1.
Ultrason Imaging ; 46(1): 56-70, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37981826

RESUMO

This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.


Assuntos
Tecido Adiposo , Manguito Rotador , Humanos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Reprodutibilidade dos Testes , Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia
2.
Sensors (Basel) ; 23(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37430678

RESUMO

Ultrasound (US) is an important imaging tool for skeletal muscle analysis. The advantages of US include point-of-care access, real-time imaging, cost-effectiveness, and absence of ionizing radiation. However, US can be highly dependent on the operator and/or US system, and a portion of the potentially useful information carried by raw sonographic data is discarded in image formation for routine qualitative US. Quantitative ultrasound (QUS) methods provide analysis of the raw or post-processed data, revealing additional information about normal tissue structure and disease status. There are four QUS categories that can be used on muscle and are important to review. First, quantitative data derived from B-mode images can help determine the macrostructural anatomy and microstructural morphology of muscle tissues. Second, US elastography can provide information about muscle elasticity or stiffness through strain elastography or shear wave elastography (SWE). Strain elastography measures the induced tissue strain caused either by internal or external compression by tracking tissue displacement with detectable speckle in B-mode images of the examined tissue. SWE measures the speed of induced shear waves traveling through the tissue to estimate the tissue elasticity. These shear waves may be produced using external mechanical vibrations or internal "push pulse" ultrasound stimuli. Third, raw radiofrequency signal analyses provide estimates of fundamental tissue parameters, such as the speed of sound, attenuation coefficient, and backscatter coefficient, which correspond to information about muscle tissue microstructure and composition. Lastly, envelope statistical analyses apply various probability distributions to estimate the number density of scatterers and quantify coherent to incoherent signals, thus providing information about microstructural properties of muscle tissue. This review will examine these QUS techniques, published results on QUS evaluation of skeletal muscles, and the strengths and limitations of QUS in skeletal muscle analysis.


Assuntos
Compressão de Dados , Técnicas de Imagem por Elasticidade , Ultrassonografia , Músculo Esquelético/diagnóstico por imagem , Frequência Cardíaca
3.
Radiology ; 304(1): 75-82, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35348378

RESUMO

Background MRI-derived proton density fat fraction (PDFF) is an accurate, reliable, and safe biologic marker for use in the noninvasive diagnosis of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD). Because of the cost and limited availability of MRI, it is necessary to develop an accurate method to diagnose NAFLD with potential point-of-care access. Purpose To compare the diagnostic accuracy of the quantitative US (QUS) fat fraction (FF) estimator with that of the controlled attenuation parameter (CAP) in the diagnosis of NAFLD using contemporaneous MRI-derived PDFF as the reference standard. Materials and Methods Participants with or suspected of having NAFLD were prospectively recruited at the NAFLD Research Center between July 2015 and July 2019. All participants underwent MRI-derived PDFF measurement, transient elastography with CAP measurement, and QUS. QUS FF was derived using computed QUS parameters from the acquired radiofrequency US data using a calibrated reference phantom. The area under the receiver operating characteristic curve (AUC) was calculated to assess the accuracy of QUS FF and CAP in the diagnosis of hepatic steatosis (defined as MRI-derived PDFF ≥ 5%). AUCs were compared using the DeLong test. Results A total of 123 participants were included (mean age, 52 years ± 13 [SD]; 67 [54%] women). Of these participants, 100 (81%) had MRI-derived PDFF of 5% or more. QUS FF had a significantly higher AUC for diagnosis of NAFLD than did CAP (0.92 [95% CI: 0.87, 0.98] vs 0.79 [95% CI: 0.67, 0.90], P = .03). QUS FF had a sensitivity of 98% (98 of 100) and a specificity of 48% (11 of 23). CAP had a sensitivity of 87% (87 of 100) and a specificity of 57% (13 of 23). Conclusion The quantitative US fat fraction estimator is more accurate than the controlled attenuation parameter in the diagnosis of hepatic steatosis in patients with or suspected of having nonalcoholic fatty liver disease. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ito in this issue.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Prótons , Padrões de Referência
4.
Eur Radiol ; 32(4): 2457-2469, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34854929

RESUMO

OBJECTIVES: To compare the diagnostic accuracy of US shear wave elastography (SWE) and magnetic resonance elastography (MRE) for classifying fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD). METHODS: Patients from a prospective single-center cohort with clinical liver biopsy for known or suspected NAFLD underwent contemporaneous SWE and MRE. AUCs for classifying biopsy-determined liver fibrosis stages ≥ 1, ≥ 2, ≥ 3, and = 4, and their respective performance parameters at cutoffs providing ≥ 90% sensitivity or specificity were compared between SWE and MRE. RESULTS: In total, 100 patients (mean age, 51.8 ± 12.9 years; 46% males; mean BMI 31.6 ± 4.7 kg/m2) with fibrosis stage distribution (stage 0/1/2/3/4) of 43, 36, 5, 10, and 6%, respectively, were included. AUCs (and 95% CIs) for SWE and MRE were 0.65 (0.54-0.76) and 0.81 (0.72-0.89), 0.81 (0.71-0.91) and 0.94 (0.89-1.00), 0.85 (0.74-0.96) and 0.95 (0.89-1.00), and 0.91 (0.79-1.00) and 0.92 (0.83-1.00), for detecting fibrosis stage ≥ 1, ≥ 2, ≥ 3, and = 4, respectively. The differences were significant for detecting fibrosis stage ≥ 1 and ≥ 2 (p < 0.01) but not otherwise. At ≥ 90% sensitivity cutoff, MRE yielded higher specificity than SWE at diagnosing fibrosis stage ≥ 1, ≥ 2, and ≥ 3. At ≥ 90% specificity cutoff, MRE yielded higher sensitivity than SWE at diagnosing fibrosis stage ≥ 1 and ≥ 2. CONCLUSIONS: In adults with NAFLD, MRE was more accurate than SWE in diagnosing stage ≥ 1 and ≥ 2 fibrosis, but not stage ≥ 3 or 4 fibrosis. KEY POINTS: • For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography. • For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy. • For excluding advanced fibrosis and potentially ruling out the need for biopsy, SWE and MRE did not differ significantly in negative predictive value. • Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Adulto , Biópsia , Feminino , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos
5.
Radiology ; 295(2): 342-350, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32096706

RESUMO

Background Radiofrequency ultrasound data from the liver contain rich information about liver microstructure and composition. Deep learning might exploit such information to assess nonalcoholic fatty liver disease (NAFLD). Purpose To develop and evaluate deep learning algorithms that use radiofrequency data for NAFLD assessment, with MRI-derived proton density fat fraction (PDFF) as the reference. Materials and Methods A HIPAA-compliant secondary analysis of a single-center prospective study was performed for adult participants with NAFLD and control participants without liver disease. Participants in the parent study were recruited between February 2012 and March 2014 and underwent same-day US and MRI of the liver. Participants were randomly divided into an equal number of training and test groups. The training group was used to develop two algorithms via cross-validation: a classifier to diagnose NAFLD (MRI PDFF ≥ 5%) and a fat fraction estimator to predict MRI PDFF. Both algorithms used one-dimensional convolutional neural networks. The test group was used to evaluate the classifier for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy and to evaluate the estimator for correlation, bias, limits of agreements, and linearity between predicted fat fraction and MRI PDFF. Results A total of 204 participants were analyzed, 140 had NAFLD (mean age, 52 years ± 14 [standard deviation]; 82 women) and 64 were control participants (mean age, 46 years ± 21; 42 women). In the test group, the classifier provided 96% (95% confidence interval [CI]: 90%, 99%) (98 of 102) accuracy for NAFLD diagnosis (sensitivity, 97% [95% CI: 90%, 100%], 68 of 70; specificity, 94% [95% CI: 79%, 99%], 30 of 32; positive predictive value, 97% [95% CI: 90%, 99%], 68 of 70; negative predictive value, 94% [95% CI: 79%, 98%], 30 of 32). The estimator-predicted fat fraction correlated with MRI PDFF (Pearson r = 0.85). The mean bias was 0.8% (P = .08), and 95% limits of agreement were -7.6% to 9.1%. The predicted fat fraction was linear with an MRI PDFF of 18% or less (r = 0.89, slope = 1.1, intercept = 1.3) and nonlinear with an MRI PDFF greater than 18%. Conclusion Deep learning algorithms using radiofrequency ultrasound data are accurate for diagnosis of nonalcoholic fatty liver disease and hepatic fat fraction quantification when other causes of steatosis are excluded. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Lockhart and Smith in this issue.


Assuntos
Redes Neurais de Computação , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Ondas de Rádio , Distribuição Aleatória , Sensibilidade e Especificidade
6.
Radiology ; 295(1): 106-113, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32013792

RESUMO

Background Advanced confounder-corrected chemical shift-encoded MRI-derived proton density fat fraction (PDFF) is a leading parameter for fat fraction quantification in nonalcoholic fatty liver disease (NAFLD). Because of the limited availability of this MRI technique, there is a need to develop and validate alternative parameters to assess liver fat. Purpose To assess relationship of quantitative US parameters to MRI PDFF and to develop multivariable quantitative US models to detect hepatic steatosis and quantify hepatic fat. Materials and Methods Adults with known NAFLD or who were suspected of having NAFLD were prospectively recruited between August 2015 and February 2019. Participants underwent quantitative US and chemical shift-encoded MRI liver examinations. Liver biopsies were performed if clinically indicated. The correlation between seven quantitative US parameters and MRI PDFF was evaluated. By using leave-one-out cross validation, two quantitative US multivariable models were evaluated: a classifier to differentiate participants with NAFLD versus participants without NAFLD and a fat fraction estimator. Classifier performance was summarized by area under the receiver operating characteristic curve and area under the precision-recall curve. Fat fraction estimator performance was evaluated by correlation, linearity, and bias. Results Included were 102 participants (mean age, 52 years ± 13 [standard deviation]; 53 women), 78 with NAFLD (MRI PDFF ≥ 5%). A two-variable classifier yielded a cross-validated area under the receiver operating characteristic curve of 0.89 (95% confidence interval: 0.82, 0.96) and an area under the precision-recall curve of 0.96 (95% confidence interval: 0.93, 0.99). The cross-validated fat fraction predicted by a two-variable fat fraction estimator was correlated with MRI PDFF (Spearman ρ = 0.82 [P < .001]; Pearson r = 0.76 [P < .001]). The mean bias was 0.02% (P = .97), and 95% limits of agreement were ±12.0%. The predicted fat fraction was linear with MRI PDFF (R 2 = 0.63; slope, 0.69; intercept, 4.3%) for MRI PDFF of 34% or less. Conclusion A multivariable quantitative US approach yielded excellent correlation with MRI proton density fat fraction for hepatic steatosis assessment in nonalcoholic fatty liver disease. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia/métodos
7.
J Magn Reson Imaging ; 51(1): 25-42, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30859677

RESUMO

Liver fibrosis is a histological hallmark of most chronic liver diseases, which can progress to cirrhosis and liver failure, and predisposes to hepatocellular carcinoma. Accurate diagnosis of liver fibrosis is necessary for prognosis, risk stratification, and treatment decision-making. Liver biopsy, the reference standard for assessing liver fibrosis, is invasive, costly, and impractical for surveillance and treatment response monitoring. Elastography offers a noninvasive, objective, and quantitative alternative to liver biopsy. This article discusses the need for noninvasive assessment of liver fibrosis and reviews the comparative advantages and limitations of ultrasound and magnetic resonance elastography techniques with respect to their basic concepts, acquisition, processing, and diagnostic performance. Variations in clinical contexts of use and common pitfalls associated with each technique are considered. In addition, current challenges and future directions to improve the diagnostic accuracy and clinical utility of elastography techniques are discussed. Level of Evidence: 5 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:25-42.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Humanos , Fígado/diagnóstico por imagem
8.
Eur Radiol ; 29(9): 4699-4708, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30783789

RESUMO

OBJECTIVES: To assess inter-platform reproducibility of ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) estimates in adults with known/suspected nonalcoholic fatty liver disease (NAFLD). METHODS: This HIPAA-compliant prospective study was approved by an institutional review board; informed consent was obtained. Participants with known/suspected NAFLD were recruited and underwent same-day liver examinations with clinical ultrasound scanner platforms from two manufacturers. Each participant was scanned by the same trained sonographer who performed multiple data acquisitions in the right liver lobe using a lateral intercostal approach. Each data acquisition recorded a B-mode image and the underlying radio frequency (RF) data. AC and BSC were calculated using the reference phantom method. Inter-platform reproducibility was evaluated for AC and log-transformed BSC (logBSC = 10log10BSC) by intraclass correlation coefficient (ICC), Pearson's correlation, Bland-Altman analysis with computation of limits of agreement (LOAs), and within-subject coefficient of variation (wCV; applicable to AC). RESULTS: Sixty-four participants were enrolled. Mean AC values measured using the two platforms were 0.90 ± 0.13 and 0.94 ± 0.15 dB/cm/MHz while mean logBSC values were - 30.6 ± 5.0 and - 27.9 ± 5.6 dB, respectively. Inter-platform ICC was 0.77 for AC and 0.70 for log-transformed BSC in terms of absolute agreement. Pearson's correlation coefficient was 0.81 for AC and 0.80 for logBSC. Ninety-five percent LOAs were - 0.21 to 0.13 dB/cm/MHz for AC, and - 9.48 to 3.98 dB for logBSC. The wCV was 7% for AC. CONCLUSIONS: Hepatic AC and BSC are reproducible across two different ultrasound platforms in adults with known or suspected NAFLD. KEY POINTS: • Ultrasonic attenuation coefficient and backscatter coefficient are reproducible between two different ultrasound platforms in adults with NAFLD. • This inter-platform reproducibility may qualify quantitative ultrasound biomarkers for generalized clinical application in patients with suspected/known NAFLD.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
9.
Eur Radiol ; 28(12): 4992-5000, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29869170

RESUMO

OBJECTIVES: To assess inter-sonographer reproducibility of ultrasound attenuation coefficient (AC), backscatter coefficient (BSC) and shear wave speed (SWS) in adults with known/suspected non-alcoholic fatty liver disease (NAFLD). METHODS: The institutional review board approved this HIPAA-compliant prospective study; informed consent was obtained. Participants with known/suspected NAFLD were recruited and underwent same-day liver examinations with a clinical scanner. Each participant was scanned by two of the six trained sonographers. Each sonographer performed multiple data acquisitions in the right liver lobe using a lateral intercostal approach. A data acquisition was a single operator button press that recorded a B-mode image, radio-frequency data, and the SWS value. AC and BSC were calculated from the radio-frequency data using the reference phantom method. SWS was calculated automatically using product software. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wCV) were calculated for applicable metrics. RESULTS: Sixty-one participants were recruited. Inter-sonographer ICC was 0.86 (95% confidence interval: 0.77-0.92) for AC and 0.87 (0.78-0.92) for log-transformed BSC (logBSC = 10log10BSC) using one acquisition per sonographer. ICC was 0.88 (0.80-0.93) for both AC and logBSC averaging 5 acquisitions. ICC for SWS was 0.57 (0.29-0.74) using one acquisition per sonographer, and 0.84 (0.66-0.93) using 10 acquisitions. The wCV was ~7% for AC, and 19-43% for SWS, depending on number of acquisitions. CONCLUSIONS: Hepatic AC, BSC and SWS measures on a clinical scanner have good inter-sonographer reproducibility in adults with known or suspected NAFLD. Multiple acquisitions are required for SWS but not AC or BSC to achieve good inter-sonographer reproducibility. KEY POINTS: • AC, BSC and SWS measurements are reproducible in adults with NAFLD. • Inter-sonographer reproducibility of SWS measurement improves with more acquisitions being averaged. • Multiple acquisitions are required for SWS but not AC or BSC.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/normas , Adulto , Análise de Variância , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Software
10.
J Ultrasound Med ; 37(8): 1913-1927, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29359454

RESUMO

OBJECTIVES: To assess the repeatability and reproducibility of the ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) measured in the livers of adults with known or suspected nonalcoholic fatty liver disease (NAFLD). METHODS: The Institutional Review Board approved this Health Insurance Portability and Accountability Act-compliant prospective study; informed consent was obtained. Forty-one research participants with known or suspected NAFLD were recruited and underwent same-day ultrasound examinations of the right liver lobe with a clinical scanner by a clinical sonographer. Each participant underwent 2 scanning trials, with participant repositioning between trials. Two transducers were used in each trial. For each transducer, machine settings were optimized by the sonographer but then kept constant while 3 data acquisitions were obtained from the liver without participant repositioning and then from an external calibrated phantom. Raw RF echo data were recorded. The AC and BSC were measured within 2.6 to 3.0 MHz from a user-defined hepatic field of interest from each acquisition. The repeatability and reproducibility were analyzed by random-effects models. RESULTS: The mean AC and log-transformed BSC (logBSC) were 0.94 dB/cm-MHz and -27.0 dB, respectively. Intraclass correlation coefficients were 0.88 to 0.94 for the AC and 0.87 to 0.95 for the logBSC acquired without participant repositioning. For between-trial repeated scans with participant repositioning, the intraclass correlation coefficients were 0.80 to 0.84 for the AC and 0.69 to 0.82 for the logBSC after averaging results from 3 within-trial images. The variability introduced by the transducer was less than the repeatability error. CONCLUSIONS: Hepatic AC and BSC measures using a reference phantom technique on a clinical scanner are repeatable and reproducible between transducers in adults with known or suspected NAFLD.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Ultrason Imaging ; 40(2): 84-96, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28945169

RESUMO

There are two well-known ultrasonic approaches to extract sets of quantitative parameters: Lizzi-Feleppa (LF) parameters: slope, intercept, and midband; and quantitative ultrasound (QUS)-derived parameters: effective scatterer diameter (ESD) and effective acoustic concentration (EAC). In this study, the relation between the LF and QUS-derived parameters is studied theoretically and experimentally on ex vivo mouse livers. As expected from the theory, LF slope is correlated to ESD ([Formula: see text]), and from experimental data, LF midband is correlated to EAC ([Formula: see text]). However, LF intercept is not correlated to ESD ([Formula: see text]) nor EAC ([Formula: see text]). The unexpected correlation observed between LF slope and EAC ([Formula: see text]) results likely from the high correlation between ESD and EAC due to the inversion process. For a liver fat percentage estimation, an important potential medical application, the parameters presenting the better correlation are EAC ([Formula: see text]) and LF midband ([Formula: see text]).


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Fígado/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Estudos de Avaliação como Assunto , Camundongos , Camundongos Endogâmicos C57BL
12.
Hepatology ; 63(2): 453-61, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26560734

RESUMO

UNLABELLED: Magnetic resonance elastography (MRE), an advanced magnetic resonance-based imaging technique, and acoustic radiation force impulse (ARFI), an ultrasound-based imaging technique, are accurate for diagnosing nonalcoholic fatty liver disease (NAFLD) fibrosis. However, no head-to-head comparisons between MRE and ARFI for diagnosing NAFLD fibrosis have been performed. We compared MRE versus ARFI head-to-head for diagnosing fibrosis in well-characterized patients with biopsy-proven NAFLD. This cross-sectional analysis of a prospective cohort involved 125 patients (54.4% female) who underwent MRE, ARFI, and contemporaneous liver biopsies scored using the Nonalcoholic Steatohepatitis Clinical Research Network histological scoring system. The performances of MRE versus ARFI for diagnosing fibrosis were evaluated using area under the receiver operating characteristic curves (AUROCs). The mean (± standard deviation) age and body mass index were 48.9 (±15.4) years and 31.8 (±7.0) kg/m(2) , respectively. For diagnosing any fibrosis (≥ stage 1), the MRE AUROC was 0.799 (95% confidence interval [CI] 0.723-0.875), significantly (P = 0.012) higher than the ARFI AUROC of 0.664 (95% CI 0.568-0.760). In stratified analysis by presence or absence of obesity, MRE was superior to ARFI for diagnosing any fibrosis in obese patients (P < 0.001) but not in nonobese patients (P = 0.722). The MRE AUROCs for diagnosing ≥stages 2, 3, and 4 fibrosis were 0.885 (95% CI 0.816-0.953), 0.934 (95% CI 0.863-1.000), and 0.882 (95% CI 0.729-1.000); and the ARFI AUROCs were 0.848 (95% CI 0.776-0.921), 0.896 (95% CI 0.824-0.968), and 0.862 (95% CI 0.721-1.000). MRE had higher AUROCs than ARFI for discriminating dichotomized fibrosis stages at all dichotomization cutoff points, but the AUROC differences decreased as the cutoff points (fibrosis stages) increased. CONCLUSION: MRE is more accurate than ARFI for diagnosing any fibrosis in NAFLD patients, especially those who are obese.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Adulto , Biópsia , Estudos Transversais , Feminino , Humanos , Cirrose Hepática/etiologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos
13.
AJR Am J Roentgenol ; 208(5): W168-W177, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28267360

RESUMO

OBJECTIVE: The purpose of this study is to explore the diagnostic performance of two investigational quantitative ultrasound (QUS) parameters, attenuation coefficient and backscatter coefficient, in comparison with conventional ultrasound (CUS) and MRI-estimated proton density fat fraction (PDFF) for predicting histology-confirmed steatosis grade in adults with nonalcoholic fatty liver disease (NAFLD). SUBJECTS AND METHODS: In this prospectively designed pilot study, 61 adults with histology-confirmed NAFLD were enrolled from September 2012 to February 2014. Subjects underwent QUS, CUS, and MRI examinations within 100 days of clinical-care liver biopsy. QUS parameters (attenuation coefficient and backscatter coefficient) were estimated using a reference phantom technique by two analysts independently. Three-point ordinal CUS scores intended to predict steatosis grade (1, 2, or 3) were generated independently by two radiologists on the basis of QUS features. PDFF was estimated using an advanced chemical shift-based MRI technique. Using histologic examination as the reference standard, ROC analysis was performed. Optimal attenuation coefficient, backscatter coefficient, and PDFF cutoff thresholds were identified, and the accuracy of attenuation coefficient, backscatter coefficient, PDFF, and CUS to predict steatosis grade was determined. Interobserver agreement for attenuation coefficient, backscatter coefficient, and CUS was analyzed. RESULTS: CUS had 51.7% grading accuracy. The raw and cross-validated steatosis grading accuracies were 61.7% and 55.0%, respectively, for attenuation coefficient, 68.3% and 68.3% for backscatter coefficient, and 76.7% and 71.3% for MRI-estimated PDFF. Interobserver agreements were 53.3% for CUS (κ = 0.61), 90.0% for attenuation coefficient (κ = 0.87), and 71.7% for backscatter coefficient (κ = 0.82) (p < 0.0001 for all). CONCLUSION: Preliminary observations suggest that QUS parameters may be more accurate and provide higher interobserver agreement than CUS for predicting hepatic steatosis grade in patients with NAFLD.


Assuntos
Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Biópsia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Imagens de Fantasmas , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos
14.
AJR Am J Roentgenol ; 207(4): 745-754, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27440524

RESUMO

OBJECTIVE: The purposes of this article are to review available data regarding the range of protection devices and garments with a focus on eye protection and to summarize techniques for reducing scatter radiation exposure. CONCLUSION: Fluoroscopy operators and staff can greatly reduce their radiation exposure by wearing properly fitted protective garments, positioning protective devices to block scatter radiation, and adhering to good radiation practices. By understanding the essentials of radiation physics, protective equipment, and the features of each imaging system, operators and staff can capitalize on opportunities for radiation protection while minimizing ergonomic strain. Practicing and promoting a culture of radiation safety can help fluoroscopy operators and staff enjoy long, productive careers helping patients.


Assuntos
Fluoroscopia/instrumentação , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Gestão da Segurança , Humanos , Doses de Radiação , Medição de Risco , Estados Unidos
15.
AJR Am J Roentgenol ; 207(4): 737-744, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28829623

RESUMO

OBJECTIVE: Recent articles discussing cases of brain cancer in interventionalists have raised concerns regarding the hazards of occupational exposure to ionizing radiation. We review the basics of radiation dose and the potential radiation effects, particularly as they pertain to the operator. Then we present the data regarding the risk of each type of radiation effect to the fluoroscopy operator and staff, with special attention on cancer induction, radiation-induced cataracts, and the pregnant operator. CONCLUSION: Although the evidence overwhelmingly shows that exposure to higher doses of radiation carries a risk of cancer and tissue reactions, the risks of chronic exposure to low-level radiation are less clear. Many studies examining occupational exposure to radiation fail to show an increased risk of stochastic effects of radiation, but the positive results raise concern that the studies are underpowered to consistently detect the small risk. The lack of information in these studies about radiation doses and adherence to radiation protection further confound their interpretation. Large prospective studies of populations with occupational exposure to low-level radiation might clarify this issue. More clearly established are the risks of radiation to the fetus and the risk of cataracts in interventional cardiologists and interventional radiologists. Interventionalists can mitigate these risks by following established radiation safety practices.


Assuntos
Fluoroscopia/instrumentação , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Gestão da Segurança , Humanos , Doses de Radiação , Medição de Risco , Estados Unidos
16.
Clin Gastroenterol Hepatol ; 13(7): 1337-1345.e6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25478922

RESUMO

BACKGROUND & AIMS: Liver biopsy analysis is the standard method used to diagnose nonalcoholic fatty liver disease (NAFLD). Advanced magnetic resonance imaging is a noninvasive procedure that can accurately diagnose and quantify steatosis, but is expensive. Conventional ultrasound is more accessible but identifies steatosis with low levels of sensitivity, specificity, and quantitative accuracy, and results vary among technicians. A new quantitative ultrasound (QUS) technique can identify steatosis in animal models. We assessed the accuracy of QUS in the diagnosis and quantification of hepatic steatosis, comparing findings with those from magnetic resonance imaging proton density fat fraction (MRI-PDFF) analysis as a reference. METHODS: We performed a prospective, cross-sectional analysis of a cohort of adults (N = 204) with NAFLD (MRI-PDFF, ≥5%) and without NAFLD (controls). Subjects underwent MRI-PDFF and QUS analyses of the liver on the same day at the University of California, San Diego, from February 2012 through March 2014. QUS parameters and backscatter coefficient (BSC) values were calculated. Patients were assigned randomly to training (n = 102; mean age, 51 ± 17 y; mean body mass index, 31 ± 7 kg/m(2)) and validation (n = 102; mean age, 49 ± 17 y; body mass index, 30 ± 6 kg/m(2)) groups; 69% of patients in each group had NAFLD. RESULTS: BSC (range, 0.00005-0.25 1/cm-sr) correlated with MRI-PDFF (Spearman ρ = 0.80; P < .0001). In the training group, the BSC analysis identified patients with NAFLD with an area under the curve value of 0.98 (95% confidence interval, 0.95-1.00; P < .0001). The optimal BSC cut-off value identified patients with NAFLD in the training and validation groups with 93% and 87% sensitivity, 97% and 91% specificity, 86% and 76% negative predictive values, and 99% and 95% positive predictive values, respectively. CONCLUSIONS: QUS measurements of BSC can accurately diagnose and quantify hepatic steatosis, based on a cross-sectional analysis that used MRI-PDFF as the reference. With further validation, QUS could be an inexpensive, widely available method to screen the general or at-risk population for NAFLD.


Assuntos
Fígado Gorduroso/diagnóstico , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , California , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia
17.
AJR Am J Roentgenol ; 202(2): 329-35, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24450673

RESUMO

OBJECTIVE: The purpose of this study was to retrospectively assess the potential benefits of delayed phase imaging series in routine CT scans of the abdomen and pelvis. MATERIALS AND METHODS: Routine contrast-enhanced abdominopelvic CT scans of 1000 consecutively examined patients (912 men, 88 women; average age, 60 years; range, 22-94 years) were retrospectively evaluated, and the added benefits of the delayed phase series through the abdomen were recorded for each examination. Examinations performed for indications requiring multiphasic imaging were excluded. Images were reviewed by two fellowship-trained abdominal radiologists, who were blinded to official CT reports. All examinations were performed between July 2008 and February 2010 at a single institution. Radiation doses for both the portal venous and delayed phases, when available, were analyzed to assess the effect of the delayed phase on overall radiation exposure. RESULTS: Forty-two patients (4.2%) had findings that were further characterized or were observed only in the delayed phase. Most were incidental findings that could have been confirmed at noninvasive follow-up imaging, such as sonography or unenhanced CT or MRI. The most common findings were liver hemangioma (n = 12), adrenal adenoma (n = 12), and parapelvic renal cysts (n = 6). The most important finding was detection of a renal mass in one patient (0.1%). The mass was seen only on the delayed phase images but was difficult to appreciate in the portal venous phase. In the other 958 patients (95.8%), delayed imaging was of no benefit. In addition, use of the delayed phase resulted in a mean 59.5% increase in effective radiation dose. CONCLUSION: An additional delayed phase through the abdomen in routine contrast-enhanced CT examinations of the abdomen and pelvis is of low yield, particularly if reliable follow-up imaging to further elucidate uncertain findings is available.


Assuntos
Pelve/diagnóstico por imagem , Doses de Radiação , Radiografia Abdominal/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Iohexol , Masculino , Pessoa de Meia-Idade , Radiografia Abdominal/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X/efeitos adversos , Ácidos Tri-Iodobenzoicos
18.
Ultrasound Med Biol ; 50(8): 1287-1291, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38724329

RESUMO

OBJECTIVE: To compare the effectiveness of positive pressure (PP) and negative pressure (NP) for reducing gas inclusions in biological tissues in preparation for acoustic imaging. METHODS: Eighteen pieces of porcine liver in degassed saline were included in this study. For the PP group (n = 9 samples), a wristwatch waterproof tester was used to pressurize samples to 0.41 MPa (59 psi) for 10 min. For the NP group (n = 9 samples), a desiccator at -0.08 MPa (-12 psi) was used for 30 min. Backscatter coefficients (BSCs) were calculated over the central frequency range of the backscattered spectra and paired-samples t-tests were performed. RESULTS: Utilization of PP resulted in a decrease in BSC for all samples, indicating less gas post-PP (pre-PP -13.0 ± 4.3 dB [mean ± SD], post-PP -18.9 ± 5.0 dB, p = .001). Utilization of NP resulted in an increase in BSC for the majority of samples (pre-NP -14.6 ± 6.0 dB, post-NP -13.1 ± 5.3 dB, p = .177). CONCLUSION: Utilization of a simple PP chamber consistently resulted in a decrease in tissue gas, at lower pressures than previously reported. The vacuum method is ineffective, may result in a paradoxical increase in tissue gas, and may not be recommended for tissue degassing.


Assuntos
Fígado , Pressão , Animais , Suínos , Fígado/diagnóstico por imagem , Ultrassonografia/métodos , Vácuo , Gases
19.
Eur Radiol Exp ; 8(1): 21, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38316687

RESUMO

BACKGROUND: We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient (α), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). METHODS: SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (µCT) at 9-µm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. RESULTS: α demonstrated significant positive Spearman correlations with E (R = 0.69) and BMD (R = 0.44) while showing significant negative correlations with porosity (R = -0.41), T2-MM (R = -0.47), TWPD (R = -0.68), BWPD (R = -0.67), and PWPD (R = -0.45). CONCLUSIONS: The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. RELEVANCE STATEMENT: This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. KEY POINTS: • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.


Assuntos
Osso e Ossos , Prótons , Animais , Bovinos , Microtomografia por Raio-X , Osso e Ossos/diagnóstico por imagem , Osso Cortical/diagnóstico por imagem , Água
20.
Ultrasound Med Biol ; 49(1): 122-135, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36283940

RESUMO

Ultrasound (US) is an increasingly prevalent and effective diagnostic modality for neuromuscular imaging. Gray-scale B-mode imaging has been the dominant US approach to evaluating nerves qualitatively or making morphometric measurements of nerves, providing important insights into pathological changes for conditions such as carpal tunnel syndrome. Among more recent ultrasound strategies, high-frequency ultrasound (often defined as >15 MHz for clinical applications), quantitative ultrasound and image textural analysis offer promising enhancements for improved and more objective approaches to nerve imaging. In this study, we evaluated the repeatability and reproducibility of backscatter coefficient (BSC) and imaging texture features extracted by gray-level co-occurrence matrices (GLCMs) in homogeneous tissue-mimicking reference phantoms and in median nerves in the wrists of healthy participants. We also investigated several practical sources of variability in the assessment of quantitative parameters, including influences of operators, and participant-to-participant variability. Overall, BSC- and GLCM-based outcomes are highly repeatable and reproducible after operator training, based on measurement of descriptive statistics, repeatability coefficient (RC) and reproducibility coefficient recommended by Quantitative Imaging Biomarker Alliance (QIBA RDC). GLCM parameters appear more reproducible and repeatable than BSC-based parameters in healthy participants in vivo. However, such variability noted here must be compared with the value ranges and variability of the results in pathological nerves, including median nerves afflicted by trauma, overuse syndromes such as carpal tunnel syndrome and after surgical repair.


Assuntos
Síndrome do Túnel Carpal , Nervo Mediano , Humanos , Nervo Mediano/diagnóstico por imagem , Reprodutibilidade dos Testes , Síndrome do Túnel Carpal/diagnóstico por imagem , Ultrassonografia/métodos , Imagens de Fantasmas