve accurate and robust performance. Using transfer learning, only five subjects were needed to fine-tune the method to large changes to the input images. No clinically relevant differences were found compared to CT-AC, indicating that clinical implementation of our deep learning-based MR-AC method will be feasible across MRI system types using transfer learning and a limited number of subjects.


Assuntos
Encéfalo/patologia , Demência/patologia , Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Adulto , Osso e Ossos/patologia , Estudos de Coortes , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos
8.
Br J Cancer ; 123(1): 46-53, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32382113

RESUMO

BACKGROUND: The purpose of this study is to test if functional multiparametric imaging with 18F-FDG-PET/MRI correlates spatially with immunohistochemical biomarker status within a lesion of head and neck squamous cell carcinoma (HNSCC), and also whether a biopsy with the highest FDG uptake was more likely to have the highest PD-L1 expression or the highest percentage of vital tumour cells (VTC) compared with a random biopsy. METHODS: Thirty-one patients with HNSCC were scanned on an integrated PET/MRI scanner with FDG prior to surgery in this prospective study. Imaging was quantified with SUV, ADC and Ktrans. A 3D-morphometric MRI scan of the specimen was used to co-register the patient and the specimen scans. All specimens were sectioned in consecutive slices, and slices from six different locations were selected randomly from each tumour. Core biopsies were performed to construct TMA blocks for IHC staining with the ten predefined biomarkers. The spatial correlation was assessed with a partial correlation analysis. RESULTS: Twenty-eight patients with a total of 33 lesions were eligible for further analysis. There were significant correlations between the three imaging biomarkers and some of the IHC biomarkers. Moreover, a biopsy taken from the most FDG-avid part of the tumour did not have a statistically significantly higher probability of higher PD-L1 expression or VTC, compared with a random biopsy. CONCLUSION: We found statistically significant correlations between functional imaging parameters and key molecular cancer markers.


Assuntos
Biomarcadores Tumorais/genética , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Idoso , Antígeno B7-H1/genética , Antígeno B7-H1/isolamento & purificação , Biópsia , Feminino , Fluordesoxiglucose F18/uso terapêutico , Humanos , Imuno-Histoquímica/métodos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia
9.
Eur J Nucl Med Mol Imaging ; 46(3): 603-613, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30276440

RESUMO

BACKGROUND: Recurrence in glioblastoma patients often occur close to the original tumour and indicates that the current treatment is inadequate for local tumour control. In this study, we explored the feasibility of using multi-modality imaging at the time of radiotherapy planning. Specifically, we aimed to identify parameters from pre-treatment PET and MRI with potential to predict tumour recurrence. MATERIALS AND METHODS: Sixteen patients were prospectively recruited and treated according to established guidelines. Multi-parametric imaging with 18F-FET PET/CT and 18F-FDG PET/MR including diffusion and dynamic contrast enhanced perfusion MRI were performed before radiotherapy. Correlations between imaging parameters were calculated. Imaging was related to the voxel-wise outcome at the time of tumour recurrence. Within the radiotherapy target, median differences of imaging parameters in recurring and non-recurring voxels were calculated for contrast-enhancing lesion (CEL), non-enhancing lesion (NEL), and normal appearing grey and white matter. Logistic regression models were created to predict the patient-specific probability of recurrence. The most important parameters were identified using standardized model coefficients. RESULTS: Significant median differences between recurring and non-recurring voxels were observed for FDG, FET, fractional anisotropy, mean diffusivity, mean transit time, extra-vascular, extra-cellular blood volume and permeability derived from scans prior to chemo-radiotherapy. Tissue-specific patterns of voxel-wise correlations were observed. The most pronounced correlations were observed for 18F-FDG- and 18F-FET-uptake in CEL and NEL. Voxel-wise modelling of recurrence probability resulted in area under the receiver operating characteristic curve of 0.77 from scans prior to therapy. Overall, FET proved to be the most important parameter for recurrence prediction. CONCLUSION: Multi-parametric imaging before radiotherapy is feasible and significant differences in imaging parameters between recurring and non-recurring voxels were observed. Combining parameters in a logistic regression model enabled patient-specific maps of recurrence probability, where 18F-FET proved to be most important. This strategy could enable risk-adapted radiotherapy planning.


Assuntos
Glioblastoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Estudos de Viabilidade , Feminino , Fluordesoxiglucose F18 , Glioblastoma/radioterapia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Planejamento da Radioterapia Assistida por Computador , Recidiva , Resultado do Tratamento
10.
Contact Dermatitis ; 81(5): 374-377, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31281968

RESUMO

BACKGROUND: Tree moss (Pseudevernia furfuracea [L.] Zopf.), a lichen growing on conifers, is a frequent fragrance sensitizer. Previous studies have shown two subgroups of tree moss-allergic patients: a group sensitized to common allergens of tree and oak moss (Evernia prunastri), and another group sensitized to colophonium-derived allergens, which may contaminate tree moss extract. OBJECTIVES: To report the results of including tree moss extract in the baseline series and discuss the clinical implications. METHODS: Tree moss extract was included in the baseline series and sensitized patients were assessed for concomitant allergy to colophonium and oak moss, and the relevance of these reactions was analyzed. RESULTS: Altogether, 22 of 632 patients (3.5%) had positive reactions to tree moss. Eight patients were sensitized to tree moss only (among fragrance allergens) and 75% had relevant reactions to colophonium. Fourteen patients were sensitized to other fragrance allergens as well and 28.5% had relevant colophonium reactions. CONCLUSIONS: The prevalence of positive tree moss reactions is high enough to justify its inclusion in the baseline series. If tree moss is not included, patients with positive colophonium reactions should be informed of possible (false) cross-reactivity to tree moss to avoid this labeled fragrance allergen.


Assuntos
Alérgenos/efeitos adversos , Ascomicetos/imunologia , Dermatite Alérgica de Contato/etiologia , Odorantes , Testes do Emplastro/métodos , Extratos Vegetais/efeitos adversos , Resinas Vegetais/efeitos adversos , Adolescente , Adulto , Ascomicetos/química , Criança , Reações Cruzadas , Dinamarca/epidemiologia , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Br J Clin Pharmacol ; 84(8): 1719-1728, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29607554

RESUMO

AIMS: To quantify the anti-inflammatory potency of topical corticosteroids and topical calcineurin inhibitors by measuring the contact allergic response to a diphenylcyclopropenone (DPCP) challenge in de novo sensitized human volunteers. METHODS: Two randomized, double-blind, vehicle-controlled studies were performed encompassing 76 volunteers: 29 in the first and 47 in the second study. Topical drugs were applied pre- and/or post-treatment in block designs. The compounds were tested simultaneously under occluded patch tests covering DPCP-induced dermatitis. Inhibitory responses were assessed by visual scoring and measurements of the oedema thickness with ultrasound. RESULTS: When applied both before and after the DPCP challenge, significant anti-inflammatory effects were seen in descending order for tacrolimus 0.1% ointment, clobetasol propionate ointment, betamethasone valerate ointment and hydrocortisone butyrate ointment, while pimecrolimus cream, hydrocortisone ointment and vehicles had no significant effect. Only tacrolimus ointment (P < 0.01) demonstrated a consistent significant pre-treatment inhibitory effect compared with an untreated DPCP control. CONCLUSIONS: This human testing method in which the inflammation of experimentally induced allergic patch test reactions is quantified by objective measurement allows an analysis of the anti-inflammatory potency of not only topical corticosteroids, but also of drugs that have no effect on vasoconstriction. The method allowed comparison of the potencies of four topical corticosteroids and two calcineurin inhibitors.


Assuntos
Anti-Inflamatórios/administração & dosagem , Inibidores de Calcineurina/administração & dosagem , Dermatite Alérgica de Contato/tratamento farmacológico , Fármacos Dermatológicos/administração & dosagem , Glucocorticoides/administração & dosagem , Administração Cutânea , Adulto , Ciclopropanos/administração & dosagem , Ciclopropanos/imunologia , Dermatite Alérgica de Contato/diagnóstico por imagem , Dermatite Alérgica de Contato/imunologia , Método Duplo-Cego , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pomadas/administração & dosagem , Índice de Gravidade de Doença , Pele/irrigação sanguínea , Pele/diagnóstico por imagem , Pele/efeitos dos fármacos , Pele/imunologia , Resultado do Tratamento , Ultrassonografia , Vasoconstrição/efeitos dos fármacos , Adulto Jovem
13.
BMC Dermatol ; 18(1): 2, 2018 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-29415699

RESUMO

BACKGROUND: Topical corticosteroid or corticosteroid/calcipotriol preparations are recommended first-line topical treatments of psoriasis, but a main cause for the lack of efficacy of topical treatments is considered low rates of adherence to topical drugs. Patient support by the use of applications (apps) for smartphones is suggested to improve medical adherence. METHODS/DESIGN: Design: An investigator-initiated, single-center, single-blind, parallel-group, phase-4 clinical superiority randomized controlled trial (RCT). PARTICIPANTS: 134 patients 18 to 75 years of age with mild-to-moderate psoriasis, who are capable of reading English language, own a smartphone, and are candidates for the study drug calcipotriol and betamethasone dipropionate (Cal/BD) cutaneous foam once daily prn (pro re nata). INTERVENTION: A 28-day adherence-supporting app providing compulsory daily treatment reminders that pop-up on the smartphone screen with a short alert sound. The app synchronizes through Bluetooth® to an electronic monitor (EM) attached to the medication canister. The EM contains a chip registering the amount of foam, day and time the patient use the foam dispenser. The information is displayed in a diary that shows the amount of Cal/BD cutaneous foam used and the number of applied treatment sessions. The app has an optional diary with the patient's rating of symptoms. Non-intervention: Use of Cal/BD cutaneous foam and EM without the app. All participants are prescribed Cal/BD cutaneous foam prn for the entire study period. Primary outcome obtained in week 4: rates of adherence measured by patient report, weight of medication canisters, and number of treatment sessions measured by the EM. Secondary outcomes obtained at baseline, weeks 4, 8, and 26: Lattice System Physician's Global Assessment (LS-PGA) and Dermatology Quality of Life Index (DLQI). DISCUSSION: This trial tests of whether an app can improve rates of adherence to a topical antipsoriatic drug. If the app improves rates of adherence and reduces the burden of psoriasis in a clinically significant way, the app could easily be implemented as a standard routine of care in the clinic. TRIAL REGISTRATION: NCT02858713 , registered on August 3, 2016. EudraCT number 2016-002143-42.


Assuntos
Betametasona/análogos & derivados , Calcitriol/análogos & derivados , Fármacos Dermatológicos/administração & dosagem , Adesão à Medicação , Aplicativos Móveis , Psoríase/tratamento farmacológico , Administração Tópica , Betametasona/administração & dosagem , Calcitriol/administração & dosagem , Humanos , Método Simples-Cego
14.
Contact Dermatitis ; 78(5): 335-340, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29392743

RESUMO

BACKGROUND: Concern about causing active sensitization when patch testing is performed with p-phenylenediamine (PPD) 1% pet. has led to a recommendation to use PPD 0.3% pet. as a potentially safer preparation. However, the dose per area of allergen delivered, and hence the risk of active sensitization, depend on the amount dispensed into the patch test chamber, which can vary widely. OBJECTIVE: To evaluate whether patch testing with equivalent doses of different concentrations of PPD in pet. is associated with similar outcomes. METHODS: Seventeen known PPD-sensitive subjects were patch tested with different volumes and concentrations of PPD in pet. that deliver the same allergen dose per unit area (6 mg of PPD 1% pet. and 20 mg of PPD 0.3% pet. in Finn Chambers®, both equivalent to ∼ 0.09 mg/cm2 ). RESULTS: Eleven patients (65%) had positive reactions to both doses; 4 patients (24%) had negative results [percentage agreement of 88% (15/17)]. One patient each had a positive reaction to only one dose. CONCLUSIONS: The 88% concordance suggests that dose per unit area is more important in determining reactions to allergens than the excipient volume dispensed. Patch testing with a smaller volume of 1% PPD may be a reasonable alternative to testing with 20 mg of 0.3% PPD.


Assuntos
Corantes/administração & dosagem , Testes do Emplastro/métodos , Fenilenodiaminas/administração & dosagem , Alérgenos/administração & dosagem , Alérgenos/efeitos adversos , Corantes/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico por imagem , Relação Dose-Resposta Imunológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro/efeitos adversos , Vaselina , Fenilenodiaminas/efeitos adversos , Projetos Piloto , Estudos Prospectivos
15.
Neuroimage ; 147: 346-359, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-27988322

RESUMO

AIM: To accurately quantify the radioactivity concentration measured by PET, emission data need to be corrected for photon attenuation; however, the MRI signal cannot easily be converted into attenuation values, making attenuation correction (AC) in PET/MRI challenging. In order to further improve the current vendor-implemented MR-AC methods for absolute quantification, a number of prototype methods have been proposed in the literature. These can be categorized into three types: template/atlas-based, segmentation-based, and reconstruction-based. These proposed methods in general demonstrated improvements compared to vendor-implemented AC, and many studies report deviations in PET uptake after AC of only a few percent from a gold standard CT-AC. Using a unified quantitative evaluation with identical metrics, subject cohort, and common CT-based reference, the aims of this study were to evaluate a selection of novel methods proposed in the literature, and identify the ones suitable for clinical use. METHODS: In total, 11 AC methods were evaluated: two vendor-implemented (MR-ACDIXON and MR-ACUTE), five based on template/atlas information (MR-ACSEGBONE (Koesters et al., 2016), MR-ACONTARIO (Anazodo et al., 2014), MR-ACBOSTON (Izquierdo-Garcia et al., 2014), MR-ACUCL (Burgos et al., 2014), and MR-ACMAXPROB (Merida et al., 2015)), one based on simultaneous reconstruction of attenuation and emission (MR-ACMLAA (Benoit et al., 2015)), and three based on image-segmentation (MR-ACMUNICH (Cabello et al., 2015), MR-ACCAR-RiDR (Juttukonda et al., 2015), and MR-ACRESOLUTE (Ladefoged et al., 2015)). We selected 359 subjects who were scanned using one of the following radiotracers: [18F]FDG (210), [11C]PiB (51), and [18F]florbetapir (98). The comparison to AC with a gold standard CT was performed both globally and regionally, with a special focus on robustness and outlier analysis. RESULTS: The average performance in PET tracer uptake was within ±5% of CT for all of the proposed methods, with the average±SD global percentage bias in PET FDG uptake for each method being: MR-ACDIXON (-11.3±3.5)%, MR-ACUTE (-5.7±2.0)%, MR-ACONTARIO (-4.3±3.6)%, MR-ACMUNICH (3.7±2.1)%, MR-ACMLAA (-1.9±2.6)%, MR-ACSEGBONE (-1.7±3.6)%, MR-ACUCL (0.8±1.2)%, MR-ACCAR-RiDR (-0.4±1.9)%, MR-ACMAXPROB (-0.4±1.6)%, MR-ACBOSTON (-0.3±1.8)%, and MR-ACRESOLUTE (0.3±1.7)%, ordered by average bias. The overall best performing methods (MR-ACBOSTON, MR-ACMAXPROB, MR-ACRESOLUTE and MR-ACUCL, ordered alphabetically) showed regional average errors within ±3% of PET with CT-AC in all regions of the brain with FDG, and the same four methods, as well as MR-ACCAR-RiDR, showed that for 95% of the patients, 95% of brain voxels had an uptake that deviated by less than 15% from the reference. Comparable performance was obtained with PiB and florbetapir. CONCLUSIONS: All of the proposed novel methods have an average global performance within likely acceptable limits (±5% of CT-based reference), and the main difference among the methods was found in the robustness, outlier analysis, and clinical feasibility. Overall, the best performing methods were MR-ACBOSTON, MR-ACMAXPROB, MR-ACRESOLUTE and MR-ACUCL, ordered alphabetically. These methods all minimized the number of outliers, standard deviation, and average global and local error. The methods MR-ACMUNICH and MR-ACCAR-RiDR were both within acceptable quantitative limits, so these methods should be considered if processing time is a factor. The method MR-ACSEGBONE also demonstrates promising results, and performs well within the likely acceptable quantitative limits. For clinical routine scans where processing time can be a key factor, this vendor-provided solution currently outperforms most methods. With the performance of the methods presented here, it may be concluded that the challenge of improving the accuracy of MR-AC in adult brains with normal anatomy has been solved to a quantitatively acceptable degree, which is smaller than the quantification reproducibility in PET imaging.


Assuntos
Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Demência/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos , Adulto Jovem
16.
Exp Dermatol ; 26(10): 926-933, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28370374

RESUMO

The gene expression time-course of repeated challenge of contact allergy (CA) remains largely unknown. Therefore, using diphenylcyclopropenone (DPCP) as model allergen in healthy humans we set out to examine: (i) the monotonous and complex gene expression time-course trajectories following repeated DPCP challenges to find the predominant gene expression pattern, (ii) the time-course of cell infiltration following repeated DPCP challenges and (iii) the transcriptome of a repeated CA exposure model. We obtained punch biopsies from control and DPCP-exposed skin from ten DPCP sensitized individuals at 5-6 monthly elicitation challenges. Biopsies were used for microarray gene expression profiling, histopathology and immunohistochemical staining. Validation of microarray data by qRT-PCR was performed on 15 selected genes. Early gene expression time points were also validated in an independent data set. An increasing and decreasing trend in gene expression followed by a plateau was predominantly observed during repeated DPCP challenges. Immune responses reached a plateau after two challenges histopathologically, immunohistochemically and in the time-course gene expression analysis. Transcriptional responses over time revealed a Th1/Th17 polarization as three upstream regulators (IFN-γ, IL-1 and IL-17) activated most of the top upregulated genes. Of the latter genes, 9 of 10 were the same throughout the time course. Excellent correlations between array and PCR data were observed. The transcriptional responses to DPCP over time followed a monotonous pattern. This response pattern confirms and supports the newly reported clinical time-course observations in de novo-sensitized individuals showing a plateau response, and thus, there is concordance between clinical response, histopathology, immunohistochemistry and microarray gene expression in volunteers de novo-sensitized to DPCP.


Assuntos
Dermatite Alérgica de Contato/genética , Dermatite Alérgica de Contato/imunologia , Expressão Gênica , Pele/metabolismo , Transcriptoma , Adulto , Biópsia , Ciclopropanos , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/patologia , Feminino , Perfilação da Expressão Gênica , Voluntários Saudáveis , Humanos , Interferon gama/metabolismo , Interleucina-1/metabolismo , Interleucina-17/metabolismo , Masculino , Análise de Sequência com Séries de Oligonucleotídeos , Reação em Cadeia da Polimerase em Tempo Real , Pele/patologia , Células Th1/imunologia , Células Th17/imunologia , Fatores de Tempo , Adulto Jovem
18.
Contact Dermatitis ; 76(5): 280-286, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28194806

RESUMO

BACKGROUND: The Australian cushion bush (Leucophyta brownii) of the Compositae family of plants has become a popular pot and container plant. The plant produces the sesquiterpene lactone allergen calocephalin. OBJECTIVES: To assess the sensitizing potential of sesquiterpene lactones from cushion bush. PATIENTS/MATERIALS/METHODS: Eleven Compositae-sensitive patients were patch tested with seven sesquiterpene lactones isolated from cushion bush. RESULTS: Six of seven sesquiterpene lactones elicited positive reactions in 4 of 11 patients. CONCLUSIONS: The well-known sesquiterpene lactone pseudoivalin and its derivative pseudoivalin acetate, as well as calocephalin and tomentosin, were confirmed to be sensitizers, whereas leucophytalin A and 4α-hydroxy-5αH,10αH-1,11(13)-guaidien-8ß,12-olide were shown to be allergenic for the first time. The patch test reaction patterns seem to follow the chemical patterns, which may eventually make it possible to trace primary sensitizers and advise patients more precisely.


Assuntos
Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Extratos Vegetais/efeitos adversos , Sesquiterpenos de Guaiano/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Feminino , Humanos , Masculino , Testes do Emplastro/métodos
19.
Acta Oncol ; 54(1): 60-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25025999

RESUMO

BACKGROUND: Long-term Hodgkin lymphoma (HL) survivors have an increased risk of late cardiac morbidity and secondary lung cancer after chemotherapy and mediastinal radiotherapy. In this prospective study we investigate whether radiotherapy with deep inspiration breath-hold (DIBH) can reduce radiation doses to the lungs, heart, and cardiac structures without compromising the target dose. PATIENTS AND METHODS: Twenty-two patients (14 female, 8 male), median age 30 years (18-65 years), with supra-diaphragmatic HL were enrolled and had a thoracic PET/CT with DIBH in addition to staging FDG-PET/CT in free breathing (FB) and a planning CT in both FB and DIBH. For each patient an involved-node radiotherapy plan was done for both DIBH and FB, and the doses to the lungs, heart, and female breasts were recorded prospectively. Mean doses to the heart valves and coronary arteries were recorded retrospectively. Patients were treated with the technique yielding the lowest doses to normal structures. RESULTS: Nineteen patients were treated with DIBH and three with FB. DIBH reduced the mean estimated lung dose by 2.0 Gy (median: 8.5 Gy vs. 7.2 Gy) (p < 0.01) and the mean heart dose by 1.4 Gy (6.0 Gy vs. 3.9 Gy) (p < 0.01) compared to FB. The lung and heart V20Gy were reduced with a median of 5.3% and 6.3%. Mean doses to the female breasts were equal with FB and DIBH. CONCLUSION: DIBH can significantly decrease the estimated mean doses to the heart and lungs without lowering the dose to the target in radiotherapy for patients with mediastinal HL.


Assuntos
Suspensão da Respiração , Coração/efeitos da radiação , Doença de Hodgkin/radioterapia , Inalação , Pulmão/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Lesões por Radiação/prevenção & controle , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Mama/efeitos da radiação , Feminino , Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Doses de Radiação , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto Jovem
20.
Contact Dermatitis ; 72(2): 75-83, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25395354

RESUMO

BACKGROUND: Oak moss absolute, an extract from the lichen Evernia prunastri, is a valued perfume ingredient but contains extreme allergens. OBJECTIVES: To compare the elicitation properties of two preparations of oak moss absolute: 'classic oak moss', the historically used preparation, and 'new oak moss', with reduced contents of the major allergens atranol and chloroatranol. PATIENTS/MATERIALS/METHODS: The two preparations were compared in randomized double-blinded repeated open application tests and serial dilution patch tests in 30 oak moss-sensitive volunteers and 30 non-allergic control subjects. RESULTS: In both test models, new oak moss elicited significantly less allergic contact dermatitis in oak moss-sensitive subjects than classic oak moss. The control subjects did not react to either of the preparations. CONCLUSIONS: New oak moss is still a fragrance allergen, but elicits less allergic contact dermatitis in previously oak moss-sensitized individuals, suggesting that new oak moss is less allergenic to non-sensitized individuals.


Assuntos
Alérgenos , Benzaldeídos , Dermatite Alérgica de Contato/diagnóstico , Testes do Emplastro/métodos , Perfumes/química , Resinas Vegetais , Terpenos , Alérgenos/administração & dosagem , Benzaldeídos/administração & dosagem , Dermatite Alérgica de Contato/etiologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfumes/efeitos adversos , Resinas Vegetais/administração & dosagem , Resinas Vegetais/efeitos adversos , Resinas Vegetais/química , Medição de Risco , Terpenos/administração & dosagem , Terpenos/efeitos adversos , Terpenos/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa