Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Mikrochim Acta ; 190(10): 376, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37659010

RESUMO

The fabrication of a low-cost eco-friendly sensor platform for the voltammetric determination of trace metals by electrochemical stripping analysis is reported. Plastic conductive electrodes were manufactured via injection moulding from polysterene reinforced with carbon fibres. The platform comprises a carbon counter electrode, a working electrode modified with bismuth nanoparticles generated by spark discharge and a reference electrode coated with AgCl. The sensor fabrication and modification procedures are simple, cost-effective and fast while the materials used are environment-friendly. The utility of the voltammetric platform is demonstrated for stripping analysis of Cd(II) and Pb(II); the limits of detection are 0.7 µg L-1 and 0.6 µg L-1, respectively (with a deposition time of 240 s) which are comparable to conventional Bi-modified sensors and are sufficient to determine the target metals in water and food samples. The scope of the analytical platform for multi-element assays and for the determination of other trace metals is discussed with representative examples. Therefore, this sustainable and economical platform holds great potential for electrochemical sensing of trace metals.

2.
J Synchrotron Radiat ; 27(Pt 6): 1518-1527, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147177

RESUMO

A refractive phase corrector optics is proposed for the compensation of fabrication error of X-ray optical elements. Here, at-wavelength wavefront measurements of the focused X-ray beam by knife-edge imaging technique, the design of a three-dimensional corrector plate, its fabrication by 3D printing, and use of a corrector to compensate for X-ray lens figure errors are presented. A rotationally invariant corrector was manufactured in the polymer IP-STM using additive manufacturing based on the two-photon polymerization technique. The fabricated corrector was characterized at the B16 Test beamline, Diamond Light Source, UK, showing a reduction in r.m.s. wavefront error of a Be compound refractive Lens (CRL) by a factor of six. The r.m.s. wavefront error is a figure of merit for the wavefront quality but, for X-ray lenses, with significant X-ray absorption, a form of the r.m.s. error with weighting proportional to the transmitted X-ray intensity has been proposed. The knife-edge imaging wavefront-sensing technique was adapted to measure rotationally variant wavefront errors from two different sets of Be CRL consisting of 98 and 24 lenses. The optical aberrations were then quantified using a Zernike polynomial expansion of the 2D wavefront error. The compensation by a rotationally invariant corrector plate was partial as the Be CRL wavefront error distribution was found to vary with polar angle indicating the presence of non-spherical aberration terms. A wavefront correction plate with rotationally anisotropic thickness is proposed to compensate for anisotropy in order to achieve good focusing by CRLs at beamlines operating at diffraction-limited storage rings.

3.
Sensors (Basel) ; 19(21)2019 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-31694252

RESUMO

This work describes a novel electrochemical sensor fabricated by an injection molding process. This device features a conductive polymer electrode encased in a plastic holder and electroplated in situ with a thin antimony film. The antimony film sensor was applied to the determination of Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The deposition of Sb on the sensor was studied by cyclic voltammetry (CV) and microscopy. The experimental variables (concentration of the antimony plating solution, deposition potential and time, stripping waveform) were investigated, and the potential interferences were studied and addressed. The limits of detection were 0.95 µg L-1 for Pb(II) and 1.3 for Cd(II) (at 240 s of preconcentration) and the within-sensor percentage relative standard deviations were 4.2% and 4.9%, respectively, at the 25 µg L-1 level (n = 8). Finally, the sensor was applied to the determination of Pb(II) and Cd(II) in a phosphorite sample and a lake water sample.

4.
Genes Chromosomes Cancer ; 53(3): 255-63, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24339206

RESUMO

A simple microfluidic fluorescence in situ hybridization (FISH) device allowing accurate analysis of interphase nuclei in 1 hr in narrow channels is presented. Photolithography and fluorosilicic acid etching were used to fabricate microfluidic channels (referred to as FISHing lines) that allowed analysis of 10 samples on a glass microscope slide 0.2 µl of sample volume was used to fill a micro-channel, which resembled a 250-fold reduction compared to conventional FISH. FISH signals were comparable to conventional FISH, with 50-fold less probe consumption and 10-fold less time. Cells were immobilized in single file in channels just exceeding the diameter of the cells, and were used for minimal residual disease (MRD) analysis. To test the micro-channels for application in FISH, MRD was simulated by mixing K562 cells (an established chronic myeloid leukemia cell line) carrying the BCR/ABL fusion gene across 1:1 to 1:1,000 Jurkat cells (an established acute lymphoblastic leukemia cell line). The limit of detection was seen to be 1:100 cells and 1:1,000 cells for FISHing lines and conventional FISH, respectively; however, the conventional method seemed to over-score the presence of K562 cells. This may in part be attributed to FISHing lines practically eliminating the chance of duplicate screening of cells and hastened the time of screening, enhancing scoring of all cells within the channels. This was compared to 1 in 500 cells on the slide being analyzed with the conventional FISH.


Assuntos
Neoplasias Hematológicas/diagnóstico , Hibridização in Situ Fluorescente/métodos , Tamanho Celular , Neoplasias Hematológicas/patologia , Humanos , Células Jurkat , Células K562 , Microfluídica , Neoplasia Residual
5.
Nat Commun ; 15(1): 3013, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589362

RESUMO

Hard carbon is a promising negative electrode material for rechargeable sodium-ion batteries due to the ready availability of their precursors and high reversible charge storage. The reaction mechanisms that drive the sodiation properties in hard carbons and subsequent electrochemical performance are strictly linked to the characteristic slope and plateau regions observed in the voltage profile of these materials. This work shows that electron paramagnetic resonance (EPR) spectroscopy is a powerful and fast diagnostic tool to predict the extent of the charge stored in the slope and plateau regions during galvanostatic tests in hard carbon materials. EPR lineshape simulation and temperature-dependent measurements help to separate the nature of the spins in mechanochemically modified hard carbon materials synthesised at different temperatures. This proves relationships between structure modification and electrochemical signatures in the galvanostatic curves to obtain information on their sodium storage mechanism. Furthermore, through ex situ EPR studies we study the evolution of these EPR signals at different states of charge to further elucidate the storage mechanisms in these carbons. Finally, we discuss the interrelationship between EPR spectroscopy data of the hard carbon samples studied and their corresponding charging storage mechanism.

6.
Talanta ; 265: 124850, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37354623

RESUMO

Mercury is a toxic environmental contaminant that can cause serious health problems. This work describes a new type of eco-friendly three-electrode plastic sensor chip for the determination of trace Hg(II) by means of anodic stripping voltammetry (ASV). The sensor chip is entirely fabricated by injection moulding, which is a sustainable manufacturing method, and consists of three conductive carbon-based electrodes embedded in a plastic holder while the reference electrode is coated with Ag using e-beam evaporation. The sample is spiked with Au(III) which deposits on the working electrode in the form of gold nanoparicles during the analysis; the target Hg(II) co-deposits on the gold nanoparticles forming a Au(Hg) amalgam in situ. The accumulated Hg is stripped off the electrode and quantified by an anodic square wave potential scan. The relevant conditions and the potential interferences are investigated. The limit of detection for Hg(II) is 0.4 µg L-1 and the repeatability at the 20 µg L-1 Hg(III) level (n = 10) is 5.3%. The sensor is applied to water, honey, fish oil and mussel samples with recoveries between 98 and 107%.

7.
Nat Commun ; 14(1): 4582, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524749

RESUMO

Visible light optical elements such as lenses and mirrors have counterparts for X-rays. In the visible regime, a variable focusing power can be achieved by an Alvarez lens which consists of a pair of inline planar refractors with a cubic thickness profile. When the two refractors are laterally displaced in opposite directions, the parabolic component of the wavefront is changed resulting in a longitudinal displacement of the focus. This paper reports an implementation of this concept for X-rays using two planar microfabricated refractive elements. The Alvarez X-ray lens can vary the focal distance of an elliptical X-ray mirror or a planar compound X-ray lens over several millimetres. The study presents the first demonstration of an Alvarez X-ray lens which adaptively corrects defocus and astigmatism aberrations of X-ray optics. In addition, the Alvarez X-ray lens eliminates coma aberration in an elliptical mirror, to the lowest order, when combining the lens with an adjustment of the pitch angle of the mirror.

8.
Sci Rep ; 13(1): 10809, 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37402736

RESUMO

Fourier domain optical coherence tomography (FD-OCT) is a well-established imaging technique that provides high-resolution internal structure images of an object at a fast speed. Modern FD-OCT systems typically operate at speeds of 40,000-100,000 A-scans/s, but are priced at least tens of thousands of pounds. In this study, we demonstrate a line-field FD-OCT (LF-FD-OCT) system that achieves an OCT imaging speed of 100,000 A-scan/s at a hardware cost of thousands of pounds. We demonstrate the potential of LF-FD-OCT for biomedical and industrial imaging applications such as corneas, 3D printed electronics, and printed circuit boards.

9.
Polymers (Basel) ; 14(22)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36433079

RESUMO

Electroactive hydrogels based on derivatives of polyethyleneglycol (PEG), chitosan and polypyrrole were prepared via a combination of photopolymerization and oxidative chemical polymerization, and optionally doped with anions (e.g., lignin, drugs, etc.). The products were analyzed with a variety of techniques, including: FT-IR, UV-Vis, 1H NMR (solution state), 13C NMR (solid state), XRD, TGA, SEM, swelling ratios and rheology. The conductive gels swell ca. 8 times less than the non-conductive gels due to the presence of the interpenetrating network (IPN) of polypyrrole and lignin. A rheological study showed that the non-conductive gels are soft (G' 0.35 kPa, G″ 0.02 kPa) with properties analogous to brain tissue, whereas the conductive gels are significantly stronger (G' 30 kPa, G″ 19 kPa) analogous to breast tissue due to the presence of the IPN of polypyrrole and lignin. The potential of these biomaterials to be used for biomedical applications was validated in vitro by cell culture studies (assessing adhesion and proliferation of fibroblasts) and drug delivery studies (electrochemically loading the FDA-approved chemotherapeutic pemetrexed and measuring passive and stimulated release); indeed, the application of electrical stimulus enhanced the release of PEM from gels by ca. 10-15% relative to the passive release control experiment for each application of electrical stimulation over a short period analogous to the duration of stimulation applied for electrochemotherapy. It is foreseeable that such materials could be integrated in electrochemotherapeutic medical devices, e.g., electrode arrays or plates currently used in the clinic.

10.
Analyst ; 136(15): 3170-6, 2011 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-21674078

RESUMO

A new method has been developed to improve the determination of thiocyanate using isotachophoresis. This method uses complexation with copper(II) as a mechanism for improving the separation of thiocyanate from chlorate and perchlorate. By using a pH of 3.25 the method can also be used to analyse nitrite. Separations were carried out using a miniaturised poly(methyl methacrylate) (PMMA) separation device. Linearity was observed from 1.25 to 75 mg dm(-3) with a correlation coefficient of 0.998 for both thiocyanate and nitrite. Limits of detection for these two species were calculated to be 0.8 mg dm(-3) and 0.9 mg dm(-3) respectively. The method was successfully applied to the analysis of these anions in a range of samples including explosive residues.

11.
Microorganisms ; 9(4)2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33806176

RESUMO

Suitable immobilisation of microorganisms and single cells is key for high-resolution topographical imaging and study of mechanical properties with atomic force microscopy (AFM) under physiologically relevant conditions. Sample preparation techniques must be able to withstand the forces exerted by the Z range-limited cantilever tip, and not negatively affect the sample surface for data acquisition. Here, we describe an inherently flexible methodology, utilising the high-resolution three-dimensional based printing technique of multiphoton polymerisation to rapidly generate bespoke arrays for cellular AFM analysis. As an example, we present data collected from live Emiliania huxleyi cells, unicellular microalgae, imaged by contact mode High-Speed Atomic Force Microscopy (HS-AFM), including one cell that was imaged continuously for over 90 min.

12.
Electrophoresis ; 31(22): 3775-82, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21077244

RESUMO

A new method has been developed to allow the determination of potassium in post-explosion residues to be made using miniaturised isotachophoresis. The method is based on the use of a caesium leading ion with 4.5 mM 18-crown-6 ether added to retard the potassium to allow reliable determinations to be made. With the conditions selected no interference was noted from other small inorganic cations, such as ammonium, barium, calcium, magnesium, sodium or strontium. The method was successfully applied to the analysis of seven samples containing explosive residues obtained from the unconfined burning of several flash powders. The procedure was found to offer good linearity for potassium determinations over the concentration range of 1.25-150 µg/mL with a coefficient of determination of 0.999 achieved.


Assuntos
Eletroforese em Microchip/métodos , Substâncias Explosivas/química , Isotacoforese/métodos , Potássio/análise , Cátions/análise , Éteres de Coroa/química , Eletroforese em Microchip/instrumentação , Isotacoforese/instrumentação , Modelos Lineares , Sensibilidade e Especificidade
13.
RSC Adv ; 10(19): 11060-11073, 2020 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35495315

RESUMO

Materials capable of releasing reactive oxygen species (ROS) can display antibacterial and anticancer activity, and may also have anti-oxidant capacity if they suppress intracellular ROS (e.g. nitric oxide, NO) resulting in anti-inflammatory activity. Herein we report silver phosphate (Ag3PO4)/polyindole (Pln) nanocomposites which display antibacterial, anticancer and anti-inflammatory activity, and have therefore potential for a variety of biomedical applications.

14.
Lab Chip ; 9(13): 1882-9, 2009 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-19532963

RESUMO

This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet eleven-outlet (2-11) network design. The mathematical approach has been validated experimentally using a purpose built optical detection system. The experimental results are shown to be in very good agreement with the theoretical predictions from the model. The developed networks are proven to deliver precise linear concentration gradients (R(2) = 0.9973 and 0.9991 for the (2-6) designs) and the simplified networks are shown to provide enhanced performance over conventional designs, overcoming some of the practical issues associated with traditional networks. The optical measurements were precise enough to validate the linearity in each level of the conventional (2-6) networks (R(2) ranged from 0.9999 to 0.9973) compared to R(2) = 1 for the theoretical model. CFD results show that there is an effective upper limit on the operating flow rate. The new simplified (2-11) design was able to maintain a linear outlet profile up to 0.8 microl/s per inlet (R(2) = 0.9992). The proposed approach is widely applicable for the production of linear and arbitrary concentration profiles, with the potential for high throughput applications that span a wide range of chemical and biological studies.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Soluções/química , Simulação por Computador , Desenho de Equipamento , Modelos Teóricos , Dispositivos Ópticos
15.
Anal Bioanal Chem ; 394(5): 1299-305, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19205676

RESUMO

The use of malonic acid as a complexing agent has enabled a new method to be devised to allow the determination of magnesium to be made using miniaturised isotachophoresis. Using a leading electrolyte of 10 mmol L(-1) caesium hydroxide and 2 mmol L(-1) malonic acid at pH 5.1 gave the method a high specificity towards magnesium. Investigations using a poly(methyl methacrylate) chip device with an integrated conductivity detector showed that no interference from calcium, strontium, barium and sodium should occur. The method was found to be linear over the range of magnesium concentrations from 0.625 to 75 mg L(-1) and the limit of detection was calculated to be 0.45 mg L(-1). Separations were demonstrated with water samples but the procedure should also be applicable to more complex sample matrices such as inorganic explosive residues, blood or urine.

16.
Materials (Basel) ; 12(23)2019 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-31783647

RESUMO

Hybrid organometallic polymers are a class of functional materials which can be used to produce structures with sub-micron features via laser two-photon polymerisation. Previous studies demonstrated the relative biocompatibility of Al and Zr containing hybrid organometallic polymers in vitro. However, a deeper understanding of their effects on intracellular processes is needed if a tissue engineering strategy based on these materials is to be envisioned. Herein, primary rat myogenic cells were cultured on spin-coated Al and Zr containing polymer surfaces to investigate how each material affects the viability, adhesion strength, adhesion-associated protein expression, rate of cellular metabolism and collagen secretion. We found that the investigated surfaces supported cellular growth to full confluency. A subsequent MTT assay showed that glass and Zr surfaces led to higher rates of metabolism than did the Al surfaces. A viability assay revealed that all surfaces supported comparable levels of cell viability. Cellular adhesion strength assessment showed an insignificantly stronger relative adhesion after 4 h of culture than after 24 h. The largest amount of collagen was secreted by cells grown on the Al-containing surface. In conclusion, the materials were found to be biocompatible in vitro and have potential for bioengineering applications.

17.
J Chromatogr A ; 1195(1-2): 157-63, 2008 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-18513732

RESUMO

A new method has been developed to allow the determination of the chlorate, chloride and perchlorate anions in inorganic explosive residues to be made using isotachophoresis (ITP). To enable a good separation of these species to be achieved the method involves the use of two complexing agents. Indium(III) is used to allow the determination of chloride whilst using nitrate as the leading ion and alpha-cyclodextrin is used to allow the separation of chlorate and perchlorate. Separations were carried out using a miniaturised poly(methyl methacrylate) (PMMA) separation device. The method was applied to analysing both model samples and actual inorganic explosive containing residue samples. Successful determinations of these samples were achieved with no interference from other anions typically found in inorganic explosive residues. Limits of detection (LOD) for the species of interest were calculated to be 0.80 mg l(-1) for chloride, 1.75 mg l(-1) for chlorate and 1.40 mg l(-1) for perchlorate.


Assuntos
Cloro/análise , Eletroforese/métodos , Substâncias Explosivas/análise , Cloratos/análise , Cloratos/isolamento & purificação , Cloretos/análise , Cloretos/isolamento & purificação , Cloro/isolamento & purificação , Substâncias Explosivas/isolamento & purificação , Índio/química , Percloratos/análise , Percloratos/isolamento & purificação , Polimetil Metacrilato/química , Reprodutibilidade dos Testes , alfa-Ciclodextrinas/química
18.
Anal Bioanal Chem ; 391(4): 1283-92, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18351328

RESUMO

Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a "mercury-free" AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.

19.
Materials (Basel) ; 11(7)2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29966387

RESUMO

The delivery of drugs in a controllable fashion is a topic of intense research activity in both academia and industry because of its impact in healthcare. Implantable electronic interfaces for the body have great potential for positive economic, health, and societal impacts; however, the implantation of such interfaces results in inflammatory responses due to a mechanical mismatch between the inorganic substrate and soft tissue, and also results in the potential for microbial infection during complex surgical procedures. Here, we report the use of conducting polypyrrole (PPY)-based coatings loaded with clinically relevant drugs (either an anti-inflammatory, dexamethasone phosphate (DMP), or an antibiotic, meropenem (MER)). The films were characterized and were shown to enhance the delivery of the drugs upon the application of an electrochemical stimulus in vitro, by circa (ca.) 10⁻30% relative to the passive release from non-stimulated samples. Interestingly, the loading and release of the drugs was correlated with the physical descriptors of the drugs. In the long term, such materials have the potential for application to the surfaces of medical devices to diminish adverse reactions to their implantation in vivo.

20.
J Chromatogr A ; 1155(2): 199-205, 2007 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-17229431

RESUMO

An injection moulded free flow isotachophoresis (FFITP) microdevice with integrated carbon fibre loaded electrodes with a separation chamber of 36.4mm wide, 28.7 mm long and 100 microm deep is presented. The microdevice was completely fabricated by injection moulding in carbon fibre loaded polystyrene for the electrodes and crystal polystyrene for the remainder of the chip and was bonded together using ultrasonic welding. Two injection moulded electrode designs were compared, one with the electrode surface level with the separation chamber and one with a recessed electrode. Separations of two anionic dyes, 0.2mM each of amaranth and acid green and separations of 0.2mM each of amaranth, bromophenol blue and glutamate were performed on the microdevice. Flow rates of 1.25 ml min(-1) for the leading and terminating electrolytes were used and a flow rate of 0.63 ml min(-1) for the sample. Electric fields of up to 370 V cm(-1) were applied across the separation chamber. Joule heating was not found to be significant although out-gassing was observed at drive currents greater than 3 mA.


Assuntos
Eletroforese/instrumentação , Eletroforese/métodos , Eletrodos , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Miniaturização
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa