Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Medicina (Kaunas) ; 60(5)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38792912

RESUMO

Background and Objectives: No comparative study has evaluated the inter-method agreement and reliability between Heuron AD and other clinically available brain volumetric software packages. Hence, we aimed to investigate the inter-method agreement and reliability of three clinically available brain volumetric software packages: FreeSurfer (FS), NeuroQuant® (NQ), and Heuron AD (HAD). Materials and Methods: In this study, we retrospectively included 78 patients who underwent conventional three-dimensional (3D) T1-weighed imaging (T1WI) to evaluate their memory impairment, including 21 with normal objective cognitive function, 24 with mild cognitive impairment, and 33 with Alzheimer's disease (AD). All 3D T1WI scans were analyzed using three different volumetric software packages. Repeated-measures analysis of variance, intraclass correlation coefficient, effect size measurements, and Bland-Altman analysis were used to evaluate the inter-method agreement and reliability. Results: The measured volumes demonstrated substantial to almost perfect agreement for most brain regions bilaterally, except for the bilateral globi pallidi. However, the volumes measured using the three software packages showed significant mean differences for most brain regions, with consistent systematic biases and wide limits of agreement in the Bland-Altman analyses. The pallidum showed the largest effect size in the comparisons between NQ and FS (5.20-6.93) and between NQ and HAD (2.01-6.17), while the cortical gray matter showed the largest effect size in the comparisons between FS and HAD (0.79-1.91). These differences and variations between the software packages were also observed in the subset analyses of 45 patients without AD and 33 patients with AD. Conclusions: Despite their favorable reliability, the software-based brain volume measurements showed significant differences and systematic biases in most regions. Thus, these volumetric measurements should be interpreted based on the type of volumetric software used, particularly for smaller structures. Moreover, users should consider the replaceability-related limitations when using these packages in real-world practice.


Assuntos
Encéfalo , Software , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso de 80 Anos ou mais
2.
Medicina (Kaunas) ; 60(2)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38399556

RESUMO

Background and Objectives: Traumatic vascular injuries of the head and neck pose significant treatment challenges due to the complex anatomy, diverse clinical presentation, and mostly emergent nature. Endovascular treatment increasingly complements traditional surgical approaches. This study aimed to report our 10-year experience in treating traumatic vascular injuries of the head and neck with endovascular therapy and to determine the effectiveness of endovascular treatment. Materials and Methods: A retrospective analysis of 21 patients treated for head and neck vascular injuries between May 2011 and April 2021 was performed. Patients' medical histories, clinical presentations, imaging findings, treatment materials, and clinical outcomes were reviewed. Treatments included stenting, coil embolization, and other endovascular techniques focused on hemostasis and preservation of the parent vessel. Results: The most common injuries involved the internal maxillary artery branches (n = 11), followed by the common or internal carotid artery (n = 6), vertebral artery (n = 3), and others. Endovascular treatment achieved successful hemostasis in all but one case. In five of six carotid artery injuries and two of three vertebral artery injuries, we achieved successful hemostasis while preserving the parent vessel using covered and bare stents, respectively. Conclusions: Endovascular therapy might be a useful treatment modality for traumatic vascular injuries in the head and neck region, offering efficacy, safety, and a minimally invasive approach.


Assuntos
Lesões das Artérias Carótidas , Procedimentos Endovasculares , Lesões do Sistema Vascular , Humanos , Lesões do Sistema Vascular/etiologia , Estudos Retrospectivos , Lesões das Artérias Carótidas/cirurgia , Lesões das Artérias Carótidas/etiologia , Pescoço , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento
3.
J Clin Ultrasound ; 51(9): 1589-1595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37883105

RESUMO

PURPOSE: The purpose of this study was to assess the prevalence and clinical implications of false-positive supraclavicular lymph node (LN) detected on chest computed tomography (CT), using subsequent neck ultrasonography (US) and US-guided tissue sampling. METHODS: Among 172 patients with suspected supraclavicular LNs identified on CT, 87 underwent neck US or US-guided tissue sampling. Receiver operating characteristic curve and logistic regression analyses were performed to determine the diagnostic performance of US and independent predictors of false-positive LNs. RESULTS: Among 87 patients, 49 (56.3%) were pathologically confirmed as metastases, 26 (29.9%) were negative for malignancy, and 12 (13.8%) had pseudolesions or schwannomas. The diagnostic indices were as follows: sensitivity, 91.8%; specificity, 92.3%; PPV, 95.7%; NPV, 85.7%; and accuracy, 92.0% (AUC = 0.921; 95% CI: 0.832-0.970, p < 0.001). The false-positive group had a higher mean age than the true-positive group (mean age, 69.8 ± 9.2 vs. 63.9 ± 9.8, p = 0.003). Logistic regression analyses revealed that age ≥ 65 years was the only independent predictor of false-positive LNs (OR = 4.391; 95% CI: 1.037-18.582; p = 0.044). CONCLUSION: Subsequent US can be helpful for evaluating suspicious supraclavicular LNs detected on CT to establish appropriate management, especially in older patients.


Assuntos
Linfonodos , Tomografia Computadorizada por Raios X , Humanos , Idoso , Pessoa de Meia-Idade , Metástase Linfática/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Ultrassonografia/métodos
4.
Medicina (Kaunas) ; 59(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37374376

RESUMO

Background and Objectives: Vascular abnormalities within the anatomical coverage are frequently encountered in imaging studies. The aortic arch is often overlooked as an anatomical blind spot, especially in neck magnetic resonance (MR) angiography. This study investigated the prevalence of incidental aortic arch abnormalities. We also estimated the potential clinical significance of aortic arch abnormalities as blind spots detected on contrast-enhanced neck MR angiography. Materials and Methods: Between February 2016 and March 2023, 348 patients were identified based on contrast-enhanced neck MR angiography reports. The clinical and radiological characteristics of the patients and the presence of additional imaging studies were assessed. The aortic arch abnormalities and coexisting non-aortic arterial abnormalities were classified into two categories according to their clinical significance. We performed the χ2 test and Fisher's exact test for group comparisons. Results: Of the 348 study patients, only 29 (8.3%) had clinically significant incidental aortic arch abnormalities. Among these 348 patients, 250 (71.8%) and 136 (39%) had intracranial and extracranial abnormalities, respectively; the clinically significant intracranial abnormalities in the two groups were 130 lesions (52.0%) and 38 lesions (27.9%), respectively. In addition, there was a significantly higher tendency of clinically significant aortic arch abnormalities (13/29, 44.8%) in the patients who had clinically significant coexisting non-aortic arterial abnormalities than in the other group (87/319, 27.3%) (p = 0.044). The patient groups with clinically significant intracranial or extracranial arterial abnormalities had higher rates of clinically significant aortic abnormalities (31.0% and 17.2%), but there was no statistical significance (p = 0.136). Conclusions: The incidence of clinically significant aortic arch abnormalities was 8.3% on neck MR angiography, with a significant association between aortic and coexisting non-aortic arterial abnormalities. The findings of this study could improve the understanding of incidental aortic arch lesions on neck MR angiography, which is of crucial clinical importance for radiologists to achieve accurate diagnoses and management.


Assuntos
Cardiopatias Congênitas , Doenças Vasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Prevalência , Angiografia por Ressonância Magnética/métodos , Pescoço/diagnóstico por imagem , Cardiopatias Congênitas/patologia
5.
AJR Am J Roentgenol ; 218(6): 1062-1073, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34985311

RESUMO

BACKGROUND. Isotropic 3D T1-weighted imaging has long acquisition times, potentially leading to motion artifact and altered brain volume measurements. Acquisition times may be greatly shortened using an isotropic ultrafast 3D echo-planar imaging (EPI) T1-weighted sequence. OBJECTIVE. The purpose of this article was to compare automated brain volume measurements between conventional 3D T1-weighted imaging and ultrafast 3D EPI T1-weighted imaging. METHODS. This retrospective study included 36 patients (25 women, 11 men; mean age, 68.4 years) with memory impairment who underwent 3-T brain MRI. Examinations included both conventional 3D T1-weighted imaging using inversion recovery gradient-recalled echo sequence (section thickness, 1.0 mm; acquisition time, 3 minutes 4 seconds) and, in patients exhibiting motion, an isotropic ultrafast 3D EPI T1-weighted sequence (section thickness, 1.2 mm; acquisition time, 30 seconds). The 36-patient sample excluded five patients in whom severe motion artifact rendered the conventional sequence of insufficient quality for volume measurements. Automated brain volumetry was performed using NeuroQuant (version 3.0, CorTechs Laboratories) and FreeSurfer (version 7.1.1, Harvard University) software. Volume measurements were compared between sequences for nine regions in each hemisphere. RESULTS. Volumes showed substantial to almost perfect agreement between the two sequences for most regions bilaterally. However, most regions showed significant mean differences between sequences, and Bland-Altman analyses showed consistent systematic biases and wide limits of agreement (LOA). For example, for the left hemisphere using NeuroQuant, volume was significantly greater for the ultrafast sequence in four regions and significantly greater for the conventional sequence in three regions, whereas standardized effect size between sequences was moderate for four regions and large for one region. Using NeuroQuant, mean bias (ultrafast minus conventional) and 95% LOA were greatest in cortical gray matter bilaterally (-50.61 cm3 [-56.27 cm3, -44.94 cm3] for the left hemisphere; -50.02 cm3 [-54.88 cm3, -45.16 cm3] for the right hemisphere). The variation between the two sequences was observed in subset analyses of 16 patients with and 20 patients without Alzheimer disease. CONCLUSION. Brain volume measurements show significant differences and systematic biases between the conventional and ultrafast sequences. CLINICAL IMPACT. In patients in whom severe motion artifact precludes use of the conventional sequence, the ultrafast sequence may be useful to enable brain volume-try. However, the current conventional 3D T1-weighted sequence remains preferred in patients who can tolerate the standard examination.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Idoso , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
6.
AJR Am J Roentgenol ; 216(5): 1329-1334, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33655773

RESUMO

OBJECTIVE. This retrospective study aimed to investigate the capability of the already-proposed thyroid imaging reporting and data system for detecting diffuse thyroid disease (DTD-TIRADS) on ultrasound (US) by assessing interobserver agreement and diagnostic performance. MATERIALS AND METHODS. A total of 180 patients who underwent thyroid US before thyroid surgery were included. Three radiologists blinded to the pathologic and serologic data independently categorized the US features according to a four-category DTD-TIRADS classification system. On the basis of the pathologic results of thyroid parenchyma, diagnostic performance values were calculated using ROC curve analyses. Interobserver agreements of each US feature and DTD-TIRADS category among the three radiologists were also assessed. RESULTS. Of the 180 patients, 143 (79.4%) had normal thyroid parenchyma and 37 (20.6%) had diffuse thyroid disease (DTD). The areas under the ROC curve for DTD were not significantly different among the three radiologists: 0.876 (95% CI, 0.819-0.920) for radiologist 1, 0.883 (95% CI, 0.827-0.926) for radiologist 2, and 0.861 (95% CI, 0.801-0.908) for radiologist 3 (p > .05). The cutoff for the diagnosis of DTD was category III DTD-TIRADS. The sensitivity, specificity, and accuracy of DTD-TIRADS for detecting DTD were 86.5%, 81.1%, and 82.2% for radiologist 1; 86.5%, 83.2%, and 83.9% for radiologist 2; and 83.8%, 82.5%, and 82.8% for radiologist 3, respectively. Interobserver agreement of DTD-TIRADS categorization was almost perfect (κ = 0.81). CONCLUSION. DTD-TIRADS has high diagnostic performance and almost-perfect interobserver agreement. Thus, DTD-TIRADS can be considered to be an effective classification system for diagnosing DTD.


Assuntos
Sistemas de Informação em Radiologia/normas , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Glândula Tireoide/diagnóstico por imagem , Adulto Jovem
7.
J Clin Ultrasound ; 49(6): 610-613, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33782976

RESUMO

Silicone-induced lymphadenopathy is a rare complication associated with silicone breast implants. It is usually asymptomatic and found incidentally during imaging. We report a case of silicone lymphadenopathy in a patient who had undergone a mastectomy and breast reconstruction for breast cancer. During follow-up, a positron emission tomography-computed tomography examination revealed lymph nodes that were suspicious for cancer recurrence. However, sonography was able to correctly diagnose silicone-induced lymphadenopathy and exclude cancer metastasis.


Assuntos
Neoplasias da Mama/diagnóstico , Linfadenopatia/induzido quimicamente , Linfadenopatia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Silicones/efeitos adversos , Implantes de Mama/efeitos adversos , Diagnóstico Diferencial , Humanos , Linfadenopatia/patologia , Pessoa de Meia-Idade , Recidiva , Ultrassonografia
8.
Medicina (Kaunas) ; 57(8)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34441042

RESUMO

Background and objective: This study was conducted to assess the prevalence and clinical implications of parotid lesions detected incidentally during brain magnetic resonance imaging (MRI) examination. Materials and Methods: Between February 2016 and February 2021, we identified 86 lesions in the brain MRI reports of 84 patients that contained the words "parotid gland" or "PG". Of these, we finally included 49 lesions involving 45 patients following histopathological confirmation. Results: Based on the laboratory, radiological or histopathological findings, the prevalence of incidental parotid lesions was low (1.2%). Among the 45 study patients, 41 (91.1%) had unilateral lesions, and the majority of the lesions were located in the superficial lobe (40/49, 81.6%). The mean size of the parotid lesions was 1.3 cm ± 0.4 cm (range, 0.5 cm-2.8 cm). Of these, 46 parotid lesions (93.9%) were benign, whereas the remaining three lesions were malignant (6.1%). Conclusions: Despite the low prevalence and incidence of malignancy associated with incidental parotid lesions detected on brain MRI, the clinical implications are potentially significant. Therefore, clinical awareness and appropriate imaging work-up of these lesions are important for accurate diagnosis and timely management.


Assuntos
Imageamento por Ressonância Magnética , Glândula Parótida , Encéfalo/diagnóstico por imagem , Humanos , Glândula Parótida/diagnóstico por imagem , Prevalência , Estudos Retrospectivos
9.
Eur Radiol ; 30(5): 2782-2790, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32025829

RESUMO

OBJECTIVES: To evaluate the predictive value of virtual monoenergetic images (VMIs) by assessing tumor conspicuity on dual-layer spectral detector CT (SDCT) and correlate tumor conspicuity on VMI with prognostic biomarkers in patients with breast cancer. METHODS: Sixty-four patients underwent arterial phase and 90-s delayed phase dual-layer SDCT. A retrospective tumor conspicuity analysis of 14 benign tumors and 65 breast cancers was performed using conventional images (CIs) and VMI at 40 keV (VMI40) on arterial and delayed phase scans (CIART, VMI40ART, CIDE, VMI40DE). Mean Hounsfield units (HU) of tumors were measured on VMI40ART and VMI40DE. A receiver operating characteristic (ROC) curve analysis was performed to compare diagnostic accuracy between image sets. Estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2), and Ki67 levels were evaluated using histopathology. Correlations between VMI analyses and histological characteristics of cancers were analyzed. RESULTS: Cancers on VMI40 had a significantly higher conspicuity score and mean HU than benign tumors (p < 0.001). VMI40DE showed the highest conspicuity for cancers (mean, 3.79) and the greatest area under the ROC curve (0.817; 95% confidence interval 0.745-0.889). VMI40DE yielded significantly higher mean HU for cancers than VMI40ART (p < 0.001). The conspicuity score and mean HU on VMI40ART were significantly higher in cancers with ER negativity, PR negativity, and Ki67 positivity (p < 0.05). CONCLUSIONS: VMI40DE may be useful in the diagnosis of breast cancers due to higher tumor conspicuity and better enhancement than VMI40ART. VMI40ART may be beneficial for the prediction of poor breast cancer prognoses. KEY POINTS: • VMI40 improved conspicuity of breast cancer than CI. • VMI40DEyielded higher diagnostic performance of breast cancer than VMI40ART. • VMI40ARThas an additional benefit in terms of prognosis prediction in patients with breast cancers.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/diagnóstico , Meios de Contraste/farmacologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/metabolismo , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos
10.
Eur Radiol ; 30(1): 206-212, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31399751

RESUMO

OBJECTIVES: To evaluate the intraobserver and interobserver reliability of gallbladder polyp measurements using transabdominal US and the factors that affect reliability. METHODS: From November 2017 to February 2018, two radiologists measured the maximum diameter of 91 gallbladder polyps using transabdominal US. Intraobserver and interobserver agreement were determined using 95% Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs). The effects of image settings, polyp location, and polyp size were evaluated by comparing ICCs using z tests. RESULTS: The intraobserver agreement rates were 0.960 (95% confidence interval [CI], 0.939-0.973) for observer 1 and 0.962 (95% CI, 0.943-0.975) for observer 2. The ICCs between the two observers were 0.963 (95% CI, 0.926-0.979) for the first measurement and 0.973 (95% CI, 0.950-0.984) for the second measurement. The 95% limits of agreement on repeated measurements were 22.3-25.2% of the mean, and those between the two observers were 25.5-34.2% of the mean. ICCs for large polyps (≥ 5 mm) were significantly higher than those for small polyps (< 5 mm). There were no significant differences in the ICCs between image settings and polyp location. CONCLUSIONS: Polyp size measurements using transabdominal US are highly repeatable and reproducible. Polyp size significantly affects the reliability of measurement. Diameter changes of approximately less than 25% may fall within the measurement error; this should be considered while interpreting the change in size during follow-up US, especially for small polyps. KEY POINTS: • Gallbladder polyp size measurement using transabdominal US is highly repeatable and reproducible. • Diameter changes of approximately less than 25% should be interpreted carefully, especially in small polyps.


Assuntos
Doenças da Vesícula Biliar/diagnóstico por imagem , Pólipos/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ultrassonografia , Adulto Jovem
11.
AJR Am J Roentgenol ; 215(1): 198-205, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32255685

RESUMO

OBJECTIVE. The long scan time of brain MRI is a major drawback that limits its clinical use for evaluating pediatric patients who are inherently prone to motion and frequently require sedatives. This study investigated the clinical feasibility of a 1-minute ultrafast brain MRI protocol in pediatric patients by assessing its image quality in comparison with that of routine brain MRI. MATERIALS AND METHODS. Twenty-three patients were enrolled who underwent 1-minute ultrafast MRI and routine brain MRI protocols including five essential sequences (T1-weighted imaging, T2-weighted imaging, DWI, FLAIR, and T2*-weighted imaging). Total scan time for the same image contrast levels was 1 minute 11 seconds for ultrafast MRI versus 9 minutes 51 seconds for routine brain MRI. Two readers independently reviewed all images from the two MRI protocols and graded the image quality on a 4-point Likert scale. The Wilcoxon signed rank test was used to compare the readers' ratings; interobserver agreement between the readers was also assessed. RESULTS. Although the mean scores of overall image quality and anatomic delineation in ultrafast brain MR images were significantly lower than those in routine brain MR images, ultrafast brain MRI showed sufficient overall image quality and anatomic delineation with more than 2 points on the 4-point scale. CONCLUSION. The 1-minute ultrafast brain MRI protocol showed at least sufficient image quality compared with routine brain MRI. Therefore, 1-minute ultrafast brain MRI can be a viable first-line neuroimaging study for pediatric patients because of its shorter scan time, absence of radiation hazard, and reduced sedation requirements.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Pediatria/métodos , Adolescente , Artefatos , Criança , Pré-Escolar , Sedação Consciente , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Tempo
12.
J Neuroradiol ; 47(2): 151-160, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30951770

RESUMO

BACKGROUND AND PURPOSE: We investigated the clinical feasibility of synthetic MRI with a 4-min single scan using a 48-channel head coil as a routine neuroimaging protocol in daily practice by assessing its diagnostic image quality. METHODS: We retrospectively reviewed the imaging data of 89 patients who underwent routine brain MRI using synthetic MRI acquisition between February 2017 and April 2017. Image quality assessments were performed by two independent readers on synthetic T1 fluid-attenuated inversion recovery (FLAIR), T2-weighted, T2 FLAIR, and phase-sensitive inversion recovery sequences acquired using multiple-dynamic multiple-echo imaging. Interobserver reliability between the two readers was assessed using kappa (κ) statistics. RESULTS: On a 4-point assessment scale, the overall image quality and anatomical delineation provided by synthetic brain MRI were found to be good with scores of more than 3 points for all sequences except for the T2 FLAIR sequence. The synthetic T2 FLAIR sequence provided sufficient image quality but showed more pronounced artifacts, especially the CSF pulsation artifact and linear hyperintensity along the brain surface. Interobserver agreement for evaluating image quality of all synthetic sequences was good to excellent (κ, 0.61-0.99; P < 0.001). CONCLUSION: Synthetic MRI can be acceptable as a routine clinical neuroimaging protocol with a short scan time. It can be helpful to design customized and flexible neuroimaging protocols for each institution.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Aumento da Imagem/métodos , Lactente , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
13.
Medicina (Kaunas) ; 57(1)2020 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-33379265

RESUMO

Chronic intradiploic organizing hematoma of the skull is a rare lesion that usually presents as a progressively growing mass after head trauma, thus making it difficult to diagnose. To date, only nine cases that have been histopathologically confirmed as organizing hematoma of the skull have been reported in the literature. Herein, we describe a case of a chronic organizing hematoma involving the right parietal bone, presenting as a slowly growing mass in a 54-year-old man. The lesion was also visualized on magnetic resonance imaging (MRI) with a zero echo time sequence. In this case report, we emphasize that chronic intradiploic organizing hematoma should be considered in the differential diagnosis of a palpable scalp mass. We also highlight the importance of meticulous radiological review in the context of appropriate clinical suspicion and the usefulness of the zero TE sequence in evaluating calvarial lesions.


Assuntos
Neoplasias Cranianas , Crânio , Diagnóstico Diferencial , Hematoma/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiografia , Crânio/diagnóstico por imagem , Neoplasias Cranianas/diagnóstico por imagem
14.
J Magn Reson Imaging ; 50(5): 1413-1423, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30884007

RESUMO

BACKGROUND: FLAIR (fluid attenuated inversion recovery) imaging via synthetic MRI methods leads to artifacts in the brain, which can cause diagnostic limitations. The main sources of the artifacts are attributed to the partial volume effect and flow, which are difficult to correct by analytical modeling. In this study, a deep learning (DL)-based synthetic FLAIR method was developed, which does not require analytical modeling of the signal. PURPOSE: To correct artifacts in synthetic FLAIR using a DL method. STUDY TYPE: Retrospective. SUBJECTS: A total of 80 subjects with clinical indications (60.6 ± 16.7 years, 38 males, 42 females) were divided into three groups: a training set (56 subjects, 62.1 ± 14.8 years, 25 males, 31 females), a validation set (1 subject, 62 years, male), and the testing set (23 subjects, 57.3 ± 20.4 years, 13 males, 10 females). FIELD STRENGTH/SEQUENCE: 3 T MRI using a multiple-dynamic multiple-echo acquisition (MDME) sequence for synthetic MRI and a conventional FLAIR sequence. ASSESSMENT: Normalized root mean square (NRMSE) and structural similarity (SSIM) were computed for uncorrected synthetic FLAIR and DL-corrected FLAIR. In addition, three neuroradiologists scored the three FLAIR datasets blindly, evaluating image quality and artifacts for sulci/periventricular and intraventricular/cistern space regions. STATISTICAL TESTS: Pairwise Student's t-tests and a Wilcoxon test were performed. RESULTS: For quantitative assessment, NRMSE improved from 4.2% to 2.9% (P < 0.0001) and SSIM improved from 0.85 to 0.93 (P < 0.0001). Additionally, NRMSE values significantly improved from 1.58% to 1.26% (P < 0.001), 3.1% to 1.5% (P < 0.0001), and 2.7% to 1.4% (P < 0.0001) in white matter, gray matter, and cerebral spinal fluid (CSF) regions, respectively, when using DL-corrected FLAIR. For qualitative assessment, DL correction achieved improved overall quality, fewer artifacts in sulci and periventricular regions, and in intraventricular and cistern space regions. DATA CONCLUSION: The DL approach provides a promising method to correct artifacts in synthetic FLAIR. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1413-1423.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Aprendizado Profundo , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Endocr Pract ; 25(10): 1035-1040, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31241363

RESUMO

Objective: This study aimed to evaluate factors influencing the successful maintenance of postoperative euthyroidism in patients who did not undergo immediate thyroid hormone replacement after lobectomy for papillary thyroid microcarcinoma (PTMC). Methods: From September 2015 to June 2017, 186 patients underwent lobectomy for PTMC in our hospital. Patients taking medications for hypothyroidism and hyperthyroidism before and after lobectomy were excluded. Multiple parameters, including sex, age, pre-operative free thyroxine (T4), thyroid-stimulating hormone (TSH), thyroglobulin (TG), and thyroid autoantibody levels, body mass index (BMI), postoperative histopathology of the thyroid gland, remnant thyroid gland volume, and session number of levothyroxine discontinuation were retrospectively evaluated. These factors were compared between groups based on the maintenance of postoperative euthyroidism. Results: In 88 of the 175 patients (50.3%), postoperative euthyroidism was successfully maintained without thyroid hormone replacement during the first year after lobectomy. There were significant differences in sex (P = .003), pre-operative TSH levels (P = .002), and histopathology of the thyroid gland (P = .035) between the groups showing maintenance success and failure. The group showing successful maintenance had a higher percentage of male patients, lower levels of pre-operative TSH, and normal parenchymal histology of the thyroid gland. However, there were no significant between-group differences in age, pre-operative free T4, TG, and thyroid autoantibody levels, BMI, remnant thyroid gland volume, and session number of levothyroxine discontinuation. Conclusion: Patient sex, pre-operative TSH levels, and histopathology of the thyroid gland may influence the maintenance of postoperative euthyroidism after lobectomy. Abbreviations: BMI = body mass index; PTMC = papillary thyroid microcarcinoma; RR = reference range; T4 = thyroxine; TFT = thyroid function test; TG = thyroglobulin; TSH = thyroid-stimulating hormone.


Assuntos
Carcinoma Papilar , Neoplasias da Glândula Tireoide , Humanos , Masculino , Estudos Retrospectivos , Tireoidectomia , Tireotropina , Tiroxina
16.
Med Sci Monit ; 25: 9538-9546, 2019 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-31837133

RESUMO

BACKGROUND This study aimed to evaluate the prevalence of thyroglossal duct cysts (TGDCs) on ultrasonography (US) and US features of TGDCs in adults, and to assess whether the prevalence or size of TGDCs increases after radioactive iodine ablation (RIA). MATERIAL AND METHODS Between July and December 2018, 2820 patients underwent thyroid or neck US examination, performed by 2 radiologists, at our center. On the basis of real-time US, the presence or absence of TGDCs was prospectively investigated by 2 radiologists. Among the 2820 patients, 54 patients who were <19 years of age or had a radiation therapy history to the neck were excluded. Eventually, 2766 patients were included. RESULTS Of the 2766 patients, 160 (5.8%) showed a TGDC on US. The mean size of TGDCs in RIA history (+) (n=36) and RIA history (-) (n=124) groups was 0.92±0.41 cm and 0.86±0.45 cm, respectively. There was no significant difference in size of TGDCs between RIA history (+) and RIA history (-) groups (p=0.684). Between the TGDC (+) and TGDC (-) groups, there was no significant difference in patient age, gender, reason for thyroid/neck US, type of thyroid surgery, and session number and application/no application of RIA (p>0.05). The prevalence rate of TGDCs in radiologist A and B was 4.9% (70/1427) and 6.7% (90/1339), respectively. TGDCs were more common in the suprahyoid neck, and the common shapes of TGDCs were flat-to-ovoid and round. CONCLUSIONS RIA may not be associated with the prevalence or enlargement of TGDCs.


Assuntos
Cisto Tireoglosso/diagnóstico por imagem , Cisto Tireoglosso/radioterapia , Técnicas de Ablação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Papilar , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Iodo , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Glândula Tireoide , Neoplasias da Glândula Tireoide , Tomografia Computadorizada por Raios X , Ultrassonografia/métodos
17.
Med Sci Monit ; 25: 6943-6949, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31522188

RESUMO

BACKGROUND This study aimed to assess the utility and characteristics of preoperative ultrasonography (US) in patients transferred to referral hospitals from local clinics with a diagnosis of malignancy on US-guided fine-needle aspiration cytology of thyroid nodules. MATERIAL AND METHODS From January 2018 to June 2018, 109 transferred patients underwent preoperative US in our hospital for suspected thyroid malignancy on cytological analysis after US-guided fine-needle aspiration of thyroid nodules in local clinics. Preoperative US was performed by a single radiologist in all patients. Among them, 6 were excluded from the study because of refusal of thyroid surgery. Preoperative US and histopathological results were compared in all patients. RESULTS After thyroid surgery, pathological examination revealed papillary thyroid carcinoma (PTC) (n=98), follicular adenoma (n=1), and nodular hyperplasia (n=4). Of the 103 patients, 91 exhibited suspicious US findings on the preoperative US, whereas 12 did not. In the 91 patients with suspicious US findings, PTC (n=90) and follicular adenoma (n=1) were confirmed after thyroid surgery. In the 12 patients with no suspicious US findings, PTC (n=8) and nodular hyperplasia (n=4) were confirmed after thyroid surgery. On repeat analysis of the cytological slides of the 4 nodular hyperplasia cases from the local clinics, Bethesda category II (n=1) and III (n=3) were determined. CONCLUSIONS In the transferred patients with a malignant cytology, preoperative US might be helpful to detect false-positive cytology cases.


Assuntos
Cuidados Pré-Operatórios , Utilização de Procedimentos e Técnicas , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia , Adolescente , Adulto , Idoso , Biópsia por Agulha Fina , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/patologia , Carcinoma Papilar/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transferência de Pacientes , Estudos Retrospectivos , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/cirurgia , Adulto Jovem
18.
Medicina (Kaunas) ; 56(1)2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31906183

RESUMO

Background and Objectives: To investigate the diagnostic performance of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and subsequent ultrasonography (US) for determining cervical nodal metastasis in oncology patients. Materials and Methods: Fifty-nine cervical lymph nodes (LNs) initially detected by PET/CT with subsequent neck US were included in this retrospective study. All LNs were subjected to US-guided fine-needle aspiration or core needle biopsy. The maximum standardized uptake value (SUVmax) and sonographic features were assessed. Results: Forty-three of 59 cervical LNs detected by PET/CT were malignant. PET/CT alone showed a highest diagnostic value for metastatic LNs with 81.4% sensitivity, 68.8% specificity, and 78% accuracy when SUVmax ≥5.8 was applied as an optimal cut-off value. Combined PET/CT and subsequent US diagnoses for determining nodal metastasis showed the following diagnostic performance: 81.4% sensitivity, 87.5% specificity, and 83.1% accuracy. There was a significant difference in the diagnostic performance between the two diagnostic imaging approaches (p = 0.006). Conclusions: Combined diagnosis using subsequent US showed a significantly higher diagnostic performance for determining nodal metastasis in the neck. Therefore, we believe that our proposed diagnostic strategy using subsequent US can be helpful in evaluating cervical LNs on PET/CT. Moreover, our results clarify the need for US-guided tissue sampling in oncology patients.


Assuntos
Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Linfonodos/fisiopatologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Pescoço/fisiopatologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Ultrassonografia/métodos
19.
AJR Am J Roentgenol ; 211(3): 649-654, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29995502

RESUMO

OBJECTIVE: The purpose of this multicenter study was to assess the diagnostic accuracy of real-time sonography (US) for differentiating diffuse thyroid disease (DTD) from normal thyroid parenchyma among radiologists blinded to patients' clinical, serologic, and imaging history and to determine the differences in diagnostic accuracy among radiologists from different institutions. MATERIALS AND METHODS: From January to March 2017, 214 patients underwent preoperative thyroid US and subsequent thyroid surgery at four participating institutions. Real-time US was performed at each institution by an attending radiologist, who classified US diagnoses into one of the following four categories based on US findings: no DTD, indeterminate, suspicious for DTD, and DTD. The outcomes of US diagnoses were compared with histopathologic results to determine the diagnostic accuracy of real-time US at each institution. RESULTS: Histopathologic results included normal thyroid parenchyma (n = 143), Hashimoto thyroiditis (n = 29), non-Hashimoto lymphocytic thyroiditis (n = 37), and diffuse hyperplasia (n = 5). Normal thyroid parenchyma and DTD exhibited statistically significant differences in echogenicity, echotexture, size, glandular margin, vascularity of thyroid, and US classification. There was positive correlation between US classification and histopathologic results at all institutions for detecting DTD. The highest diagnostic indexes were obtained when the cutoff criterion was suspicious for DTD. There was favorable diagnostic accuracy, with statistically significant differences, at all institutions for the diagnosis of DTD. CONCLUSION: Real-time US can be helpful for differentiating DTD from normal thyroid parenchyma.


Assuntos
Doenças da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia , Adulto , Idoso , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tecido Parenquimatoso/diagnóstico por imagem , Tecido Parenquimatoso/patologia , Sensibilidade e Especificidade , Doenças da Glândula Tireoide/patologia , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia , Adulto Jovem
20.
AJR Am J Roentgenol ; 210(4): 734-741, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29446668

RESUMO

OBJECTIVE: The objective of our study was to evaluate the quality of virtual monoenergetic imaging (VMI) from dual-layer detector spectral CT and the effect of virtual monoenergetic images obtained at low energies on the detection of pulmonary embolism (PE) in patients with a suboptimally enhanced pulmonary artery on chest CT. MATERIALS AND METHODS: Of 1552 consecutive chest CT examinations performed with dual-layer detector spectral CT using a routine protocol with a tube voltage of 120 kVp, 79 examinations with suboptimal enhancement of the pulmonary artery (i.e., mean attenuation of pulmonary artery ≤ 180 HU) were included. The mean attenuation of the pulmonary artery, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of virtual monoenergetic images obtained at 40-200 keV were compared with those of the conventional 120-kVp images. The virtual monoenergetic images with the best CNR were compared with the 120-kVp images with regard to subjective image quality and diagnostic accuracy for detecting PE. RESULTS: Sufficient attenuation of the pulmonary artery (> 180 HU) was obtained using VMI for 78 of the 79 examinations. The noise levels of the virtual monoenergetic images were gradually increased with decreasing energy level (i.e., kiloelectron volt setting). The CNR and SNR of virtual monoenergetic images at 40-65 keV were significantly higher (both, p < 0.001) than the CNR and SNR of the 120-kVp images. The CNR was the highest at 40 keV for all cases. Diagnostic accuracy for detecting PE was significantly higher for 40-keV images (reader 1: AUC = 0.992, p = 0.033; reader 2: AUC = 0.986, p = 0.043) than for 120-kVp images (reader 1, AUC = 0.911; reader 2, AUC = 0.933). The subjective quality was not different between these two images. CONCLUSION: In chest CT examinations in which the pulmonary artery is suboptimally enhanced, obtaining virtual monoenergetic images at a low energy setting using dual-layer detector spectral CT allows sufficient attenuation of the pulmonary artery to be achieved while preserving image quality and increasing diagnostic performance for detecting PE.


Assuntos
Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa