Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38841916

RESUMO

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

2.
Rev Cardiovasc Med ; 23(5): 163, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-39077595

RESUMO

Background and Objective: As one of the most prevalent valvular pathologies affecting millions globally, moderate-to-severe tricuspid regurgitation (TR) predisposes to increased mortality. Despite the well-established risk of adverse outcomes, an overwhelming majority of TR patients are managed conservatively due to challenges associated with timely diagnosis, clinical course of the disease, competing comorbities that carry prohibitive surgical risk, and poor surgical outcomes. These challenges highlight the importance of transcatheter tricuspid valve replacement (TTVR) which has restructured TR management in promising and innovative ways. Methods: We start with an overview of the pathophysiology of TR considering its implications in management. We then elaborate on the current state of TR management, including its limitations, thereby highlighting the unique role of TTVR. This is followed by a review of perioperative considerations such as careful patient selection, role of multimodality imaging, the various imaging techniques that are available and their contribution towards successful TTVR. We then review the valves that are currently available and under investigation, including the latest data available on device efficacy and safety, and highlight the ongoing clinical trials. Results and Conclusions: TTVR is evolving at an exponential pace and has made its mark in the treatment of severe symptomatic tricuspid regurgitation. The promising results sustained by currently available devices and ongoing investigation of valves under development continue to pave the path for further innovation in transcatheter interventions. However, it is important to acknowledge and appreciate the novelty of this approach, the lack of long-term data on safety, efficacy, morbidity, and mortality, and use the lessons learned from real-world experiences to provide a definitive and reproducible solution for patients with symptomatic TR.

3.
J Clin Med ; 13(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38999548

RESUMO

Pulmonary embolism (PE) is a significant cause of cardiovascular mortality, with varying presentations and management challenges. Traditional treatment approaches often differ, particularly for submassive/intermediate-risk PEs, because of the lack of clear guidelines and comparative data on treatment efficacy. The introduction of pulmonary embolism response teams (PERTs) aims to standardize and improve outcomes in acute PE management through multidisciplinary collaboration. This review examines the conception, evolution, and operational mechanisms of PERTs while providing a critical analysis of their implementation and efficacy using retrospective trials and recent randomized trials. The study also explores the integration of advanced therapeutic devices and treatment protocols facilitated by PERTs. PERT programs have significantly influenced the management of both massive and submassive PEs, with notable improvements in clinical outcomes such as decreased mortality and reduced length of hospital stay. The utilization of advanced therapies, including catheter-directed thrombolysis and mechanical thrombectomy, has increased under PERT guidance. Evidence from various studies, including those from the National PERT Consortium, underscores the benefits of these multidisciplinary teams in managing complex PE cases, despite some studies showing no significant difference in mortality. PERT programs have demonstrated potentials to reduce morbidity and mortality, streamlining the use of healthcare resources and fostering a model of sustainable practice across medical centers. PERT program implementation appears to have improved PE treatment protocols and innovated advanced therapy options, which will be further refined as they are employed in clinical practice. The continued expansion of the capabilities of PERTs and the forthcoming results from ongoing randomized trials are expected to further define and optimize management protocols for acute PEs.

4.
Front Cardiovasc Med ; 10: 1180299, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38045907

RESUMO

New generation 3-dimensional matrix array intracardiac echocardiography catheters have become commercially available recently, increasing image plane options compared to 2-dimensional and older generation 3-dimensional intracardiac echocardiography catheters. They are beginning to play an important role in structural heart interventions, especially for transcatheter tricuspid interventions, due to advantages in some situations that increase image quality over transesophageal echocardiography.

5.
J Clin Med ; 12(1)2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36615141

RESUMO

Transcatheter aortic valve implantation (TAVI) has risen over the past 20 years as a safe and effective alternative to surgical aortic valve replacement for treatment of severe aortic stenosis, and is now a well-established and recommended treatment option in suitable patients irrespective of predicted risk of mortality after surgery. Studies of numerous devices, either newly developed or reiterations of previous prostheses, have been accruing. We hereby review TAVI devices, with a focus on commercially available options, and aim to present a guide for prosthesis tailoring according to patient-related anatomical and clinical factors that may favor particular designs.

6.
J Invasive Cardiol ; 35(1): E46-E54, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36495542

RESUMO

BACKGROUND: The effectiveness and safety of a contemporary combined approach that incorporates the novel intravascular lithotripsy (IVL) technology into conventional tools including atherectomy have yet to be studied. METHODS: We retrospectively included consecutive patients who underwent percutaneous coronary intervention (PCI) with IVL from March 2021 to February 2022. Effectiveness (residual stenosis of <30%) and safety outcomes (procedural complications and major adverse cardiovascular event [MACE] defined as a composite of all-cause death, myocardial infarction, or target vessel revascularization) were compared between patients undergoing IVL with and without atherectomy. RESULTS: A total of 109 patients underwent IVL, of whom 33 patients (30.3%) were treated with both IVL and atherectomy and had higher risk features including reduced cardiac function and more frequent use of mechanical circulatory support. Angiographic success for calcified de novo lesions was achieved in 85.7% and 90.6% of the combined and non-atherectomy groups, respectively (P=.49). Each group had one case of coronary perforation (P=.52) while major dissection occurred in 2 cases of calcific stent underexpansion in the combined group (6.1% vs 0%; P=.09). Thirty-day MACE occurred in 4.8% of patients including 3 deaths in the atherectomy group and 1 cardiac death and 1 myocardial infarction in the non-atherectomy group (P=.16). CONCLUSION: Procedural success and complications were similar in patients undergoing IVL with and without atherectomy when treating calcified de novo lesions. Those who required a combined approach represented a high-risk population with high mortality, suggesting that a multidisciplinary approach is needed to optimize case selection and care beyond PCI.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Estenose Coronária , Litotripsia , Infarto do Miocárdio , Intervenção Coronária Percutânea , Calcificação Vascular , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Calcificação Vascular/cirurgia , Estudos Prospectivos , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Infarto do Miocárdio/etiologia , Litotripsia/efeitos adversos , Aterectomia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária
7.
Expert Opin Drug Deliv ; 20(5): 689-701, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203200

RESUMO

INTRODUCTION: Onyx FrontierTM represents the latest iteration within the family of zotarolimus-eluting stents (ZES), designed for the treatment of coronary artery disease. Approval by the Food and Drug Administration was granted in May 2022, and Conformité Européenne marking followed in August 2022. AREAS COVERED: We hereby review the principal design features of Onyx Frontier, highlighting differences and similarities with other currently available drug-eluting stents. In addition, we focus on the refinements of this newest platform as compared with previous ZES versions, including the attributes yielding its exceptional crossing profile and deliverability. The clinical implications related to both its newest and inherited characteristics will be discussed. EXPERT OPINION: The nuances of the latest Onyx Frontier, together with the continuous refinement previously witnessed throughout the development of ZES, lead to a latest generation device ideal for a diverse spectrum of clinical and anatomical scenarios. In particular, its peculiarities will be of benefit in the settings often offered by a progressively aging population, such as high bleeding risk patients and complex coronary lesions.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Idoso , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Tecnologia , Intervenção Coronária Percutânea/efeitos adversos
8.
Int J Cardiol ; 364: 35-37, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35662560

RESUMO

INTRODUCTION: Despite the technological advances and increasing operator experience, the rate of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) has not decreased over time. With a continuous downward trend in post-TAVR length of stay, prolonged home-monitoring may have a key role in detecting potentially serious conduction abnormalities after TAVR discharge. METHODS: In this study, the ZioPatch-AT monitor was used to detect conduction abnormalities after TAVR discharge. The cardiac monitoring device was systematically provided to all patients having pre-existing right bundle branch block or developing intra-/peri-procedural conduction disturbances, in the absence of guideline indication for PPI at discharge. RESULTS: From a total of 75 patients at high-risk of conduction disturbances, 8 (11%) of them underwent PPI and most of them (6/8) were detected before symptoms' occurrence. Paired analysis between baseline and discharge electrocardiograms detected a significant widening of the QRS in all patients; on the contrary, PR length was significantly increased only in the group experiencing HAVB after discharge (p < 0.01). CONCLUSIONS: In an early post-TAVR discharge era, 30-day outpatient cardiac rhythm monitoring is potentially a safe solution to allow timely recognition of new conduction disturbances requiring PPI.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/etiologia , Doença do Sistema de Condução Cardíaco/terapia , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Humanos , Marca-Passo Artificial/efeitos adversos , Alta do Paciente , Fatores de Risco , Telemetria , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Prog Cardiovasc Dis ; 60(2): 259-266, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28743529

RESUMO

With increasing awareness to provide personalized care our institution applied the American College of Cardiology (ACC) Patient Navigator Program to identify hospitalized heart failure (HF) patients and improve transitions and outcomes. Utilizing a Navigator Team (NT) composed of a nurse and clinical pharmacist, we delivered evidenced-based interventions and hypothesized this approach would improve identification of HF inpatients and reduce the 30-day all-cause readmission rate. Patients were followed from admission to discharge and received at least one intervention, tailored to the patient's health literacy and social needs. The 30-day all-cause readmission rate was 17.6% for the Patient Navigator Program and 25.6% for the medical center. Compared to the medical center there was a statistically significant increase in education and follow-up. For patients who received specific NT interventions of education and follow-up the readmission rate was 10.3% and 6.1% respectively. Hospital programs can easily embed a NT into existing initiatives to further reduce the readmission rate.


Assuntos
Prestação Integrada de Cuidados de Saúde/organização & administração , Insuficiência Cardíaca/terapia , Recursos Humanos de Enfermagem Hospitalar/organização & administração , Equipe de Assistência ao Paciente/organização & administração , Alta do Paciente , Navegação de Pacientes , Readmissão do Paciente , Transferência de Pacientes , Farmacêuticos/organização & administração , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/enfermagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Papel do Profissional de Enfermagem , Educação de Pacientes como Assunto , Valor Preditivo dos Testes , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos , Fatores de Risco , Comportamento de Redução do Risco , Autocuidado , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa