Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Heart J ; 40(10): 820-830, 2019 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-30452631

RESUMO

AIMS: Catheter ablation is considered the treatment of choice for many tachyarrhythmias, but convincing 'real-world' data on efficacy and safety are lacking. Using Swedish national registry data, the ablation spectrum, procedural characteristics, as well as ablation efficacy and reported adverse events are reported. METHODS AND RESULTS: Consecutive patients (≥18 years of age) undergoing catheter ablation in Sweden between 01 January 2006 and 31 December 2015 were included in the study. Follow-up (repeat ablation and vital status) was collected through 31 December 2016. A total of 26 642 patients (57 ± 15 years, 62% men), undergoing a total of 34 428 ablation procedures were included in the study. In total, 4034 accessory pathway/Wolff-Parkinson-White syndrome (12%), 7358 AV-nodal re-entrant tachycardia (21%), 1813 atrial tachycardia (5.2%), 5481 typical atrial flutter (16%), 11 916 atrial fibrillation (AF, 35%), 2415 AV-nodal (7.0%), 581 premature ventricular contraction (PVC, 1.7%), and 964 ventricular tachycardia (VT) ablations (2.8%) were performed. Median follow-up time was 4.7 years (interquartile range 2.7-7.0). The spectrum of treated arrhythmias changed over time, with a gradual increase in AF, VT, and PVC ablation (P < 0.001). Decreasing procedural times and utilization of fluoroscopy with time, were seen for all arrhythmia types. The rates of repeat ablation differed between ablation types, with the highest repeat ablation seen in AF (41% within 3 years). The rate of reported adverse events was low (n = 595, 1.7%). Death in the immediate period following ablation was rare (n = 116, 0.34%). CONCLUSION: Catheter ablations have shifted towards more complex procedures over the past decade. Fluoroscopy time has markedly decreased and the efficacy of catheter ablation seems to improve for AF.


Assuntos
Arritmias Cardíacas , Ablação por Cateter , Adulto , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/estatística & dados numéricos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Suécia/epidemiologia , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 42(11): 1431-1439, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31495941

RESUMO

BACKGROUND: Primary indication for catheter ablation of atrial fibrillation (AF) is to reduce symptoms and improve health-related quality of life (HRQoL). There are data showing differences between the genders and between younger and older patients. To evaluate this, we studied a large Scandinavian cohort of patients referred for catheter ablation of AF. METHODS: Consecutive patients filled out the ASTA questionnaire, assessing symptoms, HRQoL, and perception of arrhythmia, prior to ablation. Patients were recruited from four Swedish and one Danish tertiary center. RESULTS: A total of 2493 patients (72% men) filled out the ASTA questionnaire. Women experienced eight of the nine ASTA scale symptoms more often than men. Patients <65 years reported four symptoms more often, only tiredness was more frequent in those ≥65 years (P = .007). Women and patients <65 years experienced more often palpitations and regarding close to fainting and this was more common among women, no age differences were seen. Women and men scored differently in 10 of the 13 HRQoL items. Only negative impact on sexual life was more common in men (P < .001). Older patients reported more negative influence in four of the HRQoL items and the younger in one; ability to concentrate. CONCLUSIONS: Women experienced a more pronounced symptom burden and were more negatively affected in all HRQoL concerns, except for the negative impact on sexual life, where men reported more influence of AF. Differences between age groups were less pronounced. Disease-specific patient-reported outcomes measures (PROMs) add important information where gender differences should be considered in the care.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Qualidade de Vida , Fatores Etários , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta , Autorrelato , Fatores Sexuais , Avaliação de Sintomas
4.
Artigo em Inglês | MEDLINE | ID: mdl-38842971

RESUMO

BACKGROUND: There is limited information on the mode of arrhythmia initiation in idiopathic ventricular fibrillation (IVF). A non-pause-dependent mechanism has been suggested to be the rule. OBJECTIVES: The aim of this study was to assess the mode and characteristics of initiation of polymorphic ventricular tachycardia (PVT) in patients with short or long-coupled PVT/IVF included in THESIS (THerapy Efficacy in Short or long-coupled idiopathic ventricular fibrillation: an International Survey), a multicenter study involving 287 IVF patients treated with drugs or radiofrequency ablation. METHODS: We reviewed the initiation of 410 episodes of ≥1 PVT triplet in 180 patients (58.3% females; age 39.6 ± 13.6 years) with IVF. The incidence of pause-dependency arrhythmia initiation (prolongation by >20 ms of the preceding cycle length) was assessed. RESULTS: Most arrhythmias (n = 295; 72%) occurred during baseline supraventricular rhythm without ambient premature ventricular complexes (PVCs), whereas 106 (25.9%) occurred during baseline rhythm including PVCs. Nine (2.2%) arrhythmias occurred during atrial/ventricular pacing and were excluded from further analysis. Mode of PVT initiation was pause-dependent in 45 (15.6%) and 64 (60.4%) of instances in the first and second settings, respectively, for a total of 109 of 401 (27.2%). More than one type of pause-dependent and/or non-pause-dependent initiation (mean: 2.6) occurred in 94.4% of patients with ≥4 events. Coupling intervals of initiating PVCs were <350 ms, 350-500 ms, and >500 ms in 76.6%, 20.72%, and 2.7% of arrhythmia initiations, respectively. CONCLUSIONS: Pause-dependent initiation occurred in more than a quarter of arrhythmic episodes in IVF patients. PVCs having long (between 350 and 500 ms) and very long (>500 ms) coupling intervals were observed at the initiation of nearly a quarter of PVT episodes.

5.
Pacing Clin Electrophysiol ; 36(1): e23-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21410725

RESUMO

Change of the retrograde atrial activation sequence during radiofrequency (RF) ablation of left-side accessory pathway can be due to another accessory pathway, another mechanism for the tachycardia, or due to intraatrial conduction block, partial or complete, caused by RF delivery to a site proximal to the site of insertion of the accessory pathway. In this case report, a temporary complete intraatrial conduction block was created by RF delivery proximal to the site of accessory pathway insertion, causing a change in the retrograde atrial activation sequence during ongoing tachycardia that was terminated by ablation at the insertion site of accessory pathway.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Fibrilação Atrial/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Taquicardia Supraventricular/complicações , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa