Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Am Heart J ; 273: 21-34, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38570020

RESUMO

BACKGROUND: Optimal first-trimester anticoagulation is still challenging in pregnant women with mechanical heart valves (MHVs) requiring high-dose warfarin. This multicenter prospective study aims to determine the optimal anticoagulation regimens for pregnant patients with MHVs. METHODS: All women were allocated to one of three treatment options during first trimester including lone low-molecular-weight heparin (LMWH), combination of LMWH + 2.5 mg warfarin, and LMWH+4 mg warfarin. Primary maternal outcome included a combination of death, thromboembolism, severe bleeding, and need for treatment of mechanical valve thrombosis (MVT). Any fetal loss was determined as primary fetal outcome. RESULTS: The study included 78 pregnancies in 65 women with MHVs. Primary maternal outcome rate was 44%, 12.5%, 3.5%, respectively. The rates of primary maternal outcome (44 vs 3.5%, P < .001), obstructive MVT (16 vs 0%, P = .04), MVT requiring treatment (28 vs 0%, P = .003), and cerebral embolism (24 vs 3.4%, P = .041) were found to be significantly higher in lone LMWH group compared to LMWH + 4 mg warfarin group. Moreover, the rates of primary maternal outcome (12.5 vs 44%, P = .015) and treatment for MHV thrombus (4.2 vs 28%, P = .049) were significantly lower in LMWH + 2.5 mg warfarin group compared to lone LMWH group. The incidences of fetal loss were 8 (32%) in the lone LMWH group, 8 (33.3%) in LMWH + 2.5 mg warfarin group, and 11 (37.9%) in LMWH + 4 mg warfarin group (P = .890 for 3-group).Warfarin related-embryopathy was not observed in any case. CONCLUSIONS: The combined anticoagulation strategy of LMWH plus low-dose warfarin during the first trimester of pregnancy may result in less maternal complications with comparable fetal outcomes in patients with MHVs. CONDENSED ABSTRACT: Low-molecular-weight heparin (LMWH) is thought to be safer for the fetus, however it is suspected to be less protective for the mother. To solve this dilemma, the authors suggested a novel anticoagulation strategy in pregnant women with prosthetic valves. Seventy-eight pregnancies of 65 women (median age 32 [27-35] years) were included in the study. A combination of LMWH and a reduced dose warfarin were associated with low rates of thrombus-related complications in pregnant patients with mechanical heart valves.


Assuntos
Anticoagulantes , Próteses Valvulares Cardíacas , Heparina de Baixo Peso Molecular , Complicações Cardiovasculares na Gravidez , Varfarina , Humanos , Feminino , Gravidez , Anticoagulantes/administração & dosagem , Adulto , Varfarina/administração & dosagem , Varfarina/efeitos adversos , Complicações Cardiovasculares na Gravidez/tratamento farmacológico , Heparina de Baixo Peso Molecular/administração & dosagem , Heparina de Baixo Peso Molecular/uso terapêutico , Heparina de Baixo Peso Molecular/efeitos adversos , Estudos Prospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Quimioterapia Combinada , Resultado da Gravidez , Primeiro Trimestre da Gravidez , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/epidemiologia , Trombose/prevenção & controle , Trombose/etiologia
2.
Echocardiography ; 36(9): 1783-1786, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31471980

RESUMO

Subvalvular pannus formation is a rare but clinically important complication with prosthetic valves. Transthoracic echocardiography still plays a role in the initial assessment of mechanical aortic valve dysfunction. But evaluation with transesophageal echocardiography is more useful. Subvalvular area may be a blind spot of echocardiography due to acoustic shadowing. The case presented herein underlines the significant role of transgastric plane and three-dimensional TEE in the assessment of subvalvular pannus formation in mechanical aortic valves.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Insuficiência da Valva Aórtica/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade
3.
Echocardiography ; 36(7): 1431-1433, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31260129

RESUMO

The mitral-aortic intervalvular fibrosa (MAIVF) is a fibrous, avascular region between the anterior leaflet of the mitral valve and noncoronary cusp of the aortic valve. This makes MAIVF vulnerable to injury and infection; thus pseudoaneurysm may develop. The pseudoaneurysm can cause compression to coronary arteries which causes angina or pulmonary artery resulting in pulmonary hypertension. We presented the pseudoaneurysm of MAIVF causing compression of superior vena cava and right atrium which was visualized by two- and three-dimensional transesophageal echocardiography and cardiac computed tomography.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Falso Aneurisma/patologia , Valva Aórtica/patologia , Diagnóstico Diferencial , Ecocardiografia , Átrios do Coração , Humanos , Masculino , Valva Mitral/patologia , Tomografia Computadorizada por Raios X , Veia Cava Superior
4.
Clin Transplant ; 32(7): e13273, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29923227

RESUMO

BACKGROUND: The aim of this study was to explore the role of oxidative stress index (OSI), myeloperoxidase (MPO), and catalase (CAT) activity in cardiac allograft vasculopathy (CAV) in heart transplant recipients (HTRs). METHODS: The study enrolled a median age of 41 ± 9 years 47 recipients. The HTx patients were divided into two groups based on the presence CAV as follows: CAV(+) and CAV(-) group. Also, CAV(+) group were divided into two groups as mild/moderate to severe CAV. The OSI, MPO, and CAT activity were analyzed in both groups. RESULTS: The mean total antioxidant capacity (0.79 ± 0.46 vs 1.03 ± 0.33 µmol H2 O2 equiv/L) P = .043 was significantly lower and OSI, MPO, CAT activity were significantly higher in CAV(+) group (63 ± 38 vs 20 ± 16 arbitrary unit, P = .001; 398 ± 242 vs 139  ± 112 µg/L, P = .001; 51 ± 42 vs 26 ± 23 pmol/mg protein, P = .013, respectively). Also, mean OSI (38 ± 41 vs 93 ± 75, P = .05) were significantly higher in severe CAV(+) group. Recipient age, male gender, and low density lipoprotein-cholesterol were significantly higher in CAV(+) group. There was a moderate correlation between the CAV grade and OSI, MPO, and CAT levels in univariate analysis (r = .560, P = .002; r = .643, P = .007; r = .681, P = .001, respectively). CONCLUSION: An increase in the serum level of OSI, MPO, and CAT was associated with CAV in HTRs.


Assuntos
Catalase/metabolismo , Transplante de Coração/efeitos adversos , Estresse Oxidativo , Peroxidase/metabolismo , Doenças Vasculares/diagnóstico , Adulto , Aloenxertos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Doenças Vasculares/etiologia , Doenças Vasculares/metabolismo
5.
Echocardiography ; 35(4): 559-562, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29420842

RESUMO

Ventricular septal rupture (VSR) is a rare but fatal complication of acute myocardial infarction (AMI) with an associated mortality that ranges from 41% to 80%. The treatment consists of supplemental oxygenation, afterload reduction, intraaortic balloon pump, and surgical repair. In selected patients, extracorporeal membrane oxygenation (ECMO) and/or percutaneous closure of the defect can be considered if anatomically appropriate. Echocardiography evaluates the morphology and location of the defect, anatomical concerns for percutaneous closure, and accompanying pathologies. We present a 48-year-old man with inferior myocardial infarction and basal VSR who was not a candidate for percutaneous closure. Surgery was planned, but he died from extensive subarachnoid and intracranial hemorrhage.


Assuntos
Hemorragias Intracranianas/complicações , Hemorragias Intracranianas/diagnóstico por imagem , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Ruptura do Septo Ventricular/complicações , Ruptura do Septo Ventricular/diagnóstico por imagem , Doença Aguda , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Tomografia Computadorizada por Raios X
6.
Artigo em Inglês | MEDLINE | ID: mdl-28247524

RESUMO

BACKGROUND: Arsenic exposure is associated with various cardiovascular diseases. The aim of the present study was to assess cardiac autonomic function via heart rate response to exercise and recovery period of treadmill testing in arsenic-exposed workers. METHODS: Sixty-five (65) occupationally arsenic-exposed workers and 35 healthy controls were enrolled. Blood and urinary arsenic levels were analyzed and symptom limited maximal treadmill exercise test were performed. Chronotropic response to exercise including age-predicted maximal heart rate (APMHR), heart rate reserve (HRreserve ), age-predicted HRreserve (APHRreserve ) and adjusted HRreserve and 1st-, 2nd-and 3rd-min heart rate recovery (HRR) indices were calculated. RESULTS: Baseline clinical and echocardiographic parameters, exercise test duration, resting and maximal heart rate, peak exercise capacity, HRreserve , APMHR, APHRreserve , and adjusted HRreserve were found to be similar between groups. HRR1 (22.0 ± 4.3 vs. 24.3 ± 3.1 bpm, p = .003) and HRR2 (43.2 ± 6.2 vs. 46.7 ± 6.4 bpm, p = .012) were significantly lower in arsenic-exposed workers compared to controls. Blood and urinary arsenic levels negatively correlated with HRR1 (r = -.477, p < .001 and r = -.438, p < .001, respectively) and HRR2 (r = -.507, p < .001 and r = -.412, p < .001 respectively). CONCLUSIONS: Arsenic-exposed workers had lower HRR indices than normal subjects but chronotropic response were similar. Cardiac autonomic dysregulation may be one of the cardiovascular consequences of arsenic exposure.


Assuntos
Intoxicação por Arsênico/fisiopatologia , Doenças Cardiovasculares/induzido quimicamente , Eletrocardiografia/métodos , Teste de Esforço/métodos , Frequência Cardíaca/fisiologia , Adulto , Arsênio , Estudos Transversais , Eletrocardiografia/estatística & dados numéricos , Exercício Físico , Teste de Esforço/estatística & dados numéricos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Recuperação de Função Fisiológica
7.
J Thromb Thrombolysis ; 42(3): 399-404, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27085540

RESUMO

Atrial fibrillation (AF) is a common cardiac arrhythmia. Dabigatran etixalate (DE) is one of the new oral anticoagulant drugs being used in nonvalvular AF (NVAF). There is no adequate real world data in different populations about DE. The aim of this registry was to evaluate the efficacy and safety of DE Consecutive NVAF patients treated with warfarin or both DE doses were enrolled during 18 months study period. The patients were re-evaluated at regular 6-month intervals during the follow-up period. During the follow-up period outcomes were documented according to RELY methodology A total of 555 patients were analyzed. There was no significant difference in ischemic stroke rates (p = 0.73), death rates (p = 0.15) and MI rates (p = 0.56) between groups. The rate of major bleeding was significantly higher in warfarin and dabigatran 150 mg group than dabigatran 110 mg (p < 0.001). Intracranial bleeding rate and relative risk were significantly lower in dabigatran 110 mg group than warfarin group (p = 0.004). Dyspepsia was significantly higher in both DE doses than warfarin (p = 0.004) Both DE doses are as effective as warfarin in reducing stroke rates in NVAF patients, without increasing MI rates. Intracranial bleeding rates are significantly lower in warfarin than both doses of DE and gastrointestinal bleeding risk increases with increased DE doses.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Dabigatrana/farmacologia , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacologia , Fibrilação Atrial/complicações , Dabigatrana/administração & dosagem , Dispepsia , Feminino , Seguimentos , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Hemorragias Intracranianas/induzido quimicamente , Masculino , Infarto do Miocárdio , Sistema de Registros , Acidente Vascular Cerebral/prevenção & controle , Varfarina/administração & dosagem , Varfarina/farmacologia
8.
Scand Cardiovasc J ; 50(1): 23-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26507385

RESUMO

OBJECTIVES: The crucial role of twisting motion on both left ventricular (LV) contraction and relaxation has been clearly identified. However, the reports studying the association between LV torsion and loading conditions have revealed conflicting outcomes. Previously normal saline infusion was shown to increase LV rotation. Our aim was to test this phenomenon after volume depletion in healthy volunteer blood donors. DESIGN: A total of 26 healthy male volunteers were included in the study. LV end-diastolic and end-systolic diameter, LV ejection fraction, LV diastolic parameters, LV apical and basal rotation and peak systolic LV torsion were measured by speckle-tracking echocardiography before and after 450 mL blood donation. RESULTS: Blood donation led to a significant decrease in end-diastolic LV internal diameter (48.7 ± 0.4 versus 46.4 ± 0.4 mm; p < 0.001) and cardiac output (6.2 ± 1.0 versus 5.1 ± 0.7 L/min; p < 0.001). There was a significant decrease in the magnitude of peak systolic apical rotation (4.4 ± 1.9° versus 2.9 ± 1.5°; p < 0.001) but no change in basal rotation (2.6 ± 1.4° versus 2.7 ± 1.6°; p = 0.81). Peak systolic LV Torsion decreased after blood donation (6.9 ± 1.9° versus 5.7 ± 2.1°; p = 0.028). CONCLUSIONS: LV apical rotation and peak systolic LV torsion seem to be preload dependent. Preload reduction provided by 450-mL blood donation decreased LV torsion in healthy male volunteers. Volume dynamics should be taken into account in the evaluation of LV torsion.


Assuntos
Doadores de Sangue , Volume Sanguíneo , Contração Miocárdica , Função Ventricular Esquerda , Adaptação Fisiológica , Adulto , Fenômenos Biomecânicos , Diástole , Ecocardiografia Doppler de Pulso , Voluntários Saudáveis , Humanos , Masculino , Volume Sistólico , Sístole , Fatores de Tempo , Torção Mecânica
9.
Heart Lung Circ ; 25(2): 160-5, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26412487

RESUMO

BACKGROUND: Coeliac disease (CD) is an autoimmune and inflammatory disorder of the small intestine. There is reasonable evidence linking inflammation to the initiation and continuation of atrial fibrillation (AF) in inflammatory conditions. Atrial electro-mechanic delay (EMD) was suggested as an early marker of AF in previous studies. The objectives of this study were to evaluate atrial electromechanical properties measured by tissue Doppler imaging and simultaneous electrocardiography (ECG) tracing in patients with CD. METHODS: Thirty-nine patients with coeliac disease (CD), and 26 healthy volunteers, matched for age and sex, were enrolled in the study. Atrial electromechanical properties were measured by using transthoracic echocardiography and surface ECG. Interatrial electro-mechanic delay (EMD), left intraatrial EMD, right intratrial EMD were calculated. RESULTS: There was no difference between CD patients and healthy volunteers in terms of basal characteristics. Patients with CD had significantly prolonged left and right intraatrial EMDs, and interatrial EMD compared to healthy controls (p= 0.03, p= 0.02, p<0.0001, respectively). Interatrial EMD was positively correlated with age, disease duration, anti-gliadin IgG, anti-endomysium and disease status. In multiple linear regression, interatrial EMD was independently associated with disease duration, anti-endomysium and disease status after adjusting for age and sex. CONCLUSIONS: In the present study, atrial EMDs were found significantly higher in patients with CD compared with healthy individuals. Measurement of atrial EMD parameters might be used to predict the risk of development of AF in patients with CD.


Assuntos
Fibrilação Atrial/fisiopatologia , Doença Celíaca/fisiopatologia , Átrios do Coração/fisiopatologia , Adulto , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Doença Celíaca/sangue , Doença Celíaca/complicações , Doença Celíaca/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Doppler em Cores , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
10.
Med Princ Pract ; 25(4): 343-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26964065

RESUMO

OBJECTIVE: The aim of this study was to assess exercise heart rate recovery (HRR) indices in mercury-exposed individuals when evaluating their cardiac autonomic function. SUBJECTS AND METHODS: Twenty-eight mercury-exposed individuals and 28 healthy controls were enrolled. All the subjects underwent exercise testing and transthoracic echocardiography. The HRR indices were calculated by subtracting the first- (HRR1), second- (HRR2) and third-minute (HRR3) heart rates from the maximal heart rate. The two groups were evaluated in terms of exercise test parameters, especially HRR, and a correlation analysis was performed between blood, 24-hour urine and hair mercury levels and the test parameters. RESULTS: The mercury-exposed and control groups were similar in age (37.2 ± 6.6 vs. 36.9 ± 9.0 years), had an identical gender distribution (16 females and 12 males) and similar left ventricular ejection fractions (65.5 ± 3.1 vs. 65.4 ± 3.1%). The mean HRR1 [25.6 ± 6.5 vs. 30.3 ± 8.2 beats per min (bpm); p = 0.009], HRR2 (43.5 ± 5.3 vs. 47.8 ± 5.5 bpm; p = 0.010) and HRR3 (56.8 ± 5.1 vs. 59.4 ± 6.3 bpm; p = 0.016) values were significantly lower in the mercury-exposed group than in the healthy controls. However, there were no significant correlations between blood, urine and hair mercury levels and exercise test parameters. CONCLUSIONS: Mercury-exposed individuals had lower HRR indices than normal subjects. In these individuals, mercury exposure measurements did not show correlations with the exercise test parameters, but age did show a negative correlation with these parameters. Therefore, cardiac autonomic functions might be involved in cases of mercury exposure.


Assuntos
Sistema Nervoso Autônomo/efeitos dos fármacos , Sistema Nervoso Autônomo/fisiopatologia , Coração/efeitos dos fármacos , Coração/fisiopatologia , Intoxicação por Mercúrio/fisiopatologia , Adulto , Pressão Sanguínea , Estudos Transversais , Ecocardiografia , Exercício Físico/fisiologia , Teste de Esforço , Feminino , Cabelo/química , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Mercúrio/análise , Pessoa de Meia-Idade
11.
Echocardiography ; 32(10): 1498-503, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25735868

RESUMO

OBJECTIVES: Epicardial adipose tissue (EAT) and atrial electromechanical delay (AEMD) have been shown to be closely linked with atrial fibrillation. In this study, we aimed to investigate the relationship between EAT and AEMD. METHODS: Ninety-six patients were included in this study. Echocardiographic measurements were performed, and laboratory parameters were recorded. Patients were divided into two groups according to their inter-AEMD values. Patients with an inter-AEMD value of <42.6 msec formed group 1 and patients with an inter-AEMD value of ≥42.6 msec formed group 2. RESULTS: The EAT thickness (3.7 ± 1.2 vs. 5.0 ± 1.6, P < 0.001) and LAVI (20.4 ± 2.9 vs. 24.5 ± 6.7, P = 0.001) were significantly higher in group 2. There was a significant positive correlation between AEMD parameters with EAT and LAVI. After multivariate logistic regression analysis, EAT (OR: 1.505; 95% CI: 1.056-2.143, P = 0.023) and LAVI (OR: 1.140; 95% CI: 1.018-1.277, P = 0.023) were found as independent predictors of prolonged AEMD. CONCLUSIONS: We found that EAT thickness was closely related with AEMD, and we also found that EAT and LAVI were independent predictors of prolonged AEMD. These findings may be helpful to explain some pathogenic mechanisms in the development of AF.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Hipertensão/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Eletrocardiografia , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco
12.
Turk Kardiyol Dern Ars ; 43(3): 250-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25905996

RESUMO

OBJECTIVE: The aim of this study was to evaluate acute cardiac remodeling after transcatheter closure of atrial septal defect (ASD) in adult patients. METHODS: This study included 19 patients (40.0 ± 13.51 mean age) with secundum ASD who underwent successful transcatheter closure. All patients received routine transthoracic echocardiography, including tissue Doppler left ventricle (LV) and right ventricle (RV) myocardial performance indices (MPI), mitral annular plane systolic excursion (MAPSE) and tricuspid annular plane systolic excursion (TAPSE) before ASD closure, on first day, and at first and third months after closure. RESULTS: Left ventricle end-diastolic diameter (LVEDD) increased (37 ± 4 mm to 44 ± 5 mm, p<0.001); RVEDD decreased markedly after closure (40 ± 4 mm to 32 ± 5 mm, p<0.001); and differences existed in LV and RV adaptation. While MAPSE (1.87 ± 0.22 cm to 2.01 ± 0.23 cm, p<0.001) and LVMPI improved soon after procedure (0.44 ± 0.04 to 0.36 ± 0.03, p<0.001), RVMPI worsened until the first month post-procedure (0.25 ± 0.02 to 0.31 ± 0.03, p<0.001), but recovered by the third month follow-up visit (0.31 ± 0.03 to 0.27 ± 0.02, p<0.001). TAPSE remained unchanged (2.49 ± 0.46 cm to 2.51 ± 0.32 cm, p=0.078). CONCLUSION: Closure of ASD using the Amplatzer Septal Occluder device led to a decrease in RV size and an increase in LV size. In the early period, while LV function improved, RV function deteriorated, probably due to RV functional and anatomical differences.


Assuntos
Comunicação Interatrial/patologia , Comunicação Interatrial/cirurgia , Intervenção Coronária Percutânea/métodos , Remodelação Ventricular , Adulto , Estudos de Coortes , Ecocardiografia Doppler , Feminino , Comunicação Interatrial/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos
13.
Turk Kardiyol Dern Ars ; 42(4): 332-8, 2014 Jun.
Artigo em Turco | MEDLINE | ID: mdl-24899476

RESUMO

OBJECTIVES: Coronary artery fistula is an infrequent malformation, and the prevalence was reported as approximately 0.1-0.4% in previous studies. However, the number of studies about microfistulas from coronary arteries to the left ventricle is inadequate, especially in the Turkish population. The purpose of this study was to evaluate the prevalence and clinical features of microfistulas in subjects undergoing coronary angiography for the assessment of coronary artery disease. STUDY DESIGN: In this retrospective study, we researched the cardiac catheterization laboratory database between January 2008 and July 2013. The presence of microfistulas was established according to the following criteria: 1) direct filling of the heart cavity during selective coronary injection without interposing "capillary" phase or venous filling, and 2) visualization of small vessels interposed between the epicardial coronary vessels and the heart cavity and emptying into the heart. RESULTS: Microfistulas were found in 12 (0.11%) of the 11403 coronary angiographies. There were 7 (58.3%) female patients (mean age, 70.2±10.8 years), and contemporary severe coronary artery stenosis was noted in 2 (16.7%) patients. Chest pain was the most frequently encountered complaint, followed by dyspnea. Microfistulas originated from the left anterior descending artery (100%), circumflex artery (66.7%), and right coronary artery (58.3%). In addition, multiple microfistulas were seen in 6 (50%) patients, bilateral microfistulas in 3 (25%) patients and unilateral microfistula in 3 (25%) patients, and all of them terminated in the left ventricle. CONCLUSION: Our study found an overall incidence of microfistulas of 0.11%. Microfistula is a rare cardiac anomaly that sometimes causes cardiac symptoms; otherwise, it is detected during routine coronary angiography.


Assuntos
Anomalias dos Vasos Coronários/epidemiologia , Ventrículos do Coração/anormalidades , Fístula Vascular/epidemiologia , Idoso , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/terapia , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Humanos , Incidência , Masculino , Prevalência , Estudos Retrospectivos , Turquia/epidemiologia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/terapia
14.
Blood Coagul Fibrinolysis ; 32(8): 607-610, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387218

RESUMO

Protein-C deficiency causes a thrombophilic environment in circulation. Although venous thromboembolism is the most common presentation, arterial events are rare. A 45 year-old woman with protein-C deficiency presented with multiple thromboembolic events including bilateral renal infarct and inferior ST-elevation myocardial infarction 3-days after coronary angiography via femoral approach which were normal coronary arteries. Computed tomographic angiography and transesophageal echocardioraphy displayed multiple thrombi sources including left atrium, left subclavian artery, sinus valsalva and descending aorta. Unfractionated-heparin and tissue plasminogen activator infusion were given. Although regression in ST-segment elevation and chest pain, no reduction in sizes of left atrial and aortic thrombus was observed by imaging modality. The patient refused surgical removal of thrombi, then warfarin therapy was planned. In patients with congenital thrombophilia and history of thromboembolism, anticoagulant treatment should be carefully managed during percutaneous diagnostic and interventional treatments and they should be performed by radial approach without interruption of anticoagulants.


Assuntos
Embolia , Trombose , Tromboembolia Venosa , Anticoagulantes/uso terapêutico , Feminino , Humanos , Pessoa de Meia-Idade , Trombose/complicações , Ativador de Plasminogênio Tecidual
15.
Biomark Med ; 15(13): 1131-1142, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34402630

RESUMO

Aim: We sought to determine the relationship between presence of atrial fibrillation (AF) and serum biomarkers, including native thiol (antioxidant), disulphide/native thiol ratio, Hs-CRP and high-sensitivity Troponin-I (Hs-TnI) in hypertrophic cardiomyopathy (HCM). Materials & methods: We enrolled consecutive 121 HCM outpatients without AF and 40 HCM outpatients with AF. A 12-lead electrocardiogram, transthoracic echocardiography and 24/48-h ambulatory rhythm monitoring were performed for all patients. Fasting venous blood samples were taken from all study patients to measure serum thiol-disulphide homeostasis, Hs-CRP and Hs-TnI. Results: Serum-native thiol was lower and disulphide/native thiol ratio was more oxidized in HCM patients with AF (p < 0.001). Also, HCM patients with AF had higher Hs-TnI and Hs-CRP than no-AF HCM patients. Disulphide/native thiol ratio, serum-native thiol, age, NYHA functional class≥III, and advanced diastolic dysfunction were independently associated with the presence of AF in HCM. Conclusion: In addition to clinical and echocardiographic findings, oxidative stress is also associated with AF in HCM patients.


Assuntos
Fibrilação Atrial/complicações , Biomarcadores/sangue , Cardiomiopatia Hipertrófica/diagnóstico , Ecocardiografia/métodos , Eletrocardiografia/métodos , Adulto , Fibrilação Atrial/fisiopatologia , Proteína C-Reativa/análise , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/fisiopatologia , Dissulfetos/sangue , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Nomogramas , Compostos de Sulfidrila/sangue , Troponina I/sangue
16.
Int J Cardiovasc Imaging ; 37(9): 2691-2705, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33835319

RESUMO

Three-dimensional transesophageal echocardiography (3D-TEE) provides detailed images of prosthetic valve thrombosis (PVT). However, data regarding PVT localization patterns based on 3D-TEE and their association with clinical findings among various bileaflet mitral prosthetic valve brands is lacking. The locations of thrombi were classified into 4 groups according to hinge and annulus involvement based on 3D-TEE: ring-like PVT involving entire mitral annulus (type-1), PVT involving peri-hinge(s) region and extends through some part of the annulus (type-2), PVT involving mitral annulus without involving hinge(s) region (type-3), and PVT involving only (peri)hinge(s) area (type-4). This study was conducted in 265 patients (male: 71, mean age: 46.3 ± 12.7 years) with mitral PVT, including 150 St Jude Medical (SJM), 65 Carbomedics, 29 Medtronic ATS open-pivot, and 21 Sorin bileaflet mechanical valves. There was a significant difference in most common PVT localization patterns between different prosthetic valves (type-1 for Carbomedics and Sorin; type-2 for SJM and type-3 for ATS valves; p < 0.001). Additionally, PVT involving only (peri)hinge region(s) (type-4) was mostly observed in patients with SJM valves (18%). (Peri)hinge(s) area involvement was observed in the majority of study patients (78.1%). In patients who presented with thromboembolism, the most common PVT localization pattern was type-1 (53%). Increased age, low international normalized ratio on admission, PVT with a mobile part > 2 mm, type-1 and type-4 PVT were associated with thromboembolic events. In conclusion, thrombus can be displayed in distinct locations in several types of bileaflet mechanical valves due to different design, hinge and pivot mechanisms, which can be complicated with thromboembolic events.


Assuntos
Próteses Valvulares Cardíacas , Tromboembolia , Trombose , Ecocardiografia Transesofagiana , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valor Preditivo dos Testes , Desenho de Prótese , Tromboembolia/diagnóstico por imagem , Tromboembolia/etiologia , Trombose/diagnóstico por imagem , Trombose/etiologia
17.
Turk Kardiyol Dern Ars ; 49(7): 568-578, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34623300

RESUMO

OBJECTIVE: In this study, we aimed to report early outcomes of catheter-directed thrombolysis (CDT) with alteplase in patients with subacute limb ischemia and to assess whether there is a link between malnutrition (determined by Controlling Nutritional Status [CONUT] score) and response to thrombolysis and bleeding. METHODS: This was a retrospective study conducted between 2007 and 2020 with 118 patients with Rutherford class 3 (34.7%), class 4 (40.7%), and class 5 (24.6%) symptoms owing to infraaortic subacute thrombotic occlusion who were treated with catheter-directed thrombolysis. RESULTS: Immediate technical success (Thrombolysis in Myocardial Infarction [TIMI] grade 2/3) was achieved in 56%, overall technical success after all adjunctive procedures was seen in 83.9%. Clinical success was obtained in 74.5% within 30 days. Major bleeding occurred in 11.8%. When we excluded access site hematomas, the rate of major bleeding was 5.1%. In-hospital mortality rate was 5.1%, and the amputation rate within 30 days was 12.7%. Any-degree malnutrition was detected in 48.3% according to CONUT score (≥2). Any-degree malnutrition was associated with failed thrombolysis and bleeding. The CONUT score predicted insufficient lytic response even after adjustment for confounding factors; however, serum C-reactive protein or neutrophil/lenfosit ratio did not. Other predictors of immediate technical failure after thrombolysis were symptom duration, Rutherford class 4/5 symptoms, and worsened distal runoff. CONCLUSION: In patients with subacute limb ischemia, CDT combined with adjunctive interventions was effective in many patients at the expense of a substantial risk of bleeding and death. Malnutrition was associated with insufficient lytic response and bleeding. Physicians should be aware of malnutrition and consider the nutritional status of patients with limb ischemia when selecting appropriate treatment.


Assuntos
Fibrinolíticos/uso terapêutico , Desnutrição , Doença Arterial Periférica/tratamento farmacológico , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Idoso , Cateterismo Periférico , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Extremidade Inferior/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estado Nutricional , Doença Arterial Periférica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Terapia Trombolítica , Trombose/diagnóstico por imagem , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento
18.
Turk Kardiyol Dern Ars ; 48(5): 539-544, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32633263

RESUMO

Prosthetic valve thrombosis (PVT) is a life-threatening valve dysfunction. In asymptomatic cases, as well as certain symptomatic patients with PVT, the results of the first-line imaging tool, transthoracic echocardiography, may be inconclusive in terms of illustrating the thrombus, which is necessary in order to select the proper treatment option. Hence, a differential diagnosis based on clinical presentation may be challenging, and multimodality imaging, including echocardiography, cine fluoroscopy, and cardiac computed tomography, is usually required to distinguish between PVT and other prosthesis-related pathologies, such as pannus, vegetation, and prosthesis-patient mismatch.


Assuntos
Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Valva Mitral/diagnóstico por imagem , Imagem Multimodal/métodos , Trombose/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Falha de Prótese/etiologia , Tomografia Computadorizada por Raios X
19.
Braz J Otorhinolaryngol ; 83(1): 45-49, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27133905

RESUMO

INTRODUCTION: Epistaxis and hypertension are frequent conditions in the adult population. Masked hypertension is defined as a clinical condition in which a patient's office blood pressure level is <140/90mmHg, but the ambulatory or home blood pressure readings are in the hypertensive range. Many studies have proved that hypertension is one of the most important causes of epistaxis. The prevalence of this condition in patients with epistaxis is not well defined. OBJECTIVE: This study aimed to evaluate the prevalence of masked hypertension using the results of office blood pressure measurement compared with the results of ambulatory blood pressure monitoring. METHODS: Sixty patients with epistaxis and 60 control subjects were enrolled in the study. All patients with epistaxis and controls without history of hypertension underwent physical examination, including office blood pressure measurement, ambulatory or home blood pressure, and measurement of anthropometric parameters. RESULTS: Mean age was similar between the epistaxis group and the controls - 21-68 years (mean 42.9) for the epistaxis group and 18-71 years (mean 42.2) for the control group. A total of 20 patients (33.3%) in the epistaxis group and 7 patients (11.7%) in the control group (p=0.004) had masked hypertension. Night-time systolic blood pressure was significantly higher in patients with epistaxis than in the control group (p<0.005). However, no significant difference was found in daytime systolic blood pressure between the control group and the patients with epistaxis (p=0.517). CONCLUSION: This study demonstrates increased masked hypertension prevalence in patients with epistaxis. We suggest that all patients with epistaxis should undergo ambulatory or home blood pressure to detect masked hypertension, which could be a possible cause of epistaxis.


Assuntos
Epistaxe/etiologia , Hipertensão Mascarada/complicações , Adolescente , Adulto , Idoso , Monitorização Ambulatorial da Pressão Arterial , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Hipertensão Mascarada/diagnóstico , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Adulto Jovem
20.
Turk Kardiyol Dern Ars ; 44(5): 371-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27439922

RESUMO

OBJECTIVE: The aim of the present study was to assess cardiac autonomic function via indices of exercise heart rate recovery (HRR) in workers occupationally exposed to lead. METHODS: A total of 98 lead-exposed workers and 98 healthy controls were enrolled. All underwent exercise testing and transthoracic echocardiography. HRR indices were calculated by subtracting 1st- (HRR1), 2nd- (HRR2), and 3rd-minute (HRR3) heart rates from maximal heart rate (HR). Exercise test parameters- HRR in particular- were compared between groups, and correlation analysis of blood, 24-hour urine lead levels, and test parameters was performed. RESULTS: Baseline demographic and clinical characteristics were found to be similar between groups. Mean HRR1 (26.2±3.6 vs 29.0±4.1 bpm, p<0.001), HRR2 (42.6±3.9 vs 46.9±3.7 bpm, p<0.001), and HRR3 (56.6±4.5 vs 61.8±4.3 bpm, p<0.001) values were significantly lower in the lead-exposed group than in the healthy controls. HRR1 was found to be significantly correlated with blood (r:-0.415; p<0.001) and 24-hour urine lead levels (r:-0.446; p<0.001). HRR2 and HRR3 were significantly correlated with 24-hour urine lead level (r:-0.396; p<0.001 and r:-0.233; p=0.021, respectively). CONCLUSION: Lead-exposed workers had lower HRR indices than normal subjects. Blood and 24-hour urine lead levels were significantly associated with HRR indices. Cardiac autonomic functions may be affected by exposure to lead, and those occupationally exposed should be closely followed for adverse cardiovascular outcome.


Assuntos
Exercício Físico/fisiologia , Frequência Cardíaca/fisiologia , Chumbo/sangue , Chumbo/urina , Exposição Ocupacional/análise , Adulto , Estudos Transversais , Humanos , Chumbo/toxicidade , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa