Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 167: 109491, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33121893

RESUMO

Arsenic is a toxic metalloid which has been associated with a wide range of health effects in humans including skin abnormalities and an elevated risk of skin, bladder, kidney, and lung cancer, diabetes, and cardiovascular disease. The measurement of arsenic concentration in nail clippings is often used in population studies as an indicator of arsenic exposure. Portable X-ray fluorescence (XRF) is an emerging technique for measuring arsenic in nail clippings. In the current study, single toenail clippings from 60 Atlantic Canadian participants were assessed for arsenic using a new portable XRF approach. A mono-energetic portable XRF system using doubly curved crystal optics was used to measure each clipping for a total of 900 s. Energy spectra from each clipping were analyzed for arsenic characteristic X-rays to provide a normalized arsenic signal. The same clippings were then analyzed for arsenic concentration using a "gold standard" method of inductively coupled plasma mass spectrometry (ICP-MS). Nail clipping arsenic concentrations measured by ICP-MS ranged from 0.030 µg/g to 2.57 µg/g, with a median result of 0.14 µg/g. Portable XRF results for arsenic were compared against ICP-MS arsenic concentrations, with a linear equation of best fit determined between the two variables. A correlation coefficient of r = 0.77 was found from the 59 nail clippings returning an ICP-MS arsenic concentration above the limit of quantitation. When the comparison was limited to the 20 clippings having an XRF normalized signal at least twice as large as the associated uncertainty of measurement, the correlation coefficient was r = 0.89. With the selection of an arsenic concentration of 0.1 µg/g as a cut-off value between "exposed" and "non-exposed" individuals, the XRF method provided a test sensitivity of 76% and a specificity of 81%. The corresponding positive predictive value was 88% and the negative predictive value was 65%. The portable XRF technique used in this study shows promise as a means of assessing arsenic concentration in toenail clippings.


Assuntos
Arsênio/análise , Unhas/química , Espectrometria por Raios X/métodos , Calibragem , Humanos
2.
J Trace Elem Med Biol ; 62: 126603, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32623095

RESUMO

Zinc is an essential trace element in humans. Zinc deficiency can result in a range of serious medical conditions which include effects on growth and development, the immune system, the central nervous system, and the gastrointestinal system. Diagnosis of zinc deficiency is often precluded by the lack of a noninvasive and reliable biomarker. Zinc concentration in nail is considered an emerging biomarker of zinc status in humans. Whether zinc in nail accurately reflects zinc status is beyond the scope of the current study, but is an important research question. The development of a portable method to quickly assess zinc concentration from a single nail clipping could be a useful advance. In this study, single toenail clippings from 60 individuals living in Atlantic Canada were measured for zinc using a portable X-ray fluorescence (XRF) technique. These samples were obtained from the Atlantic PATH cohort, part of the largest chronic disease study ever performed in Canada. Each toenail clipping was measured using three 300 s trials with a mono-energetic portable XRF system. Results were then assessed using two different approaches to the XRF analysis: (1) factory-calibrated zinc concentrations were output from each trial, and (2) energy spectra were analyzed for the characteristic X-rays resulting from zinc. Following the measurement of zinc using the non-destructive portable XRF method, the same clippings were measured for zinc concentration using the "gold standard" technique of inductively coupled plasma-mass spectrometry (ICP-MS). A linear equation of best fit was determined for the relationship between average XRF output zinc concentration and ICP-MS zinc concentration, with a correlation coefficient r = 0.60. Similarly, a linear equation of best fit was found for the relationship between a normalized XRF energy spectrum zinc signal and ICP-MS zinc concentration, with a correlation coefficient r = 0.68. Individual ICP-MS zinc concentrations ranged from 32 µg/g to 140 µg/g, with a population average of 85 µg/g. The results of this study indicate that portable XRF is a sensitive method for the measurement of zinc in a single nail clipping, and provides a reasonable estimation of zinc concentration. Further method development is required before portable XRF be considered a routine alternative to ICP-MS for the assessment of zinc in nail clippings.


Assuntos
Fluorescência , Unhas/química , Zinco/química , Humanos , Espectrometria de Massas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa