Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Echocardiography ; 40(6): 562-567, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37212377

RESUMO

BACKGROUND: For severe mitral valve (MV) degenerative disease, repair is recommended. Prediction of repair complexity and referral to high volume centers can increase rates of successful repair. This study sought to demonstrate that TEE is a feasible imaging modality to predict the complexity of surgical MV repair. METHODS: Two hundred TEE examinations of patients who underwent MV repair (2009-2011) were retrospectively reviewed and scored by two cardiac anesthesiologists. TEE scores were compared to surgical complexity scores, which were previously assigned based on published methods. Kappa values were reported for the agreement of TEE and surgical scores. McNemar's tests were used to test the homogeneity of the marginal probabilities of different scoring categories. RESULTS: TEE scores were slightly lower (2[1,3]) than surgical scores (3[1,4]). The agreement was 66% between the scoring methods, with a moderate kappa (.46). Using surgical scores as the gold standard, 70%, 71%, and 46% of simple, intermediate and complex surgical scores, respectively, were correctly scored by TEE. P1, P2, P3, and A2 prolapse were easiest to identify with TEE and had the highest agreement with surgical scoring (P1 agreement 79% with kappa .55, P2 96% [kappa .8], P3 77% [kappa .51], A2 88% [kappa .6]). The lowest agreement between the two scores occurred with A1 prolapse (kappa .05) and posteromedial commissure prolapse (kappa .14). In the presence of significant disagreement, TEE scores were more likely to be of higher complexity than surgical. McNemar's test was significant for prolapse of P1 (p = .005), A1 (p = .025), A2 (p = .041), and the posteromedial commissure (p < .0001). CONCLUSION: TEE-based scoring is feasible for prediction of the complexity of MV surgical repair, thus allowing for preoperative stratification.


Assuntos
Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Ecocardiografia Transesofagiana/métodos , Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Estudos Retrospectivos , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/cirurgia , Prolapso
2.
Circulation ; 139(2): 155-168, 2019 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-30586698

RESUMO

BACKGROUND: The MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) has demonstrated that the HeartMate 3 (HM3) pump is associated with reduced strokes compared with the HeartMate II (HMII) device. We now perform a comprehensive analysis of stroke events to evaluate their longitudinal occurrence, clinical correlates, patterns, and impact on outcome across the 2-year duration of support. METHODS: MOMENTUM 3 is a randomized controlled trial of the HM3 centrifugal-flow pump versus the HMII axial-flow pump in patients with advanced heart failure, regardless of the intended goal of support (bridge to transplantation or destination therapy). Baseline and postimplantation clinical correlates of stroke events were assessed with multivariable analyses. Longitudinal patterns, including device association, type of stroke (hemorrhagic versus ischemic), changing severity of impairment assessed with the modified Rankin Scale (disabling [modified Rankin Scale score >3] versus nondisabling [modified Rankin Scale score ≤3]) over time, and association with outcome, were determined. RESULTS: In 361 patients with the intended implant (189 HM3 and 172 HMII), 65 strokes (40 ischemic strokes and 25 hemorrhagic strokes) occurred in 52 patients at a median of 131 (range, 1-733) days. No difference in stroke rate was noted between 0 and 180 days of follow-up between devices. However, stroke incidence in the long-term period (181-730 days after left ventricular assist device) was 3.3 times lower for the HM3 group (HM3: 0.04 versus HMII: 0.13 events per patient-year; odds ratio, 0.23; 95% CI, 0.08-0.63; P=0.01). Treatment with the HM3 pump was the only independent predictor of lower stroke events. We found no direct association of blood pressure or antithrombotic regimens with observed stroke rates. A stroke event significantly lowered 2-year postimplantation survival regardless of subtype or initial severity of neurological impairment compared with patients without a stroke (43±12% for hemorrhagic stroke, 57±9% for ischemic stroke, 51±11% for disabling, and 51±11% for nondisabling compared with 85±2% 2-year survival for patients without stroke). CONCLUSIONS: The HM3 pump is associated with a marked reduction in stroke rates compared with the HMII device, with benefits observed in the long-term period (>6 months). The occurrence of stroke of any type (hemorrhagic and ischemic) or of any functional severity (disabling and nondisabling) is predictive of a poor 2-year clinical outcome. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/ . Unique identifier: NCT02224755.


Assuntos
Isquemia Encefálica/prevenção & controle , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemorragias Intracranianas/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Idoso , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/mortalidade , Isquemia Encefálica/fisiopatologia , Avaliação da Deficiência , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hemorragias Intracranianas/diagnóstico , Hemorragias Intracranianas/mortalidade , Hemorragias Intracranianas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Esquerda
4.
Crit Care Med ; 43(1): e19-22, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25514727

RESUMO

OBJECTIVES: The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. PATIENT: This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. CONCLUSION: This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.


Assuntos
Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Artificial/efeitos adversos , Hemodinâmica/fisiologia , Taquicardia Ventricular/terapia , Adulto , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Masculino , Implantação de Prótese/métodos
5.
JACC Heart Fail ; 12(5): 893-901, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38276935

RESUMO

BACKGROUND: Myocardial recovery occurs in patients with advanced heart failure on left ventricular assist device (LVAD) support, but there is the premise that it is rare with uncertain results. OBJECTIVES: The goal of this study was to investigate the incidence and consequence of LVAD explant after myocardial recovery. METHODS: Using the United Network for Organ Sharing registry, LVAD implants in the United States between 2005 and 2020 were tracked until death, transplantation, or explant for myocardial recovery. The cohort undergoing explant was followed up for heart failure relapse (defined as relisting followed by delisting due to death, being too ill, or transplantation; or second durable LVAD implant). RESULTS: Of 15,728 LVAD implants, 126 patients underwent explant for recovery, which only occurred in 55 (38%) of 145 implanting centers. The crude cumulative incidence was 0.7% at 2 years, whereas the incidence reached 4.7% among designated centers in the selected young nonischemic cohort. Of 126 explanted patients, 76 (60%) were subsequently delisted for sustained recovery. Heart failure relapsing had a relatively higher hazard in the early phase, with a 30-day incidence of 6% (7 of 126) but tapered following with the freedom rate of 72.5% at 4 years. CONCLUSIONS: In the United States, LVAD explant for myocardial recovery was underutilized, leading to a very low incidence at the national level despite a realistic rate being achieved in designated centers for selected patients. With follow-up extending up to 4 years after explant, more than one-half were successfully removed and stayed off the waitlist, and approximately 70% were free from heart failure relapse events.


Assuntos
Remoção de Dispositivo , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Incidência , Estados Unidos/epidemiologia , Remoção de Dispositivo/estatística & dados numéricos , Adulto , Recuperação de Função Fisiológica , Sistema de Registros , Recidiva , Idoso , Estudos Retrospectivos
6.
J Thorac Cardiovasc Surg ; 167(1): 205-214.e5, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-35618532

RESUMO

OBJECTIVES: Although the SynCardia total artificial heart (SynCardia Systems, LLC) was approved for use as a bridge to transplantation in 2004 in the United States, most centers do not adopt the total artificial heart as a standard bridging strategy for patients with biventricular failure. This study was designed to characterize the current use and outcomes of patients placed on total artificial heart support. METHODS: The United Network of Organ Sharing Standard Transplant Research File was queried to identify total artificial heart implantation in the United States between 2005 and 2018. Multivariable Cox regression models were used for risk prediction. RESULTS: A total of 471 patients (mean age, 49 years; standard deviation, 13 years; 88% were male) underwent total artificial heart implantation. Of 161 transplant centers, 11 centers had cumulative volume of 10 or more implants. The 6-month cumulative incidence of mortality on the total artificial heart was 24.6%. The 6-month cumulative incidence of transplant was 49.0%. The 1-year mortality post-transplantation was 20.0%. Cumulative center volume less than 10 implants was predictive of both mortality on the total artificial heart (hazard ratio, 2.2, 95% confidence interval, 1.5-3.1, P < .001) and post-transplant mortality after a total artificial heart bridge (hazard ratio, 1.5, 95% confidence interval, 1.0-2.2, P = .039). CONCLUSIONS: Total artificial heart use is low, but the total artificial heart can be an option for biventricular bridge to transplant with acceptable bridge to transplant and post-transplant survival, especially in higher-volume centers. The observation of inferior outcomes in lower-volume centers raises questions as to whether targeted training, center certifications, and minimum volume requirements could improve outcomes for patients requiring the total artificial heart.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Artificial , Humanos , Masculino , Estados Unidos , Pessoa de Meia-Idade , Feminino , Transplante de Coração/efeitos adversos , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia , Incidência , Estudos Retrospectivos
7.
JTCVS Open ; 19: 94-113, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015439

RESUMO

Objective: The effect of mitral valve (MV) surgery on the natural history of ventricular arrhythmia (VA) in patients with arrhythmic MV prolapse remains unknown. We sought to evaluate the cumulative incidence of VA at 1 year after surgical mitral repair. Methods: A retrospective review of progressively captured data identified 204 consecutive patients who underwent elective MV repair for significant degenerative mitral regurgitation as a first-time cardiovascular intervention in a quaternary reference center between January 2018 and December 2020. A subset of 62 consecutive patients with diagnosed arrhythmic MV prolapse was further evaluated for recurrent VA after MV repair. Results: The median age was 62 years (range, 27-77 years) and 26 of 62 (41.9%) were female. The median time from initial mitral regurgitation/MV prolaspe diagnosis-to-referral was 13.8 years (interquartile range [IQR], 5.4-25) and from VA diagnosis-to-referral was 8 years (IQR, 3-10.6). Using the Lown-Wolf classification, complex VA (Lown grade ≥3) was identified in 36 of 62 patients (58%) at baseline, whereas 8 of 62 (13%) had a cardioverter/defibrillator implanted for primary (4/8) or secondary (4/8) prevention. Left ventricular myocardial scar was confirmed in 23 of 34 (68%) of patients scanned at baseline. The prevailing valve phenotype was bileaflet Barlow (59/62; 95.2%). All patients underwent surgical MV repair by the same team. Surgical repair was stabilized with an annuloplasty prosthesis (median size 36 mm [IQR, 34-38]). Concomitant procedures included tricuspid valve repair (51/62; 82.3%), cryo-maze ± left atrial appendage exclusion (14/62, 23%), and endocardial cryoablation of VA ectopy (4/62; 6.5%). The 30-day and 1-year freedom from recurrent VA were 98.4% and 75.9%, respectively. Absent VA after mitral repair was uniformly observed in patients with minor VA at baseline. Absent VA after mitral repair was uniformly observed in patients with minor VA preoperatively. Complex baseline VA was the strongest predictor of recurrent VA (hazard ratio, 10.8; 95% confidence interval, 1.4-84.2; P = .024), irrespective of myocardial fibrosis. Conclusions: In a series of 62 consecutive patients operated electively for arrhythmic mitral prolapse, VA remained undetected in 75.9% of patients at 1 year. Freedom from recurrent VA was greater among patients without complex VA preoperatively, whereas baseline Lown grade ≥3 was the strongest independent risk factor for recurrent VA at 1 year. These findings attest to the importance of early recognition and prompt referral of patients with mitral prolapse and progressive VA to specialty interdisciplinary care.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38367698

RESUMO

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

9.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38276933

RESUMO

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Sobrevivência de Enxerto , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Estudos Prospectivos , Estudos Retrospectivos , Doadores de Tecidos
10.
Catheter Cardiovasc Interv ; 81(6): 1072-4, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22718366

RESUMO

A 51-year-old male with untreated hepatitis C infection, cirrhosis, and dilated cardiomyopathy with a HeartMate II LVAD presented with right heart failure and cardiogenic shock, INR of 7, hemolysis, and renal failure. Acute LVAD thrombosis was suspected. Alteplase was injected into the inflow cannula of the LVAD with little effect. Intravenous alteplase was given but failed to restore an adequate pump output, resulting in the need for emergency pump exchange. The patient had an uncomplicated postoperative recovery and was discharged uneventfully. Inspection of the pump identified a thrombus wedged between the spines of the impeller. Our case highlights the challenges in managing pump thrombosis which is often resistant to thrombolysis and may instead rely upon prompt surgical intervention to be resolved.


Assuntos
Remoção de Dispositivo , Cardiopatias/terapia , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Falha de Prótese , Terapia Trombolítica , Trombose/terapia , Função Ventricular Esquerda , Evolução Fatal , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Trombose/diagnóstico , Trombose/etiologia , Falha de Tratamento , Resultado do Tratamento
11.
Circ J ; 77(1): 28-34, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23123553

RESUMO

Degenerative mitral valve disease is the most common etiology of mitral regurgitation in developed countries. Degenerative mitral valve disease should be distinguished from other valvular disease because most of the lesions caused by degenerative changes are amenable to valve repair as opposed to replacement, and successful durable repair with optimal timing can maintain the patient's normal life expectancy. Despite dramatic surgical progress in degenerative mitral valve repair over the past few decades and detailing of surgical indications in established practice guidelines, prevailing data suggest a significant number of patients are still not referred for surgery in a timely fashion or are even denied for surgery for inappropriate reasons. This article reviews the current surgical triggers which all practicing cardiovascular specialists should be familiar with and which should prompt immediate surgical referral.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Encaminhamento e Consulta , Cardiologia , Humanos , Fatores de Tempo
12.
J Card Surg ; 28(4): 467-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23646902

RESUMO

Quadricuspid aortic valve (QAV) is a rare congenital anomaly of the aortic valve. We describe transplanting a donor heart with a QAV with successful mid-term outcome.


Assuntos
Valva Aórtica/anormalidades , Cardiopatias/cirurgia , Transplante de Coração/métodos , Doadores de Tecidos , Idoso , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
J Card Surg ; 28(1): 19-22, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23231749

RESUMO

Unroofed coronary sinus (UCS) is a rare cardiac anomaly that results in communication between the coronary sinus and the left atrium. We described an unusual presentation of UCS in a 48-year-old female that was not corrected during an initial secundum ASD repair 22 years ago.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Seio Coronário/anormalidades , Seio Coronário/cirurgia , Comunicação Interatrial/cirurgia , Diagnóstico por Imagem , Feminino , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/etiologia , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia , Esternotomia , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia
14.
Eur Heart J Case Rep ; 7(10): ytad496, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37881358

RESUMO

Background: Heparin-induced thrombocytopaenia (HIT) is an immune-mediated reaction to heparin therapy that may lead to life-threatening thrombotic events. This disorder complicates intraoperative heparin use during left ventricular assist device (LVAD) implantation. Case summary: A 52-year-old man presented in acute decompensated heart failure. His admission laboratory studies were consistent with cardiogenic shock with a lactate of 6.1 mmol/L (ref range 0.50-1.99 mmol/L). Echocardiogram and CT scan demonstrated severe biventricular dysfunction and a left ventricular ejection fraction of 10%, as well as left upper lobe segmental pulmonary embolism. He was started on inotropes, diuretics, and a heparin infusion. Following heparin initiation, his platelets had decreased by 63% to a nadir of 39 000/µL (ref range 150 000-450 000/µL) and testing confirmed a diagnosis of HIT. His shock state worsened to INTERMACS 1 necessitating escalation of mechanical support. In preparation for HeartMate 3 LVAD implantation, he received 3 cycles of plasmapheresis with one session of IVIG perioperatively, resulting in a 60% reduction in the titre of heparin-dependent platelet antibodies. He underwent successful LVAD implantation including usage of intraoperative heparin, and was discharged home on post-operative Day 17, where he has remained stable on LVAD support. Discussion: Limited data exist on the perioperative management of patients with HIT undergoing LVAD implantation. Heparin is preferred to other antithrombin agents during surgery due to the availability of an immediate reversal agent. Plasmapheresis with IVIG is a potential management option to decrease heparin-dependent platelet antibodies in patients with HIT to allow for successful LVAD implantation.

15.
ASAIO J ; 69(1): e38-e41, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36583778

RESUMO

Total artificial heart is associated with increased incidence of thromboembolism, which can prove to be fatal. The presence of four metallic tilting discs increases the chances of thrombus formation and sudden obstruction of the valve in a closed position resulting in severe hemodynamic collapse. Such a condition is conventionally treated by a surgical approach for device change; however, this procedure is extremely high risk and associated with complications and poor outcomes. We describe two total artificial heart patients with sudden obstruction to the filling of the right side due to fixing of the atrioventricular valve in a closed position due to a thrombus. After a quick diagnosis by rescue transesophageal echocardiography, we successfully treated these patients with catheter-directed thrombolysis with minimal adverse outcomes. We propose a carefully weighed application of this approach in hemodynamically unstable patients too tenuous for a timely surgery and with low risk for bleeding.


Assuntos
Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Coração Artificial , Trombose , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Trombose/tratamento farmacológico , Trombose/etiologia , Trombose/diagnóstico , Catéteres/efeitos adversos , Coração Artificial/efeitos adversos , Terapia Trombolítica
16.
J Thorac Cardiovasc Surg ; 165(3): 1138-1148.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34627602

RESUMO

BACKGROUND: This study aims to describe the outcomes after heart transplantation using a bridge-to-bridge strategy with a sequence of extracorporeal membrane oxygenation (ECMO) support followed by temporary total artificial heart implantation (TAH-t). METHODS: A retrospective, multicenter analysis of 54 patients who underwent TAH-t implantation following an ECMO for cardiogenic shock was performed (ECMO-TAH-t group). A control group of 163 patients who underwent TAH-t implantation as a direct bridge to transplantation (TAH-t group) was used to assess this strategy's impact on outcomes. RESULTS: Fifty-four patients, averaging 47 ± 13 year old, underwent implantation of a TAH-t after 5.3 ± 3.4 days of ECMO perfusion for cardiogenic shock. In the ECMO-TAH-t group, 20 patients (20/54%; 37%) died after TAH-t implantation and 57 patients (57/163%; 35%) died in the TAH-t group (Gray test; P = .49). The top 3 causes of death of patients on TAH-t support were multisystem organ failure (40%), sepsis (20%), and neurologic events (20%). Overall, 32 patients (32/54%; 59%) underwent heart transplantation in the ECMO-TAH-t group compared with 106 patients (106/163%, 65%) in the TAH-t group (P = .44). No significant difference in survival was observed at 6 months, 1 year, and 3 years after heart transplant (ECMO-TAH-t group: 94%, 87%, and 80% vs 87%, 83%, and 76% in the TAH-t group, respectively). Deterioration of liver function (bilirubin, aspartate transaminase, and alanine aminotransferase levels on TAH-t) was associated with increased mortality before heart transplant in both groups. CONCLUSIONS: Sequential bridging from ECMO to TAH-t followed by heart transplantation is a viable option for a group of highly selected patients.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Coração Artificial , Coração Auxiliar , Humanos , Adulto , Pessoa de Meia-Idade , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Coração Artificial/efeitos adversos , Resultado do Tratamento
17.
Nat Rev Cardiol ; 20(4): 263-277, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36357709

RESUMO

Originally intended for life-saving salvage therapy, the use of temporary mechanical circulatory support (MCS) devices has become increasingly widespread in a variety of clinical settings in the contemporary era. Their use as a short-term, prophylactic support vehicle has expanded to include procedures in the catheterization laboratory, electrophysiology suite, operating room and intensive care unit. Accordingly, MCS device design and technology continue to develop at a rapid pace. In this Review, we describe the functionality, indications, management and complications associated with temporary MCS, together with scenario-specific utilization, goal-directed development and bioengineering of future devices. We address various considerations for the use of temporary MCS devices in both prophylactic and rescue scenarios, with input from stakeholders from various cardiovascular specialties, including interventional and heart failure cardiology, electrophysiology, cardiothoracic anaesthesiology, critical care and cardiac surgery.


Assuntos
Cardiologia , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/cirurgia , Coração , Choque Cardiogênico/terapia
18.
J Am Coll Cardiol ; 81(8): 729-740, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36813371

RESUMO

BACKGROUND: Simultaneous heart-kidney transplantation has been increasingly performed in end-stage heart failure patients with concurrent kidney dysfunction despite limited evidence supporting its indications and utility. OBJECTIVES: The purpose of this study was to investigate the effects and utility of simultaneously implanted kidney allografts with various degrees of kidney dysfunction during heart transplantation. METHODS: Using the United Network for Organ Sharing registry, long-term mortality was compared in recipients with kidney dysfunction who underwent heart-kidney transplantation (n = 1,124) vs isolated heart transplantation (n = 12,415) in the United States between 2005 and 2018. In heart-kidney recipients, contralateral kidney recipients were compared for allograft loss. Multivariable Cox regression was used for risk adjustment. RESULTS: Long-term mortality was lower among heart-kidney recipients than among heart-alone recipients when recipients were on dialysis (26.7% vs 38.6% at 5 years; HR: 0.72; 95% CI: 0.58-0.89) or had a glomerular filtration rate (GFR) of <30 mL/min/1.73 m2 (19.3% vs 32.4%; HR: 0.62; 95% CI: 0.46-0.82) and GFR of 30 to 45 mL/min/1.73 m2 (16.2% vs 24.3%; HR: 0.68; 95% CI: 0.48-0.97) but not in GFR of 45 to 60 mL/min/1.73 m2. Interaction analysis showed that the mortality benefit of heart-kidney transplantation continued up to GFR 40 mL/min/1.73 m2. The incidence of kidney allograft loss was higher among heart-kidney recipients than among contralateral kidney recipients (14.7% vs 4.5% at 1 year; HR: 1.7; 95% CI: 1.4-2.1). CONCLUSIONS: Heart-kidney transplantation relative to heart transplantation alone provided superior survival for dialysis-dependent recipients and non-dialysis-dependent recipients up to a GFR of approximately 40 mL/min/1.73 m2 but at the cost of almost twice the risk of kidney allograft loss than contralateral kidney allograft recipients.


Assuntos
Transplante de Coração , Transplante de Rim , Insuficiência Renal , Humanos , Estados Unidos , Rim , Taxa de Filtração Glomerular , Estudos Retrospectivos , Sobrevivência de Enxerto
19.
JTCVS Tech ; 17: 23-46, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36820352

RESUMO

Objective: The objective of this study was to compare short- and midterm clinical and echocardiographic outcomes according to the use of pledgeted sutures during aortic valve replacement. Methods: Patients with aortic stenosis or regurgitation requiring aortic valve replacement were enrolled in a prospective cohort study to evaluate the safety of a new stented bioprosthesis. Outcomes were analyzed according to the use of pledgets (pledgeted group) or no pledgets (nonpledgeted group). The primary outcome was a composite of thromboembolism, endocarditis, and major paravalvular leak at 5 years of follow-up. Secondary outcomes included multiple clinical endpoints and hemodynamic outcomes. Propensity score matching was performed to adjust for prognostic factors, and subanalyses with small valve sizes (<23 mm) and suturing techniques were performed. Results: The pledgeted group comprised 640 patients (59%), and the nonpledgeted group 442 (41%), with baseline discrepancies in demographic characteristics, comorbidities, and stenosis severity. There were no differences between groups in any outcome. After propensity score matching, the primary outcome occurred in 41 (11.7%) patients in the pledgeted and 36 (9.8%) in the nonpledgeted group (P = .51). The effective orifice area was smaller in the pledgeted group (P = .045), whereas no difference was observed for the mean or peak pressure gradient. Separate subanalyses with small valve sizes and suturing techniques did not show relevant differences. Conclusions: In this large propensity score-matched cohort, comprehensive clinical outcomes were comparable between patients who underwent aortic valve replacement with pledgeted and nonpledgeted sutures up to 5 years of follow-up, but pledgets might lead to a slightly smaller effective orifice area in the long run.

20.
Curr Opin Cardiol ; 27(2): 118-24, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22318215

RESUMO

PURPOSE OF REVIEW: To review selected recent publications on minimally invasive mitral valve surgery to help answer the question as to whether the minimally invasive approach should be routinely used in complex mitral valve repairs. RECENT FINDINGS: Other than cosmesis, there have not been demonstrable reproducible benefits of the minimally invasive approach. Although some workers report excellent results, there are other data that raise concern that complex repairs are less likely to be undertaken via the minimal access approach, resulting in lower repair rates, and also that the incidence of residual regurgitation may be higher. Some complications, such as stroke, may occur with greater frequency in patients having the minimally invasive approach. SUMMARY: The minimally invasive approach for complex mitral valve repair requires continued development and investigation, and current application should probably be largely restricted to high-volume reference minimally invasive surgery centers.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Doenças das Valvas Cardíacas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/cirurgia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa