Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Radiology ; 311(2): e233136, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742971

RESUMO

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Reprodutibilidade dos Testes , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cirrose Hepática/diagnóstico por imagem
2.
AJR Am J Roentgenol ; 222(3): e2329418, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37315018

RESUMO

MRI plays an important role in the evaluation of kidney allografts for vascular complications as well as parenchymal insults. Transplant renal artery stenosis, the most common vascular complication of kidney transplant, can be evaluated by MRA using gadolinium and nongadolinium contrast agents as well as by unenhanced MRA techniques. Parenchymal injury occurs through a variety of pathways, including graft rejection, acute tubular injury, BK polyomavirus infection, drug-induced interstitial nephritis, and pyelonephritis. Investigational MRI techniques have sought to differentiate among these causes of dysfunction as well as to assess the degree of interstitial fibrosis or tubular atrophy (IFTA)-the common end pathway for all of these processes-which is currently evaluated by invasively obtained core biopsies. Some of these MRI sequences have shown promise in not only assessing the cause of parenchymal injury but also assessing IFTA noninvasively. This review describes current clinically used MRI techniques and previews promising investigational MRI techniques for assessing complications of kidney grafts.


Assuntos
Nefropatias , Rim , Humanos , Constrição Patológica , Rim/patologia , Fibrose , Nefropatias/etiologia , Rejeição de Enxerto/diagnóstico por imagem , Aloenxertos/patologia , Imageamento por Ressonância Magnética/efeitos adversos
3.
J Magn Reson Imaging ; 58(2): 342-359, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37052601

RESUMO

Solid renal masses (SRMs) are increasingly detected and encompass both benign and malignant masses, with renal cell carcinoma (RCC) being the most common malignant SRM. Most patients with SRMs will undergo management without a priori pathologic confirmation. There is an unmet need to noninvasively diagnose and characterize RCCs, as significant variability in clinical behavior is observed and a wide range of differing management options exist. Cross-sectional imaging modalities, including magnetic resonance imaging (MRI), are increasingly used for SRM characterization. Multiparametric (mp) MRI techniques can provide insight into tumor biology by probing different physiologic/pathophysiologic processes noninvasively. These include sequences that probe tissue microstructure, including intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and T1 relaxometry; oxygen metabolism (blood oxygen level dependent [BOLD-MRI]); as well as vascular flow and perfusion (dynamic contrast-enhanced MRI [DCE-MRI] and arterial spin labeling [ASL]). In this review, we will discuss each mpMRI method in terms of its principles, roles, and discuss the results of human studies for SRM assessment. Future validation of these methods may help to enable a personalized management approach for patients with SRM in the emerging era of precision medicine. EVIDENCE LEVEL: 5. TECHNICAL EFFICACY: 2.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Movimento (Física)
4.
J Magn Reson Imaging ; 58(6): 1660-1679, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37243378

RESUMO

Renal diseases pose a significant socio-economic burden on healthcare systems. The development of better diagnostics and prognostics is well-recognized as a key strategy to resolve these challenges. Central to these developments are MRI biomarkers, due to their potential for monitoring of early pathophysiological changes, renal disease progression or treatment effects. The surge in renal MRI involves major cross-domain initiatives, large clinical studies, and educational programs. In parallel with these translational efforts, the need for greater (patho)physiological specificity remains, to enable engagement with clinical nephrologists and increase the associated health impact. The ISMRM 2022 Member Initiated Symposium (MIS) on renal MRI spotlighted this issue with the goal of inspiring more solutions from the ISMRM community. This work is a summary of the MIS presentations devoted to: 1) educating imaging scientists and clinicians on renal (patho)physiology and demands from clinical nephrologists, 2) elucidating the connection of MRI parameters with renal physiology, 3) presenting the current state of leading MR surrogates in assessing renal structure and functions as well as their next generation of innovation, and 4) describing the potential of these imaging markers for providing clinically meaningful renal characterization to guide or supplement clinical decision making. We hope to continue momentum of recent years and introduce new entrants to the development process, connecting (patho)physiology with (bio)physics, and conceiving new clinical applications. We envision this process to benefit from cross-disciplinary collaboration and analogous efforts in other body organs, but also to maximally leverage the unique opportunities of renal physiology. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Nefropatias , Rim , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nefropatias/diagnóstico por imagem , Néfrons , Testes de Função Renal
5.
BJU Int ; 132(1): 75-83, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36797809

RESUMO

OBJECTIVE: To profile the cell-free urine supernatant and plasma of a small cohort of clear-cell renal cell carcinoma (ccRCC) patients by measuring the relative concentrations of 92 proteins related to inflammation. Using The Cancer Genome Atlas (TCGA), we then performed a targeted mRNA analysis of genes encoding the above proteins and defined their effects on overall survival (OS). SUBJECTS/PATIENTS AND METHODS: Samples were collected prospectively from ccRCC patients. A multiplex proximity extension assay was used to measure the concentrations of 92 inflammation-related proteins in cell-free urine supernatants and plasma. Transcriptomic and clinical information from ccRCC patients was obtained from TCGA. Unsupervised clustering and differential protein expression analyses were performed on protein concentration data. Targeted mRNA analysis on genes encoding significant differentially expressed proteins was performed using TCGA. Backward stepwise regression analyses were used to build a nomogram. The performance of the nomogram and clinical benefit was assessed by discrimination and calibration, and a decision curve analysis, respectively. RESULTS: Unsupervised clustering analysis revealed inflammatory signatures in the cell-free urine supernatant of ccRCC patients. Backward stepwise regressions using TCGA data identified transcriptomic risk factors and risk groups associated with OS. A nomogram to predict 2-year and 5-year OS was developed using these risk factors. The decision curve analysis showed that our model was associated with a net benefit improvement compared to the treat-all/none strategies. CONCLUSION: We defined four novel biomarkers using proteomic and transcriptomic data that distinguish severity of prognosis in ccRCC. We showed that these biomarkers can be used in a model to predict 2-year and 5-year OS in ccRCC across different tumour stages. This type of analysis, if validated in the future, provides non-invasive prognostic information that could inform either management or surveillance strategies for patients.


Assuntos
Carcinoma de Células Renais , Carcinoma , Neoplasias Renais , Humanos , Carcinoma de Células Renais/genética , Proteômica , Inflamação , Neoplasias Renais/genética , Prognóstico
6.
Eur Radiol ; 33(9): 6020-6032, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37071167

RESUMO

OBJECTIVE: To assess the performance of convolutional neural networks (CNNs) for semiautomated segmentation of hepatocellular carcinoma (HCC) tumors on MRI. METHODS: This retrospective single-center study included 292 patients (237 M/55F, mean age 61 years) with pathologically confirmed HCC between 08/2015 and 06/2019 and who underwent MRI before surgery. The dataset was randomly divided into training (n = 195), validation (n = 66), and test sets (n = 31). Volumes of interest (VOIs) were manually placed on index lesions by 3 independent radiologists on different sequences (T2-weighted imaging [WI], T1WI pre-and post-contrast on arterial [AP], portal venous [PVP], delayed [DP, 3 min post-contrast] and hepatobiliary phases [HBP, when using gadoxetate], and diffusion-weighted imaging [DWI]). Manual segmentation was used as ground truth to train and validate a CNN-based pipeline. For semiautomated segmentation of tumors, we selected a random pixel inside the VOI, and the CNN provided two outputs: single slice and volumetric outputs. Segmentation performance and inter-observer agreement were analyzed using the 3D Dice similarity coefficient (DSC). RESULTS: A total of 261 HCCs were segmented on the training/validation sets, and 31 on the test set. The median lesion size was 3.0 cm (IQR 2.0-5.2 cm). Mean DSC (test set) varied depending on the MRI sequence with a range between 0.442 (ADC) and 0.778 (high b-value DWI) for single-slice segmentation; and between 0.305 (ADC) and 0.667 (T1WI pre) for volumetric-segmentation. Comparison between the two models showed better performance in single-slice segmentation, with statistical significance on T2WI, T1WI-PVP, DWI, and ADC. Inter-observer reproducibility of segmentation analysis showed a mean DSC of 0.71 in lesions between 1 and 2 cm, 0.85 in lesions between 2 and 5 cm, and 0.82 in lesions > 5 cm. CONCLUSION: CNN models have fair to good performance for semiautomated HCC segmentation, depending on the sequence and tumor size, with better performance for the single-slice approach. Refinement of volumetric approaches is needed in future studies. KEY POINTS: • Semiautomated single-slice and volumetric segmentation using convolutional neural networks (CNNs) models provided fair to good performance for hepatocellular carcinoma segmentation on MRI. • CNN models' performance for HCC segmentation accuracy depends on the MRI sequence and tumor size, with the best results on diffusion-weighted imaging and T1-weighted imaging pre-contrast, and for larger lesions.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação
7.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33140551

RESUMO

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Rim , Imageamento por Ressonância Magnética , Consenso , Técnica Delphi , Humanos , Estudos Multicêntricos como Assunto , Circulação Renal
8.
Eur Radiol ; 32(9): 6493-6503, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35380226

RESUMO

BACKGROUND AND AIMS: Transarterial 90Y radioembolization (TARE) is increasingly being used for hepatocellular carcinoma (HCC) treatment. However, tumor response assessment after TARE may be challenging. We aimed to assess the diagnostic performance of gadoxetate disodium MRI for predicting complete pathologic necrosis (CPN) of HCC treated with TARE, using histopathology as the reference standard. METHODS: This retrospective study included 48 patients (M/F: 36/12, mean age: 62 years) with HCC treated by TARE followed by surgery with gadoxetate disodium MRI within 90 days of surgery. Two radiologists evaluated tumor response using RECIST1.1, mRECIST, EASL, and LI-RADS-TR criteria and evaluated the percentage of necrosis on subtraction during late arterial, portal venous, and hepatobiliary phases (AP/PVP/HBP). Statistical analysis included inter-reader agreement, correlation between radiologic and pathologic percentage of necrosis, and prediction of CPN using logistic regression and ROC analyses. RESULTS: Histopathology demonstrated 71 HCCs (2.8 ± 1.7 cm, range: 0.5-7.5 cm) including 42 with CPN, 22 with partial necrosis, and 7 without necrosis. EASL and percentage of tumor necrosis on subtraction at the AP/PVP were independent predictors of CPN (p = 0.02-0.03). Percentage of necrosis, mRECIST, EASL, and LI-RADS-TR had fair to good performance for diagnosing CPN (AUCs: 0.78 - 0.83), with a significant difference between subtraction and LI-RADS-TR for reader 2, and in specificity between subtraction and other criteria for both readers (p-range: 0.01-0.04). Radiologic percentage of necrosis was significantly correlated to histopathologic degree of tumor necrosis (r = 0.66 - 0.8, p < 0.001). CONCLUSIONS: Percentage of tumor necrosis on subtraction and EASL criteria were significant independent predictors of CPN in HCC treated with TARE. Image subtraction should be considered for assessing HCC response to TARE when using MRI. KEY POINTS: • Percentage of tumor necrosis on image subtraction and EASL criteria are significant independent predictors of complete pathologic necrosis in hepatocellular carcinoma treated with90Y radioembolization. • Subtraction, mRECIST, EASL, and LI-RADS-TR have fair to good performance for diagnosing complete pathologic necrosis in hepatocellular carcinoma treated with90Y radioembolization.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/radioterapia , Gadolínio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Necrose , Estudos Retrospectivos , Radioisótopos de Ítrio
9.
Eur Radiol ; 32(3): 2030-2040, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34564745

RESUMO

OBJECTIVES: To assess the precision of MRI radiomics features in hepatocellular carcinoma (HCC) tumors and liver parenchyma. METHODS: The study population consisted of 55 patients, including 16 with untreated HCCs, who underwent two repeat contrast-enhanced abdominal MRI exams within 1 month to evaluate: (1) test-retest repeatability using the same MRI system (n = 28, 10 HCCs); (2) inter-platform reproducibility between different MRI systems (n = 27, 6 HCCs); (3) inter-observer reproducibility (n = 16, 16 HCCs). Shape and 1st- and 2nd-order radiomics features were quantified on pre-contrast T1-weighted imaging (WI), T1WI portal venous phase (pvp), T2WI, and ADC (apparent diffusion coefficient), on liver regions of interest (ROIs) and HCC volumes of interest (VOIs). Precision was assessed by calculating intraclass correlation coefficient (ICC), concordance correlation coefficient (CCC), and coefficient of variation (CV). RESULTS: There was moderate to excellent test-retest repeatability of shape and 1st- and 2nd-order features for all sequences in HCCs (ICC: 0.53-0.99; CV: 3-29%), and moderate to good test-retest repeatability of 1st- and 2nd-order features for T1WI sequences, and 2nd-order features for T2WI in the liver (ICC: 0.53-0.73; CV: 12-19%). There was poor inter-platform reproducibility for all features and sequences, except for shape and 1st-order features on T1WI in HCCs (CCC: 0.58-0.99; CV: 3-15%). Good to excellent inter-observer reproducibility was found for all features and sequences in HCCs (CCC: 0.80-0.99; CV: 4-15%) and moderate to good for liver (CCC: 0.45-0.86; CV: 6-25%). CONCLUSIONS: MRI radiomics features have acceptable repeatability in the liver and HCC when using the same MRI system and across readers but have low reproducibility across MR systems, except for shape and 1st-order features on T1WI. Data must be interpreted with caution when performing multiplatform radiomics studies. KEY POINTS: • MRI radiomics features have acceptable repeatability when using the same MRI system but less reproducible when using different MRI platforms. • MRI radiomics features extracted from T1 weighted-imaging show greater stability across exams than T2 weighted-imaging and ADC. • Inter-observer reproducibility of MRI radiomics features was found to be good in HCC tumors and acceptable in liver parenchyma.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Eur Radiol ; 32(12): 8339-8349, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35727321

RESUMO

OBJECTIVES: Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference. METHODS: In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement. The correlation between MRE/SWE measures of LS/SS and spleen volume with HVPG was assessed. ROC analysis was used to determine the utility of MRE, SWE, and spleen volume for diagnosing CSPH. RESULTS: Thirty-six patients (M/F 22/14, mean age 55 ± 14 years) were included. Of the evaluated parameters, 3D MRE SS had the strongest correlation with HVPG (r = 0.686, p < 0.001), followed by 2D MRE SS (r = 0.476, p = 0.004). 3D MRE SS displayed the best performance for diagnosis of CSPH (AUC = 0.911) followed by 2D MRE SS (AUC = 0.845) and 3D MRE LS (AUC = 0.804). SWE SS showed poor performance for diagnosis of CSPH (AUC = 0.583) while spleen volume was a fair predictor (AUC = 0.738). 3D MRE SS was significantly superior to SWE LS/SS (p ≤ 0.021) for the diagnosis of CSPH. CONCLUSION: SS measured with 3D MRE outperforms SWE for the diagnosis of CSPH. SS appears to be a useful biomarker for assessing PH severity. These results need further validation. KEY POINTS: • Spleen stiffness measured with 2D and 3D MR elastography correlates significantly with hepatic venous pressure gradient measurement. • Spleen stiffness measured with 3D MR elastography demonstrates excellent performance for the diagnosis of clinically significant portal hypertension (AUC 0.911). • Spleen stiffness measured with 3D MR elastography outperforms liver and spleen stiffness measured with shear wave elastography for diagnosis of clinically significant portal hypertension.


Assuntos
Técnicas de Imagem por Elasticidade , Hipertensão Portal , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Cirrose Hepática/complicações , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/patologia , Pressão na Veia Porta , Fígado/patologia
11.
Eur Radiol ; 31(8): 5791-5801, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33475773

RESUMO

OBJECTIVES: To quantify hepatocellular carcinoma (HCC) and liver parenchyma stiffness using MR elastography (MRE) and serum alpha fetoprotein (AFP), before and 6 weeks (6w) after 90Y radioembolisation (RE), and to assess the value of baseline tumour and liver stiffness (TS/LS) and AFP in predicting response at 6w and 6 months (6 m). METHODS: Twenty-three patients (M/F 18/5, mean age 68.3 ± 9.3 years) scheduled to undergo RE were recruited into this prospective single-centre study. Patients underwent an MRI exam at baseline and 6w following RE (range 39-47 days) which included MRE using a prototype 2D EPI sequence. TS, peritumoural LS/LS remote from the tumour, tumour size, and AFP were measured at baseline and at 6w. Treatment response was determined using mRECIST at 6w and 6 m. RESULTS: MRE was technically successful in 17 tumours which were classified at 6w as complete response (CR, n = 7), partial response (PR, n = 4), and stable disease (SD, n = 6). TS and peritumoural LS were significantly increased following RE (p = 0.016, p = 0.039, respectively), while LS remote from tumour was unchanged (p = 0.245). Baseline TS was significantly lower in patients who achieved CR at 6w (p = 0.014). Baseline TS, peritumoural LS (both AUC = 0.857), and AFP (AUC = 0.798) showed fair/excellent diagnostic performance in predicting CR at 6w, but were not significant predictors of OR or CR at 6 m. CONCLUSION: Our initial results suggest that HCC TS and peritumoural LS increase early after RE. Baseline TS, peritumoural LS, and AFP were all significant predictors of CR to RE at 6w. These results should be confirmed in a larger study. KEY POINTS: • Magnetic resonance elastography-derived tumour stiffness and peritumoural liver stiffness increase significantly at 6 weeks post radioembolisation whereas liver stiffness remote from the tumour is unchanged. • Baseline tumour stiffness and peritumoural liver stiffness are lower in patients who achieve complete response at 6 weeks post radioembolisation. • Baseline tumour size is significantly correlated with baseline tumour stiffness.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Eur Radiol ; 31(7): 4804-4812, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33411050

RESUMO

OBJECTIVES: To assess the performance of gadoxetate dynamic contrast-enhanced (DCE) MRI of the liver and spleen for noninvasive diagnosis of portal hypertension (PH). METHODS: Thirty-five patients (M/F 22/13, mean age 55 years) with chronic liver disease who underwent hepatic venous pressure gradient (HVPG) measurements were prospectively enrolled in this IRB-approved study. All patients underwent multiparametric MRI including gadoxetate DCE-MRI acquisition. Model-based and model-free DCE-MRI analyses were performed. The correlation between DCE-MRI parameters and HVPG was assessed. ROC analysis was employed to determine the diagnostic performance of DCE-MRI parameters alone and in combination for prediction of PH and clinically significant (CS)PH (HVPG > 5 and ≥ 10 mmHg, respectively). RESULTS: Mean HVPG was 7.0 ± 5.0 mmHg (range 0-18 mmHg). Twenty-one (60%) patients had PH, of whom 9 had CSPH. Modeled liver uptake fraction fi and uptake rate ki and model-free parameters liver upslope and uptake were all significantly negatively correlated with HVPG (r range - 0.490 to - 0.398, p value range 0.003-0.018), while spleen interstitial fraction ve was significantly positively correlated with HVPG (r = 0.336, p = 0.048). For PH diagnosis, liver ki showed the best diagnostic performance with an AUC, sensitivity, and specificity of 0.74 (confidence interval (CI) 0.57-0.91), 71.4%, and 78.6%. The combination of liver ki and spleen ve was selected as the best classifier for diagnosis of CSPH with an AUC, sensitivity, and specificity of 0.87 (CI 0.75-0.99), 100%, and 73.1%. CONCLUSIONS: Our results demonstrate the potential utility of hepatocyte uptake parameters and spleen interstitial fraction obtained with gadoxetate DCE-MRI for the diagnosis of PH and CSPH. KEY POINTS: • Liver uptake and spleen interstitial fraction estimates from gadoxetate DCE-MRI are significantly correlated with portal pressure measurements. • Liver uptake rate shows good diagnostic performance for the diagnosis of portal hypertension. • The combination of liver uptake rate with spleen interstitial fraction exhibits excellent diagnostic performance for the diagnosis of clinically significant portal hypertension.


Assuntos
Técnicas de Imagem por Elasticidade , Hipertensão Portal , Humanos , Hipertensão Portal/diagnóstico por imagem , Fígado/diagnóstico por imagem , Cirrose Hepática , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Pressão na Veia Porta , Baço/diagnóstico por imagem
13.
Eur Radiol ; 31(2): 909-919, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32870395

RESUMO

OBJECTIVES: (1) Determine inter-observer reproducibility and test-retest repeatability of 4D flow parameters in renal allograft vessels; (2) determine if 4D flow measurements in the renal artery (RA) and renal vein (RV) can distinguish between functional and dysfunctional allografts; (3) correlate haemodynamic parameters with estimated glomerular filtration rate (eGFR), perfusion measured with dynamic contrast-enhanced MRI (DCE-MRI) and histopathology. METHODS: Twenty-five prospectively recruited renal transplant patients (stable function/chronic renal allograft dysfunction, 12/13) underwent 4D flow MRI at 1.5 T. 4D flow coronal oblique acquisitions were performed in the transplant renal artery (RA) (velocity encoding parameter, VENC = 120 cm/s) and renal vein (RV) (VENC = 45 cm/s). Test-retest repeatability (n = 3) and inter-observer reproducibility (n = 10) were assessed by Cohen's kappa, coefficient of variation (CoV) and Bland-Altman statistics. Haemodynamic parameters were compared between patients and correlated to the estimated glomerular filtration rate, DCE-MRI parameters (n = 10) and histopathology from allograft biopsies (n = 15). RESULTS: For inter-observer reproducibility, kappa was > 0.99 and 0.62 and CoV of flow was 12.6% and 7.8% for RA and RV, respectively. For test-retest repeatability, kappa was > 0.99 and 0.5 and CoV of flow was 27.3% and 59.4%, for RA and RV, respectively. RA (p = 0.039) and RV (p = 0.019) flow were both significantly reduced in dysfunctional allografts. Both identified chronic allograft dysfunction with good diagnostic performance (RA: AUC = 0.76, p = 0.036; RV: AUC = 0.8, p = 0.018). RA flow correlated negatively with histopathologic interstitial fibrosis score ci (ρ = - 0.6, p = 0.03). CONCLUSIONS: 4D flow parameters had better repeatability in the RA than in the RV. RA and RV flow can identify chronic renal allograft dysfunction, with RA flow correlating with histopathologic interstitial fibrosis score. KEY POINTS: • Inter-observer reproducibility of 4D flow measurements was acceptable in both the transplant renal artery and vein, but test-retest repeatability was better in the renal artery than in the renal vein. • Blood flow measurements obtained with 4D flow MRI in the renal artery and renal vein are significantly reduced in dysfunctional renal transplants. • Renal transplant artery flow correlated negatively with histopathologic interstitial fibrosis score.


Assuntos
Nefropatias/diagnóstico por imagem , Transplante de Rim , Adulto , Idoso , Biópsia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Taxa de Filtração Glomerular , Hemodinâmica , Humanos , Nefropatias/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
14.
Eur Radiol ; 31(12): 9306-9315, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34043055

RESUMO

OBJECTIVES: (1) To assess the quality of the arterial input function (AIF) during dynamic contrast-enhanced (DCE) MRI of the liver and (2) to quantify perfusion parameters of hepatocellular carcinoma (HCC) and liver parenchyma during the first 3 min post-contrast injection with DCE-MRI using gadoxetate disodium compared to gadobenate dimeglumine (Gd-BOPTA) in different patient populations. METHODS: In this prospective study, we evaluated 66 patients with 83 HCCs who underwent DCE-MRI, using gadoxetate disodium (group 1, n = 28) or Gd-BOPTA (group 2, n = 38). AIF qualitative and quantitative features were assessed. Perfusion parameters (based on the initial 3 min post-contrast) were extracted in tumours and liver parenchyma, including model-free parameters (time-to-peak enhancement (TTP), time-to-washout) and modelled parameters (arterial flow (Fa), portal venous flow (Fp), total flow (Ft), arterial fraction, mean transit time (MTT), distribution volume (DV)). In addition, lesion-to-liver contrast ratios (LLCRs) were measured. Fisher's exact tests and Mann-Whitney U tests were used to compare the two groups. RESULTS: AIF quality, modelled and model-free perfusion parameters in HCC were similar between the 2 groups (p = 0.054-0.932). Liver parenchymal flow was lower and liver enhancement occurred later in group 1 vs group 2 (Fp, p = 0.002; Ft, p = 0.001; TTP, MTT, all p < 0.001), while there were no significant differences in tumour LLCR (max. positive LLCR, p = 0.230; max. negative LLCR, p = 0.317). CONCLUSION: Gadoxetate disodium provides comparable AIF quality and HCC perfusion parameters compared to Gd-BOPTA during dynamic phases. Despite delayed and decreased liver enhancement with gadoxetate disodium, LLCRs were equivalent between contrast agents, indicating similar tumour conspicuity. KEY POINTS: • Arterial input function quality, modelled, and model-free dynamic parameters measured in hepatocellular carcinoma are similar in patients receiving gadoxetate disodium or gadobenate dimeglumine during the first 3 min post injection. • Gadoxetate disodium and gadobenate dimeglumine show similar lesion-to-liver contrast ratios during dynamic phases in patients with HCC. • There is lower portal and lower total hepatic flow and longer hepatic mean transit time and time-to-peak with gadoxetate disodium compared to gadobenate dimeglumine.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Compostos Organometálicos , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Perfusão , Estudos Prospectivos
15.
Kidney Int ; 97(2): 414-420, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31874802

RESUMO

Here we assessed the diagnostic value of a quantitative multiparametric magnetic resonance imaging (mpMRI) protocol for evaluation of renal allograft dysfunction with fibrosis. Twenty-seven renal transplant patients, including 15 with stable functional allografts (eGFR mean 71.5 ml/min/1.73m2), and 12 with chronic dysfunction/established fibrosis (eGFR mean 30.1 ml/min/1.73m2), were enrolled in this prospective single-center study. Sixteen of the patients had renal biopsy (mean 150 days) before the MRI. All patients underwent mpMRI at 1.5T including intravoxel-incoherent motion diffusion-weighted imaging, diffusion tensor imaging, blood oxygen level dependent (BOLD R2*) and T1 quantification. True diffusion D, pseudodiffusion D*, perfusion fraction PF, apparent diffusion coefficient (ADC), fractional anisotropy (FA), R2* and T1 were calculated for cortex and medulla. ΔT1 was calculated as (100x(T1 Cortex-T1 Medulla)/T1 Cortex). Test-retest repeatability and inter-observer reproducibility were assessed in four and ten patients, respectively. mpMRI parameters had substantial test-retest and interobserver repeatability (coefficient of variation under 15%), except for medullary PF and D* (coefficient of variation over 25%). Cortical ADC, D, medullary ADC and ΔT1 were all significantly decreased, while cortical T1 was significantly elevated in fibrotic allografts. Cortical T1 showed positive correlation to the Banff fibrosis and tubular atrophy scores. The combination of ΔT1 and cortical ADC had excellent cross-validated diagnostic performance for detection of chronic dysfunction with fibrosis. Cortical ADC and T1 had good performance for predicting eGFR decline at 18 months (4 or more ml/min/1.73m2/year). Thus, the combination of cortical ADC and T1 measurements shows promising results for the non-invasive assessment of renal allograft histology and outcomes.


Assuntos
Transplante de Rim , Imageamento por Ressonância Magnética Multiparamétrica , Imagem de Tensor de Difusão , Fibrose , Humanos , Transplante de Rim/efeitos adversos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
16.
J Magn Reson Imaging ; 52(3): 787-794, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32073207

RESUMO

BACKGROUND: There is a need for noninvasive methods for the diagnosis and monitoring of portal hypertension (PH). PURPOSE: To 1) assess the correlation of liver and spleen T1 and T1ρ measurements with portal pressures in patients with chronic liver disease, and 2) to compare the diagnostic performance of the relaxation parameters with radiological assessment of PH. STUDY TYPE: Prospective. SUBJECTS: Twenty-five patients (M/F 16/9, mean age 56 years, range 21-78 years) undergoing portal pressure (hepatic venous pressure gradient [HVPG]) measurements. FIELD STRENGTH/SEQUENCE: 1.5T abdominal MRI scan, including T1ρ and T1 mapping. ASSESSMENT: Liver and spleen T1ρ and T1 , radiological PH score, and (normalized) spleen length were evaluated. STATISTICAL TESTS: Spearman correlation of all MRI parameters with HVPG was assessed. The diagnostic performance of the assessed parameters for prediction of PH (HVPG ≥5 mmHg) and clinically significant PH (CSPH, HVPG ≥10 mmHg) was determined by receiver operating characteristic (ROC) analysis. RESULTS: The mean HVPG measurement was 7.8 ± 5.3 mmHg (PH, n = 18 [72%] including CSPH, n = 9 [36%]). PH score, (normalized) spleen length and spleen T1ρ significantly correlated with HVPG, with the strongest correlation found for spleen T1ρ (r = 0.613, P = 0.001). Spleen T1ρ was the only parameter that showed significant diagnostic performance for assessment of PH (area under the curve [AUC] 0.817, P = 0.015) and CSPH (AUC = 0.778, P = 0.024). Normalized spleen length also showed significant diagnostic performance for prediction of CSPH, with a slightly lower AUC (= 0.764, P = 0.031). The radiological PH score, T1ρ and T1 of the liver and T1 of the spleen, did not show significant diagnostic performance for assessment of CSPH (P > 0.075). DATA CONCLUSION: Spleen T1ρ showed a significant correlation with portal pressure and showed improved diagnostic performance for prediction of CSPH compared to radiological assessment. These initial results need confirmation in a larger cohort. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;52:787-794.


Assuntos
Técnicas de Imagem por Elasticidade , Hipertensão Portal , Adulto , Idoso , Biomarcadores , Humanos , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/patologia , Fígado/diagnóstico por imagem , Cirrose Hepática/patologia , Pessoa de Meia-Idade , Estudos Prospectivos , Baço/diagnóstico por imagem , Adulto Jovem
17.
MAGMA ; 33(1): 131-140, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31628564

RESUMO

PURPOSE: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. METHODS: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). RESULTS: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. CONCLUSION: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Nefrologia/normas , Pesquisa Translacional Biomédica/normas , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Europa (Continente) , Prova Pericial , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Padrões de Referência , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências , Estados Unidos
19.
MAGMA ; 33(1): 163-176, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31758418

RESUMO

To develop technical recommendations on the acquisition and post-processing of renal longitudinal (T1) and transverse (T2) relaxation time mapping. A multidisciplinary panel consisting of 18 experts in the field of renal T1 and T2 mapping participated in a consensus project, which was initiated by the European Cooperation in Science and Technology Action PARENCHIMA CA16103. Consensus recommendations were formulated using a two-step modified Delphi method. The first survey consisted of 56 items on T1 mapping, of which 4 reached the pre-defined consensus threshold of 75% or higher. The second survey was expanded to include both T1 and T2 mapping, and consisted of 54 items of which 32 reached consensus. Recommendations based were formulated on hardware, patient preparation, acquisition, analysis and reporting. Consensus-based technical recommendations for renal T1 and T2 mapping were formulated. However, there was considerable lack of consensus for renal T1 and particularly renal T2 mapping, to some extent surprising considering the long history of relaxometry in MRI, highlighting key knowledge gaps that require further work. This paper should be regarded as a first step in a long-term evidence-based iterative process towards ever increasing harmonization of scan protocols across sites, to ultimately facilitate clinical implementation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Pesquisa Translacional Biomédica/tendências , Consenso , Técnica Delphi , Humanos , Comunicação Interdisciplinar , Imageamento por Ressonância Magnética/instrumentação , Inquéritos e Questionários
20.
MAGMA ; 33(1): 177-195, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31676990

RESUMO

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Assuntos
Biomarcadores/metabolismo , Imagem de Difusão por Ressonância Magnética , Rim/diagnóstico por imagem , Pesquisa Translacional Biomédica , Algoritmos , Consenso , Técnica Delphi , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa