1.
Pract Radiat Oncol ; 13(4): 314-320, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37140504

RESUMO

PURPOSE: Shorter courses of breast radiotherapy are offered as an alternative to 4 weeks of whole-breast irradiation after lumpectomy, including brachytherapy. A prospective phase 2multi-institution clinical trial to study 3-fraction accelerated partial breast irradiation delivered by brachytherapy was conducted. METHODS AND MATERIALS: The trial treated selected breast cancers after breast-conserving surgery with brachytherapy applicators that delivered 22.5 Gy in 3 fractions of 7.5 Gy. The planning treatment volume was 1 to 2 cm beyond the surgical cavity. Eligible women were age ≥45 years with unicentric invasive or in situ tumors ≤3 cm excised with negative margins and with positive estrogen or progesterone receptors and no metastases to axillary nodes. Strict dosimetric parameters were required to be met and follow up information was collected from the participating sites. RESULTS: Two hundred patients were prospectively enrolled; however, a total of 185 patients who were enrolled were followed for a median of 3.63 years. Three-fraction brachytherapy was associated with low chronic toxicity. There was excellent or good cosmesis in 94% of patients. There were no grade 4 toxicities. Grade 3 fibrosis at the treatment site was present in 1.7% and 32% percent had grades 1 or 2 fibrosis at the treatment site. There was 1 rib fracture. Other late toxicities included 7.4% grade 1 hyperpigmentation, 2% grade 1 telangiectasias, 1.7% symptomatic seromas, 1.7% abscessed cavities, and 1.1% symptomatic fat necrosis. There were 2 (1.1%) ipsilateral local recurrences, 2 (1.1%) nodal recurrences and no distant recurrences. Other incidents included one contralateral breast cancer and 2 second malignancies (lung). CONCLUSIONS: Ultra-short breast brachytherapy is feasible and has excellent toxicity and could be an alternative to standard 5-day, 10 fraction accelerated partial breast irradiation in eligible patients. Patients from this prospective trial will continue to be followed to evaluate long-term outcomes.


Assuntos
Braquiterapia , Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Neoplasias da Mama/patologia , Seguimentos , Hospitais , Mastectomia Segmentar , Estudos Prospectivos , Recidiva , Resultado do Tratamento
2.
Int J Radiat Oncol Biol Phys ; 104(1): 67-74, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30611839

RESUMO

PURPOSE: Shorter courses of accelerated partial-breast irradiation delivered as single-fraction intraoperative therapy are now offered as an alternative to 4 to 6 weeks of whole-breast irradiation after lumpectomy. However, this approach has potential shortcomings in patient selection and target volume definition and in dosimetric, radiobiological, and logistical issues. We designed a prospective, phase 2, multi-institution clinical trial to study 2- or 3-day accelerated partial breast irradiation delivered with brachytherapy applicators. METHODS AND MATERIALS: This trial treats select breast cancers after breast-conserving surgery with brachytherapy applicators that deliver 22.5 Gy in 3 fractions of 7.5 Gy. The planning treatment volume was 1 to 1.5 cm beyond the surgical cavity. Eligible women were aged ≥45 years with unicentric invasive or in situ tumors ≤3.0 cm with positive estrogen or progesterone receptors and no metastasis to axillary nodes that have been excised with negative margins. Strict dosimetric parameters were required to be met before acceptance into the trial. RESULTS: A group of 200 patients was prospectively enrolled and followed for a minimum of 6 months. Two- or 3-day brachytherapy was associated with low acute or subacute toxicity, 97.25% excellent or good cosmetic outcomes, and excellent local control in select breast cancers. CONCLUSIONS: Ultrashort breast brachytherapy is dosimetrically feasible and can be delivered with excellent short-term tolerance and low toxicity.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Margens de Excisão , Mastectomia Segmentar , Pessoa de Meia-Idade , Estudos Prospectivos , Lesões por Radiação/epidemiologia , Eficiência Biológica Relativa , Fatores de Tempo
4.
Am J Surg ; 192(4): 427-33, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16978943

RESUMO

BACKGROUND: This report presents the preliminary results and evaluation of the MammoSite balloon catheter (MammoSite Radiation Therapy System; Cytyc Corporation, Marlboro, MA) as the sole method of delivering partial breast irradiation to the lumpectomy bed with breast-conserving surgery in patients with pure ductal carcinoma in situ (DCIS). METHODS: Twelve institutions are participating in this phase II clinical study. A total of 133 patients have been enrolled and 100 patients have successfully completed the prescribed radiation therapy. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using iridium-192 high-dose rate brachytherapy. Patients who met the following criteria were selected for enrollment into the study: age 45 years or older, unicentric pure DCIS, mammographic lesion of 3 cm or less, negative margins as defined by 1 mm or more, postoperative final gross pathologic size of tumor of 5 cm or less, clinically node negative, and a postlumpectomy mammogram showing the absence of any residual suspicious microcalcifications. The placement of the MammoSite catheter was performed either at the time of the lumpectomy or postlumpectomy. The minimum distance from the balloon surface to the surface of the skin is greater than 5 mm. Data collection points are at time of enrollment, time of implant, 3 months, 6 months, and then yearly at 1- to 5-year follow-up visits. Data collected are local control rates, cosmetic outcome using the Harvard Scale, toxicities, serious adverse events, disease-free survival, cause-specific survival, and contralateral breast failure. The Van Nuys Prognostic Index scores were calculated for each patient. Local recurrence is defined as either invasive or noninvasive recurrence within the target volume. Ipsilateral elsewhere recurrence is defined as either an invasive or noninvasive recurrence occurring outside of the target volume in the previously treated breast. This recurrence is classified as a new primary tumor. RESULTS: The mean follow-up period was 9.5 months (range, 1-24 mo). The MammoSite catheter was explanted for the following reasons: inadequate skin distance (5.1%; 6 of 117), poor cavity conformance (5.1%; 6 of 117), positive margins (2.6%; 3 of 117), final histology (.85%; 1 of 117), and physician decision (.85%; 1 of 117). Of the patients in whom the MammoSite was explanted because of skin spacing or cavity conformance, 50% were at sites of new users (institutions that have placed fewer than 10 Mammosite catheters). Cosmetic results were rated as excellent in 63%, good in 35%, and fair in 2% in the 86 patients with a follow-up visit. Two patients were diagnosed with an ipsilateral local recurrence, 1 outside of the target volume and 1 true recurrence/marginal miss. One patient was diagnosed at 8 months and the other was diagnosed at 11 months. Both of these ipsilateral failures were DCIS. The Van Nuys Prognostic Index of these 2 patients was 9 and 8, respectively. Data collected showed the mean age at placement was 60.8 y, mean tumor size was 10.6 mm, mean actual closest surgical margin was 6.8 mm (range, .1-40 mm), a re-excision rate of 35%, postlumpectomy placement was 71%, and the mean skin-to-balloon surface distance was 13 mm with 89% > or =7 mm. No serious adverse events were reported. The infection rate was 4.0%. CONCLUSIONS: Accelerated partial breast irradiation delivered with the MammoSite balloon was clinically successful in patients entered into a phase II clinical study with pure DCIS, with results comparable with other studies reported in the literature that have evaluated use of the MammoSite balloon brachytherapy for delivery of radiation therapy in early breast cancers. Inadequate skin distance and poor cavity conformance were the main factors limiting the use of the MammoSite device. Cosmetic results were good to excellent in 98%. There have been 2 ipsilateral breast recurrences.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Carcinoma Intraductal não Infiltrante/radioterapia , Cateterismo , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Terapia Combinada , Feminino , Seguimentos , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Resultado do Tratamento
5.
Int J Radiat Oncol Biol Phys ; 55(2): 289-93, 2003 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-12527040

RESUMO

PURPOSE: We present the results of the initial clinical testing of the MammoSite balloon breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy. METHODS AND MATERIALS: Seventy patients were enrolled in a multicenter prospective trial testing the applicator for safety and performance. Fifty-four patients were implanted, and 43 patients were ultimately eligible for and received brachytherapy as the sole radiation modality after lumpectomy. Patients were staged T1N0M0 with negative pathologic margins and age >45 years. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using 192Ir high-dose-rate brachytherapy. A minimum skin-to-balloon surface distance of 5 mm was required for treatment. Device performance, complications, and cosmesis were assessed. RESULTS: Computed tomography imaging post-balloon inflation showed 8, 14, and 21 patients with 5-6 mm, 7-9 mm, and >10 mm of skin spacing, respectively. Two patients were explanted because of inadequate skin spacing and 7 because of suboptimal conformance of the surgical cavity to the applicator balloon. One patient was explanted because of positive nodal status and another because of age. The most common side effects related to device placement included mild erythema, drainage, pain, and echymosis. No severe side effects related to implantation, brachytherapy, or explantation occurred. Side effects related to radiation therapy were generally mild with erythema, pain, and dry desquamation being the most common. At 1 month, 88% of patients were evaluated as having good-to-excellent cosmetic results. CONCLUSIONS: The MammoSite balloon breast brachytherapy applicator performed well clinically. All eligible patients completed treatment. Side effects were mild to moderate and self-limiting. Skin-balloon surface distance and balloon-cavity conformance were the main factors limiting the initial use of the device.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Cateterismo , Mastectomia Segmentar , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos
6.
Brachytherapy ; 13(1): 17-22, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24041956

RESUMO

PURPOSE: Radiation Therapy Oncology Group (RTOG) 95-17, a Phase II trial to evaluate multicatheter brachytherapy (mCathBrachy) as the sole method of radiation therapy for Stage I-II breast cancer (BrCa), was the first cooperative group trial in North America to evaluate accelerated partial breast irradiation (APBI) and include patient-reported outcomes (PROs). This report presents the year-5 toxicity and cosmesis data. METHODS AND MATERIALS: After lumpectomy and axillary dissection for invasive BrCa (tumor size <3cm with zero to three positive lymph nodes), 100 patients (pts), 98 evaluable, were treated (txed) with mCathBrachy from 1997 to 2000 with 34Gy administered twice daily in 10 high-dose-rate fractions or 45Gy in 3.5-6 days as a low-dose-rate implant to 1-2cm beyond the lumpectomy bed. The PROs and physician-reported outcomes of toxicity, cosmesis, and tx satisfaction at year-5 are reported here, defined as data submitted 54-78 months after tx. RESULTS: Grade (G) 1-2 skin toxicity developed in 78% of the pts and G3 in 13% (no G4). The tx effects included skin dimpling/indentation (37%), fibrosis (45%), telangiectasias (45%), skin catheter marks (54%), and symptomatic fat necrosis (15%). Breast asymmetry was reported in 73%. Rates of excellent-to-good cosmesis were similar between PROs (66%) and radiation oncologists (68%). The PROs of tx satisfaction at year-5 was 75%. CONCLUSIONS: RTOG 95-17 documents the year-5 skin toxicity and tx effects of mCathBrachy APBI, which are associated with PROs of good-to-excellent cosmesis and high tx satisfaction. This emphasizes the importance of PROs when assessing BrCa tx. National Surgical Adjuvant Breast and Bowel Project B39/RTOG 0413 will allow for definitive comparisons between APBI and whole breast radiation therapy.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Mama/efeitos da radiação , Mamoplastia/métodos , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Feminino , Seguimentos , Humanos , Estadiamento de Neoplasias , Satisfação do Paciente , Dosagem Radioterapêutica , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
7.
Int J Radiat Oncol Biol Phys ; 85(5): 1179-85, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23182700

RESUMO

PURPOSE: To determine whether the American Society for Radiation Oncology (ASTRO) Consensus Statement (CS) recommendations for accelerated partial breast irradiation (APBI) are associated with significantly different outcomes in a pooled analysis from William Beaumont Hospital (WBH) and the American Society of Breast Surgeons (ASBrS) MammoSite® Registry Trial. METHODS AND MATERIALS: APBI was used to treat 2127 cases of early-stage breast cancer (WBH, n=678; ASBrS, n=1449). Three forms of APBI were used at WBH (interstitial, n=221; balloon-based, n=255; or 3-dimensional conformal radiation therapy, n=206), whereas all Registry Trial patients received balloon-based brachytherapy. Patients were divided according to the ASTRO CS into suitable (n=661, 36.5%), cautionary (n=850, 46.9%), and unsuitable (n=302, 16.7%) categories. Tumor characteristics and clinical outcomes were analyzed according to CS group. RESULTS: The median age was 65 years (range, 32-94 years), and the median tumor size was 10.0 mm (range, 0-45 mm). The median follow-up time was 60.6 months. The WBH cohort had more node-positive disease (6.9% vs 2.6%, P<.01) and cautionary patients (49.5% vs 41.8%, P=.06). The 5-year actuarial ipsilateral breast tumor recurrence (IBTR), regional nodal failure (RNF), and distant metastasis (DM) for the whole cohort were 2.8%, 0.6%, 1.6%. The rate of IBTR was not statistically higher between suitable (2.5%), cautionary (3.3%), or unsuitable (4.6%) patients (P=.20). The nonsignificant increase in IBTR for the cautionary and unsuitable categories was due to increased elsewhere failures and new primaries (P=.04), not tumor bed recurrence (P=.93). CONCLUSIONS: Excellent outcomes after breast-conserving surgery and APBI were seen in our pooled analysis. The current ASTRO CS guidelines did not adequately differentiate patients at an increased risk of IBTR or tumor bed failure in this large patient cohort.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Segunda Neoplasia Primária , Radioterapia (Especialidade) , Radioterapia Conformacional/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Consenso , Feminino , Humanos , Metástase Linfática , Mastectomia Segmentar , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Sistema de Registros , Sociedades Médicas , Carga Tumoral
8.
Am J Surg ; 194(4): 456-62, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17826055

RESUMO

OBJECTIVE: Patients with early-stage invasive ductal breast cancer were prospectively evaluated using MammoSite RTS balloon brachytherapy (RTS Cytyc Corp, Marlborough, MA) as the sole modality for delivering accelerated partial breast irradiation to the lumpectomy bed with breast-conserving surgery. This report presents the 5-year results of the treated patients. METHODS: From May 2000 to October 2001, 70 patients were enrolled in this prospective study. Forty-three patients completed accelerated partial breast irradiation with MammoSite brachytherapy following lumpectomy and axillary staging. Thirty-six patients have been followed for a median of 5.5 years (mean 65.2 months). Criteria for entry into the study were unifocal invasive ductal carcinoma, tumor size < or = 2 cm, age > or = 45 years, absence of extensive intraductal component, cavity size > or = 3 cm in 1 dimension, node-negative, and final margins negative per National Surgical Adjuvant Breast and Bowel Project definition. A minimum balloon-to-skin surface distance of 5 mm was required. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using iridium-192 high-dose-rate brachytherapy. Data on infection, seromas, cosmetic outcome, and toxicities were collected at 3 and 6 months and at yearly intervals. Local recurrences, both true recurrences in the lumpectomy bed and failures outside the initially treated target volume (elsewhere failures), were recorded. Contralateral breast failure rates were noted. RESULTS: The catheter was not implanted in 16 of the 70 enrolled patients due to cavity size not amenable to balloon placement (n = 10), ineligible by criteria (n = 4), and skin spacing (n = 2). Fifty-four patients were implanted and 43 were successfully treated with MammoSite balloon brachytherapy. Reasons for catheter explantation in 11 patients were poor cavity conformance in 7, inadequate skin spacing in 2, positive node in 1 and age less than 45 years in 1. Of the 43 patients who completed treatment, the infection rate was 9.3%. Seroma formation occurred in 32.6% of patients, of which 12% were symptomatic requiring aspiration. Asymptomatic fat necrosis was identified in 4 of the 43 patients, noted from time of catheter removal at 11, 14, 42, and 63 months. Good-excellent cosmetic outcomes were achieved in 83.3% of the 36 patients with more than 5 years of follow-up. Cosmetic outcomes were improved, with increased skin spacing having statistical significance at skin spacing > or = 7 mm. The only serious adverse events were 2 infections: mastitis and abscess. Seven of the 43 treated patients have been discontinued from follow-up. None had a local recurrence recorded at last visit. Reasons for exit from the study were death from metastatic disease (n = 3), lost to follow-up (n = 2), and placed in hospice for other medical conditions (n = 2). No local recurrences (either at the tumor bed or elsewhere in the breast) or regional recurrences have occurred in the 36 patients who have been followed for a median of 5.5 years. No contralateral cancers have developed. CONCLUSIONS: MammoSite balloon brachytherapy as a sole modality for delivering radiation to the tumor bed has been successful in achieving excellent local control in this initial clinical study of patients with early-stage invasive ductal breast cancer. This has been achieved with minimal toxicities and good-excellent cosmetic outcomes in 83.3%. Accelerated partial breast irradiation using the MammoSite balloon in a carefully selected group of patients has demonstrated 5-year local recurrence results comparable to those achieved with conventional whole breast radiation therapy and interstitial catheter brachytherapy as reported at 5-year data points in studies of these treatment modalities. Poor cavity conformance and inadequate skin distance were the main factors limiting use of the MammoSite device. Extended follow-up will be required to determine the long-term efficacy of this treatment modality.


Assuntos
Braquiterapia , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/radioterapia , Adulto , Braquiterapia/instrumentação , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS