1.
J Emerg Med ; 65(5): e403-e413, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37741738

RESUMO

BACKGROUND: Shoulder dislocations are among the most common orthopedic emergencies encountered in the emergency department (ED). Ultrasound-guided peripheral nerve blocks (USG-PNBs) are increasingly being used for acute pain management in the ED, but clinical evidence supporting their utility for shoulder dislocation is limited and often conflicting. OBJECTIVE: The aim of this review was to summarize and evaluate the utility of USG-PNB for analgesia during closed reduction of dislocated shoulders in the ED. METHODS: Adhering to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic literature search of the PubMed, Scopus, and Cochrane databases was performed from database inception to September 2022. We included clinical studies examining USG-PNB for pain management of dislocated shoulders in the ED. Information collected from eligible studies included patient demographic characteristics, USG-PNB approach, alternate analgesia techniques, anesthetic regimens, clinical outcomes, and adverse events. RESULTS: Five studies met inclusion criteria, all of which were randomized controlled trials comparing USG-PNB with procedural sedation and analgesia. Pooled patient satisfaction scores were similar for both analgesia methods (3.5 ± 0.6 vs. 3.9 ± 0.6 out of 5; p = 0.76). Patients managed with procedural sedation and analgesia achieved higher rates of overall shoulder reduction (100% vs. 67%; p < 0.001) and successful reduction on the first attempt (86% vs. 48%; p < 0.001). The USG-PNB groups in all but one study had shorter lengths of ED stay. Overall, USG-PNB was associated with a lower risk of adverse events and complications (3.9% vs. 24.9%; p < 0.001), especially adverse respiratory events (0% vs. 14.7%; p < 0.001). CONCLUSIONS: USG-PNBs performed by adequately trained emergency physicians should be considered a safe and effective alternative for analgesia during closed reduction of dislocated shoulders in the ED, particularly in patients with cardiorespiratory comorbidities.

2.
Am J Emerg Med ; 51: 285-289, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34785484

RESUMO

OBJECTIVES: Ultrasound (US) is an essential component of emergency department patient care. US machines have become smaller and more affordable. Handheld ultrasound (HUS) machines are even more portable and easy to use at the patient's bedside. However, miniaturization may come with consequences. The ability to accurately interpret ultrasound on a smaller screen is unknown. This pilot study aims to assess how screen size affects the ability of emergency medicine clinicians to accurately interpret US videos. METHODS: This pilot study enrolled a prospective convenience sample of emergency medicine physicians. Participants completed a survey and were randomized to interpret US videos starting with either a phone-sized screen or a laptop-sized screen, switching to the other device at the halfway point. 50 unique US videos depicting right upper quadrant (RUQ) views of the Focused Assessment with Sonography in Trauma (FAST) examination were chosen for inclusion in the study. There were 25 US videos per device. All of the images were previously obtained on a cart-based machine (Mindray M9) and preselected by the study authors. Participants answered "Yes" or "No" in response to whether they identified free fluid. The time that each participant took to interpret each video was also recorded. Following the assessment, participants completed a post-interpretation survey. The goal of the pilot was to determine the accuracy of image interpretation on a small screen as compared to a laptop-sized screen. Statistical analyses were performed using MATLAB (The MathWorks, Inc., Natick, MA). Nonparametric statistical tests were utilized to compare subgroups, with a Wilcoxon signed rank test used for paired data and a Wilcoxon rank sum test for unpaired data. RESULTS: 52 emergency medicine physicians were enrolled in the study. The median accuracy of US interpretation for phone versus laptop image screen was 88.0% and 87.6% (p = 0.67). The mean time to interpret with phone versus laptop screen was 293 and 290 s (p = 0.66). CONCLUSIONS: The study found no statistically significant difference in the accuracy of US interpretation nor time spent interpreting when the pre-selected RUQ videos generated on a cart-based ultrasound machine were reviewed on a phone-sized versus a laptop-sized screen. This pilot study suggests that the accuracy of US interpretation may not be dependent upon the size of the screen utilized.


Assuntos
Medicina de Emergência/instrumentação , Avaliação Sonográfica Focada no Trauma/instrumentação , Telemedicina/instrumentação , Gravação em Vídeo , Ferimentos e Lesões/diagnóstico por imagem , Telefone Celular , Competência Clínica , Computadores , Serviço Hospitalar de Emergência , Humanos , Simulação de Paciente , Projetos Piloto , Estudos Prospectivos
3.
J Ultrasound Med ; 37(11): 2667-2679, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29708268

RESUMO

OBJECTIVES: The purpose of this study was to conduct a systematic review of the evidence of educational outcomes associated with teaching ultrasonography (US) to medical students. METHODS: A review of databases through 2016 was conducted for research studies that reported data on teaching US to medical students. Each title and abstract were reviewed by teams of 2 independent abstractors to determine whether the article would be ordered for full-text review and subsequently by 2 independent authors for inclusion. Data were abstracted with a form developed a priori by the authors. RESULTS: Ninety-five relevant unique articles were included (of 6936 identified in the databases). Survey data showed that students enjoyed the US courses and desired more US training. Of the studies that assessed US-related knowledge and skill, most of the results were either positive (16 of 25 for knowledge and 24 of 58 for skill) or lacked a control (8 of 25 for knowledge and 27 of 58 for skill). The limited evidence (14 of 95 studies) of the effect of US training on non-US knowledge and skill (eg, anatomy knowledge or physical examination skill) was mixed. CONCLUSIONS: There is ample evidence that students can learn US knowledge and skills and that they enjoy and want US training in medical school. The evidence for the effect of US on external outcomes is limited, and there is insufficient evidence to recommend it for this purpose at this time.


Assuntos
Competência Clínica , Currículo , Educação de Graduação em Medicina/métodos , Ultrassom/educação , Humanos , Ultrassonografia
4.
Am J Emerg Med ; 34(6): 1125-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27090394

RESUMO

STUDY OBJECTIVES: Hypotension is a common side effect of propofol, but there are no reliable methods to determine which patients are at risk for significant propofol-induced hypotension (PIH). Ultrasound has been used to estimate volume status by visualization of inferior vena cava (IVC) collapse. This study explores whether IVC assessment by ultrasound can assist in predicting which patients may experience significant hypotension. METHODS: This was a prospective observational study conducted in the operating suite of an urban community hospital. A convenience sample of consenting adults planned to receive propofol for induction of anesthesia during scheduled surgical procedures were enrolled. Bedside ultrasound was used to measure maximum (IVCmax) and minimum (IVCmin) IVC diameters. IVC-CI was calculated as [(IVCmax-IVCmin)/IVCmax × 100%]. The primary outcome was significant hypotension defined as systolic blood pressure (BP) below 90mmHg and/or administration of a vasopressor to increase BP during surgery. RESULTS: The study sample comprised 40 patients who met inclusion criteria. Mean age was 55years, (95%CI, 49-60) with 53% female. 55% of patients had significant hypotension after propofol administration. 76% of patients with IVC-CI≥50% had significant hypotension compared to 39% with IVC-CI<50%, P=.02. IVC-CI≥50% had a specificity of 77.27% (95%CI, 64.29%-90.26%) and sensitivity of 66.67% (95%CI, 52.06%-81.28%) in predicting PIH. The odds ratio for PIH in patients with IVC-CI≥50% was 6.9 (95%CI, 1.7-27.5). CONCLUSION: Patients with IVC-CI≥50% were more likely to develop significant hypotension from propofol. IVC ultrasound may be a useful tool to predict which patients are at increased risk for PIH.


Assuntos
Anestésicos Intravenosos/efeitos adversos , Hipotensão/induzido quimicamente , Hipotensão/diagnóstico por imagem , Propofol/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Ultrassonografia
5.
Am J Emerg Med ; 32(10): 1179-82, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25171796

RESUMO

OBJECTIVE: The objective was to determine risk factors associated with difficult venous access (DVA) in the emergency department (ED). METHODS: This was a prospective, observational study conducted in the ED of an urban tertiary care hospital. Adult patients undergoing intravenous (IV) placement were consecutively enrolled during periods of block enrollment. The primary outcome was DVA, defined as 3 or more IV attempts or use of a method of rescue vascular access to establish IV access. Univariate and multivariate analyses for factors predicting DVA were performed using logistic regression. RESULTS: A total of 743 patients were enrolled, of which 88 (11.8%) met the criteria for DVA. In the adjusted analysis, only 3 medical conditions were significantly associated with DVA: diabetes (odds ratio [OR] 1.72, 95% confidence interval [CI] 1.1-2.8), sickle cell disease (OR 3.8, 95% CI 1.5-9.5), and history of IV drug abuse (OR 2.5, 95% CI 1.1-5.7). Notably, age, body mass index, and dialysis were not. Of patients who reported a history of requiring multiple IV attempts in the past for IV access, 14% met criteria for DVA on this visit (OR 7.7 95% CI 3-18). Of the patients who reported a history of IV insertion into the external jugular, ultrasound-guided IV placement, or a central venous catheter for IV access, 26% had DVA on this visit (OR 16.7, 95% CI 6.8-41). CONCLUSIONS: Nearly 1 of every 9 to 10 adults in an urban ED had DVA. Diabetes, IV drug abuse, and sickle cell disease were found to be significantly associated with DVA.


Assuntos
Anemia Falciforme/epidemiologia , Cateterismo Venoso Central/estatística & dados numéricos , Cateterismo Periférico/estatística & dados numéricos , Diabetes Mellitus/epidemiologia , Hospitais Urbanos , Abuso de Substâncias por Via Intravenosa/epidemiologia , Adolescente , Adulto , Fatores Etários , Idoso , Índice de Massa Corporal , Estudos de Coortes , Serviço Hospitalar de Emergência , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Philadelphia/epidemiologia , Estudos Prospectivos , Diálise Renal/estatística & dados numéricos , Fatores de Risco , Centros de Atenção Terciária , Adulto Jovem
7.
J Vasc Access ; 24(2): 271-276, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34250855

RESUMO

Clinicians commonly place ultrasound-guided intravenous catheters in peripheral veins for the diagnostic and therapeutic treatments of patients. This procedural skill requires practice and static phantom models are a commonly used education tool. Several commercial models that simulate blood vessels within tissue are available; however, they can be expensive. There are many examples of "Do-It-Yourself" models proposed; however, many of these require time to create the model. Mixing water and gelatin to make a gelatinous material, and the time necessary to set and store the phantom may deter people from pursuing these options. We propose Konnyaku jelly, or "yam cake," found in many Asian grocery stores, as the substrate to create a phantom model. When imaging with ultrasound, this model is similar to commercially available models, however the cost is less than $3.00 and preparation is about 5 min. We believe that Konnyaku jelly should be a more generally accepted homemade static model for phantom preparation.


Assuntos
Cateterismo , Gelatina , Humanos , Análise Custo-Benefício , Ultrassonografia/métodos , Imagens de Fantasmas , Ultrassonografia de Intervenção/métodos
8.
POCUS J ; 8(2): 159-164, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38099176

RESUMO

Objectives: This pilot study aims to determine if patients untrained in performing ultrasound can self-scan to obtain images under remote clinician teleguidance during a simulated telehealth encounter. This study also seeks to describe the patients' comfort level and barriers to performing an ultrasound examination on themselves using a handheld ultrasound device. Methods: This was a single center prospective observational cohort study conducted over a 4-month period in 2021. Patients were eligible if they had no prior training in the use of ultrasound and in the use of teleguidance. They voluntarily consented to participate at a single ambulatory internal medicine clinic. Results: 20 participants were enrolled and underwent teleguidance to ultrasound their own skin and soft tissues at the antecubital fossae. Six second video clips were evaluated by 2 subject matter experts using the Point of Care Ultrasound Image Quality scale. A score >7 was considered adequate for diagnostic interpretation. The average score was 10.15/14, with a minimum score of 5/14, and maximum score of 14/14 and a standard deviation (SD) of 2.39 using a two tailed Z-score. Setting alpha at 0.05 the 95% CI was (5.47-14.83). Conclusion: In a pilot study of 20 participants with no ultrasound experience, untrained healthy volunteers were able to perform technically acceptable and interpretable ultrasound scans using teleguidance by a trained clinician.

10.
Am J Emerg Med ; 30(9): 1950-4, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22795988

RESUMO

STUDY OBJECTIVES: Obtaining intravenous (IV) access in the emergency department (ED) can be especially challenging, and physicians often resort to placement of central venous catheters (CVCs). Use of ultrasound-guided peripheral IV catheters (USGPIVs) can prevent many "unnecessary" CVCs, but the true impact of USGPIVs has never been quantified. This study set out to determine the reduction in CVCs by USGPIV placement. METHODS: This was a prospective, observational study conducted in 2 urban EDs. Patients who were to undergo placement of a CVC due to inability to establish IV access by other methods were enrolled. Ultrasound-trained physicians then attempted USGPIV placement. Patients were followed up for up to 7 days to assess for CVC placement and related complications. RESULTS: One hundred patients were enrolled and underwent USGPIV placement. Ultrasound-guided peripheral IV catheters were initially successfully placed in all patients but failed in 12 patients (12.0%; 95 confidence interval [CI], 7.0%-19.8%) before ED disposition, resulting in 4 central lines, 7 repeated USGPIVs, and 1 patient requiring no further intervention. Through the inpatient follow-up period, another 11 patients underwent CVC placement, resulting in a total of 15 CVCs (15.0%; 95 CI, 9.3%-23.3%) placed. Of the 15 patients who did receive a CVC, 1 patient developed a catheter-related infection, resulting in a 6.7% (95 CI, 1.2%-29.8%) complication rate. CONCLUSION: Ultrasound prevented the need for CVC placement in 85% of patients with difficult IV access. This suggests that USGPIVs have the potential to reduce morbidity in this patient population.


Assuntos
Cateterismo Venoso Central/estatística & dados numéricos , Cateterismo Periférico/métodos , Ultrassonografia de Intervenção , Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Humanos , Masculino , Estudos Prospectivos , Falha de Tratamento , Ultrassonografia de Intervenção/métodos
11.
Am J Emerg Med ; 30(7): 1134-40, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22078967

RESUMO

INTRODUCTION: Ultrasound-guided peripheral intravenous catheters (USGPIVs) have been observed to have poor durability. The current study sets out to determine whether vessel characteristics (depth, diameter, and location) predict USGPIV longevity. METHODS: A secondary analysis was performed on a prospectively gathered database of patients who underwent USGPIV placement in an urban, tertiary care emergency department. All patients in the database had a 20-gauge, 48-mm-long catheter placed under ultrasound guidance. The time and reason for USGPIV removal were extracted by retrospective chart review. A Kaplan-Meier survival analysis was performed. RESULTS: After 48 hours from USGPIV placement, 32% (48/151) had failed prematurely, 24% (36/151) had been removed for routine reasons, and 44% (67/151) remained in working condition yielding a survival probability of 0.63 (95% confidence interval [CI], 0.53-0.70). Survival probability was perfect (1.00) when placed in shallow vessels (<0.4 cm), moderate (0.62; 95% CI, 0.51-0.71) for intermediate vessels (0.40-1.19 cm), and poor (0.29; 95% CI, 0.11-0.51) for deep vessels (≥1.2 cm); P < .0001. Intravenous survival probability was higher when placed in the antecubital fossa or forearm locations (0.83; 95% CI, 0.69-0.91) and lower in the brachial region (0.50; 95% CI, 0.38-0.61); P = .0002. The impact of vessel depth and location was significant after 3 hours and 18 hours, respectively. Vessel diameter did not affect USGPIV longevity. CONCLUSION: Cannulation of deep and proximal vessels is associated with poor USGPIV survival. Careful selection of target vessels may help improve success of USGPIV placement and durability.


Assuntos
Cateterismo Periférico , Ultrassonografia de Intervenção , Adolescente , Adulto , Fatores Etários , Idoso , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Cateterismo Periférico/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/estatística & dados numéricos , Veias/anatomia & histologia , Adulto Jovem
12.
Wilderness Environ Med ; 23(4): 343-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22835803

RESUMO

Retained foreign objects account for as much as 2% of soft tissue injuries sustained in the wilderness. Subcutaneously embedded fragments are often missed during the initial medical evaluation and may result in morbidity secondary to delayed removal. Although the utility of ultrasonography in the emergency department for the detection of retained objects is established, the potential use of point-of-care ultrasound to aid with foreign body removal in the field has not been well described. We present 2 case reports that demonstrate the value of ultrasonography in detecting and successfully removing foreign bodies sustained in the wilderness, and outline a procedural technique that minimizes morbidity and uses equipment available in wilderness medical field kits. We propose that with the advent of portable and handheld ultrasound units, foreign body removal in the field has become feasible and may decrease the morbidity of soft tissue injuries, particularly in austere and wilderness environments with limited access to immediate medical care.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Traumatismos da Mão/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Lesões dos Tecidos Moles/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Feminino , Corpos Estranhos/cirurgia , Traumatismos da Mão/cirurgia , Humanos , Traumatismos do Joelho/cirurgia , Masculino , Lesões dos Tecidos Moles/cirurgia , Madeira , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/cirurgia
13.
AEM Educ Train ; 5(2): e10584, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33817542

RESUMO

BACKGROUND: Over the past two decades, studies have demonstrated that lung ultrasound is useful in diagnosing alveolar interstitial syndrome, which is seen in patients with decompensated congestive heart failure (CHF). METHODS: We studied medical students performing lung ultrasound on patients admitted to the hospital with a presumed diagnosis of decompensated CHF in a prospective convenience observation study. Two ultrasound fellowship-trained emergency medicine attendings independently reviewed the lung ultrasounds at a later date, blinded to the students' interpretation and other clinical information, to confirm ultrasound findings and assess for inter-rater reliability of the lung ultrasound using intraclass correlation coefficients (ICCs). RESULTS: Thirty-six patients were enrolled in the study resulting in 653 unique lung zones scanned. The zones were imaged and classified as being normal (B-lines < 3) or pathologic (B-lines ≥ 3). The novice scanners' interpretation was compared to expert reviews using ICCs. The ICC was 0.88, with a 95% confidence interval of 0.87 to 0.90, for all lung zones scanned. CONCLUSION: There was almost perfect agreement between novice practitioners and experts when determining the presence of pathologic B-lines in individual patients.

14.
J Vasc Access ; 22(5): 692-696, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32962536

RESUMO

BACKGROUND: The optimal method for teaching ultrasound guided peripheral IV (USGPIV) insertion is unknown. Poor needle tip visualization has been cited for USGPIV failure. Twinkle artifact (TA), visualized with color Doppler, is used in other clinical settings. Our objective was to investigate whether teaching students USGPIV placement utilizing TA would enhance needle tip visualization and improve first pass success. METHODS: This was a prospective, randomized study of premedical and preclinical medical students without prior USGPIV experience. Students were given a standardized didactic session on USGPIV placement before being randomized and separated to learn and practice USGPIV with or without TA (control). The students were given 5 min to perform USGPIV on phantom models. The primary outcome was the rate of first pass success. Secondary outcomes included total time to cannulation, rate of posterior venous wall puncture, and total number of attempts. RESULTS: Rates of first pass success were similar in both the TA (82%) and control groups (57%), p = 0.095. There was a difference in the mean time to cannulation. The TA group achieved success at 50.76 s (SD 26.93) while the control group achieved success at 85.30 s (SD 65.47), p = 0.048. CONCLUSION: In this study of utilizing TA to aid in USGPIV placement, students were able to achieve successful cannulation in a shorter amount of time. There was no significant difference in first pass success. Future studies should utilize a larger sample size and evaluate the utility of TA when placing USGPIV on patients.


Assuntos
Artefatos , Cateterismo Periférico , Cateterismo Periférico/efeitos adversos , Humanos , Estudos Prospectivos , Punções , Ultrassonografia de Intervenção
15.
J Vasc Access ; 22(6): 891-897, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33023394

RESUMO

BACKGROUND: Ultrasound (U/S) guided peripheral IV catheter (PIV) placement is often needed after unsuccessful traditional IV attempts. Commercial U/S PIV training phantoms are expensive and difficult to alter. Non-commercial phantoms have been described; however, there has been no comparison of these models. The primary objectives of this study were to compare the echogenic and haptic properties of various non-commercial phantoms. Secondary objectives were to characterize the cost and ease of making the phantoms. METHODS: This prospective observational study trialed six unique phantom models: Amini Ballistics; Morrow Ballistics; University of California San Diego (UCSD) gelatin; Rippey Chicken; Nolting Spam; and Johnson Tofu. Total cost and creation time were noted. Emergency Ultrasound Fellowship trained physicians performed U/S guided PIV placement on each model to evaluate their resemblance to human tissue haptic and echogenicity properties, utility for training, and comparability to commercial phantoms (Likert scale 1-5; higher performance = 5). RESULTS: The Rippey model scored highest for each primary objective with an aggregate score of 4.8/5. UCSD ranked second and Nolting last for all primary objectives, with aggregate scores 3.7/5 and 1.3/5 respectively. Cost of production ranged from $4.39 (Johnson) to $29.76 (UCSD). Creation times ranged from 10 min (Johnson) to 120 min (UCSD). CONCLUSION: In our study the Rippey model performed best and offered a mid-level cost and creation time. Non-commercial U/S phantoms may represent cost-effective and useful PIV practice tools. Future studies should investigate the utility of these phantoms in teaching U/S guided PIV to novices and compare non-commercial to commercial phantoms.


Assuntos
Cateterismo Periférico , Ultrassonografia de Intervenção , Cateterismo Periférico/efeitos adversos , Catéteres , Humanos , Imagens de Fantasmas , Ultrassonografia
16.
J Am Coll Emerg Physicians Open ; 1(5): 1101-1103, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33145564

RESUMO

Pulmonary ultrasound is a useful tool in the diagnosis and resuscitation of emergency department (ED) patients with dyspnea. We present the case of a patient who was diagnosed with E-cigarette or vaping product use-associated lung injury (EVALI) using pulmonary ultrasound. Many of these cases are diagnosed using x-ray, computerized tomography, or bronchoscopy and to our knowledge this is the first published case that demonstrates utility of ultrasound in diagnosing EVALI. While more investigation is needed on the use of this technique, the patient in this case was diagnosed with EVALI based on positive history, presence of normal cardiac function, non-cardiogenic pulmonary edema on ultrasound, and absence of pulmonary infection.

18.
Cureus ; 11(1): e3960, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30956912

RESUMO

It can be difficult to distinguish between syncope and seizure. Some stigmata of seizure include post-ictal period, tongue-biting or incontinence. A less common finding after a seizure is a posterior shoulder dislocation. Posterior shoulder dislocation is commonly missed and may be the only finding after a seizure, thus aiding in diagnosis. In this case report, we discuss the incidence of posterior shoulder dislocations and their utility in differentiating syncope from seizure, as well as the ability to diagnose and evaluate for proper reduction of posterior shoulder dislocations using ultrasound.

19.
Cureus ; 11(10): e5900, 2019 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-31763102

RESUMO

Introduction Interprofessional collaboration (IPC) increases patient safety. IPC is learned through task-based exercises, such as ultrasound (U/S)-guided arterial lines. We set out to teach U/S-guided arterial lines as a framework to improve IPC between emergency medicine and neurosurgery residents. The objectives of the study were to provide a U/S session to teach the proper arterial line placement technique, to assess post-workshop arterial line placement competency and attitude toward U/S for procedural guidance, and to improve interdepartmental relationships through IPC. Methods The course was completed in 2018 and consisted of pre-workshop assignments, the workshop, a competency assessment, and a post-workshop survey for neurosurgical residents. After a didactic and hands-on training session, trainees completed a simulated U/S-guided arterial line placement. Trainees then completed a post-workshop assessment. Results There were a total of 21 participants out of 24 total residents, an 87.5% participation rate. Prior to the workshop, on a 5-point Likert scale, where 1 is not at all likely and 5 is very likely, the residents reported they would use U/S 1.7/5, with 57% of respondents answering 1 out of 5. After the workshop, on the same Likert scale, the residents reported using U/S first 3.6/5 (P < 0.05) with 52% of the respondents answering 4 out of 5. After the course, the belief that the landmark technique is non-inferior decreased to 28.6% of respondents. Conclusions The overall goal of this workshop was to improve patient care through continuing education. Using IPC as the framework, the workshop significantly increased the reported likelihood of using U/S for arterial line placement.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa