Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Pharm Fr ; 77(2): 112-120, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30528254

RESUMO

OBJECTIVES: A novel, fast and sensitive HPLC method has been developed for the simultaneous bioanalytical determination of Donepezil hydrochloride (DON) and Citalopram hydrobromide (CTP) in raw materials, spiked human plasma and tablets. MATERIALS AND METHODS: Elution of both drugs was achieved with very good resolution using a RP-C18 chromatographic column, samples were analyzed using Hypersil Gold (100mm×4.6mm), 5µm particle size column and an isocratic binary mobile phase consists of phosphate buffer (0.05 M): acetonitrile (65:35). A Diode array detector at wavelength 232nm was used. Chromatographic separation was within a short run time (less than 7minutes) for both drugs. RESULTS: Retention times for DON and CTP were 4.5 and 5.8min, respectively. Linear calibration curves were obtained for DON and CTP over the concentration ranges of 0.1-10 and 0.1-50µg/mL. The mean extraction recoveries from spiked plasma were 93.22 and 92.64 for DON and CTP, respectively. The limits of detection and quantification were 0.017, 0.035µg/mL and 0.052, 0.106µg/mL for DON and CTP, respectively. CONCLUSION: The proposed method was successfully applied to the analysis of the cited drugs in raw materials, spiked human plasma and tablets with excellent accuracy and precision.


Assuntos
Doença de Alzheimer/tratamento farmacológico , Antidepressivos de Segunda Geração/análise , Citalopram/análise , Donepezila/análise , Nootrópicos/análise , Antidepressivos de Segunda Geração/sangue , Cromatografia Líquida de Alta Pressão , Citalopram/sangue , Donepezila/sangue , Combinação de Medicamentos , Humanos , Indicadores e Reagentes , Limite de Detecção , Nootrópicos/sangue , Plasma/química , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Comprimidos/análise
2.
Ann Pharm Fr ; 77(4): 286-294, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31027753

RESUMO

OBJECTIVES: Elderly people with dementia are commonly suffered from sleep disorders. So, the use of Donepezil hydrochloride as anti-Alzheimer drug and Trazodone hydrochloride as antidepressants with hypnotic action is very important in these cases. This study reports about novel and sensitive RP-HPLC method with fluorescence detection for simultaneous bioanalytical determination of Donepezil hydrochloride (DON) and co-administered, Trazodone hydrochloride (TRA) in their pure forms, spiked human plasma and tablets. MATERIALS AND METHODS: Elution of both drugs was achieved with excellent resolution using a RP-C18 Hypersil Gold column and an isocratic mobile phase consisting of phosphate buffer (50mm, pH 4.6): methanol: acetonitrile (60:35:5) with a flow rate of 1.5mL/min and 20µL as injection volume. A Fluorescence detector at 300nm for excitation and 400nm for emission was used. RESULTS: Retention times were 4.3 and 6.3min for Donepezil hydrochloride and Trazodone hydrochloride, respectively. Linearity ranges of the assay were 25-1000 and 50-5000ng/mL and the limits of detection (LOD) and quantitation (LOQ) were 8.52, 15.47 and 25.81, 46.89ng/mL for Donepezil hydrochloride and Trazodone hydrochloride, respectively. CONCLUSION: The high sensitivity of the proposed method enabled the successful determination of the cited drugs in spiked human plasma with mean percentage of recoveries of 91.58±3.34 and 100.30±5.11 for Donepezil hydrochloride and Trazodone hydrochloride, respectively.


Assuntos
Antidepressivos de Segunda Geração/análise , Inibidores da Colinesterase/análise , Donepezila/análise , Trazodona/análise , Antidepressivos de Segunda Geração/sangue , Inibidores da Colinesterase/sangue , Cromatografia Líquida de Alta Pressão , Donepezila/sangue , Humanos , Indicadores e Reagentes , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Fluorescência , Comprimidos , Trazodona/sangue
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa