Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(5): 051803, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800477

RESUMO

The COHERENT Collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220 MeV/c^{2} using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9 keV_{nr}. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6 kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants α_{D}<0.64, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

2.
Phys Rev Lett ; 131(22): 221801, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101357

RESUMO

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ^{127}I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of 9.2_{-1.8}^{+2.1}×10^{-40} cm^{2}. This corresponds to a value that is ∼41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on ^{127}I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be 5.2_{-3.1}^{+3.4}×10^{-40} and 2.2_{-0.5}^{+0.4}×10^{-40} cm^{2}, respectively.

3.
Phys Rev Lett ; 129(8): 081801, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36053683

RESUMO

We measured the cross section of coherent elastic neutrino-nucleus scattering (CEvNS) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source at Oak Ridge National Laboratory. New data collected before detector decommissioning have more than doubled the dataset since the first observation of CEvNS, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT Collaboration determined the cross section to be (165_{-25}^{+30})×10^{-40} cm^{2}, consistent with the standard model, giving the most precise measurement of CEvNS yet. The timing structure of the neutrino beam has been exploited to compare the CEvNS cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino nonstandard interactions while testing lepton flavor universality and measures the weak mixing angle as sin^{2}θ_{W}=0.220_{-0.026}^{+0.028} at Q^{2}≈(50 MeV)^{2}.

4.
Phys Rev Lett ; 126(1): 012002, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480779

RESUMO

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10^{-39} cm^{2}-consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

5.
Phys Rev Lett ; 123(23): 231106, 2019 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-31868502

RESUMO

Dual-phase xenon detectors lead the search for keV-scale nuclear recoil signals expected from the scattering of weakly interacting massive particle (WIMP) dark matter, and can potentially be used to study the coherent nuclear scattering of MeV-scale neutrinos. New capabilities of such experiments can be enabled by extending their nuclear recoil searches down to the lowest measurable energy. The response of the liquid xenon target medium to nuclear recoils, however, is not well characterized below a few keV, leading to large uncertainties in projected sensitivities. In this work, we report a new measurement of ionization signals from nuclear recoils in liquid xenon down to the lowest energy reported to date. At 0.3 keV, we find that the average recoil produces approximately one ionization electron; this is the first measurement of nuclear recoil signals at the single-ionization-electron level, approaching the physical limit of liquid xenon ionization detectors. We discuss the implications of these measurements on the physics reach of xenon detectors for nuclear-recoil-based WIMP dark matter searches and the detection of coherent elastic neutrino-nucleus scattering.

6.
Science ; 357(6356): 1123-1126, 2017 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-28775215

RESUMO

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross section is by far the largest of all low-energy neutrino couplings. This mode of interaction offers new opportunities to study neutrino properties and leads to a miniaturization of detector size, with potential technological applications. We observed this process at a 6.7σ confidence level, using a low-background, 14.6-kilogram CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the standard model for this process, were observed in high signal-to-background conditions. Improved constraints on nonstandard neutrino interactions with quarks are derived from this initial data set.

7.
Afr J Med Med Sci ; 33(3): 219-24, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15819467

RESUMO

The prevalence of S. haematobium infection in 18 Local Government Area (LGA) in Ondo state was determined by examining pupils from randomly selected schools in the state. A total of 4266 urine samples were examined and 1303 (30.5%) were infected with the parasite. The infection was recorded in both rural and urban communities in each LGA. The overall prevalence was significantly higher in males (33.7%) than in females (26.0%) (P = -0.001). The LGA exhibiting the highest overall prevalence of infection was Akure north (86.2%; Cl, 0.82-0.9). The infection was most common in subjects between the ages of 11 and 15 years. Seven species of aquatic snails were encountered and B. (P). globosus was the most abundant and widespread species. The Owena river/dam in Idanre LGA was richest in molluscan fauna. B. (P). globosus and Biomphalaria pfeifferi shedding cercariae were recovered from Owena river and dam. The study shows that there were spatial heterogeneities in the prevalence of infections in both human population and the snail intermediate hosts. The implications of the clustering nature of the disease, for a successful control program in the state, were discussed.


Assuntos
Esquistossomose Urinária/epidemiologia , Adolescente , Distribuição por Idade , Animais , Criança , Feminino , Água Doce/parasitologia , Humanos , Masculino , Moluscos/parasitologia , Nigéria/epidemiologia , Prevalência , População Rural , Esquistossomose Urinária/transmissão , Instituições Acadêmicas , Distribuição por Sexo , Inquéritos e Questionários , Clima Tropical , População Urbana
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa