Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Surg ; 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39352812

RESUMO

OBJECTIVE: To determine the influence of operating room familiarity on surgeon stress. BACKGROUND: Regulating surgeon stress may improve patient safety. This study evaluated how assisting surgeon and operating room familiarity influence intraoperative heart rate variability among surgeons. METHODS: Attending surgeons from seven specialties within four university hospitals in France were enrolled from 11/01/20-12/31/21. Vagal tone, an indicator of stress derived from heart rate variability, was assessed during the first five minutes after incision using the root mean square of successive differences (RMSSD). Higher RMSSD values indicate greater vagal tone. Team familiarity was quantified as the cumulative time the attending and assisting surgeons had operated together in the past, while operating rooms in which the surgeon conducted >10% of their operations were termed familiar. The effect of each on the RMSSD was assessed via a linear mixed-effect model adjusting for the random effect of the surgeon and possible confounders. RESULTS: Overall, 643 surgeries performed by 37 surgeons were included. Median surgeon age was 49 years, 29(78.4%) were male, and 22(59.5%) were professors. Surgeons spent an average of 21.2 hours with the assisting surgeon prior to surgery and conducted 585(91.0%) of their operations in a familiar operating room. For every 10 additional hours spent operating together, ln(RMSSD) significantly increased by 0.018 (95%CI: 0.003 to 0.033, P=0.016). Familiar operating rooms also tended to increase surgeon ln(RMSSD) [0.098 (95%CI: -0.007 to 0.203, P=0.068)]. CONCLUSION: Familiar assisting surgeons, and potentially operating rooms, increased surgeon vagal tone. Maintaining a stable operating room environment may improve surgeon stress and patient care.

2.
Ann Surg ; 279(5): 891-899, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37753657

RESUMO

OBJECTIVE: To associate surgeon-anesthesiologist team familiarity (TF) with cardiac surgery outcomes. BACKGROUND: TF, a measure of repeated team member collaborations, has been associated with improved operative efficiency; however, examination of its relationship to clinical outcomes has been limited. METHODS: This retrospective cohort study included Medicare beneficiaries undergoing coronary artery bypass grafting (CABG), surgical aortic valve replacement (SAVR), or both (CABG+SAVR) between January 1, 2017, and September 30, 2018. TF was defined as the number of shared procedures between the cardiac surgeon and anesthesiologist within 6 months of each operation. Primary outcomes were 30- and 90-day mortality, composite morbidity, and 30-day mortality or composite morbidity, assessed before and after risk adjustment using multivariable logistic regression. RESULTS: The cohort included 113,020 patients (84,397 CABG; 15,939 SAVR; 12,684 CABG+SAVR). Surgeon-anesthesiologist dyads in the highest [31631 patients, TF median (interquartile range)=8 (6, 11)] and lowest [44,307 patients, TF=0 (0, 1)] TF terciles were termed familiar and unfamiliar, respectively. The rates of observed outcomes were lower among familiar versus unfamiliar teams: 30-day mortality (2.8% vs 3.1%, P =0.001), 90-day mortality (4.2% vs 4.5%, P =0.023), composite morbidity (57.4% vs 60.6%, P <0.001), and 30-day mortality or composite morbidity (57.9% vs 61.1%, P <0.001). Familiar teams had lower overall risk-adjusted odds of 30-day mortality or composite morbidity [adjusted odds ratio (aOR) 0.894 (0.868, 0.922), P <0.001], and for SAVR significantly lower 30-day mortality [aOR 0.724 (0.547, 0.959), P =0.024], 90-day mortality [aOR 0.779 (0.620, 0.978), P =0.031], and 30-day mortality or composite morbidity [aOR 0.856 (0.791, 0.927), P <0.001]. CONCLUSIONS: Given its relationship with improved 30-day cardiac surgical outcomes, increasing TF should be considered among strategies to advance patient outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Medicare , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento
3.
Ann Thorac Surg ; 117(4): 796-803, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37660965

RESUMO

BACKGROUND: Surgical treatment of asymptomatic severe aortic stenosis (AS) has been gaining attention ever since the results of the Early Surgery Versus Conventional Treatment in Very Severe Aortic Stenosis (RECOVERY) and Aortic Valve replacement versus conservative treatment in Asymptomatic seveRe aortic stenosis (AVATAR) trials showed survival benefits with early surgical aortic valve replacement (SAVR). This study analyzed the long-term clinical and echocardiographic outcomes of SAVR in asymptomatic severe AS. METHODS: Between 2002 and 2020, 272 patients with asymptomatic severe AS and a left ventricular ejection fraction ≥50% underwent SAVR with or without concomitant aortic surgery and met the study criteria. The median follow-up was 8.5 years (interquartile range, 6-12.8 years), for a total of 2584 patient-years. The time course of the left ventricular mass index (LVMI) and the average E/E' (ratio of the Doppler-derived E wave to the tissue Doppler-derived E' wave) were assessed using 594 postoperative echocardiograms. The association of preoperative LVMI and average E/E' with survival was assessed using Cox proportional hazards. RESULTS: There was no operative mortality. On longitudinal analyses, LVMI improved in patients who presented with moderate or severe preoperative left ventricular hypertrophy (LVH). However, after the early decline in average E/E', there was a late increase to greater than upper limit normal, particularly in patients with a preoperative average E/E'≥14. Postoperative survival was 100%, 94%, 84%, and 76% at 1, 5, 10, and 15 years, respectively, comparable to age- and sex-matched expected survival on the basis of the US general population. On adjusted Cox survival analysis, only moderate to severe LVH was associated with a survival penalty (hazard ratio], 2.32; 95% CI, 1.02-5.27; P = .045). CONCLUSIONS: In asymptomatic patients with AS, SAVR restores survival and improves LVH, but patients with diastolic dysfunction are left with persistent dysfunction. Presentation with moderate or severe LVH at the time of surgery translated to a survival penalty. This observational study supports early SAVR in this population before development of LVH, although further investigation is needed.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-37839658

RESUMO

OBJECTIVE: Transatrial transcatheter mitral valve replacement reduces complexity during mitral valve replacements involving high-risk patients with mitral annular calcification. This study examines trends in transatrial transcatheter mitral valve replacement use and outcomes. METHODS: Patients in the Society of Thoracic Surgeons database from 2014 to 2021 with mitral annular calcification undergoing transatrial transcatheter mitral valve replacement were included. Exclusion criteria were hypertrophic cardiomyopathy, congenital mitral valve disease, ventricular assist device placement, or prior mitral valve surgery. Primary outcomes were operative mortality and major adverse cardiac events compared between the Early (2014-2017, N = 71) and Recent (2018-2021, N = 151) eras. Parsimonious multivariable regression assessed select possible confounders for trends in major adverse cardiac events. RESULTS: Overall, 222 transatrial transcatheter mitral valve replacements at 104 hospitals were identified. Annual volume increased from 6 in 2014 to 43 in 2021. Median hospital volume was 1, maximum hospital volume was 17, and 10 or more replacements were performed at 4 hospitals. Mortality and major adverse cardiac events occurred in 10.4% and 22.5% of patients, respectively. Compared with the Early era patients, Recent era patients were more often elective (79.5% vs 64.8%) and were approached via sternotomy (90.1% vs 80.3%, all P < .05). Despite similar predicted risk of mortality (9.6% ± 11.1% vs 11.0% ± 6.0%; P = .61), Recent patients had reduced mortality (3.3% vs 25.4%, P < .001) and major adverse cardiac events (18.5% vs 31.0%; P = .057). On univariate and multivariable analyses, the Recent surgical era was significantly associated with lower mortality (0.10 [0.04-0.29]; P < .001) and lower major adverse cardiac events (0.48 [0.25-0.94]; P = .032), respectively. There were no preoperative characteristics that were significant confounders for the difference in major adverse cardiac events. CONCLUSIONS: Mortality and major adverse cardiac events after transatrial transcatheter mitral valve replacement have decreased significantly in the contemporary era independent of changes in major patient and operative characteristics. Transatrial transcatheter mitral valve replacement will have a future role in patients with mitral annular calcification.

6.
ACS Synth Biol ; 3(12): 966-8, 2014 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-25524100

RESUMO

Owl ( www.owlcad.org ) is a biodesign automation tool that generates electronic datasheets for synthetic biological parts using common formatting. Data can be retrieved automatically from existing repositories and modified in the Owl user interface (UI). Owl uses the data to generate an HTML page with standard typesetting that can be saved as a PDF file. Here we present the Owl software tool in its alpha version, its current UI, its description of input data for generating a datasheet, its example datasheets, and the vision of the tool's role in biodesign automation.


Assuntos
Bases de Dados Genéticas , Software , Biologia Sintética/métodos , Automação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa