Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Anal Chem ; 95(13): 5532-5541, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36947869

RESUMO

There has been a continuous effort to fabricate a fast, sensitive, and inexpensive system for influenza virus detection to meet the demand for effective screening in point-of-care testing. Herein, we report a sialic acid (SA)-conjugated graphene field-effect transistor (SA-GFET) sensor designed using α2,3-linked sialic acid (3'-SA) and α2,6-linked sialic acid (6'-SA) for the detection and discrimination of the hemagglutinin (HA) protein of the H5N2 and H1N1 viruses. 3'-SA and 6'-SA specific for H5 and H1 influenza were used in the SA-GFET to capture the HA protein of the influenza virus. The net charge of the captured viral sample led to a change in the electrical current of the SA-GFET platform, which could be correlated to the concentration of the viral sample. This SA-GFET platform exhibited a highly sensitive response in the range of 101-106 pfu mL-1, with a limit of detection (LOD) of 101 pfu mL-1 in buffer solution and a response time of approximately 10 s. The selectivity of the SA-GFET platform for the H1N1 and H5N2 influenza viruses was verified by testing analogous respiratory viruses, i.e., influenza B and the spike protein of SARS-CoV-2 and MERS-CoV, on the SA-GFET. Overall, the results demonstrate that the developed dual-channel SA-GFET platform can potentially serve as a highly efficient and sensitive sensing platform for the rapid detection of infectious diseases.


Assuntos
COVID-19 , Grafite , Vírus da Influenza A Subtipo H1N1 , Vírus da Influenza A Subtipo H5N2 , Vírus da Influenza A , Influenza Humana , Humanos , Vírus da Influenza A/metabolismo , Ácido N-Acetilneuramínico/metabolismo , Vírus da Influenza A Subtipo H1N1/metabolismo , Grafite/metabolismo , Vírus da Influenza A Subtipo H5N2/metabolismo , Receptores Virais/metabolismo , SARS-CoV-2/metabolismo , Hemaglutininas/metabolismo , Glicoproteínas de Hemaglutininação de Vírus da Influenza
2.
Arch Virol ; 167(3): 871-879, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35137250

RESUMO

Coronavirus disease 2019 (COVID-19) is an acute respiratory infection caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Other coronaviruses (CoVs) can also infect humans, although the majority cause only mild respiratory symptoms. Because early diagnosis of SARS-CoV-2 is critical for preventing further transmission events and improving clinical outcomes, it is important to be able to distinguish SARS-CoV-2 from other SARS-related CoVs in respiratory samples. Therefore, we developed and evaluated a novel reverse transcription quantitative polymerase chain reaction (RT-qPCR) assay targeting the genes encoding the spike (S) and membrane (M) proteins to enable the rapid identification of SARS-CoV-2, including several new circulating variants and other emerging SARS-like CoVs. By analysis of in vitro-transcribed mRNA, we established multiplex RT-qPCR assays capable of detecting 5 × 10° copies/reaction. Using RNA extracted from cell culture supernatants, our multiple simultaneous SARS-CoV-2 assays had a limit of detection of 1 × 10° TCID50/mL and showed no cross-reaction with human CoVs or other respiratory viruses. We also validated our method using human clinical samples from patients with COVID-19 and healthy individuals, including nasal swab and sputum samples. This novel one-step multiplex RT-qPCR assay can be used to improve the laboratory diagnosis of human-pathogenic CoVs, including SARS-CoV-2, and may be useful for the identification of other SARS-like CoVs of zoonotic origin.


Assuntos
COVID-19 , COVID-19/diagnóstico , Técnicas de Laboratório Clínico , Estudos de Viabilidade , Humanos , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/genética , Sensibilidade e Especificidade
3.
Chem Eng J ; 444: 136460, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-35463870

RESUMO

Most respiratory masks are made of fabrics, which only capture the infectious virus carriers into the matrix. However, these contagious viruses stay active for a long duration (∼7 days) within the fabric matrix possibly inducing post-contact transmissions. Moreover, conventional masks are vulnerable to bacterial growth with prolonged exposure to exhaled breaths. Herein, we combined violacein, a naturally-occurring antimicrobial agent, with porous nanofiber membranes to develop a series of functional filters that autonomously sterilizes viruses and bacteria. The violacein-embedded membrane inactivates viruses within 4 h (99.532 % reduction for influenza and 99.999 % for human coronavirus) and bacteria within 2 h (75.5 % reduction). Besides, its nanofiber structure physically filters out the nanoscale (<0.8 µm) and micron-scale (0.8 µm - 3 µm) particulates, providing high filtration efficiencies (99.7 % and 100 % for PM 1.0 and PM 10, respectively) with long-term stability (for 25 days). In addition, violacein provides additional UV-resistant property, which protects the skin from sunlight. The violacein-embedded membrane not only proved the sterile efficacy of microbe extracted pigments for biomedical products but also provided insights to advance the personal protective equipment (PPE) to fight against contagious pathogens.

4.
Korean J Parasitol ; 56(1): 61-70, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29529852

RESUMO

We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Kit de Reagentes para Diagnóstico , Proteínas do Envelope Viral/imunologia , Proteínas não Estruturais Virais/imunologia , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia , Zika virus/imunologia , Reações Cruzadas , Vírus da Dengue , Humanos , Sensibilidade e Especificidade
5.
Electrophoresis ; 36(7-8): 994-1001, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25641332

RESUMO

We developed the photo-crosslinkable hydrogel-based 3D microfluidic device to culture neural stem cells (NSCs) and tumors. The photo-crosslinkable gelatin methacrylate (GelMA) polymer was used as a physical barrier in the microfluidic device and collagen type I gel was employed to culture NSCs in a 3D manner. We demonstrated that the pore size was inversely proportional to concentrations of GelMA hydrogels, showing the pore sizes of 5 and 25 w/v% GelMA hydrogels were 34 and 4 µm, respectively. It also revealed that the morphology of pores in 5 w/v% GelMA hydrogels was elliptical shape, whereas we observed circular-shaped pores in 25 w/v% GelMA hydrogels. To culture NSCs and tumors in the 3D microfluidic device, we investigated the molecular diffusion properties across GelMA hydrogels, indicating that 25 w/v% GelMA hydrogels inhibited the molecular diffusion for 6 days in the 3D microfluidic device. In contrast, the chemicals were diffused in 5 w/v% GelMA hydrogels. Finally, we cultured NSCs and tumors in the hydrogel-based 3D microfluidic device, showing that 53-75% NSCs differentiated into neurons, while tumors were cultured in the collagen gels. Therefore, this photo-crosslinkable hydrogel-based 3D microfluidic culture device could be a potentially powerful tool for regenerative tissue engineering applications.


Assuntos
Hidrogéis/química , Dispositivos Lab-On-A-Chip , Células-Tronco Neurais/citologia , Técnicas de Cultura de Tecidos/instrumentação , Técnicas de Cultura de Tecidos/métodos , Colágeno Tipo I/química , Reagentes de Ligações Cruzadas/química , Gelatina/química , Humanos , Células MCF-7 , Células-Tronco Neurais/fisiologia , Porosidade
6.
ACS Nano ; 18(2): 1371-1380, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38060408

RESUMO

Respiratory masks are the primary and most effective means of protecting individuals from airborne hazards such as droplets and particulate matter during public engagements. However, conventional electrostatically charged melt-blown microfiber masks typically require thick and dense membranes to achieve high filtration efficiency, which in turn cause a significant pressure drop and reduce breathability. In this study, we have developed a multielectrospinning system to address this issue by manipulating the pore structure of nanofiber networks, including the use of uniaxially aligned nanofibers created via an electric-field-guided electrospinning apparatus. In contrast to the common randomly collected microfiber membranes, partially aligned dual-nanofiber membranes, which are fabricated via electrospinning of a random 150 nm nanofiber base layer and a uniaxially aligned 450 nm nanofiber spacer layer on a roll-to-roll collector, offer an efficient way to modulate nanofiber membrane pore structures. Notably, the dual-nanofiber configuration with submicron pore structure exhibits increased fiber density and decreased volume density, resulting in an enhanced filtration efficiency of over 97% and a 50% reduction in pressure drop. This leads to the highest quality factor of 0.0781. Moreover, the submicron pore structure within the nanofiber networks introduces an additional sieving filtration mechanism, ensuring superior filtration efficiency under highly humid conditions and even after washing with a 70% ethanol solution. The nanofiber mask provides a sustainable solution for safeguarding the human respiratory system, as it effectively filters and inactivates human coronaviruses while utilizing 130 times fewer polymeric materials than melt-blown filters. This reusability of our filters and their minimum usage of polymeric materials would significantly reduce plastic waste for a sustainable global society.


Assuntos
Filtros de Ar , Nanofibras , Humanos , Nanofibras/química , Filtração , Polímeros
7.
J Nanosci Nanotechnol ; 13(3): 1820-3, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23755598

RESUMO

Magnetic nanoparticles and fluorescent quantum dots (QDs) can make many effective applications in biomedical system. Here, we demonstrated one way of synthetic method and its surface modification to use for biomedical applications. Fe3O4 nanoparticles are well known as magnetic materials and its magnetic property can be used in magnetic resonance imaging (MRI), cell detection. QDs as a fluorescent probes, make cell labeling and in vivo imaging possible. ZnS/AgInS2 QDs have a lower toxicity than other QDs (CdSe, CdTe, CdS). We combined two nanoparticles by hydrophobic interaction in their ligands. The prepared fluorescent magnetic composite particles were modified with CTAB-TEOS. The surface modified composite has a low cytotoxicity and these biocompatible particles will provide many possibilities in biomedical system.

8.
ACS Nano ; 16(11): 19451-19463, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36374248

RESUMO

The massive production of polymer-based respiratory masks during the COVID-19 pandemic has rekindled the issue of environmental pollution from nonrecyclable plastic waste. To mitigate this problem, conventional filters should be redesigned with improved filtration performance over the entire operational life while also being naturally degradable at the end. Herein, we developed a functional and biodegradable polymeric filter membrane consisting of a polybutylene adipate terephthalate (PBAT) matrix blended with cetyltrimethylammonium bromide (CTAB) and montmorillonite (MMT) clay, whose surface properties have been modified through cation exchange reactions for good miscibility with PBAT in an organic solvent. Particularly, the spontaneous evolution of a partial core-shell structure (i.e., PBAT core encased by CTAB-MMT shell) during the electrospinning process amplified the triboelectric effect as well as the antibacterial/antiviral activity that was not observed in naive PBAT. Unlike the conventional face mask filter that relies on the electrostatic adsorption mechanism, which deteriorates over time and/or due to external environmental factors, the PBAT@CTAB-MMT nanofiber membrane (NFM)-based filter continuously retains electrostatic charges on the surface due to the triboelectric effect of CTAB-MMT. As a result, the PBAT@CTAB-MMT NFM-based filter showed high filtration efficiencies (98.3%, PM0.3) even at a low differential pressure of 40 Pa or less over its lifetime. Altogether, we not only propose an effective and practical solution to improve the performance of filter membranes while minimizing their environmental footprint but also provide valuable insight into the synergetic functionalities of organic-inorganic hybrid materials for applications beyond filter membranes.


Assuntos
COVID-19 , Nanofibras , Humanos , Cetrimônio , Nanofibras/química , Pandemias , Polímeros/química , Eletricidade Estática
9.
Biosens Bioelectron ; 190: 113388, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34098362

RESUMO

Co-circulation of coronavirus disease 2019 (COVID-19) and dengue fever has been reported. Accurate and timely multiplex diagnosis is required to prevent future pandemics. Here, we developed an innovative microfluidic chip that enables a snapshot multiplex immunoassay for timely on-site response and offers unprecedented multiplexing capability with an operating procedure similar to that of lateral flow assays. An open microchannel assembly of individually engineered microbeads was developed to construct nine high-density test lines, which can be imaged in a 1 mm2 field-of-view. Thus, simultaneous detection of multiple antibodies would be achievable in a single high-resolution snapshot. Next, we developed a novel pixel intensity-based imaging process to distinguish effective and non-specific fluorescence signals, thereby improving the reliability of this fluorescence-based immunoassay. Finally, the chip specifically identified and classified random combinations of arbovirus (Zika, dengue, and chikungunya viruses) and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies within 30 min. Therefore, we believe that this snapshot multiplex immunoassay chip is a powerful diagnostic tool to control current and future pandemics.


Assuntos
Técnicas Biossensoriais , COVID-19 , Infecção por Zika virus , Zika virus , Humanos , Imunoensaio , Reprodutibilidade dos Testes , SARS-CoV-2
10.
Sci Rep ; 11(1): 16776, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34408220

RESUMO

We developed a reusable surface-amplified nanobiosensor for monitoring airborne viruses with a sub-PFU/mL level detection limit. Here, sandwich structures consisted of magnetic particles functionalized with antibodies, target viruses, and alkaline phosphatases (ALPs) were formed, and they were magnetically concentrated on Ni patterns near an electrochemical sensor transducer. Then, the electrical signals from electrochemical markers generated by ALPs were measured with the sensor transducer, enabling highly-sensitive virus detection. The sandwich structures in the used sensor chip could be removed by applying an external magnetic field, and we could reuse the sensor transducer chip. As a proof of concepts, the repeated detection of airborne influenza virus using a single sensor chip was demonstrated with a detection limit down to a sub-PFU/mL level. Using a single reusable sensor transducer chip, the hemagglutinin (HA) of influenza A (H1N1) virus with different concentrations were measured down to 10 aM level. Importantly, our sensor chip exhibited reliable sensing signals even after more than 18 times of the repeated HA sensing measurements. Furthermore, airborne influenza viruses collected from the air could be measured down to 0.01 PFU/mL level. Interestingly, the detailed quantitative analysis of the measurement results revealed the degradation of HA proteins on the viruses after the air exposure. Considering the ultrasensitivity and reusability of our sensors, it can provide a powerful tool to help preventing epidemics by airborne pathogens in the future.


Assuntos
Técnicas Biossensoriais , Glicoproteínas de Hemaglutininação de Vírus da Influenza/análise , Vírus da Influenza A Subtipo H1N1 , Humanos , Limite de Detecção , Sensibilidade e Especificidade
11.
Environ Sci Technol Lett ; 8(4): 339-344, 2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37566380

RESUMO

During the COVID-19 pandemic, face masks have become limited in stock. Most of sterilization methods are not applicable for eliminating virus from face masks without compromising the filtration efficiency of the masks. In this study, using a human coronavirus (HCoV-229E) as a surrogate for SARS-CoV-2 contamination on KF94 face masks, we show that the virus loses its infectivity with a 4 log reduction when exposed for 10 s to 120 ppm ozone gas produced by a dielectric barrier discharge plasma generator. Scanning electron microscopy, particulate filtration efficiency (PFE), and inhalation resistance tests revealed that there was no detectable structural or functional deterioration observed in the electrocharged filter layer of Korea Filter (KF) 94 masks even after their excessive exposure to ozone. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) showed decreases in amplification efficiency of HCoV-229E RNA recovered from masks exposed to ozone, indicating the damage to the RNA by the ozone treatment. Our results demonstrate that the plasma generator rapidly disinfects contaminated face masks at least five times without compromising filtration efficiency.

12.
Biosens Bioelectron ; 187: 113324, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34020222

RESUMO

Influenza viruses are responsible for several pandemics and seasonal epidemics and pose a major public health threat. Even after a major outbreak, the emergence of drug-resistant influenza viruses can pose disease control problems. Here we report a novel 6E3 monoclonal antibody capable of recognizing and binding to the H275Y neuraminidase (NA) mutation, which has been associated with reduced susceptibility of influenza viruses to NA inhibitors. The 6E3 antibody had a KD of 72.74 µM for wild-type NA and 32.76 pM for H275Y NA, suggesting that it can identify drug-resistant pandemic H1N1 (pH1N1) influenza virus. Molecular modeling studies also suggest the high-affinity binding of this antibody to pH1N1 H275Y NA. This antibody was also subject to dot-blot, enzyme-linked immunosorbent assay, bare-eye detection, and lateral flow assay to demonstrate its specificity to drug-resistant pH1N1. Furthermore, it was immobilized on Au nanoplate and nanoparticles, enabling surface-enhanced Raman scattering (SERS)-based detection of the H275Y mutant pH1N1. Using 6E3 antibody-mediated SERS immunoassay, the drug-resistant influenza virus can be detected at a low concentration of 102 plaque-forming units/mL. We also detected pH1N1 in human nasopharyngeal aspirate samples, suggesting that the 6E3-mediated SERS assay has the potential for diagnostic application. We anticipate that this newly developed antibody and SERS-based immunoassay will contribute to the diagnosis of drug-resistant influenza viruses and improve treatment strategies for influenza patients.


Assuntos
Técnicas Biossensoriais , Vírus da Influenza A Subtipo H1N1 , Influenza Humana , Preparações Farmacêuticas , Antivirais , Farmacorresistência Viral/genética , Humanos , Imunoensaio , Influenza Humana/tratamento farmacológico
13.
Biosens Bioelectron ; 191: 113406, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34167074

RESUMO

On-site severe acute respiratory syndrome coronavirus 2 (SARS CoV-2) serological assays allow for timely in-field decisions to be made regarding patient status, also enabling population-wide screening to assist in controlling the coronavirus disease 2019 (COVID-19) pandemic. Here we propose a rapid microfluidic serological assay with two unique functions of nanointerstice filling and digitized flow control, which enable the fast/robust filling of the sample fluid as well as precise regulation of duration and volume of immune reaction. Developed microfluidic assay showed enhanced limit of detection, and 91.67% sensitivity and 100% specificity (n = 152) for clinical samples of SARS CoV-2 patients. The assay enables daily monitoring of IgM/IgG titers and patterns, which could be crucial parameters for convalescence from COVID-19 and provide important insight into how the immune system responds to SARS CoV-2. The developed on-site microfluidic assay presented the mean time for IgM and IgG seroconversions, indicating that these titers plateaued days after seroconversion. The mean duration from day 0 to PCR negativity was 19.4 days (median 20 d, IQR 16-21 d), with higher IgM/IgG titres being observed when PCR positive turns into negative. Simple monitoring of these titres promotes rapid on-site detection and comprehensive understanding of the immune response of COVID-19 patients.


Assuntos
Técnicas Biossensoriais , COVID-19 , Anticorpos Antivirais , Humanos , Imunoensaio , Imunoglobulina G , Imunoglobulina M , SARS-CoV-2 , Sensibilidade e Especificidade , Testes Sorológicos
14.
ACS Appl Mater Interfaces ; 12(26): 29103-29109, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32543174

RESUMO

To prevent the transmission of pathogenic microorganisms such as the influenza virus, efficient pathogen-capturing materials are required. Here, we report a new pathogen-capturing and recovery material using levan polysaccharide. We fabricated hydrogels by blending levan and poly(vinyl alcohol) (PVA) and by using glutaraldehyde as a cross-linking agent. Fabricated levan-PVA hydrogels have a high water solubility and water adsorption ability. SEM observations showed that levan-PVA hydrogels have a 3D porous structure. We confirmed by RT-PCR analysis that the influenza virus capture efficiency of levan-PVA hydrogels is higher than that of commercial cotton swabs. Moreover, we confirmed that levan-PVA hydrogels on gauze as a filter material effectively captured bioaerosol samples. Therefore, levan-PVA hydrogels are expected to serve as simple and efficient pathogen capture and recovery materials.


Assuntos
Frutanos/química , Hidrogéis/química , Álcool de Polivinil/química , Glutaral/química , Hidrogéis/farmacologia , Orthomyxoviridae/efeitos dos fármacos , Reação em Cadeia da Polimerase Via Transcriptase Reversa
15.
Micromachines (Basel) ; 11(2)2020 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-32079062

RESUMO

Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (µFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the µFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.

16.
Biosens Bioelectron ; 131: 280-286, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30849728

RESUMO

In the study, we describe an oscillatory flow-assisted efficient target enrichment method by using a particle-based microarray device. Periodic oscillating flow effectively increased the mixing and binding performance between the target molecules in the sample solution and surface functionalized microparticles. Particles were trapped, secured, and released with an elastic microvalve structure operated via differences in the flow conditions. Single particle (20-µm diameter) trapping efficiency exceeded 95%. Secured particles can freely move inside each array element based on oscillating sample flow. Furthermore, the particles can be released from the array and collected at the outlet of the device, and this provides an opportunity for further off-chip analysis. As a proof-of-concept, we used the interaction between streptavidin-coated microparticles and fluorescence labeled biotin solution and demonstrated that target enrichment and detection based on oscillatory flow were significantly more efficient than that based on unidirectional or static flow. The applicability of the method was further examined by conducting an on-chip immunoassay to detect the presence of anti-Zika nonstructural protein 1 (NS1) monoclonal antibody. The limit of detection (LOD) was as low as 1 ng/mL with an assay time of only 10 min and less than 10 µL of sample consumption.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Técnicas Biossensoriais , Proteínas não Estruturais Virais/isolamento & purificação , Infecção por Zika virus/diagnóstico , Anticorpos Monoclonais/imunologia , Humanos , Imunoensaio , Limite de Detecção , Técnicas Analíticas Microfluídicas , Tamanho da Partícula , Soluções/química , Propriedades de Superfície , Proteínas não Estruturais Virais/imunologia , Infecção por Zika virus/virologia
17.
ACS Omega ; 4(11): 14560-14568, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31528810

RESUMO

Several microRNAs (miRNAs) have been reported to be closely related to influenza A virus infection, replication, and immune response. Therefore, the development of the infectious-disease detection system using miRNAs as biomarkers is actively underway. Herein, we identified two miRNAs (miR-181c-5p and miR-1254) as biomarkers for detection of pandemic influenza A H1N1 virus infection and proposed the catalytic hairpin assembly-based in vitro diagnostic (CIVD) system for a highly sensitive diagnosis; this system is composed of two sets of cascade hairpin probes enabling to detect miR-181c-5p and miR-1254. We demonstrated that CIVD kits could not only detect subnanomolar levels of target miRNAs but also distinguish even single-base mismatches. Moreover, this CIVD kit has shown excellent detection performance in real intracellular RNA samples and confirmed results similar to those of conventional methods (microarray and quantitative real-time polymerase chain reaction).

19.
Antiviral Res ; 70(3): 93-104, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16546268

RESUMO

The influence of the thymidine (Thd) kinase (TK) of herpes simplex virus type 1 (HSV-1) on the intracellular uptake and anabolism of nucleosides has been investigated. To compare the differences between the TK-positive (TK(+)) and TK-deficient strains, acyclovir (ACV)-resistant strains were cloned from a cell culture and classified into 2 groups, viz. the TK-partial (TK(p)) and TK-negative (TK(-)). The cellular uptake of thymidine was highly dependent on the viral TK (vTK) activity. The TK(+) strain showed the highest level of intracellular thymidine uptake, the TK(p) strain a moderate level, which varied from strain to strain, and the TK(-) and mock strains showed little uptake. The inhibition of viral replication by ACV, ganciclovir (GCV) and penciclovir (PCV) did not decrease the Thd uptake at all. On the contrary, a notable increase found to be induced by ACV. The influence of the vTK on the uptake of GCV or PCV was much greater than that of ACV. The metabolism was generally less dependent on the vTK activity than the influx. The influx and phosphorylation rates of GCV and PCV were dependent on the substrate specificity of the vTK.


Assuntos
Antivirais/metabolismo , DNA Viral/metabolismo , DNA/metabolismo , Herpesvirus Humano 1/enzimologia , Timidina Quinase/metabolismo , Timidina/metabolismo , Aciclovir/análogos & derivados , Aciclovir/metabolismo , Aciclovir/farmacologia , Animais , Antivirais/farmacologia , Linhagem Celular Tumoral , Chlorocebus aethiops , Farmacorresistência Viral , Ganciclovir/metabolismo , Ganciclovir/farmacologia , Guanina , Herpesvirus Humano 1/patogenicidade , Humanos , Mutação , Especificidade por Substrato , Timidina Quinase/genética , Células Vero
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa