1.
Magn Reson Med ; 82(6): 2236-2247, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31317566

RESUMO

PURPOSE: The noise navigator is a passive way to detect physiological motion occurring in a patient through thermal noise modulations measured by standard clinical radiofrequency receive coils. The aim is to gain a deeper understanding of the potential and applications of physiologically induced thermal noise modulations. METHODS: Numerical electromagnetic simulations and MR measurements were performed to investigate the relative contribution of tissue displacement versus modulation of the dielectric lung properties over the respiratory cycle, the impact of coil diameter and position with respect to the body. Furthermore, the spatial motion sensitivity of specific noise covariance matrix elements of a receive array was investigated. RESULTS: The influence of dielectric lung property variations on the noise variance is negligible compared to tissue displacement. Coil size affected the thermal noise variance modulation, but the location of the coil with respect to the body had a larger impact. The modulation depth of a 15 cm diameter stationary coil approximately 3 cm away from the chest (i.e. radiotherapy setup) was 39.7% compared to 4.2% for a coil of the same size on the chest, moving along with respiratory motion. A combination of particular noise covariance matrix elements creates a specific spatial sensitivity for motion. CONCLUSIONS: The insight gained on the physical relations governing the noise navigator will allow for optimized use and development of new applications. An optimized combination of elements from the noise covariance matrix offer new ways of performing, e.g. motion tracking.


Assuntos
Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento (Física) , Simulação por Computador , Radiação Eletromagnética , Voluntários Saudáveis , Humanos , Masculino , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Ondas de Rádio , Radioterapia , Razão Sinal-Ruído , Pele/diagnóstico por imagem
2.
Magn Reson Med ; 79(3): 1730-1735, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28593709

RESUMO

PURPOSE: Tracking of the internal anatomy by means of a motion model that uses the MR-derived motion fields and noise covariance matrix (NCM) dynamic as a surrogate signal. METHODS: A 2D respiratory motion model was developed based on the MR-derived motion fields and the NCM of a receive array used in MRI. Temporal dynamics of the NCM were used as a motion surrogate for a linear correspondence motion model. The model performance was tested on five healthy volunteers with a liver as the target. The motion fields were calculated from the cineMR frames with an optical flow registration tool. RESULTS: The model estimated the liver motion with an average residual error of 2.3 mm (13% of the motion amplitude). The model formation takes 3 min and the model latency was 0.5 s in the current implementation. The limiting factor for the latency is the current update time of the NCM (0.48 s), which in principle can be reduced to 0.004 s with an alternative way to determine the NCM. CONCLUSIONS: The 2D respiratory motion of the liver can be effectively estimated with the linear motion model that uses the temporal behavior of the NCM as motion surrogate. Magn Reson Med 79:1730-1735, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Respiração , Algoritmos , Humanos , Fígado/diagnóstico por imagem
3.
Magn Reson Med ; 77(1): 221-228, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26762855

RESUMO

PURPOSE: Development of a passive respiratory motion sensor based on the noise variance of the receive coil array. METHODS: Respiratory motion alters the body resistance. The noise variance of an RF coil depends on the body resistance and, thus, is also modulated by respiration. For the noise variance monitoring, the noise samples were acquired without and with MR signal excitation on clinical 1.5/3 T MR scanners. The performance of the noise sensor was compared with the respiratory bellow and with the diaphragm displacement visible on MR images. Several breathing patterns were tested. RESULTS: The noise variance demonstrated a periodic, temporal modulation that was synchronized with the respiratory bellow signal. The modulation depth of the noise variance resulting from the respiration varied between the channels of the array and depended on the channel's location with respect to the body. The noise sensor combined with MR acquisition was able to detect the respiratory motion for every k-space read-out line. CONCLUSION: Within clinical MR systems, the respiratory motion can be detected by the noise in receive array. The noise sensor does not require careful positioning unlike the bellow, any additional hardware, and/or MR acquisition. Magn Reson Med 77:221-228, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Respiração , Processamento de Sinais Assistido por Computador , Algoritmos , Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Humanos , Ondas de Rádio , Razão Sinal-Ruído
4.
Magn Reson Med ; 71(4): 1641-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23788130

RESUMO

PURPOSE: Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilitates RF shimming based on the traveling waves. METHODS: The multimode, coaxial waveguide combines the coaxial waveguide, cylindrical waveguide, high dielectric permittivity lining, and eight radial stub antennas. Each antenna excites multiple waveguide modes. Based on modes orthogonality, a method was devised to decompose an excitation pattern of single stub antenna into waveguide modes. RESULTS: The number of modes present in the excitation pattern of a single stub antenna increased with the higher effective permittivity of the dielectric lining. Thus, RF shimming performance of the setup was improved. An average homogeneity of 10% was demonstrated for a single slice of each principle plane in the human head at 7 T. CONCLUSION: Traveling wave RF shimming is feasible both in axial and longitudinal directions and is improved with an increased amount of orthogonal waveguide modes. Nevertheless, with the currently available RF amplifiers at 7 T, the performance of the setup is limited to low flip angles.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Campos Magnéticos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
5.
Magn Reson Med ; 70(3): 885-94, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23044511

RESUMO

Application of travelling wave MR to human body imaging is restricted by the limited peak power of the available RF amplifiers. Nevertheless, travelling wave MR advantages like a large field of view excitation and distant location of transmit elements would be desirable for whole body MRI. In this work, improvement of the B1+ efficiency of travelling wave MR is demonstrated. High permittivity dielectric lining placed next to the scanner bore wall effectively reduces attenuation of the travelling wave in the longitudinal direction and at the same time directs the radial power flow toward the load. First, this is shown with an analytical model of a metallic cylindrical waveguide with the dielectric lining next to the wall and loaded with a cylindrical phantom. Simulations and experiments also reveal an increase of B1+ efficiency in the center of the bore for travelling wave MR with a dielectric lining. Phantom experiments show up to a 2-fold gain in B1+ with the dielectric lining. This corresponds to a 4-fold increase in power efficiency of travelling wave MR. In vivo experiments demonstrate an 8-fold signal-to-noise ratio gain with the dielectric lining. Overall, it is shown that dielectric lining is a constructive method to improve efficacy of travelling wave MR.


Assuntos
Imageamento por Ressonância Magnética/métodos , Humanos , Modelos Teóricos , Imagens de Fantasmas
6.
Magn Reson Med ; 69(4): 1186-93, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22760686

RESUMO

A setup for 7T MRI of the carotid arteries in the neck was designed and constructed. Separate dedicated arrays were used for transmit and receive. For the transmit array, single-side adapted dipole antennas were mounted on a dielectric pillow, which was shown to serve as a leaky waveguide, efficiently distributing B1 into the neck. Risk assessment was performed by simulations. Phantom measurements were performed to establish optimal positions of the antennas on the pillow. Using two antennas, a dual transmit setup was created. In vivo B1 (+) maps with different shim configurations were acquired to assess transmit performance. This effective transmit array was used in combination with a dedicated 30 channel small element receive coil. High-resolution in vivo turbo spin echo images were acquired to demonstrate the excellent performance of the setup.


Assuntos
Artérias Carótidas/anatomia & histologia , Aumento da Imagem/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
NMR Biomed ; 26(11): 1596-601, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23893556

RESUMO

A method to measure the T2 relaxation time of GABA with spectral editing techniques is proposed. Spectral editing techniques can be used to unambiguously extract signals of low concentration J-coupled spins such as γ-aminobutyric acid (GABA) from overlapping resonances such as creatine and macromolecules. These sequences, however, generally have fixed and relatively long echo times. Therefore, for the absolute quantification of the edited spectrum, the T2 relaxation time must be taken into account. To measure the T2 relaxation time, the signal intensity has to be obtained at multiple echo times. However, on a coupled spin system such as GABA this is challenging, since the signal intensity of the target resonances is modulated not only by T2 decay but also by the J-coupling, which strongly influences the shapes and amplitudes of the edited signals, depending on the echo time. Here, we propose to refocus the J-modulation of the edited signal at different echo times by using chemical shift selective refocusing. In this way the echo time can be arbitrarily extended while preserving the shape of the edited signal. The method was applied in combination with the MEGA-sLASER editing technique to measure the in vivo T2 relaxation time of GABA (87 ± 11 ms, n = 10) and creatine (109 ± 8 ms, n = 10) at 7 T. The T1 relaxation time of these metabolites in a single subject was also determined (GABA, 1334 ± 158 ms; Cr, 1753 ± 12 ms). The T2 decay curve of coupled spin systems can be sampled in an arbitrary fashion without the need for signal shape correction. Furthermore, the method can be applied with any spectral editing technique. The shortest echo time of the method is limited by the echo time of the spectral editing technique.


Assuntos
Imageamento por Ressonância Magnética , Ácido gama-Aminobutírico/metabolismo , Creatina/metabolismo , Humanos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Fatores de Tempo
8.
NMR Biomed ; 26(10): 1213-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23508792

RESUMO

γ-Aminobutyric acid (GABA) and lactate are metabolites which are present in the brain. These metabolites can be indicators of psychiatric disorders or tumor hypoxia, respectively. The measurement of these weakly coupled spin systems can be performed using MRS editing techniques; however, at high field strength, this can be challenging. This is due to the low available B1 (+) field at high fields, which results in narrow-bandwidth refocusing pulses and, consequently, in large chemical shift displacement artifacts. In addition, as a result of the increased chemical shift displacement artifacts and chemical shift dispersion, the efficiency of the MRS method is reduced, even when using adiabatic refocusing pulses. To overcome this limitation, frequency offset corrected inversion (FOCI) pulses have been suggested as a mean to substantially increase the bandwidth of adiabatic pulses. In this study, a Mescher-Garwood semi-localization by adiabatic selection and refocusing (MEGA-sLASER) editing sequence with refocusing FOCI pulses is presented for the measurement of GABA and lactate in the human brain. Metabolite detection efficiencies were improved by 20% and 75% for GABA and lactate, respectively, when compared with editing techniques that employ adiabatic radiofrequency refocusing pulses. The highly efficient MEGA-sLASER sequence with refocusing FOCI pulses is an ideal and robust MRS editing technique for the measurement of weakly coupled metabolites at high field strengths.


Assuntos
Ácido Láctico/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Ácido gama-Aminobutírico/metabolismo , Encéfalo/metabolismo , Humanos , Imageamento Tridimensional , Ondas de Rádio
9.
Sovrem Tekhnologii Med ; 14(5): 15-23, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37181834

RESUMO

The aim of the study was to develop a methodology for conducting post-registration clinical monitoring of software as a medical device based on artificial intelligence technologies (SaMD-AI). Materials and Methods: The methodology of post-registration clinical monitoring is based on the requirements of regulatory legal acts issued by the Board of the Eurasian Economic Commission. To comply with these requirements, the monitoring involves submission of the review of adverse events reports, the review of developers' routine reports on the safety and efficiency of SaMD-AI, and the assessment of the system for collecting and analyzing developers' post-registration data on the safety and efficiency of medical devices. The methodology was developed with regard to the recommendations of the International Medical Device Regulators Forum and the documents issued by the Food and Drug Administration (USA). Field-testing of this methodology was carried out using SaMD-AI designed for diagnostic imaging. Results: The post-registration monitoring of SaMD-AI consists of three key stages: collecting user feedback, technical monitoring and clinical validation. Technical monitoring involves routine evaluation of SaMD-AI output data quality to detect and remove flaws in a timely manner, and to secure the product stability. Major outcomes include an ordered list of technical flaws in SaMD-AI and their classification using evidence from diagnostic imaging studies. The application of this methodology resulted in a gradual reduction in the number of studies with flaws due to timely improvements in artificial intelligence algorithms: the number of flaws decreased to 5% in various aspects during subsequent testing. Clinical validation confirmed that SaMD-AI is capable of producing clinically meaningful outputs related to its intended use within the functionality determined by the developer. The testing procedure and the baseline testing framework were established during the field testing. Conclusion: The developed methodology will ensure the safety and efficiency of SaMD-AI taking into account its specifics as intangible medical devices. The methodology presented in this paper can be used by SaMD-AI developers to plan and carry out the post-registration clinical monitoring.


Assuntos
Inteligência Artificial , Software , Estados Unidos , Algoritmos , Vigilância de Produtos Comercializados
10.
Phys Med Biol ; 65(1): 01NT02, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31775130

RESUMO

Respiratory-correlated 4D-MRI can characterize respiratory-induced motion of tumors and organs-at-risk for radiotherapy treatment planning and is a necessity for image guidance of moving tumors treated on an MRI-linac. Essential for 4D-MRI generation is a robust respiratory surrogate signal. We investigated the feasibility of the noise navigator as respiratory surrogate signal for 4D-MRI generation. The noise navigator is based on the respiratory-induced modulation of the thermal noise variance measured by the receive coils during MR acquisition and thus is inherently present and synchronized with MRI data acquisition. Additionally, the noise navigator can be combined with any rectilinear readout strategy (e.g. radial and cartesian) and is independent of MR image contrast and imaging orientation. For radiotherapy applications, the noise navigator provides a robust respiratory signal for patients scanned with an elevated coil setup. This is particularly attractive for widely used cartesian sequences where currently a non-interfering self-navigation means is lacking for MRI-based simulation and MRI-guided radiotherapy. The feasibility of 4D-MRI generation with the noise navigator as respiratory surrogate signal was demonstrated for both cartesian and radial readout strategies in radiotherapy setup on four healthy volunteers and two radiotherapy patients on a dedicated 1.5 T MRI scanner and two radiotherapy patients on a 1.5 T MRI-linac system. Moreover, the respiratory-correlated 4D-MR images showed liver motion comparable to a reference 2D cine MRI series for the volunteers. For 2D cartesian cine MRI acquisitions, both the noise navigator and respiratory bellows were benchmarked against an image navigator. Respiratory phase detection based on the noise navigator agreed 1.4 times better with the image navigator than the respiratory bellows did. For a 3D Stack-of-Stars acquisitions, the noise navigator was compared to radial self-navigation and a 1.7 times higher respiratory phase detection agreement was observed than for the respiratory bellows compared to radial self-navigation.


Assuntos
Fígado/efeitos da radiação , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/patologia , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Razão Sinal-Ruído , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/radioterapia , Movimento , Neoplasias Pancreáticas/radioterapia , Aceleradores de Partículas
11.
Phys Med Biol ; 65(12): 12NT01, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32330921

RESUMO

Motion is problematic during radiotherapy as it could lead to potential underdosage of the tumor, and/or overdosage in organs-at-risk. A solution is adaptive radiotherapy guided by magnetic resonance imaging (MRI). MRI allows for imaging of target volumes and organs-at-risk before and during treatment delivery with superb soft tissue contrast in any desired orientation, enabling motion management by means of (real-time) adaptive radiotherapy. The noise navigator, which is independent of the MR signal, could serve as a secondary motion detection method in synergy with MR imaging. The feasibility of respiratory motion detection by means of the noise navigator was demonstrated previously. Furthermore, from electromagnetic simulations we know that the noise navigator is sensitive to tissue displacement and thus could in principle be used for the detection of various types of motion. In this study we demonstrate the detection of various types of motion for three anatomical use cases of MRI-guided radiotherapy, i.e. torso (bulk movement and variable breathing), head-and-neck (swallowing) and cardiac. Furthermore, it is shown that the noise navigator can detect bulk movement, variable breathing and swallowing on a hybrid 1.5 T MRI-linac system. Cardiac activity detection through the noise navigator seems feasible in an MRI-guided radiotherapy setting, but needs further optimization. The noise navigator is a versatile and fast (millisecond temporal resolution) motion detection method independent of MR signal that could serve as an independent verification method to detect the occurrence of motion in synergy with real-time MRI-guided radiotherapy.


Assuntos
Imageamento por Ressonância Magnética , Movimentos dos Órgãos , Radioterapia Guiada por Imagem/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas , Radioterapia Guiada por Imagem/efeitos adversos , Razão Sinal-Ruído
12.
Phys Med Biol ; 64(7): 07NT02, 2019 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-30794995

RESUMO

We have developed a method to determine intrafraction motion of the prostate through automatic fiducial marker (FM) tracking on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients undergoing prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold FMs, had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR examination consisted of 55 sequentially obtained 3D datasets ('dynamics'), acquired over a 11 s period, covering a total of 10 min. FM locations in the first dynamic were manually identified by a clinician, FM centers in subsequent dynamics were automatically determined. Center of mass (COM) translations and rotations were determined by calculating the rigid transformations between the FM template of the first and subsequent dynamics. The algorithm was applied to 7315 dynamics over 133 scans of 29 patients and the obtained results were validated by comparing the COM locations recorded by the clinician at the halfway-dynamic (after 5 min) and end dynamic (after 10 min). The mean COM translations at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.9 mm and Z: 0.9 [Formula: see text] 2.0 mm. The mean rotation results at 10 min were X: 0.1 [Formula: see text] 3.9°, Y: 0.0 [Formula: see text] 1.3° and Z: 0.1 [Formula: see text] 1.2°. The tracking success rate was 97.7% with a mean 3D COM error of 1.1 mm. We have developed a robust, fast and accurate FM tracking algorithm for cine-MR data, which allows for continuous monitoring of prostate motion during MR-guided radiotherapy (MRgRT). These results will be used to validate automatic prostate tracking based on soft-tissue contrast.


Assuntos
Marcadores Fiduciais , Imagem Cinética por Ressonância Magnética/métodos , Movimento , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Algoritmos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
13.
Phys Med Biol ; 64(23): 235008, 2019 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-31698351

RESUMO

To develop a method to automatically determine intrafraction motion of the prostate based on soft tissue contrast on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients who underwent prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold fiducial markers (FMs), had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR session consisted of 55 sequentially obtained 3D data sets ('dynamics') and was acquired over an 11 s period, covering a total of 10 min. The prostate was delineated on the first dynamic of every dataset and this delineation was used as the starting position for the soft tissue tracking (SST). Each subsequent dynamic was rigidly aligned to the first dynamic, based on the contrast of the prostate. The obtained translation and rotation describes the intrafraction motion of the prostate. The algorithm was applied to 6270 dynamics over 114 scans of 29 patients and the results were validated by comparing to previously obtained fiducial marker tracking data of the same dataset. Our proposed tracking method was also retro-perspectively applied to cine-MR images acquired during MR-guided radiotherapy of our first prostate patient treated on the MR-Linac. The difference in the 3D translation results between the soft tissue and marker tracking was below 1 mm for 98.2% of the time. The mean translation at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.8 mm and Z: [Formula: see text] mm. The mean rotation results at 10 min were X: [Formula: see text], Y: 0.1 [Formula: see text] 0.6° and Z: 0.0 [Formula: see text] 0.7°. A fast, robust and accurate SST algorithm was developed which obviates the need for FMs during MR-guided prostate radiotherapy. To our knowledge, this is the first data using full 3D cine-MR images for real-time soft tissue prostate tracking, which is validated against previously obtained marker tracking data.


Assuntos
Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Algoritmos , Marcadores Fiduciais , Humanos , Imageamento Tridimensional/normas , Imagem Cinética por Ressonância Magnética/normas , Masculino , Movimento , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/normas , Rotação