Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Res Cardiol ; 110(1): 40-49, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32335689

RESUMO

BACKGROUND: Currently, there are no recommendations regarding the minimum duration of in-hospital monitoring after transfemoral (TF) transcatheter aortic valve replacement (TAVR) and practices are extremely heterogeneous. We, therefore, aimed to evaluate length of stay (LOS) and predictive factors for late discharge after TF TAVR using data from the FRANCE TAVI registry. METHODS: TAVR was performed in 12,804 patients in 48 French centers between 2013 and 2015. LOS was evaluated in 5857 TF patients discharged home. LOS was calculated from TAVR procedure (day 0) to discharge. The study population was divided into three groups based on LOS values. Patients discharged within 3 days constituted the "very early" discharge group, patients with a LOS between 3 and 6 days constituted the "early" discharge group, and patients with a length of stay > 6 days constituted the "late" discharge group. RESULTS: The median LOS was 7 (5-9) days and was extremely variable among centers. The proportion of patients discharged very early, early, and late was 4.4% (n = 256), 33.7% (n = 1997), and 61.9% (n = 3624) respectively. Variables associated with late discharge were female sex, co-morbidities, major complications, self-expandable valve, general anesthesia, and a significant center effect. In contrast, history of previous pacemaker was a protective factor. The composite of death and re-admission in the very early and early versus late discharge groups was similar at 30 days (3.3% vs. 3.5%, p = 0.66). CONCLUSIONS: LOS is extremely variable after TF TAVR in France. Co-morbidities and complications were predictive factors of late discharge after TAVI. Interestingly, the use of self-expandable prosthesis and general anesthesia may also contribute to late discharge. Our results confirm that early discharge is safe.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Tempo de Internação/tendências , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Cateterismo Periférico/métodos , Feminino , Artéria Femoral , Seguimentos , Humanos , Masculino , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Ann Pathol ; 30(5): 344-9, 2010 Oct.
Artigo em Francês | MEDLINE | ID: mdl-21055521

RESUMO

AIM: To study the composition of foodstuffs (sausage, merguez, chipolata) on microscopic examination. MATERIAL AND METHODS: Six sausages, merguez, and chipolatas, sold in supermarkets were studied. The samples were weighed before and after dehydration to assess the water composition. Foodstuffs specimens were formalin-fixed, paraffin-embedded and analyzed on microscopic examination. Proportions of different tissues were assessed by morphometric analysis. RESULTS: Specimens contained a high proportion of water (40 to 55%). Striated muscular fibers represented from 0.7 to 15.3% for the sausages and the merguez, and from 61 to 76.5% for the chipolatas. Sausages and merguez contained from 43.3 to 49.2% of adipose tissue. All the specimens had fibrous tissue and most of them had small fragments of bone and cartilaginous tissue. Fragments of salivar glands were found in the sausages and fragments of lymphoid tissue were found in merguez. There were neither parasite nor brain tissue. Manufacturer wrote on the label the presence of "meat" with no information about the nature and the proportion of tissues in the foodstuffs specimens. Prices of the foodstuffs were globally correlated to the quantity of muscular fibers in the specimens. CONCLUSION: Pathological studies are not performed in France for the control of foodstuffs. Microscopic analysis could be interesting, as well as biochemical and bacteriological studies, in order to identify the nature and the proportion of tissues involved in the composition of the foodstuffs, to search tissues with potential risk of pathogenic agents transmission, and to search for some parasites.


Assuntos
Análise de Alimentos/métodos , França , Patologia
3.
J Integr Med ; 17(2): 107-114, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30792149

RESUMO

OBJECTIVE: The use of animal models of aortic stenosis (AS) remains essential to further elucidate its pathophysiology and to evaluate new therapeutic strategies. The waved-2 mouse AS model has been proposed; data have indicated that while aortic regurgitation (AR) is effectively induced, development of AS is rare. We aimed to evaluate the effect of high-fat diet (HFD) and vitamin D3 supplementation in this model. METHODS: HFD and subcutaneous vitamin D3 injections were initiated at the age of 6 weeks until the age of 6 (n = 16, 6-month treatment group) and 9 (n = 11, 9-month treatment group) months. Twelve waved-2 mice without supplementation were used as control. Echocardiography was performed at 3, 6 and 9 months. Blood serum analysis (calcium, 1,25(OH)2D3 and cholesterol), histology and immunohistochemistry (CD-31, CD-68 and osteopontin) were evaluated at the end of the experiment (6 or 9 months). RESULTS: Total cholesterol and 1,25(OH)2D3 were significantly increased relative to the control group. HFD and vitamin D3 supplementation did result in improvements to the model, since AS was only detected in 6 (15.3%) mice (2 in the 3 groups) and AR was developed in the remaining animals. Echocardiographic parameters, fibrosis, thickness, inflammation and valvular calcification, were not significantly different between the 6-month treatment and control groups. Similar results were also observed in the 9-month treatment group. CONCLUSION: These results suggest that HFD and vitamin D3 supplementation have no effect in the waved-2 mouse model. This model essentially mimics AR and rarely AS. Further studies are needed to find a reliable animal model of AS.


Assuntos
Estenose da Valva Aórtica/tratamento farmacológico , Colecalciferol/administração & dosagem , Receptores ErbB/genética , Animais , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/genética , Estenose da Valva Aórtica/metabolismo , Colecalciferol/sangue , Colesterol/sangue , Dieta Hiperlipídica/efeitos adversos , Suplementos Nutricionais/análise , Modelos Animais de Doenças , Receptores ErbB/metabolismo , Feminino , Humanos , Masculino , Camundongos
4.
Arch Cardiovasc Dis ; 112(4): 234-240, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30639198

RESUMO

BACKGROUND: France has a long history of successful cardiovascular research and scientific innovations, but its continued success cannot be taken for granted. AIMS: To identify current obstacles to cardiovascular research in France and to crystallize the analysis into recommendations for maintained and enhanced research excellence in the future. METHODS: The French Society of Cardiology set up seven Working Groups, each comprising four to eight cardiologists, covering a spectrum of research institutes, hospitals, specialties, ages and research experience. The Working Groups met regularly in person or by conference call to analyse experiences, refine situation assessments and formulate recommendations for improvements. Results and suggestions were presented to a Core Team, which worked to synthesize, prioritize and organize the findings into a consolidated situation assessment and generate a set of action-orientated recommendations. RESULTS: Four key areas of action were identified: stronger focus on the generation of high-quality data; facilitation of future cardiovascular research; greater promotion and support for research among young cardiologists; and increased focus and support for communications. Most recommendations targeted structural shortcomings and may be implemented at low additional financial cost. CONCLUSIONS: It is possible to maintain, and even increase, the quality of cardiovascular research in France and to boost the conversion of successful projects into high-impact publications, without major increases in funding. Intense collaboration between specialties and organizations is necessary to achieve sustainable results.


Assuntos
Pesquisa Biomédica/normas , Cardiologia/normas , Doenças Cardiovasculares , Publicações Periódicas como Assunto/normas , Controle de Qualidade , Projetos de Pesquisa/normas , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/terapia , Consenso , Comportamento Cooperativo , Difusão de Inovações , Previsões , França , Humanos , Comunicação Interdisciplinar
5.
Circ Cardiovasc Interv ; 12(4): e007597, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30998397

RESUMO

BACKGROUND: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. METHODS AND RESULTS: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. CONCLUSIONS: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
EuroIntervention ; 14(3): e264-e271, 2018 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-29599103

RESUMO

AIMS: Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. METHODS AND RESULTS: All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. CONCLUSIONS: Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Consenso , Humanos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
7.
Arch Cardiovasc Dis ; 109(8-9): 457-64, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27342810

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is recommended in patients with severe aortic stenosis that is either inoperable or at high-risk for surgical valve replacement. AIMS: To evaluate trends in the feasibility and safety of transfemoral TAVI over the past 4 years. METHODS: Between 2010 and 2013, all consecutive patients undergoing TAVI in our institution were included in a prospective registry. Population characteristics and 30-day and 1-year outcomes were analysed. Outcomes were classified according to the Valve Academic Research Consortium-2. RESULTS: Overall, 429 patients underwent TAVI; transfemoral access was used in 368 (85.7%). The proportion of patients treated via a transfemoral approach increased (70.1% to 89.9%; P<0.0001) and the use of prior balloon aortic valvuloplasty decreased (44.7% to 11.2%; P<0.0001). The mean logistic EuroSCORE decreased significantly from 19.4±10.9% to 15.8±8.7% (P=0.01). The 30-day mortality rate did not change significantly (6.4% vs. 5.6%; P=0.99). Similarly, rates of major vascular complications (12.8% vs. 15.4%; P=0.87) and stroke (2.1% vs. 1.4%; P=0.75) remained unchanged. Mean length of stay after TAVI decreased significantly from 8.9±11.3 days to 4.8±4.7 days (P=0.002) and 72 (50.3%) patients were discharged early in 2013. One-year survival increased significantly from 81.0% to 94.4% (P=0.03). CONCLUSIONS: Over the past 4 years, TAVI has been increasingly performed using a transfemoral approach. Treated patients are at lower-risk with less co-morbidity. Thirty-day mortality and complications remained unchanged, but length of stay after TAVI and 1-year mortality decreased dramatically.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco , Substituição da Valva Aórtica Transcateter/tendências , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Aortografia , Causas de Morte/tendências , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa